Technical Data IEC Starter Approximate Dimensions Bulletin Numbers 103H/107H/140M, 103-C/107/C, 105, 109, 106, 112, 113, 190E/191E, 190S/191S, 103S/107S, 103T/107T Topic Page Enclosed Starters and Motor Protectors 35 103H/107H/140M Enclosed Combination Starters and Motor Protectors 35 Plastic Lift-off Enclosures 37 Metal Lift-Off and Hinged Enclosures Open Starters 42 35 Starters with Eutectic Alloy Overload Relay 35 Bulletin 103S/107S Combination Starters 36 Additional Resources These documents contain additional information concerning related products from Rockwell Automation. Resource Description Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1 Provides general guidelines for installing a Rockwell Automation industrial system. Product Certifications website, http://www.ab.com Provides declarations of conformity, certificates, and other certification details. You can view or download publications at http://www.rockwellautomation.com/literature/. To order paper copies of technical documentation, contact your local Allen-Bradley distributor or Rockwell Automation sales representative. IEC Starter Approximate Dimensions Notes: 2 Rockwell Automation Publication 100-TD015B-EN-P - May 2015 Enclosed Starters and Motor Protectors Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes 103H/107H/140M Enclosed Combination Starters and Motor Protectors Figure 8 - Enclosure Style A Figure 9 - Enclosure Style B Rockwell Automation Publication 100-TD015B-EN-P - May 2015 35 Figure 10 - Enclosure Style C 36 Rockwell Automation Publication 100-TD015B-EN-P - May 2015 Plastic Lift-off Enclosures Bulletin 109 Plastic Lift-Off Enclosure Figure 11 - Cat. Nos. 198E-A0S1, -C0S1, -C0S4 207.9 (8.19) 188 (7.41) 25.2 (0.99) 5.5 (0.22) 97.9 (3.86) 111 (4.37) Rockwell Automation Publication 100-TD015B-EN-P - May 2015 37 Figure 12 - Cat. No. 198E-C0S4R 125 [4.93] 125 [4.93] 235 [9.26] 13 [0.51] 250 [9.85] 16 [0.63] 3.5 [0.14] 100 [3.94] 111.5 [4.39] Ø23 [Ø0.91] 30 [1.18] 50 [1.97] 110 [4.33] 88.6 [3.49] 125 [4.93] 28.1 [1.11] 50 [1.97] 50 [1.97] 24 [0.95] Rotary operator alternatively (for maintained control) 10 Pozidriv No. 2 Pozidriv No. 2 (1.2 x 6.5) 2.0 Nm 18 lb-in 38 2 x 1...6 mm² 2 x No. 14...10 AWG Rockwell Automation Publication 100-TD015B-EN-P - May 2015 2.3 Nm 20 lb-in Figure 13 - Cat. No. 198E-C2S4 125 [4.93] 125 [4.93] 16 [0.63] 3.5 [0.14] 235 [9.26] 113.6 [4.48] 13 [0.51] 30 [1.18] 50 [1.97] 110 [4.33] 78 [3.07] 125 [4.93] 50 [1.97] 24 [0.95] Rotary operator alternatively (for maintained control) 28.1 [1.11] 50 [1.97] 169 [6.66] 250 [9.85] Ø23 [Ø0.91] 10 Pozidriv No. 2 Pozidriv No. 2 (1.2 x 6.5) 2.0 Nm 18 lb-in 2 x 1...6 mm² 2 x No. 14...10 AWG Rockwell Automation Publication 100-TD015B-EN-P - May 2015 2.3 Nm 20 lb-in 39 103C/107C Plastic Lift-Off Enclosure Figure 14 - Cat. No. 198E-C0C4R 3.5 [0.14] 235 [9.26] Ø15 [Ø0.59] 32.5 [1.28] 13 [0.51] Ø3.5 [Ø0.14] 125 [4.93] Ø23 [Ø0.91] 14.1 [0.56] 14.1 [0.56] 150 [5.91] 14.1 [0.56] 159.3 [6.28] 250 [9.85] 14.1 [0.56] 125 [4.93] 38.7 [1.52] 50 [1.97] 110 [4.33] 95 [3.74] 125 [4.93] 