Worcester wiring guide Greenstar gas-fired boilers Contents Introduction Page 4 Greenstar Ri Regular Page 5 Greenstar CDi Regular Page 17 Greenstar CDi System Page 29 Greenstar CDi Combi Page 42 Greenstar FS CDi Regular Page 53 Greenstar HF CDi Combi Page 65 Greenstar Si Combi Page 71 Greenstar i Junior Combi Page 82 Greenstar i System Page 93 Notes Worcester wiring guide Greenstar gas-fired boilers Page 105 Page 3 Introduction NEW COMPLETE SYSTEM INSTALLATIONS If a new complete heating system installation is in a new build property or it is a first time installation in an existing property, then the heating system must conform to current building regulations Part L1a. All new heating systems in dwellings must have at least two heating zones. Each of these zones will be controlled by a thermostat and zone valve. An alternative would be individual electronically controlled TRVs. If the hot water is provided from a storage system then the DHW cylinder will require separate time and temperature control. All radiators must have TRVs fitted in all rooms except bathrooms and rooms with thermostats. The exception to this are single storey, open plan dwellings where the living area is more than 70% of the total useable floor area. Then this type of dwelling can be controlled as one zone. EXISTING INSTALLATIONS For boiler replacements on an existing system, it is not necessary to zone the upstairs and downstairs differently, compliance with the zone requirements can be achieved by a single room thermostat or programmable room thermostat. While the system is drained down, TRVs may be fitted to all rooms except the bathrooms and the room with the thermostat. Page 4 Worcester wiring guide Greenstar gas-fired boilers Greenstar Ri Regular 2 x 2 Port Valves (S-Plan) The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N = Neutral N E E = Earth Greenstar Ri Regular L N = Live L L N N = Neutral E E = Earth M Room T/Stat LP NP LR E reset L Cylinder T/Stat N 230V Mains Voltage Double Pole Fused Spur ~ N Heating Zone Valve max C 1 2 L N E L N E L N E 4 5 6 7 8 9 10 L N E External Pump HW ON CH ON M N ~ N E L Cylinder Zone Valve L Time Controller Worcester wiring guide Greenstar gas-fired boilers Page 5 Greenstar Ri Regular Mid Position Valve (Y-Plan) The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N = Neutral N E E = Earth Greenstar Ri Regular = Live L L N N = Neutral E E = Earth Mid Position Valve N L N Room T/Stat LP NP LR reset Green/Yellow Blue White Grey Orange Cylinder T/Stat N 230V Mains Voltage Double Pole Fused Spur E C max 1 2 L N E L N E L N E 4 5 6 7 8 9 10 HW OFF CH ON External Pump HW ON L N E N L Time Controller Page 6 Worcester wiring guide Greenstar gas-fired boilers Greenstar Ri Regular 3 x 2 Port Valves (S-Plan Plus) The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N = Neutral N E E = Earth Greenstar Ri Regular L N = Live L L N N = Neutral E E = Earth M Room T/Stat Zone 1 LP NP LR E reset L Cylinder T/Stat N 230V Mains Voltage Double Pole Fused Spur ~ N Heating Zone 1 Valve max C 1 2 L N E L N E L N E 4 5 6 7 8 9 10 L N E CH Zone 1 ON HW ON M CH Zone 2 ON External Pump ~ N E L Cylinder Zone Valve N M ~ N L E Time Controller 3 Channel N L Heating Zone 2 Valve Room T/Stat Zone 2 Worcester wiring guide Greenstar gas-fired boilers Page 7 Greenstar Ri Regular 2 x Radiator Heating Zones The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N = Neutral N E E = Earth Greenstar Ri Regular L N = Live L L N N = Neutral E E = Earth M Room T/Stat Zone 1 LP NP LR reset E Room T/Stat Zone 2 N 230V Mains Voltage Double Pole Fused Spur ~ N Heating Zone 1 Valve N max L L N E L N E L N E 4 5 6 7 8 9 10 CH Zone 2 ON External Pump CH Zone 1 ON L N E N M ~ N E L Heating Zone 2 Valve L Time Controller Page 8 Worcester wiring guide Greenstar gas-fired boilers Greenstar Ri Regular 2 x 2 Port Valves & Underfloor Heating The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N = Neutral N E E = Earth Greenstar Ri Regular L N = Live L L N N = Neutral E E = Earth M Room T/Stat Zone 1 LP NP LR E reset L Cylinder T/Stat N 230V Mains Voltage Double Pole Fused Spur ~ N Heating Zone 1 Valve max C 2 1 L N E E L N E L N E External Pump 4 5 6 7 8 9 10 M ~ N HW ON N CH Zone 1 ON L E L Cylinder Zone Valve N L N E L N E L Time Controler Twin Channel Demand Underfloor Controls Wiring Centre Worcester wiring guide Greenstar gas-fired boilers Page 9 Greenstar Ri Regular Zoned Radiator & Underfloor Heating The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N = Neutral N E = Earth E Greenstar Ri Regular L N LP NP LR = Live L L N N = Neutral E E = Earth M Room T/Stat Radiators Zone ~ N E L N 230V Mains Voltage Double Pole Fused Spur reset Radiators Zone Valve max L N E L N E L N E L N E 4 5 6 External Pump N L Time Controller Single Channel Page 10 7 8 9 10 L N E L N E Demand Underfloor Controls Wiring Centre Worcester wiring guide Greenstar gas-fired boilers Greenstar Ri Regular Single Hot Water Zone (Vented Cylinder) The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N = Neutral N E E = Earth Greenstar Ri Regular = Live L L N N = Neutral E E = Earth Cylinder T/Stat C L N LP NP LR 2 1 230V Mains Voltage Double Pole Fused Spur reset max L N E L N E L N E 4 5 6 7 8 9 10 L N E External Pump N L Time Controller Single Channel Worcester wiring guide Greenstar gas-fired boilers Page 11 Greenstar Ri Regular Single Heating Zone The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N = Neutral N E E = Earth Greenstar Ri Regular = Live L L N N = Neutral E E = Earth Room T/Stat N L N 230V Mains Voltage Double Pole Fused Spur LP NP LR reset max L N E L N E L N E 4 5 6 7 8 9 10 L N E External Pump N L Time Controller Single Channel Page 12 Worcester wiring guide Greenstar gas-fired boilers Greenstar Ri Regular Grundfoss Pump Plan The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N = Neutral N E E = Earth IMPORTANT NOTE The pump over-run of the pump plan module, causes the hot water pump to run regardless of the hot water cylinder demand, to dissipate boiler heat. Worcester will only recommend the Grundfoss pump plan system on a vented cylinder. Greenstar Ri Regular 230V Mains Voltage Double Pole Fused Spur L N LP NP LR Warning! 