Ordering information AC-DC Power Supplies Enclosed type RMC15A RMC 15A 1 2 -1 3 -O 4 1Series name 2Output wattage 3Output voltage combination 4Optional *2 C :with Coating G :Low leakage current J :Connector type N :with Cover R RMC MODEL DC OUTPUT V1 V2 V3 RMC15A-1 +5V 2.0A +12V 0.3A -12V 0.2A RMC15A-2 +5V 2.0A +15V 0.2A -15V 0.2A RMC15A-1 AC85 - 132 1f or DC110 - 170 0.45typ (Io=100%) 47 - 440 or DC 65typ (Io=100%) 20typ (Io=100%) (At cold start) RMC15A-2 SPECIFICATIONS MODEL VOLTAGE[V] ACIN 100V CURRENT[A] FREQUENCY[Hz] INPUT EFFICIENCY[%] ACIN 100V INRUSH CURRENT[A] ACIN 100V VOLTAGE[V] CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +50C *1 RIPPLE[mVp-p] -10 - 0C *1 0 to +50C *1 RIPPLE NOISE[mVp-p] OUTPUT -10 - 0C *1 0 to +50C TEMPERATURE REGULATION[mV] -10 to +50C START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION PROTECTION OVERVOLTAGE PROTECTION CIRCUIT OPERATING INDICATION INPUT-OUTPUT INPUT-FG, COVER ISOLATION OUTPUT-FG, COVER OUTPUT-OUTPUT(V1-V2,V3) OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE ENVIRONMENT VIBRATION IMPACT SAFETY AND AGENCY APPROVALS NOISE REGULATIONS CONDUCTED NOISE CASE SIZE/WEIGHT OTHERS COOLING METHOD *1 *2 * * +5 +12 -12 +5 +15 -15 0 - 2.0 0 - 0.3 0 - 0.2 0 - 2.0 0 - 0.2 0 - 0.2 20max 48max 48max 20max 60max 60max 100max 120max 120max 100max 150max 150max 100max 120max 120max 100max 120max 120max 150max 160max 160max 150max 160max 160max 120max 150max 150max 120max 150max 150max 170max 180max 180max 170max 180max 180max 50max 350max 350max 50max 350max 350max 60max 420max 420max 60max 420max 420max 100max (ACIN 85V, Io=100%) 10typ (ACIN 85V, Io=100%, 0 to +50C) 20typ (ACIN 100V, Io=100%, 0 to +50C) 5.00 - 5.25 Fixed Fixed 5.00 - 5.25 Fixed Fixed 11.40 to 12.60 -11.40 to -12.60 14.25 to 15.74 -14.25 to -15.75 xx xx Works over 105% of rating and recovers automatically By zerer diode clamping (+5V only) LED (Green) AC2,000V 1minute, DC500V 50MWmin (At Room Temperature) AC2,000V 1minute, DC500V 50MWmin (At Room Temperature) AC500V 1minute, DC500V 50MWmin (At Room Temperature) AC100V 1minute, DC100V 10MWmin (At Room Temperature) -10 to +60C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, C-UL Complies with DEN-AN Complies with FCC-B, VCCI-B 28X80X100mm (WXHXD) /250g max (without cover) Convection Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101). Please contact us about safety approvals for the model with option. Series/Parallel operation with other model is not possible. When units are operated with chassis and cover, derating is required. RMC-2 RMC15A External view RMC Connector type Barrier strip type Performance data 13.0 5.2 12.0 5.0 Output Voltage -12V +5V ¡RISE TIME & FALL TIME (RMC15A-1) 60 50 +12V 11.0 40 4.8 Io=100% 10.0 4.6 9.0 4.4 30 20 Ripple 8.0 4.2 0 40 50 60 70 80 90 INPUT VOLTAGE +5V +12V -12V RIPPLE mVp-p OUTPUT VOLTAGE V ¡STATIC CHARACTERISTICS (RMC15A-1) 10 100 110 120 130 V 60Hz ¡OVERCURRENT CHARACTERISTICS (RMC15A-1) ¡DERATING CURVE RMC-3 Ordering information AC-DC Power Supplies Enclosed type RMC30A RMC 30A 1 2 -1 3 -O 4 1Series name 2Output wattage 3Output voltage combination 4Optional *2 G :Low leakage current J :Connector type N :with Cover R RMC MODEL DC OUTPUT V1 V2 V3 RMC30A-1 +5V 3.0A +12V 1.2A -12V 0.3A RMC30A-2 +5V 3.0A +15V 0.5A -15V 0.5A RMC30A-1 AC85 - 132 1f or DC110 - 170 0.9typ (Io=100%) 47 - 440 or DC 67typ (Io=100%) 30typ (Io=100%) (At cold start) RMC30A-2 SPECIFICATIONS MODEL VOLTAGE[V] ACIN 100V CURRENT[A] FREQUENCY[Hz] INPUT EFFICIENCY[%] ACIN 100V INRUSH CURRENT[A] ACIN 100V VOLTAGE[V] CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +50C *1 RIPPLE[mVp-p] -10 - 0C *1 0 to +50C *1 RIPPLE NOISE[mVp-p] OUTPUT -10 - 0C *1 0 to +50C TEMPERATURE REGULATION[mV] -10 to +50C START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION PROTECTION OVERVOLTAGE PROTECTION CIRCUIT OPERATING INDICATION INPUT-OUTPUT INPUT-FG, COVER ISOLATION OUTPUT-FG, COVER OUTPUT-OUTPUT(V1-V2,V3) OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE ENVIRONMENT VIBRATION IMPACT SAFETY AND AGENCY APPROVALS NOISE REGULATIONS CONDUCTED NOISE CASE SIZE/WEIGHT OTHERS COOLING METHOD *1 *2 * * +5 +12 -12 +5 +15 -15 0 - 3.0 0 - 1.2 0 - 0.3 0 - 3.0 0 - 0.5 0 - 0.5 20max 48max 48max 20max 60max 60max 100max 120max 150max 100max 120max 