Features: Lightning performance improvement of transmission lines Reduction of double and multicircuit outages Switching overvoltage control Overvoltage control in the vicinity of high voltage substations Prevention of risk to people and animals Open breaker protection Line design without shield wire: Loss reduction Compact line design Line voltage uprating US 138 kV line Advantages of the polymer housed surge arresters: Sediver has more than 30 years experience in composite insulator technology in direct injection molding of the polymer housing under high pressure and high temperature. This technology is applied to our surge arresters out of which we obtain: Increased life time of the ZnO blocks which are protected from moisture ingress thanks to our impenetrable design Excellent mechanical characteristics due to the fiber glass reinforced polymer tube Excellent pollution performance of the silicone housing Excellent protection performance due to very stringent selection of extra high quality, high energy duty metal oxide blocks Increased safety of surrounding crew and equipment thanks to the explosion proof design (air-free) Easy to install and transport due to the low weight Reduced space requirements thanks to its compact design Norway 300 kV line Selection: Through expertise conducted using simulation software tools, our experts are able to determine optimal arresters types & location to protect the key points of the system, thus providing effective protection at the lowest cost. Contact Sediver representative Installation: • Directly on the insulator string • On transmission towers • Suspended under phase conductor • Customized installation configuration according to your specific requirements is also possible Sediver composite gapless line surge arresters Sediver surge arresters offer unique features for enhanced performance of your High Voltage system. technical file 2008 Sediver composite gapless line surge arresters Product range (*) System voltage SLA.1 44-170 (kV) Arrester class [IEC 60099.4] SLA.2 44-245 1 SLA.3 44-400 2 3 Nominal discharge current (kA) 10 10 10 High amplitude current withstand [4/10 ms] (kA) 100 100 100 Maximum long duration current impulse (A) 250 500 800 Maximum short circuit rating (kA) 40 63 63 Maximum permissible bending moment (Nm) 700 1350 2500 SLA.1 - Class 1 surge arresters (**) 8/20 μs residual voltage (kV crest) Ur MCOV TOV (1s) SSPL SIPL kV rms kV rms kV kV crest kV crest 5 kA crest 10 kA crest 20 kA crest 60 48 70 138 185 161 176 194 72 58 84 166 222 194 211 233 96 77 112 221 296 258 281 310 108 86 126 249 333 290 316 349 120 96 140 276 370 323 351 388 144 115 168 332 444 387 422 465 SLA.2 - Class 2 surge arresters (**) Ur MCOV TOV (1s) SSPL SIPL 8/20 μs residual voltage (kV crest) kV rms kV rms kV kV crest kV crest 5 kA crest 10 kA crest 20 kA crest 60 48 70 128 171 150 162 178 72 58 84 154 205 180 194 214 96 77 112 205 273 240 259 285 108 86 126 231 307 270 291 321 120 96 140 257 341 300 324 356 144 115 168 308 409 360 388 427 192 154 224 411 546 480 518 570 SLA.3 - Class 3 surge arresters (**) Ur: MCOV: SSPL: SIPL: Ur MCOV TOV (1s) SSPL SIPL 8/20 μs residual voltage (kV crest) kV rms kV rms kV kV crest kV crest 5 kA crest 10 kA crest 20 kA crest 72 58 84 148 190 168 180 199 96 77 112 198 253 223 240 265 108 86 126 222 285 252 270 298 120 96 140 247 316 280 300 331 144 115 168 296 379 336 360 397 192 154 224 395 506 447 480 530 228 182 266 469 601 531 570 629 252 202 294 518 664 587 630 696 336 269 392 691 885 783 840 927 360 288 420 741 949 839 900 994 Rated voltages Maximum Continuous Operating Voltage Switching Surge Protective Level (30/60 μs wave; 250 Acrest for Class 1; 500 Acrest for Class 2; 1000 Acrest for Class 3) Steep Impulse Protective Level (1/20 μs wave; 10 kA crest) Seves Canada Inc. Seves USA Inc. 172 Merizzi, Ville St-Laurent, Quebec, Canada H4T 1S4 T +1 514 739 3385 - F +1.514.739.3669 info@seves.ca - www.sevespower.com 6605 Cypresswood Drive, suite #450, Houston, Texas 77379 T +1 281 257 8222 - F +1 281 257 8225 info@sevesusa.com - www.sevespower.com (*) Subject to change without prior notice < Continuous product improvement (**) Frequently used arresters - all rated voltages according to IEC 60099 and ANSI/IEEE C62.11 available Sediver © Doc.S.D.L/S.S/C.L/P.S -C04-V2011_US Sediver composite gapless line surge arresters Protective characteristics (*)