IEC Starter Approximate Dimensions

Technical Data
IEC Starter Approximate Dimensions
Bulletin Numbers 103H/107H/140M, 103-C/107/C, 105, 109, 106, 112, 113, 190E/191E, 190S/191S, 103S/107S, 103T/107T
Topic
Page
Enclosed Starters and Motor Protectors
35
103H/107H/140M Enclosed Combination Starters and Motor Protectors
35
Plastic Lift-off Enclosures
37
Metal Lift-Off and Hinged Enclosures
Open Starters
42
35
Starters with Eutectic Alloy Overload Relay
35
Bulletin 103S/107S Combination Starters
36
Additional Resources
These documents contain additional information concerning related products from Rockwell Automation.
Resource
Description
Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1
Provides general guidelines for installing a Rockwell Automation industrial system.
Product Certifications website, http://www.ab.com
Provides declarations of conformity, certificates, and other certification details.
You can view or download publications at http://www.rockwellautomation.com/literature/. To order paper copies of
technical documentation, contact your local Allen-Bradley distributor or Rockwell Automation sales representative.
IEC Starter Approximate Dimensions
Notes:
2
Rockwell Automation Publication 100-TD015B-EN-P - May 2015
Enclosed Starters and Motor Protectors
Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes
103H/107H/140M Enclosed Combination Starters
and Motor Protectors
Figure 8 - Enclosure Style A
Figure 9 - Enclosure Style B
Rockwell Automation Publication 100-TD015B-EN-P - May 2015
35
Figure 10 - Enclosure Style C
36
Rockwell Automation Publication 100-TD015B-EN-P - May 2015
Plastic Lift-off Enclosures
Bulletin 109 Plastic Lift-Off Enclosure
Figure 11 - Cat. Nos. 198E-A0S1, -C0S1, -C0S4
207.9
(8.19)
188
(7.41)
25.2
(0.99)
5.5
(0.22)
97.9
(3.86)
111
(4.37)
Rockwell Automation Publication 100-TD015B-EN-P - May 2015
37
Figure 12 - Cat. No. 198E-C0S4R
125 [4.93]
125 [4.93]
235 [9.26]
13 [0.51]
250 [9.85]
16
[0.63]
3.5 [0.14]
100 [3.94]
111.5 [4.39]
Ø23
[Ø0.91]
30 [1.18]
50 [1.97]
110 [4.33]
88.6 [3.49]
125 [4.93]
28.1 [1.11]
50 [1.97]
50 [1.97]
24 [0.95]
Rotary operator alternatively
(for maintained control)
10
Pozidriv No. 2
Pozidriv No. 2
(1.2 x 6.5)
2.0 Nm
18 lb-in
38
2 x 1...6 mm²
2 x No. 14...10 AWG
Rockwell Automation Publication 100-TD015B-EN-P - May 2015
2.3 Nm
20 lb-in
Figure 13 - Cat. No. 198E-C2S4
125 [4.93]
125 [4.93]
16 [0.63]
3.5
[0.14]
235 [9.26]
113.6 [4.48]
13 [0.51]
30 [1.18]
50 [1.97]
110 [4.33]
78 [3.07]
125 [4.93]
50 [1.97]
24 [0.95]
Rotary operator alternatively
(for maintained control)
