Technical Data TD0EV00003E Effective January 2014 Supersedes February 2013 AC Level 2 commercial electric vehicle charging station Product family overview The electric vehicle (EV) revolution is here, and with it is also the need for a robust and accessible EV charging infrastructure. Eaton meets that need with a family of EV charging stations specifically designed for use in the places where people work, shop, and play. Eaton’s AC Level 2 charging stations are offered in configurations up to 70A, and provide a 4–6 hour charging range depending on battery size, making this design suitable for commercial or fleet installations. For more information about Eaton’s electric vehicle solutions, scan this QR Code. Product description The AC Level 2 charging station provides users with a robust, dependable solution to their EV charging needs. Designed to meet the most rigorous electrical and environmental standards, the charging station is housed in an attractive aluminum case and equipped with the industry standard SAE J1772 power connector mounted on a standard 23-foot cable. A series of six LED indicators gives users system status and feedback for ease of use. The Level 2 charging station is available as a wallmount or as a freestanding pedestal. It is designed to include a mounting provision for a customer-supplied 120 Vac receptacle for field installation upon commissioning. Notee: Wallmount shown. Pedestal configuration also available. The charging station can be applied as standalone or be configured with optional secure access control devices, point-of-sale systems, or enable networking. Eaton’s stations are able to be fieldretrofitted with these options to support your changing application needs. Standard features • • • • AC Level 2 charging—208 Vac or 240 Vac Field-upgradable for communications, payment, and access control NEMA 3R exterior housing Eaton’s standard one-year warranty on all electrical components and housing per Selling Policy 25-000 Standards compliance • • • • • • • SAE J1772 2010 EV conductive charge coupler NFPA 70 National Electrical Code, Article 625 Electric Vehicle Charging System UL 2231 personnel protection systems for EV charging circuits UL 2594 EV supply equipment (outline of investigation) UL 1998 software in programmable components CSA C22.2 No. 107.1 FCC compliant Technical Data TD0EV00003E AC Level 2 commercial electric vehicle charging station Effective January 2014 Table 1. Catalog Numbering System S B R 3 B X CC 00 00 Optional Accessories Product Family Communications b S = Charging station Station Type Enclosure R = NEMA 3R A = AC Level 2 wallmount B = AC Level 2 pedestal Cable Length 3 = 23 ft X = Basic hardwire (serial, Modbus® RTU) Continuous Ampere Rating a B = 30A C = 48A D = 70A 00 =No accessory CC =Credit card swipe— time-based CS =Credit card swipe— session-based RB =RFID—basic ML=Energy meter a Upstream breaker shall be sized in accordance with NFPA 70 National Electrical Code (NEC), Article 625.14 (USA) or Canadian Electrical Code (CEC) Part 1 Section 86 (Canada). b Refer to Communications Guide PA191003EN for more details. NNote: Sample catalog number configuration above shows a Level 2 Pedestal EVSE, NEMA 3R enclosure, 23-foot cable, 30A, with basic communications and a time-based credit card swipe. 2 eaton www.eaton.com Technical Data TD0EV00003E AC Level 2 commercial electric vehicle charging station Effective January 2014 Specifications Table 2. Technical Specifications (30A–70A Configurations) Table 4. I/O Specifications Description Description Incoming voltage and connections 208–240 Vac, Line 1, Line 2, and Earth ground Input frequency 50/60 Hz Output amperage—max. continuous 30A 48A 70A Interlocked power output Yes Overcurrent rating Output amperage +5% Ground fault interruption 20 mA (UL 2231-1 / UL 2231-2 personnel protection) Automatic reset after DIP switch selectable Enable/Disable nuisance trip feature (default Enabled) Cold-load pickup (randomized restart on Yes power failure/delay before charging resumes after a power failure) Mechanical operations 10,000 cycles (EV connector, replaceable) 100,000 cycles (contactor, replaceable) De-energization on breakaway Yes J1772 pistol-grip EV connector Permissive run contact Current control to vehicle RS-485 Field diagnostics and upgrade port Mounting Provision for 120 Vac receptacle Surge withstand Up to 6 kV at 3000A Soft start No—Field selectable (DIP switch) Table 3. Physical and Environmental Specifications Description Cable length Dimensions H x W x D in inches (mm) Weight unpackaged Weight packaged Status indicators Pushbuttons Ingress protection Wallmount Pedestal Available up to 23 feet a 22.00 x 15.00 x 8.00 53.00 x 15.00 x 8.00 (558.8 x 381.0 x 203.2) (1347.0 x 381.0 x 203.2) Add 9 inches below for cable hanger 50 lbs 95 lbs (includes skid) b Six LEDs: Power, Charging, Complete, Remotely Controlled, Temporary Fault, and Service Two buttons: Override and Reset IP14 Type rating Temperature—operating c Temperature—storage Humidity Wallmount Pedestal Same as output rating NC dry contact input 4–20 mA analog input Modbus RTU four-wire port RS-232 DB9 (Telnet support) Recommended: Cooper Wiring Devices by Eaton 20A receptacle with ground fault (COOPER VGF20GY) and NEMA 3R receptacle cover (GARVIN WPCV1GWIU) Table 5. Optional Specifications Description RFID basic Credit card processing Networking Wallmount Pedestal Basic lock/unlock with card or keyfob PCI-DSS Refer to Communications Guide PA191003EN Installation The electric requirements and wiring installation procedure for electric vehicle charging stations vary by form-factor, but can easily be performed by any qualified electrician. For the wallmount AC Level 2, the procedure is much like installing an electric stove circuit, and for the outside pedestal, it is much like installing a lighting bollard circuit. See installation guide IM0EV00002E for more details. For more information, visit www.eaton.com/plugin, call 855-ETN-EVSE (855-386-3873), or call your local Eaton sales office. 3R –30 to 50°C –40 to 70°C 90% RH, noncondensing a Consult factory for additional lengths. b Pedestal adds 10 lbs to weight. c 48A and 70A are 40°C maximum temperature. eaton www.eaton.com 3 Technical Data TD0EV00003E Effective January 2014 AC Level 2 commercial electric vehicle charging station Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Electrical Sector Canadian Operations 5050 Mainway Burlington, ON L7L 5Z1 Canada EatonCanada.ca © 2014 Eaton All Rights Reserved Printed in USA Publication No. TD0EV00003E / Z14458 January 2014 Eaton is a registered trademark. All other trademarks are property of their respective owners.