Contents 0 6 - Pendant control stations and controllers Pendant control stations with intuitive operation Selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6/2 b Double insulated, for control circuits v Complete stations “ready for use”, “Pistol grip”, type XAC A . . . . . . . . page 6/5 v Complete stations “ready for use”, type XAC D . . . . . . . . . . . . . . . . . page 6/9 b Double insulated, for power circuits (direct switching) v Complete stations “ready for use”, type XAC D . . . . . . . . . . . . . . . . .page 6/11 b Double insulated, for control or power circuits v Empty enclosures, type XAC D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6/12 v Separate components and spare parts . . . . . . . . . . . . . . . . . . . . . . . . . page 6/12 . . . . . . . . . . . . page 6/17 v Variable composition stations, factory assembled Pendant control stations Selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6/2 b Double insulated, type XAC A, for control circuits v v v v Complete stations “ready for use” . . . . . . . . . . . . . . . . . . . . . . . . . . . Empty enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Separate components and spare parts . . . . . . . . . . . . . . . . . . . . . . . Variable composition stations, factory assembled ............ page 6/19 page 6/23 page 6/24 page 6/33 b Double insulated, type XAC B or metal, type XAC M (1) v v v v v v 6 Complete stations “ready for use”, type XAC B, for control circuits . . Complete stations “ready for use”, type XAC B, for power circuits . . . Empty enclosures, type XAC B, for control or power circuits . . . . . . . Empty enclosures, type XAC B or XAC M, for control circuits . . . . . . . Separate components and spare parts . . . . . . . . . . . . . . . . . . . . . . . Variable composition stations, factory assembled . . . . . . . . . . . . . . . page 6/35 page 6/37 page 6/39 page 6/41 page 6/42 page 6/59 b Double insulated, type XAC F, for control circuits (1) v Empty enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6/61 v Variable composition stations, factory assembled . . . . . . . . . . . . . . . page 6/65 (1) XAC M and XAC F: products for maintenance purposes only. 6/0 Controllers Selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6/66 b Controllers for “light hoisting” applications, type XKB v Controllers XKB A with predefined, non modifiable schemes, factory assembled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6/72 v Controllers XKB E with variable composition schemes, factory assembled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6/72 v Separate components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6/75 1 2 b Controllers for “medium hoisting” applications, type XKD F v Controllers with variable composition schemes, factory assembled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6/78 v Separate components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6/83 b Controllers for “heavy hoisting” applications, type XKM v Controllers XKM A and XKM B with variable composition schemes, factory assembled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6/86 v Controllers XKM C with variable composition schemes, factory assembled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6/93 v Separate components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6/95 3 4 b Potentiometers for controllers v For standard applications, type XKZ A . . . . . . . . . . . . . . . . . . . . . . . page 6/100 v For applications requiring an extended “neutral zone”, types XKB Z and XKD Z . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6/101 5 6 7 8 9 10 6/1 Selection guide 6 Pendant control stations 6 Complete stations “ready for use” and variable composition stations Complete stations “ready for use” 1 Applications Control circuits Simple hoisting: 1 movement Handling-hoisting: 2 movements Motor control Single-speed 2 2-speed Emergency stop 3 4 5 6 Number of operators 2 Enclosure material Pendant station type reference Page(s) 1 2 2 (2-directional) Polypropylene Polypropylene Polypropylene Polyester 4 4 Polypropylene Polyester XAC A XAC D XAC A XAC B XAC A XAC B 6/5 6/9 6/19 6/35 6/20 6/35 Variable composition stations Applications Number of cut-outs Control circuits 1 or 2 Equipment b Emergency stop (front mounted) b Contact blocks for 1 or 2 speeds Enclosure material Pendant station type reference Page(s) 2, 3, 4, 5, 6, 8 or 12 2, 3, 4, 6, 8 or 12 in 1 row or 2 rows of 6 b b b b Polypropylene Pushbuttons Selector/key switches Pilot lights Emergency stop (front or base mounted) b Wobblesticks b Contact blocks for 1 or 2 speeds Polypropylene Pushbuttons Selector/key switches Pilot lights Emergency stop (front or base mounted) b Wobblesticks b Contact blocks for 1 or 2 speeds Polyester XAC D XAC A XAC B 6/12 and 6/13 6/23 to 6/29 6/39 to 6/54 7 8 9 10 6/2 b b b b 6 6 Power circuits Simple hoisting: 1 movement Handling-hoisting: 3 movements Handling-hoisting: 2 movements 3 movements 1 2 3 4 6 6 8 8 Polypropylene Polyester Polypropylene XAC A XAC B 6/20 6/35 4 or 8 2 4 6 Polyester 1 (2-directional) Polypropylene Polyester Polyester Polyester XAC A XAC B XAC D XAC B XAC B XAC B 6/21 6/35 6/11 6/37 6/37 6/38 Up to 30 Power circuits 1 or 2 5 6 2, 3, 4, 6, 8 or 12 in 2 rows of 6 Products for maintenance purposes only Products for maintenance purposes only 7 8 b b b b Pushbuttons Selector/key switches Pilot lights Emergency stop (front or base mounted) b Wobblesticks b Contact blocks for 1 or 2 speeds b b b b Pushbuttons Selector/key switches Pilot lights Emergency stop (front or base mounted) b Wobblesticks b Contact blocks for 1 or 2 speeds b Emergency stop (front mounted) b Contact blocks for 1 or 2 speeds b b b b Aluminium Polyester Polypropylene Polyester XAC M XAC F XAC D XAC B 6/41 6/61 6/12 and 6/13 6/37 to 6/54 Pushbuttons Selector/key switches Pilot lights Emergency stop (front or base mounted) b Wobblesticks b Contact blocks for 1 or 2 speeds 9 10 6/3 Characteristics 6 Pendant control stations 6 Double insulated with intuitive operation, type XAC A “Pistol grip” For control circuits Environment 1 Conformity to standards EN/IEC 60947-5-1 EN/IEC 60204-32, UL 508, CSA C22-2 n° 14 EN/IEC 60947-5-5 and EN/ISO 13850: 2006 for versions with trigger action Emergency stop UL type 4X A600-Q600, CSA type 4 A600-Q600 Product certifications 2 3 Protective treatment Standard version Ambient air temperature For operation For storage “TH” °C °C Vibration resistance - 25…+ 70 - 40…+ 70 15 gn (10…500 Hz) conforming to IEC 60068-2-6 Shock resistance 100 gn conforming to IEC 60068-2-27 Electric shock protection Class II conforming to IEC 61140 Degree of protection IP 65 conforming to IEC 60529 IK 08 conforming to EN 50102 1 Mechanical durability (in millions of operating cycles) Enclosure Double insulated polypropylene, coloured yellow throughout Cable entry 4 Rubber sleeve with stepped entry diameter for cable Ø 7…Ø 15 mm Contact block characteristics Rated operational characteristics 5 Thermal current (lthe) A a AC-15: A600 or Ue = 600 V, le = 1.2 A or Ue = 240 V, Ie = 3 A c DC-13: Q600 or Ue = 600 V, le = 0.1 A or Ue = 250 V, Ie = 0.27 A conforming to EN/IEC 60947-5-1 Appendix A 10 Rated insulation voltage (Ui) V 600, degree of pollution 3, conforming to IEC 60947-1 Rated impulse withstand voltage (U imp) kV 6, conforming to IEC 60947-1 Positive operation Mushroom head pushbutton: N/C contact with positive opening operation conforming to EN/IEC 60947-5-1 Appendix K Slow break Contact operation 6 7 Resistance across terminals MΩ y 25 Operating force N 13 to 15 Terminal referencing By numbers conforming to CENELEC EN 50013 Short-circuit protection 10 A cartridge fuse type gG (gl) Connection mm2 Screw and captive cable clamp terminals. Clamping capacity: 1 x 2.5 or 2 x 1.5 with or without cable end Conforming to EN/IEC 60947-5-1 Appendix C. Utilisation categories AC-15 and DC-13. Operating rate: 3600 operating cycles/hour. Load factor: 0.5. Rated operational power d.c. supply c Power broken in W for 1 million operating cycles a.c. supply a 50/60 Hz o Inductive circuit Millions of operating cycles 8 9 1 Ithe 0,6 230 V 127 V 0,4 24...48 V 0,2 0,1 1 2 10 References: pages 6/5 and 6/6 6/4 Dimensions: page 6/7 Application schemes: page 6/7 4 6 Current in A 10 Voltage V W o 24 65 48 48 120 40 References 6 Pendant control stations 6 Double insulated with intuitive operation, type XAC A “Pistol grip” For control circuits Complete stations “ready for use” For control of single-speed hoist motors 2 mechanically interlocked Standard Contact block(s) and scheme Per direction For Emergency stop 1 N/O – ZB2 BE101 Reference 13 Type of operators XAC A201 Weight kg 0.270 XAC A205 0.300 1 11 13 1 N/O ZB2 BE101 – 2 – XAC A211 0.290 – XAC A215 0.320 1 N/C ZB2 BE102 XAC A2014 0.310 XAC A2054 0.340 XAC A2114 0.310 XAC A2154 0.340 11 13 12 1 N/C + 1 N/O ZB2 BE102 + ZB2 BE101 XAC A2114 14 XAC A2014 11 11 12 11 12 4 12 1 N/C ZB2 BE102 1 N/C ZB2 BE102 11 1 N/O ZB2 BE101 1 N/C ZB2 BE102 3 5 12 11 13 13 14 11 13 12 14 1 N/C + 1 N/O ZB2 BE102 + ZB2 BE101 14 Booted 1 N/O ZB2 BE101 13 2 Standard mechanically interlocked + 1 trigger action latching Emergency stop Ø 30 mm operator ZA2 BS834 (1) 12 1 N/C + 1 N/O ZB2 BE102 + ZB2 BE101 XAC A211 DF565518 DF565517 XAC A201 14 14 Booted 12 1 N/C + 1 N/O ZB2 BE102 + ZB2 BE101 14 14 Number of operators 13 DF565516 DF565515 Functions 6 (1) Trigger action mechanically latching Emergency stop pushbuttons conform to standards EN/IEC 60204-32, EN/ISO 13850: 2006, Machinery directive 98/37/EC and standard EN/IEC 60947-5-5. 7 8 9 10 Characteristics: page 6/4 Dimensions: page 6/7 Application schemes: page 6/7 6/5 References 6 Pendant control stations 6 Double insulated with intuitive operation, type XAC A “Pistol grip” For control circuits Complete stations “ready for use” For control of 2-speed hoist motors Standard Reference XAC A207 Weight kg 0.320 2 step 1 N/O + 1 N/O staggered ZB2 BE101 + ZB2 BE201 – XAC A217 0.320 1 N/C ZB2 BE102 XAC A2074 0.360 XAC A2174 0.360 23 2 mechanically interlocked Contact block(s) and scheme Per direction For Emergency stop 2 step – 1 N/O + 1 N/O staggered ZB2 BE101 + ZB2 BE201 24 Type of operators 13 DF565519 DF565520 Number of operators 14 Functions 1 XAC A2074 23 24 23 24 11 13 12 11 1 N/C ZB2 BE102 12 5 2 step 1 N/O + 1 N/O staggered ZB2 BE101 + ZB2 BE201 23 Booted 24 4 2 step 1 N/O + 1 N/O staggered ZB2 BE101 + ZB2 BE201 13 DF565522 2 Standard mechanically interlocked + 1 trigger action latching Emergency stop Ø 30 mm operator ZA2 BS834 (1) 14 XAC A217 DF565521 XAC A207 14 3 13 Booted 14 2 XAC A2174 Separate components and spare parts Description 6 803990 803998 7 10 Scheme Reference – XAC A921 Weight kg 0.010 – XAC A922 0.010 – XAC A923 0.010 – XAC A924 0.010 N/O ZB2 BE101 0.015 N/C ZB2 BE102 0.015 ZB2 BE201 0.015 XAC A913 0.070 XAC A923 ZB2 BEppp Contact blocks spring return, slow break XAC A all models ●1 530667 XAC A217p (2-speed) ●2 9 XAC A921 Marking/ Function XAC A211p XAC A215p (single-speed) 530668 8 Booted pushbutton operators with fixing screws For use with N/O staggered Protective cable sleeve + suspension ring + cable clamp XAC A913 Characteristics: page 6/4 6/6 Cable Ø 7 to Ø 13 mm – – (1) Trigger action mechanically latching Emergency stop pushbuttons conform to standards EN/IEC 60204-32, EN/ISO 13850: 2006, Machinery directive 98/37/EC and standard EN/IEC 60947-5-5. Dimensions: page 6/7 Application schemes: page 6/7 Pendant control stations Dimensions, application schemes 6 6 Double insulated with intuitive operation, type XAC A “Pistol grip” For control circuits Complete stations “ready for use” Dimensions XAC A2pp XAC A2ppp internal Ø internal Ø 7...9 9...11 7...9 9...11 11...13 13...15 11...13 13...15 1 45,5 3 235 235 295 295 2 4 39 52 71 39 52 45,5 101 (1) 5 (1) With trigger action latching Ø 30 mm Emergency stop ZA2 BS834. Application schemes (typical examples) For control of single-speed reversing motor XAC A2p5p 6 11 13 12 – S1 14 13 12 12 11 11 XAC A2p1p 14 – S1 – KM1 A2 A1 – KM2 A2 – KM1 A2 – KM2 A1 A1 A1 14 – S2 A2 11 13 12 – S2 14 13 7 8 For control of 2-speed reversing motor 9 23 13 12 11 XAC A2p7p 24 23 13 14 – S1 Characteristics: page 6/4 24 A1 10 A2 – KM1 A2 – KM A2 – KM2 A1 A1 14 – S2 References: pages 6/5 and 6/6 6/7 Characteristics 6 Pendant control stations 6 Double insulated with intuitive operation, type XAC D For control circuits Environment 1 2 3 4 Conformity to standards EN/IEC 60947-5-1 EN/IEC 60204-32, UL 508, CSA C22-2 n° 14 EN/IEC 60947-5-5 and EN/ISO 13850: 2006 for versions with trigger action Emergency stop Protective treatment Standard version “TH” Ambient air temperature For operation °C - 25…+ 70 For storage °C - 40…+ 70 Vibration resistance 15 gn (10…500 Hz) conforming to IEC 60068-2-6 Shock resistance 70 gn conforming to IEC 60068-2-27 Electric shock protection Class II conforming to IEC 61140 Degree of protection IP 65 conforming to IEC 60529 IK 08 conforming to EN 50102 Mechanical durability (in millions of operating cycles) 3 Enclosure Double insulated polypropylene, coloured yellow throughout Cable entry Rubber sleeve with stepped entry diameter for cable Ø 7…Ø 18 mm Contact block characteristics Rated operational characteristics A A a AC-15: A600 or Ue = 600 V, le = 1.2 A or Ue = 240 V, Ie = 3 A c DC-13: Q600 or Ue = 600 V, le = 0.1 A or Ue = 250 V, Ie = 0.27 A conforming to EN/IEC 947-5-1 Appendix A 10 16 Rated insulation voltage (Ui) V 600, degree of pollution 3, conforming to IEC 60947-1 Rated impulse withstand voltage (U imp) kV 6, conforming to IEC 60947-1 MΩ Mushroom head pushbutton on XAC D22Apppp: N/C contact with positive opening operation conforming to EN/IEC 60947-5-1 Appendix K Single-speed contact blocks: slow break 2-speed contact blocks: snap action y 25 N 16 Thermal current (lthe) 5 XAC D2pA010p XAC D2pA12p1 Positive operation 6 Contact operation Resistance across terminals Operating force 7 XAC D2pA010p, XAC D2pA12p1 Terminal referencing By numbers conforming to CENELEC EN 50013 Short-circuit protection 10 A cartridge fuse type gG (gl) Connection mm2 Captive screw clamp terminals Clamping capacity: 1 x 2.5 or 2 x 1.5 with or without cable end Conforming to IEC 60947-5-1 Appendix C. Utilisation categories AC-15 and DC-13. Operating rate: 3600 operating cycles/hour. Load factor: 0.5. Operational power a.c.supply a 50/60 Hz o Inductive circuit Millions of operating cycles 8 9 d.c. supply c Power broken in W for 1 million operating cycles 1 Ithe Voltage V W o 0,6 230 V 127 V 0,4 24...48 V 0,2 0,1 1 2 10 References: page 6/9 6/8 Dimensions: page 6/14 Application schemes: page 6/15 4 6 10 Current in A Presentation: page 6/16 24 65 48 48 120 40 References 6 Pendant control stations 6 Double insulated with intuitive operation, type XAC D For control circuits Complete stations “ready for use” For control of single-speed hoist motors 13 XAC D21A0101 Weight kg 0.340 1 – XAC D21A0105 0.365 2 1 N/C ZB2 BE102 XAC D24A0101 0.395 XAC D24A0105 0.425 11 12 3 4 12 1 N/C ZB2 BE102 11 13 14 14 11 12 DF565501 13 1 1 N/O 2-directional ZB2 BE101 operator + 1 trigger action Emer. stop Ø 30 mm ZA2 BS834 operator (2) 1 N/C + 1 N/O ZB2 BE102 + ZB2 BE101 11 1 N/C + 1 N/O ZB2 BE102 + ZB2 BE101 12 Reversing, mechanically interlocked XAC D21A0101 Reference For Emergency stop – 14 Contact block(s) and scheme Per direction 1 N/O ZB2 BE101 13 Number of operators 1 2-directional operator 14 DF565503 Functions For control of 2-speed hoist motors 43 24 44 23 33 14 13 Reference 34 Reversing, mechanically interlocked Contact block(s) and scheme Per direction 1 N/O + N/O staggered S1 XED S1231 (1) For Emergency stop – XAC D21A1231 Weight kg 0.365 – XAC D21A1241 0.405 51 13 23 43 24 1 N/C + N/O + N/O staggered S1 XED S1241 (1) 11 1 N/C ZB2 BE102 XAC D24A1231 0.420 12 23 43 24 62 S1 8 11 23 43 24 44 1 N/C ZB2 BE102 XAC D24A1241 0.420 12 13 33 14 44 51 61 52 62 34 S2 1 N/C + N/O + N/O staggered S1 XED S1241 (1) 6 7 44 13 33 14 1 N/O + N/O staggered XED S1231 (1) 34 DF565502 1 2-directional operator + 1 trigger action latching Emergency stop Ø 30 mm ZA2 BS834 operator (2) 34 S2 XAC D21A1231 5 S2 33 14 DF565504 XAC D24A0105 Number of operators 1 2-directional operator 61 52 Functions 9 S2 XAC D24A1241 (1) Reference of double contact block for reversing operation. (2) Trigger action mechanically latching Emergency stop pushbuttons conform to standards EN/IEC 60204-32, EN/ISO 13850: 2006, Machinery directive 98/37/EC and standard EN/IEC 60947-5-5. Characteristics: page 6/8 Dimensions: page 6/14 Application schemes: page 6/15 Presentation: page 6/16 6/9 10 Characteristics 6 Pendant control stations Double insulated with intuitive operation, type XAC D For power circuits (direct switching) Environment 1 2 3 4 Conformity to standards Protective treatment Standard version Ambient air temperature For operation °C - 25…+ 70 For storage °C - 40…+ 70 “TH” Vibration resistance 15 gn (10…500 Hz) conforming to IEC 60068-2-6 Shock resistance 100 gn conforming to IEC 60068-2-27 except XAC D 2-speed: 70 gn Electric shock protection Class II conforming to IEC 61140 Degree of protection IP 65 conforming to IEC 60529 IK 08 conforming to EN 50102 Mechanical durability (in millions of operating cycles) 3 Enclosure Double insulated polypropylene, coloured yellow throughout Cable entry Rubber sleeve with stepped entry diameter for cable Ø 7…Ø 18 mm Contact block characteristics Thermal current (lthe) 5 EN/IEC 60947-5-1 EN/IEC 60204-32, UL 508, CSA C22-2 n° 14 EN/IEC 60947-5-5 and EN/ISO 13850: 2006 for versions with trigger action Emergency stop EN/IEC 60947-3 XEN Tpppp A 10 XED Spppp A 16 Rated insulation voltage (Ui) V 500, degree of pollution 3 conforming to IEC 60947-1 400, degree of pollution 3 for Emergency stop contact on stations XAC D22Ppppp Rated impulse withstand voltage (U imp) kV 6, conforming to IEC 60947-1 4 for Emergency stop contact on stations XAC D22Ppppp Contact operation Snap action N Operating force 6 Single-speed: 28; 2-speed: 31 Terminal referencing By numbers conforming to CENELEC EN 50005 Short-circuit protection 6 A maximum cartridge fuse type aM Connection mm2 Operational power Screw clamp terminals Clamping capacity: 1 x 2.5 or 2 x 1.5 with or without cable end Utilisation categories AC-3 and AC-4 conforming to IEC 60947-3 Appendix A 3 phases, 2 poles XED S2ppp: 1.1 kW-400 V XED S3ppp: 2.2 kW-400 V Brake contact: 100 V d.c. supply, 0.7 A, L/R = 100 ms Utilisation category AC-23B, mushroom head Emergency stop 3 phases, 3 poles, isolating block: XEN Tpppp: 3 kW-400 V Utilisation categories AC-3 and AC-4 conforming to IEC 60947-3 Appendix A Duty cycle comprising 75% AC-3, 25% AC-4 Operating rate: 600 per hour, load factor: 0.4 3 phases, 2 poles XED S2ppp: 1.1 kW-400 V = 1 million XED S3ppp: 2.2 kW-400 V = 1 million 7 Electrical durability (in millions of operating cycles) 8 9 10 References: page 6/11 6/10 Dimensions: page 6/14 Application schemes: page 6/15 Presentation: page 6/16 6 References 6 Pendant control stations 6 Double insulated with intuitive operation, type XAC D For power circuits (direct switching) Complete stations “ready for use” For control of single-speed hoist motors Functions Number of operators Contact blocks Per direction Maximum operational power/400 V Reference For Emergency stop – 1.1 kW XAC D21P2111 kg 0.355 2-pole XED S3111 (1) – 2.2 kW XAC D21P3111 0.355 2-pole + 1 N/O (brake) XED S2121 (1) – 1.1 kW XAC D21P2121 0.355 2-pole + 1 N/O (brake) XED S3121 (1) – 2.2 kW XAC D21P3121 0.355 2-pole XED S3111 (1) 1 N/C + N/C + N/C XEN T1991 2.2 kW XAC D24P3111 (2) 0.410 2-pole + 1 N/O (brake) XED S2121 (1) 1 N/C + N/C + N/C XEN T1991 1.1 kW XAC D24P2121 (2) 0.410 2-pole + 1 N/O (brake) XED S3121 (1) 1 N/C + N/C + N/C XEN T1991 2.2 kW XAC D24P3121 (2) 0.410 Reference For Emergency stop – Maximum operational power/400 V 1.1 kW XAC D21P2231 kg 0.355 2-pole XED S3231 (1) – 2.2 kW XAC D21P3231 0.355 2-pole + 1 N/O (brake) XED S2241 (1) – 1.1 kW XAC D21P2241 0.355 2-pole + 1 N/O (brake) XED S3241 (1) – 2.2 kW XAC D21P3241 0.355 2-pole XED S2231 (1) 1 N/C + N/C + N/C XEN T1991 1.1 kW XAC D24P2231 (2) 0.420 2-pole XED S3231 (1) 1 N/C + N/C + N/C XEN T1991 2.2 kW XAC D24P3231 (2) 0.420 2-pole + 1 N/O (brake) XED S3241 (1) 1 N/C + N/C + N/C XEN T1991 2.2 kW XAC D24P3241 (2) 0.420 DF565500 2-pole 1 2-directional XED S2111 (1) operator Reversing, mechanically interlocked DF565501 XAC D21P2111 1 2-directional operator + 1 trigger action latching Emergency stop Ø 30 mm operator ZA2 BS834 (2) XAC D24P2121 Functions Number of operators Contact blocks Per direction DF565504 Reversing, mechanically interlocked DF565502 XAC D21P2231 1 2-directional operator + 1 trigger action latching Emergency stop Ø 30 mm operator ZA2 BS834 (2) 1 2 3 4 5 For control of 2-speed hoist motors 1 2-pole 2-directional XED S2231 (1) operator XAC D24P3241 Weight Weight 6 7 8 9 (1) Reference of double contact block for reversing operation. (2) Trigger action mechanically latching Emergency stop pushbuttons conform to standards EN/IEC 60204-32, EN/ISO 13850: 2006, Machinery directive 98/37/EC and standard EN/IEC 60947-5-5. 10 Characteristics: page 6/10 Dimensions: page 6/14 Application schemes: page 6/15 Presentation: page 6/16 6/11 References 6 Pendant control stations 6 Double insulated with intuitive operation, type XAC D For control or power circuits Empty enclosures, separate components and spare parts Empty enclosures Description Empty enclosure comprising: - the enclosure, - protective cable sleeve for Ø 7 to 18 mm cable, - internal cable clamp, - cable tie (for tightening sleeve onto cable), - the directional operator, - legends. DF565505 1 2 Enclosure cut-outs Reference For directional operator XAC D021 Weight kg 0.345 For directional operator + operating head (Ø 22.5 mm cut-out) XAC D022 0.345 Variable composition stations, factory assembled Use the order form on page 6/17 to define the required configuration. 3 DF565506 XAC D021 Equipment: contact blocks and operating heads See separate components, pages 6/13 and 6/14 Contact blocks Description Application Function (1) Scheme (1) Max. power/ 400 V Reference Weight kg – ZB2 BE101 0.015 – ZB2 BE102 0.015 – XED S1231 0.015 – XED S1241 0.015 (2) 1.1 kW 2.2 kW XED S2111 XED S3111 0.080 0.090 2-pole + 1 N/O (brake) (2) 1.1 kW 2.2 kW XED S2121 XED S3121 0.090 0.090 2-pole (2) 1.1 kW 2.2 kW XED S2231 XED S3231 0.110 0.110 2-pole + 1 N/O (brake) (2) 1.1 kW 2.2 kW XED S2241 XED S3241 0.120 0.120 – ZB2 BE102 0.015 – XEN T1991 0.040 For control circuits Single-speed N/O ●4 ●3 4 Single block spring return, slow break 43 24 44 13 23 33 14 43 24 34 44 DF565505 S2 For power circuits Double block spring return, snap action Single-speed 2-pole DF565509 XED S1231 2-speed XED S2121 21 31 32 10 11 XEN T1991 22 N/C + N/C + N/C 12 12 N/C 11 For Emergency stop operating head (Ø 22.5 mm cut-out) Single block spring return, slow break DF565510 9 S1 61 52 N/C + N/O + N/O staggered ZB2 BE10p 51 S2 7 8 S1 62 6 23 ●2 N/O + N/O staggered 13 2-speed 33 14 Double block spring return, snap action 34 XAC D022 DF565505 5 ●1 N/C (1) Function or scheme per direction for double contact blocks. (2) See application schemes, page 6/15. Characteristics: pages 6/8 and 6/10 6/12 Dimensions: page 6/14 Application schemes: page 6/15 Presentation: page 6/16 References 6 Pendant control stations 6 Double insulated with intuitive operation, type XAC D For control or power circuits Separate components and spare parts 817505 Contact block support plates For use with Reference 2 movement contact blocks ZB2 BE10p (control circuit stations) XAC D913 Weight kg 0.010 1 contact block ZB2 BE102 for operating head XAC D911 0.005 1 contact block XEN T1991 for operating head XAC D912 0.010 Colour Reference 1 trigger action latching Emergency stop Ø 30 mm operator (1) Turn to release Red ZA2 BS834 Weight kg 0.040 1 trigger action latching Emergency stop Ø 30 mm operator Key release, n° 455 (2) Key withdrawal in rest (unactuated) position Red ZA2 BS934 0.060 Selector switch, standard handle 2 position, stay put Black ZA2 BD2 0.018 Key switch (key n° 455) (2) 2 position, stay put Key withdrawal in left-hand position – ZA2 BG2 0.020 Key switch (key n° 455) (2) 2 position, spring return from right to left Key withdrawal in left-hand position – ZA2 BG6 0.020 Key switch (key n° 455) (2) 2 position, stay put Key withdrawal in left and right-hand position – ZA2 BG4 0.020 Key switch (key n° 455) (2) (3) 3 position, stay put Key withdrawal in left and right-hand position – ZA2 BG5 0.020 Key switch (key n° 455) (2) (3) 3 position, stay put Key withdrawal in centre position – ZA2 BG3 0.020 1 817503 XAC D913 2 817504 XAC D911 Operating heads for Ø 22.5 mm cut-out Description 817495 XAC D912 DF538494 ZA2 BS834 4 DF565513 DF565514 5 6 ZA2 BS934 ZA2 BD2 3 7 8 ZA2 BG2 (1) Trigger action mechanically latching Emergency stop pushbuttons conform to standards EN/IEC 60204-32, EN/ISO 13850: 2006, Machinery directive 98/37/EC and standard EN/IEC 60947-5-5. (2) Other key numbers available on request, please consult your Regional Sales Office. (3) Only suitable for front mounting. 