Product Information Combined Coupling/Decoupling

advertisement
Product Information
Combined Coupling/Decoupling Networks
for Burst and Surge CNI501/CNI 503
The coupling/decoupling network type CNI 501/503 is
used for two different applications:
1.
Coupling of Surge and EFT/burst pulses as per
IEC 61000-4-4 Ed.2 and IEC 61000-4-5 Ed.2 onto
single phase or three-phase power mains supply
lines.
2.
Decoupling of the transient pulses from the
public power mains supply to avoid disturbance of
other equipment connected to the mains.
The following instruments are available as standard:
Model
Description
AC supply 50/ 60 Hz
DC supply
CNI 501
CNI 501 S1
CNI 501 S4
4.4kV Coupler/Decoupler
4.4kV Coupler/Decoupler
10kV Coupler/Decoupler
Single phase 250V/ 32A
Single phase 250V/100A
Single phase 250V/ 16A
48V / 32A
48V / 100A
250V / 10A
CNI 503 A
CNI 503 A2
CNI 503 A3
CNI 503 A4
4.4kV Coupler/Decoupler
4.4kV Coupler/Decoupler
4.4kV Coupler/Decoupler
4.4kV Coupler/Decoupler
3 - Phase 3x440V / 16A
3 - Phase 3x440V / 32A
3 - Phase 3x440V / 63A
3 - Phase 3x440V / 100A
250V /
250V /
250V /
250V /
16A
32A
63A
100A
CNI 503 B5
CNI 503 B7
CNI 503 B8
CNI 503 B9
6.6kV Coupler/Decoupler
6.6kV Coupler/Decoupler
6.6kV Coupler/Decoupler
6.6kV Coupler/Decoupler
3 - Phase 3x440V / 16A
3 - Phase 3x440V / 32A
3 - Phase 3x440V / 63A
3 - Phase 3x440V / 100A
250V /
250V /
250V /
250V /
16A
32A
63A
100A
CNI 503 A10
CNI 503 A12
CNI 503 A13
CNI 503 A14
8kV Coupler/Decoupler
8kV Coupler/Decoupler
8kV Coupler/Decoupler
8kV Coupler/Decoupler
3 - Phase 3x440V / 16A
3 - Phase 3x440V / 32A
3 - Phase 3x440V / 63A
3 - Phase 3x440V / 100A
250V /
250V /
250V /
250V /
16A
32A
63A
100A
CNI 503 A16
CNI 503 A18
CNI 503 A19
CNI 503 A20
10kV Coupler/Decoupler
10kV Coupler/Decoupler
10kV Coupler/Decoupler
10kV Coupler/Decoupler
3 - Phase 3x440V / 16A
3 - Phase 3x440V / 32A
3 - Phase 3x440V / 63A
3 - Phase 3x440V / 100A
250V /
250V /
250V /
250V /
16A
32A
63A
100A
Note:
-
The CNI 503 A3/A4, CNI 503 B8/B9,CNI 503 A13/A14 and CNI 503 A19/A20 are designed for
direct rack mounting only!
The units can also be used for ac power line surge as per ANSI IEEE C62.41. This must be
indicated on the order sheet.
EM TEST AG
CH - 4153 Reinach BL
URL: www.emtest.com
Tel:
+41 61 717 91 91
Fax:
+41 61 717 91 99
e-mail: sales@emtest.ch
Data sheet: cni503.doc
Version:
1.08 / 13.04.07
Replace:
1.07 / 01.11.06
St
1/2
Product Information
Combined Coupling/Decoupling Networks
for Burst and Surge CNI501/CNI 503
The following coupling modes are available:
For IEC 61000-4-5
Surge Test
Line to Line with a 2Ω source impedance
Line(s) to PE with a 12Ω source impedance
L to N or + to All combinations
For IEC 61000-4-4
EFT/burst Test
Line(s) to Reference Ground
All combinations
The CNI 501/503 can be used together with the following generators:
For Surge
VCS 500M
TSS 500M2F
UCS 500M4
UCS 500M6
For EFT/burst
EFT 500/500M4
EFT 500M8
EFT 800
UCS 500M4
UCS 500M6
1.2/50µs - 8/20µs
0.5µs/100kHz Ring Wave
<2/>10µs
1.2/50µs - 8/20µs
1.2/50µs - 8/20µs
up to 10,000V as per IEC 61000-4-5
up to 6,000V as per ANSI/IEEE
up to 2,500V as per FCC part 68
up to 4,000V
up to 6,600V
5/50ns
5/50ns
5/50ns
5/50ns
5/50ns
up to 4,400V
up to 7,000V
up to 8,000V
up to 4,400V
up to 5,500V
For more detailed information see the brochures of the individual generators.
EM TEST AG
CH - 4153 Reinach BL
URL: www.emtest.com
Tel:
+41 61 717 91 91
Fax:
+41 61 717 91 99
e-mail: sales@emtest.ch
Data sheet: cni503.doc
Version:
1.08 / 13.04.07
Replace:
1.07 / 01.11.06
St
2/2
Download