Air-insulated medium-voltage switchgear – cleverly switched, local added value Peace of mind, saves lives, increases productivity, saves money Answers for energy. Experience and quality for maximum system safety The industrialized world of today is characterized by a rising energy demand and growing environmental consciousness concurrently with an increasing price pressure. At the same time, users are of course placing maximum demands regarding reliability, personal protection and productivity in connection with switchgear operation. There is one thing you just have to rely on: smooth and safe operation of your system. Around the clock. Here, switchgear assemblies as points of intersection play a decisive role – and air-insulated switchgear concepts from our worldwide production locations offer the best solution with no doubt. As a pioneer for air-insulated switchgear we bring along 25 years of know-how in the development of switchgear and switching devices. Along with this, our manufacturing plants in all regions of the world ensure local added value and thus, permanent proximity to the customer, so that you can take full advantage of airinsulated technology: As insulating medium, air is available day and night, and withdrawable switchgear systems guarantee accessibility to all switchgear components at any time. With air-insulated switchgear from Siemens you are always on the safe side – our switchgear is type-tested for indoor installation according to IEC 62271-200 or ANSI/IEEE C37.20.2. In this way you profit from our leading position as regards fulfillment of this new standard IEC 62271-200. Regardless of the fact that airinsulated switchgear from Siemens has always been a synonym for maximum personal and opera-tional safety as well as local added value. Keep everything going in your power supply system: Air-insulated switchgear from Siemens – for sustainability, safety and efficiency Peace of mind With its sophisticated technology, a globally interconnected R&D network, a worldwide production and quality network and the fulfillment of all type and routine tests according to the requirements of the international standards without restrictions, air-insulated switchgear offers maximum peace of mind. Saves lives All air-insulated switchgear designs from Siemens are approved with internal arc classification IAC A FLR, loss of service continuity category LSC 2B, LSC 2A or LSC 1 depending on the switchgear type, as well as partition class PM. Thus they can be universally installed, fulfilling maximum requirements as regards personal protection. Increases productivity Functions such as evidence of the making and breaking capacity for the built-in circuit-breakers and earthing switches – and even confinement of the arc to the respective compartment depending on the switchgear type – as well as designs equipped to meet maximum requirements with respect to the degree of protection provide uninterrupted operation and an appreciable increase of productivity. Saves money The compact design and the use of vacuum circuit-breakers pay off twice for the switchgear operator. On the one hand, building costs can be reduced, and on the other hand, the maintenance-free design of the circuit-breakers enables continuous operation without expensive downtimes. Siemens – your partner on site We take care that you can “switch cleverly“. Combining innovation, experience and local added value. With comprehensive know-how, worldwide service – and profound understanding of your requirements in the most different regions due to local production capacity. Go and see for yourself! Local added value – systematically: Worldwide production – complete processes – a quality standard R&D headquarters in Germany concentrate international know-how All global development activities are concentrated and controlled centrally: International development teams introduce the