Eaton is dedicated to ensuring that reliable, efficient and safe power is available when it’s needed most. With unparalleled knowledge of electrical power management across industries, experts at Eaton deliver customized, integrated solutions to solve our customers’ most critical challenges. Our focus is on delivering the right solution for the application. But, decision makers demand more than just innovative products. They turn to Eaton for an unwavering commitment to personal support that makes customer success a top priority. For more information, visit www.eaton.com. MCCB 2011 Cover Spread.indd 1 Series C and Special Application Moulded Case Circuit Breakers Series C and Special Application Moulded Case Circuit Breakers © 2011 Eaton Corporation All Rights Reserved Printed in Canada Pub No. PG01200001K October 2011 Product Guide 2011 Eaton Corporation 1111 Superior Ave. Cleveland, OH 44114 United States 877-ETN-CARE (877-386-2273) Eaton.com Product Guide 2011 Canadian Operations 5050 Mainway Burlington, ON L7L 5Z1 Canada 1-800-268-3578 EatonCanada.ca Eaton is a registered trademark of Eaton Corporation. All trademarks are property of their respective owners. 9/20/11 10:38:17 PM F-Frame 2011 Page 15 Monday, September 19, 2011 9:30 PM F-3 Series C Moulded Case Circuit Breakers 10-225 Amperes F-Frame Catalogue Numbering System This information is presented only as an aid to understanding Catalogue numbers. It is not to be used to build Catalogue numbers for circuit breakers or trip units. 1 1 1 Circuit Breaker Catalogue Number FDC 3 100 L 1 1 Circuit Breaker Type EHD FDB FD HFD FDC Number of Poles 1: 1 Pole 2: 2 Poles 3: 3 Poles 4: 4 Poles Trip Amperes Suffix 10 15 20 25 30 35 40 45 50 60 70 80 90 100 110 125 150 175 200 225 E:100% Protected (4-Pole only) Neutral Pole EH: 50% Protected (4-Pole only) K:High Magnetic Moulded Case Switch L:Line and Load Terminals S:VISA breaker V:50˚C Calibration W:Without Terminals Y:Line Terminals Only Z:Aluminum Terminals SK: VISA - High Magnetic Moulded Case Switch 1 1 1 1 1 1 1 1 1 EDC 3 200 L FDE 3 225 32 ZG W 1 1 Circuit Breaker Type ED EDH EDC Number of Poles Trip Amperes 2: 2 Poles 3: 3 Poles 100 125 150 175 200 225 Suffix L: S: W: Y: Z: Line and Load Terminals VISA breaker Without Terminals Line Terminals Only Aluminum Terminals Circuit Breaker Type Number of Poles Trip Amperes 3: 3 Poles 80 160 225 FDE HFDE FDCE Trip Unit Suffix Suffix 33: LS 32: LSI 35: LSG 36: LSIG ZG: Zone Selective Interlocking –: Without ZSI W: Without Terminals L: Line and Load Terminals –: Load Terminals Only 1 1 1 1 1 1 Dimensions/Weights 1 Dimensions, Inches (mm) Approximate Shipping Weight, Lbs. (kg) 1 Number of Poles Width Height Depth 1 1.375 (35) 6 (152) 3.375 (86) Breaker Type 1 2 3 4 2 2.75 (70) 6 (152) 3.375 (86) ED, EDH, EDC – 3 (1.361) 4.5 (2.041) – 3 4.125 (105) 6 (152) 3.375 (86) EHD, FDB, FD, HFD, FDC 2 (.907) 3 (1.361) 4.5 (2.041) 6 (2.721) 4 5.5 (140) 6 (152) 3.375 (86) FDE, HFDE, FDCE – – 4.5 (2.041) – Number of Poles 1 1 1 1 1 1 “VISA” option is available. CSA listed only. Series C and Special Application Moulded Case Circuit Breakers PG01200001K—October 2011 www.eatoncanada.ca 15 F-Frame 2011 Page 16 Monday, September 19, 2011 9:30 PM F-4 1 1 1 1 1 1 10-225 Amperes F-Frame Product Selection Types ED, EDH, and EDC Thermal-Magnetic Circuit Breakers with Non-Interchangeable Trip Units Type EHD Thermal-Magnetic Circuit Breakers with Non-Interchangeable Trip Units 240 Vac Maximum, 125 Vdc 1 1 Series C Moulded Case Circuit Breakers 65 kAIC @ 240 Vac 100 kAIC @ 240 Vac Type EDC Current Maximum Type EDH ➁ Limiting ➁ Continuous Type ED ➁ Ampere 2-Pole 3-Pole 2-Pole 3-Pole 2-Pole 3-Pole Rating Catalogue Number (Includes Terminals on Load End Only) @ 40°C 100 125 150 175 200 225 ED2100 ED2125 ED2150 ED2175 ED2200 ED2225 ED3100 ED3125 ED3150 ED3175 ED3200 ED3225 EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225 EDH3100 EDH3125 EDH3150 EDH3175 EDH3200 EDH3225 277 Vac Maximum, 125 Vdc 480 Vac Maximum, 250 Vdc 200 kAIC @ 240 Vac EDC2100 EDC2125 EDC2150 EDC2175 EDC2200 EDC2225 EDC3100 EDC3125 EDC3150 EDC3175 EDC3200 EDC3225 Instruction Leaflet Number 29C101 1 1 1 14 kAIC @ 277 Vac 14 kAIC @ 480 Vac Maximum ➁ Type EHD Continuous Ampere 1-Pole 2-Pole 3-Pole Rating Catalogue Number (Includes Terminals on Load End Only) @ 40°C 10 15 20 25 30 35 40 45 50 60 70 80 90 100 – EHD2015 EHD2020 EHD2025 EHD2030 EHD2035 EHD2040 EHD2045 EHD2050 EHD2060 EHD2070 EHD2080 EHD2090 EHD2100 – EHD1015➀ EHD1020➀ EHD1025 EHD1030 EHD1035 EHD1040 EHD1045 EHD1050 EHD1060 EHD1070 EHD1080 EHD1090 EHD1100 – EHD3015 EHD3020 EHD3025 EHD3030 EHD3035 EHD3040 EHD3045 EHD3050 EHD3060 EHD3070 EHD3080 EHD3090 EHD3100 Instruction Leaflet Number 29C101 1 1 Type FDB and FD Thermal-Magnetic Circuit Breakers with Non-Interchangeable Trip Units 1 1 1 1 1 1 1 1 1 1 1 1 1 347 Vac Maximum, 125 Vdc 600 Vac Maximum, 250 Vdc 347 Vac Maximum, 125 Vdc 600 Vac Maximum, 250 Vdc 14 kAIC @ 347 Vac 14 kAIC @ 600 Vac 18 kAIC @ 347 Vac 18 kAIC @ 600 Vac Type FDB ➁ Maximum Continuous Ampere Rating @ 40°C 1-Pole➂ 10 15 20 25 30 35 40 45 50 60 70 80 90 100 110 125 150 175 200 225 – FDB1015➀ FDB1020➀ FDB1025 FDB1030 FDB1035 FDB1040 FDB1045 FDB1050 FDB1060 FDB1070 FDB1080 FDB1090 FDB1100 