9 10 Characteristics: pages 6/8 and 6/10 Dimensions: page 6/14 Application schemes: page 6/15 Presentation: page 6/16 6/13 Pendant control stations References, dimensions 6 6 Double insulated with intuitive operation, type XAC D For control or power circuits Complementary accessories .817500 1 .817501 Complementary accessories XAC D901 – XAC D901 0.030 Diaphragm for directional operator, polychloroprene Black XAC D902 0.015 Tightening tool for fixing nut – ZA2 BZ905 0.060 Directional operator with set of legends (single-speed and 2-speed) – XAC D905 0.005 Blanking plug for Ø 22.5 mm cut-out, with seal and fixing nut Black ZB2 SZ3 0.010 Pendant station circuit type Sold in lots of Unit reference Control 50 XAC D950 0.001 Power, 1.1 kW 50 XAC D951 0.001 Power, 2.2 kW 50 XAC D952 0.001 XAC D902 530306 2 Protective cable sleeve for cable Ø 7 to 18 mm 3 .565259 ZA2 BZ905 4 Printed labels, pendant station characteristics Description 5 6 817506 XAC D905 Self-adhesive labels product identification ZB2 SZ3 Dimensions XAC Dppp internal Ø 7......9 10…12 13…15 16…18 7 Ø8 240 300,5 8 9 91 82 118 (1) 10 (1) With trigger action latching Ø 30 mm Emergency stop ZA2 BS834. 6/14 Weight kg Pendant control stations Application schemes (typical examples) 6 6 Double insulated with intuitive operation, type XAC D For control or power circuits Control circuits XAC D21A0105 1 11 A1 A1 12 14 21 A2 A2 22 A2 2 – KM2 23 13 23 51 XAC D21A1241 13 XAC D21A1231 3 A1 A1 A2 – KM2 A2 43 44 14 33 34 A1 61 – KM A2 A2 A2 – S2 – KM1 – KM1 62 A1 A1 52 24 43 44 14 33 A1 34 – KM A2 – KM2 24 – S1 – S1 – S2 – KM1 – S2 – KM1 A2 – KM2 23 14 A1 – S1 – S2 24 23 A1 24 – S1 13 13 XAC D21A0101 4 Power circuits For control of single-speed reversing motor 2-phase switching (1) 3 13 L3 L1 L2 1 L2 1 L1 XAC D21P2121, XAC D21P3121 L3 5 3 XAC D21P2111, XAC D21P3111 7 8 4 5 – S2 6 15 4 7 14 2 5 2 – S1 – S1 6 W V U W V U 16 8 6 – S2 (1) Brake supply. 7 For control of 2-speed reversing motor (motors with separate windings only) 2-phase switching XAC D21P2231, XAC D21P3231 (1) 8 9 R1 3 2 4 R2 10 7 R3 11 15 5 9 12 R4 16 8 10 11 12 R4 L3 – S2 6 R2 R3 1 13 4 7 – S2 8 L2 – S1 14 2 5 – S1 6 L1 9 L3 R1 L2 3 1 L1 XAC D21P2241, XAC D21P3241 Y U1 U2 U1 U2 V1 V2 V1 V2 W1 W2 W1 W2 10 (1) Brake supply. Characteristics: pages 6/8 and 6/10 References: pages 6/9 to 6/13 Dimensions: page 6/14 Presentation: page 6/16 6/15 Presentation 6 Pendant control stations Double insulated with intuitive operation, type XAC D For control or power circuits Variable composition stations, factory assembled 1 2 3 4 5 6 7 8 9 10 6/16 6 Pendant control stations Order form (specimen suitable for photocopying) 6 Double insulated with intuitive operation, type XAC D 6 For control or power circuits Variable composition stations, factory assembled Customer Company Order N° Delivery date Enter the order with XAC D09 reference Unit reference of empty enclosure, see page 6/12 XAC D 0 Schneider Electric Industries Sales office - Subsidiary Co. Order N° Number of identical stations Enclosure price (1) 1 2 2 The reference of the empty enclosure above comprises: - the enclosure, - internal cable clamp, - cable tie (for tightening sleeve onto cable), - the directional operator with set of legends, XAC D905, - protective cable sleeve for Ø 7 to 18 mm cable, XAC D901, - diaphragm for directional operator, XAC D902. Operating head see page 6/13 Reference Contact blocks see page 6/12 Unit price Reference Contact blocks see page 6/12 Reference 3 Support plate see page 6/13 Unit price Reference Unit price 4 Total price Support plate (for ZB2 BEppp only) see page 6/13 Qty. Unit price Reference Qty. Unit price 5 Total price 6 Factory assembly: Add an additional cost for assembly XAC 9VA Total price of assembled pendant station 7 (1) Obtain the empty enclosure price. 8 9 10 6/17 Characteristics 6 Pendant control stations 6 Double insulated, type XAC A For control circuits Environment 1 2 3 4 Conformity to standards EN/IEC 60947-5-1 EN/IEC 60204-32, UL 508, CSA C22-2 n° 14 EN/IEC 60947-5-5 and EN/ISO 13850: 2006 for versions with trigger action Emergency stop Product certifications Special version, with suffix “H7”: UL Listed A600-Q600, CSA A600-Q600, CCC, GOST Protective treatment Standard version “TH” Ambient air temperature For operation °C - 25…+ 70 For storage °C - 40…+ 70 Vibration resistance 15 gn (10…500 Hz) conforming to IEC 60068-2-6 Shock resistance 100 gn conforming to IEC 60068-2-27 Electric shock protection Class II conforming to IEC 61140 Degree of protection IP 65 conforming to IEC 60529 IK 08 conforming to EN 50102 Mechanical durability (in millions of operating cycles) 1 Enclosure Double insulated polypropylene, coloured yellow throughout Cable entry Rubber sleeve with stepped entry diameter for cable Ø 8…Ø 26 mm Contact block characteristics Rated operational characteristics ZB2 BEppp, XEN Gpppp, XAC Spppp a AC-15: A600 or Ue = 600 V, le = 1.2 A or Ue = 240 V, Ie = 3 A c DC-13: Q600 or Ue = 600 V, le = 0.1 A or Ue = 250 V, Ie = 0.27 A XEN Tpppp 5 Thermal current (lthe) Rated insulation voltage (Ui) A 10 ZB2 BEppp, XEN Gpppp, XAC Spppp V 600, degree of pollution 3 XEN Tpppp V 400, degree of pollution 3, conforming to EN/IEC 60947-1 kV 6, conforming to EN/IEC 60947-1 Rated impulse withstand voltage (U imp) 6 a AC-15: A300 or Ue = 240 V, le = 3 A c DC-13: Q300 or Ue = 250 V, le = 0.27 A conforming to EN/IEC 60947-5-1 Appendix A Positive operation Mushroom head pushbutton: N/C contact with positive opening operation conforming to EN/IEC 60947-5-1 Appendix K Contact operation N/C or N/O slow break Resistance across terminals MΩ y 25 Operating force N Operators - with 1 N/O contact: 10 - with 1 N/C contact: 8 - with additional N/O contact: + 5 - with additional N/C contact: + 3 7 Terminal referencing Conforming to CENELEC EN 50013 Short-circuit protection 10 A cartridge fuse type gG (gl) Screw and captive cable clamp terminals. Clamping capacity: min. 1 x 0.5 mm2, max., with or without cable end: 2 x 1.5 mm2 or 1 x 2.5 mm2. 6.3 mm clips (on request), please consult your Regional Sales office. Conforming to EN/IEC 60947-5-1 Appendix C. Utilisation categories AC-15 and DC-13. Operating rate: 3600 operating cycles/hour. Load factor: 0.5. Connection 8 mm2 Operational power d.c. supply c Power broken in W for 1 million operating cycles Millions of operating cycles a.c.supply a 50/60 Hz o Inductive circuit 9 10 1 Ithe Voltage V W o 0,6 230 V 127 V 0,4 24...48 V 0,2 0,1 1 References: pages 6/19 to 6/22 6/18 Dimensions: page 6/30 2 Application schemes: page 6/31 4 6 10 Current in A Presentation: page 6/32 24 65 48 48 120 40 References 6 Pendant control stations 6 Double insulated, type XAC A For control circuits Complete stations “ready for use” For control of single-speed motors 1 – XAC A281 0.500 2 1 N/C ZB2 BE102 XAC A2714 (1) 0.575 11 13 13 14 14 13 XAC A271 Weight kg 0.475 11 1 N/C ZB2 BE102 XAC A2814 (1) 0.600 4 31 12 21 32 31 22 21 32 11 12 22 1 N/C + N/C + N/C XEN T1192 11 1 N/C + N/C + N/C XEN T1192 12 13 14 3 12 14 13 11 1 N/C + 1 N/O ZB2 BE102 + ZB2 BE101 12 14 DF565524 1 N/O ZB2 BE101 13 2 1 N/O mechanically ZB2 BE101 interlocked + 1 trigger action latching Emergency stop Ø 30 mm operator 1 N/C + 1 N/O ZA2 BS834 (1) ZB2 BE102 + ZB2 BE101 XAC A2714 XAC A2814 Reference 14 DF565524 XAC A271 XAC A281 11 1 N/C + 1 N/O ZB2 BE102 + ZB2 BE101 12 2 mechanically interlocked Contact block(s) and scheme Per direction For Emergency stop 1 N/O – ZB2 BE101 11 Number of operators 12 DF565523 Functions XAC A27141 (1) 0.615 5 XAC A28141 (1) 0.635 6 XAC A27141 XAC A28141 (1) Trigger action mechanically latching Emergency stop pushbuttons conform to standards EN/IEC 60204-32, EN/ISO 13850: 2006, Machinery directive 98/37/EC and standard EN/IEC 60947-5-5. 7 8 9 10 Characteristics: page 6/18 Dimensions: page 6/30 Application schemes: page 6/31 Presentation: page 6/32 6/19 References (continued) 6 Pendant control stations 6 Double insulated, type XAC A For control circuits Complete stations “ready for use” 1 N/C ZB2 BE102 XAC A4714 (1) 0.800 XAC A4814 (1) 0.815 XAC A47141 (1) 0.835 XAC A48141 (1) 0.850 – XAC A671 0.860 – XAC A681 0.950 1 N/C ZB2 BE102 XAC A6714 (1) 0.845 XAC A6814 (1) 0.935 11 12 11 12 31 32 31 21 22 32 11 12 21 1 N/C + N/C + N/C XEN T1192 11 13 14 11 13 12 14 1 N/C + N/C + N/C XEN T1192 14 13 6 1 N/O mechanically ZB2 BE101 interlocked between pairs 1 N/C ZB2 BE102 XAC A671 XAC A681 11 12 12 1 N/C ZB2 BE102 11 11 13 12 13 14 1 N/C + 1 N/O ZB2 BE102 + ZB2 BE101 11 8 1 N/O ZB2 BE101 13 6 mechanically interlocked between pairs + 1 trigger action latching Emergency stop Ø 40 mm operator ZA2 BS844 (1) 12 7 14 530223 1 N/C + 1 N/O ZB2 BE102 + ZB2 BE101 14 530224 6 0.675 13 1 N/C + 1 N/O ZB2 BE102 + ZB2 BE101 1 N/C + 1 N/O ZB2 BE102 + ZB2 BE101 XAC A4714 XAC A4814 XAC A47141 XAC A48141 XAC A481 14 11 13 12 13 1 N/O ZB2 BE101 1 N/O ZB2 BE101 5 – 22 4 XAC A471 Weight kg 0.625 12 530226 XAC A471 XAC A481 Reference 14 3 4 mechanically interlocked between pairs + 1 trigger action latching Emergency stop Ø 40 mm operator ZA2 BS844 (1) 14 1 N/C + 1 N/O ZB2 BE102 + ZB2 BE101 2 11 4 mechanically interlocked between pairs Contact block(s) and scheme Per direction For Emergency stop 1 N/O – ZB2 BE101 13 Number of operators 12 Functions 14 DF565525 1 For control of single-speed motors (continued) XAC A6714 XAC A6814 (1) Trigger action mechanically latching Emergency stop pushbuttons conform to standards EN/IEC 60204-32, EN/ISO 13850: 2006, Machinery directive 98/37/EC and standard EN/IEC 60947-5-5. 9 10 Characteristics: page 6/18 6/20 Dimensions: page 6/30 Application schemes: page 6/31 Presentation: page 6/32 References (continued) 6 Pendant control stations 6 Double insulated, type XAC A For control circuits Complete stations “ready for use” For control of single-speed motors (continued) XAC A871 XAC A881 31 32 31 32 21 22 21 22 11 12 11 XAC A68141 (1) 0.970 2 XAC A871 0.940 3 14 13 12 13 13 14 14 11 12 1 11 1 N/C + 1 N/O ZB2 BE102 + ZB2 BE101 13 XAC A67141 XAC A68141 – XAC A67141 (1) Weight kg 0.880 – XAC A881 1.045 4 14 O 1 N/O on 7 operators ZB2 BE101 and 1 N/C on the 8th operator ZB2 BE102 1 N/C + N/C + N/C XEN T1192 Reference 12 I 1 N/C + 1 N/O ZB2 BE102 + ZB2 BE101 11 8 mechanically interlocked between pairs Contact block(s) and scheme Per direction For Emergency stop 1 N/O 1 N/C + N/C ZB2 BE101 + N/C XEN T1192 12 Number of operators 6 mechanically interlocked between pairs + 1 trigger action latching Emergency stop Ø 40 mm operator ZA2 BS844 (1) DF565527 DF565526 Functions For control of 2-speed motors 21 13 33 22 14 34 XAC A291 Weight kg 0.525 5 0.570 12 11 6 21 31 32 XAC A29141 (1) 22 1 N/C + N/C + N/C XEN T1192 11 33 34 33 34 XAC A2914 (1) 12 13 14 13 14 1 N/C + N/O + N/O staggered XEN G1191 Reference 1 N/C ZB2 BE102 21 XAC A2914 XAC A29141 1 N/C + N/O + N/O staggered XEN G1191 22 2 mechanically interlocked between pairs + 1 trigger action latching Emergency stop Ø 30 mm operator ZA2 BS834 (1) Contact block(s) and scheme Per direction For Emergency stop 1 N/C + N/O + N/O – staggered XEN G1191 21 2 mechanically interlocked between pairs 530230 530229 XAC A291 Number of operators 22 Functions 0.605 7 (1) Trigger action mechanically latching Emergency stop pushbuttons conform to standards EN/IEC 60204-32, EN/ISO 13850: 2006, Machinery directive 98/37/EC and standard EN/IEC 60947-5-5. 8 9 10 Characteristics: page 6/18 Dimensions: page 6/30 Application schemes: page 6/31 Presentation: page 6/32 6/21 References (continued) 6 Pendant control stations 6 Double insulated, type XAC A For control circuits Complete stations “ready for use” 0.675 1 N/C ZB2 BE102 XAC A4924 (1) 0.700 XAC A49241 (1) 0.735 (b) XAC A4914 XAC A49141 11 21 31 22 32 12 11 12 33 34 33 1 N/C + N/C + N/C XEN T1192 13 14 11 33 12 11 21 31 12 22 32 34 21 13 14 1 N/O (b) ZB2 BE101 1 N/C + N/C + N/C XEN T1192 13 8 22 1 N/C + N/O + N/O staggered (a) XEN G1191 14 537743 XAC A492 33 14 13 1 N/O (b) ZB2 BE101 34 21 13 1 N/C + N/O + N/O staggered (a) XEN G1191 22 4 mechanically interlocked between pairs + 1 trigger action latching Emergency stop Ø 40 mm operator ZA2 BS844 (1) 6 7 33 34 21 13 22 14 21 13 22 14 1 N/O (b) ZB2 BE101 1 N/C ZB2 BE102 DF565528 5 33 XAC A492 1 N/C + N/O + N/O staggered (a) XEN G1191 34 – 4 mechanically interlocked between pairs 21 0.700 13 XAC A49141 (1) 1 N/C + N/O + N/O staggered XEN G1191 22 0.675 14 XAC A4914 (1) 1 N/C + N/O + N/O staggered XEN G1191 XAC A491 9 Weight kg 0.625 34 4 4 mechanically interlocked between pairs + 1 trigger action latching Emergency stop Ø 40 mm operator ZA2 BS844 (1) 21 (a) Reference 14 3 530231 XAC A491 Contact block(s) and scheme Per direction For Emergency stop 4 1 N/C + N/O – mechanically + N/O interlocked staggered between pairs XEN G1191 13 2 Number of operators 22 Functions 14 DF565528 1 For control of 2-speed motors (continued) XAC A4924 XAC A49241 (1) Trigger action mechanically latching Emergency stop pushbuttons conform to standards EN/IEC 60204-32, EN/ISO 13850: 2006, Machinery directive 98/37/EC and standard EN/IEC 60947-5-5. 