Top of Shaft Extend as required Top of Shaft Top of Shaft (Typ) (See Bent 1 See Table for length L. 2 When steel does not extend the full shaft Details or Common length, the Contractor must demonstrate Foundation Details adequacy of the temporary support procedures to the satisfaction of the Engineer. (FD) standard) 3 Vertical bars may be supported on bottom of drilled hole if material is firm enough to Spiral elsewhere in the plans. bars as required (See Bent Details or Common Foundation 6" ~ ~ Spiral Dia ~ Number and size of Details (FD) standard) Spiral 4" Band at bottom Remaining vertical Termination reinforcing may of vertical terminate here. 2 Drilled Shaft Termination Drilled Shaft Drilled Shaft Diameter Diameter reinforcing. 2 of vertical reinforcing. 2 Bottom of Shaft 3 Bottom of Shaft 3 ~ ~ 6" 6" terminate here One and a half flat turns top and bottom reinforcing may 4' -0" M ax Half the vertical Diameter Provide spiral of the pitch and diameter shown ~ Length L Spiral 2" Bands Eq Spa at Greater of 2L or 75 percent of plan shaft length Length L 1 GENERAL NOTES: All welded bands and reinforcing steel, including that projecting the required amount from the top of the shaft, are subsidiary to the bid item, "Drilled Shafts". Do not tack weld spiral to main steel in the upper 15' of drilled shaft. Bottom of Shaft 3 VERTICAL REINFORCING OPTION LATERAL REINFORCING OPTIONS (Lateral reinforcing not shown for clarity) (Vertical reinforcing not shown for clarity) SPIRAL DETAIL 4 These details may only be used for bridge LENGTH L Drilled Shaft Diameter foundations not in or adjacent to waterways. They may only be used for multi-column bents Length L Note and abutments, excluding abutments supported by drilled shaft retaining walls. Other (Inches) (Feet) The length L is measured applications must receive approval of the 18 & 24 24 from top of shaft, natu- Engineer. 30 & 36 30 ral ground, or finished Typ 1 4 1 Typ 1 2 1 4 1 Typ 1 4 1 2 2 42 & larger 10 Shaft Diameters Bar 3 8 x 2 Bar (ASTM-A36) 3 8 x 2 Bar (ASTM-A36) 3 8 ground, whichever results in the longer length of full reinforcement. Bridge Division Standard x 4 (ASTM-A36) OPTIONAL DRILLED SHAFT REINFORCING 3 8" Typ ( Ty p) Max 3 per Band TOP INTERIOR BOTTOM ODSR FILE: FILE: The use of this standard is governed by the " Texas Engineering Practice Act" . No warranty of any of this standard to other form ats or for incorrect results or dam ages resulting from its use. kind is m ade by TxDOT for any purpose whatsoever. TxDOT assum es no responsibility for the conversion 1 ELEVATIONS DATE: DISCLAIM ER: do so when concrete is placed 4 BAND DETAILS C TxDOT odsstde1.dgn January 2015 DN: TxDOT CONT SECT CK: TxDOT JOB DW: TxDOT CK: TxDOT HIGHWAY REVISIONS DIST COUNTY SHEET NO.