Outline principle

advertisement
Outline principle
SMO 40 with multiple air/water heat pumps, additional heat and accessory (liquid condensation)
Application
Buildings with water-borne heating systems.
Alternative
Heat pump
Quantity
☑ 2x (Slave 2)
☐ 3x (Slave 3)
☐ 4x (Slave 4)
☐ 5x (Slave 5)
☐ 6x (Slave 6)
☐ 7x (Slave 7)
☐ 8x (Slave 8)
☐ Hot water charging
1 x ☐ VPA
2 x ☐ VPA
3 x ☐ VPA
4 x ☐ VPA
☐ VPB
☐ VPB
☐ VPB
☐ VPB
Select location of reversing valve that
charges hot water:
-AA25-BT25
-RM21
☐ Slave 1 ☐ Slave 2 ☐ Slave 4
-AA25-GP10
-AA25-BT71
☐ Additional water heater
☐ Hot water comfort with core water heater
☐ Hot water comfort with extra
hot water and additional core water heater
☐ Solar coil in VPA 1 (VPAS) / VPB1 (VPBS)
☐ Extra additional heat
☐ Electric boiler (step controlled)
☐ Combustion boiler (shunt controlled)
☐ District heating (shunt controlled)
☐ Extra climate system
☐ Extra climate system 1
☐ Extra climate system 2
☐ Extra climate system 3
-AA25
☐ UKV
☐ 2 pipe, Low tempered unbalanced low
flow
☐ 2 pipe, High tempered low flow
-AA25-EB102
-EB102
☐ POOL
☐ Pool system 1
-FL10
-BT3
Select location of reversing valve that
charges pool:
☐ Slave 1 ☐ Slave 2
-BT12
☐ Slave 4
☐ Pool system 2
-QM31
-QM32 -GP12
-RM11
-HQ1 -QM43
-QM1
-AA25-EB101
-EB101
-BT12
-FL10
-BT3
-QM31
-QM32 -GP12
-RM11
-AA25
-BT1
-HQ1 -QM43
-FL2
-QM1
-CM1
Start again
NOTE! This is an outline diagram. Actual installation must be engineered according to current standards.
See the appropriate "installer manual" for more information.
Designations according to standard IEC 81346-1 and 81346-2.
NIBE AB - Energy Systems Box 14, 285 21 Markaryd Tel 0433 - 73 000 Fax 0433 - 73 190 www.nibe.se
ODM GB 1412-1
M11624
PAGE 1 (4)
Function
SMO 40 with multiple air/water heat pumps, additional heat and accessory (liquid condensation)
Operate modes
• Activating temporary lux (extra hot water)
Pool
• External adjustment of the flow temperature
This function requires accessory POOL 40. A reversing valve
• Switch for "SG ready"
and a circulation pump can be connected to control all of
Heat production
All control signals should occur with potential-free relays. the charge flow from the heat pump(s) to a pool exchanger.
The heating control system on the SMO 40 is controlled
SMO 40 can control 2 pools; 2 x accessoriesPOOL 40 are
by the outside temperature. This means that the supply
AUX outputs
then required.
of heat to the house is regulated in accordance with the
It
is
possible
to
have
an
external
connection
through
the
During pool heating the heating medium is circulated
chosen setting of the regulating curve (curve slope and
offset). After adjustment, the correct amount of heat for relay function via a potential free variable relay (max 2 A) between the heat pump(s) and the pool exchanger using
circulation pump GP12.
the outside temperature is supplied. The supply tempera- on the input card (AA3), terminal block X7.
ture of SMO 40 will hover around the required value. For • Optional functions for external connection:
subnormal temperatures the control system calculates a
• Indication of buzzer alarm signal (preselected at the
External additional heat
heating deficit in the form of "degree-minutes",・which
factory).
means that heating production is accelerated. The larger
This function requires accessory AXC30. This accessory
the subnormal temperature, the greater the heat produc- • Control of circulation pump for hot water circulamakes external additional heat possible in three different
tion.
tion. The internal immersion heater is connected autoways, the selection is made in the controls.
matically when the energy requirement exceeds the heat • External circulation pump (for heating medium).
pumps' capacity.
• External alarm (NO/NC).
Gas/oil fired boiler
• Blocking heating.
A circulation pump is activated when the temperature
Hot water production
If any of the above is installed to terminal block X7 it
of the boiler sensor has exceeded the temperature set in
must be selected in the control system.
During hot water demand, SMO40 prioritises the heat
SMO 40. The heat is shunted to the requested temperapumps that are selected for hot water production for this. The accessory card is required if two or more of the
ture using the internal shunt.
above functions are to be connected to terminal block X5
Maximum time for hot water charging can be adjusted
in the menu system. Hot water charging starts when the at the same time.