28.1 [1.11] 50 [1.97] 50 [1.97] 24 [0.95] Rotary operator alternatively (for maintained control) 10 Pozidriv No. 2 Pozidriv No. 2 (1.2 x 6.5) 2.0 Nm 18 lb-in 40 2 x 1...6 mm² 2 x No. 14...10 AWG Rockwell Automation Publication 100-TD015B-EN-P - May 2015 2.3 Nm 20 lb-in 105C Plastic Lift-Off Enclosure Figure 15 - Cat. No. 198E-C0S4R 125 [4.93] 125 [4.93] 235 [9.26] 13 [0.51] 3.5 [0.14] 111.5 [4.39] Ø23 [Ø0.91] 100 [3.94] 30 [1.18] 50 [1.97] 110 [4.33] 88.6 [3.49] 50 [1.97] 24 [0.95] Rotary operator alternatively (for maintained control) 125 [4.93] 28.1 [1.11] 50 [1.97] 250 [9.85] 16 [0.63] 10 Pozidriv No. 2 Pozidriv No. 2 (1.2 x 6.5) 2.0 Nm 18 lb-in 2 x 1...6 mm² 2 x No. 14...10 AWG Rockwell Automation Publication 100-TD015B-EN-P - May 2015 2.3 Nm 20 lb-in 41 Metal Lift-Off and Hinged Enclosures Bulletin 109 Metal Lift-Off Enclosures, Type 1 (IP42) Figure 16 - 109 Metal Lift-off Enclosures 23.4 (0.921) B D A F Contactor Size C09…C23 C30…C55 C60…C72 C85 C09…C23 C30…C55 C60…C72 C85 42 C E 7.1 (0.28) dia. For 1/4 in. or M6 Screw 3 mtg. holes A Height B Width C Depth D E IP42 (Type 1) General Purpose Metal Lift-Off Enclosure for Bulletin 109 (Without Transformer) 328 (12.91) 187 (7.35) 140 (5.52) 277 (10.75) 133 (5.24) 305 (12) 178 (7) 203 (8) 270 (10-5/8) 140 (5-33/64) 585 (23-1/32) 257 (10-7/64) 203 (8) 540 (21-17/64) 210 (8-17/64) IP42 (Type 1) General Purpose Metal Lift-Off Enclosure for Bulletin 109 (With Transformer) F 27(1.06) 24 (15/16) 23.5 (59/64) 328 (12.91) 187 (7.35) 140 (5.52) 277 (10.75) 133 (5.24) 27(1.06) 315 (12-27/64) 585 (23-1/32) 325 (12-51/64) 257 (10-7/64) 203 (8) 203 (8) 270 (10-5/8) 540 (21-17/64) 280 (11-1/64) 210 (8-17/64) 22.5 (57/64) 23.5 (59/64) Rockwell Automation Publication 100-TD015B-EN-P - May 2015 105 Metal Lift-Off Enclosures Type 1 (IP42) Figure 17 - 105 Metal Lift-Off Enclosure 23.4 (0.921) B D A F Contactor Size A Height C09…C37 C43 C60…C72 C85 328 (12.91) 290 (11-27/64) 315 (12-27/64) 610 (24) C09…C23 C30…C43 290 (11-27/64) 315 (12-27/64) C E 7.1 (0.28) dia. For 1/4 in. or M6 Screw 3 mtg. holes B Width C Depth D E F IP42 (Type 1) General Purpose Metal Lift-off Enclosure for Bulletin 105 (Without Transformer) 187 (7.36) 140 (5.52) 273 (10.75) 133 (5.24) 27 (1.06) 270 (10-5/8) 152 (5-31/32) 245 (9-41/32) 225 (8-55/64) 22.5 (57/64) 325 (12-51/64) 203 (8) 270 (10-5/8) 280 (11-1/64) 22.5 (57/64) 406 (16) 230 (9-1/16) 572 (22-1/2) 368 (14-1/2) 19 (3/4) IP42 (Type 1) General Purpose Metal Lift-Off Enclosure for Bulletin 105 (With Transformer) 270 (10-5/8) 152 (5-31/32) 245 (9-41/64) 225 (8-55/64) 22.5 (57/64) 325 (12-51/64) 203 (8) 270 (10-5/8) 280 (11-1/64) 22.5 (57/64) Rockwell Automation Publication 100-TD015B-EN-P - May 2015 G (diameter) — — — 11 (7-16) — — 43 106, 112, and 113 Metal Hinged Enclosures Type 1 (IP42), Type 3/4/12 (IP66) Figure 18 - 106, 112, and 113 Metal Hinged Enclosures Contactor Size C09…C43 C60…C72 C09…C23 C30…C43 C60…C72 C30…C72 A Height B Width C Depth D E F IP42 (Type 1) and IP66 (Type 3/4/12) General Purpose Metal Hinged Enclosure for Bulletin 106 (With and