240V - Isolate electrical supply before removing wiring centre cover. reset L N E max 2.5A Fuse - RS Components stock no 415-604 BOILER FUSE 2.5A N L N L S/L 1 Frost T/Stat FROST T/STAT (if required) (N/U) 2 C (N/U) NO Demand N L NO N d an em C D 2 De m an d (N/U) 1 Cylinder T/Stat CYLINDER T/STAT C (N/U) L L N ROOM T/STAT Room T/Stat P/L N N NO 1 HW PUMP HW Pump N L CH PUMP CHPump N CH on HW on N L CH on PROGRAMMER HW on 4 (N/U) (N/U) CH/HW Programmer 3 Earth terminal for: Controls, Boiler, Pumps Electrical Mains Supply (N/U) 2 L N/U = Not Used UPP 15-50 PUMP PLAN - WIRING CENTRE CONNECTIONS Worcester wiring guide Greenstar gas-fired boilers Page 13 Greenstar Ri Regular Smartfit Control Pack The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N = Neutral N E E = Earth Greenstar Ri Regular L 230V Mains Voltage Double Pole Fused Spur N SMARTFIT ROOM UNIT LP NP LR reset Smartfit Layout: Example shown S Plan configuration max MAINS BOILER L N E PUMP L N E N SMARTFIT FROST PROTECTION ROOM UNIT A L L SL POLARITY FREE Y PLAN S PLAN PL N N L HW VALVE (S) CH VALVE (S) 3 PORT VALVE (Y) ACCESSORY PORT CYLINDER SENSOR External Pump HW VALVE (S) CH VALVE (S) Page 14 CYLINDER T/STAT Worcester wiring guide Greenstar gas-fired boilers Greenstar Ri Regular Cascaded boilers with low loss header The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N = Neutral N E = Earth E NOTE A pump must be wired to each boiler for pump over-run to dissipate heat from within the boiler. The connections are Live of pump to LP and Neutral of pump to NP and the Earth of the pump to the Earth point of each boiler. HEADER LIMIT THERMOSTAT This cuts the Demand to the boilers in the event of excessive temperature within the Header due to lack of circulation. Ideally this should be set to 90º C. Wiring from Zone/s Controls IMPORTANT NOTE: The Relay should be mounted within a suitable electrically safe housing. Junction Box/Wiring Centre L N Switched Live/ Demand E NO NC NC C Header Limit Thermostat C N O N C L 230V Mains Voltage Double Pole Fused Spur N C Greenstar Ri Regular LP NP LR reset C Coil Coil Live Neutral Example relay shown is a Double Pole Mains Voltage Relay. This isolates the Boilers electrically in case of a fault condition. 230V AC Double Pole Relay C Greenstar Ri Regular NO L max N LP NP LR reset max L N E L N E Shunt Pump Worcester wiring guide Greenstar gas-fired boilers L N E Shunt Pump Page 15 Greenstar Ri Regular Frost Protection The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N = Neutral N E E = Earth NOTE A frost thermostat is normally used to protect locations which have no heat source e.g. a garage. It is recommended that a pipe thermostat is also used (wired in series with the frost thermostat) to avoid long periods of heat demand if the air temperature does not satisfy the frost thermostat. Frost T/Stat Pipe T/Stat Greenstar Ri Regular L N reset L N = Neutral E E = Earth Room T/Stat LP NP LR Cylinder T/Stat N 230V Mains Voltage Double Pole Fused Spur = Live L N Heating Zone Valve max C 1 2 L N E E L N E 4 L N E 5 6 7 8 9 10 HW ON N CH ON L N External Pump L Time Controller Page 16 Worcester wiring guide Greenstar gas-fired boilers Greenstar CDi Regular 2 x 2 Port Valves (S-Plan) The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth = Live L L N N = Neutral E Greenstar CDi Regular E = Earth Room T/Stat M N E LZ NZ L ~ N L Cylinder T/Stat Heating Zone Valve C N NS LS LR 1 230V Mains Voltage Double Pole Fused Spur L N E L N E L N E 4 5 6 7 2 8 9 10 HW ON CH ON M L N E ~ N E L E N External Pump Cylinder Zone Valve L Time Controller Worcester wiring guide Greenstar gas-fired boilers Page 17 Greenstar CDi Regular Mid Position Valve (Y-plan) The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth = Live L L N N = Neutral E E = Earth Mid Position Valve Room T/Stat Greenstar CDi Regular N N E Green/Yellow Blue White Grey Orange Cylinder T/Stat LZ NZ C L N NS LS LR 1 230V Mains Voltage Double Pole Fused Spur L N E L N E 4 5 6 7 2 8 9 10 External Pump HW OFF E HW ON L N E CH ON L N E N L Time Controller Page 18 Worcester wiring guide Greenstar gas-fired boilers Greenstar CDi Regular 3 x 2 Port Valves (S-Plan Plus) The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth Greenstar CDi Regular = Live L L N N = Neutral E E = Earth Room T/Stat Zone 1 M LZ NZ L ~ N N E Cylinder T/Stat Heating Zone 1 Valve C N NS LS LR 1 L 2 230V Mains Voltage Double Pole Fused Spur L N E L N E 4 5 6 7 L N E External Pump CH Zone 1 ON E HW ON 8 9 10 M CH Zone 2 ON L N E ~ N E L Cylinder Zone Valve N M ~ N L E Time Controller 3 Channel N L Heating Zone 2 Valve Room T/Stat Zone 2 Worcester wiring guide Greenstar gas-fired boilers Page 19 Greenstar CDi Regular 2 x Radiator Heating Zones The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth Greenstar CDi Regular = Live L L N N = Neutral E E = Earth Room T/Stat Zone 1 M N