Fire-resistant mortise door locks. Fire-resistant mortise door locks and accessories. nemef.com ASSA ABLOY, the global leader in door opening solutions Fire-resistant mortise door locks. Nemef guarantees an extensive and continually growing assortment of locks and builders’ hardware, such as door locks, profile cylinders, multi-point locks and access control. These quality products that leave the Nemef plant reach their customers quickly and efficiently due to a hypermodern distribution centre in the Netherlands. Nemef is working today on the standard for tomorrow through innovative product development focused on contemporary user convenience. Within this brochure we give an overview of our fire resistant mortise door locks and accessories. Information Page Information about locks 5 EN Standards Overview of the European standards for building hardware 1730 Serie Fire-resistant mortise locks 15 1759 Serie (non fire-resistant) Special mortise locks 16 1769 Serie 17 1769/88 and 699 Fire-resistant mortise locks Self-closing panic locks 1729 and 1723 Serie Fire-resistant mortise multi-point locks 22 1749 and 1742 Serie Fire-resistant mortise multi-point locks 24 1900 Serie Fire-resistant panic mortise locks for one and two leaf doors 26 3600 Serie Panic bar ‘Smart’ 28 9670/08 Fire-resistant narrow-style panic locks 31 Accessories 1900 and 3600 Series 32 2900 Serie Fire-resistant door handles 34 1012 Serie Fire-resistant door hinges 39 Fire resistant plates Fire resistant plates 40 Strike plates Strike plates 41 Accessories Accessories 42 Certificates Certificates ISO 9001, EN 179 and EN 1125 43 7 20 In the future we’ll also meet the demands for technical advances and innovations. We therefore reserve the right to make design modifications. Illustrations may thus also vary from the actual products. Despite the greatest of care, printing errors or mistakes may be made. Nemef accepts no responsibility in such cases and will not enter into any obligations of any kind. No responsibility is taken for the correctness of any safety regulations reproduced. 3 4 Information about locks. Do not fix a knob profile cylinder in lock of panic doors. Do not paint front, dead- and latch bolt. Do not leave a key in the lock of panic locks. Do not fit the square spindle with force. If door furniture is not fixed do not throw dead bolt. Locks must be replaced when signs of damage are obvious. Do not force door trim. Do not drill through lockcases. International Situation Symbols DIN Left (1) DIN Right (2) DIN Left (3) DIN Right (4) inside inside outside outside 5 6 Overview of the European EN Standards for building hardware. What are the advantages of an EN-tested product? • Resistance/reliability. • Durability. • Safety. • Ease-of-use. • Guaranteed operability. • Dimensions. • Mechanical resistance. Where do the standards apply? In public buildings • Hospital. • Shopping centre. • Station. • Airport. In private buildings • Apartment block. • Office. EN 179 • Emergency exit devices operated by a lever handle or push pad, for use on escape routes. • Requirements and test methods. EN 1125 • Panic exit devices operated by a horizontal bar, for use on escape routes. • Requirements and test methods. EN 12209 • Locks and latches. • Mechanically operated locks, latches and locking plates. • Requirements and test methods. EN 1935 DIN 18250 Fire-resistant door hinges. Mortise locks for fire- and smoke resistant doors. DIN 18273 Doorhandles for fire- and smoke resistant doors. CE marking Mechanically operated locks, latches and panic and emergency exit devices intended for use on fire/ smoke control doors within the European Economic Area are covered by Construction Products Directive mandate issued by the European Commission. Consequently, this standard is regarded as “harmonised” and compliance with it, supported by suitable evidence, allows for the application of the CE mark. 7 EN 179 Emergency exit devices operated by a lever handle or push pad, for use on escape routes - Requirements and test methods. Use Emergency situations where the occupants know the building, its escape routes and emergency exits and where panic situations are hardly to be expected; for example, in offices or apartment blocks. Door weight • Operation tested between -10°C and +60°C. • U-shaped lever on the inside in order to minimise the risk of injury, and a minimum length of 120 mm (measured from the centre of the lever pivot pin to the extreme edge of the lever). • Protrusion of the operating element: - maximum of 150 mm in category 1. - maximum of 100 mm in category 2. •The exterior means of operation (key, cylinder, lever handle or knob) must be approved by the manufacturer of the emergency exit device. •The force required to unlock an emergency exit device with a lever handle => less than 70 N. •The force required to unlock an emergency exit device with a push pad (also known as pushing force) => less than 150 N. • Durability: - 100,000 test cycles for grade 6. - 200,000 test cycles for grade 7. Durability Specifications for the locking mechanism for emergency exits in accordance with the EN 179 standard Category of use The emergency exit devices in accordance with standard EN 179 are intended to ensure a safe and efficient escape route via an emergency exit door that can be opened with one simple action. 