respective country-specific requirements in our R&D activities. A good basis for maximum development synergies, contributing to lean development cycles by means of optimal exchange of experience. High demands – in practical implementation: The 3D-CAD procedure During the development and production phase, the utilization of 3D-CAD software ensures perfect quality and reliability. The individual technical data of your switchgear is transferred directly from the purchase order to the production department via the design department. Using innovative technologies we can offer a maximum of quality and flexibility in production – with short delivery times. Local added value – country-specific flexibility Hundreds of Siemens employees manufacture our air-insulated switchgear type series in different regions worldwide. In this way we do not only ensure the local know-how for the requirements varying from country to country, but also integrate experience from other locations. Production processes are documented in a comprehensible way – to reach the quality level you, as our customer, can expect in a fast, safe and reproducible way. Strict eyes – to assure the quality Our very modern, accredited testing laboratories ensure the high quality of our air-insulated switchgear. Besides type and routine tests for the individual switchgear type series, continuous process-accompanying quality assurance according to ISO 9001 and 14001 is performed. Being associated with PEHLA and DAR, our testing laboratories have the status of independent test institutes. Factory Corroios – Portugal Switchgear Factory Frankfurt – Germany Switchgear Factory Berlin – Germany P roducts: •A ir-insulated medium-voltage switchgear (NXAIR, SIMOPRIME) R &D headquarters for air-insulated switchgear Products: • SF6-insulated medium-voltage switchgear R &D headquarters for vacuum circuit-breakers Products: • Vacuum circuit-breakers (3AH, SION) • Vacuum contactors (3TL) Factory Bogotá – Colombia Factory Jundiai – Brazil Factory Kyalami – Republic of South Africa P roducts: •A ir-insulated medium-voltage switchgear (8BK, SIMOPRIME) Products: • Air-insulated medium-voltage switchgear (8BK, SIMOPRIME) • Assembly of vacuum circuitbreakers P roducts: •A ir-insulated medium-voltage switchgear (SIMOPRIME) Factory Querétaro – Mexico Products: • Air-insulated medium-voltage switchgear (8BK, NXAIR, SIMOPRIME, 8BT2, GM) • Vacuum circuit-breakers – indoor and outdoor installation Interrupter Factory Berlin – Germany Factory Kartal – Turkey R &D headquarters for vacuum interrupters Products: • Vacuum interrupters for circuitbreakers and contactors P roducts: •A ir-insulated medium-voltage switchgear (8BK, 8BT, SIMOPRIME) Factory Shanghai – China Products: • Air-insulated medium-voltage switchgear (8BK, NXAIR S) • Vacuum circuit-breakers Factory Jakarta – Indonesia P roducts: •A ir-insulated medium-voltage switchgear (8BK, SIMOPRIME) Factory Jeddah – Saudi Arabia Factory Karachi – Pakistan Factory Kalwa – India P roducts: •A ir-insulated medium-voltage switchgear (8BK) P roducts: •A ir-insulated medium-voltage switchgear (8BK, SIMOPRIME) Products: • Air-insulated medium-voltage switchgear (8BK80/88 PLUS) • Vacuum circuit-breakers – indoor and outdoor installation The suitable switchgear – for every region and every requirement Your region, your requirements – and the suitable solution from Siemens. For every distribution level, every rating, every application and every switchgear type. To help you find information about the medium-voltage switchgear you need, we have listed our type series in the selection matrix given below in accordance with the most important criteria. For a fast overview, just leave this page unfolded. Region Standard Loss of service continuity category, partition class Internal arc classification Busbar system Switchgear type U kV Isc kA Ibusbar A Ifeeder A Page IEC 62271-200 