Without Transformer) 350 (13-25/32) 400 (15-3/4) 200 (7-7/8) 315 (12-13/32) 178 (7) 62 (2-7/16) 610 (24) 406 (16) 224 (8-13/16) 572 (22-1/2) 368 (14-1/2) 19 (3/4) IP42 (Type 1) and IP66 (Type 3/4/12) General Purpose Metal Hinged Enclosure for Bulletin 112 (With and Without Transformer) 350 (13-25/32) 200 (7-7/8) 200 (7-7/8) 315 (12-13/32) 76 (3) 62 (2-7/16) 350 (13-25/32) 400 (15-3/4) 200 (7-7/8) 315 (12-13/32) 178 (7) 111 (4-3/8) 610 (24) 406 (16) 224 (8-13/16) 572 (22-1/2) 368 (14-1/2) 19 (3/4) IP42 (Type 1) and IP66 (Type 3/4/12) General Purpose Metal Hinged Enclosure for Bulletin 113 (With and Without Transformer) 610 (24) 406 (16) 224 (8-13/16) 572 (22-1/2) 368 (14-1/2) 19 (3/4) G (diameter) 6.4 (1/4) 12.7 (1/2) 6.4 (1/4) 6.4 (1/4) 12.7 (1/2) 12.7 (1/2) 109 Metal Hinged Enclosures Type 3/4/12 (IP66) Figure 19 - 109 Metal Hinged Enclosures Contactor Size A Height C09…C43 C60…C72 C85 300 (11-13/16) 350 (13/25/32) 762 (30) C09…C23 C30…C43 C60…C72 C85 300 (11-13/16) 300 (11-13/16) 350 (13-25/32) 610 (24) 44 B Width C Depth D E IP66 (Type 3/4/12) Metal Hinged Enclosure for Bulletin 109 (Without Transformer) 200 (7-7/8) 160 (6-5/16) 265 (10-7/16) 76 (3) 200 (7-7/8) 210 (8-9/32) 315 (12-13/32) 76 (3) 305 (12) 276 (10-7/8) 724 (28-1/2) 267 (10-1/2) IP66 (Type 3/4/12) Metal Hinged Enclosure for Bulletin 109 (With Transformer) 200 (7-7/8) 160 (6-5/16) 265 (10-7/16) 76 (3) 300 (11-13/16) 160 (6-5/16) 236 (9-5/16) 178 (7) 400 (15-3/4) 210 (8-9/32) 315 (12-13/32) 178 (7) 406 (16) 230 (9-1/16) 572 (22-1/2) 368 (14-1/2) Rockwell Automation Publication 100-TD015B-EN-P - May 2015 F G (diameter) 62 (2-7/16) 62 (2-7/16) 19 (3/4) 5.5 (7/32) 5.5 (7/32) 11 (7/16) 62 (2-7/16) 61 (2-13/32) 111 (4-3/8) 19 (3/4) 5.5 (7/32) 5.5 (7/32) 5.5 (7/32) 11 (7/16) 105 Metal Hinged Enclosures Type 3/4/12 (IP66) Figure 20 - 105 Metal Hinged Enclosures Contactor Size A Height C09…C23 C30…C43 C60…C72 C85 250 (9-13/16) 300 (11-13/16) 350 (13/25/32) 610 (24) C09…C23 C30…C43 C60…C72 C85 300 (11-13/16) 350 (13-25/32) 610 (24) 762 (30) B Width C Depth D E IP66 (Type 3/4/12) Metal Hinged Enclosure for Bulletin 105 (Without Transformer) 250 (9-13/16) 160 (6-5/16) 186 (7-5/16) 76 (3) 300 (11-13/16) 160 (6-5/16) 178 (7) 400 (15-3/4) 210 (8-9/32) 315 (12-13/32) 178 (7) 406 (16) 230 (9-1/16) 572 (22-1/2) 368 (14-1/2) IP66 (Type 3/4/12) Metal Hinged Enclosure for Bulletin 105 (With Transformer) 200 (7-7/8) 160 (6-5/16) 236 (9-5/16) 178 (7) 400 (15-3/4) 210 (8-9/32) 315 (12-13/32) 178 (7) 406 (16) 230 (9-1/16) 572 (22-1/2) 368 (14-1/2) 610 (24) 281 (11-1/16) 724 (28-1/2) 572 (22-1/2) Rockwell Automation Publication 100-TD015B-EN-P - May 2015 F G (diameter) 87 (3-13/32) 61 (2-13/32) 111 (4-3/8) 19 (3/4) 5.5 (7/32) 5.5 (7/32) 5.5 (7/32) 11 (7/16) 61 (2-13/32) 111 (4-3/8) 19 (3/4) 19 (3/4) 5.5 (7/32) 5.5 (7/32) 11 (7/16) 11 (7/16) 45 46 Rockwell Automation Publication 100-TD015B-EN-P - May 2015 Open Starters Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes Starters with Eutectic Alloy Overload Relay Figure 8 - 105 and 109 Open Style Starters G Starter Current