NYC Department of Education
Building Condition Assessment Survey 2014-2015
Electrical Inspection
M807
HARVEY MILK SCHOOL - MANHATTAN, 2-10 ASTOR PLACE, MANHATTAN, NY, 10003
School:
InspectionId
Inspection Type
11103 ELECTRICAL
Time In
Last Edited
2015-01-15 12:36PM
2015-01-30 12:51PM
Asset Data
Question
Answer
Have any Systems/Major Building Components been upgraded?
Systems:
All Systems And Components
Years:
2003
Below Ground
Type of Service
Does Interactive Whiteboard (IWB) Exist?
Yes
DEDICATED INTERCOMS IN FIRE RESCUE AREAS
Question
Are there any Life Rescue Assistance Areas, Fire Rescue Areas, and/or Holding Rooms
in your building?
Response
No
Priority Condition
Priority Condition
Exist Last Year?
Priority
Category
Condition
Description
Component
Affected
Location
Description
Person(s) Notified
Person(s) Title
PhotoImage
No condition recorded
Inspection
Question
Response
Electrical
ATHLETIC FIELD
Does not exist
AUDITORIUM
Does not exist
AUXILIARY SIGNAL/BELL SYSTEM
Does not exist
CAFETERIA
Instance on 3rd Floor
Inspected
Instance on 3rd Floor
Inspected
Lighting
Lighting Fixture - Fluorescent
Inspected
Instance on 3rd Floor
Pendant Mounted
Instance on 3rd Floor
Inspected
Instance Condition
2- Between Good and Fair
Deficiency
No deficiencies recorded
Recessed Mounted
Does not exist
Instance on 3rd Floor
Surface Mounted
Does not exist
Instance on 3rd Floor
Lighting Fixture - HID
Does not exist
Instance on 3rd Floor
Lighting Fixture - Incandescent
Inspected
Instance on 3rd Floor
Pendant Mounted
Does not exist
Instance on 3rd Floor
Recessed Mounted
Does not exist
Instance on 3rd Floor
Surface Mounted
Instance on 3rd Floor
Inspected
Instance Condition
2- Between Good and Fair
Deficiency
No deficiencies recorded
Lighting Fixture - LED
Does not exist
Instance on 3rd Floor
Local Sound System
Does not exist
Instance on 3rd Floor
Projection System
Mobile Validity Version 2.0 (P)
Page 1 of 7
Print Date: 6/18/2015
NYC Department of Education
Building Condition Assessment Survey 2014-2015
Electrical Inspection
M807
Question
Response
CAFETERIA
Projection System
Instance on 3rd Floor
Does not exist
Theater Lighting System
Does not exist
Instance on 3rd Floor
CITY FIRE ALARM SYSTEM
Does not exist
CLASSROOM/CORRIDOR/ADMINISTRATIVE SPACE
Inspected
Inspected
Lighting
Does a Chandelier Exist?
No
Inspected
Lighting Fixture - Fluorescent
Inspected
Pendant Mounted
2- Between Good and Fair
Condition
Deficiency
No deficiencies recorded
Inspected
Recessed Mounted
2- Between Good and Fair
Condition
Deficiency
No deficiencies recorded
Inspected
Surface Mounted
2- Between Good and Fair
Condition
Deficiency
No deficiencies recorded
Lighting Fixture - HID
Does not exist
Lighting Fixture - Incandescent
Does not exist
Lighting Fixture - LED
Does not exist
COMPUTER LAB
Does not exist
EMERGENCY DC STANDBY BATTERY POWER
Does not exist
EMERGENCY GENERATOR SET
Does not exist
EMERGENCY LIGHT/EXIT LIGHT PANEL
Does not exist
EMERGENCY LIGHTING
Inspected
Inspected
Battery Pack
3- Fair
Condition
Deficiency
No deficiencies recorded
Does not exist
Non Battery Pack
Inspected
EXIT LIGHT
Inspected
Battery Pack
3- Fair
Condition
Deficiency
No deficiencies recorded
Does not exist
Non Battery Pack
Inspected
EXIT/EMERGENCY LIGHT
3- Fair
Condition
Deficiency
No deficiencies recorded
FIRE ALARM SYSTEM
Inspected
Area Smoke Detector
Inspected
2- Between Good and Fair
Condition
Deficiency
No deficiencies recorded
Inspected
Bell/Horn
2- Between Good and Fair
Condition
Deficiency
No deficiencies recorded
Inspected
Duct Smoke Detector
2- Between Good and Fair
Condition
Deficiency
No deficiencies recorded
Inspected
Elevator Recall
2- Between Good and Fair
Condition
Deficiency
No deficiencies recorded
Inspected
Fan Shutdown Control
2- Between Good and Fair
Condition
Mobile Validity Version 2.0 (P)
Page 2 of 7
Print Date: 6/18/2015
NYC Department of Education
