Square Body – Flush End Contact 1250V/1300V (IEC/U.L.) 50-1400A(-BKN/80 Type K Indicator) ® Ordering info 1 kg = 2.2 lbs. 1 lb = 0.45 kg Estimated Interrupting Rating 300kA RMS Symmetrical. Watts loss provided at rated current. Rated voltage (IEC) †1100V ‡1000V (Consult Bussmann for U.L. Recognition status.) Individual Fuse Weight: Size 1* = 0.380 kg Size 1 = 0.580 kg Size 2 = 0.900 kg Size 3 = 1.250 kg For more information please contact our agent : SOUTH CHINA ENTERPRISES (H.K.) LTD. Tel : (852)2790 1991 Fax : (852)2372 0008 Email : info@scehk.com Square Body – Flush End Contact 1250V/1300V (IEC/U.L.) 50-1400A ® Electrical Characteristics Total Clearing I2t The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, E g , (RMS). Arc Voltage This curve gives the peak arc voltage, U L , which may appear across the fuse during its operation as a function of the applied working voltage, E g , (RMS) at a power factor of 15%. Power Losses Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, K p , is given as a function of the RMS load current, Ib , in % of the rated current . 1.5 K 1.25 1.0 3 2.5 1.0 Kp 0.8 UL 0.6 0.5 1.8 1.4 0.4 0.5 0.4 103 8 0.3 0.3 6 5 0.2 0.2 4 Eg 400 600 800 Eg 3 400 1000 1200 1400 600 800 Ib 0.1 30 40 50 1000 1200 1400 60 70 80 90 100% -----Dashed lines apply to the following amperages: Size Amp 1* 400 1 500-630 2 630-1000 3 800-1400 Dimensions Flush End Contact: Type -BKN/-, -GKN/- B D A E F E H G Size 1* 1* 1 1 2 2 2 3 3 3 Type BKN + GKN/75 BKN/80 BKN + GKN/75 BKN/80 BKN + GKN/75 BKN/80 BKN + GKN/90 BKN + GKN/75 BKN/80 BKN + GKN/90 A 74 80 74 80 74 80 80 74 81 81 B 75 81 75 81 75 81 91 76 83 91 D 59 59 69 69 77 77 77 92 92 92 E 45 45 53 53 61 61 61 76 76 76 F M8 M8 M8 M8 M10 M10 M10 M12 M12 M12 F§ fiΩ¡§∑ - 18 UNC-2B fiΩ¡§∑ - 18 UNC-2B ‹Ω•∑ - 16 UNC-2B ‹Ω•∑ - 16 UNC-2B ⁄Ω™∑ - 13 UNC-2B ⁄Ω™∑ - 13 UNC-2B G 5 5 8 8 10 10 10 10 10 10 H Ø17 Ø17 Ø20 Ø20 Ø24 Ø24 Ø24 Ø30 Ø30 Ø30 § Valid for fuses type -GK/Dimension in mm. 1mm = 0.0394∑ 1∑ = 25.4mm For more information please contact our agent : SOUTH CHINA ENTERPRISES (H.K.) LTD. Tel : (852)2790 1991 Fax : (852)2372 0008 Email : info@scehk.com Square Body – Flush End Contact 1250V/1300V (IEC/U.L.) 50-1400A ® Size 1: 1250V (160-630)A Time-Current Curve 160A 200A 250A 315A 350A 400A 450A 500A 550A 630A Size 1*: 1250V (50-400)A Time-Current Curve 104 103 102 Virtual Pre-Arcing Time In Seconds A A 101 100 10–1 10–2 10–3 1x10–4 Peak Let-Through Curve 10 1x102 105 B 400A 350A 315A 250A 200A 160A 125A 100A 80A 63A 50A 104 Peak Let-Through In Amperes Peak Let-Through Current 105 Peak Let-Through Curve 5 B 630A 550A 500A 450A 400A 350A 315A 250A 200A 160A 104 103 103 A A 2x10 103 104 Prospective Current In Amperes RMS 2x102 2 1x102 103 104 105 Prospective Short-Circuit Current Symmetrical RMS 106 1x102 103 104 105 Prospective Short-Circuit Current Symmetrical RMS 106 630 amp fuse is derated to 1100V (IEC). For more information please contact our agent : SOUTH CHINA ENTERPRISES (H.K.) LTD. Tel : (852)2790 1991 Fax : (852)2372 0008 Email : info@scehk.com Square Body – Flush End Contact 1250V/1300V (IEC/U.L.) 50-1400A ® Size 3: 1250V (315-1400)A Time-Current Curve Time-Current Curve 250A 280A 315A 350A 400A 450A 500A 550A 630A 700A 800A 900A 1000A Size 2: 1250V (250-1000)A 104 103 102 Virtual Pre-Arcing Time In Seconds A A 101 100 10–1 10–2 10–3 1x10–4 1x102 103 104 Prospective Current In Amperes RMS 105 Peak Let-Through Curve Peak Let-Through Curve 105 1000A 900A 800A 700A 630A 550A 500A 450A 400A 315A 350A 280A 250A 104 103 B 1250A 1100A 1000A 900A 800A 700A 630A 550A 500A 450A 400A 350A 315A 104 103 A 2x10 1400A 105 Peak Let-Through Current Peak Let-Through Current B A 2 1x10 2 3 4 10 10 10 Prospective Short-Circuit Current Symmetrical RMS 5 900-1000 amp fuses are derated to 1100V (IEC). 6 10 2x10 2 1x102 103 104 105 Prospective Short-Circuit Current Symmetrical RMS 106 1250-1400 amp fuses are derated to 1100V (IEC). For more information please contact our agent : SOUTH CHINA ENTERPRISES (H.K.) LTD. Tel : (852)2790 1991 Fax : (852)2372 0008 Email : info@scehk.com