ID 1980 Product Report Card Manufacturer: Model Number Tested: Other Model Numbers: Manufacturer's Description Type of device: Operating voltage: Input Power Input Current: Input Frequency: Lutron Test Results Date Tested: Test Voltage: Test Notes: Cooper SLD612830WHUNVJB SLD612827WHUNVJB, SLD612830WHUNVJB, SLD612835WHUNVJB, SLD612840WHUNVJB, SLD612927WHUNVJB, SLD612930WHUNVJB, SLD612935WHUNVJB, SLD612940WHUNVJB LED 14.8 W Downlight 120V/277V 14.8 W 0.04 A 60 Hz/50 Hz Control Type: Dimming Range: Output Power: Lumen Output: Type/Shape: Base Type: Forward and Reverse Phase Control Not Specified Not Specified 1200 lm Downlight E26 29-Oct-15 120 V Performance verified with up to 10 fixtures per control. Test results valid only at 120 V and 60 Hz. Test results valid only with a Cooper ESS015W-0350-42-CPLV driver. Lutron Recommended Products Lutron products not in this list can be considered to be not recommended, based on our testing. Model Number Control Fixtures per Measured Dimming Range (3) Product (1) (2) (Software Trim Settings) Dimmer Type Min-Max Low End High End Wallbox Dimmers Maestro Maestro Wireless Maestro Sensor Caseta Wireless Maestro Wireless Commercial Systems Stanza Panel Module Panel Module Grafik QS/ Wallbox Power Module Panel Module Grafik Eye 3000/ HomeWorks HomeWorksQS/ myRoom Perceived Comments (4) Low End MACL-153M (_)* FP 1 - 10 8% 99% 29% MRF2-6ELV MSCL-OP153M (T2)*/ MSCL-VP153M (T2)* PD-6WCL (SD11)* MRF2-6CL (M6)* RP FP 1 - 10 1 - 10 8% 13% 100% 99% 29% 36% FP 1 - 10 17% 100% 42% FP 1 - 10 17% 100% 41% SZ-6ND HW/LP-RPM-4A120 FP RP 1-6 1 - 44 9% (10) 12% (12) 100% (88) 100% (75) 29% 34% HW/LP-RPM-4U120 Grafik Eye QS Main Unit Family/ LQRJ-WPM-6P GP (Harrier) Card Grafik Eye 3000 Family/ HWI-WPM-6D120 LQSE-4A1-D/ MQSE-4A1-D/ MQSE-3A1/ MQSE-2A1-D, 120V FP 1 - 30 12% (17) 100% (73) 35% FP 1 - 30 8% (12) 100% (72) 28% FP 1 - 30 10% (13) 99% (75) 32% FP 1 - 30 8% (12) 100% (72) 28% RP 1-6 9% (12) 99% (75) 30% Load type not selectable. High end trim required. Rating is per channel; total per module is 70. Rating is per channel; total per module is 30. Rating is per output; total quantity per Main Unit is 75. Rating is per output. Use load type 2-1. Rating is per output; total quantity per Main Unit is 45/56/75/75 for 2/3/4/6-Zone units, respectively. Rating is per output; total quantity per Main Unit is 24. Residential Systems Page 1 of 2 RadioRA 2 HomeWorks QS RadioRA 2 HomeWorks QS HomeWorks Panel Module RRD-10ND HQRD-10ND RRD-6NA HQRD-6NA HxD-6ND HW/LP-RPM-4A120 FP FP RP RP FP RP 1 - 10 1 - 10 1 - 10 1 - 10 1-6 1 - 44 9% (13) 9% (13) 8% (14) 8% (14) 9% (10) 12% (12) 100% (99) 100% (99) 100% (99) 100% (99) 100% (88) 100% (75) 30% 30% 29% 29% 29% 34% Panel Module HW/LP-RPM-4U120 Grafik Eye QS Main Unit Family/ LQRJ-WPM-6P GP (Harrier) Card Grafik Eye 3000 Family/ HWI-WPM-6D120 RRD-6CL (R3)* HQRD-6CL (H2)*/ HQRA-6CL (H2)* FP 1 - 30 12% (17) 100% (73) 35% FP 1 - 30 8% (12) 100% (72) 28% FP 1 - 30 10% (13) 99% (75) 32% FP 1 - 30 8% (12) 100% (72) 28% FP FP 1 - 10 1 - 10 17% (29) 17% (29) 100% (99) 100% (99) 41% 41% FP 1-6 5% (15) 100% (99) 22% FP 1-6 5% (15) 100% (99) 22% RP 1-6 9% (12) 99% (75) 30% RP 1 - 44 8% (15) 100% (73) 28% High end trim required. RP 1 - 44 8% 100% 28% High end trim required. Grafik QS/ Wallbox Power Module Panel Module Grafik Eye 3000/ HomeWorks RadioRA 2 HomeWorks QS RadioRA 2 HomeWorks QS HomeWorksQS/ myRoom RRD-H6BRL (with neutral) HQRD-H6BRL (with neutral) LQSE-4A1-D/ MQSE-4A1-D/ MQSE-3A1/ MQSE-2A1-D, 120V High end trim required. Rating is per channel; total per module is 70. Rating is per channel; total per module is 30. Rating is per output; total quantity per Main Unit is 75. Rating is per output. Use load type 2-1. Rating is per output; total quantity per Main Unit is 45/56/75/75 for 2/3/4/6-Zone units, respectively. Installation with a neutral wire is required. Installation with a neutral wire is required. Rating is per output; total quantity per Main Unit is 24. Interfaces (5) PHPM-PA with Grafik Eye QS Main Unit PHPM-WBX with 3-wire fluorescent control Notes: * Identical model numbers with different compatibility codes may have different performance; (_) means there is no compatibility code assigned; contact technical support for additional information. (1) Control types of FP and RP represent Forward Phase and Reverse Phase, respectively. See product literature for details. (2) Maximum Fixtures per Dimmer value represents the maximum safe loading of the control. (3) Values are based on light output using the specified dimming control, and may not be an indication of the fixture’s full rated capability. Values are set to optimize performance, such as reducing dead travel, ensuring that fixtures turn on at low end, reducing turn-on time at low end, and trimming out instability. Software trim values are indicated in parentheses when applicable. (4) Perceived light level percentage is the square root of the measured light level percentage, per IESNA Lighting Handbook. (5) Interfaces have been tested with the listed control; any compatible dimmer may be used instead, but high end/low end light levels may vary slightly. Test Comments: Performance verified with up to 10 fixtures per control. For any questions on this report, please contact the Lutron LED Center of Excellence at 877-DIM-LED8 or leds@lutron.com. This information was posted with the consent and cooperation of the device manufacturer. Please be aware that device manufacturers may modify their product at any time, without notice to Lutron, and therefore Lutron cannot ensure future compatibility. For more detailed and up to date fixture specifications, performance and/or any related recall information, visit the manufacturer’s website. The latest Lutron test results can always be found at www.lutron.com/LEDtool. Page 2 of 2