EASY OPERATION MODERN DESIGN WITH EASY TO USE The Interlock 7000 consists of two components: a handset and control unit. In the handset the breath sample is analysed. The control unit releases or blocks the starter relay of the vehicle. Once the vehicle’s ignition is switched on, the Dräger Interlock® 7000 requests a breath sample from the driver. If the device detects an alcohol value above the set limit, it prevents the engine from being started. The device helps to systematically eliminate alcohol-related risks of accidents and to stop drink driving. FUNCTIONALITY The design of the Dräger Interlock® 7000 is appealing and ergonomic, with the mouthpiece on the back of the handset – hence, not easily recognised as an alcohol ignition interlock device. The newly designed hygienic mouthpieces are completely biodegradable. The navigation on the colour display makes the use of this device easy and intuitive. Additionally, coloured LEDs on the device enhance the ease of use for the user. D-98730-2013 The Dräger Interlock® 7000 is an alcohol ignition interlock device which prevents a person under the influence of alcohol from starting the vehicle. The Dräger Interlock® 7000 has a quick start-up time. Additionally, the device can be equipped with a camera and/or a GPRS module, according to the specific customer requirements. D-6683-2014 Dräger Interlock® 7000 Interlock® 7000 handset The data log of the Dräger Interlock® 7000 saves all relevant events such as date, time, submission or refusal to submit a breath sample, measured alcohol concentration, engine starts and stops and any attempts to tamper with the device. The data is transferred from the control unit to the PC via an infrared interface or via Bluetooth. Downloaded data is available to authorised persons only. From creation of the image, to provision of the data, special encryption methods guarantee data protection. Interlock® 7000 camera D-90542-2013 The extremely quick start-up time is one of the many new features of the Dräger Interlock® 7000. At temperatures above 0 °C, the Dräger Interlock® 7000 is ready for immediate use. With an approved temperature range of - 45 °C to 85 °C, it ensures that the device works reliably under all kinds of ambient conditions. D-98751-2013 SAFE DATA HANDLING QUICK START-UP TIME AND RELIABILITY Interlock® 7000 GPRS module 02 02 | | ® 7000 DRÄGER INTERLOCK KAPITEL | UNTERKAPITEL GPRS MODULE CAMERA RELIABLE MEASUREMENT TECHNOLOGY If the Dräger Interlock® 7000 is equipped with an additional GPRS module, it is possible for certain predefined events to transmit data automatically to the responsible entity or person via the GPRS module. This event can, for example, be an attempt to start the engine under the influence of alcohol. The camera is fully integrated into the Dräger Interlock® 7000 and records the submitted breath samples with images. If necessary, it can be easily installed in each vehicle. The infrared technology ensures good image quality, regardless of whether it is day or night. The Dräger Interlock® 7000 specifically measures alcohol. The measuring result is reliable and precise. Any attempts to bypass or manipulate the device are automatically identified and stored in the data log. The device is able to identify whether the alcohol detected in the breath sample is actual breath alcohol or only mouth alcohol. Coloured LEDs Control unit Installed under the dashboard; logs all events Connector for GPRS module Mouthpiece Easy to replace; on the back of the handset Connector for handset D-98940-2013 Colour display User guidance with text messages Handset (measuring device) Located in the interior of the vehicle Cables Connections to the vehicle electrical system Connector for camera 2.Request to provide a breath sample 3. Measurement of breath alcohol concentration D-6674-2014 D-85336-2013 D-85327-2013 D-6653-2014 1. Switch on ignition D-85339-2013 HOW IT WORKS 4. Breath sample accepted: Starter is released 5. Start the engine DRÄGER INTERLOCK® 7000 With more than 60 years of experience, Dräger is world market leader in breath alcohol measurement. The Alcotest® product family is used by police authorities in many countries for traffic control. The Dräger Interlock® 7000 uses the proven sensor technology of the Alcotest®. Alcohol ignition interlocks by Dräger have successfully been established for more than two decades. D-6665-2014 PROVEN DRÄGER TECHNOLOGY Ready for testing TECHNICAL DATA Measuring principle Ambient conditions for operation Readiness for use Display Calibration interval Data logger Dimensions (H × W × D) Weight Power supply Switch relay for the starter relay line Power consumption Approvals Data transfer Electrochemical sensor Temperature - 45 °C to 85 °C < 4 sec. (above 0 °C) < 60 sec. (at - 20 °C) < 110 sec. (at - 45 °C) Graphic colour display in handset with full text messages typically 6 – 12 months in the control unit, for up to 500.000 events Handset approx. 138 mm × 61 mm × 36 mm Control unit approx. 148 mm × 90 mm × 32 mm Handset approx. 178 g Control unit approx. 300 g 12 V to 24 V < 16 A continuous, < 40 A peak, output relay may switch up to 48 V < 2 A maximum, < 1 mA stand-by General German Operating Permission (Allgemeine Betriebserlaubnis Deutschland); EN 50436-1:2013, EN 50436-2:2013, E1 mark, ECE Regulation No. 10, and Directive (EC) No. 661/2009 (with last applicable amendment), AS 3547 – 1997 Infrared interface, Bluetooth ORDERING INFORMATION Dräger Interlock® 7000 Breath alcohol-controlled vehicle immobiliser (handset and control unit) for installation in motor vehicles, mouthpieces (3 pieces), holder, and mounting accessories Dräger Interlock® 7000 GPRS module Dräger Interlock® 7000 camera Mouthpieces (5 pieces), individually packed Mouthpieces (300 pieces), individually packed 83 22 570 83 22 534 83 22 413 83 22 446 83 22 597 | 03 90 45 510 | 09.14-1 | Communications & Sales Marketing | PP | LE | Printed in Germany | Chlorine-free – environmentally compatible | Subject to modifications | © 2014 Drägerwerk AG & Co. KGaA CORPORATE HEADQUARTERS Drägerwerk AG & Co. KGaA Moislinger Allee 53–55 23558 Lübeck, Germany SALES AND SERVICE CENTRES AUSTRALIA www.draeger.com MELBOURNE DARWIN Draeger Safety Pacific Pty. Ltd. 8 Acacia Place Notting Hill VIC 3168 Toll-free +61 1800 DRAGER (1800 372 437) Fax+61 1800 64 74 84 customer.service@draeger.com Unit 1, 408 Stuart Highway Winnellie NT 0820 PERTH 72A Irvine Drive Malaga WA 6090 SYDNEY ADELAIDE 258 Grange Road Flinders Park SA 5025 Unit 15, 38-46 South Street Rydalmere NSW 2116 NEW ZEALAND BRISBANE Manufacturer: Dräger Safety AG & Co. KGaA Revalstraße 1 23560 Lübeck, Germany Unit 7, Rocklea Place 1909 Ipswich Road Rocklea QLD 4106 Draeger Safety Pacific Pty. Ltd. Unit 4, 24 Bishop Dunn Place East Tamaki, Auckland 2013 Tel 0800 372 437 Fax0800 733 133 Please visit www.draeger.com/interlock for a full list of Dräger authorised Service Centres in Australia and New Zealand.