1 2 3 100,000 test cycles. 6 200,000 test cycles. 7 3 High frequency of use by the public and others, where the situation may lead to rough use. 8 up to 100 kg. 5 up to 200 kg. 6 >200 kg. 7 Classification EN 179: 2008. Security Operating element Type of operation Application • Mechanical locks with a panic function and automatic locking. Lock types: e.g. Art. 1769/36, 1769/46 and 1769/88. Corrosion resistance Nemef products that comply with the EN 179 standard Safety The EN 179 standard uses a 10 digit code to classify the emergency exit facility. Fire resistance Classification 4 5 6 7 8 9 10 1 All exit devices for emergency exit doors have a critical safety function. This standard is specially intended for this. 0 Not suitable for use on fire doors and/or smoke containment doors. A Suitable for use on smoke containment doors (in accordance with the requirements specified in the standard). B Suitable for use on fire doors and smoke containment doors (according to EN 1634-1). 3 High. 4 Very high. 2 1000 N. 3 2000 N. 4 3000 N. 5 5000 N. Single-leaf or double-leaf door opening to the outside: active or passive leaf. 1 2 A Maximum projection of 150 mm. Single leaf door opening to the outside. B Passive leaf of double door that opens to the outside. C Single leaf door opening to the inside. D Maximum projection of 100 mm. Note: Additional requirements for tests for a higher level of safety may not lead to a reduction relative to the other requirements in this standard. A Door lever handle. B Door lever handle/push pad. 9 EN 1125 Panic exit devices operated by a horizontal bar, for use on escape routes Requirements and test methods. Panic exit devices are available as complete facefit units or as face fit units in combination with a mortise lock. The exterior face to exterior face dimension of a panic exit device must match the total door width as accurately as possible, but may never be less than 60% of the total door width. Specifications for the locking mechanism for emergency exits in accordance with the EN 1125 standard. 10 • Operation tested between -10°C and +60°C. •All sharp edges must be rounded to a minimum radius of 0.5 mm. •The distance between the bar and the door leaf surface may not be less than 25mm. • Protrusion of the operating element: - maximum of 150 mm in category 1. - maximum of 100mm in category 2. •The exterior means of operation (key, cylinder, lever handle or knob) must be approved by the manufacturer of the panic exit device. •The force required for unlatching a panic exit device in a situation where the door is not under load => less than 80 N. •The force required for unlatching a panic exit device in a situation where the door is under load => less than 220 N. • Durability: - 100,000 test cycles for grade 6. - 200,000 test cycles for grade 7. Door weight Consequently, it offers a safe way of escaping the building even when the door is subjected to load (i.e. even when a person pushes against the door and not on the bar, one should still be able to open the door by pressing the panic bar). The panic exit devices are opened by a horizontal bar. There are two types: - Type A, panic exit devices with a push bar: the bar moves through an arc in the downward direction. - Type B, panic exit devices with a touch bar: this is a bar which is pushed in the direction of opening. Durability A panic exit device (also called panic hardware) is used to allow operation of an emergency exit door in a safe, secure and efficient way, with a minimal force and without prior knowledge of the system. A panic exit device in accordance with the EN 1125 standard is used where a large number of people can be expected who, in an emergency situation, are neither familiar with the escape routes nor the escape provisions. Category of use Use 1 2 3 100,000 test cycles. 6 200,000 test cycles. 7 3 High frequency of use by the public and others, where the situation may lead to rough use. Up to 100 kg. 5 Up to 200 kg. 6 >200 kg. 7 Classification EN 1125: 2008. Classification The EN 1125 standard uses a 10 digit code to classify the emergency exit facility. Nemef products that comply with the EN 1125 standard All face-fit panic bar exit devices in the Nemef range comply with the EN 1125 standard. Fire resistance Safety Corrosion resistance Security Operating element Operation type Application The panic bar exit devices with integral lock (tested together) that comply with the EN 1125 standard are: Lock types: e.g. Art. 1901 and 1921. On condition that the exit can always be used via the lever handle on the inside, the norm does not allow monitoring of the exit. 4 5 6 7 8 9 10 The horizontal push rod/bar can withstand a force of 1000 N (100 kg). 