Rating [A] 9…23 30 109, 37…43 AC or DC voltage 60 72 9…23 30 105, 37…43 AC or DC voltage 60 72 Starter Type A Height B Width C Depth D E F G (diameter) H 202.4 (7-63/64) 247.6 (9-3/4) 247.6 (9-3/4) 323.9 (12-3/4) 323.9 (12-3/4) 202.4 (7-63/64) 247.6 (9-3/4) 247.6 (9-3/4) 323.9 (12-3/4) 323.9 (12-3/4) 69.8 (2-3/4) 88.9 (3-1/2) 88.9 (3-1/2) 127 (5) 137.6 (5-27/64) 120.6 (4-3/4) 152.4 (6) 152.4 (6) 241.3 (9-1/2) 251.9 (9-15/16) 98.4 (3-57/64) 110.8 (4-23/64) 120.8 (4-3/4) 133.1 (5-15/16) 133.1 (5-15/16) 98.4 (3-57/64) 110.8 (4-23/64) 120.8 (4-3/4) 133.1 (5-15/16) 133.1 (5-15/16) 190.5 (7-1/2) 235.7 (9-9/32) 235.7 (9-9/32) 308.1 (12-9/64) 308.1 (12-9/64) 190.5 (7-1/2) 235.7 (9-9/32) 235.7 (9-9/32) 308.1 (12-9/64) 308.1 (12-9/64) 5.08 (2) 69.8 (2-3/4) 69.8 (2-3/4) 101.6 (4) 101.6 (4) 101.6 (4) 133.3 (5-1/4) 133.3 (5-1/4) 215.9 (8-1/2) 215.9 (8-1/2) 9.5 (25/64) 9.5 (25/64) 9.5 (25/64) 12.7 (1-1/2) 12.7 (1-1/2) 9.5 (25/64) 9.5 (25/64) 9.5 (25/64) 12.7 (1-1/2) 12.7 (1-1/2) 34.9 (1-25/64) 44.4 (1-3/4) — — — 60.4 (2-25/64) 76.2 (3) 76.2 (3) — — — — 76.2 (3) 101.6 (4) 101.6 (4) — — — 215.9 (8-1/2) 215.9 (8-1/2) Rockwell Automation Publication 100-TD015B-EN-P - May 2015 35 Bulletin 103S/107S Combination Starters Standard and ISO Busbar Mount — Bulletin 103S Non-Reversing and 107S Reversing Starters (a) With additional side-mount aux. or trip contact(s) (b) Standard busbar mount with control plug (c) Iso busbar mount (d) Electronic interface 9 (d) 244 (b) / 249 (c) 65 (b) / 70 (c) 105 9 (d) 213 (b) / 218 (c) 60 60 12...30 205.5 (b) / 210.5 (c) 97.5 9 (d) 236.5 (b) / 241.5 (c) 65 (b) / 70 (c) 34 (b) 39 (c) 31 34 (b) 39 (c) 60 60 12...30 36 (a) With additional side-mount aux. or trip contact (b) Standard busbar mount with control plug (c) Iso busbar mount (d) Electronic interface Circuit Breaker: 140M-F Contactor: 100-C30...37 Reference Print: D10GMF 54 Circuit Breaker: 140M-D Contactor: 100-C30...37 Reference Print: D10GMD 63 (a) 54 31 Circuit Breaker: 140M-C / -D Contactor: 100-C09...23 Reference Print: D00GMD 244 (b) / 249 (c) 65 (b) / 70 (c) 105 60 12...30 54 (a) 45 213 (b) / 218 (c) 60 236.5 (b) / 241.5 (c) 97.5 12...30 9 (d) 60 205.5 (b) / 210.5 (c) 60 34 (b) 39 (c) 65 (b) / 70 (c) 34 (b) 39 (c) 31 31 Figure 9 - 103S Busbar Mount 63 (b) Standard busbar mount with control plug Circuit Breaker: 140M-F (c) Iso busbar mount Contactor: 100-C43 (d) Electronic interface Reference Print: D20GMF Rockwell Automation Publication 100-TD015B-EN-P - May 2015 (b) Standard busbar mount with control plug (c) Iso busbar mount (d) Electronic interface 213 (b) / 218 (c) 105 117 (a) (a) With additional side-mount aux. contacts (b) Standard busbar mount with control plug (c) Iso busbar mount (d) Electronic interfaces (a) With additional side-mount aux. contacts (b) Standard busbar mount with control plug (c) Iso busbar mount (d) Electronic interface Circuit Breaker: 140M-F Contactors: 100-C30...37 Reference Print: R10GMF 105 213 (b) / 218 (c) 244 (b) / 249 (c) 65 (b) / 70 (c) 60 117 135 (a) (a) With additional side-mount aux. contacts (b) Standard