LZ NZ E Room T/Stat Zone 2 N NS LS LR L N E N E L N E 4 5 6 CH Zone 2 ON L N E L CH Zone 1 ON 230V Mains Voltage Double Pole Fused Spur 7 8 9 10 M ~ N E L E N External Pump L Heating Zone 1 Valve N L ~ N Heating Zone 2 Valve L Time Controller Page 20 Worcester wiring guide Greenstar gas-fired boilers Greenstar CDi Regular 2 x 2 Port Valves & Underfloor Heating The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth Greenstar CDi Regular L N = Neutral E E = Earth Room T/Stat Zone 1 M ~ N N LZ NZ L = Live L N E Cylinder T/Stat L Heating Zone 1 Valve C N NS LS LR 2 1 N E L N E L N E L N E 4 5 6 8 9 10 M ~ N E E L Cylinder Zone Valve N External Pump 7 HW ON L CH Zone 1 ON 230V Mains Voltage Double Pole Fused Spur L N E L N E L Time Controller Twin Channel Demand Underfloor Controls Wiring Centre Worcester wiring guide Greenstar gas-fired boilers Page 21 Greenstar CDi Regular Zoned Radiator & Underfloor Heating The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E Greenstar CDi Regular = Earth = Live L L N N = Neutral E E = Earth Room T/stat Radiators Zone M N E LZ NZ L ~ N L Radiators Zone Valve N NS LS LR 230V Mains Voltage Double Pole Fused Spur L N E L N E 4 5 6 7 8 9 10 L N E L N E External Pump Page 22 E N L Time Controller Single Channel L N E L N E Demand Underfloor Controls Wiring Centre Worcester wiring guide Greenstar gas-fired boilers Greenstar CDi Regular Single Hot Water Zone (Vented Cylinder) The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N = Neutral N E E = Earth = Live L L N N = Neutral E E = Earth Cylinder T/Stat Greenstar CDi Regular C L 2 1 LZ NZ N NS LS LR 230V Mains Voltage Double Pole Fused Spur L N E L N E 4 5 6 7 8 9 10 L N E L N E N E L External Pump Worcester wiring guide Greenstar gas-fired boilers Time Controller Single Channel Page 23 Greenstar CDi Regular Single Heating Zone The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N = Neutral N E E = Earth = Live L L N N = Neutral E E = Earth Room T/Stat Greenstar CDi Regular N LZ NZ L N NS LS LR 230V Mains Voltage Double Pole Fused Spur L N E L N E 4 5 6 7 8 9 10 L N E L N E N E L External Pump Page 24 Time Controller Single Channel Worcester wiring guide Greenstar gas-fired boilers Greenstar CDi Regular Grundfoss Pump Plan The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N = Neutral N E = Earth E IMPORTANT NOTE The pump over-run of the pump plan controls, causes the hot water pump to run regardless of the hot water cylinder demand, to dissipate boiler heat. Worcester would only recommend the Grundfoss pump plan system on a vented cylinder. Greenstar CDi Regular LZ NZ N NS LS LR L 230V Mains Voltage Double Pole Fused Spur Warning! 240V - Isolate electrical supply before removing wiring centre cover. L N E 2.5A Fuse - RS Components stock no 415-604 BOILER FUSE 2.5A N L N L S/L 1 Frost T/Stat FROST T/STAT (if required) (N/U) 2 C (N/U) NO Demand D em an d 2 N NO N C De m an d (N/U) 1 Cylinder T/Stat CYLINDER T/STAT C (N/U) L L N L ROOM T/STAT Room T/Stat P/L N N NO 1 HW PUMP HW Pump N L CH PUMP CHPump N CH on HW on N L CH on PROGRAMMER HW on 4 (N/U) (N/U) CH/HW Programmer 3 Earth terminal for: Controls, Boiler, Pumps Electrical Mains Supply (N/U) 2 L N/U = Not Used UPP 15-50 PUMP PLAN - WIRING CENTRE CONNECTIONS Worcester wiring guide Greenstar gas-fired boilers Page 25 Greenstar CDi Regular Smartfit Control Pack The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N = Neutral N E E = Earth Greenstar CDi Regular LZ NZ L N NS LS LR SMARTFIT ROOM UNIT 230V Mains Voltage Double Pole Fused Spur Smartfit Layout: Example shown S Plan configuration MAINS L N E BOILER PUMP L N E N SMARTFIT FROST PROTECTION ROOM UNIT A L L SL Y PLAN S PLAN PL N N L HW VALVE (S) CH VALVE (S) 3 PORT VALVE (Y) POLARITY FREE ACCESSORY PORT CYLINDER SENSOR External Pump HW VALVE (S) CH VALVE (S) Page 26 CYLINDER T/STAT Worcester wiring guide Greenstar gas-fired boilers Greenstar CDi Regular Cascaded boilers with low loss header The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth NOTE A pump must be wired to each boiler for pump over-run function to dissipate heat from within the boiler. The connections are pump live to Lz, pump neutral to Nz and pump earth to the Earth point of each boiler. HEADER LIMIT THERMOSTAT This cuts the Demand to the boilers in the event of excessive temperature within the Header due to lack of circulation. Ideally this should be set to 90ºC. Wiring from Zone/s Controls IMPORTANT NOTE: The relay should be mounted within a suitable electrically safe housing. Junction Box/Wiring Centre L N Switched Live/ Demand E NO NC NC C Header Limit Thermostat C N O N C 230V AC Double Pole Relay C C Coil Coil Live Neutral Example relay shown is a double pole mains voltage relay. This isolates the boilers electrically in case of a fault condition. C Greenstar CDi Regular Greenstar CDi Regular LZ NZ L NO N NS LS LR LZ NZ L N NS LS LR 230V Mains Voltage Double Pole Fused Spur L N E L N E Shunt Pump Worcester wiring guide Greenstar gas-fired boilers L N E Shunt Pump Page 27 Greenstar CDi Regular Frost Protection The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth The boiler has inbuilt frost protection. When the primary temperature drops below 8°C the pump is switched on. When then temperature rises above 9°C the pump switches off after a 3 minute pump overrun. If the primary temperature drops below 5°C, a central heating demand is activated until the primary temperature rises above 12 °C. The demand switches off followed by the pump after a 3 minute overrun. The