INSTALLATION INSTRUCTIONS ! ES3-DAINTOCC THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH APPLICABLE BUILDING AND ELECTRICAL CODES, BY A QUALIFIED PERSON WHO IS FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. ES3-DAINT MOUNTING INSTRUCTIONS 1. IDENTIFY FIXTURE AND PLAN LABELS PROVIDED WITH ES3-DAINTOCC MODULE. ATTACH THE FIXTURE LABEL TO THE OUTSIDE OF THE FIXTURE IN A LOCATION AS DIRECTED BY OWNERS REPRESENTATIVE. ATTACH THE PLAN LABEL AT THE CORRESPONDING FIXTURE LOCATION ON THE FACILITY FLOOR PLAN. 2. OPEN WIREWAY COVER, DO NOT ATTEMPT TO REMOVE WIREWAY COVER FROM FIXTURE. MOUNT THE ES3-DAINTOCC MODULE TO THE WIREWAY COVER USING THE INCLUDED RETENTION NUT. 3. REMOVE THE INCLUDED JUMPER HARNESS AND MAKE ELECTRICAL CONNECTIONS AS INDICATED ON WIRING DIAGRAMS PAGE. 4. PERFORM INSTALLATION TEST, (SEE BELOW.) 5. CLOSE WIREWAY COVER. SELECT APPROPRIATE LENS COVER (20’ OR 40’ MOUNTING) AND ATTACH TO THE ES3-DAINTOCC. 6. REFER TO ESSENTIALS SERIES INSTALLATION INSRUCTIONS FOR MOUNTING INSTRUCTIONS. 7. CONTACT DAINTREE REPRESENTATIVE TO COMPLETE COMSSIONING OF FIXTURES AND THE CONTROLSCOPE NETWORK. ESSENTIALS FIXTURE WIREWAY COVER LONG MODULE ESSENTIALS FIXTURE WIREWAY COVER SHORT MODULE SENSOR RETENTION NUT (BY FLEXTRONICS) DAINTOCC SENSOR (BY FLEXTRONICS) DAINTOCC LENS (BY FLEXTRONICS) NOTE: WIRING NOT SHOWN. SEE WIRING DIAGRAM PAGE. ES3-DAINTOCC INSTALLATION TEST 1. 2. 3. 4. 5. 6. PRESS AND IMMEDIATELY RELEASE THE RESET BUTTON. THE RED ERROR LED FLASHES ONCE, THEN PAUSES AND REPEATS. CHECK THAT THE CONNECTED LIGHTS CYCLE FROM MINIMUM TO MAXIMUM BRIGHTNESS THEN TURN OFF, THEN REPEAT THE CYCLE. PRESS AND IMMEDIATELY RELEASE THE RESET BUTTON AGAIN. THE RED ERROR LED FLASHES TWICE, THEN PAUSES AND REPEATS. TRIGGER THE OCCUPANCY SENSOR. THE LIGHT CONNECTED TO THE BALLAST TURNS ON. WHEN THE SENSOR TIMES OUT THE LIGHT TURNS OFF. PRESS AND IMMEDIATELY RELEASE THE RESET BUTTON TO EXIT TESTING. PRESS AND HOLD THE RESET BUTTON ON THE ES3-DAINTOCC FOR 3 SECONDS TO RESET THE UNIT. RELEASE THE BUTTON WHEN THE GREEN JOINED LED AND THE RED ERROR LEDS BEGIN FL ASHING. TROUBLESHOOTING IF THE INSTALLATION TEST PROCEDURE FAILS: 1. CONFIRM THAT THE ES3-DAINT (WFA100) IS POWERED. (RED AND GREEN LED LIGHTS SHOULD BE ON) 2. CHECK THE CONNECTIONS FROM THE ES3-DAINT TO THE POWER SUPPLIES. 3. CHECK TO BE SURE THE FACTORY INSTALLED JUMPERS ON THE ES3-DAINT ARE EITHER IN PLACE OR REMOVED AS APPROPRIATE: - CONNECTED TO A 0-10V DIMMING POWER SUPPLY, REMOVE THE JUMPER FROM THE VIOLET AND GRAY TERMINALS. - NOT CONNECTED TO AN OCCUPANCY SENSOR, BE SURE THE JUMPER IS CONNECTED BETWEEN THE BLUE AND GRAY TERMINALS. 4. PRESS AND HOLD THE RESET BUTTON FOR 3 SECONDS TO RESET THE ES3-DAINT. 5. PERFORM THE INSTALLATION TEST AGAIN. IF THE LIGHTS DO NOT TURN OFF DURING THE OCCUPANCY SENSOR TEST: 1. MAKE SURE THE SENSOR IS NOT DETECTING OCCUPANCY. 2. CHECK THE OCCUPANCY SENSOR TIME DELAY AND MAKE SURE IT IS SET FOR MINIMUM. CONTACT DAINTREE TO COMPLETE COMSSIONING OF FIXTURES AND THE CONTROLSCOPE NETWORK. www.flextronics.com/lighting lighting@flextronics.com 913-851-3000 Flextronics is a leading Electronics Manufacturing Services (EMS) provider that offers complete design, engineering, and manufacturing services to aerospace, automotive, computing, consumer digital, industrial, infrastructure, medical and mobile OEM customers. With a network of facilities in 30 countries, Flextronics helps customers design, build , ship, and service electronics products worldwide. Flextronics Lighting Solutions is a business unit within the Flextronics Energy division. PN: 001-0389-01 ES3-DAINTOCC WIRING DIAGRAMS ! THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH APPLICABLE BUILDING AND ELECTRICAL CODES, BY A QUALIFIED PERSON WHO IS FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. DO NOT MODIFY: SWITCHED LOAD CONNECTION - RED POWER SUPPLY LEAD - BLACK A/C POWER NEUTRAL CONNECTION WHITE POWER SUPPLY LEAD - WHITE RED WHITE A/C POWER LINE CONNECTION BLACK GREY BLACK PURPLE DO NOT MODIFY: DIMMING LEAD CONNECTION - PURPLE DO NOT MODIFY DIMMING LEAD CONNECTION - GREY FOR CONNECTION TO ES3-DAINTOCC ASSEMBLY POWER SUPPLY ASSEMBLY (LOCATED INSIDE FIXTURE WIREWAY) JUMPER HARNESS (REMOVE DURING FINAL ASSEMBLY) FOR CONNECTION TO POWER SUPPLY ASSEMBLY ES3-DAINTOCC ASSEMBLY (PACKAGED SEPARTELY) ! www.flextronics.com/lighting lighting@flextronics.com 913-851-3000 Flextronics is a leading Electronics Manufacturing Services (EMS) provider that offers complete design, engineering, and manufacturing services to aerospace, automotive, computing, consumer digital, industrial, infrastructure, medical and mobile OEM customers. With a network of facilities in 30 countries, Flextronics helps customers design, build , ship, and service electronics products worldwide. Flextronics Lighting Solutions is a business unit within the Flextronics Energy division. PN: 001-0389-01 WARNING - RISK OF ELECTRICAL SHOCK DISCONNECT ELECTRICAL POWER PRIOR TO PERFORMING MAINTENANCE ON THE FIXTURE.