CAUTION 3-PIN Installed in non-readily accessible indoor locations only INSTALLATION INSTRUCTIONS ALWAYS remove plug and flexible cord at the outlet: Pull plug perpendicular to the outlet face whilst supporting the outlet PRODUCT OVERVIEW ST20XX Coupler lead Installed, tested and modified by a qualified electrician in accordance to AS/NZS 3000 Wiring Rules Do NOT open or modify any installation coupler or attached cable in any way INSTALLATION COUPLER SYSTEM DC20 Dust Cover AT20XX Coupler Junction lead Standards Compliance: all relevant parts of AS/NZS 3100, 3112, 61535.1 Certification Numbers: A/12312E, A/13144E Insulating Material: Polycarbonate Recyclability: Contact WireByClick on 1300 546 449 for product take-back IMPORTANT - READ BEFORE INSTALLATION OR MODIFICATION PERSONS INSTALLING OR MODIFYING WireByClick installation couplers must be installed, tested and modified only by adequately qualified electricians in accordance with AS/NZS 3000 Wiring Rules INSTALLATION LOCATION All WireByClick products must be installed indoors and in non-readily accessible locations in accordance with AS/NZS 3000 Wiring Rules MP20 Mounting Plate STANDARDS REQUIREMENTS All couplers and attached cables must be suitably mounted and secured in accordance with AS/NZS 3000 Wiring Rules. Ensure couplers, cables and any connected plugs and flexible cords are never under any excessive strain UNUSED OUTLETS Any unused outlets are to be fitted with a dust cover (cat. no. DC20) to prevent ingress of dust and for increased protection FIXING OF “T” MODULE COUPLER Two methods are available for securing “T” outlet couplers: FIXING WITH CABLE TIES FIXING WITH MP20 MOUNTING PLATE: Ensure mounting plate legs ALWAYS face UP when mounting to a vertical surface USE WITH OTHER SYSTEMS WireByClick installation couplers are NOT for use with any other coupler system. DO NOT attempt to plug any non WireByClick coupler or plug into any WireByClick product, other than the appropriate standard plug as defined in AS 3112 Section 2 CONNECTION To connect couplers, simply plug together ensuring side retaining clip is latched. You should hear an audible “Click” when two couplers are correctly engaged DISCONNECTION Unplugging of an attached plug and flexible cord MUST only be performed by competent persons (as defined in AS/NZS 3000 Wiring Rules) and done so according to the image below and NEVER under load Coupler disconnection MUST only be performed by qualified electricians and NEVER done so under load in accordance with AS/NZS 3000 and 61535.1, ALWAYS ISOLATE THE CIRCUIT PRIOR TO ANY WORKS. “XX” denotes cable length e.g. “30” = 3m lead MOUNTING & FIXING INSTRUCTIONS RCD PROTECTION All WireByClick installations MUST be protected by an RCD in accordance with AS/NZS 3000 - Part 2 JUNCTIONS/T-OFFS Coupler junctions to be NO more than four (4) modules high (including plug with flexible cord) S20 end-of-line Adapter T2005/J 0.5m Starter lead w/ Junction Box TECHNICAL SPECIFICATIONS Classification: Installation Couplers, 3-Pole type Rated Voltage: 250V a.c. single-phase Rated Current: 20A Cable: 2.5mm 2C+E flat, 450/750V insulated to AS/NZS 5000.2 Degree of Protection: IP2XC ST20XX Coupler lead Cable ties up to 6mm wide can be threaded through dedicated slots on the Base for secure fixing MP20 Mounting plate can be screw-fixed to a hard surface and “T” module pushed onto and securely clipped to legs using the cable-tie slots JUNCTION BOX & WBC LUMINAIRE PLUG WIRING WireByClick Installation Couplers use 2.5mm conductors for ALL conductors and are rated at 20A WireByClick 3-Pin Luminaire Plugs (cat. no. L1018) use 1mm conductors and are rated at 10A ALWAYS ensure Luminaire Plug wiring corresponds to the wiring of the Junction Box for each circuit ACTIVE EARTH NEUTRAL ACTIVE EARTH NEUTRAL Sheath diameter 7.0 +/-0.2mm To remove connected plug, pull plug perpendicular to outlet face whilst supporting outlet. NEVER pull on cord to remove To disconnect couplers, un-latch side retaining clip whilst pulling couplers apart Junction Box/Starter wiring 1300 546 449 L1018 Luminaire Plug wiring