boiler has the facility to connect an external frost protection device to protect in “at risk areas” (terminal block ST6, contacts FS and FR). This is used if the boiler is not located in the area needing protection i.e. boiler in kitchen but pipe work in the garage that needs frost protection. If external frost thermostat is calling, i.e. temperature within frost thermostat below the set point, but the primary temperature of the boiler is above 5°C, the pump will run until the temperature within the frost thermostat rises above the set point. If external frost thermostat is calling and the primary temperature is below 5°C, a central heating demand is activated until primary temperature is above 12 °C. If the frost thermostat is still calling the pump will run until the temperature within the frost thermostat location rises above the set point. Frost T/Stat Greenstar CDi Regular FR FS NP LP LZ NZ L N NS LS LR 230V Mains Voltage Double Pole Fused Spur Earth to Wiring Centre Neutral Feed to Wiring Centre Live Feed to Wiring Centre Switch Live from Wiring Centre L N E L N E External Pump Page 28 Worcester wiring guide Greenstar gas-fired boilers Greenstar CDi System 2 x 2 Port Valves (S-Plan) The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth L N N = Neutral E Room T/Stat Greenstar CDi System = Live L E = Earth M ~ N N E L Cylinder T/Stat L Heating Zone Valve C N NS LS LR 1 2 230V Mains Voltage Double Pole Fused Spur L N E L N E L N E 4 5 6 7 8 9 10 HW ON CH ON M N ~ N E L Cylinder Zone Valve L Time Controller Worcester wiring guide Greenstar gas-fired boilers Page 29 Greenstar CDi System Mid Position Valve (Y-Plan) The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth Greenstar CDi System = Live L L N N = Neutral E E Mid Position Valve = Earth Room T/Stat N N E Green/Yellow Blue White Grey Orange Cylinder T/Stat C L 230V Mains Voltage Double Pole Fused Spur N NS LS LR 1 L N E L N E 4 5 6 7 2 8 9 10 HW OFF HW ON CH ON L N E N L Time Controller Page 30 Worcester wiring guide Greenstar gas-fired boilers Greenstar CDi System 3 x 2 Port Valves (S-Plan Plus) The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth Greenstar CDi System = Live L L N N = Neutral E E = Earth Room T/Stat Zone 1 M ~ N N E L Cylinder T/Stat L Heating Zone 1 Valve C N NS LS LR 1 L N E L N E L N E 4 CH Zone 1 ON HW ON 5 6 7 8 9 10 M CH Zone 2 ON 230V Mains Voltage Double Pole Fused Spur 2 ~ N E L Cylinder Zone Valve N M N L E Time Controller 3 Channel N ~ L Heating Zone 2 Valve Room T/Stat Zone 2 Worcester wiring guide Greenstar gas-fired boilers Page 31 Greenstar CDi System 2 x Heating Zones The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth Greenstar CDi System = Live L L N N = Neutral E E = Earth Room T/Stat Zone 1 M N E Room T/Stat Zone 2 230V Mains Voltage Double Pole Fused Spur N NS LS LR L N E L N E 4 5 6 L Heating Zone 1 Valve N L ~ N 7 8 9 10 CH Zone 2 ON CH Zone 1 ON L N E N M ~ N E L Heating Zone 2 Valve L Time Controller Page 32 Worcester wiring guide Greenstar gas-fired boilers Greenstar CDi System 2 x 2 Port Valves & Underfloor Heating The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth Greenstar CDi System = Live L L N N = Neutral E E = Earth Room T/Stat Zone 1 M E N L Heating Zone 1 Valve C N NS LS LR 2 N E L N E 4 5 6 7 8 9 10 M ~ N HW ON L CH Zone 1 ON L N E L Cylinder T/Stat 1 230V Mains Voltage Double Pole Fused Spur ~ N E L Cylinder Zone Valve N L N E L N E L Time Controller Twin Channel Demand Underfloor Controls Wiring Centre Worcester wiring guide Greenstar gas-fired boilers Page 33 Greenstar CDi System Zoned Radiator & Underfloor The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral Greenstar CDi System E E = Earth = Live L L N N = Neutral E E = Earth Room T/Stat Radiators Zone M E N L 230V Mains Voltage Double Pole Fused Spur L N E L Radiators Zone Valve N NS LS LR L N E L N E 4 5 6 N L Time Controller Single Channel Page 34 ~ N 7 8 9 10 L N E L N E Demand Underfloor Controls Wiring Centre Worcester wiring guide Greenstar gas-fired boilers Greenstar CDi System Single Hot Water Zone (Vented Cylinder) The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N = Neutral N E E = Earth = Live L L N N = Neutral E E = Earth Cylinder T/Stat Greenstar CDi System C 2 1 L N NS LS LR 230V Mains Voltage Double Pole Fused Spur L N E L N E L N E 4 5 6 7 8 9 10 N L Time Controller Single Channel Worcester wiring guide Greenstar gas-fired boilers Page 35 Greenstar CDi System Single Heating Zone The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N = Neutral N E E = Earth = Live L L N N = Neutral E E = Earth Room T/Stat Greenstar CDi System N L N NS LS LR 230V Mains Voltage Double Pole Fused Spur L N E L N E L N E 4 5 6 7 8 9 10 N L Time Controller Single Channel Page 36 Worcester wiring guide Greenstar gas-fired boilers Greenstar CDi System Smartfit Control Pack The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth Greenstar CDi System L N NS LS LR SMARTFIT ROOM UNIT 230V Mains Voltage Double Pole Fused Spur MAINS L N E Smartfit Layout: Example shown S Plan configuration N SMARTFIT FROST PROTECTION ROOM UNIT A L BOILER L SL Y PLAN S PLAN PL N PUMP N L HW VALVE (S) CH VALVE (S) 3 PORT VALVE (Y) POLARITY FREE ACCESSORY PORT CYLINDER SENSOR HW VALVE (S) CH VALVE (S) Worcester wiring guide Greenstar gas-fired boilers CYLINDER T/STAT Page 37 Greenstar CDi System Internal Diverter Valve, Worcester RF Controls & Unvented Cylinder The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E = Earth E There is a unclarity within the Industry that in