nCM-PC ON/OFF PHOTOCELL CEILING MOUNT• LOW VOLTAGE SPECIFICATIONS Features Full On/Off Switching Control Communicates w/ nLight Network Remotely Configurable/Upgradeable Self-Calibrating Set-Point Push-Button Programmable 100 Hr Lamp Burn-in Timer Green LED Indicator physical specs SIZE Circular 4.55” Dia. (11.56 cm) 1.55” Deep (3.94 cm) WEIGHT 6 oz MOUNTING Ceiling Tile Surface Round Fixture Box Single Gang Handy Box COLOR White NETWORK CONNECTION 2 RJ-45 Ports electrical specs POWER CONSUMPTION < 2 mA WIRES None environmental specs OPERATING TEMP 14º to 160º F (-10º to 71º C) STORAGE TEMP -14º to 160º F (-26º to 71º C) RELATIVE HUMIDITY 20 to 90% non-condensing Other UL and CUL Listed Title 24 Compliant 5 Year Warranty Made in the U.S.A. The nCM-PC Series On/Off Photocell sensor provides the industry’s most intelligent control of lighting for daylight harvesting applications. Ideal for public spaces with windows like vestibules, corridors, or bathrooms; the sensor works by monitoring daylight conditions in a room, then controlling the lighting so as to insure that an adequate lighting level is maintained. The nCM-PC is used for on/ off lighting control; turning off the lights when sufficient natural light is present and turning them on when additional lighting is necessary. The nCM-PC sensor can be used alone or together with occupancy sensors. To add dimming control to the on/off switching provided by the nCM-PC, see the nCM-PC-ADC sensor. SENSOR OPERATION OPTIONS Dual zone (-DZ) • Provides second output that can control an additional zone of lighting stepped dimming (duo) • Ideal for A/B switching applications • Determines the necessary on/off combination of the two poles in order to maintain adequate lighting percentage offset operation • Ideal for classrooms with individually controlled parallel rows of lights • On/OffOperation: Full control during periods of occupancy with adequate daylight • Second zones uses a relative setpoint that is a percentage of the first zones’s set-point LOW TEMP/HIGH HUMIDITY (-LT) When the space’s overall light level drops • Sensor is corrosion resistant to below a programmable threshold called moisture a set-point, the sensor signals a relay • Operates down to -40º F/C located elsewhere within the sensor’s zone to switch the line voltage lighting load on. The lights turn off when light is above the set-point plus a 10 to 20% safety factor and deadband. The safety factor will prevent the system from cycling when the light level is very near the set-point. The deadband is the level of light contributed by the artificial lights being controlled. This level is tracked so if the lighting conditions change (for example a lamp burns out) the point at which the lights turn off is adapted accordingly. If the photocell is looking up at skylights and can not view the lights being controlled, there is no deadband and the sensor is said to be working open loop. There is also an adaptive cloud delay (optional) before the photocell turns the lights off to prevent the system AMPLE DAYLIGHT from cycling on a cloudy day. nLIGHT OPERATION DEADBAND Set-point NO DAYLIGHT Lights Turn ON Lights Turn OFF This sensor is nLight-enabled, meaning it has the ability to communicate over an nLight network. When daisy-chain wired, using CAT-5 cabling, with other nLight-enabled sensors, power packs, or WallPods, an nLight control zone is created. Once linked to a Gateway, directly or via a Bridge, the zone becomes capable of remote status monitoring and control via SensorView software. ORDERING INFO nCM-PC-[DUAL ZONE]-[TEMP/HUMIDITY] OPTIONS TEMP/Humidity Blank = None -DZ = Dual Zone Blank = Standard -LT = Low Temp Dual zone Revised 07.07.08 © 2008 Sensor Switch, Inc. WIRING (DO NOT WIRE HOT) Note: Sensor power is provided via the CAT-5 connection. BLK - 120 V ORN - 277 V nPP-16 CAT-5 LOAD CAT-5 DEVICE SETTINGS Several operational settings for the nCM-PC are available: • Automatic set-point calibration mode • Photocell broadcast channel (1-16) • 100 hr burn-in timer mode (enable/disable) • Photocell Mode Selection: • Blink back set-point (in footcandles) • 10’s digit of set-point (0-200 fc) Stepped Dimming Stepped Dimming w/ one pole always left on Dual Zone Mode - Percentage offset between zones Fan Mode - Zone 2’s photocell control is disabled • One’s digit of set-point (0-9 fc) • Dual zone set-point offpoint % (110-200%) • Sunlight discount factor (1-8) • Photocell transistion off timer (45 sec to 25 min) • Photocell broadcasting (enable/disable) • Photocell transistion on timer (45 sec to 25 min) INSTALLATION • Mount sensor directly to a ceiling tile or a metallic grid (two self-tapping screws provided) • Sensor’s mounting holes also align with standard round fixture or single gang handy box (screws not provided) • Interconnect unit (via RJ-45 ports) with other nLight devices in lighting zone using CAT-5 cables • Once power is received via CAT-5 connection, all devices in zone will automatically begin functioning together according to each device’s defaults PUSH-BUTTON RJ-45 PORTS PROGRAMMING Refer to included instruction card for default settings and directions on programming the sensor via the push-button. ® WARRANTY: Sensor Switch, Inc. warrants these products to be free of defects in manufacture and workmanship for a period of 60 months. Sensor Switch, Inc., upon prompt notice of such defect, will, at its option, provide a Returned Material Authorization number and repair or replace returned product. Limitations and Exclusions: This Warranty is in full lieu of all other representation and expressed and implied warranties (including the implied warranties of merchantability and fitness for use) and under no circumstances shall Sensor Switch, Inc. be liable for any incidental or consequential property damages or losses. TN-111-01 900 Northrop Road, Wallingford, CT 06492 • 1.800.PASSIVE • FX 203.269.9621 • www.sensorswitch.com