Iron Filings Fine
SECTION 1 . Product and Company Idenfication
Product Name and Synonym: Iron Filings Fine
Product Code:
Material Uses:
Manufacturer:
I6553
Science Stuff
1104 Newport Ave
Health:
Flammability:
Reactivity:
2
1
2
Austin, TX 78753
(512) 837-6020
Entry Date : 6/7/2013
Print Date:
24 Hour Emergency Assistance :
6/7/2013
Chemtrec 800-424-9300
Canutec 613-996-6666
SECTION 2 HAZARD IDENTIFICATION
Hazard Rating:
Least Slight Moderate High Extreme
0 1 2 3 4
NA=Not Applicable NE=Not Established
May be harmful if swallowed. May cause irritation. Avoid breathing vapors, or dusts. Use with adequate ventilation. Avoid contact with eyes, skin, and clothes. Wash thoroughly after handling.
SECTION 3 MIXTURE COMPONENTS
SARA 313 Component
Iron Filings Fine
CAS Number
CAS# 7439-89-
6
Percent
Comp.
100%
Exposure
Limits
Dimension
W/W TXDS: orl-rat
LD•: 30 g/Kg
SECTION 4 FIRST AID MEASURES
May be harmful if swallowed. May cause irritation. Avoid breathing vapors, or dusts.
Use with adequate ventilation. Avoid contact with eyes, skin, and clothes. Wash thoroughly after handling.
FIRST AID: SKIN: Wash exposed area with soap and water. If irritation persists, seek medical attention.
EYES: Wash eyes with plenty of water for at least 15 minutes, lifting lids occasionally. Seek Medical Aid. INHALATION: Remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen
INGESTION: Give several glasses of water. Vomiting may occur, but it is not necessary to induce.
SECTION 5 FIRE FIGHTING MEASURES
Fire Extinguisher Type:
Any means suitable for extinguishing surrounding fire
None Known.
Fire / Explosion Hazards:
Fire Fighting Procedure: Wear self-contained breathing apparatus and protective clothing to prevent contact with skin and clothing.
SECTION 6 ACCIDENTAL RELEASE MEASURES
Iron Filings Fine
Dispose of in a manner consistent with federal, state and local regulations.
SECTION 7 HANDLING AND STORAGE
Store in a cool dry place. Do not get in eyes, on skin, on clothing. Wash thoroughly after handling
SECTION 8 EXPOSURE CONTROLS/PERSONAL PROTECTION
Respiratory Protection: None required
Ventilation
Local Exhaust
Mechanical
Protective Gloves: Gloves to prevent exposure
Eye Protection: Safety Glasses w/
Side Shields
Other Protective Equipment: Wear appropriate clothing to prevent skin exposure
SECTION 9 PHYSICAL AND CHEMICAL PROPERTIES
Melting Point:
Boiling Point:
Vapor Pressure:
1535° C
2750° C
N/A
Vapor Density:
Solubility in Water:
N/A
Insoluble
Appearance /Odors: Silver to gray metal in powder or granular form
Flash Point:
Specific Gravity:
N/A
7.87
Percent Volatile by Volume:
Evaporation Rate
Evaporation Standard
Auto Ignition Temp
Lower Flamm. Limit in Air
Upper Flamm. Limit in Air
SECTION 10 STABILITY AND REACTIVITY INFORMATION
Stability:
Conditions to Avoid:
Stable
Avoid contact with incompatible materials.
N/A
N/A
Not applicable
Not applicable
Not applicable
Materials to Avoid:
Hazardous Decomposition
Products:
Strong oxidizing agents, metals, acids, water, mineral acids
None
Hazardous polymerization:
Will Not Occur
Conditions to Avoid:
None known
SECTION 11 Toxicological Information
Oral rat LD50: 30 gm/kg; investigated as a tumorigen.
--------\Cancer Lists\------------------------------------------------------
---NTP Carcinogen---
Ingredient Known Anticipated IARC Category
Page 2 of 4
Iron Filings Fine
------------------------------------ ----- ----------- -------------
Iron Reduced (7439-89-6) No No None
SECTION 12 Ecological Information
Environmental Fate:
No information found.
Environmental Toxicity:
No information found.
SECTION 13 Disposal Considerations
Whatever cannot be saved for recovery or recycling should be managed in an appropriate and approved waste facility. Although not a listed RCRA hazardous waste, this material may exhibit one or more characteristics of a hazardous waste and require appropriate analysis to determine specific disposal requirements. Processing, use or contamination of this product may change the waste management options. State and local disposal regulations may differ from federal disposal regulations. Dispose of container and unused contents in accordance with federal, state and local requirements.
SECTION 14 Transport Information
DOT Classification: Not Regulated
DOT Regulations may change from time to time. Please consult the most recent D.O.T. regulations.
SECTION 15 Regulatory Information
--------\Chemical Inventory Status - Part 1\---------------------------------
Ingredient TSCA EC Japan Australia
----------------------------------------------- ---- --- ----- ---------
Iron Reduced (7439-89-6) Yes Yes No Yes
--------\Chemical Inventory Status - Part 2\---------------------------------
--Canada--
Ingredient Korea DSL NDSL Phil.
----------------------------------------------- ----- --- ---- -----
Iron Reduced (7439-89-6) Yes Yes No Yes
--------\Federal, State & International Regulations - Part 1\----------------
-SARA 302- ------SARA 313------
Ingredient RQ TPQ List Chemical Catg.
----------------------------------------- --- ----- ---- --------------
Iron Reduced (7439-89-6) No No No No
--------\Federal, State & International Regulations - Part 2\----------------
-RCRA- -TSCA-
Ingredient CERCLA 261.33 8(d)
----------------------------------------- ------ ------ ------
Iron Reduced (7439-89-6) No No No
Chemical Weapons Convention: No TSCA 12(b): No CDTA: No
SARA 311/312: Acute: Yes Chronic: Yes Fire: No Pressure: No
Reactivity: No (Pure / Solid)
Australian Hazchem Code: None allocated.
Poison Schedule: None allocated.
WHMIS:
This MSDS has been prepared according to the hazard criteria of the Controlled Products
Regulations (CPR) and the MSDS contains all of the information required by the CPR.
SECTION 16 Additional Information
Page 3 of 4
Iron Filings Fine
Flammability
Health Reactivity
Revisions
NFPA
0.1
Creation date LS
The information herein is believed to be accurate and is offered in good faith for the user's consideration and investigation. No warranty either expressed or implied is made for the completeness or accuracy of the information whether originating from the above mentioned company or not. Users of this material should satisfy themselves by independent investigation of current scientific and medical knowledge that the material can be used safely.
Page 4 of 4