1 All exit devices for emergency exit doors have a critical safety function. This standard is specially intended for this. 2 1 2 0 Not suitable for use on fire doors and/or smoke containment doors. A Suitable for use on smoke containment doors (in accordance with the requirements specified in the standard). B Suitable for use on fire doors and smoke containment doors (according to EN 1634-1). 3 High (96 hour salt spray test). 4 Very high (240 hour salt spray test). Single-leaf or double-leaf door: active or passive leaf. A Single-leaf door. B Passive leaf of a double door. C Maximum projection of 150mm. Maximum projection of 100 mm. Note: Additional requirements for tests for a higher level of safety may not lead to a reduction relative to the other requirements in this standard. A Push rod. B Push bar. 11 Specifications for the locking mechanism for emergency exits in accordance with the EN 12209 standard. • Operation tested between -20°C and +80°C. •Category of use: - Grade 1: average frequency of use, very careful users => private use. - Grade 2: high frequency of use, careful users => interior doors in offices. - Grade 3: very high frequency of use, high probability of abuse => offices in public buildings. •Durability: in accordance with the cycles and load on the day latch. •Fire resistance: - Grade 0: not CF-approved. - Grade 1: CF-approved. • Safety. • Corrosion resistance. • Security. Door weight and closing force This European standard specifies the requirements and test methods for durability, resistance, security, operation of the mechanical locks and their locking plates in accordance with the usage profile for the door. The correct grade must be chosen in line with the usage profile. Durability and load on the day latch Use Category of use EN 12209 Locks and latches - Mechanically operated locks, latches and locking plates Requirements and test methods. 1 2 3 A 50,000 cycles, no load. 1 Up to 100 kg, 50 N maximum. B 100,000 cycles, no load. 2 Up to 200 kg, 50 N maximum. C 200,000 cycles, no load. 3 More than 200 kg or as indicated, 50 N maximum. F 50,000 cycles, 10 N load. 4 Up to 100 kg, 25 N maximum. G 100,000 cycles, 10 N load. 5 Up to 200 kg, 25 N maximum. More than 200 kg or as indicated, 25 N maximum. Classification The EN 12209 standard uses an 11 digit code to classify the mechanical locks. H 200,000 cycles, 10 N load. 6 Nemef products that comply with the EN 12209 standard Mechanical locks with a panic function and automatic locking. L 100,000 cycles, 25 N load. 7 Up to 100 kg, 15 N maximum. M 200,000 cycles, 25 N load. 8 Up to 200 kg, 15 N maximum. R 100,000 cycles, 50 N load. 9 More than 200 kg or as indicated, 15 N maximum. S 200,000 cycles, 50 N load. W 100,000 cycles, 120 N load. X 200,000 cycles, 120 N load. 12 1 Low risk of abuse, very careful users =>PRIVATE USE. 2 Risk of abuse, careful users =>Offices. 3 High frequency of use by the public, with a high risk of abuse => PUBLIC BUILDINGS. Fire resistance Safety Corrosion resistance and temperature resistance Security: resistance to attack using a drill Area of application of the door Type of key opening: latch mechanism Type of square shaft Identification of the key Classification EN 12209: 2003/AC: 2005. 4 5 6 7 8 9 10 11 0 0 1 No requirements Not suitable for use on fire doors and/or smoke containment doors. Suitable for use on fire doors and/ or smoke containment doors. 0 No requirements. 1 Minimal; no resistance. A Mortise lock; without limitation on the application. 0 Not applicable. A Low resistance; no requirements. 2 Weak; no resistance. B Mortise lock; hinged door. A B Average resistance; no requirements. 3 Average; no resistance. C Mortise lock; sliding door. C High resistance; no requirements. 4 High; no resistance. D D Very high resistance; no requirements. 5 High; with resistance. E Average resistance; between -20°C and +80°C. 6 F High resistance; between -20°C and +80°C. 7 G Very high resistance; between -20°C and +80°C. No requirements. 