busbar mount with control plug (c) Iso busbar mount (d) Electronic interface Circuit Breaker: 140M-F Contactors: 100-C43 Reference Print: R20GMF Rockwell Automation Publication 100-TD015B-EN-P - May 2015 9 (d) 99 117 (a) 9 (d) 12...30 60 236.5 (b) / 241.5 (c) 205.5 (b) / 210.5 (c) 12...30 60 97.5 60 34 (b) 39 (c) 65 (b) / 70 (c) 34 (b) 39 (c) 31 31 Circuit Breaker: 140M-D Contactors: 100-C09...23 Reference Print: R00GMD Circuit Breaker: 140M-D Contactors: 100-C30...37 Reference Print: R10GMD 244 (b) / 249 (c) 65 (b) / 70 (c) 34 (b) 39 (c) 60 99 9 (d) 99 117 (a) 9 (d) 12...30 60 236.5 (b) / 241.5 (c) 205.5 (b) / 210.5 (c) 12...30 60 97.5 60 65 (b) / 70 (c) 34 (b) 39 (c) 31 31 Figure 10 - 107S Busbar Mount (a) With additional side-mount aux. contacts (b) Standard busbar mount with control plug (c) Iso busbar mount (d) Electronic interface 37 Panel Mount — 103S Non-Reversing and 107S Reversing Starters Figure 11 - 103S Panel Mount 31 (b) 40 40 (a) 228 125 210 228 125 31 (b) 31 (b) 210 97.5 105 69 64 69 64 31 (b) 35 54 (a) 45 Circuit Breaker: 140M-C/D Contactor: 100-C09...23 Reference Print: D00WMD (a) With additional side-mount aux. or trip contact(s) (b) Control plug on top OR bottom side optional 54 Circuit Breaker: 140M-F Contactor: 100-C30...37 Reference Print: D10WMF (a) With additional side-mount aux. or trip contact (b) Control plug on top OR bottom side optional 40 228 69 125 210 31 (b) 31 (b) 125 228 105 64 69 210 97.5 64 31 (b) 31 (b) 40 63 54 Circuit Breaker: 140M-D Contactor: 100-C30...37 Reference Print: D10WMD 38 (b) Control plug on top OR bottom side optional Circuit Breaker: 140M-F Contactor: 100-C43 Reference Print: D20WMF Rockwell Automation Publication 100-TD015B-EN-P - May 2015 (a) With additional side-mount aux. or trip contact (b) Control plug on top OR bottom side optional Figure 12 - 107S Panel Mount 87 64 228 31 (b) 31 (b) 125 105 125 210 69 64 228 69 97.5 210 31 (b) 31 (b) 87 99 99 117 (a) 117 (a) Circuit Breaker: 140M-C/D Contactors: 100-C09...23 Reference Print: R00WMD (a) With additional side-mount aux. contacts (b) Control plug on top OR bottom side optional Circuit Breaker: 140M-F Contactors: 100-C30...37 Reference Print: R10WMF (a) With additional side-mount aux. contacts (b) Control plug on top OR bottom side optional 103 228 69 31 (b) 125 105 31 (b) 125 210 64 228 69 210 97.5 64 31 (b) 31 (b) 87 117 99 135 (a) 117 (a) Circuit Breaker: 140M-D Contactors: 100-C30...37 Reference Print: R10WMD (a) With additional side-mount aux. contacts (b) Control plug on top OR bottom side optional Circuit Breaker: 140M-F Contactors: 100-C43 Reference Print: R20WMF Rockwell Automation Publication 100-TD015B-EN-P - May 2015 (a) With additional side-mount aux. contacts (b) Control plug on top OR bottom side optional 39 Figure 13 - Cat. No. 140M-C-TE1 Type E adapter on Cat. No. 140M-C2E… Figure 14 - Cat. No. 140M-C-TE1 Type E adapter on Cat. No. 140M-D8E… Figure 15 - Cat. No. 140M-C-TE1 Type E adapter on Cat. No. 140M-F8E… 40 Rockwell Automation Publication 100-TD015B-EN-P - May 2015 Figure 16 - Screw