SW USB Series USB Switchers Setup Guide The Extron SW2 USB, SW4 USB, and SW4 USB Plus are two- and four-input USB switchers that allow switching between multiple host devices and USB peripherals. They can be remotely set up and controlled via a host computer or other control system that is attached to the rear panel RS-232 port. Simple Instruction Set (SIS™) commands can be issued to the switcher from a computer using the RS-232 Interface. 6. If using RS-232 pass-through to control an A/V switcher, Follow these steps to set up and start using the SW USB. (Refer enter one of the following SIS commands via your to the SW USB Series User’s Manual for details.) computer’s RS-232 interface to select a loop mode. 1. Mount the SW USB on a rack shelf or under furniture, if • E 1LOOP} (Loop 1 mode) — SIS commands are desired. sent via an RS-232 interface to the SW USB, which 2. Connect host device(s) to one or more SW USB input passes them through the RS-232 Pass thru port to the connectors, using A to B type USB cable in lengths of up to A/V switcher. 15' (4.5 m). • E 0LOOP} (Loop 0 mode [default]) — In addition to 3. Connect one or more peripheral USB devices (such as a SIS commands being sent from the computer’s RS-232 keyboard and/or mouse) to the USB Output Hub ports, using interface to the A/V switcher via the RS-232 Pass Thru port, the SW USB sends the SIS input selection USB cable in lengths of up to 15' (4.5 m). command X! ! to the A/V switcher via the RS-232 Pass If host emulation will be used (SW USB Plus only): Attach Thru port, regardless of the method of input selection a standard keyboard and/or mouse to output port 3 and/or (contact closure, front panel button, or SIS command). 4, and set the appropriate DIP switch(es) to On. (If host 7. If desired, connect a 2-button or 4-button contact closure emulation is not used, connect devices to any desired port.) device to the SW USB’s Contact port. 4. If desired, connect an RS-232 cable to the SW USB’s RS-232 8. If using a different external power supply from the provided port and to a host computer or control system. one, wire the two-pin captive screw connector to the power N The RS-232 computer or control system should not supply. be one of the source devices connected to any of the 9. Power on the system components in the following order: input ports. a. USB peripheral device(s) 5. If desired, connect an external Extron A/V switcher to the b. The SW USB switcher RS-232 Pass Thru port. This switcher can then be controlled by commands sent via this port. c. The host device(s) Mouse Keyboard RS-232 Extron SW4 USB Plus 2 -23 RS TS PU B HU HOSTION AT UL EM B3 UT BO USB Switcher US B2 US US B4 MO ON E US ON Tx Rx 1 T AC NT CO 3 4 2 Tx 2 -23 RS THRU SS PA RD F OF YBOA KE US B1 US TS PU ED IN PC ITCH B SW US PC R WE PO X PC PC 4 3 RS-232 Control System + USB Ac Extron SW4 USB USB Switcher : eo Vid D l RE nne a Ch l nta rizo Ho c n Sy e ls Pu 2 USB OUT 1 USB UT RS-232 Loop-Through TP HU Tx US B3 B OU B2 US US Rx 1 CT NTA CO 3 4 2 Tx 232 U RS-THR S PAS US US OUT USB 101 Rx AUTOH SWITC 232 RS- B USB 01 AAP VTR0 AAP 102 USB B4 B1 T PU NG IN HI ITC B SW Desktop PC #4 US PC PC PC PC 4 3 2 1 ER POW 12V MAX 0.4A + Desktop PC #3 Desktop PC #1 o ide eV tiv 2 1 12V A MA 1.5 USB Interactive Whiteboard Desktop PC #2 VGA Outputs PC PC PC PC s A Ar 4 VG SW TE MO UT RE TP OU UT TP OU Extron SW4 VGA Ars VGA/Audio Switcher S UT R L Connection diagram for an SW4 USB switcher with an interactive white board 3 INP 1 4 2 0.2A 240V 100- 0Hz 50-6 Extron USA - West Flat Panel Display SW4 USB Plus switcher in a KVM (keyboard/video/mouse) switching application Headquarters +800.633.9876 Inside USA / Canada Only +1.714.491.1500 +1.714.491.1517 FAX Extron USA - East Extron Europe Extron Asia Extron Japan Extron China Extron Middle East +800.633.9876 +800.3987.6673 +800.7339.8766 +81.3.3511.7655 +81.3.3511.7656 FAX +400.883.1568 +971.4.2991800 +971.4.2991880 FAX +1.919.863.1794 +1.919.863.1797 FAX +31.33.453.4040 +31.33.453.4050 FAX +65.6383.4400 +65.6383.4664 FAX Inside USA / Canada Only Inside Europe Only Inside Asia Only Inside China Only +86.21.3760.1568 +86.21.3760.1566 FAX 68-1679-01 Rev. A 01 09