10 Characteristics: page 6/18 6/22 Dimensions: page 6/30 Application schemes: page 6/31 Presentation: page 6/32 References 6 Pendant control stations 6 Double insulated, type XAC A For control circuits Empty enclosures Empty enclosures 530233 Description Enclosure comprising: - the enclosure, - internal mounting plate, - protective cable sleeve, - internal cable clamp, - suspension ring, - cable tie (for tightening sleeve onto cable). Number of cut-outs 2 Reference Weight kg 0.440 1 3 XAC A03 (1) 0.440 2 4 XAC A04 0.540 XAC A02 530234 XAC A02 3 530234 XAC A03 5 XAC A05 (1) 0.625 6 XAC A06 0.665 8 XAC A08 0.770 12 XAC A12 1.000 4 5 6 Variable composition stations, factory assembled Use the order form on page 6/33 to define the required configuration. Equipment: contact blocks, operating heads (control and signalling), complementary accessories See separate components, pages 6/24 to 6/29 7 (1) Enclosures with 3 cut-outs XAC A03 and 5 cut-outs XAC A05 cannot be fitted with a mounting adaptor for base mounted units. The first cut-out can only be used for the Emergency stop function. XAC A12 8 9 10 Characteristics: page 6/18 Dimensions: page 6/30 Application schemes: page 6/31 Presentation: page 6/32 6/23 References 6 Pendant control stations 6 Double insulated, type XAC A For control circuits Separate components and spare parts Contact blocks for front mounting Function Single-speed N/O Scheme Reference ZB2 BE101 Weight kg 0.015 ZB2 BE102 0.015 XEN G1491 0.040 XEN G1191 0.040 XEN G3781 0.060 XEN G3791 0.060 4 Single block, spring return slow break Application 3 Description 530238 1 ZB2 BE101 ZB2 BE102 1 N/C 21 13 33 22 14 34 Single-speed N/O 13 14 530236 Double block, latching slow break (2) 13 4 33 XEN G1191 XEN G1491 34 N/C + N/O + N/O staggered (1) 21 2-speed 13 3 22 N/C + N/O + N/O simultaneous (1) 14 530237 2 2 N/O 13 14 5 12 Isolating switch, slow break, for front mounting 31 32 Emergency stop N/C + N/C + N/C with positive opening operation Reference 21 Scheme 11 Function 22 Application 12 For mounting in enclosures XAC A03 (frontal cut-out) XAC A05, A06, A08 (frontal or base cut-out) 530239 7 N/C XEN G3781 XEN G3791 6 11 14 N/O XEN T1192 XEN T1192 (1) Only for use with XAC A9ppp operators. (2) Not suitable for use with the following operating heads: ZA2 BB, ZA2 BD, ZA2 BG and ZA2 BS. . 8 9 10 Characteristics: page 6/18 6/24 Dimensions: page 6/30 Application schemes: page 6/31 Presentation: page 6/32 Weight kg 0.050 References (continued) 6 Pendant control stations 6 Double insulated, type XAC A For control circuits Separate components and spare parts Contact blocks for base mounting N/O Scheme Reference XAC S101 Weight kg 0.030 1 XAC S102 0.030 2 XAC S103 0.045 N/C 23 3 24 11 21 12 11 23 12 N/C + N/O 24 N/C + N/C 22 14 N/O + N/O 13 12 XAC S10p 11 14 Spring return slow break (1) Function 13 530240 Description XAC S104 0.045 XAC S105 0.045 Reference ZB2 BV006 Weight kg 0.015 ZB2 BV007 0.020 530241 Pilot light bodies for front mounting Description Direct supply Bulb not included (2) Supply voltage y 400 V Scheme X1 4 5 ZB2 BV006 X2 530242 Direct supply, through resistor Incandescent BA 9s base fitting 130 V bulb included ZB2 BV007 230 V X1 6 X2 (1) Not suitable for use with 3-position operating heads ZA2 BD and ZA2 BG or for mounting in enclosures XAC A039 and XAC A03. (2) Bulb type for use with direct supply units: BA 9s base fitting incandescent bulb U y 130 V or neon bulb 110 V y U y 400 V. Maximum power: 2.6 W, maximum Ø: 11 mm, maximum length: 28 mm. See page 6/26. 7 8 9 10 6/25 References (continued) 6 Pendant control stations 6 Double insulated, type XAC A For control circuits Separate components and spare parts 530243 Operating heads for front mounting 1 Description XAC A94pp Booted operators 2 3 Unit reference White Sold in lots of 10 XAC A9411 Weight kg 0.010 Black 10 XAC A9412 0.010 Green 10 XAC A9413 0.010 Red 10 XAC A9414 0.010 Yellow 10 XAC A9415 0.010 Blue 10 XAC A9416 0.010 Brown 10 XAC A9419 0.010 Operating heads for front or base mounting 530249 Description 4 DF538493 ZA2 BS834 5 Colour Colour Type Reference Weight kg Trigger action latching Emergency stop (1) Turn to release Red Ø 30 mm ZA2 BS834 0.040 Ø 40 mm ZA2 BS844 0.050 Trigger action latching Emergency stop (2) Key release (n° 455) Key withdrawal in rest (unactuated) position Red Ø 30 mm ZA2 BS934 0.060 Ø 40 mm ZA2 BS944 0.065 Selector switches (3), standard handle (Not to be used with XEN Gpppp contact blocks) Black 2 position, stay put ZA2 BD2 0.018 3 position, stay put (4) ZA2 BD3 0.018 Key switches (2) (key n° 455) Key withdrawal in left and right-hand position – 2 position, stay put ZA2 BG4 0.042 3 position, stay put (4) ZA2 BG5 0.042 Key switch (2) (key n° 455) Key withdrawal in left-hand position – 2 position, stay put ZA2 BG2 0.042 Key switch (2) (key n° 455) Spring return from right to left Key withdrawal in left-hand position – 2-position ZA2 BG6 0.042 Key switch (4) (2) (key n° 455) Key withdrawal in centre position – 3 position, stay put ZA2 BG3 0.042 Wobblesticks (5) Operates in all directions for fast stop Black – ZA2 BB2 0.060 Red – ZA2 BB4 0.060 6 530245 ZA2 BS944 7 530246 ZA2 BDp 8 DF565529 ZA2 BGp ZA2 BBp (1) Trigger action mechanically latching Emergency stop pushbuttons conform to standards EN/IEC 60204-32, EN/ISO 13850: 2006, Machinery directive 98/37/EC and standard EN/IEC 60947-5-5. (2) Other key numbers available on request, please consult your Regional Sales Office. (3) Selector switches available with other mechanical functions, please consult your Regional Sales Office. (4) Only suitable for front mounting. (5) Base mounting recommended. 9 10 Characteristics: page 6/18 6/26 Dimensions: page 6/30 Application schemes: page 6/31 Presentation: page 6/32 References (continued) 6 Pendant control stations 6 Double insulated, type XAC A For control circuits Separate components and spare parts 530250 Pilot light heads Description Colour Reference Weight kg For use with incandescent bulbs Lens cap with bezel and fixing nut 530202 530201 ZA2 BV0p DL1 CFppp DF565531 530203 DL1 Cpppp DF565530 XAC A009 ZB2 SZ3 530206 530205 0.015 Green ZA2 BV03 0.015 Red ZA2 BV04 0.015 Yellow ZA2 BV05 0.015 Blue ZA2 BV06 0.015 Clear ZA2 BV07 0.015 Green ZA2 BV033 0.015 Red ZA2 BV043 0.015 Yellow ZA2 BV053 0.015 Clear ZA2 BV073 0.015 2 3 4 Bulbs Description Incandescent BA 9s base fitting Maximum power: 2.6 W Maximum Ø: 11 mm Maximum length: 28 mm XAC A971 530207 XAC B961 ZA2 BV01 For use with neon bulbs Lens cap with bezel and fixing nut XAC A960 White 1 Neon BA 9s base fitting Maximum power: 2.6 W Maximum Ø: 11 mm Maximum length: 28 mm Voltage Unit reference 6V Sold in lots of 10 DL1 CB006 Weight kg 0.002 12 V 10 DL1 CE012 0.002 24 V 10 DL1 CE024 0.002 48 V 10 DL1 CE048 0.002 130 V 10 DL1 CE130 0.002 110 V 10 DL1 CF110 0.002 230 V 10 DL1 CF220 0.002 400 V 10 DL1 CF380 0.002 Complementary accessories, tools Description 530208 XAC A982 Protective cable sleeve 530200 XAC A983 530306 XBF X13 Reference Weight kg For cable Ø 8 to 22 mm XAC A950 0.070 For cable Ø 8 to 26 mm XAC A960 0.090 Mechanical interlock for 2 operators With fixing screws XAC A009 0.003 Blanking plug With seal and fixing nut ZB2 SZ3 0.005 Tightening tool for fixing nut – ZA2 BZ905 0.060 Adaptor for self-supporting cable type BBAP Mounted with protective sleeve for cable Ø 8 to 26 mm XAC B961 0.025 Lower support ring – XAC A971 0.010 Protective guards for base mounted units For selector switch (standard handle) or Emergency stop head pushbutton XAC A982 0.025 For key switch or key release latching Emergency stop head pushbutton XAC A983 0.045 For BA 9s base fitting bulbs XBF X13 0.025 Bulb extractor ZA2 BZ905 Characteristics: page 6/18 Dimensions: page 6/30 Application schemes: page 6/31 Presentation: page 6/32 6/27 5 6 7 8 9 10 References 6 Pendant control stations 6 Double insulated, type XAC A 530209 For control circuits Legends 30 x 40 mm with symbols conforming to NF E 52-124 1 White background, black symbol 2 3 Reference ZB2 BY4901 Weight kg 0.001 Function Symbol Lower, slow Raise, fast ZB2 BY4902 Raise, slow-fast Reference ZB2 BY2904 Weight kg 0.001 0.001 Lower, fast ZB2 BY2905 0.001 ZB2 BY4903 0.001 Lower, slow-fast ZB2 BY2906 0.001 Right, slow ZB2 BY4907 0.001 Left, slow ZB2 BY2910 0.001 Right, fast ZB2 BY4908 0.001 Left, fast ZB2 BY2911 0.001 Right, slow-fast ZB2 BY4909 0.001 Left, slow-fast ZB2 BY2912 0.001 Forward, slow ZB2 BY4913 0.001 Reverse, slow ZB2 BY2916 0.001 Forward, fast ZB2 BY4914 0.001 Reverse, fast ZB2 BY2917 0.001 Forward, slow-fast ZB2 BY4915 0.001 Reverse, slow-fast ZB2 BY2918 0.001 Slew right, slow ZB2 BY4919 0.001 Slew left, slow ZB2 BY2922 0.001 Slew right, fast ZB2 BY4920 0.001 Slew left, fast ZB2 BY2923 0.001 Slew right, slow-fast ZB2 BY4921 0.001 Slew left, slow-fast ZB2 BY2924 0.001 Slow ZB2 BY4933 0.001 Fast ZB2 BY4934 0.001 Klaxon ZB2 BY4932 0.001 Start-Klaxon ZB2 BY4935 0.001 Start ZB2 BY4930 0.001 Stop ZB2 BY2931 0.001 Black background, white symbol 0 4 Function Symbol Raise, slow Red background, white symbol 5 6 7 8 9 0 10 Characteristics: page 6/18 6/28 Dimensions: page 6/30 Application schemes: page 6/31 Presentation: page 6/32 References Pendant control stations 6 6 Double insulated, type XAC A 530211 For control circuits Legends 30 x 40 mm White Black Text Reference Red Weight kg Text Reference Weight kg 1 b Start functions: white characters on black background b Stop functions: white characters on red background Blank Black or red background 530212 ZB2 BY2101 ZB2 BY2101 0.001 White or yellow background ZB2 BY4101 With English text With French text For pushbuttons For pushbuttons 0.001 2 Start ZB2 BY2303 0.001 Marche ZB2 BY2103 0.001 Stop ZB2 BY2304 0.001 Arrêt ZB2 BY2104 0.001 Forward ZB2 BY2305 0.001 Avant ZB2 BY2105 0.001 Reverse ZB2 BY2306 0.001 Arrière ZB2 BY2106 0.001 Up ZB2 BY2307 0.001 Montée ZB2 BY2107 0.001 Down ZB2 BY2308 0.001 Descente ZB2 BY2108 0.001 Right ZB2 BY2309 0.001 Droite ZB2 BY2109 0.001 Left ZB2 BY2310 0.001 Gauche ZB2 BY2110 0.001 On ZB2 BY2311 0.001 En service ZB2 BY2111 0.001 Off ZB2 BY2312 0.001 Hors service ZB2 BY2112 0.001 Power on ZB2 BY2326 0.001 Sous tension ZB2 BY2126 0.001 Slow ZB2 BY2327 0.001 Lent ZB2 BY2127 0.001 Fast ZB2 BY2328 0.001 Vite ZB2 BY2128 0.001 Klaxon ZB2 BY2125 0.001 Klaxon ZB2 BY2125 0.001 Black White Yellow ZB2 BY4101 For selector switches For selector switches – – 0.001 Arrêt-Marche ZB2 BY2166 – Off-On ZB2 BY2367 0.001 Hors-en ZB2 BY2167 0.001 3 4 5 6 With special texts b Specify text when ordering, b 2 lines maximum, 11 characters per line. White characters on black background White characters on red background Other versions 7 ZB2 BY2002 0.001 ZB2 BY2004 0.001 Black characters on white background Black characters on yellow background ZB2 BY4001 0.001 ZB2 BY4005 0.001 Legends with texts in other languages. Please consult your Regional Sales Office. 8 9 10 Characteristics: page 6/18 Dimensions: page 6/30 Application schemes: page 6/31 Presentation: page 6/32 6/29 Dimensions 6 Pendant control stations Double insulated, type XAC A For control circuits Dimensions 1 XAC A pendant stations for control circuits internal Ø 2 3 4 5 6 7 8 Number of operators 2 3 b 314 314 b1 190 190 c 80 80 (1) For 2 and 3-way XAC A stations. (2) For 4 to 8-way XAC A stations. (3) With trigger action Emergency stop head operator. 