COMBINATION ON/OFF/DIMMING PHOTOCELL
CEILING MOUNT• LOW VOLTAGE
SPECIFICATIONS
DIMMING
OVERVIEW
OPTIONS
The nLight nCM ADC Series photocell
DUAL ZONE (DZ)
FEATURES
sensor provides both on/off and automatic
• Ideal for classrooms w/ individually
Automatically Dims 0-10 VDC Controlled dimming control for daylight harvesting
controlled parallel rows of light
LED Drivers or Fluorescent Ballasts
applications. Ideal for spaces with windows,
• Provides a second on/off output for
Full On/Off Switching of Lighting
such as vestibules, corridors, classrooms,
controlling a second relay
Communicates w/ nLight Network
or offices, the sensor works by monitoring
• Provides a second dimming output
Remotely Configurable/Upgradeable
daylight conditions in a room, then controlling
for controlling a second 0-10 VDC
Self-calibrating Set-Point
the lighting so as to ensure that adequate
dimmable ballast
Push-Button Programmable
• For on/off operation, sensor uses a
lighting levels are maintained. The nCM ADC
relative set-point for the second
100 Hr Lamp Burn-in Timer
is capable of directly controlling the dimming
pole that is a percentage of the first
Green LED Indicator
level of any 0-10 VDC dimmable ballast as well
pole’s set-point
as signaling a power pack or other relay to turn
PHYSICAL SPECS
• For dimming control, the second
off power completely. The nCM ADC sensor
SIZE: Circular 4.55” Dia. (11.56 cm)
zone’s 0-10 VDC dimmable ballast
can be used alone or together with occupancy
is controlled a selected level
1.55” Deep (3.94 cm)
sensors.
(voltage) higher than primary zone
WEIGHT: 6 oz
• Adds a third 20 AWG violet wire
MOUNTING:
SENSOR OPERATION
Ceiling Tile Surface
LOW TEMP/HIGH HUMIDITY (LT)
The sensor controls a 0-10 VDC dimmable
Round Fixture Box
• Sensor electronics are coated for
LED driver or fluorescent ballast to achieve
Single Gang Handy Box
corrosion resistance
maximum
daylight
harvesting
while
• Operates down to -40º F/C
COLOR: White
maintaining a minimum light level referred to
nLIGHT NETWORK PORTS: 2 RJ-45
as the set-point. When no daylight is available,
ELECTRICAL SPECS
the sensor allows the dimmable driver/ballast
POWER CONSUMPTION: < 3 mA
to operate at its full bright level (10 VDC). As daylight increases and begins to contribute to the
DIMMING LOAD: Sinks < 20mA
overall light level of the room, the Automatic Dimming Control (ADC) feature starts dimming
(0-10 VDC LED Drivers / Ballasts
the ballast proportionally. When sufficient daylight is present to maintain the set-point without
WIRES 20 AWG (2)
any contribution from the lights, a relay located elsewhere within the sensor’s zone is signaled
to switch the line voltage lighting load off completely.
ENVIRONMENTAL SPECS
OPERATING TEMP:
The lights will remain off until the daylight level
14º to 160º F (-10º to 71º C)
AMPLE DAYLIGHT
drops below the set-point. At this point, the
RELATIVE HUMIDITY:
lights will be turned on with the driver/ballast
20 to 90% non-condensing
set at its full dim level. As the daylight levels
SILICONE FREE
fall further, the ADC feature will again take
ROHS COMPLIANT
control; reducing the dim level (increasing the
OTHER
brightness) in order to achieve the necessary
UL and CUL Listed
light level. At the point when all daylight
Title 24 Compliant
contribution is gone, the lighting will be back
Set-point
5 Year Warranty
at its full bright level. To make the series of
Assembled in the U.S.A.
adjustments unnoticeable to room occupants,
a 10 to 20% safety factor is maintained to
prevent the system from cycling when the light
NO DAYLIGHT
level is very near the set-point. There is also a
Lights Turn OFF
Lights Turn ON
user selectable 45 second to 25 minute delay
before the sensor transitions the lights on or off
ON/OFF & DIMMING
prevents the system from cycling.
ORDERING INFO
nCM ADC [DUAL ZONE] [TEMP/HUMIDITY]
OPTIONS
TEMP/HUMIDITY
Blank = None
DZ = Dual Zone
Blank = Standard
LT = Low Temp
DUAL ZONE
Revised 07.22.13 © 2013 Sensor Switch
WIRING (DO NOT WIRE HOT)
Sensor power is provided via the CAT-5e connection. T568B pin/pair assignment is recommended for all CAT-5e cables.
CAT-5e
BLK - 120 V
ORN - 277 V
nPP16
CAT-5e
VIO
GRY
0-10 VDC
BALLAST/LED DRIVER
GRN
VIO/WHT STRIPED
[DZ] Dual Zone
nLIGHT OPERATION
This sensor is a native nLight device, meaning it has the ability to communicate over an nLight network. When connected, using CAT-5e
cabling, with other nLight sensors, power packs, or WallPods, an nLight control zone is created. Once linked to a Gateway, directly or via a
Bridge, the zone becomes capable of remote status monitoring and control via SensorView software.
DEVICE SETTINGS
Several operational settings for the nCM ADC are available:
• Automatic set-point calibration mode
• Dual zone set-point offpoint % (110-200%)
• 100 hr burn-in timer mode
• Dual zone dimming offset (.5-10 VDC)
• Blink back set-point (in footcandles)
• Photocell transistion off timer (45 sec to 25 min)
• 10’s digit of set-point (0-200 fc)
• Photocell transistion on timer (45 sec to 25 min)
• One’s digit of set-point (0-9 fc)
• Photocell broadcasting (enable/disable)
• Dimming range upper limit (0-10 VDC)
• Photocell broadcast channel (1-16)
• Dimming range lower limit (0-10 VDC)
• Sunlight discount factor (1-8)
INSTALLATION
PUSH-BUTTON
RJ-45 PORTS
• Mount sensor directly to a ceiling tile or a metallic grid (two selftapping screws provided)
• Sensor’s mounting holes also align with standard round fixture or
single gang handy box (screws not provided)
• Interconnect unit (via RJ-45 ports) with other nLight devices in
lighting zone using CAT-5e cables
• Once power is received via CAT-5e connection, all devices in zone
will automatically begin functioning together according to each
device’s defaults
PROGRAMMING
Refer to included instruction card for default settings and directions on programming the sensor via the push-button.
WARRANTY: Sensor Switch warrants these products to be free of defects in manufacture and workmanship for a
period of 60 months. Sensor Switch, upon prompt notice of such defect, will, at its option, provide a Returned Material
Authorization number and repair or replace returned product.
LIMITATIONS AND EXCLUSIONS: This Warranty is in full lieu of all other representation and expressed and implied
warranties (including the implied warranties of merchantability and fitness for use) and under no circumstances shall
Sensor Switch be liable for any incidental or consequential property damages or losses.
TN-112-02
900 Northrop Road, Wallingford, CT 06492 • 1.800.PASSIVE • FX 203.269.9621 • www.sensorswitch.com
Download