nCM ADC / nCM ADCX AUTOMATIC DIMMING PHOTOCELL CEILING MOUNT • LOW VOLTAGE SPECIFICATIONS FEATURES Automatically Dims Lighting via Remote or Local Dimming Output(s) Full On/Off Switching of Lighting Communicates w/ nLight Network Remotely Configurable/Upgradeable Self-calibrating Set-Point Push-Button Programmable 100 Hr Lamp Burn-in Timer Green LED Indicator PHYSICAL SPECS SIZE: Circular 4.55” Dia. (11.56 cm) 1.55” Deep (3.94 cm) WEIGHT: 6 oz MOUNTING: Ceiling Tile Surface Round Fixture Box Single Gang Handy Box COLOR: White nLIGHT NETWORK PORTS: 2 RJ-45 ELECTRICAL SPECS POWER CONSUMPTION: < 3 mA DIMMING LOAD of LOCAL OUTPUT(s): Sinks < 20mA; 0-10 VDC LED Drivers / Fluorescent Ballasts WIRES: nCM ADCX - None nCM ADC - 20 AWG (2), 18 AWG (1) OTHER UL and CUL Listed Title 24 System Component 5 Year Warranty Assembled in the U.S.A. The nCM ADCX communicates with remote nLight switching and/or dimming devices (e.g. nIO D, nIO LEDG, nIO EZ, nPP16 D, and nPANEL) to automatically adjust a zones lighting levels. The nCM ADC can communicate with remote devices as well as control the dimming level of any directly wired 0-10 VDC dimmable driver or ballast through its integrated output. The nCM ADC(X) can be used alone in a zone or together with occupancy sensors. OPTIONS DUAL ZONE (DZ) • Ideal for classrooms w/ individually controlled parallel rows of light • Controls a second remote relay or dimming output • For on/off operation, sensor uses a relative set-point for the second pole that is a percentage of the first pole’s set-point • For dimming control, the second zone’s dimming output is controlled a selected percentage higher than the primary output [Note: if controlling remote dimming output devices, dimming offsets can also be achieved via each device’s “SECONDARY DIMMING (DUAL) ZONE OFFSET” setting] • ADC DZ version adds a second integrated 0-10 VDC dimming output (20 AWG violet/white striped wire) SENSOR OPERATION LOW TEMP/HIGH HUMIDITY (LT) The sensor controls a zones lighting to achieve • Sensor electronics are coated for maximum daylight harvesting while maintaining corrosion resistance a minimum light level referred to as the set• Operates down to -40º F/C point. When no daylight is available, the sensor allows dimming outputs to operate at their full bright level. As daylight increases and begins to contribute to the overall light level of the room, the sensor starts dimming the controlled lights proportionally. When sufficient daylight is present to maintain the set-point without any contribution from the lights, a relay located elsewhere within the sensor’s zone is signaled to switch the line voltage lighting load off AMPLE DAYLIGHT completely. The lights will remain off until the daylight level drops below the set-point. At this point, the lights will be turned on with dimming outputs at their full dim level. As the daylight levels fall further, the sensor will reduce the dim level (increasing the brightness) in order to achieve the necessary light level. At the point when all daylight contribution is gone, the lighting will be back at its full bright level. To make the series of adjustments unnoticeable to room occupants, a 10 to 20% safety factor is maintained to prevent the system from cycling when the light level is very near the set-point. There is also a user selectable 45 second to 25 minute delay before the sensor transitions the lights on or off prevents the system from cycling. DIMMING ENVIRONMENTAL SPECS OPERATING TEMP: 14º to 160º F (-10º to 71º C) RELATIVE HUMIDITY: 20 to 90% non-condensing SILICONE FREE ROHS COMPLIANT OVERVIEW The nLight nCM ADC(X) Series photocell sensor provides both on/off and automatic dimming control for daylight harvesting applications. Ideal for spaces with windows, such as