Cooper-Halo 1980 Downlight SLD612830WHUNVJB 14.8

advertisement
ID 1980
Product Report Card
Manufacturer:
Model Number Tested:
Other Model Numbers:
Manufacturer's Description
Type of device:
Operating voltage:
Input Power
Input Current:
Input Frequency:
Lutron Test Results
Date Tested:
Test Voltage:
Test Notes:
Cooper
SLD612830WHUNVJB
SLD612827WHUNVJB, SLD612830WHUNVJB, SLD612835WHUNVJB, SLD612840WHUNVJB,
SLD612927WHUNVJB, SLD612930WHUNVJB, SLD612935WHUNVJB, SLD612940WHUNVJB
LED 14.8 W Downlight
120V/277V
14.8 W
0.04 A
60 Hz/50 Hz
Control Type:
Dimming Range:
Output Power:
Lumen Output:
Type/Shape:
Base Type:
Forward and Reverse Phase Control
Not Specified
Not Specified
1200 lm
Downlight
E26
29-Oct-15
120 V
Performance verified with up to 10 fixtures per control. Test results valid only at 120 V and 60 Hz. Test results valid only
with a Cooper ESS015W-0350-42-CPLV driver.
Lutron Recommended Products
Lutron products not in this list can be considered to be not recommended, based on our testing.
Model Number Control Fixtures per Measured Dimming Range (3)
Product
(1)
(2)
(Software Trim Settings)
Dimmer
Type
Min-Max
Low End
High End
Wallbox Dimmers
Maestro
Maestro Wireless
Maestro Sensor
Caseta Wireless
Maestro Wireless
Commercial Systems
Stanza
Panel Module
Panel Module
Grafik QS/
Wallbox Power Module
Panel Module
Grafik Eye 3000/
HomeWorks
HomeWorksQS/
myRoom
Perceived Comments
(4)
Low End
MACL-153M (_)*
FP
1 - 10
8%
99%
29%
MRF2-6ELV
MSCL-OP153M
(T2)*/
MSCL-VP153M
(T2)*
PD-6WCL
(SD11)*
MRF2-6CL (M6)*
RP
FP
1 - 10
1 - 10
8%
13%
100%
99%
29%
36%
FP
1 - 10
17%
100%
42%
FP
1 - 10
17%
100%
41%
SZ-6ND
HW/LP-RPM-4A120
FP
RP
1-6
1 - 44
9% (10)
12% (12)
100% (88)
100% (75)
29%
34%
HW/LP-RPM-4U120
Grafik Eye QS
Main Unit
Family/
LQRJ-WPM-6P
GP (Harrier)
Card
Grafik Eye 3000
Family/
HWI-WPM-6D120
LQSE-4A1-D/
MQSE-4A1-D/
MQSE-3A1/
MQSE-2A1-D,
120V
FP
1 - 30
12% (17)
100% (73)
35%
FP
1 - 30
8% (12)
100% (72)
28%
FP
1 - 30
10% (13)
99% (75)
32%
FP
1 - 30
8% (12)
100% (72)
28%
RP
1-6
9% (12)
99% (75)
30%
Load type not selectable.
High end trim required. Rating
is per channel; total per module
is 70.
Rating is per channel; total per
module is 30.
Rating is per output; total
quantity per Main Unit is 75.
Rating is per output. Use load
type 2-1.
Rating is per output; total
quantity per Main Unit is
45/56/75/75 for 2/3/4/6-Zone
units, respectively.
Rating is per output; total
quantity per Main Unit is 24.
Residential Systems
Page 1 of 2
RadioRA 2
HomeWorks QS
RadioRA 2
HomeWorks QS
HomeWorks
Panel Module
RRD-10ND
HQRD-10ND
RRD-6NA
HQRD-6NA
HxD-6ND
HW/LP-RPM-4A120
FP
FP
RP
RP
FP
RP
1 - 10
1 - 10
1 - 10
1 - 10
1-6
1 - 44
9% (13)
9% (13)
8% (14)
8% (14)
9% (10)
12% (12)
100% (99)
100% (99)
100% (99)
100% (99)
100% (88)
100% (75)
30%
30%
29%
29%
29%
34%
Panel Module
HW/LP-RPM-4U120
Grafik Eye QS
Main Unit
Family/
LQRJ-WPM-6P
GP (Harrier)
Card
Grafik Eye 3000
Family/
HWI-WPM-6D120
RRD-6CL (R3)*
HQRD-6CL
(H2)*/
HQRA-6CL (H2)*
FP
1 - 30
12% (17)
100% (73)
35%
FP
1 - 30
8% (12)
100% (72)
28%
FP
1 - 30
10% (13)
99% (75)
32%
FP
1 - 30
8% (12)
100% (72)
28%
FP
FP
1 - 10
1 - 10
17% (29)
17% (29)
100% (99)
100% (99)
41%
41%
FP
1-6
5% (15)
100% (99)
22%
FP
1-6
5% (15)
100% (99)
22%
RP
1-6
9% (12)
99% (75)
30%
RP
1 - 44
8% (15)
100% (73)
28%
High end trim required.
RP
1 - 44
8%
100%
28%
High end trim required.
Grafik QS/
Wallbox Power Module
Panel Module
Grafik Eye 3000/
HomeWorks
RadioRA 2
HomeWorks QS
RadioRA 2
HomeWorks QS
HomeWorksQS/
myRoom
RRD-H6BRL
(with neutral)
HQRD-H6BRL
(with neutral)
LQSE-4A1-D/
MQSE-4A1-D/
MQSE-3A1/
MQSE-2A1-D,
120V
High end trim required. Rating
is per channel; total per module
is 70.
Rating is per channel; total per
module is 30.
Rating is per output; total
quantity per Main Unit is 75.
Rating is per output. Use load
type 2-1.
Rating is per output; total
quantity per Main Unit is
45/56/75/75 for 2/3/4/6-Zone
units, respectively.
Installation with a neutral wire
is required.
Installation with a neutral wire
is required.
Rating is per output; total
quantity per Main Unit is 24.
Interfaces (5)
PHPM-PA
with Grafik Eye
QS Main Unit
PHPM-WBX
with 3-wire
fluorescent
control
Notes:
* Identical model numbers with different compatibility codes may have different performance; (_) means there is no compatibility code assigned;
contact technical support for additional information.
(1) Control types of FP and RP represent Forward Phase and Reverse Phase, respectively. See product literature for details.
(2) Maximum Fixtures per Dimmer value represents the maximum safe loading of the control.
(3) Values are based on light output using the specified dimming control, and may not be an indication of the fixture’s full rated capability.
Values are set to optimize performance, such as reducing dead travel, ensuring that fixtures turn on at low end, reducing turn-on time at
low end, and trimming out instability. Software trim values are indicated in parentheses when applicable.
(4) Perceived light level percentage is the square root of the measured light level percentage, per IESNA Lighting Handbook.
(5) Interfaces have been tested with the listed control; any compatible dimmer may be used instead, but high end/low end light levels may vary
slightly.
Test Comments:
Performance verified with up to 10 fixtures per control.
For any questions on this report, please contact the Lutron LED Center of Excellence at 877-DIM-LED8 or leds@lutron.com.
This information was posted with the consent and cooperation of the device manufacturer. Please be aware that device manufacturers may modify their product at any time, without
notice to Lutron, and therefore Lutron cannot ensure future compatibility. For more detailed and up to date fixture specifications, performance and/or any related recall
information, visit the manufacturer’s website. The latest Lutron test results can always be found at www.lutron.com/LEDtool.
Page 2 of 2
Download