ID 932 Product Report Card Manufacturer: Lighting Science (EcoSmart) Model Number Tested: ECS GP19 WW 40WE 120 DFN GP19 40WE NW 120, DFN GP19 40WE W27 120, DFN GP19 40WE WW 120, DFN GP19 40WE CW Other Model Numbers: 120 Manufacturer's Description Type of device: Operating voltage: Input Power Input Current: Input Frequency: LED Snowcone - 40W Equivalent 120V 6.0 W 0.05 A 60Hz Lutron Test Results Date Tested: Test Voltage: Test Notes: 21-Feb-13 120 V None Control Type: Dimming Range: Output Power: Lumen Output: Forward Phase (including MLV) Not Specified Not Specified 450 Lutron Recommended Compatible Products Lutron products not in this list can be considered to be not recommended, based on our testing. Product Model Number Fixtures per Dimmer Minimum Maximum Measured Dimming Range (1) Low End High End Perceived Low End(2) Comments Wallbox Dimmers No applicable results Commercial Systems Stanza Panel Module SZ-6ND HW/LP-RPM4A-120 1 1 18 37 9% 10% 96% 100% 31% 31% HW/LP-RPM4U-120 Grafik Eye QS Main Unit Family GP (Harrier) Card 1 60 10% 100% 31% 1 25 10% 100% 32% 1 60 10% 99% 32% RRD-10ND HQRD-10ND RRD-6NA 1 1 1 25 25 25 18% 18% 18% 96% 96% 96% 43% 43% 42% Homeworks QS HQRD-6NA 1 25 18% 96% 42% HomeWorks Panel Module HxD-6ND HW/LP-RPM4A-120 1 1 18 37 9% 10% 96% 100% 31% 31% Panel Module HW/LP-RPM4U-120 Grafik Eye QS Main Unit Family GP (Harrier) Card 1 60 10% 100% 31% 1 25 10% 100% 32% 1 60 10% 99% 32% Panel Module Grafik QS Panel Module Residential Systems RadioRA 2 HomeWorks QS RadioRA 2 Grafik QS Panel Module High end trim required. Set load type to FP. Rating is per channel; total per module is 59. Rating is per channel; total per module is 60. High end trim required. Rating is per output; total per Main Unit is 62. Rating is per output. Load type not slectable. Evaluated in FP. Load type not slectable. Evaluated in FP. High end trim required. Set load type to FP. Rating is per channel; total per module is 59. Rating is per channel; total per module is 60. High end trim required. Rating is per output; total per Main Unit is 62. Rating is per output. Interfaces (3) No applicable results Notes: (1) Values are based on light output using the specified dimming control, and may not be an indication of the fixture’s full rated capability (2) Perceived light level percentage is the square root of the measured light level percentage, per IESNA Lighting Handbook (3) Interfaces have been tested with the listed control; any compatible dimmer may be used instead, but high end/low end light levels may vary slightly Page 1 of 2 Test Comments: Performance verified with up to 25 fixtures per control. Maximum Fixtures per Dimmer value represents the maximum safe loading of the control. Low end trim required. For any questions on this report, please contact the Lutron LED Center of Excellence at 877-DIM-LED8 or leds@lutron.com. This information was posted with the consent and cooperation of the device manufacturer. Latest test results can always be found at www.lutron.com/LEDtool. Page 2 of 2