28.1 [1.11]
50 [1.97]
169 [6.66]
250 [9.85]
Ø23
[Ø0.91]
10
Pozidriv No. 2
Pozidriv No. 2
(1.2 x 6.5)
2.0 Nm
18 lb-in
2 x 1...6 mm²
2 x No. 14...10 AWG
Rockwell Automation Publication 100-TD015B-EN-P - May 2015
2.3 Nm
20 lb-in
39
103C/107C Plastic Lift-Off Enclosure
Figure 14 - Cat. No. 198E-C0C4R
3.5
[0.14]
235 [9.26]
Ø15
[Ø0.59]
32.5 [1.28]
13 [0.51]
Ø3.5
[Ø0.14]
125 [4.93]
Ø23
[Ø0.91]
14.1
[0.56]
14.1
[0.56]
150 [5.91]
14.1 [0.56]
159.3 [6.28]
250 [9.85]
14.1 [0.56]
125 [4.93]
38.7 [1.52]
50 [1.97]
110 [4.33]
95 [3.74]
125 [4.93]
28.1 [1.11]
50 [1.97]
50 [1.97]
24 [0.95]
Rotary operator alternatively
(for maintained control)
10
Pozidriv No. 2
Pozidriv No. 2
(1.2 x 6.5)
2.0 Nm
18 lb-in
40
2 x 1...6 mm²
2 x No. 14...10 AWG
Rockwell Automation Publication 100-TD015B-EN-P - May 2015
2.3 Nm
20 lb-in
105C Plastic Lift-Off Enclosure
Figure 15 - Cat. No. 198E-C0S4R
125 [4.93]
125 [4.93]
235 [9.26]
13 [0.51]
3.5 [0.14]
111.5 [4.39]
Ø23
[Ø0.91]
100 [3.94]
30 [1.18]
50 [1.97]
110 [4.33]
88.6 [3.49]
50 [1.97]
24 [0.95]
Rotary operator alternatively
(for maintained control)
125 [4.93]
28.1 [1.11]
50 [1.97]
250 [9.85]
16
[0.63]
10
Pozidriv No. 2
Pozidriv No. 2
(1.2 x 6.5)
2.0 Nm
18 lb-in
2 x 1...6 mm²
2 x No. 14...10 AWG
Rockwell Automation Publication 100-TD015B-EN-P - May 2015
2.3 Nm
20 lb-in
41
Metal Lift-Off and Hinged Enclosures
Bulletin 109 Metal Lift-Off Enclosures, Type 1 (IP42)
Figure 16 - 109 Metal Lift-off Enclosures
23.4
(0.921)
B
D
A
F
Contactor Size
C09…C23
C30…C55
C60…C72
C85
C09…C23
C30…C55
C60…C72
C85
42
C
E
7.1 (0.28) dia.
For 1/4 in. or M6 Screw
3 mtg. holes
A Height
B Width
C Depth
D
E
IP42 (Type 1) General Purpose Metal Lift-Off Enclosure for Bulletin 109 (Without Transformer)
328 (12.91)
187 (7.35)
140 (5.52)
277 (10.75)
133 (5.24)
305 (12)
178 (7)
203 (8)
270 (10-5/8)
140 (5-33/64)
585 (23-1/32)
257 (10-7/64)
203 (8)
540 (21-17/64)
210 (8-17/64)
IP42 (Type 1) General Purpose Metal Lift-Off Enclosure for Bulletin 109 (With Transformer)
F
27(1.06)
24 (15/16)
23.5 (59/64)
328 (12.91)
187 (7.35)
140 (5.52)
277 (10.75)
133 (5.24)
27(1.06)
315 (12-27/64)
585 (23-1/32)
325 (12-51/64)
257 (10-7/64)
203 (8)
203 (8)
270 (10-5/8)
540 (21-17/64)
280 (11-1/64)
210 (8-17/64)
22.5 (57/64)
23.5 (59/64)
Rockwell Automation Publication 100-TD015B-EN-P - May 2015
105 Metal Lift-Off Enclosures Type 1 (IP42)
Figure 17 - 105 Metal Lift-Off Enclosure
23.4
(0.921)
B
D
A
F
Contactor Size
A Height
C09…C37
C43
C60…C72
C85
328 (12.91)
290 (11-27/64)
315 (12-27/64)
610 (24)
C09…C23
C30…C43
290 (11-27/64)
315 (12-27/64)
C
E
7.1 (0.28) dia.