FDB1110 FDB1125 FDB1150 – – – Type FD ➁ 2-Pole 3-Pole 4-Pole 1-Pole 2-Pole 3-Pole 4-Pole – FDB4015 FDB4020 FDB4025 FDB4030 FDB4035 FDB4040 FDB4045 FDB4050 FDB4060 FDB4070 FDB4080 FDB4090 FDB4100 FDB4110 FDB4125 FDB4150 FDB4175➂ FDB4200➂ FDB4225➂ – FD1015➀ FD1020➀ FD1025 FD1030 FD1035 FD1040 FD1045 FD1050 FD1060 FD1070 FD1080 FD1090 FD1100 FD1110 FD1125 FD1150 – – – – FD2015 FD2020 FD2025 FD2030 FD2035 FD2040 FD2045 FD2050 FD2060 FD2070 FD2080 FD2090 FD2100 FD2110 FD2125 FD2150 FD2175 FD2200 FD2225 – FD3015 FD3020 FD3025 FD3030 FD3035 FD3040 FD3045 FD3050 FD3060 FD3070 FD3080 FD3090 FD3100 FD3110 FD3125 FD3150 FD3175 FD3200 FD3225 – FD4015 FD4020 FD4025 FD4030 FD4035 FD4040 FD4045 FD4050 FD4060 FD4070 FD4080 FD4090 FD4100 FD4110 FD4125 FD4150 FD4175 FD4200 FD4225 Catalogue Number (Includes Terminals on Load End Only) – FDB2015 FDB2020 FDB2025 FDB2030 FDB2035 FDB2040 FDB2045 FDB2050 FDB2060 FDB2070 FDB2080 FDB2090 FDB2100 FDB2110 FDB2125 FDB2150 FDB2175➂ FDB2200➂ FDB2225➂ – FDB3015 FDB3020 FDB3025 FDB3030 FDB3035 FDB3040 FDB3045 FDB3050 FDB3060 FDB3070 FDB3080 FDB3090 FDB3100 FDB3110 FDB3125 FDB3150 FDB3175➂ FDB3200➂ FDB3225➂ Instruction Leaflet Number 29C101 1 1 1 1 16 CSA and UL listed for SWD applications. When a “VISA” type breaker is required, add suffix ‘S’ to circuit breaker catalogue number, i.e., FD3150S. Available for 1-,2-,3-pole breakers. CSA listed only. Not UL listed. Series C and Special Application Moulded Case Circuit Breakers PG01200001K—October 2011 www.eatoncanada.ca F-Frame 2011 Page 17 Monday, September 19, 2011 9:30 PM Series C Moulded Case Circuit Breakers 10-225 Amperes F-Frame F-5 Types HFD and FDC Thermal-Magnetic Circuit Breakers with Non-Interchangeable Trip Units 347 Vac Maximum, 125 Vdc 600 Vac Maximum, 250 Vdc 347 Vac Maximum, 125 Vdc 600 Vac Maximum, 250 Vdc 25 kAIC @ 347 Vac 25 kAIC @ 600Vac 30 kAIC @ 347 Maximum Continuous Ampere Rating @ 40°C 1-Pole 15 20 25 30 35 40 45 50 60 70 80 90 100 110 125 150 175 200 225 HFD1015➀➁ HFD1020➀➁ HFD1025➁ HFD1030➁ – – – – – – – – – – – – – – – – Type HFD ➂ 1 1 35 kAIC @ 600 Vac Type FDC ➂ 2-Pole 3-Pole 1 4-Pole 1-Pole 2-Pole 3-Pole 4-Pole HFD4015 HFD4020 HFD4025 HFD4030 HFD4035 HFD4040 HFD4045 HFD4050 HFD4060 HFD4070 HFD4080 HFD4090 HFD4100 HFD4110 HFD4125 HFD4150 HFD4175 HFD4200 HFD4225 FDC1015➀➁ FDC1020➀➁ FDC1025➁ FDC1030➁ – – – – – – – – – – – – – – – – FDC2015 FDC2020 FDC2025 FDC2030 FDC2035 FDC2040 FDC2045 FDC2050 FDC2060 FDC2070 FDC2080 FDC2090 FDC2100 FDC2110 FDC2125 FDC2150 FDC2175 FDC2200 FDC2225 FDC3015 FDC3020 FDC3025 FDC3030 FDC3035 FDC3040 FDC3045 FDC3050 FDC3060 FDC3070 FDC3080 FDC3090 FDC3100 FDC3110 