LSC 2B / PM IAC A FLR ISC, t Single / Double NXAIR 12 31.5 2500 2500 8 NXAIR M 24 25 2500 2500 8 NXAIR P 15 50 4000 4000 8 SIMOPRIME 17.5 40 3600 3600 9 8BT1 12 25 2000 2000 10 24 25 2000 2000 Europe Portugal Turkey IEC 62271-200 LSC 2A / PM IAC A FLR ISC, t Single LSC 2B / PM 8BT2 36 31.5 2500 2500 10 LSC 1 8BT3 36 16 1250 1250 10 LSC 2B / PM SIMOPRIME 17.5 40 3600 3600 9 SIMOPRIME 17.5 40 3600 3600 9 8BT2 36 31.5 2500 2500 10 America Mexico Brazil Colombia IEC 62271-200 LSC 2B / PM IAC A FLR ISC, t Single IEC 60298 Metal-clad IAC A FLR (IEC 60298) Single 8BK20/ 8BK30 15 50 4000 4000 ANSI C37.20 Metal-clad acc. to standard Single GM SG 15 63 4000 4000 12 ANSI C37.20 Metal-clad acc. to standard Single GM 38 38 31.5 2500 2500 12 IEC 62271-200 LSC 2B / PM IAC A FLR ISC, t Single SIMOPRIME 17.5 40 3600 3600 9 IEC 60298 Metal-clad IAC A FLR (IEC 60298) Single 8BK20/ 8BK30 15 50 4000 4000 IEC 62271-200 LSC 2B / PM IAC A FLR ISC, t Single SIMOPRIME 17.5 40 3600 3600 IEC 60298 Metal-clad IAC A FLR (IEC 60298) Single 8BK20/ 8BK30 15 50 4000 4000 IEC 62271-200, GB, DL LSC 2B / PM IAC A FLR ISC, t Single NXAIR S 12 40 3150 3150 IEC 60298 Metal-clad IAC A FLR (IEC 60298) Single 8BK20/ 8BK30 12 50 4000 4000 IEC 60298 Metal-clad – Single 8BK40 12 63 4500 4500 IEC 62271-200 LSC 2B / PM IAC A FLR ISC, t Single 8BK80 12 44 3150 3150 36 31.5 3150 3150 9 Asia China India Indonesia Pakistan Saudi Arabia 8 11 8BK88 plus 12 25 1600 1600 11 IEC 62271-200 LSC 2B / PM IAC A FLR ISC, t Single SIMOPRIME A4 24 25 2500 2500 9 IEC 60298 Metal-clad IAC A FLR (IEC 60298) Single 8BK20/ 8BK30 12 50 4000 4000 IEC 62271-200 LSC 2B / PM IAC A FLR ISC, t Single SIMOPRIME A4 24 25 2500 2500 IEC 60298 Metal-clad IAC A FLR (IEC 60298) Single 8BK20/ 8BK30 12 50 4000 4000 IEC 60298 Metal-clad IAC A FLR (IEC 60298) Single 8BK20/ 8BK30 15 50 4000 4000 IEC 62271-200 LSC 2B / PM IAC A FLR ISC, t Single SIMOPRIME 17.5 40 3600 3600 9 Africa South Africa 9 NXAIR family High-end technology at its best T ype-tested, IEC 62271-200, metal-clad, loss of service continuity category: LSC 2B, partition class: PM Internal arc classification: IAC A FLR ≤ 50 kA 1s As insulating medium, air is always available Evidence of the making and breaking capacity for the circuit-breakers and the make-proof earthing switches in the panel 42 kV, 1 min power-frequency withstand voltage for NXAIR and NXAIR S Single busbar, double busbar (back-to-back, face-to-face) Withdrawable vacuum circuit-breaker Withdrawable vacuum contactor Maximum availability due to modular design Selective shutdown by means of transformer principle and pressure-resistant partition Maximum security of operation by self-explaining operating logic Maintenance intervals > 10 years NXAIR NXAIR M Switchgear Technical data type U Isc Ibusbar kV kA A Ifeeder A Width mm Height Depth mm mm NXAIR ≤ 12 ≤ 31.5 ≤ 2500 ≤ 2500 400 650 800 2300 1350 1400 NXAIR M 24 ≤ 25 ≤ 2500 ≤ 2500 800 1000 2550 1554 NXAIR P ≤ 15 40 50 ≤ 4000 ≤ 4000 400 800 1000 2550 1635 1650 NXAIR S ≤ 12 ≤ 40 ≤ 3150 ≤ 3150 800 2300 1350 NXAIR P NXAIR S SIMOPRIME family The first choice for standard applications T ype-tested, IEC 62271-200, metal-clad, loss of service continuity category: LSC 2B, partition class: PM Internal arc classification: IAC A FLR ≤ 40 kA 1s As insulating medium, air is always available Evidence of the making and breaking capacity for the circuit-breakers and the make-proof earthing switches in the panel Withdrawable vacuum circuit-breaker Withdrawable vacuum contactor All switching operations with door closed SIMOPRIME Switchgear Technical data type U Isc Ibusbar kV kA A Ifeeder A Width mm Height Depth mm mm SIMOPRIME ≤ 17.5 ≤ 40 ≤ 3600 ≤ 3600 400 600 800 2200 1860 SIMOPRIME A4 24 ≤ 25 ≤ 2500 ≤ 2500 800 1000 2250 1950 SIMOPRIME A4 8BT family Compact design and simple construction T ype-tested, IEC 62271-200, metal-clad, loss of service continuity category: LSC 2A for 8BT1, LSC 2B for 8BT2, LSC 1 for 8BT3, partition class: PM for 8BT1, 8BT2 Internal arc classification: IAC A FLR ≤ 31.5 kA 1s As insulating medium, air is always available Evidence of the making and breaking capacity for the circuit-breakers and the make-proof earthing switches in the panel Withdrawable vacuum circuit-breaker All switching operations with door closed 8BT1 10 8BT2 Switchgear Technical data type U Isc Ibusbar kV kA A Ifeeder A Width mm Height Depth mm mm 8BT1 ≤ 12 24 ≤ 25 ≤ 25 ≤ 2000 ≤ 2000 ≤ 2000 ≤ 2000 600/800 2050 800/1000 2050 1410 1410 8BT2 36 ≤ 31.5 ≤ 2500 ≤ 2500 1550 2400 2450 2700 8BT3 ≤ 36 ≤ 16 ≤ 1250 ≤ 1250 1000 2400 1500 8BT3 8BK80 family Designed for local applications T ype-tested, IEC 62271-200, metal-clad, loss of service continuity category: LSC 2B, partition class: PM Internal arc classification: IAC A FLR ≤ 44 kA 1s As insulating medium, air is always available Evidence of the making and breaking capacity for the circuit-breakers and the make-proof earthing switches in the panel Withdrawable vacuum circuit-breaker Withdrawable vacuum contactor All switching operations with door closed 8BK80 Switchgear Technical data type U Isc Ibusbar kV kA A Ifeeder A Width mm 8BK80 ≤ 15 ≤ 44 ≤ 3150 ≤ 3150 600/800 2450 1750 8BK80 36 ≤ 31.5 ≤ 2000 ≤ 2000 1100 2250 2700 ≤ 25 ≤ 1600 ≤ 1600 600 2100 1350 8BK88 PLUS ≤ 12 Height Depth mm mm 8BK88 PLUS 11 GM family Their strength is flexibility T ype-tested, ANSI/IEEE C 37.20.2, metal-clad, tested for resistance to internal faults As insulating medium, air is always available Evidence of the making and breaking capacity for the circuit-breakers and the make-proof earthing switches in the panel Withdrawable vacuum circuit-breaker, also in “two-level design” All switching operations with door closed GM SG 12 Switchgear Technical data type U Isc Ibusbar kV kA A Ifeeder A Width mm Height Depth mm mm GM SG ≤ 15 ≤ 63 ≤ 4000 ≤ 4000 914 (36‘‘) 2343 2502 (92.25‘‘) (98.5‘‘) GM 38 38 ≤ 31.5 ≤ 2500 ≤ 2500 1219 (48‘‘) 3302 (130‘‘) GM 38 3302 (130‘‘) Ordering For further information about the switchgear, please refer to the following catalogs: Please contact your local sales partner, who will send the selected information material to your address. Company Dept. Name C ircuit-breaker switchgear type NXAIR, NXAIR M, NXAIR P, up to 24 kV, air-insulated HA 25.71.2007 German English C ircuit-breaker switchgear type NXAIR S, up to 12 kV, air-insulated English Chinese C ircuit-breaker switchgear type SIMOPRIME, up to 17.5 kV, air-insulated HA 26.11.2007 German English Spanish French Street Postal code/city Phone Fax C ircuit-breaker switchgear type SIMOPRIME A4, up to 24 kV, air-insulated English ircuit-breaker switchgear type 8BT1, up to 24 kV, C air-insulated HA 26.31.2007 German English C ircuit-breaker switchgear type 8BT2, up to 36 kV, 31.5 kA, air-insulated HA 26.41.2007 English Turkish 8BT3-SYSTEM, 36 kV, 16 kA, air-insulated, truck-type switchgear English 8BK80, metal-clad switchgear up to 12 kV English 8BK88 PLUS, compact metal-clad switchgear up to 12 kV English Medium-voltage switchgear GM-SG, 5 kV – 15 kV English 13 Published by and Copyright © 2008 Siemens AG Energy Sector Freyeslebenstr. 1 91058 Erlangen, Germany Siemens AG Energy Sector Power Distribution Division Medium Voltage Mozartstr. 31c 91052 Erlangen, Germany Please contact us at: Tel.: +49 180 / 524 70 00 Fax: +49 180 / 524 24 71 (Charges depending on provider) E-Mail: support.energy@siemens.com www.siemens.com/energy-support Power Distribution Division Order no. E50001-U229-A228-X-7600 Printed in Germany Dispo 30400 GB 080134 102449 WS 06085.0 Subject to change witout prior notice. The information in this document contains general descriptions of the technical options available, which may not apply in all cases. The requiredtechnical options should therefore be specified in the contract. www.siemens.com/energy