vestibules, corridors, classrooms, or offices, the sensor works by monitoring daylight conditions in a room, then controlling the lighting so as to ensure that adequate lighting levels are maintained. Set-point NO DAYLIGHT Lights Turn ON Lights Turn OFF ON/OFF & DIMMING ORDERING INFO nCM [DAYLIGHTING] [DUAL ZONE] [TEMP/HUMIDITY] OPTIONS DAYLIGHTING DUAL ZONE ADC = Auto Dimming Control Photocell (with 0-10 VDC wires) ADCX = Auto Dimming Control Photocell (no wires) Blank = None DZ = Dual Zone1 TEMP/HUMIDITY Blank = Standard LT = Low Temp 1. Not available with ADCX option. Dual zone operation can be achieved via the networked devices with dimming outputs. Revised 09.30.14 © 2014 Sensor Switch WIRING (DO NOT WIRE HOT) T568B pin/pair assignment is recommended for all CAT-5e cables. Sensor power is provided via the CAT-5e connection to an nLight power pack/supply, nLight-enabled digital luminaire, or nLight Bridge. nCM ADCX nCM ADC CAT-5e BLK - 120 V ORN - 277 V nPP16 CAT-5e CAT-5e nPP16 BLK - 120 V ORN - 277 V LOAD VIO (Dim Output) CAT-5e LOAD GRY (Common) GRN * VIO/WHT STRIPED [DZ] Dual Zone dimming output *Note: A green wire is available for an optional connection to an approved ground. This wire is isolated from the class 2 circuitry of the sensor. Connection will provide improved network protection in case of accidental landing of line voltage to VIOLET or GRAY dimming wires. If an approved ground is not available the green wire should be capped. nLIGHT OPERATION This sensor is a native nLight device, meaning it has the ability to communicate over an nLight network. When connected, using CAT-5e cabling, with other nLight sensors, power packs, or WallPods, an nLight control zone is created. Once linked to a Gateway, directly or via a Bridge, the zone becomes capable of remote status monitoring and control via SensorView software. DEVICE SETTINGS Several operational settings for the nCM ADC(X) are available: • Automatic set-point calibration mode • Dual zone set-point offpoint % (110-200%) • 100 hr burn-in timer mode • Dual zone dimming offset (.5-10 VDC) • Blink back set-point (in footcandles) • Photocell transistion off timer (45 sec to 25 min) • 10’s digit of set-point (0-200 fc) • Photocell transistion on timer (45 sec to 25 min) • One’s digit of set-point (0-9 fc) • Photocell broadcasting (enable/disable) • Dimming range upper limit (0-10 VDC) • Photocell broadcast channel (1-16) • Dimming range lower limit (0-10 VDC) • Sunlight discount factor (1-8) INSTALLATION PUSH-BUTTON RJ-45 PORTS • Mount sensor directly to a ceiling tile or a metallic grid (two selftapping screws provided) • Sensor’s mounting holes also align with standard round fixture or single gang handy box (screws not provided) • Interconnect unit (via RJ-45 ports) with other nLight devices in lighting zone using CAT-5e cables • Once power is received via CAT-5e connection, all devices in zone will automatically begin functioning together according to each device’s defaults PROGRAMMING Refer to included instruction card for default settings and directions on programming the sensor via the push-button. WARRANTY: Sensor Switch warrants these products to be free of defects in manufacture and workmanship for a period of 60 months. Sensor Switch, upon prompt notice of such defect, will, at its option, provide a Returned Material Authorization number and repair or replace returned product. LIMITATIONS AND EXCLUSIONS: This Warranty is in full lieu of all other representation and expressed and implied warranties (including the implied warranties of merchantability and fitness for use) and under no circumstances shall Sensor Switch be liable for any incidental or consequential property damages or losses. TN-110-05 900 Northrop Road, Wallingford, CT 06492 • 1.800.PASSIVE • sensorswitch.com