4 440 250 80 5 440 250 80 6 500 310 80 8 560 370 80 12 680 490 92 Protective guards XAC A982 57 33 9 XAC A983 80 80 10 Characteristics: page 6/18 6/30 References: pages 6/19 to 6/29 Application schemes: page 6/31 Presentation: page 6/32 6 Application schemes 6 Pendant control stations 6 Double insulated, type XAC A For control circuits Application schemes (typical examples) 33 13 21 14 34 13 33 3 34 22 A1 A1 2 – S1 – S2 14 A1 – KM2 A2 – KM A2 – KM1 A1 A1 A2 A2 – KM1 A2 13 14 – S2 – KM2 1 – S2 – S1 22 11 12 – S1 21 13 14 2 contact blocks XEN G1191 11 For control of 2-speed reversing motor Contact blocks ZB2 BE101 + ZB2 BE102 12 For control of single-speed reversing motor 4 KM: high speed contactor 5 6 7 8 9 10 Characteristics: page 6/18 References: pages 6/19 to 6/29 Dimensions: page 6/30 6/31 Presentation 6 Pendant control stations Double insulated, type XAC A For control circuits Variable composition stations, factory assembled 1 2 3 4 5 6 7 8 9 10 6/32 6 Pendant control stations Order form (specimen suitable for photocopying) 6 6 Double insulated, type XAC A For control circuits Variable composition stations, factory assembled Customer Company Order N° Delivery date Enter the order with XAC A09 reference Unit reference of empty enclosure, see page 6/23 14 XAC Schneider Electric Industries Sales office - Subsidiary Co. Order N° Number of identical stations Enclosure price (1) 1 2 A Legends see pages 6/28 and 6/29 Contact blocks or pilot light bodies see pages 6/24 and 6/25 Reference Reference Unit price Unit price Operating heads or pilot light heads or blanking plug see pages 6/26 and 6/27 Reference Unit price 3 Total price 1 1 2 2 3 4 4 3 5 4 5 6 7 6 8 7 9 8 10 9 10 5 11 6 12 Unit mounted in base of enclosure (if required) (Except when using XAC A03 and XAC A05) 11 13 12 Complementary accessories, see page 6/27 (cross the appropriate box or boxes) Description Reference 13 15 16 17 14 Adaptor for self-supporting cable type BBAP for use with cable entry sleeve Ø 8 to 26 mm 15 Lower support ring XAC B961 16 Protective guard for selector switch (std. handle) or Emergency stop head pushbutton, mounted in base 17 Protective guard for key switch or key release Emergency stop head pushbutton, mounted in base Mechanical interlocking (2) Reference Quantity XAC A982 XAC A009 Factory assembly: 7 Unit price XAC A971 8 XAC A983 Unit price Number of heads or blanking plugs to be fitted Additional cost XAC 9VA for fitting of 1 head or 1 blanking plug 9 X Total price of assembled pendant station (1) Obtain the empty enclosure price. (2) Connect with a line the 2 ways which require mechanical interlocking. Examples: combinations possible Combinations not possible 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 10 6/33 Characteristics 6 Pendant control stations 6 Double insulated, type XAC B Metal, type XAC M For control circuits Environment 1 Conformity to standards EN/IEC 60947-5-1, CSA C22-2 n° 14 Product certifications XAC B XAC M XAC B XAC M For storage For operation Vibration resistance Standard version: CSA 300 V type 4 Standard version: CSA 300 V type 4 Standard version: “TH” Standard version: “TC”, (“TH” on request) - 40…+ 70 - 25…+ 70 15 gn (10…500 Hz) conforming to IEC 60068-2-6 Shock resistance 100 gn conforming to IEC 60068-2-27 Protective treatment Ambient air temperature 2 Electric shock protection 3 Degree of protection Mechanical durability (in millions of operating cycles) Enclosure °C °C XAC B XAC M Class II Class I conforming to IEC 61140 IP 65 conforming to IEC 60529; IK 08 conforming to EN 50102 1 XAC B XAC M Double insulated glass-reinforced polyester (colour: yellow) Aluminium enclosure. Painted yellow Rubber sleeve with stepped entry diameter for cable Ø 7…13 mm, Ø 10…22 mm or Ø 22…35 mm Cable entry 4 Contact block characteristics Rated operational characteristics a AC-15: A300 or Ue = 240 V, le = 3 A c DC-13: Q300 or Ue = 250 V, le = 0.27 A conforming to EN/IEC 60947-5-1 Appendix A Thermal current (lthe) Rated insulation voltage (Ui) 5 XEN Cpppp, XEN D3ppp, XEN D4ppp, XES B2011, XAC S4, XES D1181, XES D1281 XEN Bpppp, XEN D1ppp, XEN D2ppp Rated impulse withstand voltage (U imp) A V 400, degree of pollution 3, conforming to IEC 60947-1 kV Positive operation 6 Resistance across terminals 7 8 9 6, conforming to IEC 60947-1 Mushroom head pushbutton: N/C contact with positive opening operation conforming to EN/IEC 60947-5-1 Appendix K Slow break or snap action Contact operation Operating force 10 500, degree of pollution 3, conforming to IEC 60947-1 With booted operator MΩ y 25 N XAC S4ppp: 10 (N/O), 8 (N/C); XEN Cpppp: 6 (N/O), 4 (N/C); XEN Bpppp, XEN D1ppp, XEN D2ppp: Single-speed: 9; 2-speed: 20 (1st speed), 30 (2nd speed); XEN D3ppp, XEN D4ppp: 25; XES B2011: 7; XES D1181, XES D128: 15 (1st speed), 25 (2nd speed) 10 With spring return mushroom N head operator With latching mushroom head N operator 40 Terminal referencing By numbers conforming to CENELEC EN 50013 Short-circuit protection 10 A cartridge fuse type gG (gl) Connection mm2 Operational power conforming to EN/IEC 60947-5-1 Appendix C Utilisation categories AC-15 and DC-13 For 1 million operating cycles Operating rate: 3600 operating cycles/hour Load factor: 0.5 o Inductive circuit 10 References: page 6/35 6/34 Dimensions: page 6/55 Screw and captive cable clamp terminals. Clamping capacity: 1 x 2.5 or 2 x 1.5 with or without cable end Contact blocks XEN Cpppp, XEN D3ppp, XEN D4ppp, XAC S4ppp a.c. supply a 50/60 Hz d.c. supply c Voltage V 24 48 127 230 Voltage V 24 VA 140 385 525 455 W 60 o o 48 45 120 42 Contact blocks XEN Bpppp, XEN D1ppp, XEN D2ppp a.c. supply a 50/60 Hz d.c. supply c Voltage V 24 48 127 230 Voltage V 24 VA 140 210 640 680 W 48 o o 48 31 120 35 Contact blocks XES B2011, XES D1181, XES D1281 a.c. supply a 50/60 Hz d.c. supply c Voltage V 24 48 127 230 Voltage V 24 VA 50 100 450 750 W 140 o o 48 140 120 95 Application schemes: page 6/56 References 6 Pendant control stations 6 Double insulated, type XAC B For control circuits Complete stations “ready for use” (with snap action contact blocks) For control of single-speed motors DF565565 3 4 2 without mechanical interlocking Contact blocks and scheme Per direction 1 C/O snap action XES B2011 1 Number of operators 2 DF565564 Functions Reference XAC B281 Weight kg 0.850 1 3 4 1 C/O snap action XES B2011 XAC B481 1.100 DF565566 4 without mechanical interlocking 1 XAC B281 2 2 3 1 C/O snap action XES B2011 3 8 without mechanical interlocking 4 1 C/O snap action XES B2011 1 6 without mechanical interlocking XAC B681 1.300 5 3 4 XAC B681 1 I 2 DF565567 XAC B481 2 4 XAC B881 1.550 6 7 O 8 XAC B881 9 10 Characteristics: page 6/34 Dimensions: page 6/55 Application schemes: page 6/56 6/35 Characteristics 6 Pendant control stations Double insulated, type XAC B For power circuits (direct switching) Environment 1 2 3 4 Conformity to standards Product certifications Standard version EN/IEC 60947-5-1 EN/IEC 60204-32, UL 508, CSA C22-2 n° 14 EN/IEC 60947-5-5 and EN/ISO 13850: 2006 for versions with trigger action Emergency stop EN/IEC 60947-3 CSA type 4 Protective treatment Standard version “TH” Ambient air temperature For storage For operation Vibration resistance - 40…+ 70 - 25…+ 70 15 gn (10…500 Hz) conforming to IEC 60068-2-6 Shock resistance 100 gn conforming to IEC 60068-2-27 Electric shock protection Class II conforming to IEC 61140 Degree of protection IP 65 conforming to IEC 60529 Mechanical durability (in millions of operating cycles) Enclosure 1 except for XAC B91p and XAC CB92p: 0.4 Double insulated glass-reinforced polyester (colour: yellow) Cable entry Rubber sleeve with stepped entry diameter for cable Ø 10…Ø 22 mm Contact block characteristics Thermal current (lthe) 5 °C °C XES D1191, XES D1291 XES D2201, XES D2241, XES D2251 Rated insulation voltage (Ui) XES Dpppp XAC Sp99 XES D1ppp XES D2ppp Rated impulse withstand voltage (U imp) A A 12 20 V V V V kV 500, degree of pollution 3, conforming to IEC 60947-1 400, degree of pollution 3, conforming to IEC 60947-1 600, conforming to CSA 300, conforming to CSA 6, conforming to IEC 60947-1 Contact operation 6 Operating force Snap action XES D1ppp XES D2ppp Terminal referencing Short-circuit protection XES D1ppp XES D2ppp Connection 7 Operational power mm2 3 phases, 2 poles XES D1ppp 3 phases, 3 poles XES D2ppp 3 phases, 3 poles, isolating block XAC Sp99 3 phases, 2 poles XES D1ppp 8 9 10 N N 3 phases, 3 poles XES D2ppp 3 phases, 2 poles Mechanical durability (in millions of operating cycles) XES D1ppp Utilisation categories AC-3 and AC-4 conforming to EN/IEC 60947-3 Appendix A Duty cycle comprising 75% AC-3, 3 phases, 3 poles 25% AC-4 Operating rate: 600 operating cycles XES D2ppp per hour Load factor: 0.4 References: pages 6/37 and 6/38 6/36 Dimensions: page 6/55 17 32 By numbers conforming to CENELEC EN 50005 10 A maximum cartridge fuse type aM 12 A maximum cartridge fuse type aM Captive screw clamp terminals Clamping capacity: 1 x 2.5 or 2 x 1.5 with or without cable end Utilisation categories AC-3 and AC-4 conforming to EN/IEC 60947-3 Appendix A 2.2 kW-240 V 2.2 kW-400 V 3 kW-240 V 3 kW-400 V Utilisation category AC-23B 3 kW-400 V CSA certification 2 hp-240 V 5 hp-400 V 3 hp-600 V 3 hp-240 V 1.5 kW-240 V = 0.5 2.2 kW-240 V = 0.3 1.5 kW-400 V = 0.8 2.2 kW-400 V = 0.3 3 kW-240 V = 0.7 3 kW-400 V = 1 Application schemes: pages 6/56 and 6/57 6 References 6 Pendant control stations 6 Double insulated, type XAC B For power circuits (direct switching) Complete stations “ready for use” Functions Number of operators DF565569 DF565568 For control of single-speed motors 2 mechanically interlocked XAC B3195 XAC B3205 DF565571 XAC B219 XAC B220 DF565570 2 mechanically interlocked + 1 trigger action latching Emergency stop Ø 40 mm operator ZA2 BS844 Contact blocks Per direction Maximum operational power/400 V Reference For Emergency stop – 2.2 kW XAC B219 kg 0.355 3-pole XES D2201(1) – 3 kW XAC B220 0.355 2-pole XES D1191(1) 1 N/C + N/C + N/C XAC S499 2.2 kW XAC B3195 r 0.940 3-pole XES D2201(1) 1 N/C + N/C + N/C XAC S499 3 kW XAC B3205 r 1.000 2-pole XES D1191(1) – 2.2 kW XAC B491 1.200 3-pole XES D2201(1) – 3 kW XAC B493 1.330 2-pole XES D1191(1) 1 N/C + N/C + N/C XAC S499 2.2 kW XAC B4916 r 1.260 3-pole XES D2201(1) 1 N/C + N/C + N/C XAC S499 3 kW XAC B4936 r 1.390 2-pole XES D1191(1) 1 N/C + N/C + N/C XAC S3991 2.2 kW XAC B4915 r 1.350 3-pole XES D2201(1) 1 N/C + N/C + N/C XAC S3991 3 kW XAC B4935 r 1.480 2-pole XES D1191(1) Weight 1 2 3 4 4 mechanically interlocked between pairs XAC B4916 XAC B4936 4 mechanically interlocked between pairs + 1 trigger action latching Emergency stop Ø 40 mm operator ZA2 BS844 DF565572 XAC B491 XAC B493 4 mechanically interlocked between pairs + 1 trigger action latching Emergency stop Ø 40 mm operator ZA2 BS844 mounted in base 5 6 7 8 (1) Trigger action mechanically latching Emergency stop pushbuttons conform to standards EN/IEC 60204-32, EN/ISO 13850: 2006, Machinery directive 98/37/EC and standard EN/IEC 60947-5-5. 9 XAC B4915 XAC B4935 10 r Available 3rd quarter of 2011 Characteristics: page 6/36 Dimensions: page 6/55 Application schemes: pages 6/56 and 6/57 6/37 References (continued) 6 Pendant control stations 6 Double insulated, type XAC B For power circuits (direct switching) Complete stations “ready for use” DF565573 1 For control of single-speed motors (continued) Functions Number of operators 6 mechanically interlocked between pairs 2 6 mechanically interlocked between pairs + 1 trigger action latching Emergency stop Ø 40 mm operator ZA2 BS844 3 4 XAC B691 XAC B693 DF565574 DF565575 6 mechanically interlocked between pairs + 1 trigger action latching Emergency stop Ø 40 mm operator ZA2 BS844 mounted in base 5 Contact blocks Per direction Maximum operational power/400 V Reference For Emergency stop – 2.2 kW XAC B691 kg 1.350 3-pole XES D2201(1) – 3 kW XAC B693 1.550 2-pole XES D1191(1) 1 N/C + N/C + N/C XAC S499 2.2 kW XAC B6916 r 1.410 3-pole XES D2201(1) 1 N/C + N/C + N/C XAC S499 3 kW XAC B6936 r 1.610 2-pole XES D1191(1) 1 N/C + N/C + N/C XAC S3991 2.2 kW XAC B6915 r 1.500 3-pole XES D2201(1) 1 N/C + N/C + N/C XAC S3991 3 kW XAC B6935 r 1.700 Maximum operational power/400 V Reference 2.2 kW XAC B229 kg 0.405 2.2 kW XAC B3295 r 0.990 2-pole XES D1191(1) Weight For control of 2-speed motors Functions Number of operators 6 2 mechanically interlocked Contact blocks Per direction 2-pole XES D1291(1) For Emergency stop – Weight 7 XAC B6915 XAC B6935 XAC B6916 XAC B6936 DF565577 DF565576 8 2 2-pole mechanically XES D1291(1) interlocked + 1 trigger action latching Emergency stop Ø 40 mm operator ZA2 BS844 1 N/C + N/C + N/C XAC S499 (1) Trigger action mechanically latching Emergency stop pushbuttons conform to standards EN/IEC 60204-32, EN/ISO 13850: 2006, Machinery directive 98/37/EC and standard EN/IEC 60947-5-5. 