0 Cylinder lock; manual. At least 3 locking pins. A B Cylinder lock; automatic. At least 5 locking pins. B Face-fit lock; without limitation on the application. C Cylinder lock; manual with intermediary. At least 3 locking pins with an extensive number of combinations. C E Face-fit lock; hinged door. D Lever lock; manual. Very high; no resistance. F Face-fit lock; sliding door. E Lever lock; automatic. At least 6 locking pins. D Very high; with resistance. G Mortise lock; without limitation on the application. F Lever lock; manual with intermediary. At least 6 locking pins with an extensive number of combinations. E H Mortise lock; hinged door; supported. G Lock without key; manual. J Face-fit lock; hinged door, opening to the exterior. H Lock with night latch without key; automatic. At least 7 locking pins . F K Mortise lock; hinged door, latch on interior face. At least 7 locking pins with an extensive number of combinations. G L Mortise lock; sliding door, latch on interior face. At least 8 locking pins with an extensive number of combinations. H M Face-fit lock; hinged door, latch on interior face. N Face-fit lock; sliding door, latch on interior face. 0 Lock without lock shaft aperture. P Mortise lock; hinged door; supported, latch on interior face. 1 With knob or sprung lever. R Face-fit lock; hinged door, opening to the interior, latch on interior face. 2 With unsprung lever. 3 With unsprung lever for intensive use. 4 With sprung lever for intensive use indicated by the manufacturer. 13 14 1730 Series. Fire-resistant mortise locks Specifications • For European profile cylinder. • Key action on latch bolt. • Single throw dead bolt. • Non-handed. • Without strike plate. Profile cylinder 9 mm follower Steel, zinc-plated front plate 24 x 235 mm rounded Stainless steel front plate 24 x 235 mm rounded Steel, zinc-plated lock case Steel, zinc-plated latch bolt Zinc-plated roller bolt (adjustable) Steel, zinc-plated dead bolt Key action on latch bolt Single throw Panic one-piece follower Panic two-piece follower Zinc-plated security bolt 22 mm profile cylinder Packed per piece Packed per 25 pieces • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 1739/55 Distance 72 mm 1739/51 Backset 65 mm 1739/46 •Key-infill piece with set screw Art. BB 1739 and BB 7000 (Page 42). •Strike plate Art. P 1739/17 stainless steel and 1739/12 zinc-plated (page 41). • Reduction sleeve 8/9 mm Art. 1769/21 (page 42). 1739/36 Accessories 1739/29 Furniture with split spindle is required. In unlocked position, latch bolt is operated from both sides by lever handle/key action. In locked position, inside lever handle retracts latchand dead bolt simultaneously. Outside lever handle retracts latch bolt only. Dead bolt operated by cylinder key. 1739/28 Art. 1739/46 1739/27 Furniture with fixed knob outside is required. In unlocked position latch bolt retracts from the outside only by key action, from the inside by lever handle. In locked position lever handle retracts latch- and dead bolt simultaneously from inside (panic function). Bolts operated from outside by cylinder key only. 1739/03 Art. 1739/36 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Art. 1739 Standards: CE marking, EN 12209 and EN 179 (Panic) Art. 1739 15 1759 Series (non fire-resistant). Special mortise locks. Specifications • Non fire-resistant. • For European profile cylinder. • Key action on latch bolt. • Single throw dead bolt. • Non-handed. • Without strike plate. 1759/08 1759/08 KABA 1759/26 1759/29 For non fire-resistant steel doors (for example passage door in garage). 1759/06 Note 1759/02 KABA Strike plate Art. P1759/02 steel zinc plated (page 41). 1759/02 Accessories • • • • • • • • • • • 8 mm follower • • • • • • • • • • • • Steel, lacquered front plate 20 x 235 mm rounded RAL 7035 • • Backset 65 mm Distance 72 mm Profile cylinder • • • Steel, zinc-plated front plate 20 x 235 mm rounded Steel, zinc-plated front plate 20 x 325 mm rounded Hole 6.5 countersunk 11.25 x 90˚ • • • • • • • • • • • • • • • • Steel, zinc-plated lock case for multi-point Steel, zinc-plated lock case Die-cast, latch bolt • • • • • • • • • • • Latch bolt not centric in front plate Die-cast, dead bolt Key action on latch bolt Single throw 22 mm profile cylinder • • • • • • Handed Packed per piece Packed per 25 pieces 16 • • Art. 1759 Standards: none • • • • • • • • • • • • • • • • • • Art. 1759 1769 Series. Fire-resitant mortise locks. Specifications • For European profile cylinder. • Key action on latch bolt. • Double throw dead bolt. • Handed. • Without strike plate. Steel, zinc-plated front plate 24 x 235 mm rounded Stainless steel front plate 24 x 235 mm rounded Stainless steel front plate 20 x 235 mm rounded Steel, zinc-plated lock case Steel, zinc-plated latch bolt Steel, nickel-plated latch bolt Steel, zinc-plated dead bolt Steel, nickel-plated dead bolt Key action on latch bolt Double throw • • • • • • • • • • • • Panic two-piece follower Panic two-piece follower inwards Lever free Packed per 25 pieces • • 1769/36 • • • • • • • • • • • • • • • • 1769/35 • • • • • • • 1769/32 • • • • Panic one-piece follower Packed per piece 1769/26 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Latch only Dead bolt only 1769/25 