High Speed Fuses Ferrule Fuses Table of Contents Basic Catalog Number FWA FWX FWH FWC FWP FWK FWJ FWL/FWS Volts 150 250 500 600 690V/700 750 1000 1250/1500/2000 Amp Range 5-60 1-50 0.25-30 6-32 1-100 5-60 20-30 2-30 General Information Page 224-225 226-227 228-231 232-233 234-237 238-239 240-241 242 Accessories Fuse Holders Bussmann offers a full line of ferrule style (cylindrical clip-mounted) fuses, designed and tested to meet standards and requirements in various locations around the world. Their unique design and construction provide: • Superior cycling capability • Low energy let-through (I2t) Ferrule fuses provide an excellent solution for small UPS, small ac drives and other low power applications where space is at a premium. 241 Voltage Rating Ferrule Fuse Ranges Amps 5-60 1-50 0.25-30 6-32 20-100 1-50 5-60 20-30 20-30 8-15 2-6 AC X X X X X X X X X X X DC X X X X — X X X (800Vdc) X (1000Vdc) X (1000Vdc) X (1000Vdc) All Bussmann ferrule fuses — except 690V — have been tested at their rated voltage. The 690V ferrule fuse has been tested to the IEC 60269 standard, which requires clearing at the rated voltage +5%. Accessories Ferrule fuses may be mounted in fuseclips, fuse holders, fuse blocks or fused switches. A variety of products are available. Please consult Bussmann Application Engineering to discuss your requirement. For product data sheets, visit www.cooperbussmann.com/DatasheetsEle 223 High Speed Fuses Volts 150 250 500 600 700 (22 x 58mm) 700 (14 x 51mm) 750 1000 1250 1500 2000 High Speed Fuses Ferrule — FWP 690V/700V (IEC/UL): 1-50A, Striker Optional FWP (14 x 51mm) Arc Voltage Specifications Description: Ferrule style high speed fuses with and without indicating striker. Dimensions: See dimensions illustrations. Ratings: Volts: — 690Vac (IEC) — 700Vac (UL) FWP with — 800Vdc (5-50A) striker option. Amps: — 1-50A IR: — 200kA RMS Sym. — 50kA @800Vdc Agency Information: CE, UL Recognition JFHR2.E91958, CSA Component Acceptance file Class 1422-30, 1422-90 (53787) for versions without indicator only. Designed and tested to IEC 60269: Part 4. Electrical Characteristics Total Clearing I2t 1.4 1.2 1.0 0.9 0.8 0.7 0.6 This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of theapplied working voltage, Eg, (rms) at a power factor of 15%. 1.4 1.2 103 9 8 7 6 Power Losses 4 Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current. 3 UL 5 Eg 200 300 400 500 Catalog Numbers K Eg 300 400 500 600 700 1) 5-30A Range 2) 32-50A Range Dimensions - mm (in) Without Striker 50.8 (2.000") 14.3 (0.563") 15.5 (0.610") Catalog Numbers Without Striker FWP-1A14F FWP-2A14F FWP-2.5A14F FWP-3A14F FWP-4A14F FWP-5A14F FWP-10A14F FWP-15A14F FWP-20A14F FWP-25A14F FWP-30A14F FWP-32A14F FWP-40A14F FWP-50A14F With Striker* FWP-10A14FI FWP-15A14FI FWP-20A14FI FWP-25A14FI FWP-30A14FI FWP-32A14FI FWP-40A14FI FWP-50A14FI Size 0.4 0.3 0.2 Ib 30 40 50 60 70 80 90 100% Electrical Characteristics Rated I2t (A2 Sec) Current Minimum Clearing At Watts RMS-Amps Melting Rated Voltage Loss 14 x 51mm (9⁄16" x 2") 14 x 51mm (9⁄16” x 2”) 1 2 2.5 3 4 5 10 15 20 25 30 32 40 50 — — — — — 1.6 3.6 8.6 26.0 46.5 58 68 84 200 — — — — — 11.0 38.5 70 230 375 485 600 750 1800 — — — — — 1.5 4 5.5 6 7 9 7.6 8 9 10 15 20 25 30 32 40 50 3.6 8.6 26.0 46.5 58 68 84 200 38.5 70 230 375 485 600 750 1800 4 5.5 6 7 9 7.6 8 9 *Striker range is 600Vdc only • Watts loss provided at rated current. • See accessories on page 243. With Striker 59 (2.323") 51 (2.00") 14.3 (0.563") 5 (0.197") 13 (0.511") • • • • 700 0.6 0.5 0.1 The total clearing I2t at rated voltage and at power factor of 15% are given in 0.5 the electrical 1) characteristics. For other 0.4 2) voltages, the clearing I2t is 0.3 found by multiplying by 200 correction factor, K, given as a function of applied working voltage, Eg, (rms). 234 600 1.0 Kp 0.8 Features and Benefits Excellent cycling capability and DC performance Low arc voltage and low energy let-through (I2t) Low watts loss in a compact size Used with finger-safe holders/blocks Data Sheet: 720025 For product data sheets, visit www.cooperbussmann.com/DatasheetsEle High Speed Fuses Ferrule — FWP 690V/700V (IEC/UL): 1-50A, Striker Optional Without Striker FWP 5-50A: 660V/700V (14 x 51mm) Time-Current Curve 104 6 4 2 103 6 4 2 FWP-25A14F FWP-30A14F FWP-32A14F FWP-40A14F FWP-50A14F 102 Virtual Pre-Arcing Time In Seconds 6 4 2 101 6 4 2 100 6 4 FWP-5A14F FWP-10A14F FWP-15A14F FWP-20A14F 2 10–1 6 4 2 10–2 6 4 2 10–3 6 4 2 10–4 2 4 6 8 2 101 4 6 8 2 102 4 6 8 103 6 105 High Speed Fuses Prospective Current In Amps RMS Peak Let-Through Curve 104 FWP-50A14F FWP-40A14F FWP-32A14F FWP-30A14F FWP-25A14F 6 4 Peak Let-Through Current 2 103 6 4 2 FWP-20A14F FWP-15A14F FWP-10A14F FWP-5A14F 102 6 4 2 101 101 2 4 6 102 2 4 6 103 2 4 6 104 2 4 2 Prospective Short-Circuit Current Symmetrical RMS Data Sheet: 35785307 For product data sheets, visit www.cooperbussmann.com/DatasheetsEle 235