9 XAC B229 XAC B3295 10 r Available 3rd quarter of 2011 Characteristics: page 6/36 6/38 Dimensions: page 6/55 Application schemes: pages 6/56 and 6/57 References 6 Pendant control stations 6 Double insulated, type XAC B For control or power circuits Empty enclosures DF565578 DF565579 Empty enclosures for control circuits or power circuits (1) XAC B020 Description Empty enclosures (1) Double insulated for “Small hoist” applications Operator cut-out centres: 40 mm Number of cut-outs 2 Cut-out in base of enclosure Without Reference XAC B020 Weight kg 0.760 3 Without XAC B030 0.760 1 2 XAC B030 DF565581 DF565580 Protective cable sleeve For cable Ø 7…13 mm Empty enclosures (1) Double insulated for “General purpose” applications Operator cut-out centres: 40 mm For cable Ø 10…22 mm 2 4 Without XAC B02 0.760 With XAC B021 0.760 Without XAC B04 1.000 With XAC B041 1.000 Without XAC B06 1.160 With XAC B061 1.160 Without XAC B08 1.330 With XAC B081 1.330 3 4 XAC B04p DF565583 DF565582 XAC B02p 6 8 XAC B06p 5 6 DF565584 7 12 in 2 rows of 6 Without XAC B12 1.460 With XAC B121 1.460 XAC B08p (1) Enclosure comprising: - the enclosure, - protective cable sleeve, - cable tie (for tightening sleeve onto cable), - internal cable clamp, - suspension ring, - bezel tightening key. 9 XAC B12p Characteristics: pages 6/34 and 6/36 8 10 Dimensions: page 6/55 Application schemes: pages 6/56 and 6/57 Presentation: page 6/58 6/39 References (continued) 6 Pendant control stations 6 Double insulated, type XAC B For control or power circuits Empty enclosures Empty enclosures for control circuits or power circuits (1) (continued) Description DF565580 DF565581 1 Empty enclosures (1) Double insulated for “General purpose” applications Operator cut-out centres: 40 mm Protective cable sleeve For cable Ø 22…35 mm Number of cut-outs 2 Cut-out in base of enclosure Without Reference With XAC B0215 0.960 Without XAC B045 1.200 With XAC B0415 1.200 Without XAC B065 1.360 With XAC B0615 1.360 Without XAC B085 1.530 With XAC B0815 1.530 Without XAC B125 1.660 With XAC B1215 1.660 XAC B025 Weight kg 0.960 2 4 3 XAC B04pp DF565583 DF565582 XAC B02pp 6 4 8 5 6 DF565584 XAC B06pp 12 in 2 rows of 6 XAC B08pp 7 (1) Enclosure comprising: - the enclosure, - protective cable sleeve, - cable tie (for tightening sleeve onto cable), - internal cable clamp, - suspension ring, - bezel tightening key. 8 XAC B12pp 9 10 Characteristics: pages 6/34 and 6/36 6/40 Dimensions: page 6/55 Application schemes: pages 6/56 and 6/57 Presentation: page 6/58 References 6 Pendant control stations 6 Double insulated, type XAC B Metal, type XAC M For control circuits Empty enclosures (XAC M: products for maintenance purposes only) DF565585 Empty enclosures for control circuits (1) Description Empty enclosures (1) Double insulated for “General purpose” applications Operator cut-out centres: 30 mm Protective cable sleeve For cable Ø 10…22 mm Number of cut-outs 12 in 1 row Cut-out in base of enclosure Without Reference With XAC B1201 XAC B120 Weight kg 1.330 1 1.330 2 For cable Ø 22…35 mm Empty enclosures (1) Metal for “General purpose” applications Operator cut-out centres: 40 mm For cable Ø 10…22 mm 12 in 1 row 4 Without XAC B1205 1.530 With XAC B12015 1.530 Without XAC M04 1.540 With XAC M041 1.540 Without XAC M08 2.210 With XAC M081 2.210 Without XAC M045 1.740 With XAC M0415 1.740 3 4 XAC B120 DF565586 DF565587 8 For cable Ø 22…35 mm 4 5 6 7 8 XAC M04p Without XAC M085 2.410 With XAC M0815 2.410 XAC M08p 8 Variable composition stations, factory assembled Use the order form on page 6/59 to define the required configuration Equipment: contact blocks, operating heads (control and signalling), complementary accessories 9 See separate components, pages 6/42 to 6/54 (1) Enclosure comprising: - the enclosure, - protective cable sleeve for cable Ø 10…22 mm or Ø 22…35 mm, - cable tie (for tightening sleeve onto cable), - internal cable clamp, - suspension ring, - bezel tightening key. Characteristics: pages 6/34 Dimensions: page 6/55 Application schemes: pages 6/56 and 6/57 10 Presentation: page 6/58 6/41 References 6 Pendant control stations 6 Double insulated, type XAC B Metal, type XAC M For control circuits Separate components and spare parts Contact blocks for front mounting, slow break Description 1 Application Function Scheme Operator centres mm Reference Weight 30 or 40 XEN C1111 0.020 30 or 40 XEN C1121 0.020 30 or 40 XEN C1131 0.020 30 or 40 XEN C1141 0.020 30 or 40 XEN C1151 0.020 30 or 40 XEN B1491 0.050 30 or 40 XEN B1181 0.050 30 or 40 XEN B1191 0.050 30 XEN D1611 0.110 40 (1) XEN D2611 0.110 30 XEN D1621 0.110 40 (1) XEN D2621 0.110 kg Single-speed N/O 2 N/C 9 2 step N/O + N/O staggered 23 24 21 22 13 11 12 13 23 24 23 24 43 13 24 43 44 23 14 44 14 11 23 12 24 31 32 33 34 31 23 2-speed 24 XEN D2611 43 7 Single-speed N/O + N/O simultaneous 44 DF565590 Double block 2 spring return operators mechanically interlocked 32 2 step C/O + N/O staggered 6 8 2 step N/O + N/O staggered 13 2-speed 14 XEN B1181 33 5 34 C/O + N/O 13 N/C + N/O 4 14 DF565589 N/C + N/C 33 3 34 N/O + N/O 14 12 XEN C1111 11 14 DF565588 Single block 1 spring return operator 13 Spring return (1) These contact blocks cannot be mounted in enclosures XAC B120p (12 operators in 1 row). 10 Characteristics: pages 6/34 6/42 Dimensions: page 6/55 Application schemes: pages 6/56 Presentation: page 6/58 References (continued) 6 Pendant control stations 6 Double insulated, type XAC B Metal, type XAC M For control circuits Separate components and spare parts Contact blocks for front mounting, slow break (continued) Description Application Function Scheme Operator centres mm Reference Weight 30 XEN D1631 0.110 40 (1) XEN D2631 0.110 30 XEN D1641 0.110 kg 1 23 24 53 54 24 53 54 23 14 43 44 31 32 61 62 14 43 13 32 61 44 31 2 step C/O + N/O staggered DF565592 2-speed 62 DF565593 XEN D2641 Single-speed C/O + N/O 13 Spring return (continued) Double block 2 spring return operators mechanically interlocked 3 40 (1) XEN D2641 0.110 30 XEN D3801 0.170 40 (1) XEN D4801 0.170 24 24 23 24 23 12 11 12 11 Single-speed N/C + N/O DF565591 Double block 2 latching operators 4 5 24 23 11 12 11 12 XEN D3801 23 Latching Single-speed N/C + N/O Double block 1 latching operator released by 1 spring return operator 2 30 XEN D3811 0.170 40 (1) XEN D4811 0.170 Operator centres mm Reference 40 (1) XES B2011 0.030 40 (1) XES D1181 0.140 40 (1) XES D1281 0.190 6 Contact blocks for front mounting, snap action Description Application Function Scheme XES B2011 Weight kg 1 3 4 13 Dimensions: page 6/55 Application schemes: pages 6/56 33 9 23 24 23 43 44 10 (1) These contact blocks cannot be mounted in enclosures XAC B120p (12 operators in 1 row). (2) Only for mounting with operators XAC B91pp. Characteristics: pages 6/34 8 14 21 22 13 11 21 24 XES D1181 14 C/O + N/O staggered 12 2-speed 7 34 Single-speed C/O 2 Double block 2 spring return operators mechanically interlocked 11 Single-speed C/O 12 Single block 1 spring return operator (2) 22 DF565594 Spring return Presentation: page 6/58 6/43 References (continued) 6 Pendant control stations 6 Double insulated, type XAC B Metal, type XAC M For control circuits Separate components and spare parts Contact blocks for front mounting (1) N/O N/C N/C + N/O 23 24 21 22 13 14 11 12 11 N/C + N/C 23 3 12 N/O + N/O 4 XAC S411 Weight kg 0.070 XAC S412 0.070 XAC S413 0.070 XAC S414 0.070 XAC S415 0.070 Reference XAC S4111 Weight kg 0.100 XAC S4121 0.100 XAC S4131 0.100 XAC S4141 0.100 XAC S4151 0.100 12 XAC S41p 24 2 Reference 14 Spring return Slow break Operator centres 30 or 40 mm Scheme 13 Function 11 Description 530240 Contact blocks for base mounting (1) Function 530240 Spring return Slow break N/O 14 5 Scheme 13 Description 13 23 24 N/O + N/O 6 14 12 N/C 11 1 11 21 22 11 23 N/C + N/O 12 7 24 N/C + N/C 12 XAC S4111 Pilot light bodies for front mounting 8 Description Supply voltage DF565595 Direct supply Bulb not included (2) y 400 V Scheme X1 Reference XAC V06 Weight kg 0.050 XAC V07 0.055 X2 9 XAC V06 Direct supply, through resistor Incandescent BA 9s base fitting 130 V bulb included 230 V X1 X2 (1) Mounting with operating heads ZA2 Bppp (see page 6/47). (2) Bulb type for use with direct supply units: BA 9s base fitting incandescent bulb U y 130 V or neon bulb 110 V y U y 400 V. Maximum power: 2.6 W, maximum Ø: 11 mm, maximum length: 26 mm. See page 6/50. 10 Characteristics: pages 6/34 6/44 Dimensions: page 6/55 Application schemes: pages 6/56 Presentation: page 6/58 References 6 Pendant control stations 6 Double insulated, type XAC B For power circuits (direct switching) Separate components and spare parts Contact blocks, snap action 530369 23 24 51 52 54 61 62 3 64 43 23 24 44 33 43 84 43 84 44 44 44 44 34 73 33 74 23 73 34 63 33 74 23 73 34 63 74 24 64 24 24 63 64 13 14 53 54 13 14 53 64 N/O + N/O 3 kW + N/O + 1 N/O staggered auxiliary contact (1) 54 XES D2201 0.190 1 0.200 4 13 N/O + N/O 3 kW + N/O + 1 N/O simultaneous auxiliary contact (1) XES D1291 XES D2201 14 3 kW 53 N/O + N/O + N/O 54 530368 Double block Single3-pole speed 2 spring return operators mechanically interlocked (operator centres: 40 mm) XES D1191 Weight kg 0.140 2 43 44 14 33 34 13 2.2 kW 34 XES D1191 N/O + N/O + 1 C/O staggered auxiliary contact (1) 14 2-speed N/O + N/O Reference 33 DF565594 Double block Single2-pole speed 2 spring return operators mechanically interlocked (operator centres: 40 mm) Max. power/ Scheme 400 V 2.2 kW 13 Application Function 23 Description XES D2241 0.210 5 XEN D2251 0.210 6 Isolating block, slow break In the interests of safety, it is imperative that these isolating blocks only be used with a stay put or latching type operating head to ensure complete isolation when the pendant station is not in use. 31 32 31 31 32 21 32 530366 22 3 kW 21 Emergency N/C + N/C stop + N/C with positive opening operation 22 In base (3) XAC S499 21 3 kW 22 Emergency N/C + N/C stop + N/C with positive opening operation 11 On front 30 mm centres (2) 12 Emergency N/C + N/C stop + N/C with positive opening operation Reference 11 On front 40 mm centres (2) Scheme 12 530391 XAC S399 Max. power/ 400 V 3 kW 11 Application Function 12 Mounting position Weight kg XAC S399 0.100 XAC S499 0.100 XAC S3991 0.110 (1) Auxiliary contacts are slow break. (2) Mounting with operating heads ZA2 Bppp, except ZA2 BDp and ZA2 BGp (see page 6/47). (3) Mounting with operating head ZA2 BS944 (see page 6/47). Dimensions: page 6/55 Application schemes: pages 6/56 and 6/57 8 9 10 XAC S3991 Characteristics: pages 6/36 7 Presentation: page 6/58 6/45 References 6 Pendant control stations 6 Double insulated, type XAC B Metal, type XAC M For control or power circuits Separate components and spare parts 1 DF565596 Booted operators XAC B911p 2 For use with contact block XEN Bpppp XEN Cpppp XEN Dpppp XES B2011 XES D2201 XES D2241 XES D2251 Travel 4 mm 3 Operating temperature - 25…+ 70 °C (1) - 40…+ 70 °C (2) 5 DF565597 4 XES D1181 XES D1191 XES D1281 XES D1291 16 mm - 25…+ 70 °C (1) XAC B921p 6 - 40…+ 70 °C (2) 7 8 Colour of insert White Sold in lots of 10 Unit reference XAC B9111 Weight kg 0.005 Black 10 XAC B9112 0.005 Green 10 XAC B9113 0.005 Red 10 XAC B9114 0.005 Yellow 10 XAC B9115 0.005 Blue 10 XAC B9116 0.005 Brown 10 XAC B9119 0.005 White 10 XAC B9121 0.005 Black 10 XAC B9122 0.005 Green 10 XAC B9123 0.005 Red 10 XAC B9124 0.005 Yellow 10 XAC B9125 0.005 Blue 10 XAC B9126 0.005 Brown 10 XAC B9129 0.005 White 10 XAC B9211 0.005 Black 10 XAC B9212 0.005 Green 10 XAC B9213 0.005 Red 10 XAC B9214 0.005 Yellow 10 XAC B9215 0.005 Blue 10 XAC B9216 0.005 Brown 10 XAC B9219 0.005 White 10 XAC B9221 0.005 Black 10 XAC B9222 0.005 Green 10 XAC B9223 0.005 Red 10 XAC B9224 0.005 Yellow 10 XAC B9225 0.005 Blue 10 XAC B9226 0.005 Brown 10 XAC B9229 0.005 Booted operators (silicone boot) DF565598 9 For use with contact block XAC S41p Operating temperature - 25…+ 70 °C ZA2 BPp 10 Colour of boot Black Reference ZA2 BP2 Weight kg 0.015 Green ZA2 BP3 0.015 Red ZA2 BP4 0.015 Yellow ZA2 BP5 0.015 Blue ZA2 BP6 0.015 (1) Polychloroprene boots. (2) Silicone boots. Characteristics: pages 6/34 and 6/36 6/46 Dimensions: page 6/55 Application schemes: pages 6/56 and 6/57 Presentation: page 6/58 References 6 Pendant control stations 6 Double insulated, type XAC B Metal, type XAC M For control or power circuits Separate components and spare parts DF538492 Operating heads for front or base mounting (1) Description DF538493 ZA2 BS844 530382 ZA2 BS944 530383 ZA2 BDp 530381 ZA2 BGp ZA2 BBp Colour Type Reference Red Ø 30 mm ZA2 BS834 Weight kg 0.028 Ø 40 mm ZA2 BS844 0.033 Ø 30 mm ZA2 BS934 0.060 Ø 40 mm ZA2 BS944 0.065 Black 2 position, stay put 3 position, stay put (5) ZA2 BD2 ZA2 BD3 0.018 0.018 – Key switches (key n° 455) (3) Key withdrawal in left and right-hand positions Key switches – (key n° 455) (3) Key withdrawal in left-hand position Key switches – (key n° 455) (3) Spring return from right to left Key withdrawal in left-hand position – Key switches (key n° 455) (4) (3) Key withdrawal in centre position Wobblesticks (6) Black Operates in all directions for Red fast stop 2 position, stay put 3 position, stay put (5) ZA2 BG4 ZA2 BG5 0.042 0.042 2 position, stay put ZA2 BG2 0.042 2 position ZA2 BG6 0.042 Trigger action latching Emergency stop (2) Turn to release (Emergency stop function) Trigger action latching Emergency stop (2) (3) Key release (n° 455) Key withdrawal in rest (unactuated) position (Emergency stop function) Selector switches, standard handle (4) Red Colour Mushroom head, latching Red