1769/77 8 mm follower 1769/57 9 mm follower 1769/56 Profile cylinder 1769/48 Distance 72 mm 1769/46 Backset 65 mm 1769/24 Furniture with split spindle is required. In unlocked position, latch bolt is operated from both sides by lever handle/key action. In locked position, inside lever handle retracts latch- and dead bolt simultaneously (panic function D). Outside lever handle retracts latch bolt only. Dead bolt operated by cylinder key. 1769/23 Art.1769/46 1769/08 Furniture with fixed knob outside is required. In unlocked position latch bolt retracts from the outside only by key action, from the inside by lever handle. In locked position lever handle retracts latch- and dead bolt simultaneously from inside (panic function E). Bolts operated from outside by cylinder key only. 1769/03 Art.1769/36 • • • • • • • • • • • • • • • • • • • • • • • • • • • Art. 1769 Standards: CE marking, EN 12209, EN 1125, EN 179 (panic) and DIN 18250 T 120 (part 1) • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Accessories: 22 mm profile cylinder hole, strike plate Art. P 1769/66 zinc-plated (reversible) or Art. P 1769/17 stainless steel (handed) (page 41), reduction sleeve 8/9 mm Art. 1769/21 (page 42). Art. 1769/03 17 18 1769 Series - Class 5*. Fire-resistant mortise locks. Specifications • For fire-resistants doors. • To take profile cylinder. • Handed. • Backset 65 mm - distance 72 mm. • Key action on latch bolt. • Plastic latch for noise reduction. • Double throw Omega dead bolt. • Front plate available in 20/24 mm in aluminium finish or stainless steel. • Available with plastic dead bolt cap on request. • Without strike plate. Front plate 20 x 235 mm rounded Front plate 24 x 235 mm rounded 9 mm follower Aluminium finish or stainless steel Packed per 25 or 750 pieces 1769/02 1769/01 Art. 1769/01 and 1769/02 Standards: CE marking, EN 12209 and DIN 18250 T 120 (part 1) • • • • • • • • Art. 1769 * Class 5 according to DIN 18250 attachment 2. 19 1769/88 Self-closing Panic locks. Fire-resistant. Specifications • To take profile cylinder. • Handed. • Backset 65 mm - distance 72 mm. • Key action on latch bolt. • With auxiliary latch. • 9 mm bolt through follower. • Is fire-resistant and MPA registered. • Without strike plate. Attention Do not use these locks in combination with knob cylinder, electrical door opener nor lever/ lever handle. Accessories None. 1769/88 Art. 1769/88 Standards: EN 179 and DIN 18250 T 120 (part 1), MPA registered Backset 65 mm Stainless steel front plate 20 x 235 mm rounded Stainless steel front plate 24 x 235 mm rounded Packed per piece 20 • • • • Art. 1769/88 699 Self-closing Panic locks. Non fire-resistant. Specifications • To take profile cylinder. • Handed. • Backset 55 und 60 mm - distance 72 mm. • Key action on latch bolt. • With auxiliary latch. • 8 mm bolt through follower. • Including strike plate. Attention Do not use these locks in combination with knob cylinder, electrical door opener nor lever/ lever handle. Accessories None. Backset 55 mm Backset 60 mm Stainless steel front plate 20 x 235 mm rounded Stainless steel front plate 24 x 235 mm rounded Packed per piece • • • • • 699/35 699/34 699/31 699/30 Art. 699 Standards: EN 179 • • • • • • • Art. 699 21 1729 and 1723 Series. Fire-resistant mortise multi-point locks. 22 Main lock Art. 1729/21 Standards: none Upper lock Art. 1723/21 Standards: none Rod Art. 1729 Standards: none Lower lock Art. 1723/21 Standards: none 1729 and 1723 Series. Fire-resistant mortise multi-point locks. Specifications • Non-handed. • For European profile cylinder. • Key action on latch bolt. • Single throw dead bolt. • With rod movement up- and downwards. • Without strike plate. Latches Art. 1723/21 • Handed. • With rod connection. Rods Art. 1729 Length 648 or 958 mm. In unlocked position Latch bolts are operated from both sides by lever handle or key action on latch bolt. In locked position Dead bolt is locked. Latch bolts are operated from both sides by lever handle. Accessories None. Backset 65 mm Distance 72 mm Profile cylinder 9 mm follower Steel, zinc-plated front plate 24 x 288 mm rounded Steel, zinc-plated front plate 24 x 197 mm rounded Zinc-plated lock case Zinc-plated latch bolt Zinc-plated dead bolt Key action on latch bolt Packed per 25 pieces 1723/21 1729/21 THROW THROW Main lock Art. 1729/21 • • • • • • • • • • • • • • Art. 1729/21 and 1723/21 (2x) 23 1749 and 1742 Series. Fire-resistant mortise multi-point locks. 