For 1/4 in. or M6 Screw
3 mtg. holes
B Width
C Depth
D
E
F
IP42 (Type 1) General Purpose Metal Lift-off Enclosure for Bulletin 105 (Without Transformer)
187 (7.36)
140 (5.52)
273 (10.75)
133 (5.24)
27 (1.06)
270 (10-5/8)
152 (5-31/32)
245 (9-41/32)
225 (8-55/64)
22.5 (57/64)
325 (12-51/64)
203 (8)
270 (10-5/8)
280 (11-1/64)
22.5 (57/64)
406 (16)
230 (9-1/16)
572 (22-1/2)
368 (14-1/2)
19 (3/4)
IP42 (Type 1) General Purpose Metal Lift-Off Enclosure for Bulletin 105 (With Transformer)
270 (10-5/8)
152 (5-31/32)
245 (9-41/64)
225 (8-55/64)
22.5 (57/64)
325 (12-51/64)
203 (8)
270 (10-5/8)
280 (11-1/64)
22.5 (57/64)
Rockwell Automation Publication 100-TD015B-EN-P - May 2015
G (diameter)
—
—
—
11 (7-16)
—
—
43
106, 112, and 113 Metal Hinged Enclosures Type 1 (IP42), Type 3/4/12 (IP66)
Figure 18 - 106, 112, and 113 Metal Hinged Enclosures
Contactor Size
C09…C43
C60…C72
C09…C23
C30…C43
C60…C72
C30…C72
A Height
B Width
C Depth
D
E
F
IP42 (Type 1) and IP66 (Type 3/4/12) General Purpose Metal Hinged Enclosure for Bulletin 106 (With and Without Transformer)
350 (13-25/32)
400 (15-3/4)
200 (7-7/8)
315 (12-13/32)
178 (7)
62 (2-7/16)
610 (24)
406 (16)
224 (8-13/16)
572 (22-1/2)
368 (14-1/2)
19 (3/4)
IP42 (Type 1) and IP66 (Type 3/4/12) General Purpose Metal Hinged Enclosure for Bulletin 112 (With and Without Transformer)
350 (13-25/32)
200 (7-7/8)
200 (7-7/8)
315 (12-13/32)
76 (3)
62 (2-7/16)
350 (13-25/32)
400 (15-3/4)
200 (7-7/8)
315 (12-13/32)
178 (7)
111 (4-3/8)
610 (24)
406 (16)
224 (8-13/16)
572 (22-1/2)
368 (14-1/2)
19 (3/4)
IP42 (Type 1) and IP66 (Type 3/4/12) General Purpose Metal Hinged Enclosure for Bulletin 113 (With and Without Transformer)
610 (24)
406 (16)
224 (8-13/16)
572 (22-1/2)
368 (14-1/2)
19 (3/4)
G (diameter)
6.4 (1/4)
12.7 (1/2)
6.4 (1/4)
6.4 (1/4)
12.7 (1/2)
12.7 (1/2)
109 Metal Hinged Enclosures Type 3/4/12 (IP66)
Figure 19 - 109 Metal Hinged Enclosures
Contactor Size
A Height
C09…C43
C60…C72
C85
300 (11-13/16)
350 (13/25/32)
762 (30)
C09…C23
C30…C43
C60…C72
C85
300 (11-13/16)
300 (11-13/16)
350 (13-25/32)
610 (24)
44
B Width
C Depth
D
E
IP66 (Type 3/4/12) Metal Hinged Enclosure for Bulletin 109 (Without Transformer)
200 (7-7/8)
160 (6-5/16)
265 (10-7/16)
76 (3)
200 (7-7/8)
210 (8-9/32)
315 (12-13/32)
76 (3)
305 (12)
276 (10-7/8)
724 (28-1/2)
267 (10-1/2)
IP66 (Type 3/4/12) Metal Hinged Enclosure for Bulletin 109 (With Transformer)
200 (7-7/8)
160 (6-5/16)
265 (10-7/16)
76 (3)
300 (11-13/16)
160 (6-5/16)
236 (9-5/16)
178 (7)
400 (15-3/4)
210 (8-9/32)
315 (12-13/32)
178 (7)
406 (16)
230 (9-1/16)
572 (22-1/2)
368 (14-1/2)
