Specifications

advertisement
Ordering information
AC-DC Power Supplies Enclosed type
RMC15A
RMC 15A
1
2
-1
3
-O
4
1Series name
2Output wattage
3Output voltage combination
4Optional *2
C :with Coating
G :Low leakage current
J :Connector type
N :with Cover
R
RMC
MODEL
DC OUTPUT
V1
V2
V3
RMC15A-1
+5V 2.0A
+12V 0.3A
-12V 0.2A
RMC15A-2
+5V 2.0A
+15V 0.2A
-15V 0.2A
RMC15A-1
AC85 - 132 1f or DC110 - 170
0.45typ (Io=100%)
47 - 440 or DC
65typ (Io=100%)
20typ (Io=100%) (At cold start)
RMC15A-2
SPECIFICATIONS
MODEL
VOLTAGE[V]
ACIN 100V
CURRENT[A]
FREQUENCY[Hz]
INPUT
EFFICIENCY[%] ACIN 100V
INRUSH CURRENT[A] ACIN 100V
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +50C *1
RIPPLE[mVp-p]
-10 - 0C *1
0 to +50C *1
RIPPLE NOISE[mVp-p]
OUTPUT
-10 - 0C *1
0 to +50C
TEMPERATURE REGULATION[mV]
-10 to +50C
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
PROTECTION
OVERVOLTAGE PROTECTION
CIRCUIT
OPERATING INDICATION
INPUT-OUTPUT
INPUT-FG, COVER
ISOLATION
OUTPUT-FG, COVER
OUTPUT-OUTPUT(V1-V2,V3)
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
ENVIRONMENT
VIBRATION
IMPACT
SAFETY AND AGENCY APPROVALS
NOISE
REGULATIONS CONDUCTED NOISE
CASE SIZE/WEIGHT
OTHERS
COOLING METHOD
*1
*2
*
*
+5
+12
-12
+5
+15
-15
0 - 2.0
0 - 0.3
0 - 0.2
0 - 2.0
0 - 0.2
0 - 0.2
20max
48max
48max
20max
60max
60max
100max
120max
120max
100max
150max
150max
100max
120max
120max
100max
120max
120max
150max
160max
160max
150max
160max
160max
120max
150max
150max
120max
150max
150max
170max
180max
180max
170max
180max
180max
50max
350max
350max
50max
350max
350max
60max
420max
420max
60max
420max
420max
100max (ACIN 85V, Io=100%)
10typ (ACIN 85V, Io=100%, 0 to +50C) 20typ (ACIN 100V, Io=100%, 0 to +50C)
5.00 - 5.25
Fixed
Fixed
5.00 - 5.25
Fixed
Fixed
11.40
to
12.60
-11.40
to
-12.60
14.25
to
15.74
-14.25
to -15.75
xx
xx
Works over 105% of rating and recovers automatically
By zerer diode clamping (+5V only)
LED (Green)
AC2,000V 1minute, DC500V 50MWmin (At Room Temperature)
AC2,000V 1minute, DC500V 50MWmin (At Room Temperature)
AC500V 1minute, DC500V 50MWmin (At Room Temperature)
AC100V 1minute, DC100V 10MWmin (At Room Temperature)
-10 to +60C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL Complies with DEN-AN
Complies with FCC-B, VCCI-B
28X80X100mm (WXHXD) /250g max (without cover)
Convection
Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101).
Please contact us about safety approvals for the model with option.
Series/Parallel operation with other model is not possible.
When units are operated with chassis and cover, derating is required.