Building Condition Assessment Survey 2014-2015
Electrical Inspection
M807
Question
Response
FIRE ALARM SYSTEM
Fan Shutdown Control
Deficiency
No deficiencies recorded
Fire Alarm Digital Communicator
Does not exist
Fused Cutout Panel
Inspected
2- Between Good and Fair
Condition
Deficiency
No deficiencies recorded
Heat Detector
Does not exist
Magnetic Door Holder/Contactor
Does not exist
Main Panel
Inspected
Inspected
Bell At Panel
Condition
2- Between Good and Fair
Deficiency
No deficiencies recorded
Inspected
Fire Alarm Control Panel (Electronic)
Instance
3rd Floor - Reception Area Next To Elevator
2- Between Good and Fair
Instance Condition
Instance Quantity
1
EACH
Instance Quantity Uom
Edwards System Technology
EST 3
N/A
12
Zones
1
Section(s)
Inspector Estimate
2003
Documented
Manufacturer
Model
EquipmentId
Capacity/Size Quantity
Capacity/Size UOM
Capacity/Size 2 Quantity
Capacity/Size 2 UOM
Source of Capacity/Size
Installation Year
Source of Installation Year
Deficiency
Deficiency Quantity
PANEL ID IS MISSING
1
EACH
MAINTENANCE
PRIORITY 2
LEVEL 2
No violations recorded
Quantity Uom
Potential Action
Urgency of Action
Purpose of Action
Violations
Does not exist
Fire Alarm Control Panel (Standard)
Inspected
Manual Pull Station
2- Between Good and Fair
Condition
Deficiency
No deficiencies recorded
Remote Annunciator
Does not exist
Sprinkler Flow/Air Pressure Switch
Inspected
2- Between Good and Fair
Condition
Deficiency
No deficiencies recorded
Inspected
Strobe
2- Between Good and Fair
Condition
Deficiency
No deficiencies recorded
Sub-Panel
Does not exist
Tamper Flow Switch/Chain
Inspected
2- Between Good and Fair
Condition
Deficiency
No deficiencies recorded
GROUNDING SYSTEM
Does not exist
GYMNASIUM
Does not exist
INTERCOM SYSTEM
Inspected
Inspected
Elevator
3- Fair
Condition
Mobile Validity Version 2.0 (P)
Page 3 of 7
Print Date: 6/18/2015
NYC Department of Education
Building Condition Assessment Survey 2014-2015
Electrical Inspection
M807
Question
Response
INTERCOM SYSTEM
Elevator
Deficiency
No deficiencies recorded
Does not exist
Holding Area
KITCHEN/WARMING PANTRY
Instance on 3rd Floor
Inspected
Instance on 3rd Floor
Inspected
Lighting
Lighting Fixture - Fluorescent
Inspected
Instance on 3rd Floor
Pendant Mounted
Instance on 3rd Floor
Inspected
Instance Condition
2- Between Good and Fair
Deficiency
No deficiencies recorded
Recessed Mounted
Instance on 3rd Floor
Inspected
Instance Condition
2- Between Good and Fair
Deficiency
No deficiencies recorded
Surface Mounted
Does not exist
Instance on 3rd Floor
Lighting Fixture - HID
Does not exist
Instance on 3rd Floor
Lighting Fixture - Incandescent
Does not exist
Instance on 3rd Floor
Lighting Fixture - LED
Does not exist
Instance on 3rd Floor
Inspected
LAN
Local Distribution Frame (I/LDF)
Does not exist
Main Equipment Rack (MDF)
Inspected
3- Fair
Condition
Deficiency
No deficiencies recorded
LIBRARY
Does not exist
LIGHTNING PROTECTION
Does not exist
LOCKER ROOM
Does not exist
MOTOR CONTROL CENTER
Does not exist
MOTOR STARTER/CONTACTOR
Does not exist
MULTIPURPOSE ROOM
Does not exist
PANEL BOARD
Inspected
Fused Disconnect Switch Type
Does not exist
Fused Knife Switch Type
Does not exist
Fused Toggle Switch Type
Does not exist
Molded Case Circuit Breaker Type
Inspected
2- Between Good and Fair
Condition
Deficiency
No deficiencies recorded
Inspected
PUBLIC ADDRESS SYSTEM
Instance
Room 314 - Server Room
2- Between Good and Fair
Instance Condition
Instance Quantity
1
EACH
Instance Quantity Uom
Model
Installation Year
Source of Installation Year
Rauland MPA 250
2003
Documented
Deficiency
No deficiencies recorded
Does not exist
SCIENCE DEMO ROOM
Mobile Validity Version 2.0 (P)
Page 4 of 7
Print Date: 6/18/2015
NYC Department of Education
Building Condition Assessment Survey 2014-2015
Electrical Inspection
M807
Question
Response
SCIENCE LAB
Does not exist