Rockwell Automation Publication 100-TD015B-EN-P - May 2015
F
G (diameter)
62 (2-7/16)
62 (2-7/16)
19 (3/4)
5.5 (7/32)
5.5 (7/32)
11 (7/16)
62 (2-7/16)
61 (2-13/32)
111 (4-3/8)
19 (3/4)
5.5 (7/32)
5.5 (7/32)
5.5 (7/32)
11 (7/16)
105 Metal Hinged Enclosures Type 3/4/12 (IP66)
Figure 20 - 105 Metal Hinged Enclosures
Contactor Size
A Height
C09…C23
C30…C43
C60…C72
C85
250 (9-13/16)
300 (11-13/16)
350 (13/25/32)
610 (24)
C09…C23
C30…C43
C60…C72
C85
300 (11-13/16)
350 (13-25/32)
610 (24)
762 (30)
B Width
C Depth
D
E
IP66 (Type 3/4/12) Metal Hinged Enclosure for Bulletin 105 (Without Transformer)
250 (9-13/16)
160 (6-5/16)
186 (7-5/16)
76 (3)
300 (11-13/16)
160 (6-5/16)
178 (7)
400 (15-3/4)
210 (8-9/32)
315 (12-13/32)
178 (7)
406 (16)
230 (9-1/16)
572 (22-1/2)
368 (14-1/2)
IP66 (Type 3/4/12) Metal Hinged Enclosure for Bulletin 105 (With Transformer)
200 (7-7/8)
160 (6-5/16)
236 (9-5/16)
178 (7)
400 (15-3/4)
210 (8-9/32)
315 (12-13/32)
178 (7)
406 (16)
230 (9-1/16)
572 (22-1/2)
368 (14-1/2)
610 (24)
281 (11-1/16)
724 (28-1/2)
572 (22-1/2)
Rockwell Automation Publication 100-TD015B-EN-P - May 2015
F
G (diameter)
87 (3-13/32)
61 (2-13/32)
111 (4-3/8)
19 (3/4)
5.5 (7/32)
5.5 (7/32)
5.5 (7/32)
11 (7/16)
61 (2-13/32)
111 (4-3/8)
19 (3/4)
19 (3/4)
5.5 (7/32)
5.5 (7/32)
11 (7/16)
11 (7/16)
45
46
Rockwell Automation Publication 100-TD015B-EN-P - May 2015
Open Starters
Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes
Starters with Eutectic Alloy Overload Relay
Figure 8 - 105 and 109 Open Style Starters
G
Starter
Current
Rating [A]
9…23
30
109,
37…43
AC or DC voltage
60
72
9…23
30
105,
37…43
AC or DC voltage
60
72
Starter Type
A Height
B Width
C Depth
D
E
F
G (diameter)
H
202.4 (7-63/64)
247.6 (9-3/4)
247.6 (9-3/4)
323.9 (12-3/4)
323.9 (12-3/4)
202.4 (7-63/64)
247.6 (9-3/4)
247.6 (9-3/4)
323.9 (12-3/4)
323.9 (12-3/4)
69.8 (2-3/4)
88.9 (3-1/2)
88.9 (3-1/2)
127 (5)
137.6 (5-27/64)
120.6 (4-3/4)
152.4 (6)
152.4 (6)
241.3 (9-1/2)
251.9 (9-15/16)
98.4 (3-57/64)
110.8 (4-23/64)
120.8 (4-3/4)
133.1 (5-15/16)
133.1 (5-15/16)
98.4 (3-57/64)
110.8 (4-23/64)
120.8 (4-3/4)
133.1 (5-15/16)
133.1 (5-15/16)
190.5 (7-1/2)
235.7 (9-9/32)
235.7 (9-9/32)
308.1 (12-9/64)
308.1 (12-9/64)
190.5 (7-1/2)
235.7 (9-9/32)
235.7 (9-9/32)
308.1 (12-9/64)
308.1 (12-9/64)
5.08 (2)
69.8 (2-3/4)
69.8 (2-3/4)
101.6 (4)
101.6 (4)
101.6 (4)
133.3 (5-1/4)
133.3 (5-1/4)
215.9 (8-1/2)
215.9 (8-1/2)
9.5 (25/64)
9.5 (25/64)
9.5 (25/64)
12.7 (1-1/2)
12.7 (1-1/2)
9.5 (25/64)
9.5 (25/64)
9.5 (25/64)
12.7 (1-1/2)
12.7 (1-1/2)
34.9 (1-25/64)
44.4 (1-3/4)
—
—
—
60.4 (2-25/64)
76.2 (3)
