CLD 800 Series We measure what’s in the air. Measurably better. Our analyzers detect nitrogen oxides at any level. No matter where and at what concentrations nitrogen oxides have to be detected, you can depend on ECO PHYSICS analyzers to handle the job quickly, reliably and with a precision that is unmatched anywhere in the world. Whether at trace levels in a clean room environment or for the analysis of exhaust gases directly at the source, you will find the type of chemiluminescence detector (CLD) to perfectly suit you at ECO PHYSICS. Range of Applications Converters MEDICAL & ENVIROMENTAL RESEARCH CLD 88 C PROCESS CONTROL DENOX PLANTS CLD 844 CM Y PHARMA/BIOTECH GENERATORS/ TURBINES CHEMICAL PLANTS M CLD 88 CY MONITORING STATIONS CLD 88 Y CLD 86 Y CLD 84 M CLD 822 M GAS MANUFACTURERS POWER STATIONS CLD 822 S S HEAVY INDUSTRY CLD 82 S Sensitivity 5000 ppm CLD 844 M EXHAUST GAS CLD 84 S 500 ppm 50 ppm 5 ppm Our analyzers come Improving the air quality starts with a solution. For the surveillance of indusinto action wherever reduction of nitric oxides. Accordingly, trial processes as well as for the sciennitrogen oxides have the authorities are constantly lowering tist in atmospheric research. to be measured. the limits of permitted pollution. The monitoring of compliance with set CLD means high reliability. limits of pollution requires ever more The principle of chemiluminescence sophisticated measuring equipment. detection is an extremely selective ECO PHYSICS CLD NOX analyzers are method for measuring nitrogen oxides the best choice for obtaining precise precisely, with high linearity over a and reliable values for the presence of wide concentration range and with NO, NO2, NOX, NH3 or NOX amines very high reproducibility. These qualiin the sample gas. Whether in opera- ties are the basis for the acknowledged tion as stand-alone units or integrated high performance of ECO PHYSICS into measuring systems, with or without CLD NOX analyzers in tracing nitrogen external sample gas preparation, we oxides even down to the low ppt level. can always offer the most appropriate Basic Analyzer Compact design with minimal Cover plate guided Hidden connections space requirement in slots Radial ventilation, ideal for Excellent display All functions can rack and laboratory use legibility thanks to be operated angled front panel via the keypad The unique concept. Simply user friendly. Concerning precision, dynamic range Ease of operation for our CLD NOX anand response times, ECO PHYSICS alyzers has always been our special CLD NOX analyzers are setting global concern. The clear menu structure enstandards and the convincing concept ables the user to take advantage of all of modularity is unique. Start with a the features and functions of the analyzer and control All analyzers can be it either via the supplied with pull-out keypad rails, perfect for rack at the front panel or via mounting a PC. Mainte- nance-free components for ozone production and single channel CLD 8x NO analyzer as destruction, the oil-free vacuum pump The external connections a basis. Add modules such as an NO2 and filters result in a minimum of main- are recessed and easily or NOX amine converter, an addition- tenance costs even in permanent oper- accessible, eliminating the al reaction chamber, a heated sample ation. need for extra depth inlet or even a calibration gas divider to configure the optimal NOX analyzer The ECO PHYSICS quality assurance. for your specific application. For Each and every CLD NOX analyzer measuring the nitrogen oxides from must pass an extensive test procedure two different sample sources, simply before it leaves the factory. Test proceadd a second sample inlet and save dures and test equipment comply with cost. And remember: there is room for all these components including the powerful vacuum pump (membrane type) and ISO 9001 standards and are documented in accordance with international regulations. the thermal ozone scrubber in one case. All in one: All components are clearly laid out in a single case © ECO PHYSICS, 2016–5/6 printed climate neutrally Creativity, curiosity and dedication to quality. We are reaching for new markets and solutions guided by creativity and nourrished by curiosity in our customer’s needs. ECO PHYSICS offers today the fastest and most sensitive analyzers based on the principle of chemiluminescence. Clean air is quality of life. inventing this statement daily. Discov- Since many years and throughout the ering emerging applications from your globe, ECO PHYSICS is known. Our new requirements is our challenge to instruments are in place to accurately develop solutions. Creativity, curiosity measure nitrogen oxides: to check and the dedication to quality have stack and exhaust gases, to observe brought us an excellent reputation and air quality regulations, to improve led you closer to your goals. health. Many scientists of the most reputed institutes and research centers Swiss quality, certified. rely on the quality of their measure- First grade quality is a condiments with ECO PHYSICS analyzers. tion, although it has been derived from international stan- Focus on customer requirements. dards. It has been independantly Reg. No. 0421.57.01/0 EN ISO 9001:2008 EN ISO 13485:2007 Working with customers that are at the certified for ECO PHYSICS. Each and leading edge of analytical and process every product leaving our factory un- - CPS m technology, we strive to anticipate the dergoes a strict quality control procechanging needs of all our clients. Our dure. These performance tests can be market specialists for the business seg- recalled for every analyzer, that ever left our manufacturing plant. ments • environment • industrial processes Partnership with you. • automotive and combustion engines Initiate a contact and we will add our • manufacturing of semiconductors part – this means partnership to us. In • medical diagnostics close co-operation with you we are de- and our world wide representatives veloping solutions which comply with your maintain contact with you. specific requirements. ECO PHYSICS and our representatives are The pace of our R&D-team. there when you need us – at the start of The limits of technology are relative. your project, through to the whole live, Our motivated people in R&D are support and service. ECO PHYSICS AG · BUBIKONERSTRASSE 45 · CH - 8635 DUERNTEN · TEL. +41 55 220 22 22 · FAX +41 55 220 22 55 · INFO@ECOPHYSICS.COM INTERNET WWW.ECOPHYSICS.COM