Adapter 140M-C-N45 for 140M-C2/D8 and 140M-F8 . . . Figure 17 - Cat. No. 140M-C with Busbar § Compact Busbar Feeder Terminal IEC Compact Busbar Feeder Terminal UL type E and IEC Mounting on 35 mm DIN Rail § Top Hat Rail Adapter 10 mm Rockwell Automation Publication 100-TD015B-EN-P - May 2015 41 Figure 18 - 140M-C-SHS Screw Adapter > 10 (25/64) 205 (8-5/64) 140M-C 215 (8-31/64) 140M-D / 140U-D 245 (9-41/64) 140M-F Figure 19 - 140M-C-D…66 4.5 (0.18) min. 100 (3.93) 3.5 (0.14) 1.5...5 0.06…0.19) 35...45 (1.4…1.8) b 53.5 (2.10) 53.5 (2.10) 140M-C-DS 140M-C-DSL a ±5 (0.19) 4...8 (0.16…0.31) c1 ±5 (0.19) 4.5 (0.18) c2 2.4 (0.09) Cat. No. 140M-C 140M-D 140M-F 42 With Cat. No. 140-M-C-DS Shaft a b 117…338 105.5 ±5 126…347 114.5 ±5 148.6…369.6 137.1 ±5 c1 49.5 49.5 59.35 c2 40.5 40.5 50.35 a 117…438 126…497 148.6…519 With Cat. No. 140-M-C-DSL Shaft b c1 105.5 ±5 49.5 114.5 ±5 49.5 137.1 ±5 59.35 Rockwell Automation Publication 100-TD015B-EN-P - May 2015 c2 40.5 40.5 50.35 Figure 20 - 140M-C-WBE Figure 21 - Cat. No. 198E… Ø Ø Ø Rockwell Automation Publication 100-TD015B-EN-P - May 2015 43 Figure 22 - 140-CMN Figure 23 - 140-CD… 1.5…5 (0.059…0.197) 5 (0.197) min. 100 (3.94) 3.5 (1.38) 3.5…4.5 (1.38…1.77) ±5 (0.197) 169 (6.65) 53.5 (2.10) 180…402 (7.09…50.83) 53.5 (2.10) ±5 (0.197) 4…8 (0.157…0.314) 44 Rockwell Automation Publication 100-TD015B-EN-P - May 2015 Figure 24 - Mounting position/safety clearance of Cat. No. 140-CMN 70 (2.75) 90 ° 90 ° ° 90 30° 70 (2.75) Rockwell Automation Publication 100-TD015B-EN-P - May 2015 45 46 Rockwell Automation Publication 100-TD015B-EN-P - May 2015 IEC Starter Approximate Dimensions Rockwell Automation Publication 100-TD015B-EN-P - May 2015 1 Important User Information Read this document and the documents listed in the additional resources section about installation, configuration, and operation of this equipment before you install, configure, operate, or maintain this product. Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws, and standards. Activities including installation, adjustments, putting into service, use, assembly, disassembly, and maintenance are required to be carried out by suitably trained personnel in accordance with applicable code of practice. If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment. The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or liability for actual use based on the examples and diagrams. No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software described in this manual. Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation, Inc., is prohibited. Documentation Feedback Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document, complete this form, publication RA-DU002, available at http://www.rockwellautomation.com/literature/. Allen-Bradley, Rockwell Software, Rockwell Automation, and LISTEN. THINK. SOLVE are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400 Publication 100-TD015B-EN-P - May 2015 Supersedes Publication 100-TD015A-EN-P September 2014 Copyright © 2015 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.