Key release (n° 455) Key withdrawal in rest (unactuated) position (Emergency stop function) 3 position, stay put (5) ZA2 BG3 0.042 – – ZA2 BB2 ZA2 BB4 0.060 0.060 Type Reference 3 Ø 40 mm ZA2 BS14 5 Weight kg 0.065 6 Pilot light heads Description 2 4 Operating head for isolating block Description 1 Colour Reference Weight kg For use with incandescent bulbs 530390 Lens cap with fixing bezel White ZA2 BV01 0.015 Green ZA2 BV03 0.015 Red ZA2 BV04 0.015 Yellow ZA2 BV05 0.015 Blue ZA2 BV06 0.015 Clear ZA2 BV07 0.015 Green ZA2 BV033 0.015 Red ZA2 BV043 0.015 Yellow ZA2 BV053 0.015 Clear ZA2 BV073 0.015 7 8 For use with neon bulbs Lens cap with fixing bezel ZA2 BV0p (1) The technical characteristics of pendant control stations XAC B and XAC M can only be guaranteed by using the operating heads ZA2 Bpp listed above. (2) Trigger action mechanically latching Emergency stop pushbuttons conform to standards EN/IEC 60204-32, EN/ISO 13850: 2006, Machinery directive 98/37/EC and standard EN/IEC 60947-5-5. (3) Other key numbers available on request, please consult your Regional Sales Office. (4) Selector switches or key switches with other mechanical functions: please consult your Regional Sales Office. (5) Only suitable for front mounting. (6) Base mounting recommended. Characteristics: pages 6/34 and 6/36 Dimensions: page 6/55 Application schemes: pages 6/56 and 6/57 Presentation: page 6/58 6/47 9 10 Characteristics 6 Pendant control stations 6 Double insulated, type XAC B Metal, type XAC M For control circuits Separate components: pushbuttons with analogue output (1) Environment 1 Conformity to standards EN/IEC 60947-5-1 Ambient air temperature For storage For operation °C °C - 40…+ 70 - 25…+ 70 IP 65 conforming to IEC 60529 Pushbutton operator travel mm 11 Operating force N Mechanical durability (in millions of operating cycles) Connection 4 (start of travel) 9 (end of travel) 1 mm2 Terminal connectors, maximum clamping capacity: 2 x 1.5 mm2 or 1 x 2.5 mm2 Thermal current (lthe) A 6 Rated insulation voltage (Ui) V 250, degree of pollution 3, conforming to IEC 60947-1 Degree of protection 2 Contact block characteristics 3 Rated operational characteristics conforming to 947-5-1 Appendix C Utilisation categories AC-15 and DC-13 4 a.c. supply a 50/60 Hz Power broken in VA for 1 million operating cycles Voltage V 48 110 30 30 VA o o Inductive circuit d.c. supply c Power broken in W for 1 million operating cycles Voltage V 48 110 48 12 o W 230 30 Analogue circuit characteristics Type of current 5 d.c. Rated supply voltage V 15 Voltage limits V 14…18 Current consumption mA < 15 Analogue signal output curves and schemes Analogue signal output curves 6 Equivalent output schemes with 15 V supply voltage XEA p15361 XEA p25361 11 7 11 Travel on pushbutton operator (mm) 10 12 23 5 24 33 34 XEA 15631 - 10 V 8 11 – 15 V 12 1 kΩ 0 23 S 10 kΩ 10 V 0V 34 + 10 V Note: supply voltage = 15 V, output voltage = 10 V (if supply voltage < 15 V, output voltage < 10 V) Contact state 9 23 - 24 11 - 12 33 - 34 0,5 mm 0 0,4 mm contact closed contact open 11,5 mm (1) Pushbuttons providing an analogue output signal proportional to the distance travelled by the pushbutton operator. 10 References: page 6/49 6/48 Dimensions: page 6/49 0 10 kΩ 10 V 1 kΩ S 24 33 XEA 25361 0 0V + 15 V Pendant control stations References, dimensions 6 6 Double insulated, type XAC B Metal, type XAC M For control circuits Separate components: pushbuttons with analogue output (1) References 530386 Complete pushbuttons (body + operating head), non booted (2) Supply voltage Contact block Reference 0…- 15 V N/C + N/O at start of travel N/O at end of travel XEA C15361 Weight kg 0.065 0…+ 15 V N/C + N/O at start of travel N/O at end of travel XEA C25361 0.065 XEA Cp5361 1 2 Complete pushbuttons (body + operating head), booted (2) 530392 Supply voltage XEA Bp5361 Contact block Reference 0…- 15 V N/C + N/O at start of travel N/O at end of travel XEA B15361 Weight kg 0.065 0…+ 15 V N/C + N/O at start of travel N/O at end of travel XEA B25361 0.065 For use with Reference XEA Cp5361 ZA2 BZ905 XEA Bp5361 XAC X1 Mounting accessories Description 530306 3 Tightening key for fixing nut Weight kg 0.060 0.010 ZA2 BZ905 5 530305 Separate components and spare parts Description Booted operator (Sold in lots of 10) 4 Colour of insert Unit reference White XAC B9111 Weight kg 0.005 Black XAC B9112 0.005 6 DF565601 XAC X1 (1) Pushbuttons providing an analogue output signal proportional to the distance travelled by the pushbutton operator. (2) Pushbutton supplied with 1 white insert and 1 black insert. XAC B9112 7 Dimensions XEA Bp5361 XEA Cp5361 Panel cut-out = = 30 = 26 55 = 30 8 30 (1) 18 44 E 44 E 17 0 Ø22,3 +0,4 9 26 55 E = support panel thickness, 1 to 3.5 mm. (1) Minimum fixing centres between 2 operators. 10 Characteristics: page 6/48 6/49 References 6 Pendant control stations 6 Double insulated, type XAC B Metal, type XAC M For control or power circuits Separate components and spare parts Bulbs Description 530307 1 DL1 Cpppp Voltage Incandescent BA 9s base fitting Maximum power: 2.6 W Maximum Ø: 11 mm Maximum length: 28 mm 530308 2 DL1 CFppp 3 Neon BA 9s base fitting Maximum power: 2.6 W Maximum Ø: 11 mm Maximum length: 28 mm Unit reference 6V Sold in lots of 10 DL1 CB006 Weight kg 0.002 12 V 10 DL1 CE012 0.002 24 V 10 DL1 CE024 0.002 48 V 10 DL1 CE048 0.002 130 V 10 DL1 CE130 0.002 120 V 10 DL1 CF110 0.002 230 V 10 DL1 CF220 0.002 400 V 10 DL1 CF380 0.002 Accessories for booted operators Description 530311 Boots with circlip, without coloured insert 4 Travel 4 mm 16 mm XAC B91p 530310 5 Coloured inserts for booted operators (4 and 16 mm travel) 6 530309 XAC B92p XAC B90p Material/ Colour Polychloroprene Operating temperature - 25…+ 70° C Sold in lots of 10 Unit reference XAC B911 Weight kg 0.002 Silicone - 40…+ 70° C 10 XAC B912 0.002 Polychloroprene - 25…+ 70° C 10 XAC B921 0.002 Silicone - 40…+ 70° C 10 XAC B922 0.002 White – 10 XAC B901 0.001 Black – 10 XAC B902 0.001 Green – 10 XAC B903 0.001 Red – 10 XAC B904 0.001 Yellow – 10 XAC B905 0.001 Blue – 10 XAC B906 0.001 Brown – 10 XAC B909 0.001 7 8 9 10 Characteristics: pages 6/34 and 6/36 6/50 Dimensions: page 6/55 Application schemes: pages 6/56 and 6/57 Presentation: page 6/58 References (continued) 6 Pendant control stations 6 Double insulated, type XAC B Metal, type XAC M For control or power circuits Separate components and spare parts Description 530313 530312 Complementary accessories Protective cable sleeve with cable tie (for tightening sleeve onto cable) XAC B913 For use with Reference Enclosures XAC B219 and XAC B220 (2 operators) For cable Ø 7…13 mm XAC B913 Weight kg 0.065 Enclosures XAC Bppp with 4 to 12 operators and XAC Mppp with 4 and 8 operators For cable Ø 10…22 mm XAC B960 0.110 For cable Ø 22…35 mm XAC B965 0.160 Blanking plug with seal and fixing nut – ZB2 SZ3 0.005 Adaptor for use with protective cable sleeve for cable Ø 10…22 mm Self-supporting cable type BBAP XAC B961 0.025 Lower support ring Single row enclosures XAC B and XAC M XAC B971 0.015 2 row enclosures XAC B XAC B972 0.020 Emergency stop pushbutton XAC B982 0.050 For use with Reference Bezels XAC X1 Weight kg 0.010 Units mounted in base of enclosure XAC X905 0.015 BA 9s base fitting bulbs XBF X13 0.003 1 2 3 530314 XAC B960 DF565602 XAC B971 Protective guards for base mounted units Tools XAC B972 DF565604 Description Tightening key Bulb extractor 530319 530318 XAC B982 XAC X1 4 5 6 7 8 XAC X905 9 10 Characteristics: pages 6/34 and 6/36 Dimensions: page 6/55 Application schemes: pages 6/56 and 6/57 Presentation: page 6/58 6/51 References 6 Pendant control stations 6 Double insulated, type XAC B Metal, type XAC M For control or power circuits Legends 30 x 40 mm (with symbols conforming to NF E 52-124) DF565666 1 Symbol Reference Vertical mounting 40 mm centres Raise, slow ZB2 BY4951 0.001 Raise, fast ZB2 BY4952 ZB2 BY4902 0.001 Raise, slow-fast ZB2 BY4953 ZB2 BY4903 Right, slow ZB2 BY4901 kg Symbol Reference Horizontal mounting 30 mm centres Weight kg Lower, fast ZB2 BY2955 ZB2 BY2905 0.001 0.001 Lower, slow-fast ZB2 BY2956 ZB2 BY2906 0.001 ZB2 BY4907 0.001 Left, slow ZB2 BY2904 ZB2 BY2910 0.001 Right, fast ZB2 BY4902 ZB2 BY4908 0.001 Left, fast ZB2 BY2905 ZB2 BY2911 0.001 Horizontal mounting Right, slow-fast 30 mm centres ZB2 BY4903 ZB2 BY4909 0.001 Left, slow-fast ZB2 BY2906 ZB2 BY2912 0.001 Forward, slow ZB2 BY4963 ZB2 BY4913 0.001 Reverse, slow ZB2 BY2966 ZB2 BY2916 0.001 Forward, fast ZB2 BY4964 ZB2 BY4914 0.001 Reverse, fast ZB2 BY2967 ZB2 BY2917 0.001 Forward, slow-fast ZB2 BY4965 ZB2 BY4915 0.001 Reverse, slow-fast ZB2 BY2968 ZB2 BY2918 0.001 Slew right, slow ZB2 BY4919 ZB2 BY4919 0.001 Slew left, slow ZB2 BY2922 ZB2 BY2922 0.001 Slew right, fast ZB2 BY4920 ZB2 BY4920 0.001 Slew left, fast ZB2 BY2923 ZB2 BY2923 0.001 Slew right, slow-fast ZB2 BY4921 ZB2 BY4921 0.001 Slew left, slow-fast ZB2 BY2924 ZB2 BY2924 0.001 ZB2 BY4933 ZB2 BY4933 0.001 ZB2 BY4934 ZB2 BY4934 0.001 ZB2 BY4982 ZB2 BY4932 0.001 Start-Klaxon ZB2 BY4985 ZB2 BY4935 0.001 ZB2 BY4980 ZB2 BY4930 0.001 ZB2 BY2931 0.001 40 DF565665 5 Vertical mounting 40 mm centres ZB2 BY4901 Symbol Reference Vertical mounting 40 mm centres Lower, slow ZB2 BY2954 0.001 3 4 Weight ZB2 BY2904 30 2 Symbol Reference Horizontal mounting 30 mm centres White background, black symbol 6 Black background, white symbol 7 Red background, white symbol 8 Slow Fast 9 Klaxon Start 10 Characteristics: pages 6/34 and 6/36 6/52 Stop Dimensions: page 6/55 Application schemes: pages 6/56 and 6/57 ZB2 BY2931 Presentation: page 6/58 References 6 Pendant control stations 6 Double insulated, type XAC B Metal, type XAC M DF565667 For control or power circuits Legends 30 x 40 mm White Black Text Reference Red Weight kg Text Reference Weight kg 1 b Start functions: white characters on black background b Stop functions: white characters on red background Blank Black or red background DF565668 ZB2 BY2101 ZB2 BY2101 0.001 White or yellow background ZB2 BY4101 With French text With English text For pushbuttons For pushbuttons 0.001 2 Marche ZB2 BY2103 0.001 Start ZB2 BY2303 0.001 Arrêt ZB2 BY2104 0.001 Stop ZB2 BY2304 0.001 Avant ZB2 BY2105 0.001 Forward ZB2 BY2305 0.001 Arrière ZB2 BY2106 0.001 Reverse ZB2 BY2306 0.001 Montée ZB2 BY2107 0.001 Up ZB2 BY2307 0.001 Descente ZB2 BY2108 0.001 Down ZB2 BY2308 0.001 Droite ZB2 BY2109 0.001 Right ZB2 BY2309 0.001 Gauche ZB2 BY2110 0.001 Left ZB2 BY2310 0.001 En service ZB2 BY2111 0.001 On ZB2 BY2311 0.001 Hors service ZB2 BY2112 0.001 Off ZB2 BY2312 0.001 Sous tension ZB2 BY2126 0.001 Power on ZB2 BY2326 0.001 Lent ZB2 BY2127 0.001 Slow ZB2 BY2327 0.001 Vite ZB2 BY2128 0.001 Fast ZB2 BY2328 0.001 Klaxon ZB2 BY2125 0.001 – – Arrêt-Marche ZB2 BY2166 0.001 – – Hors-En ZB2 BY2167 0.001 Off-On ZB2 BY2367 Black White Yellow ZB2 BY4101 For selector switches 3 4 5 – For selector switches – 6 0.001 With special texts b Specify text when ordering, b 2 lines maximum, 11 characters per line. White characters on black background White characters on red background Other versions ZB2 BY2002 7 0.001 Black characters on white background ZB2 BY2004 0.001 Black characters on yellow background Legends with texts in other languages. Please consult your Regional Sales Office. ZB2 BY4001 0.001 ZB2 BY4005 0.001 8 9 10 Characteristics: pages 6/34 and 6/36 Dimensions: page 6/55 Application schemes: pages 6/56 and 6/57 Presentation: page 6/58 6/53 References 6 Pendant control stations 6 Double insulated, type XAC B Metal, type XAC M For control or power circuits Twin legends for tower cranes Legends with white symbols on black background Function 1 Symbol Reference Weight kg Function Symbol Reference Weight kg 40 mm operator centres (for enclosures with 2 to 8 operators and 12 operators in 2 rows) Hoist Raise Lower XAC Y4970 0.002 Long travel Forward Reverse XAC Y4972 0.002 Slew Right Left XAC Y4971 0.002 Trolley Forward Reverse XAC Y4973 0.002 2 3 30 mm operator centres (for enclosures with 12 operators in 1 row) Hoist Raise Lower XAC Y3970 0.002 Long travel Forward Reverse XAC Y3972 0.002 Slew Right Left XAC Y3971 0.002 Trolley Forward Reverse XAC Y3973 0.002 4 5 6 7 8 9 10 Characteristics: pages 6/34 and 6/36 6/54 Dimensions: page 6/55 Application schemes: pages 6/56 and 6/57 Presentation: page 6/58 Dimensions 6 Pendant control stations 6 Double insulated, type XAC B Metal, type XAC M For control or power circuits (XAC M: products for maintenance purposes only) Pendant control stations XAC Bppp (2 to 12-way, 1 row) XAC Mppp (4 to 8-way, 1 row) XAC Bppp (12-way, 2 rows) 1 2 200 40 40 265 XAC Bppp (2 and 3-way) b 85 3 b1 b1 d d 74,5 b 60 4 c 76 c 76 100 (1) 100 (1) 5 Protective cable sleeves internal Ø internal Ø Ø7 Ø10…13 Ø22…26 Ø9 Ø11 Ø13…16 Ø26…29 Ø16…19 Ø19…22 Ø29…32 Ø32…35 internal Ø Ø14 6 7 (1) With mushroom head operator. Number of operators b b1 c d 2 409 220 98 40 Protective guards Lower support rings XAC B982 XAC B971, B972 4 499 310 98 40 6 589 400 98 40 8 679 490 98 40 12 (1 row) 679 490 98 30 12 (2 rows) 593 404 158 40 8 24 48 9 10 Characteristics: pages 6/34 and 6/36 References: pages 6/35 to 6/54 Application schemes: pages 6/56 and 6/57 Presentation: page 6/58 6/55 Pendant control stations Application schemes (typical examples) 6 Double insulated, type XAC B Metal, type XAC M For control or power circuits Control circuits 13 33 34 43 23 24 14 12 21 – S2 A1 A1 A2 – KM2 A2 A1 – KM A2 A2 4 – KM1 – KM1 A2 – KM2 A1 A1 – S2 44 14 23 24 13 – S1 – S1 22 11 11 Contact block XES D1281 12 3 For control of 2-speed reversing motor Contact block XES D1181 21 2 For control of single-speed reversing motor 22 1 KM: high speed contactor Power circuits For control of single-speed reversing motor. 