24 Main lock Art. 1749 Standards: CE marking and DIN 18250 T120 (Part 1) Upper lock Art. 1742/09 Standards: CE marking and DIN 18250 T120 (Part 1) Rod Art. 1742 Lower lock Art. 1742/09 Standards: CE marking and DIN 18250 T120 (Part 1) 1749 and 1742 Series. Fire-resistant mortise multi-point locks. Length 629, 689, 754 or 879 mm. In unlocked position Latch bolt is operated from both sides by lever handle/key action. In locked position Dead bolt and pivot dead bolts are locked. Latch bolt and lever handle are blocked. Note Please use Art. 1742 only in accordance with Art. 1749/09, 1749/37 and 1749/47. Accessories None. Backset 65 mm Distance 72 mm Profile cylinder 9 mm follower Steel, zinc-plated front plate 24 x 235 mm rounded Steel, zinc-plated lock case Steel, zinc-plated latch bolt Steel, zinc-plated dead bolt Key action on latch bolt Panic one-piece follower E Panic two-piece follower D Suitable for fixed rods Packed per 25 pieces Packed per 50 pieces • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • THROW Rods Art. 1742 1742/09 • Non-handed. • With adjustable rod application. 1749/47 Pivot dead bolts Art. 1742/09 1749/37 • Handed. • For European profile cylinder. • Key action on latch bolt. • Double throw dead bolt. • With rod movement up- and downwards. • Without strike plate. 1749/09 Main lock Art. 1749 THROW Specifications • • • • • • • • • Art. 1749 und 1742/09 (2x) 25 1901 and 1905 Series. Fire-resistant panic mortise locks for active leaf. Specifications • For European profile cylinder. • Key action on latch bolt. • Two-piece follower. • Without strike plate. Art. 1901 • Panic lock for active leaf. • Non-handed. Art. 1905/21 • Narrow style panic lock for active leaf. • Handed. Art. 1929/21 • Multi-point panic lock for active leaf. • Handed. In unlocked position Latch bolt is operated from both sides by lever handle/key action. In locked position No operation of latch bolt from outside. Operation latch bolt from inside handle. Art. 1901/17 is the same lock, however the forend is stainless steel. Backset 65 mm Backset 40 mm Distance 72 mm Profile cylinder 9 mm follower Steel, zinc-plated front plate 24 x 235 mm rounded Steel, zinc-plated front plate 24 x 350 mm rounded Stainless steel front plate 24 x 235 mm rounded Steel, zinc-plated front plate 24 x 288 mm rounded Steel, zinc-plated lock case for multi-point lock Steel, zinc-plated lock case Die-cast, zinc-plated latch bolt Key-action on latch bolt Non-handed Handed Packed per 25 pieces 26 1929/21 See pages 28, 29, 32 and 33. 1905/21 Accessories Art. 1901 Standards Art. 1901: CE marking, EN 1125 and EN 12209 Standards Art. 1905 and 1929: none 1901/21 Art. 1901 certified according to EN 1125. 1901/17 Note • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Art. 1901/21 1920, 1921 and 1925 Series. Fire-resistant panic mortise locks for passive leaf. Art. 1920/21 • Panic lock for passive leaf. • Handed. Art. 1921 • Art. 1921/17 and /21 panic lock for passive leaf. • Non-handed. Art. 1925 • Art. 1925/21 narrow style panic lock for passive leaf. • Handed. Function By operating the inside lever handle the upper and lower rods are retracted and the latch bolt in the active lock (Art. 1901/21 and 1905/21) pushed back, which opens both doors. In unlocked position The rods are held in unlocked position by the automatic relatching device. When closing the passive door, the rods are brought back in locked position automatically. In locked position Upper and lower rod can not be operated simultaneously. Do not use lever handle from outside on Art. 1920, 1921 and Art. 1925. Backset 65 mm Backset 40 mm Backset 95 mm 9 mm follower Steel, zinc-plated front plate 24 x 235 mm rounded Steel, zinc-plated front plate 24 x 350 mm rounded Stainless steel front plate 24 x 235 mm rounded Steel, zinc-plated lock case Non-handed Handed Packed per piece Packed per 25 pieces 1925/21 1921/21 1921/17 See pages 28, 29, 32 and 33. 1920/21 Accessories Art. 1921 Standards Art. 1921: EN 1125 Standards Art. 1920 and 1925: none • • • • • • • • • • • • • • • • • • • • • • • • • Art. 1921/21 27 3600 Series. Panic bar ‘Smart’. Horizontal panic bar The horizontal panic bar ‘Smart‘ is according to EN 1125 in combination with Art. 1901 and 1921 certified. It can be used with all panic locks of the Nemef 1700, 1900 and 9670/08 Series. The main feature of the panic bar is that the door can be opened in every situation by hand or by leaning against the door. Furthermore the bar is tested for operation on fire resistant doors with panic locks. Advantages Technical specification Spindles • Suitable for mortise locks: attractive design. • Non-handed: reducing stock. • Flexible program: complete range of accessories. • Easy to apply: minimal fixing time. •High quality in accordance with European standard. • Over 200.000 hittings for test in accordance with EN 1125:2008. • Opening power on non-loaded door: ≤80N. • Opening power on a 1000N loaded door: ≤220N. • Finger protection. • Bar projection 100 mm. •Neutral salt spraytest Grade 3: high resistance (96 hours EN 1670:1998). Mechanism Art. 3640/1 Standards: Art. 3640/1 and 3640/17: CE marking, EN 1125 classification 37611322A i.c.w. Art. 