MSDS for Iron Filings - Fine

advertisement

MATERIAL SAFETY DATA SHEET

Iron Filings Fine

SECTION 1 . Product and Company Idenfication

Product Name and Synonym: Iron Filings Fine

Product Code:

Material Uses:

Manufacturer:

I6553

Science Stuff

1104 Newport Ave

Health:

Flammability:

Reactivity:

2

1

2

Austin, TX 78753

(512) 837-6020

Entry Date : 6/7/2013

Print Date:

24 Hour Emergency Assistance :

6/7/2013

Chemtrec 800-424-9300

Canutec 613-996-6666

SECTION 2 HAZARD IDENTIFICATION

Hazard Rating:

Least Slight Moderate High Extreme

0 1 2 3 4

NA=Not Applicable NE=Not Established

May be harmful if swallowed. May cause irritation. Avoid breathing vapors, or dusts. Use with adequate ventilation. Avoid contact with eyes, skin, and clothes. Wash thoroughly after handling.

SECTION 3 MIXTURE COMPONENTS

SARA 313 Component

Iron Filings Fine

CAS Number

CAS# 7439-89-

6

Percent

Comp.

100%

Exposure

Limits

Dimension

W/W TXDS: orl-rat

LD•: 30 g/Kg

SECTION 4 FIRST AID MEASURES

May be harmful if swallowed. May cause irritation. Avoid breathing vapors, or dusts.

Use with adequate ventilation. Avoid contact with eyes, skin, and clothes. Wash thoroughly after handling.

FIRST AID: SKIN: Wash exposed area with soap and water. If irritation persists, seek medical attention.

EYES: Wash eyes with plenty of water for at least 15 minutes, lifting lids occasionally. Seek Medical Aid. INHALATION: Remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen

INGESTION: Give several glasses of water. Vomiting may occur, but it is not necessary to induce.

SECTION 5 FIRE FIGHTING MEASURES

Fire Extinguisher Type:

Any means suitable for extinguishing surrounding fire

None Known.

Fire / Explosion Hazards:

Fire Fighting Procedure: Wear self-contained breathing apparatus and protective clothing to prevent contact with skin and clothing.

SECTION 6 ACCIDENTAL RELEASE MEASURES

Iron Filings Fine

Dispose of in a manner consistent with federal, state and local regulations.

SECTION 7 HANDLING AND STORAGE

Store in a cool dry place. Do not get in eyes, on skin, on clothing. Wash thoroughly after handling

SECTION 8 EXPOSURE CONTROLS/PERSONAL PROTECTION

Respiratory Protection: None required

Ventilation

Local Exhaust

Mechanical

Protective Gloves: Gloves to prevent exposure

Eye Protection: Safety Glasses w/

Side Shields

Other Protective Equipment: Wear appropriate clothing to prevent skin exposure

SECTION 9 PHYSICAL AND CHEMICAL PROPERTIES

Melting Point:

Boiling Point:

Vapor Pressure:

1535° C

2750° C

N/A

Vapor Density:

Solubility in Water:

N/A

Insoluble

Appearance /Odors: Silver to gray metal in powder or granular form

Flash Point:

Specific Gravity:

N/A

7.87

Percent Volatile by Volume:

Evaporation Rate

Evaporation Standard

Auto Ignition Temp

Lower Flamm. Limit in Air

Upper Flamm. Limit in Air

SECTION 10 STABILITY AND REACTIVITY INFORMATION

Stability:

Conditions to Avoid:

Stable

Avoid contact with incompatible materials.

N/A

N/A

Not applicable

Not applicable

Not applicable

Materials to Avoid:

Hazardous Decomposition

Products:

Strong oxidizing agents, metals, acids, water, mineral acids

None

Hazardous polymerization:

Will Not Occur

Conditions to Avoid:

None known

SECTION 11 Toxicological Information

Oral rat LD50: 30 gm/kg; investigated as a tumorigen.

--------\Cancer Lists\------------------------------------------------------

---NTP Carcinogen---

Ingredient Known Anticipated IARC Category

Page 2 of 4

Iron Filings Fine

------------------------------------ ----- ----------- -------------

Iron Reduced (7439-89-6) No No None

SECTION 12 Ecological Information

Environmental Fate:

No information found.

Environmental Toxicity:

No information found.

SECTION 13 Disposal Considerations

Whatever cannot be saved for recovery or recycling should be managed in an appropriate and approved waste facility. Although not a listed RCRA hazardous waste, this material may exhibit one or more characteristics of a hazardous waste and require appropriate analysis to determine specific disposal requirements. Processing, use or contamination of this product may change the waste management options. State and local disposal regulations may differ from federal disposal regulations. Dispose of container and unused contents in accordance with federal, state and local requirements.

SECTION 14 Transport Information

DOT Classification: Not Regulated

DOT Regulations may change from time to time. Please consult the most recent D.O.T. regulations.

SECTION 15 Regulatory Information

--------\Chemical Inventory Status - Part 1\---------------------------------

Ingredient TSCA EC Japan Australia

----------------------------------------------- ---- --- ----- ---------

Iron Reduced (7439-89-6) Yes Yes No Yes

--------\Chemical Inventory Status - Part 2\---------------------------------

--Canada--

Ingredient Korea DSL NDSL Phil.

----------------------------------------------- ----- --- ---- -----

Iron Reduced (7439-89-6) Yes Yes No Yes

--------\Federal, State & International Regulations - Part 1\----------------

-SARA 302- ------SARA 313------

Ingredient RQ TPQ List Chemical Catg.

----------------------------------------- --- ----- ---- --------------

Iron Reduced (7439-89-6) No No No No

--------\Federal, State & International Regulations - Part 2\----------------

-RCRA- -TSCA-

Ingredient CERCLA 261.33 8(d)

----------------------------------------- ------ ------ ------

Iron Reduced (7439-89-6) No No No

Chemical Weapons Convention: No TSCA 12(b): No CDTA: No

SARA 311/312: Acute: Yes Chronic: Yes Fire: No Pressure: No

Reactivity: No (Pure / Solid)

Australian Hazchem Code: None allocated.

Poison Schedule: None allocated.

WHMIS:

This MSDS has been prepared according to the hazard criteria of the Controlled Products

Regulations (CPR) and the MSDS contains all of the information required by the CPR.

SECTION 16 Additional Information

Page 3 of 4

Iron Filings Fine

Flammability

Health Reactivity

Revisions

NFPA

0.1

Creation date LS

The information herein is believed to be accurate and is offered in good faith for the user's consideration and investigation. No warranty either expressed or implied is made for the completeness or accuracy of the information whether originating from the above mentioned company or not. Users of this material should satisfy themselves by independent investigation of current scientific and medical knowledge that the material can be used safely.

Page 4 of 4

Download