order to protect an Unvented Hot Water Cylinder from potentially dangerous high temperatures from the boiler circuit, a 2-port motorised valve must be installed. This is not the case, although it is the most common interpretation and approach. FURTHER DETAILS Building Regulation Approved Document G3, paragraph 3.6 states '…the non-self-resetting thermal cut out should be wired to a motorised valve or some other suitable device to shut off the flow to the primary heater…'. The latter part of this sentence can be interpreted to mean as long as we, as responsible Manufacturer's, are confident our method provides an equal amount of protection to the common approach, we may instruct installers of our equipment to follow a different approach. A summary is provided below. G The installer will use the cylinder sensor supplied with the Integral Diverter Valve kit to control the hot water temperature. G The installer, therefore, will NOT need to use the hot water control thermostat of the cylinder's dual thermostat. G The installer may have to alter the wiring of the dual thermostat (depending on cylinder and thermostat manufacturer) to only use the high limit thermal cut-out of the dual thermostat. G The high limit thermal cut out of the dual thermostat MUST be wired to interrupt the permanent live to the Greenstar CDi System Boiler. G The 2-port valve supplied with the unvented cylinder will NOT be used. If it is already physically installed in the pipe work is should be removed and electrically disconnected from the wiring centre. Below you will find an electrical diagram for this arrangement. DUAL THERMOSTAT 230V MAINS SUPPLY SAFETY LIMIT THERMOSTAT CYLINDER THERMOSTAT Connector Block Green\Yellow (made safe) NOT REQUIRED USE CYLINDER SENSOR SUPPLIED IMPORTANT NOTE: UNDER NO CIRCUMSTANCES SHOULD THE FEED TO THE LIMIT STAT BE TAKEN THROUGH THE CONTROL STAT. Brown Blue Brown N E L ST8 9 8 L FR FS NP LP ST10 ST6 Pump Harness Fan Harness FR FS NP LP L N NS LS LR 9 ST19 B B 4 2 1 A F B B 4 2 1 A F CYLINDER TEMPERATURE SENSOR (SUPPLIED IN 8 7 S11 2.5 A 230 V AC NOTE: Leave link 7 NOTE: Leave link LR LS NS N DIVERTER KIT) Main Harness DIVERTER VALVE MOTOR PLUG S12 0.5 A S13 1.6 A Pump Control Code Plug Page 38 Worcester wiring guide Greenstar gas-fired boilers Greenstar CDi System Internal Diverter Valve, Worcester FX Controls & Unvented Cylinder The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E = Earth E There is a unclarity within the Industry that in order to protect an Unvented Hot Water Cylinder from potentially dangerous high temperatures from the boiler circuit, a 2-port motorised valve must be installed. This is not the case, although it is the most common interpretation and approach. FURTHER DETAILS Building Regulation Approved Document G3, paragraph 3.6 states '…the non-self-resetting thermal cut out should be wired to a motorised valve or some other suitable device to shut off the flow to the primary heater…'. The latter part of this sentence can be interpreted to mean as long as we, as responsible Manufacturer's, are confident our method provides an equal amount of protection to the common approach, we may instruct installers of our equipment to follow a different approach. A summary is provided below. G The installer will use the cylinder sensor supplied with the Integral Diverter Valve kit to control the hot water temperature. G The installer, therefore, will NOT need to use the hot water control thermostat of the cylinder's dual thermostat. G The installer may have to alter the wiring of the dual thermostat (depending on cylinder and thermostat manufacturer) to only use the high limit thermal cut-out of the dual thermostat. G The high limit thermal cut out of the dual thermostat MUST be wired to interrupt the permanent live to the Greenstar CDi System Boiler. G The 2-port valve supplied with the unvented cylinder will NOT be used. If it is already physically installed in the pipe work is should be removed and electrically disconnected from the wiring centre. Below you will find an electrical diagram for this arrangement. DUAL THERMOSTAT 230V MAINS SUPPLY SAFETY LIMIT THERMOSTAT CYLINDER THERMOSTAT Connector Block Green\Yellow (made safe) NOT REQUIRED USE CYLINDER SENSOR SUPPLIED IMPORTANT NOTE: UNDER NO CIRCUMSTANCES SHOULD THE FEED TO THE LIMIT STAT BE TAKEN THROUGH THE CONTROL STAT. Brown Blue Brown N E L ST8 9 8 L FR FS NP LP ST10 ST6 Pump Harness 9 Fan Harness FR FS NP LP ST19 B FW 100 B CONTROLLER B B 4 2 1 A F B B 4 2 1 A F A OUTSIDE F SENSOR CYLINDER TEMPERATURE SENSOR (SUPPLIED IN 8 7 L N NS LS LR S11 2.5 A 230 V AC NOTE: Leave link 7 NOTE: Leave link LR LS NS N DIVERTER KIT) Main Harness DIVERTER VALVE MOTOR PLUG S12 0.5 A S13 1.6 A Pump Control Code Plug Worcester wiring guide Greenstar gas-fired boilers Page 39 Greenstar CDi System Cascaded boilers with low loss header The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth HEADER LIMIT THERMOSTAT This cuts the Demand to the boilers in the event of excessive temperature within the Header due to lack of circulation. Ideally this should be set to 90º C. Wiring from Zone/s Controls IMPORTANT NOTE: The Relay should be mounted within a suitable electrically safe housing. Junction Box/Wiring Centre L N Switched Live/ Demand E N C 230V AC Double Pole Relay C N NS LS LR NC NO C Coil Coil Live Neutral Example relay shown is a Double Pole Mains Voltage Relay. This isolates the Boilers electrically in case of a fault condition. C Greenstar CDi System L NC C Header Limit Thermostat C N O NO