76.2 (3)
—
—
—
—
76.2 (3)
101.6 (4)
101.6 (4)
—
—
—
215.9 (8-1/2)
215.9 (8-1/2)
Rockwell Automation Publication 100-TD015B-EN-P - May 2015
35
Bulletin 103S/107S Combination Starters
Standard and ISO Busbar Mount — Bulletin 103S Non-Reversing and 107S Reversing
Starters
(a) With additional side-mount aux. or trip contact(s)
(b) Standard busbar mount with control plug
(c) Iso busbar mount
(d) Electronic interface
9 (d)
244 (b) / 249 (c)
65 (b) / 70 (c)
105
9 (d)
213 (b) / 218 (c)
60
60
12...30
205.5 (b) / 210.5 (c)
97.5
9 (d)
236.5 (b) / 241.5 (c)
65 (b) / 70 (c)
34 (b)
39 (c)
31
34 (b)
39 (c)
60
60
12...30
36
(a) With additional side-mount aux. or trip contact
(b) Standard busbar mount with control plug
(c) Iso busbar mount
(d) Electronic interface
Circuit Breaker: 140M-F
Contactor:
100-C30...37
Reference Print: D10GMF
54
Circuit Breaker: 140M-D
Contactor:
100-C30...37
Reference Print: D10GMD
63 (a)
54
31
Circuit Breaker: 140M-C / -D
Contactor:
100-C09...23
Reference Print: D00GMD
244 (b) / 249 (c)
65 (b) / 70 (c)
105
60
12...30
54 (a)
45
213 (b) / 218 (c)
60
236.5 (b) / 241.5 (c)
97.5
12...30
9 (d)
60
205.5 (b) / 210.5 (c)
60
34 (b)
39 (c)
65 (b) / 70 (c)
34 (b)
39 (c)
31
31
Figure 9 - 103S Busbar Mount
63
(b) Standard busbar mount with control plug Circuit Breaker: 140M-F
(c) Iso busbar mount
Contactor:
100-C43
(d) Electronic interface
Reference Print: D20GMF
Rockwell Automation Publication 100-TD015B-EN-P - May 2015
(b) Standard busbar mount with control plug
(c) Iso busbar mount
(d) Electronic interface
213 (b) / 218 (c)
105
117 (a)
(a) With additional side-mount aux. contacts
(b) Standard busbar mount with control plug
(c) Iso busbar mount
(d) Electronic interfaces
(a) With additional side-mount aux. contacts
(b) Standard busbar mount with control plug
(c) Iso busbar mount
(d) Electronic interface
Circuit Breaker: 140M-F
Contactors:
100-C30...37
Reference Print: R10GMF
105
213 (b) / 218 (c)
244 (b) / 249 (c)
65 (b) / 70 (c)
60
117
135 (a)
(a) With additional side-mount aux. contacts
(b) Standard busbar mount with control plug
(c) Iso busbar mount
(d) Electronic interface
Circuit Breaker: 140M-F
Contactors:
100-C43
Reference Print: R20GMF
Rockwell Automation Publication 100-TD015B-EN-P - May 2015
9 (d)
99
117 (a)
9 (d)
12...30
60
236.5 (b) / 241.5 (c)
205.5 (b) / 210.5 (c)
12...30
60
97.5
60
34 (b)
39 (c)
65 (b) / 70 (c)
34 (b)
39 (c)
31
31
Circuit Breaker: 140M-D
Contactors:
100-C09...23
Reference Print: R00GMD
Circuit Breaker: 140M-D
Contactors:
100-C30...37
Reference Print: R10GMD
244 (b) / 249 (c)
65 (b) / 70 (c)
34 (b)