Electric heater
hot water sensor has fallen to the set start temperature.
Hot water charging stops when the hot water temperaWhen the degree minute deficit is below the set value, a
ture on the hot water sensor (BT6) has been reached. For Room control
circulation pump is activated and the electric heater steps
occasional higher demand for hot water, the "temporary SMO 40 can be supplemented with a room sensor
in as needed.
(BT50).
lux"・function can be used to raise the temperature for
3 – 12 hours (selected in the menu system). Periodic hot The room temperature sensor has up to three functions:
water increase is factory set to every 14 days.
Hot water comfort
• Show current room temperature in the heat pump's
This function requires accessory AXC 30, which allows
display.
temporary lux, mixing valve and hot water circulation.
• Option of changing the room temperature in °C.
Functions/accessories
• Makes it possible to change/stabilise the room temperature.
Install the sensor in a neutral position where the set temHeat pumps
perature is required. A suitable place is on a free inner
Heat pumps with on/off compressor.
wall in a hall approx. 1.5 m above the floor. It is imporThe entire compressor output is routed to heating, hot
tant that the sensor is not prevented from measuring the
water or any pool heating. Compressors step in if needcorrect room temperature by being located, for example,
ed. If the output of all available compressors is not suffiin a recess, between shelves, behind a curtain, above or
cient, additional heat engages automatically.
close to a heat source, in a draft from an external door
Heat pumps with inverter compressor. The compres- or in direct sunlight. Closed radiator thermostats can also
sor output is adjusted according to the demand and rout- cause problems.
ed to heating, hot water or any pool heating or cooling.
The heat pump operates without the sensor, but if you
Compressors step in if needed. If the output of all availawant to read off the accommodation's indoor temperable compressors is not sufficient, additional heat engages
ture in the SMO 40 display, the sensor must be installed.
automatically
AUX inputs
SMO 40 has software controlled inputs for connecting
the switch function or sensor. This means that when an
external switch function or sensor is connected to one of
six AUX connections, the correct function must be selected for the correct connection.
For further information see the Installer's manual.
The following functions can be controlled:
• Blocking of additional heat and/or compressor
• Tariff blocking
Extra climate system
This function requires accessory ECS 40/ECS 41. A shunt
valve, supply and return sensor and a circulation pump
are connected to a second heating circuit with a lower
temperature demand (e.g. underfloor heating system).
The temperature in the extra climate system is controlled
by the heat pump and the shunt valve by offsetting the
heat curve (each climate system has its own heat curve),
room sensor or room unit. Up to 3 extra climate systems
can be connected to SMO 40.
Temporary lux (extra hot water)
If an immersion heater is installed in the tank it can be
used to raise the temperature of the hot water, to a
temperature that exceeds the operating range of the
heat pump. In addition, it can be permitted to produce
hot water, at the same time as the heat pump prioritises
heating.
Mixer valve
A temperature sensor reads the temperature of the outgoing hot water to the domestic hot water and adjusts
the mixing valve from the water heater until the set temperature has been reached.
Hot water circulation (VVC)
One pump can be controlled for the circulation of the hot
water during selectable periods.
Sun
This function requires accessory Solar 40/42 as well as a
pump station. The solar panel can be used to heat the
hot water.
NIBE AB - Energy Systems Box 14, 285 21 Markaryd Tel 0433 - 73 000 Fax 0433 - 73 190 www.nibe.se
ODM GB 1412-1
M11624
PAGE 2 (4)
List of Components
SMO 40 with multiple air/water heat pumps, additional heat and accessory (liquid condensation)
Pos
Name
Product name
Supplier
Part no.