Greenstar CDi System L N NS LS LR 230V Mains Voltage Double Pole Fused Spur L N E Page 40 Worcester wiring guide Greenstar gas-fired boilers Greenstar CDi System Frost Protection The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth The boiler has inbuilt frost protection. When the primary temperature drops below 8°C the pump is switched on. When then temperature rises above 9°C the pump switches off after a 3 minute pump overrun. If the primary temperature drops below 5°C, a central heating demand is activated until the primary temperature rises above 12 °C. The demand switches off followed by the pump after a 3 minute overrun. The boiler has the facility to connect an external frost protection device to protect in “at risk areas” (terminal block ST6, contacts FS and FR). This is used if the boiler is not located in the area needing protection i.e. boiler in kitchen but pipe work in the garage that needs frost protection. If external frost thermostat is calling, i.e. temperature within frost thermostat below the set point, but the primary temperature of the boiler is above 5°C, the pump will run until the temperature within the frost thermostat rises above the set point. If external frost thermostat is calling and the primary temperature is below 5°C, a central heating demand is activated until primary temperature is above 12 °C. If the frost thermostat is still calling the pump will run until the temperature within the frost thermostat location rises above the set point. Frost T/Stat Greenstar CDi System FR FS NP LP L N NS LS LR 230V Mains Voltage Double Pole Fused Spur L N E Worcester wiring guide Greenstar gas-fired boilers Earth to Wiring Centre Neutral Feed to Wiring Centre Live Feed to Wiring Centre Switch Live from Wiring Centre Page 41 Greenstar CDi Combi 2 x 2 Port Valves (S-Plan) The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth = Live L L N N = Neutral E E = Earth Greenstar CDi Combi M Room T/Stat E L N E Heating Zone Valve C N NS LS LR 1 230V Mains Voltage Double Pole Fused Spur L Cylinder T/Stat N L ~ N L N E L N E 4 5 6 7 2 8 9 10 HW ON CH ON M N ~ N E L Cylinder Zone Valve L Time Controller Page 42 Worcester wiring guide Greenstar gas-fired boilers Greenstar CDi Combi Mid Position Valve (Y-Plan) The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth Greenstar CDi Combi = Live L L N N = Neutral E E = Earth Mid Position Valve N Room T/Stat E Green/Yellow Blue White Grey Orange Cylinder T/Stat N C L N E L N E 4 CH ON L N E 1 5 6 7 2 8 9 10 HW OFF 230V Mains Voltage Double Pole Fused Spur N NS LS LR HW ON L N L Time Controller Worcester wiring guide Greenstar gas-fired boilers Page 43 Greenstar CDi combi 3 x 2 Port Valves (S-Plan Plus) The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth Greenstar CDi Combi L N N = Neutral E E = Earth M Room T/Stat Zone 1 ~ N E Heating Zone 1 Valve C N NS LS LR 1 L N E L N E L N E 4 5 6 7 2 8 CH Zone 1 ON HW ON 9 10 M CH Zone 2 ON 230V Mains Voltage Double Pole Fused Spur L Cylinder T/Stat N L = Live L ~ N E L Cylinder Zone Valve N M ~ N L E Time Controller 3 Channel N L Heating Zone 2 Valve Room T/Stat Zone 2 Page 44 Worcester wiring guide Greenstar gas-fired boilers Greenstar CDi combi 2 x Heating Zones The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth = Live L L N N = Neutral E E = Earth Greenstar CDi Combi M Room T/Stat Zone 1 E Room T/Stat Zone 2 N L N E L N E 4 5 6 CH Zone 2 ON L N E N NS LS LR CH Zone 1 ON 230V Mains Voltage Double Pole Fused Spur N L Heating Zone 1 Valve N L ~ N 7 8 9 10 M ~ N E L Heating Zone 2 Valve L Time Controller Worcester wiring guide Greenstar gas-fired boilers Page 45 Greenstar CDi Combi 2 x 2 Port Valves & Underfloor Heating The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth Greenstar CDi Combi = Live L L N N = Neutral E E = Earth Room T/Stat Zone 1 M ~ N N E L Cylinder T/Stat L 2 1 N E L N E 4 5 6 7 8 9 10 M ~ N HW ON L N E L CH Zone 1 ON 230V Mains Voltage Double Pole Fused Spur Heating Zone 1 Valve C N NS LS LR E L Cylinder Zone Valve N L N E L N E L Time Controller Twin Channel Demand Underfloor Controls Wiring Centre Page 46 Worcester wiring guide Greenstar gas-fired boilers Greenstar CDi Combi Zoned Radiator & Underfloor Heating The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral Greenstar CDi Combi E E = Earth = Live L L N N = Neutral E E = Earth Room T/Stat Radiators Zone N M ~ N E L 230V Mains Voltage Double Pole Fused Spur L N E L Radiators Zone Valve N NS LS LR L N E L N E 4 5 6 7 8 9 10 L N E L N E N L Time Controller Single Channel Worcester wiring guide Greenstar gas-fired boilers Demand Underfloor Controls Wiring Centre Page 47 Greenstar CDi Combi separate Time Controller & Room Thermostat The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N = Neutral N E E = Earth Series Connector Not supplied. Once wired in make connector safe in electrical cover. Greenstar CDi Combi L Room T/Stat N NS LS LR 230V Mains Voltage Double Pole Fused Spur L N E Time Controller Page 48 Worcester wiring guide Greenstar gas-fired boilers Greenstar CDi Combi Programmable Thermostat The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth Greenstar CDi Combi Programmable Thermostat L N NS LS LR N L C NC NO 230V Mains Voltage Double Pole Fused Spur L N E Worcester wiring guide Greenstar gas-fired boilers The Link between the Live (L) and Common (C) may already be fitted as part of the Programmable Thermostat, if not then a link must be fitted. Page 49 Greenstar CDi Combi Smartfit Control Pack The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth Greenstar CDi Combi L N NS LS LR SMARTFIT ROOM UNIT 230V Mains Voltage Double Pole Fused Spur MAINS L N E Smartfit Layout: Example shown S Plan configuration N SMARTFIT FROST PROTECTION ROOM UNIT A L BOILER L SL Y PLAN S PLAN PL N PUMP N L HW VALVE (S) CH VALVE (S) 3 PORT VALVE (Y) POLARITY FREE ACCESSORY PORT CYLINDER SENSOR HW VALVE (S) CH VALVE (S) Page 50 CYLINDER T/STAT Worcester wiring guide Greenstar gas-fired boilers Greenstar CDi Combi Cascade boilers with low loss header The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth NOTE A pump must be wired to each boiler for pump over-run to dissipate heat from within the boiler. The connections are pump live to Lz, pump neutral to Nz and pump earth to the Earth point of each boiler. HEADER LIMIT THERMOSTAT This cuts the Demand to the boilers in the event of excessive temperature within the Header due to lack of circulation. Ideally this should be set to 90ºC. Wiring from Zone/s Controls IMPORTANT NOTE: The Relay should be mounted within a suitable electrically safe housing. Junction Box/Wiring Centre L N Switched Live/ Demand E NO NC C Header Limit Thermostat C N O N C 230V AC Double Pole Relay C N NS LS LR NO C Coil Coil Live Neutral Example relay shown is a Double Pole Mains Voltage Relay. This isolates the Boilers electrically in case of a fault condition. C Greenstar CDi Combi L NC Greenstar CDi Combi L N NS LS LR 230V Mains Voltage Double Pole Fused Spur L N E Worcester wiring guide Greenstar gas-fired boilers Page 51 Greenstar CDi Combi Frost Protection The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth The boiler has inbuilt frost protection. When the primary temperature drops below 8°C the pump is switched on. When then temperature rises above 9°C the pump switches off after a 3 minute pump overrun. If the primary temperature drops below 5°C, a central heating demand is activated until the primary temperature rises above 12 °C. The demand switches off followed by the pump after a 3 minute overrun. The boiler has the facility to connect an external frost protection device to protect in “at risk areas” (terminal block ST6, contacts FS and FR). This is used if the boiler is not located in the area needing protection i.e. boiler in kitchen but pipe work in the garage that needs frost protection. If external frost thermostat is calling, i.e. temperature within frost thermostat below the set point, but the primary temperature of the boiler is above 5°C, the pump will run until the temperature within the frost thermostat rises above the set point. If external frost thermostat is calling and the primary temperature is below 5°C, a central heating demand is activated until primary temperature is above 12 °C. If the frost thermostat is still calling the pump will run until the temperature within the frost thermostat location rises above the set point. Frost T/Stat Greenstar CDi Combi FR FS NP LP L N NS LS LR 230V Mains Voltage Double Pole Fused Spur L N E Page 52 Worcester wiring guide Greenstar gas-fired boilers Greenstar FS CDi Regular 2 x 2 Port Valves (S Plan) The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E Greenstar FS CDi Regular L E = Earth = Live L L N N = Neutral E E N NS LS LR = Earth Room T/Stat N LZ NZ M ~ N E L Cylinder T/Stat Heating Zone Valve C 1 230V Mains Voltage Double Pole Fused Spur L N E L N E L N E 4 5 6 7 2 8 9 10 HW ON CH ON M L N E N External Pump ~ N E L Cylinder Zone Valve L Time Controller Worcester wiring guide Greenstar gas-fired boilers Page 53 Greenstar FS CDi Regular Mid Position Valve (Y Plan) The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E Greenstar FS CDi Regular L N NS LS LR E = Earth = Live L L N N = Neutral E E = Earth Mid Position Valve N LZ NZ Room T/Stat E Green/Yellow Blue White Grey Orange Cylinder T/Stat N C 1 N E L N E L N E External Pump CH ON L N E 4 5 6 7 8 9 10 HW OFF L HW ON 230V Mains Voltage Double Pole Fused Spur 2 N L Time Controller Page 54 Worcester wiring guide Greenstar gas-fired boilers Greenstar FS CDi Regular 3 x 2 Port Valves (S Plan Plus) The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth Greenstar FS CDi Regular L = Live L L N N = Neutral E E = Earth N NS LS LR LZ NZ M Room T/Stat Zone 1 E L Cylinder T/Stat N Heating Zone 1 Valve C 1 230V Mains Voltage Double Pole Fused Spur ~ N L N E L N E 4 5 6 7 2 8 9 10 L N E External Pump CH Zone 1 ON HW ON CH Zone 2 ON L N E M ~ N E L Cylinder Zone Valve N M N L E Time Controller 3 Channel N ~ L Heating Zone 2 Valve Room T/Stat Zone 2 Worcester wiring guide Greenstar gas-fired boilers Page 55 Greenstar FS CDi Regular 2 x Heating Zones The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral Greenstar FS CDi Regular L N NS LS LR E E = Earth = Live L L N N = Neutral E E = Earth LZ NZ M Room T/Stat Zone 1 E Room T/Stat Zone 2 N E L N E L N E 4 5 6 CH Zone 2 ON N CH Zone 1 ON L N E L N External Pump L Heating Zone 1 Valve N 230V Mains Voltage Double Pole Fused Spur ~ N 7 8 9 10 M ~ N E L Heating Zone 2 Valve L Time Controller Page 56 Worcester wiring guide Greenstar gas-fired boilers Greenstar FS CDi Regular 2 x 2 Port Valves & Underfloor Heating The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth Greenstar FS CDi Regular L N NS LS LR = Live L L N N = Neutral E E = Earth LZ NZ M Room T/Stat Zone 1 ~ N E L Cylinder T/Stat N Heating Zone 1 Valve C 2 1 N E L N E L N E 4 5 6 8 9 10 M ~ N E L Cylinder Zone Valve N External Pump 7 HW ON L N E L CH Zone 1 ON 230V Mains Voltage Double Pole Fused Spur L N E L N E L Time Controller Twin Channel