VersaLux TM A R C H I T E CT U R A L L I G H T I N G S E R I E S Fluorescent/ Point Source Slot Job Name: Fixture Type: T5 Fluorescent Slot, Regressed Lens with MR16 LED Open Aperture 6.2500" -T5 (6.3750" -T8) 6.2500" -T5 (6.3750" -T8) Acrylic Lens Regressed 1.25" MR16 LED Compartment Ceiling /Trim Options Plaster Flange Drywall Fellert Flange (All Ceilings) Flangeless Donn Fineline Armstrong Bolt TechZone 9/16 Superfine TechZone 15/16 Prelude TechZone 9/16 Interlude Decoustic Wood VAR6-____L6_____-_____T____ ____-____-____-W-____ # of MR16 # of MR16 LED Wattage Lamps LED Wattage # of Fluor Lamps in Cross Section # of Fluor in Cross Section Fluor Wattage Fluor Lamp Ballast Length Wattage Ballast Trim Options* Length Trim Options* (Specify below) Consult factory 1 1See E (Electronic) Std. 36" for Lamp to Configurations † 2 2 D (Dimming) 48" Transformer/Driver (Pages 2-3) compatability 3 60" † Specify Ballast (required) 72" 84" 96" Voltage Voltage P (Plaster) F (Flange) X (Flangeless) 1 (120V) 2 (277V) Custom (specify) *P=Plaster: For use with Drywall and Fellert. F=Flange: Suitable for all ceiling types. X=Flangeless: For use with Donn Fineline 9/16, Armstrong Bolt Slot 9/16, TechZone 9/16 Superfine, TechZone 15/16 Prelude, TechZone 9/16 Interlude, Decoustic and Wood. -Ambient temperature 100 °F. maximum -Integral electronic ballast(s), thermally protected and toroidal transformer(s) -Through branch wiring capable KERS UN I ON OR LL CE Electrical S P L AY & M I -Standard Lens: Frosted acrylic -Shiplapped lenses for sections longer than 96" -Fixtures fabricated to any length (Refer to Pages 2-3) -Continuous run length configurations with fully illuminated corners -Below ceiling access to ballast, transformer and wiring -Lenses: Specify on Page 4 -Occupancy sensor, daylight control module and EM pack -HVAC, fire sprinkler, surveillance or public address systems integration -Nippo, Feelux, or Lumilux Seamless lamping DIS Features Options (Consult factory) W Fixture Specifications Fluorescent slot with regressed lens and MR16 LED Finish: White (std), custom available open aperture. Weight: Approx. 8 lbs. per linear foot Ceiling Cutout: Refer to Pages 2-3 AN RI A L Description EOU S INDUST Photometry: Consult factory Mounting -Threaded rod, hanger wire or alternate mounting by others, consult factory All designs and scaled drawings shall remain the property of STARFIRE LIGHTING, INC., and may not be reproduced or transmitted without expressed written consent. STARFIRE LIGHTING, INC. reserves the right to make changes on approved designs to facilitate manufacturing methods to the extent that such changes do not compromise design integrity. Starfire Lighting, Inc. 7 Donna Drive, Wood-Ridge, NJ 07075 P: 201.438.9540 F: 201.438.9541 www.starfirelighting.com Rev.0415 Page 1 T5 Single Lamp Configurations VAR6 Job Name: 1 - Choose fixture configuration 2 - Select desired fluorescent lamp wattage Fixture Type: For fixture installation dimensions per trim type, follow formula below For single MR16 downlight