Folder 800_e - ECO PHYSICS AG

advertisement
CLD 800 Series
We measure
what’s in the air.
Measurably better.
Our analyzers detect nitrogen oxides
at any level.
No matter where and at what concentrations nitrogen oxides
have to be detected, you can depend on ECO PHYSICS analyzers to handle the job quickly, reliably and with a precision that
is unmatched anywhere in the world. Whether at trace levels
in a clean room environment or for the analysis of exhaust
gases directly at the source, you will find the type of chemiluminescence detector (CLD) to perfectly suit you at ECO PHYSICS.
Range of Applications
Converters
MEDICAL & ENVIROMENTAL RESEARCH
CLD 88
C
PROCESS CONTROL
DENOX PLANTS
CLD 844 CM
Y
PHARMA/BIOTECH
GENERATORS/
TURBINES
CHEMICAL PLANTS
M
CLD 88 CY
MONITORING
STATIONS
CLD 88 Y
CLD 86 Y
CLD 84 M
CLD 822 M
GAS MANUFACTURERS
POWER STATIONS
CLD 822 S
S
HEAVY INDUSTRY
CLD 82 S
Sensitivity
5000 ppm
CLD 844 M
EXHAUST GAS
CLD 84 S
500 ppm
50 ppm
5 ppm
Our analyzers come Improving the air quality starts with a solution. For the surveillance of indusinto action wherever reduction of nitric oxides. Accordingly, trial processes as well as for the sciennitrogen oxides have the authorities are constantly lowering tist in atmospheric research.
to be measured. the limits of permitted pollution. The
monitoring of compliance with set
CLD means high reliability.
limits of pollution requires ever more The principle of chemiluminescence
sophisticated measuring equipment. detection is an extremely selective
ECO PHYSICS CLD NOX analyzers are method for measuring nitrogen oxides
the best choice for obtaining precise precisely, with high linearity over a
and reliable values for the presence of wide concentration range and with
NO, NO2, NOX, NH3 or NOX amines very high reproducibility. These qualiin the sample gas. Whether in opera- ties are the basis for the acknowledged
tion as stand-alone units or integrated high performance of ECO PHYSICS
into measuring systems, with or without CLD NOX analyzers in tracing nitrogen
external sample gas preparation, we oxides even down to the low ppt level.
can always offer the most appropriate
Basic Analyzer
Compact design with minimal
Cover plate guided
Hidden connections
space requirement
in slots
Radial ventilation, ideal for
Excellent display
All functions can
rack and laboratory use
legibility thanks to
be operated
angled front panel
via the keypad
The unique concept.
Simply user friendly.
Concerning precision, dynamic range Ease of operation for our CLD NOX anand response times, ECO PHYSICS alyzers has always been our special
CLD NOX analyzers are setting global concern. The clear menu structure enstandards and the convincing concept ables the user to take advantage of all
of modularity is unique. Start with a the features and functions of the analyzer and control
All analyzers can be
it either via the
supplied with pull-out
keypad
rails, perfect for rack
at
the
front panel or via
mounting
a
PC.
Mainte-
nance-free components for ozone
production
and
single channel CLD 8x NO analyzer as destruction, the oil-free vacuum pump The external connections
a basis. Add modules such as an NO2 and filters result in a minimum of main- are recessed and easily
or NOX amine converter, an addition- tenance costs even in permanent oper- accessible, eliminating the
al reaction chamber, a heated sample ation.
need for extra depth
inlet or even a calibration gas divider
to configure the optimal NOX analyzer
The ECO PHYSICS quality assurance.
for your specific application. For Each and every CLD NOX analyzer
measuring the nitrogen oxides from must pass an extensive test procedure
two different sample sources, simply before it leaves the factory. Test proceadd a second sample inlet and save dures and test equipment comply with
cost. And remember: there is room
for all these components including the powerful vacuum
pump (membrane type) and
ISO 9001 standards and are documented in accordance
with international
regulations.
the thermal ozone scrubber in one case.
All in one: All components
are clearly laid out in a
single case
© ECO PHYSICS, 2016–5/6
printed climate neutrally
Creativity, curiosity and
dedication to quality.
We are reaching for new markets and solutions guided by creativity and nourrished by curiosity in our customer’s needs.
ECO PHYSICS offers today the fastest and most sensitive analyzers based on the principle of chemiluminescence.
Clean air is quality of life.
inventing this statement daily. Discov-
Since many years and throughout the ering emerging applications from your
globe, ECO PHYSICS is known. Our new requirements is our challenge to
instruments are in place to accurately develop solutions. Creativity, curiosity
measure nitrogen oxides: to check and the dedication to quality have
stack and exhaust gases, to observe brought us an excellent reputation and
air quality regulations, to improve led you closer to your goals.
health. Many scientists of the most reputed institutes and research centers
Swiss quality, certified.
rely on the quality of their measure- First grade quality is a condiments with ECO PHYSICS analyzers.
tion, although it has been
derived from international stan-
Focus on customer requirements.
dards. It has been independantly
Reg. No.
0421.57.01/0
EN ISO 9001:2008
EN ISO 13485:2007
Working with customers that are at the certified for ECO PHYSICS. Each and
leading edge of analytical and process every product leaving our factory un-
- CPS
m
technology, we strive to anticipate the dergoes a strict quality control procechanging needs of all our clients. Our dure. These performance tests can be
market specialists for the business seg- recalled for every analyzer, that ever
left our manufacturing plant.
ments
• environment
• industrial processes
Partnership with you.
• automotive and combustion engines
Initiate a contact and we will add our
• manufacturing of semiconductors
part – this means partnership to us. In
• medical diagnostics
close co-operation with you we are de-
and our world wide representatives veloping solutions which comply with
your
maintain contact with you.
specific
requirements.
ECO
PHYSICS and our representatives are
The pace of our R&D-team.
there when you need us – at the start of
The limits of technology are relative. your project, through to the whole live,
Our motivated people in R&D are support and service.
ECO PHYSICS AG · BUBIKONERSTRASSE 45 · CH - 8635 DUERNTEN · TEL. +41 55 220 22 22 · FAX +41 55 220 22 55 · INFO@ECOPHYSICS.COM
INTERNET WWW.ECOPHYSICS.COM
Download