wirebyclick.com © 2012 WBC Group Pty Ltd All rights reserved rev01 CAUTION 5-PIN L10XX Luminaire Plug with flexible cord Installed, tested and modified by a qualified electrician in accordance to AS/NZS 3000 Wiring Rules INSTALLATION COUPLER SYSTEM Do NOT open or modify any installation coupler or attached cable in any way INSTALLATION INSTRUCTIONS ALWAYS remove luminaire plug and flexible cord at the outlet: Pull plug perpendicular to the outlet face whilst supporting the outlet TECHNICAL SPECIFICATIONS Classification: Installation Couplers, 5-Pole type Rated Voltage: 250V a.c. single-phase Rated Current: 20A Cable: 2.5mm 4C+E round, 450/750V insulated to AS/NZS 5000.2 Degree of Protection: IP3X PRODUCT OVERVIEW Installed in non-readily accessible indoor locations only Standards Compliance: all relevant parts of AS/NZS 3100, 3112, 61535.1 Certification Numbers: A/13294E, A/13144E Insulating Material: Polycarbonate Recyclability: Contact WireByClick on 1300 546 449 for product take-back IMPORTANT - READ BEFORE INSTALLATION OR MODIFICATION PERSONS INSTALLING OR MODIFYING WireByClick installation couplers must be installed, tested and modified only by adequately qualified electricians in accordance with AS/NZS 3000 Wiring Rules INSTALLATION LOCATION All WireByClick products must be installed indoors and in non-readily accessible locations in accordance with AS/NZS 3000 Wiring Rules RCD PROTECTION All WireByClick installations MUST be protected by an RCD in accordance with AS/NZS 3000 - Part 2 AT20XX/5 Coupler leads AT20XX/5 Coupler lead T2005/5J 0.5m Starter lead w/ Junction Box A10XX/5D lead for Dali sensors (with 2Cx1.5mm (10A)) MP20/5 Mounting Plate “XX” denotes cable length e.g. “30” = 3m lead MOUNTING & FIXING INSTRUCTIONS STANDARDS REQUIREMENTS All couplers and attached cables must be suitably mounted and secured in accordance with AS/NZS 3000 Wiring Rules. Ensure couplers, cables and any connected plugs and flexible cords are never under any excessive strain UNUSED OUTLETS Any unused outlets are to be fitted with a dust cover (cat. no. DC20/5) to prevent ingress of dust and for increased protection FIXING OF “T/5” MODULE COUPLER Two methods are available for securing “T/5” outlet couplers: FIXING WITH CABLE TIES FIXING WITH MP20/5 MOUNTING PLATE: USE WITH OTHER SYSTEMS WireByClick installation couplers are NOT for use with any other coupler system. DO NOT attempt to plug any non WireByClick coupler or plug into any WireByClick product, other than the appropriate standard plug as defined in AS 3112 Section 2 JUNCTIONS/T-OFFS Coupler junctions to be NO more than four (4) modules high (including luminare plug with flexible cord) CONNECTION To connect couplers, simply plug together ensuring side retaining clip is latched. You should hear an audible “Click” when two couplers are correctly engaged. Ensure luminaire plugs when installed face DOWN towards the light fittings (cord should direct down) DISCONNECTION Unplugging of an attached Luminaire plug and flexible cord MUST only be performed by competent persons (as defined in AS/NZS 3000 Wiring Rules) and done so according to the image below and NEVER under load Coupler disconnection MUST only be performed by qualified electricians and NEVER done so under load in accordance with AS/NZS 3000 and 61535.1, ALWAYS ISOLATE THE CIRCUIT PRIOR TO ANY WORKS. Ensure mounting plate legs ALWAYS face UP when mounting to a vertical surface Cable ties up to 6mm wide can be threaded through dedicated slots on the Base for secure fixing JUNCTION BOX & WBC LUMINAIRE PLUG WIRING WireByClick 5-Pin Luminaire Plugs (cat. nos. L1018/5 & L1025/5) use 1mm conductors and are rated at 10A ALWAYS ensure Luminaire Plug wiring corresponds to the wiring of the Junction Box for each circuit DALI / CONTROL 1* ACTIVE EARTH EARTH Junction Box/Starter wiring 1300 546 449 DALI / CONTROL 1* ACTIVE DALI / CONTROL 2 To disconnect couplers, un-latch side retaining clip whilst pulling couplers apart MP20/5 Mounting plate can be screw-fixed to a hard surface and “T/5” module pushed onto and securely clipped to legs using the cable-tie