SCIENCE PREP ROOM
Does not exist
SECURITY
Inspected
Inspected
Intrusion Alarm System
Central Control Panel
Does not exist
Infrared Sensor
Inspected
Condition
2- Between Good and Fair
Deficiency
No deficiencies recorded
Panic Switch
Does not exist
Remote Annunciator
Inspected
Condition
2- Between Good and Fair
Deficiency
No deficiencies recorded
Inspected
Siren/Strobe
Condition
2- Between Good and Fair
Deficiency
No deficiencies recorded
Does not exist
Ultrasonic Sensor
Inspected
IPDVS/CCTV System
2- Between Good and Fair
Condition
Installation Year
Source of Installation Year
2003
Documented
Deficiency
No deficiencies recorded
Does not exist
Lighting - Security
Inspected
SERVICE SWITCH
Instance
3rd Floor - Closet In Reception Area
2- Between Good and Fair
Instance Condition
Instance Quantity
Instance Quantity Uom
1
EACH
Manufacturer
EquipmentId
Capacity/Size Quantity
Capacity/Size UOM
Source of Capacity/Size
Installation Year
Source of Installation Year
General Electric
N/A
400
Amps
Nameplate
2003
Documented
Deficiency
Deficiency Quantity
SWITCH ID IS MISSING
1
EACH
MAINTENANCE
PRIORITY 2
LEVEL 2
No violations recorded
Quantity Uom
Potential Action
Urgency of Action
Purpose of Action
Violations
SWIMMING POOL
Does not exist
SWITCHBOARD
Water Penetration In Electrical Room?
Number of Spares
Inspected
Air Circuit Breaker Type
No
0
Does not exist
Fused Disconnect Switch Type
Does not exist
Fused Knife Switch Type
Does not exist
Molded Case Circuit Breaker Type
Inspected
Instance
3rd Floor - Cage Area In Cafeteria
2- Between Good and Fair
Instance Condition
Instance Quantity
Instance Quantity Uom
1
EACH
Manufacturer
EquipmentId
Siemens
N/A
Mobile Validity Version 2.0 (P)
Page 5 of 7
Print Date: 6/18/2015
NYC Department of Education
Building Condition Assessment Survey 2014-2015
Electrical Inspection
M807
Question
Response
SWITCHBOARD
Molded Case Circuit Breaker Type
Capacity/Size Quantity
Capacity/Size UOM
Capacity/Size 2 Quantity
Capacity/Size 2 UOM
Source of Capacity/Size
400
Amps Total
1
Section(s)
Service Switch Size
2003
Documented
Installation Year
Source of Installation Year
Deficiency
Deficiency Quantity
SWITCHBOARD ID IS MISSING
1
EACH
MAINTENANCE
PRIORITY 2
LEVEL 2
No violations recorded
Quantity Uom
Potential Action
Urgency of Action
Purpose of Action
Violations
Deficiency
Deficiency Quantity
SWITCHBOARD NAME PLATE IS MISSING
1
EACH
MAINTENANCE
PRIORITY 2
LEVEL 2
No violations recorded
Quantity Uom
Potential Action
Urgency of Action
Purpose of Action
Violations
Inspected
TELEPHONE SYSTEM
Inspected
PBX/Intercom
3- Fair
Condition
Deficiency
No deficiencies recorded
Inspected
Standard
3- Fair
Condition
Deficiency
No deficiencies recorded
Inspected
TOILET ROOM - STAFF
Inspected
Lighting
Inspected
Lighting Fixture - Fluorescent
Pendant Mounted
Does not exist
Recessed Mounted
Inspected
2- Between Good and Fair
Condition
Deficiency
No deficiencies recorded
Inspected
Surface Mounted
2- Between Good and Fair
Condition
Deficiency
No deficiencies recorded
Lighting Fixture - HID
Does not exist
Lighting Fixture - Incandescent
Does not exist
Lighting Fixture - LED
Does not exist
Inspected
TOILET ROOM - STUDENT
Inspected
Lighting
Inspected
Lighting Fixture - Fluorescent
Inspected
Pendant Mounted
2- Between Good and Fair
Condition
Deficiency
No deficiencies recorded
Recessed Mounted
Does not exist
Surface Mounted
Inspected
2- Between Good and Fair
Condition
Deficiency
No deficiencies recorded
Lighting Fixture - HID
Does not exist
Lighting Fixture - Incandescent
Does not exist
Lighting Fixture - LED
Does not exist
Mobile Validity Version 2.0 (P)
Page 6 of 7
Print Date: 6/18/2015
NYC Department of Education
Building Condition Assessment Survey 2014-2015
Electrical Inspection
M807
Question
Response
TRANSFORMER
Does not exist
TV SYSTEM
Does not exist
Mobile Validity Version 2.0 (P)
Page 7 of 7
Print Date: 6/18/2015