RMC-2
RMC15A
External view
RMC
Connector type
Barrier strip type
Performance data
13.0
5.2
12.0
5.0
Output Voltage
-12V
+5V
¡RISE TIME & FALL TIME (RMC15A-1)
60
50
+12V
11.0
40
4.8
Io=100%
10.0
4.6
9.0
4.4
30
20
Ripple
8.0
4.2
0
40
50
60
70
80
90
INPUT VOLTAGE
+5V
+12V
-12V
RIPPLE mVp-p
OUTPUT VOLTAGE V
¡STATIC CHARACTERISTICS (RMC15A-1)
10
100 110 120 130
V 60Hz
¡OVERCURRENT CHARACTERISTICS (RMC15A-1)
¡DERATING CURVE
RMC-3
Ordering information
AC-DC Power Supplies Enclosed type
RMC30A
RMC 30A
1
2
-1
3
-O
4
1Series name
2Output wattage
3Output voltage combination
4Optional *2
G :Low leakage current
J :Connector type
N :with Cover
R
RMC
MODEL
DC OUTPUT
V1
V2
V3
RMC30A-1
+5V 3.0A
+12V 1.2A
-12V 0.3A
RMC30A-2
+5V 3.0A
+15V 0.5A
-15V 0.5A
RMC30A-1
AC85 - 132 1f or DC110 - 170
0.9typ (Io=100%)
47 - 440 or DC
67typ (Io=100%)
30typ (Io=100%) (At cold start)
RMC30A-2
SPECIFICATIONS
MODEL
VOLTAGE[V]
ACIN 100V
CURRENT[A]
FREQUENCY[Hz]
INPUT
EFFICIENCY[%] ACIN 100V
INRUSH CURRENT[A] ACIN 100V
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +50C *1
RIPPLE[mVp-p]
-10 - 0C *1
0 to +50C *1
RIPPLE NOISE[mVp-p]
OUTPUT
-10 - 0C *1
0 to +50C
TEMPERATURE REGULATION[mV]
-10 to +50C
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
PROTECTION
OVERVOLTAGE PROTECTION
CIRCUIT
OPERATING INDICATION
INPUT-OUTPUT
INPUT-FG, COVER
ISOLATION
OUTPUT-FG, COVER
OUTPUT-OUTPUT(V1-V2,V3)
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
ENVIRONMENT
VIBRATION
IMPACT
SAFETY AND AGENCY APPROVALS
NOISE
REGULATIONS CONDUCTED NOISE
CASE SIZE/WEIGHT
OTHERS
COOLING METHOD
*1
*2
*
*
+5
+12
-12
+5
+15
-15
0 - 3.0
0 - 1.2
0 - 0.3
0 - 3.0
0 - 0.5
0 - 0.5
20max
48max
48max
20max
60max
60max
100max
120max
150max
100max
120max
150max
100max
120max
120max
100max
120max
120max
150max
160max
160max
150max
160max
160max
120max
150max
150max
120max
150max
150max
170max
180max
180max
170max
180max
180max
50max
350max
350max
50max
350max
350max
60max
420max
420max
60max
420max
420max
100max (ACIN 85V, Io=100%)
10typ (ACIN 85V, Io=100%, 0 to +50C) 20typ (ACIN 100V, Io=100%, 0 to +50C)
5.00 - 5.25
Fixed
Fixed
5.00 - 5.25
Fixed
Fixed
11.40
to
12.60
-11.40
to
-12.60
14.25
to
15.75
-14.25
to -15.75
xx
xx
Works over 105% of rating and recovers automatically
Works at 115 - 140% of rating (+5V)
LED (Green)
AC2,000V 1minute, DC500V 50MWmin (At Room Temperature)
AC2,000V 1minute, DC500V 50MWmin (At Room Temperature)
AC500V 1minute, DC500V 50MWmin (At Room Temperature)
AC100V 1minute, DC100V 10MWmin (At Room Temperature)
-10 to +60C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL Complies with DEN-AN
Complies with FCC-B, VCCI-B
31X80X135mm (WXHXD)/350g max (without cover)
Convection
Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101).
Please contact us about safety approvals for the model with option.
Series/Parallel operation with other model is not possible.
When units are operated with chassis and cover, derating is required.