1901 and 1921 ADJUSTABLE •Art. 3621 9 mm square spindle, 125 mm. •Art. 3622 9 mm splitted square spindle, 55/55 mm, 65/65 mm. •Art. 3623 9 mm splitted square spindle, 38/55 mm. •Art. 3624 Splitted spindle 8/9 mm, 42/45 mm. •Art. 3625 Splitted spindle 9/8 mm, 77 mm. ADJUSTABLE Aluminium bar • Art. 3630/4 Aluminium rod. • Length: 900 or 1200 mm. Mechanism Art. 3640/1. Black painted steel mechanical housing with plastic cover. With steel core into the handle and plate. Application • Door width: 350 - 1300 mm. • Door thickness: 40 - 65 mm. • Distance: 72 mm or 92 mm. 92 mm is suitable for Narrow style panic lock 9670/08 Serie (see page 31). • Width: 34,5 mm. • With or without profile cylinder holes. Art. 3640/1 and 3640/17 Aluminium rod Art. 3630/4 28 3600 Series. Panic bar ‘Smart’. Stainless steel bar ‘Smart’ • Art. 3630/17, Stainless steel rod. • Length: 900 or 1200 mm. Mechanism Art. 3640/17. Stainless steel mechanical housing. With steel core into the handle and plate. Application • Door width: 350 - 1300 mm. • Door thickness: 40 - 65 mm. • Distance: 72 mm or 92 mm. 92 mm is suitable for Narrow style panic lock 9670/08 Serie (see page 31). • Width: 34,5 mm. • With or without profile cylinder holes. Rim-type Mechanism Art. 3640/17 (see Standards 3640/1) Stainless steel rod Art. 3630/17 Bar • Art. 3630/4, Aluminium rod. • Length: 900 or 1200 mm. Mechanism • Art. 3645/1, black painted connecting rods. • Art. 3650/1, black painted mechanical housing with plastic cover. With steel core into the handle and plate. Application • Door width: 350 - 1300 mm. • Non-handed. • Can only be used for double leaf doors in combination with the Smart version. Mechanism Art. 3650/1 Standards: none Connecting rods Art. 3645 29 9600 Series. Fire-resistant narrow-style lock. Specifications • To take profile cylinder. • Key action on latch bolt. • Backset 30, 35 and 40 mm. • Distance 92 mm. • Single throw dead bolt. • Latch reversible. • Follower 9 mm MPA registered. • Without strike plate. Accessories Strike plate P9600/17 stainless steel (page 41). 9600/08 Art. 9600/08 fire-resistant Standards: EN 12209 Backset 30, 35 and 40 mm Distance 92 mm To take profile cylinder Stainless steel front plate 24 x 245 mm square Steel, zinc-plated lock case Key action on latch bolt Single throw 9 mm follower MPA registered Packed per piece 30 • • • • • • • • • Art. 9600/08 9670 Series. Fire-resistant narrow-style panic lock. Specifications • To take profile cylinder. • Key action on latch bolt. • Backset 30, 35, 40 and 45 mm. • Distance 92 mm. • Single throw dead bolt. • One-piece follower, latch reversible. • Two-piece follower, handed. • Follower 8 or 9 mm. • Follower 9 mm MPA registered. • Without strike plate. Accessories Strike plate P9600/17 stainless steel (page 41). 9670/08 Art. 9670 Standards: CE marking and EN 179 Backset 30, 35, 40 and 45 mm Distance 92 mm To take profile cylinder Stainless steel front plate 24 x 245 mm square Steel, zinc-plated lock case Key action on latch bolt Single throw Panic one-piece follower, E Panic two-piece follower, D Packed per piece • • • • • • • • • • Art. 9670 31 Accessories 1900 and 3600 Series. Art. 1935 Automatic relatching device Art. 1936 Rod hasp bottom Art. 1937 Rod hasp top Art. 1938 Strike plate for Art. 1901 Art. 1939 Floor strike cup 32 Accessories 1900 and 3600 Series. Art. 1932 Zinc-plated rods with two closing bolts Length: 1200 mm Art. 1995 Flush bolt to be used for passive door and to combine with Art. 1932 Example use of Art. 1932 and 1935 33 2914 Series. Fire-resistant door handle. Art. 2914 • Back plate: Steel. • Cover plate: Plastic, black or aluminium look. • Handle: Plastic, black or aluminium look, fixed to plate. • Square spindle: 9 mm. • Door width: 40 - 63 mm. • Art. 2914/02: Lever/lever blind mat black. • Art. 2914/12: Lever/lever blind aluminium look. Art. 2914/02 Standards: DIN 18273 Art. 2914 34 2916 Series. Fire-resistant door handle. Art. 2916 • Back plate: Steel. • Cover plate: Plastic, black, grey, white, aluminium look or stainless steel. • Handle: Plastic, black, grey, white, aluminium look and stainless steel, fixed to plate. • Square spindle: 9 mm. • Door width: 40 - 63 mm. • Distance: 72 mm. • Art. 2916/02: Lever/lever black. • Art. 2916/05: Lever/lever grey. • Art. 2916/07: Lever/lever white. • Art. 2916/12: Lever/lever aluminium look. • Art. 2916/13: Lever/lever stainless steel. Also available in non fire-rated execution (without steel plate), Art. 2959/02 (page 38). Art. 2916/02 Standards: DIN 18273 Art. 2916 35 2919 Series lever/knob panic handle. Fire-resistant door handle. Knob-lever doorhandle Art. 2919 • Back plate: Steel. • Cover plate: Plastic, black, grey, aluminium look or stainless steel. • Handle: Plastic, fixed to plate, grey, aluminium look and stainless steel. • Square spindle: 9 