150max 100max 120max 120max 100max 120max 120max 150max 160max 160max 150max 160max 160max 120max 150max 150max 120max 150max 150max 170max 180max 180max 170max 180max 180max 50max 350max 350max 50max 350max 350max 60max 420max 420max 60max 420max 420max 100max (ACIN 85V, Io=100%) 10typ (ACIN 85V, Io=100%, 0 to +50C) 20typ (ACIN 100V, Io=100%, 0 to +50C) 5.00 - 5.25 Fixed Fixed 5.00 - 5.25 Fixed Fixed 11.40 to 12.60 -11.40 to -12.60 14.25 to 15.75 -14.25 to -15.75 xx xx Works over 105% of rating and recovers automatically Works at 115 - 140% of rating (+5V) LED (Green) AC2,000V 1minute, DC500V 50MWmin (At Room Temperature) AC2,000V 1minute, DC500V 50MWmin (At Room Temperature) AC500V 1minute, DC500V 50MWmin (At Room Temperature) AC100V 1minute, DC100V 10MWmin (At Room Temperature) -10 to +60C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, C-UL Complies with DEN-AN Complies with FCC-B, VCCI-B 31X80X135mm (WXHXD)/350g max (without cover) Convection Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101). Please contact us about safety approvals for the model with option. Series/Parallel operation with other model is not possible. When units are operated with chassis and cover, derating is required. RMC-4 RMC30A External view RMC Connector type Barrier strip type Performance data ¡STATIC CHARACTERISTICS (RMC30A-1) ¡RISE TIME & FALL TIME (RMC30A-1) ¡OVERCURRENT CHARACTERISTICS (RMC30A-1) ¡DERATING CURVE RMC-5 Ordering information AC-DC Power Supplies Enclosed type RMC50A RMC 50A 1 2 -1 3 -O 4 1Series name 2Output wattage 3Output voltage combination 4Optional *3 C :with Coating G :Low leakage current J :Connector type N :with Cover R RMC MODEL DC OUTPUT V1 V2 V3 RMC50A-1 +5V 5.0A +12V 1.5(Peak 2)A -12V 0.5A RMC50A-2 +5V 5.0A +15V 1.2A -15V 0.5A RMC50A-1 AC85 - 132 1f or DC110 - 170 1.5typ (Io=100%) 47 - 440 or DC 70typ (Io=100%) 30typ (Io=100%) (At cold start) RMC50A-2 SPECIFICATIONS MODEL VOLTAGE[V] ACIN 100V CURRENT[A] FREQUENCY[Hz] INPUT EFFICIENCY[%] ACIN 100V INRUSH CURRENT[A] ACIN 100V VOLTAGE[V] *1 CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +50C *2 RIPPLE[mVp-p] -10 - 0C *2 0 to +50C *2 RIPPLE NOISE[mVp-p] OUTPUT -10 - 0C *2 0 to +50C TEMPERATURE REGULATION[mV] -10 to +50C START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION PROTECTION OVERVOLTAGE PROTECTION CIRCUIT OPERATING INDICATION INPUT-OUTPUT INPUT-FG, COVER ISOLATION OUTPUT-FG, COVER OUTPUT-OUTPUT(V1-V2,V3) OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE ENVIRONMENT VIBRATION IMPACT SAFETY AND AGENCY APPROVALS NOISE REGULATIONS CONDUCTED NOISE CASE SIZE/WEIGHT OTHERS COOLING METHOD *1 *2 *3 * * +5 +12 -12 +5 +15 -15 0 - 5.0 0 - 1.5 (Peak 2) 0 - 0.5 0 - 5.0 0 - 1.2 0 - 0.5 20max 48max 48max 20max 60max 60max 40max 150max 150max 40max 150max 150max 80max 120max 120max 80max 120max 120max 140max 160max 160max 140max 160max 160max 120max 150max 150max 120max 150max 150max 160max 180max 180max 160max 180max 180max 50max 350max 350max 50max 350max 350max 60max 420max 420max 60max 420max 420max 100max (ACIN 85V, Io=100%) 10typ (ACIN 85V, Io=100%, 0 to +50C) 20typ (ACIN 100V, Io=100%, 0 to +50C) 5.00 - 5.25 Fixed Fixed 5.00 - 5.25 Fixed Fixed 11.40 to 12.60 -11.40 to -12.60 14.25 to 15.75 -14.25 to -15.75 xx xx Works over 105% of rating and recovers automatically Works at 115 - 140% of rating (+5V) LED (Green) AC2,000V 1minute, DC500V 50MWmin (At Room Temperature) AC2,000V 1minute, DC500V 50MWmin (At Room Temperature) AC500V 1minute, DC500V 50MWmin (At Room Temperature) AC100V 1minute, DC100V 10MWmin (At Room Temperature) -10 to +65C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, C-UL Complies with DEN-AN Complies with FCC-B, VCCI-B 31X93X155mm (WXHXD) /350g max (without cover) Convection Peak load current of V2 for RMC50A-1 is possible to draw 30 seconds. Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101). Please contact us about safety approvals for the model with option. Series/Parallel operation with other model is not possible. When units are operated with chassis and cover, derating is required. RMC-6 RMC50A External view RMC Connector type Barrier strip type Performance data ¡STATIC CHARACTERISTICS (RMC50A-1) ¡RISE TIME & FALL TIME (RMC50A-1) ¡OVERCURRENT CHARACTERISTICS (RMC50A-1) ¡DERATING CURVE RMC-7