RMC-4
RMC30A
External view
RMC
Connector type
Barrier strip type
Performance data
¡STATIC CHARACTERISTICS (RMC30A-1)
¡RISE TIME & FALL TIME (RMC30A-1)
¡OVERCURRENT CHARACTERISTICS (RMC30A-1)
¡DERATING CURVE
RMC-5
Ordering information
AC-DC Power Supplies Enclosed type
RMC50A
RMC 50A
1
2
-1
3
-O
4
1Series name
2Output wattage
3Output voltage combination
4Optional *3
C :with Coating
G :Low leakage current
J :Connector type
N :with Cover
R
RMC
MODEL
DC OUTPUT
V1
V2
V3
RMC50A-1
+5V 5.0A
+12V 1.5(Peak 2)A
-12V 0.5A
RMC50A-2
+5V 5.0A
+15V 1.2A
-15V 0.5A
RMC50A-1
AC85 - 132 1f or DC110 - 170
1.5typ (Io=100%)
47 - 440 or DC
70typ (Io=100%)
30typ (Io=100%) (At cold start)
RMC50A-2
SPECIFICATIONS
MODEL
VOLTAGE[V]
ACIN 100V
CURRENT[A]
FREQUENCY[Hz]
INPUT
EFFICIENCY[%] ACIN 100V
INRUSH CURRENT[A] ACIN 100V
VOLTAGE[V]
*1
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +50C *2
RIPPLE[mVp-p]
-10 - 0C *2
0 to +50C *2
RIPPLE NOISE[mVp-p]
OUTPUT
-10 - 0C *2
0 to +50C
TEMPERATURE REGULATION[mV]
-10 to +50C
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
PROTECTION
OVERVOLTAGE PROTECTION
CIRCUIT
OPERATING INDICATION
INPUT-OUTPUT
INPUT-FG, COVER
ISOLATION
OUTPUT-FG, COVER
OUTPUT-OUTPUT(V1-V2,V3)
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
ENVIRONMENT
VIBRATION
IMPACT
SAFETY AND AGENCY APPROVALS
NOISE
REGULATIONS CONDUCTED NOISE
CASE SIZE/WEIGHT
OTHERS
COOLING METHOD
*1
*2
*3
*
*
+5
+12
-12
+5
+15
-15
0 - 5.0
0 - 1.5 (Peak 2) 0 - 0.5
0 - 5.0
0 - 1.2
0 - 0.5
20max
48max
48max
20max
60max
60max
40max
150max
150max
40max
150max
150max
80max
120max
120max
80max
120max
120max
140max
160max
160max
140max
160max
160max
120max
150max
150max
120max
150max
150max
160max
180max
180max
160max
180max
180max
50max
350max
350max
50max
350max
350max
60max
420max
420max
60max
420max
420max
100max (ACIN 85V, Io=100%)
10typ (ACIN 85V, Io=100%, 0 to +50C) 20typ (ACIN 100V, Io=100%, 0 to +50C)
5.00 - 5.25
Fixed
Fixed
5.00 - 5.25
Fixed
Fixed
11.40
to
12.60
-11.40
to
-12.60
14.25
to
15.75
-14.25
to -15.75
xx
xx
Works over 105% of rating and recovers automatically
Works at 115 - 140% of rating (+5V)
LED (Green)
AC2,000V 1minute, DC500V 50MWmin (At Room Temperature)
AC2,000V 1minute, DC500V 50MWmin (At Room Temperature)
AC500V 1minute, DC500V 50MWmin (At Room Temperature)
AC100V 1minute, DC100V 10MWmin (At Room Temperature)
-10 to +65C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL Complies with DEN-AN
Complies with FCC-B, VCCI-B
31X93X155mm (WXHXD) /350g max (without cover)
Convection
Peak load current of V2 for RMC50A-1 is possible to draw 30 seconds.
Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101).
Please contact us about safety approvals for the model with option.
Series/Parallel operation with other model is not possible.
When units are operated with chassis and cover, derating is required.
RMC-6
RMC50A
External view
RMC
Connector type
Barrier strip type
Performance data
¡STATIC CHARACTERISTICS (RMC50A-1)
¡RISE TIME & FALL TIME (RMC50A-1)
¡OVERCURRENT CHARACTERISTICS (RMC50A-1)
¡DERATING CURVE
RMC-7
Download