39 (c)
60
99
9 (d)
99
117 (a)
9 (d)
12...30
60
236.5 (b) / 241.5 (c)
205.5 (b) / 210.5 (c)
12...30
60
97.5
60
65 (b) / 70 (c)
34 (b)
39 (c)
31
31
Figure 10 - 107S Busbar Mount
(a) With additional side-mount aux. contacts
(b) Standard busbar mount with control plug
(c) Iso busbar mount
(d) Electronic interface
37
Panel Mount — 103S Non-Reversing and 107S Reversing Starters
Figure 11 - 103S Panel Mount
31 (b)
40
40 (a)
228
125
210
228
125
31 (b)
31 (b)
210
97.5
105
69
64
69
64
31 (b)
35
54 (a)
45
Circuit Breaker: 140M-C/D
Contactor:
100-C09...23
Reference Print: D00WMD
(a) With additional side-mount aux. or trip contact(s)
(b) Control plug on top OR bottom side optional
54
Circuit Breaker: 140M-F
Contactor:
100-C30...37
Reference Print: D10WMF
(a) With additional side-mount aux. or trip contact
(b) Control plug on top OR bottom side optional
40
228
69
125
210
31 (b)
31 (b)
125
228
105
64
69
210
97.5
64
31 (b)
31 (b)
40
63
54
Circuit Breaker: 140M-D
Contactor:
100-C30...37
Reference Print: D10WMD
38
(b) Control plug on top OR bottom side optional
Circuit Breaker: 140M-F
Contactor:
100-C43
Reference Print: D20WMF
Rockwell Automation Publication 100-TD015B-EN-P - May 2015
(a) With additional side-mount aux. or trip contact
(b) Control plug on top OR bottom side optional
Figure 12 - 107S Panel Mount
87
64
228
31 (b)
31 (b)
125
105
125
210
69
64
228
69
97.5
210
31 (b)
31 (b)
87
99
99
117 (a)
117 (a)
Circuit Breaker: 140M-C/D
Contactors:
100-C09...23
Reference Print: R00WMD
(a) With additional side-mount aux. contacts
(b) Control plug on top OR bottom side optional
Circuit Breaker: 140M-F
Contactors:
100-C30...37
Reference Print: R10WMF
(a) With additional side-mount aux. contacts
(b) Control plug on top OR bottom side optional
103
228
69
31 (b)
125
105
31 (b)
125
210
64
228
69
210
97.5
64
31 (b)
31 (b)
87
117
99
135 (a)
117 (a)
Circuit Breaker: 140M-D
Contactors:
100-C30...37
Reference Print: R10WMD
(a) With additional side-mount aux. contacts
(b) Control plug on top OR bottom side optional
Circuit Breaker: 140M-F
Contactors:
100-C43
Reference Print: R20WMF
Rockwell Automation Publication 100-TD015B-EN-P - May 2015
(a) With additional side-mount aux. contacts
(b) Control plug on top OR bottom side optional
39
Figure 13 - Cat. No. 140M-C-TE1 Type E adapter on Cat. No. 140M-C2E…
Figure 14 - Cat. No. 140M-C-TE1 Type E adapter on Cat. No. 140M-D8E…
Figure 15 - Cat. No. 140M-C-TE1 Type E adapter on Cat. No. 140M-F8E…
40
Rockwell Automation Publication 100-TD015B-EN-P - May 2015
Figure 16 - Screw Adapter 140M-C-N45 for 140M-C2/D8 and 140M-F8
.