FDC3125 FDC3150 FDC3175 FDC3200 FDC3225 FDC4015 FDC4020 FDC4025 FDC4030 FDC4035 FDC4040 FDC4045 FDC4050 FDC4060 FDC4070 FDC4080 FDC4090 FDC4100 FDC4110 FDC4125 FDC4150 FDC4175 FDC4200 FDC4225 1 Catalogue Number (Includes Terminals on Load End Only) HFD2015 HFD2020 HFD2025 HFD2030 HFD2035 HFD2040 HFD2045 HFD2050 HFD2060 HFD2070 HFD2080 HFD2090 HFD2100 HFD2110 HFD2125 HFD2150 HFD2175 HFD2200 HFD2225 HFD3015 HFD3020 HFD3025 HFD3030 HFD3035 HFD3040 HFD3045 HFD3050 HFD3060 HFD3070 HFD3080 HFD3090 HFD3100 HFD3110 HFD3125 HFD3150 HFD3175 HFD3200 HFD3225 1 1 1 1 1 1 1 1 1 Instruction Leaflet Number 29C101 1 Types FDE, HFDE and FDCE Electronic Circuit Breakers with Non-Interchangeable Trip Units Maximum Ampere Rating Neutral ➃ CT for LSG and LSIG LS LSI LSI w/ZSI LSG LSIG LSIG w/ZSI Catalogue Number Catalogue Number Catalogue Number Catalogue Number Catalogue Number Catalogue Number FDE308033 FDE316033 FDE322533 FDE308032 FDE316032 FDE322532 FDE308032ZG FDE316032ZG FDE322532ZG FDE308035 FDE316035 FDE322535 FDE308036 FDE316036 FDE322536 FDE308036ZG FDE316036ZG FDE322536ZG HFDE308033 HFDE316033 HFDE322533 HFDE308032 HFDE316032 HFDE322532 HFDE308032ZG HFDE316032ZG HFDE322532ZG HFDE308035 HFDE316035 HFDE322535 HFDE308036 HFDE316036 HFDE322536 HFDE308036ZG HFDE316036ZG HFDE322536ZG FDCE308033 FDCE316033 FDCE322533 FDCE308032 FDCE316032 FDCE322532 FDCE308032ZG FDCE316032ZG FDCE322532ZG FDCE308035 FDCE316035 FDCE322535 FDCE308036 FDCE316036 FDCE322536 FDCE308036ZG FDCE316036ZG FDCE322536ZG 1 1 IC Rating 18 kAIC at 600 Vac 80 160 225 CTF080 CTF160 CTF225 1 1 IC Rating 25 kAIC at 600 Vac 80 160 225 CTF080 CTF160 CTF225 1 1 IC Rating 25 kAIC at 600 Vac 80 160 225 CTF080 CTF160 CTF225 1 1 1 Breaker Mount Ammeter Description Catalogue Number Breaker Mount Ammeter and Cause of Trip Display Remote Mount Ammeter and Cause of Trip Display DIGIVIEW DIGIVIEWR06 1 1 Note: Use on FDE, HFDE and FDCE electronic trip only. 1 Ammeter 1 1 CSA and UL listed for SWD applications. 1-pole circuit breaker interrupting ratings @ 347 Vac are listed with CSA only. Not UL listed. When a “VISA” type breaker is required, add suffix ‘S’ to circuit breaker catalogue number, i.e., HFD2020S. Available for 1-,2-,3-Pole breakers except 2-,3-Pole only for type FDC breaker. Required for ground fault measurement in 3 phase 4 wires system with phase to neutral load. Not supplied with the breaker, must be ordered separately. FDE, HFDE, FDCE Electronic Circuit Breakers with optional Zone Selective Interlocking function. Series C and Special Application Moulded Case Circuit Breakers PG01200001K—October 2011 www.eatoncanada.ca 1 1 17