KEWAUNEE ® ScientificCorporation H08 Supreme Air Fume Hood ADA Bench Hood with Vertical Rising Sash (indicate fittings/fixtures required) (indicate fittings/fixtures required) [Alarm Location 1] NOTE: ADA Hoods Require W-4285 Ball Valve Fittings 120VAC GFI Duplex Gravity Sash Stop @14" above deflector vane Plugged [Cold Water] [Air] Plugged Plugged [Vacuum] [Gas] Plugged Lt. Switch /120VAC GFI Receptacle [Fan Switch] Blank Face Plate Liner Option: (pick one only) qK qG qS qT By-Pass Option: (pick one only) ADA guidelines require 30" minimum for wheelchair access KMER Kemglass Type 304 St. Steel Phenolic Resin q - Open By-Pass q B Restricted By-Pass (restricted to 20% of face opening) (front panel louvers omitted) Length: (pick one only) q 48" q 60" q 72" Pre-piping: (pick one if required) q Pre-pipe Up q Pre-pipe Down Add On Options: (indicate options required) Interior Baffle Arrangement Options: (pick one only) Sash Handle Options: (pick one only) Standard Fixed Baffle qA Adjustable Baffle qC Single-Point Adjustable Baffles Standard Painted Metal Sash Handle qQ Stainless Steel Sash Handle Distillation Rack Option: (pick if required) qD Distillation Rack Fire Extinguisher Option: (pick if required) qE Fire Extinguisher Electric and Plumbing Options: (pick all required) qH Pre-Wired to Top of Hood Safety Shield Option: (pick if required) qI Safety Shield Interior Lighting Options: (pick one only) Standard qJ qK qL Fluorescent Light (T-5 Ballast) Fluorescent Light (T-8 Ballast) Vapor Proof Light (Incandescent) Explosion Proof Light (Incandescent) Lower Deflector Vane Options: (pick one only) Standard Painted Lower Deflector Vane qO Stainless Steel Deflector Vane Top Front Panel Options: (pick one only) qT Chevron Grille (Open By-Pass Only) qV Vision Panel Fume Hood Alarm Options: (pick one if required) qW Air Alert 300 Alarm (location 1) qM Air Alert 600 Alarm (location 1) Sash Frame and Glass Options: (pick one only) Standard q1 q2 q3 q4 q5 Frameless Laminated Safety Glass Sash Frameless Tempered Glass Sash Framed Laminated Safety Glass Sash Framed Tempered Glass Sash Stainless Steel Safety Glass Sash Stainless Steel Tempered Glass Sash Miscellaneous Options: (pick all required) q6 q7 q8 Tissue Screen Stainless Steel Duct Collar Move Gravity Sash Stop (from 14" above deflector to 18" above deflector ) LINER H08 54 PROJECT NAME: 10/13 LENGTH BY-PASS ADD-ON OPTIONS COLOR ITEM NO. 00__________________ QUANTITY page 1 of 2 KEWAUNEE ® ScientificCorporation H08 Supreme Air Fume Hood ADA Bench Hood with Vertical Rising Sash Plan of Work Top Indicate cutouts required by noting cupsink part number or size and/or hole type and size at desired location: Alternate Cupsink Location Example: Alternate Cupsink Location The example below calls for two 491 cupsink cutouts in the front. 31" Standard ADA Cupsink Location Alternate Cupsink Location Alternate Cupsink Location Alternate Cupsink Location Stanard Alternate Cupsink Location ADA Cupsink 491Location 491 47 3/4 " – 59 3/4 " – 71 3/4 " For sink or steambath cutout: Sketch in size and location required. Work Top Material q Black Kemresin q Type 304 Stainless Steel q Type 316 Stainless Steel If no cutout is marked, work top will ship with 3"x6" cupsink cutout in left front corner. If no cutout is required, cross out standard cupsink location. (Cupsink is welded in stainless steel work tops.) Overall Hood Length 4'-0" / 48" 5'-0" / 60" 6'-0" / 72" Width 40" 52" 64" Sash Opening Height Total Ft.2 14" 4.7 14" 6.1 14" 7.6 * Total CFM and Static Pressure S.P. 100 FPM S.P. 120 FPM 0.05" 470 0.10" 570 0.10" 610 0.10" 740 0.10" 760 0.15" 910 80 FPM 380 490 600 S.P. 0.15" 0.15" 0.20" * Includes By-Pass opening. • CFM requirements shown above are for Open By-Pass hoods with sash stop at 14". CFM requirements for sash fully open are same as H05. • Static pressures shown are for the pressure drop through the hoods only. The total pressure drop through the hood and the duct system must be calculated to select the proper exhaust fan. Rough-In for 4' – 5' – 6' Hoods Vertical Section Pipe Space Below Work Top Plumbing Access (both sides) EQ 36" EQ 8" 2" 9 1/2" 1" 1 1/2 " 7" 20 1/2" 22" 36" Rough-in may vary depending on hood base unit locations. Contact your Kewaunee sales representative for more information. 54" 86 3/4 " 29" Sash Opening 14" to Sash Stop 48"– 60"– 72" 93 3/4 " Clearance – Sash Up 11 15/16 " O.D. Exhaust Collar 5" 5" 71" 25 1/2 " 5" 1 1/4 " 34" (max) ADA guidelines require 30" minimum for wheelchair clearance. 22" page 2 of 2 8" 10/13