.
.
Figure 17 - Cat. No. 140M-C with Busbar
§
Compact Busbar Feeder Terminal IEC
Compact Busbar Feeder Terminal UL type E and IEC
Mounting on 35 mm DIN Rail
§ Top Hat Rail Adapter 10 mm
Rockwell Automation Publication 100-TD015B-EN-P - May 2015
41
Figure 18 - 140M-C-SHS Screw Adapter
> 10 (25/64)
205 (8-5/64)
140M-C
215 (8-31/64)
140M-D / 140U-D
245 (9-41/64)
140M-F
Figure 19 - 140M-C-D…66
4.5
(0.18)
min. 100
(3.93)
3.5
(0.14)
1.5...5
0.06…0.19)
35...45
(1.4…1.8)
b
53.5
(2.10)
53.5
(2.10)
140M-C-DS
140M-C-DSL
a
±5
(0.19)
4...8
(0.16…0.31)
c1
±5
(0.19)
4.5
(0.18) c2
2.4
(0.09)
Cat. No.
140M-C
140M-D
140M-F
42
With Cat. No. 140-M-C-DS Shaft
a
b
117…338
105.5 ±5
126…347
114.5 ±5
148.6…369.6
137.1 ±5
c1
49.5
49.5
59.35
c2
40.5
40.5
50.35
a
117…438
126…497
148.6…519
With Cat. No. 140-M-C-DSL Shaft
b
c1
105.5 ±5
49.5
114.5 ±5
49.5
137.1 ±5
59.35
Rockwell Automation Publication 100-TD015B-EN-P - May 2015
c2
40.5
40.5
50.35
Figure 20 - 140M-C-WBE
Figure 21 - Cat. No. 198E…
Ø
Ø
Ø
Rockwell Automation Publication 100-TD015B-EN-P - May 2015
43
Figure 22 - 140-CMN
Figure 23 - 140-CD…
1.5…5
(0.059…0.197)
5 (0.197)
min. 100
(3.94)
3.5 (1.38)
3.5…4.5 (1.38…1.77)
±5 (0.197)
169
(6.65)
53.5
(2.10)
180…402
(7.09…50.83)
53.5
(2.10)
±5 (0.197)
4…8
(0.157…0.314)
44
Rockwell Automation Publication 100-TD015B-EN-P - May 2015
Figure 24 - Mounting position/safety clearance of Cat. No. 140-CMN
70
(2.75)
90
°
90
°
°
90
30°
70
(2.75)
Rockwell Automation Publication 100-TD015B-EN-P - May 2015
45
46
Rockwell Automation Publication 100-TD015B-EN-P - May 2015
IEC Starter Approximate Dimensions
Rockwell Automation Publication 100-TD015B-EN-P - May 2015
1
Important User Information
Read this document and the documents listed in the additional resources section about installation, configuration, and
operation of this equipment before you install, configure, operate, or maintain this product. Users are required to
familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws,
and standards.
Activities including installation, adjustments, putting into service, use, assembly, disassembly, and maintenance are required
to be carried out by suitably trained personnel in accordance with applicable code of practice.
If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be
impaired.
In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the
use or application of this equipment.
The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and
requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or
liability for actual use based on the examples and diagrams.
No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or
software described in this manual.
Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation,
Inc., is prohibited.
Documentation Feedback
Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this
document, complete this form, publication RA-DU002, available at http://www.rockwellautomation.com/literature/.
Allen-Bradley, Rockwell Software, Rockwell Automation, and LISTEN. THINK. SOLVE are trademarks of Rockwell Automation, Inc.
Trademarks not belonging to Rockwell Automation are property of their respective companies.
Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400
Publication 100-TD015B-EN-P - May 2015
Supersedes Publication 100-TD015A-EN-P September 2014
Copyright © 2015 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.