mm. • Door width: 40 - 63 mm. • Distance: 72 mm. • Art. 2919/02: Lever/knob black. • Art. 2919/05: Lever/knob grey. • Art. 2919/12: Lever/knob aluminium look. • Art. 2919/13: Lever/knob stainless steel. Art. 2919/02 Standards: DIN 18273 and EN 179 Art. 2919 36 2924 Series lever/lever panic handle. Fire-resistant door handle. Lever handle panic furniture Art. 2924 • Back plate: Steel. • Cover plate: Plastic, black. • Handle: Plastic, black, fixed to plate. • Square spindle: 9 mm splitted. • Door width: 40 - 63 mm. • Distance: 72 mm. • Art. 2924/02: Lever/lever black. Art. 2924/02 Standards: DIN 18273 and EN 179 Art. 2924 37 2959 Series. Non fire-resistant door handle. Art. 2959/02 (non fire-resistant) • Plate: Black plastic. • Handle: Black plastic. • Square spindle: 8 mm. • Door width: 40 - 63 mm. • Distance: 72 mm. • Art. 2959/02: Lever/lever black. Art. 2959/02 Standards: none Art. 2959/02 38 1012 Series. Fire-resistant door hinges. Art. 1012/02 Fire-resistant door hinges. Zinc-plated finish. Set consisting of: • One spring hinge. • One non-spring hinge. • Fixing pin. • Fixing screw. Art. 1012/02 Standards: EN 1935 Art. 1012/02 39 Fire resistant plates. Art. 2930/02 black 72 mm Standards: none Art. 2934/02 black Standards: none 40 Art. 2931/02 black 72 mm Standards: none Art. 2935/02 black Standards: none Art. 2932/02 black Standards: none Art. 2936/02 black Standards: none Art. 2933/02 black Standards: none Strike plates*. Strike plates 1730 series For the 1730 and 1901 series the following strike plates can be used: Strike plate 1759 Series For the 1759 series the following strike plate can be used: Art. P 1739/12, steel zinc-plated, non-handed Art. P 1739/17, stainless steel, non-handed Art. P 1759/02, steel zinc-plated, non-handed Strike plates 1760 Series For the 1760 and 1740 series the following strike plates can be used: Strike plate 9600 Series For the 9600 Series Art. P 1769/66, steel zinc-plated, non-handed Art. P 1769/17, stainless steel, handed Art. P 9600/17 Stainless steel, non-handed * Standards: for strike plates are no standards. 41 Accessories. Art. BB7000 BB infill piece with 1 key Art. 1769/21 Reducing sleeve 8/9 mm 42 Art. BB1739 BB infill piece with 1 key Certificates* ISO 9001, EN 179 and EN 1125. If you require more information about the certificates or the combination of different locks with panic exit devices, please contact us. MATERIALPRÜFUNGSAMT NORDRHEIN-WESTFALEN EG–KONFORMITÄTSZERTIFIKAT 0432 – CPD – 0038 Gemäß der Richtlinie des Rates der Europäischen Gemeinschaften vom 21. Dezember 1988 zur Angleichung der Rechts– und Verwaltungsvorschriften der Mitgliedstaaten über Bauprodukte (Bauproduktenrichtlinie – CPD), geändert durch die Richtlinie 93/68/EWG des Rates der Europäischen Gemeinschaften vom 22. Juli 1993, wird hiermit bestätigt, dass das Bauprodukt Notausgangsverschlüsse NEMEF Notausgangstürverschlüsse mit Drücker für 1flügelige Türen gemäß der Zusammenstellung und Klassifikation in der Anlage 2, in Verkehr gebracht durch NEMEF BV Papegaaiweg 35 NL-7345 DK Wenum Wiesel und hergestellt in den Herstellwerken gemäß Anlage 1 durch den Hersteller einer werkseigenen Produktionskontrolle sowie zusätzlichen Prüfungen von im Werk entnommenen Proben nach festgelegtem Prüfplan unterzogen werden und dass die notifizierte Stelle Nr. - 0432 - MPA NRW – eine Erstprüfung der relevanten Eigenschaften des Produkts, eine Erstinspektion des Werkes und der werkseigenen Produktionskontrolle durchgeführt hat und eine laufende Überwachung, Beurteilung und Anerkennung der werkseigenen Produktionskontrolle durchführt. Dieses Zertifikat bestätigt, dass alle Vorschriften über die Bescheinigung der Konformität und die Leistungseigenschaften, beschrieben im Anhang ZA der Norm DIN EN 179: 2008-04 (EN 179: 2008 (D)) angewendet wurden und dass das Produkt alle darin vorgeschriebenen Anforderungen erfüllt. Dieses Zertifikat wurde erstmals am 15.04.2011 ausgestellt und gilt solange, wie die Festlegungen in der angeführten harmonisierten technischen Spezifikation oder die Herstellbedingungen im Werk oder die werkseigene Produktionskontrolle selbst nicht wesentlich verändert werden. Dortmund, 15.04.2011 Dip.-Ing. H. Jansen stellv.Leiter der Zertifizierungsstelle D I E SE S Z ER T I F I K AT U M F A SS T 1 S E IT E U N D 3 AN L AG EN . Marsbruchstraße 186 y 44287 Dortmund-Aplerbeck y Telefon (0231) 4502-480 y Telefax (0231) 4502 586 y Internet www.mpanrw.de * Certificates can be downloaded from our website www.nemef.com. 43 ASSA ABLOY is the global leader in door opening solutions, dedicated to satisfying end-user needs for security, safety and convenience. 9999990351 / JTP - 06/2012 ASSA ABLOY Nederland B.V. Business Unit Nemef P.O. Box 13 7300 AA Apeldoorn The Netherlands Tel. +31 55 3128400 Fax +31 55 3128406 export@nemef.nl www.nemef.com