2-phase switching Application example: Combined with 3-pole isolating block XAC S399 or XAC S3991, shown in the unoperated position (pendant station “supplied”), fitted with key release trigger action latching Emergency stop operator (ZA2 BS944). L3 23 13 23 13 6 L3 Q 22 L2 12 L1 21 L2 11 L1 31 5 32 Contact block XES D1191 24 43 14 14 33 24 – S1 – S1 33 43 7 34 44 34 44 – S2 – S2 W V U W V U 8 9 10 Characteristics: pages 6/34 and 6/36 6/56 References: pages 6/35 to 6/54 Dimensions: page 6/55 Presentation: page 6/58 6 Pendant control stations Application schemes (typical examples) (continued) 6 6 Double insulated, type XAC B Metal, type XAC M For control or power circuits Power circuits (continued) For control of 2-speed reversing motor (motors with separate windings only). 2-phase switching Application example: Combined with 3-pole isolating block XAC S399 or XAC S3991, shown in the unoperated position (pendant station “supplied”), fitted with key release trigger action latching Emergency stop operator (ZA2 BS944). 21 23 22 51 24 52 31 11 2 Q 51 23 L3 L3 13 12 L2 13 L1 L2 14 L1 1 32 Contact block XES D1291 43 61 62 33 54 54 52 61 24 43 14 33 – S2 44 – S1 – S1 3 64 34 64 62 44 34 – S2 4 Y Y U1 U2 U1 U2 V1 V2 V1 V2 W1 W2 W1 W2 5 For control of single-speed reversing motor. 3-phase switching, reversing by 2-phase inversion Contact block XES D2201 Contact block XES D2241 with line contactor L1 L2 L3 6 3 2 1 A1 1 – F1 2 4 6 23 33 24 34 7 43 2 – S1 13 33 L3 23 13 L2 A1 – KM1 L1 44 73 84 63 34 73 14 24 63 – S2 53 14 53 – S1 44 74 8 W 64 U V 54 74 W 64 V U 54 – S2 9 Y Y 10 Characteristics: pages 6/34 and 6/36 References: pages 6/35 to 6/54 Dimensions: page 6/55 Presentation: page 6/58 6/57 Presentation 6 Pendant control stations 6 Double insulated, type XAC B Metal, type XAC M For control or power circuits 1 XEA B p5361 XEN C1111 2 XEN D2611 XEA Cp 5361 XAC B911p 3 XAC B921p XES D1pp 1 XES B2011 ZA2 BS834 4 ZA2 BS944 XEN D3801 5 ZB2 BYpppp XEN B1181 ZB2 BY pppp ZA2 BS844 6 XAC S499 ZA2 BS934 XES D22p 1 ZB2 BYpppp 7 8 XAC S399 ZA2 BDp XAC S41p ZA2 BGp XAC V0 p 9 XAC B982 ZA2 BBp XAC S41p1 XAC S3991 ZA2 BV0 p 10 ZA2 BS844 ZB2 SZ3 ZA2 BS944 6/58 Pendant control stations Order form (specimen suitable for photocopying) 6 6 Double insulated, type XAC B Metal, type XAC M (XAC M: products for maintenance purposes only) For control or power circuits Variable composition stations, factory assembled 530343 Customer Company Order N° Delivery date Unit reference of empty enclosure, see pages 6/39 to 6/41 7 8 3 9 4 10 1 Number of identical stations Enclosure price (1) 2 XAC 12 cut-outs, centres: 40 mm 5 11 6 12 16 13 Order N° Enter the order with XAC B09 reference (for enclosures XAC B) or XAC M09 reference (for enclosures XAC M) 14 1 2 Schneider Electric Industries Sales office - Subsidiary Co. Legends see pages 6/52 to 6/54 Contact blocks or pilot light bodies see pages 6/42 to 6/45 Operating heads or pilot light heads or blanking plug see pages 6/46 and 6/47 Reference Reference Reference Unit price Unit price Unit price 3 Total price 1 2 525684 3 4 4 5 14 6 7 1 2 2 to 8 cut-outs, centres: 40 mm 5 9 3 4 10 11 5 6 7 8 8 6 12 13 15 Unit mounted in base of enclosure (if required) 13 Number of heads or blanking plugs to be fitted 525685 Factory assembled: Additional cost XAC 9VA for fitting of 1 head or 1 blanking plug 7 X Complementary accessories, see page 6/51 (cross the appropriate box or boxes) Description Reference 14 1 2 3 4 5 6 7 8 9 10 11 12 12 cut-outs, centres: 30 mm 14 Adaptor for self-supporting cable type BBAP for use with cable entry sleeve Ø 10 to 22 mm 15 Lower support ring for single row enclosures XAC B961 15 Lower support ring for 2 row enclosures XAC B972 16 Protective guard for key release latching mushroom head pushbutton, mounted in base XAC B982 Unit price 8 XAC B971 9 Total price of assembled pendant station (1) Obtain the empty enclosure price. 13 10 15 6/59 Characteristics 6 Pendant control stations 6 Double insulated, type XAC F For control circuits (XAC F: Products for maintenance purposes only) Environment 1 2 3 Conformity to standards Protective treatment Standard version Ambient air temperature For storage For operation EN/IEC 60947-5-1 EN/IEC 60204-32, UL 508, CSA C22-2 n° 14 EN/IEC 60947-5-5 and EN/ISO 13850: 2006 for versions with trigger action Emergency stop EN/IEC 60947-3 “TH” °C °C Vibration resistance - 40…+ 70 - 25…+ 70 15 gn (10…500 Hz) conforming to IEC 60068-2-6 Shock resistance 100 gn conforming to IEC 60068-2-27 Electric shock protection Class II conforming to IEC 61140 Degree of protection IP 65 conforming to IEC 60529 IK 08 conforming to EN 50102 1 Mechanical durability (in millions of operating cycles) Enclosure Double insulated glass-reinforced polyester (yellow) Cable entry 4 Rubber sleeve with stepped entry diameter for cable Ø 10…22 mm or Ø 22…35 mm Contact block characteristics Rated operational characteristics Thermal current (lthe) Rated insulation voltage (Ui) 5 XEN Cpppp, XEN D3ppp, XEN D4ppp, XES B2011, XAC S4, XES D1181, XES D1281 XEN Bpppp, XEN D1ppp, XEN D2ppp Rated impulse withstand voltage (U imp) A V 400, degree of pollution 3, conforming to IEC 60947-1 kV Positive operation 6 Resistance across terminals 7 8 9 6, conforming to IEC 60947-1 Mushroom head pushbutton: N/C contact with positive opening operation conforming to EN/IEC 60947-5-1 Appendix K Slow break or snap action Contact operation Operating force a AC-15: A300 or Ue = 240 V, le = 3 A c DC-13: Q300 or Ue = 250 V, le = 0.27 A conforming to EN/IEC 60947-5-1 Appendix A 10 500, degree of pollution 3 With booted operator MΩ y 25 N XAC S4ppp: 10 (N/O), 8 (N/C); XEN Cpppp: 6 (N/O), 4 (N/C); XEN Bpppp, XEN D1ppp, XEN D2ppp: Single-speed: 9; 2-speed: 20 (1st speed), 30 (2nd speed); XEN D3ppp, XEN D4ppp: 25; XES B2011: 7; XES D1181, XES D128: 15 (1st speed), 25 (2nd speed) 10 With spring return mushroom N head operator With latching mushroom head N operator 40 Terminal referencing By numbers conforming to CENELEC EN 50013 Short-circuit protection 10 A cartridge fuse type gG (gl) Connection mm2 Operational power Conforming to EN/IEC 60947-5-1 Appendix C Utilisation categories AC-15 and DC-13 For 1 million operating cycles Operating rate: 3600 operating cycles/hour Load factor: 0.5 o Inductive circuit 10 References: page 6/61 6/60 Dimensions: page 6/62 Screw and captive cable clamp terminals. Clamping capacity: 1 x 2.5 or 2 x 1.5 with or without cable end Contact blocks XEN Cpppp, XEN D3ppp, XEN D4ppp, XAC S4ppp a.c. supply a 50/60 Hz d.c. supply c Voltage V 24 48 127 230 Voltage V 24 VA 140 385 525 455 W 60 o o 48 45 120 42 Contact blocks XEN Bpppp, XEN D1ppp, XEN D2ppp a.c. supply a 50/60 Hz d.c. supply c Voltage V 24 48 127 230 Voltage V VA 140 210 640 680 W o o 24 48 48 31 120 35 Contact blocks XES B2011, XES D1181, XES D1281 a.c. supply a 50/60 Hz d.c. supply c Voltage V 24 48 127 230 Voltage V VA 50 100 450 750 W o o 24 140 48 140 120 95 Application schemes: page 6/63 Presentation: page 6/64 References 6 Pendant control stations 6 Double insulated, type XAC F For control circuits Empty enclosures (XAC F: Products for maintenance purposes only) Empty enclosures (1) DF565680 Description Enclosures without cut-outs Without guard rails Protective cable sleeve Ø 10…22 mm Reference XAC F0010 Weight kg 2.100 Ø 22…35 mm XAC F0050 2.300 1 2 With guard rails Enclosures with cut-outs Without guard rails in positions requested on the order form, see page 6/65 DF565681 XAC F00p0 With guard rails Ø 10…22 mm XAC F0011 2.300 Ø 22…35 mm XAC F0051 2.500 Ø 10…22 mm XAC F3210 2.100 Ø 22…35 mm XAC F3250 2.300 Ø 10…22 mm XAC F3211 2.300 Ø 22…35 mm XAC F3251 2.500 3 4 5 6 Variable composition stations, factory assembled Use the order form on page 6/65 to define the required configuration Equipment: separate components as for control circuit pendant stations XAC B and XAC M. Units XB2 B can be mounted using a stiffening plate, please consult us. XAC F00p1 See separate components, pages 6/42 to 6/54 7 (1) Enclosure comprising: - the enclosure, - protective cable sleeve for cable Ø 10…22 mm or Ø 22…35 mm, - cable tie (for tightening sleeve onto cable, - internal cable clamp. 8 9 10 Characteristics: page 6/60 Dimensions: page 6/62 Application schemes: page 6/63 Presentation: page 6/64 6/61 Dimensions 6 Pendant control stations 6 Double insulated, type XAC F For control circuits (XAC F: Products for maintenance purposes only) Pendant control stations 1 XAC Fppp1 (30 operators maximum, front mounting) Protective cable sleeves internal Ø 10 13 13 16 16 19 19 22 2 3 (1) 619 4 40 30 internal Ø 22 26 430 26 29 29 32 32 35 5 6 150 92 7 160 137 (1) With mushroom head operator. Protective guards XAC B982 48 8 9 10 Characteristics: page 6/60 6/62 References: page 6/61 Application schemes: page 6/63 Presentation: page 6/64 Pendant control stations Application schemes (typical examples) 6 6 Double insulated, type XAC F For control circuits (XAC F: Products for maintenance purposes only) 1 33 11 – S1 13 13 14 Contact block XES D1281 11 For control of 2-speed reversing motor Contact block XES D1181 12 For control of single-speed reversing motor 12 14 34 23 43 2 44 3 A1 A2 – KM2 A2 – KM A2 – KM1 A1 A1 A2 – KM1 A2 – KM2 A1 A1 22 – S2 24 23 24 – S2 21 21 22 – S1 4 KM: high speed contactor 5 6 7 8 9 10 Characteristics: page 6/60 References: page 6/61 Dimensions: page 6/62 Presentation: page 6/64 6/63 Presentation 6 Pendant control stations Double insulated, type XAC F For control circuits (XAC F: Products for maintenance purposes only) 1 2 3 4 5 6 7 8 XAC B982 9 10 6/64 6 Pendant control stations Order form (specimen suitable for photocopying) 6 6 Double insulated, type XAC F For control circuits Variable composition stations, factory assembled (XAC F: Products for maintenance purposes only) Schneider Electric Industries Customer Company Order N° Delivery date Enter the order with XAC F09 reference Unit reference of empty enclosure with cut-outs, see page 6/61 The cut-outs indicated below only enable the mounting of contact and pilot light bodies XAC in association with operating heads/lenses ZA2 B. For other configurations, the arrangement of the cut-outs must be specifically designed. In this case, attach the configuration of the units to be mounted to this order form. XAC F Reference Order N° Number of identical stations Enclosure price (1) 1 3 Legends, see pages 6/52 to 6/54 Position of cut-outs (number or letter) Sales office - Subsidiary Co. Unit price Contact blocks or pilot light Operating heads or pilot light bodies, see pages 6/42 to 6/45 heads or blanking plug, see pages 6/46 and 6/51 Reference Unit price Reference Unit price 2 Total price 3 A 4 40 30 Ø 22,2 5 1 A 2 B 3 C 4 5 D 6 E 7 F 8 9 G 10 H 11 I 12 6 J 13 K 14 L M 15 N 16 O 17 P 18 Q 19 R 20 21 S 22 T 23 U 24 7 25 V 26 W 27 X 28 29 Y 30 8 B Unit mounted in base, if required (2) Factory assembled: Number of heads or blanking plugs to be fitted Additional cost XAC 9VA for fitting of 1 head or 1 blanking plug X Complementary accessories, see page 6/52 (cross the appropriate box or boxes) Description Reference A B Adaptor for self-supporting cable type BBAP for use with cable entry sleeve Ø 10…22 mm Protective guard for mushroom head pushbutton, mounted in base Protective guard for key release latching mushroom head pushbutton, mounted in base 9 Unit price XAC B961 XAC B983 XAC B982 10 Total price of assembled pendant station (1) Obtain the empty enclosure price with cut-outs. (2) If positions Y, 29 or 30 are used, a unit cannot be mounted in the base of the enclosure. 6/65