slots WireByClick Installation Couplers use 2.5mm conductors for ALL conductors and are rated at 20A NEUTRAL To remove connected plug, pull plug perpendicular to outlet face whilst supporting outlet. NEVER pull on cord to remove Ensure plug cord is facing down towards light fitting * Dali/Control 1 core maybe supplied in black or white insulation colour NEUTRAL DALI / CONTROL 2 Sheath diameter 9.2 +/-0.2mm 5-Pin Luminaire Plug wiring wirebyclick.com © 2014 WBC Group Pty Ltd All rights reserved rev02 CAUTION SWA 3-PIN SWA ADAPTER MODULE INSTALLATION INSTRUCTIONS Installed in non-readily accessible indoor locations only Installed, tested and modified by a qualified electrician in accordance to AS/NZS 3000 Wiring Rules Do NOT open or modify any installation coupler or attached cable in any way ALWAYS remove plug and flexible cord at the outlet: Pull plug perpendicular to the outlet face whilst supporting the outlet TECHNICAL SPECIFICATIONS Classification: Installation Coupler/Distribution Block, 3-Pole type Rated Voltage: 250V a.c. single-phase Rated Current: 20A (total) Degree of Protection: IP3X Standards Compliance: all relevant parts of AS/NZS 3100, 3112, 61535.1 Certification Numbers: A/12312E Insulating Material: Polycarbonate Recyclability: Contact WireByClick on 1300 546 449 for product take-back IMPORTANT - READ BEFORE INSTALLATION OR MODIFICATION REFER TO RELEVANT WBC INSTALLATION INSTRUCTIONS WireByClick SWA modules are used in conjunction with WireByClick 3-Pin and/or 5-Pin Installation Coupler System. Any installation using SWA modules must be in conjunction with relevant WireByClick 3-Pin or 5-Pin Installation Instructions. Please read these first before installation or modification of SWA Modules WIRING AND INSTALLATION OF SWA ADAPTER Installation and any wiring as outlined in this document to be performed by a qualified electrician in accordance to AS/NZS 3000 Wiring Rules UNUSED OUTLETS Any unused outlets are to be fitted with a dust cover (cat. no. DC20) to prevent ingress of dust and for increased protection WIRE STRIPPING & CABLE INSTALLATION TERMINAL COVER REMOVAL To remove cover, simply unscrew fixing screw. For configurations 2 and 3 detailed above, the break-out section of the terminal cover must be removed as shown on the right Tear break-out with pliers TERMINAL BLOCK WIRING Install suitable cable: Size range 2.5mm² – 4mm² cable. Stripping lengths shown on the right Always ensure conductors are fully inserted into terminal block before tightening terminal screws SCREW TIGHTENING TORQUES Terminal block screw torque: 1 Nm (min) Terminal Cover screw torque: 4 Nm (min) Wire strip 8mm Sheath strip = 25mm SWITCH ADAPTER CONFIGURATION WIRING In this configuration a twin switch cable is to be wired from a switch into the terminal block. providing switch control for Outlet 2. This configuration is typical for local control of small lighting circuits. Image to the rights shows correct Switch Adapter configuration wiring: LINE LOAD Terminal 1 is the Active Line from Outlet 1 Terminal 2 is the Active load to Outlet 2 Always ensure installed cable is securely pushed into locating ribs prior to re-installing terminal cover To Switch CONNECTION To connect SWA module, simply plug together ensuring side retaining clip is latched. You should hear an audible “Click” when module is correctly engaged DISCONNECTION Module disconnection MUST only be performed by qualified electricians and NEVER done so under load in accordance with AS/NZS 3000 and 61535.1. ALWAYS ISOLAE CIRCUIT PRIOR TO ANY WORKS. PRODUCT OVERVIEW Outlet 1 plugs directly into the main supply Outlet 2 can be wired and controlled in 2 possible configurations as required via the terminal block: 1. DOUBLE ADAPTER Outlet 2 directly connected to Outlet 1 (link to be wired between both terminals in terminal block) 2. SWITCH ADAPTER Outlet 2 active controlled by a remote switch (switch cable to be wired into module) Outlet 1 (main outlet) Outlet 2 Terminal Block Cover Supply outlet (3-Pin or 5-Pin) 1300 546 449 wirebyclick.com © 2012 WBC Group Pty Ltd All rights reserved rev01