configurations, consult factory. Custom configurations upon request. (1) 14W 36" (1) 24 (HO) 35.625" OAL (Trim/Housing) (1) 21W 48" (1) 39 (HO) 47.625" OAL (Trim/Housing) Plaster Furthest extent of tape-in flange Length: OAL + 1.5", Width: 7.125" Ceiling cut out Length: OAL + 0.125", Width: 5.75" Flange Furthest extent of overlap flange Length: OAL + 0.625", Width: 5.25" Ceiling cut out Length: OAL + 0.125", Width: 5.75" Flangeless Opening for Wood/Tile/Decoustic ceilings Length: OAL + 0.125", Width: 5.75" CTC Grid spacing for T-Grid/ATC systems Length: OAL + 0.375", Width: 6" Example: Flangeless 48" (Nom) VAR6 in Decoustic ceiling Length: 47.625" + 0.125" = 47.75" x 5.75" Wide (1) 28W 60" (1) 54 (HO) 59.625" OAL (Trim/Housing) (2) 21W 72" (2) 39 (HO) 71.625" OAL (Trim/Housing) (2) 14W 72" (2) 24 (HO) (1) 21W & (1) 28W 84" (1) 39 (HO) & (1) 54 (HO) 83.625" OAL (Trim/Housing) (2) 21W 84" (2) 39 (HO) (2) 28W 96" (2) 54 (HO) 95.625" OAL (Trim/Housing) (2) 21W 96" (2) 39 (HO) Starfire's patent pending EvenGlow™ system eliminates lamp/socket imaging and bright spots. Starfire Lighting, Inc. 7 Donna Drive, Wood-Ridge, NJ 07075 P: 201.438.9540 F: 201.438.9541 www.starfirelighting.com Rev.0415 Page 2 Double Lamp Configurations VAR6 1 - Choose fixture configuration 2 - Select desired fluorescent lamp wattage T5 Job Name: Fixture Type: For fixture installation dimensions per trim type, follow formula below For single MR16 downlight configurations, consult factory. Custom configurations upon request. (2) 14W 36" (2) 24 (HO) 35.625" OAL (Trim/Housing) (2) 21W 48" (2) 39 (HO) 47.625" OAL (Trim/Housing) Plaster Furthest extent of tape-in flange Length: OAL + 1.5", Width: 7.125" Ceiling cut out Length: OAL + 0.125", Width: 5.75" Flange Furthest extent of overlap flange Length: OAL + 0.625", Width: 5.25" Ceiling cut out Length: OAL + 0.125", Width: 5.75" Flangeless Opening for Wood/Tile/Decoustic ceilings Length: OAL + 0.125", Width: 5.75" CTC Grid spacing for T-Grid/ATC systems Length: OAL + 0.375", Width: 6" Example: Flangeless 48" (Nom) VAR6 in Decoustic ceiling Length: 47.625" + 0.125" = 47.75" x 5.75" Wide (2) 28W 60" (2) 54 (HO) 59.625" OAL (Trim/Housing) (4) 21W 72" (4) 39 (HO) 71.625" OAL (Trim/Housing) (4) 14W 72" (4) 24 (HO) (2) 21W & (2) 28W 84" (2) 39 (HO) & (2) 54 (HO) 83.625" OAL (Trim/Housing) (4) 21W 84" (4) 39 (HO) (4) 28W 96" (4) 54 (HO) 95.625" OAL (Trim/Housing) (4) 21W 96" (4) 39 (HO) Starfire's patent pending EvenGlow™ system eliminates lamp/socket imaging and bright spots. Starfire Lighting, Inc. 7 Donna Drive, Wood-Ridge, NJ 07075 P: 201.438.9540 F: 201.438.9541 www.starfirelighting.com Rev.0415 Page 3 T5 Fluorescent Slot, Regressed Lens with MR16 LED Open Aperture Job Name: Fixture Type: VAR6 Fluorescent Options Acrylic Lenses Frosted (2067-P95) Lens Efficiency Cat. No. 81% (standard) 2447-P95 47% 47P D-Glare, Hi-Def 93% DH For other lens options, consult factory. Starfire Lighting, Inc. 7 Donna Drive, Wood-Ridge, NJ 07075 P: 201.438.9540 F: 201.438.9541 www.starfirelighting.com Rev.0415 Page 4