AA25
BT1
BT6
BT7
BT25
BT50
BT63
Control module
Outdoor sensor
Temperature sensor, hot water charging
Temperature sensor, hot water top
Temperature sensor, external supply
Room sensor
Temperature sensor, external supply line after "additional heating before QN10"
Temperature sensor, external return line
Circulation pump, heating medium
Reversing valve, hot water/heating medium
Pool system 1
Unit box
Temperature sensor, pool
Heat exchanger, pool
Circulation pump, pool
Particle filter
Reversing valve, pool
Trim valve
Additional heat
Electric heater
Auxiliary relay/Contactor
Immersion heater
Immersion heater
SMO 40
NIBE
NIBE
NIBE
NIBE
NIBE
NIBE
NIBE
067 225
Auxiliary relay/Contactor
Heat pump system
Temperature sensor, return line
Temperature sensor, condenser supply line
Heat pump
Charge pump
BT71
GP10
QN10
CL11
AA25
BT51
EP5
GP9
HQ4
QN19
RN10
EB1
EB1
KA1
EB20
EB20
KA1
EB101
BT3
BT12
EB101
GP12
HQ1
QM1
QM31 to 32, QM43
RN10
EM1
AA25
BT52
CM1
EM1
FL2
KA1
QN11
EP21
AA25
BT2
BT3
GP20
QN25
Included
Included
Included
Included
Included
Included
NIBE
VST 05/VST 11/VST 20
POOL 40
POOL 40
NIBE
–
NIBE
NIBE
in
in
in
in
in
in
SMO
SMO
SMO
SMO
SMO
SMO
40
40
40
40
40
40
Included in SMO 40
089 982 /089 152 / 089 388
067 062
067 062
Tel.: 08 - 59 41 10 50
Tel.: 08 - 59 41 10 50
Tel.: 08 - 59 41 10 50
POOL 40
NIBE
–
067 062
ELK 15/ELK 26/ELK 42
HR 10
NIBE
NIBE
069 022/ 067 074/ 067 075
067 309
IU (immersion heater) + K11 (terminal block)
NIBE
HR 10
NIBE
IU 3kW: 218 009
IU 6kW: 218 011
IU 9kW: 218 003
K11: 188 93
067 309
F2025/F2026//F2030/F2040/F2300
CPD 11
NIBE
NIBE
NIBE
NIBE
Particle filter
Drain valve, heating medium
Shut-off valve
Trim valve
External addition
Unit box
Temperature sensor, boiler
Expansion vessel, closed
Oil, gas, pellets or wood boiler
Safety valve
Auxiliary relay/Contactor
Shunt valve
Extra climate system
Unit box
Temperature sensor, heating medium supply
Temperature sensor, heating medium return
Circulation pump
Shunt valve
Remarks
Included in F2025/F2026//F2030/F2040/F2300
Included in F2025/F2026//F2030/F2040/F2300
F2025/F2026/F2300: The software must be 55 or later.
(CPD 11-25/65: 067 321
CPD 11-25/75: 067 320
NIBE
Included in F2025/F2026//F2030/F2040/F2300
Certain boilers have their own circulation pumps, if not they must be equipped
with a flow guard.
AXC 30
AXC 30
NIBE
NIBE
067 304
067 304
HR 10
NIBE
067 309
NIBE
NIBE
NIBE
NIBE
NIBE
067
067
067
067
067
ECS
ECS
ECS
ECS
ECS
40/ECS
40/ECS
40/ECS
40/ECS
40/ECS
41
41
41
41
41
287/067
287/067
287/067
287/067
287/067
288
288
288
288
288
NIBE AB - Energy Systems Box 14, 285 21 Markaryd Tel 0433 - 73 000 Fax 0433 - 73 190 www.nibe.se
ODM GB 1412-1
M11624
PAGE 3 (4)
Pos
Name
QZ1
Hot water circulation
Circulation pump
GP11
Other information
CM1
CP5
Product name
Expansion vessel, closed
Buffer vessel, UKV
UKV
UKV
UKV
UKV
CP10
Accumulator tank with hot water heating
EB10
FL2
Additional water heater
Safety valve, Heating medium
Control module
Air/water heat pump
Accumulator with hot water heater
SMO 40 with multiple air/water heat pumps, additional heat and accessory (liquid condensation)
Part no.
Remarks
Supplier
100
200
300
500
VPA 300/200
VPA 450/300
VPAS 300/450
VPB 500
VPB 750-2
VPB 1000
Circ. pump
NIBE
NIBE
NIBE
NIBE
NIBE
NIBE
Water heater
HW Control
Addition
088
080
080
080
207
321
330
302
088
088
087
083
083
083
710
660
720
220
231
240
Note that the tank must be able to receive the heat pump charge effect. See the
last page for a table of possible combinations of NIBE's range.
Volume vessel
F2030 – 7 kW
F2030 – 9 kW
F2040 – 8 kW
VPA 300/200
VPA 450/300
SMO 40
F2040 – 12 kW
VPAS 300/450
F2040 – 16 kW
VPB 500
VPB 750-2
VPB 1000
F2300 – 14 kW
F2300 – 20 kW
CPD 11-25/65
CPD 11-25/75
VPB 200
VPB 300
VPBS 300
VPB 500
VPB 750-2
VPA 450/300
VPAS 300/450
VPB 750-2
VPB 1000
VST 11
ELK 15
ELK 26
ELK 42
VST 20
UKV 100
UKV 200
UKV 300
UKV 500
VST 11
VST 20
VST 20
NIBE AB - Energy Systems Box 14, 285 21 Markaryd Tel 0433 - 73 000 Fax 0433 - 73 190 www.nibe.se
ODM GB 1412-1
M11624
PAGE 4 (4)