Demand Underfloor Controls Wiring Centre Worcester wiring guide Greenstar gas-fired boilers Page 57 Greenstar FS CDi Regular Zoned Radiator & Underfloor Heating The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth Greenstar FS CDi Regular L N NS LS LR = Live L L N N = Neutral E E = Earth LZ NZ M Room T/Stat Radiators Zone ~ N E L N Radiators Zone Valve 230V Mains Voltage Double Pole Fused Spur L N E L N E External Pump Page 58 L N E L N E 4 5 6 N L Time Controller Single Channel 7 8 9 10 L N E L N E Demand Underfloor Controls Wiring Centre Worcester wiring guide Greenstar gas-fired boilers Greenstar FS CDi Regular Single Hot Water Zone (Vented Cylinder) The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N = Neutral N E E = Earth Greenstar FS CDi Regular L = Live L L N N = Neutral E E = Earth N NS LS LR Cylinder T/Stat LZ NZ C 2 1 230V Mains Voltage Double Pole Fused Spur L N E L N E L N E L N E 4 5 6 7 8 9 10 N L External Pump Worcester wiring guide Greenstar gas-fired boilers Time Controller Single Channel Page 59 Greenstar FS CDi Regular Single Heating Zone The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N = Neutral N E E = Earth Greenstar FS CDi Regular L N NS LS LR = Live L L N N = Neutral E E = Earth Room T/Stat LZ NZ N 230V Mains Voltage Double Pole Fused Spur L N E L N E L N E L N E 4 5 6 7 8 9 10 N L External Pump Page 60 Time Controller Single Channel Worcester wiring guide Greenstar gas-fired boilers Greenstar FS CDi Regular Grundfoss Pump Plan The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N = Neutral N E E = Earth IMPORTANT NOTE The pump over-run of the pump plan controls, causes the hot water pump to run regardless of the hot water cylinder demand, to dissipate boiler heat. Worcester would only recommend the Grundfoss pump plan system on a vented cylinder. Greenstar FS CDi Regular N NS LS LR L LZ NZ 230V Mains Voltage Double Pole Fused Spur Warning! 240V - Isolate electrical supply before removing wiring centre cover. L N E 2.5A Fuse - RS Components stock no 415-604 BOILER FUSE 2.5A N L N L S/L 1 Frost T/Stat FROST T/STAT (N/U) (if required) (N/U) 2 Demand N L NO N an d em C m an d (N/U) De 1 Cylinder T/Stat CYLINDER T/STAT C (N/U) L L N D 2 P/L N NO ROOM T/STAT Room T/Stat C N NO HW PUMP HW Pump N L CH PUMP CHPump N CH on HW on N L CH on PROGRAMMER HW on 4 (N/U) (N/U) CH/HW Programmer 3 1 (N/U) 2 L N/U = Not Used UPP 15-50 PUMP PLAN - WIRING CENTRE CONNECTIONS Worcester wiring guide Greenstar gas-fired boilers Page 61 Greenstar FS CDi Regular Smartfit Control Pack The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth Greenstar FS CDi Regular L N NS LS LR LZ NZ SMARTFIT ROOM UNIT 230V Mains Voltage Double Pole Fused Spur Smartfit Layout: Example shown S Plan configuration MAINS L N E BOILER PUMP L N E N SMARTFIT FROST PROTECTION ROOM UNIT A L L SL S PLAN POLARITY FREE Y PLAN PL N N L HW VALVE (S) CH VALVE (S) 3 PORT VALVE (Y) ACCESSORY PORT CYLINDER SENSOR External Pump HW VALVE (S) CH VALVE (S) Page 62 CYLINDER T/STAT Worcester wiring guide Greenstar gas-fired boilers Greenstar FS CDi Regular Cascaded boilers with low loss header The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth NOTE A pump must be wired to each boiler for pump over-run to dissipate heat from within the boiler. The connections are pump live to Lz, pump neutral to Nz and pump earth to the Earth point of each boiler. HEADER LIMIT THERMOSTAT This cuts the Demand to the boilers in the event of excessive temperature within the Header due to lack of circulation. Ideally this should be set to 90ºC. Wiring from Zone/s Controls IMPORTANT NOTE: The Relay should be mounted within a suitable electrically safe housing. Junction Box/Wiring Centre L N NO NC NC E C C Coil Live Header Limit Thermostat C Greenstar FS CDi Regular L NO Switched Live/ Demand N O N C 230V AC Double Pole Relay C N NS LS LR C Coil Neutral Example relay shown is a Double Pole Mains Voltage Relay. This isolates the Boilers electrically in case of a fault condition. Greenstar FS CDi Regular L N NS LS LR LZ NZ LZ NZ 230V Mains Voltage Double Pole Fused Spur L N E L N E Shunt Pump Worcester wiring guide Greenstar gas-fired boilers L N E Shunt Pump Page 63 Greenstar FS CDi Regular Frost Protection The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth The boiler has inbuilt frost protection. When the primary temperature drops below 8°C the pump is switched on. When then temperature rises above 9°C the pump switches off after a 3 minute pump overrun. If the primary temperature drops below 5°C, a central heating demand is activated until the primary temperature rises above 12 °C. The demand switches off followed by the pump after a 3 minute overrun. The boiler has the facility to connect an external frost protection device to protect in “at risk areas” (terminal block ST6, contacts FS and FR). This is used if the boiler is not located in the area needing protection i.e. boiler in kitchen but pipe work in the garage that needs frost protection. If external frost thermostat is calling, i.e. temperature within frost thermostat below the set point, but the primary temperature of the boiler is above 5°C, the pump will run until the temperature within the frost thermostat rises above the set point. If external frost thermostat is calling and the primary temperature is below 5°C, a central heating demand is activated until primary temperature is above 12 °C. If the frost thermostat is still calling the pump will run until the temperature within the frost thermostat location rises above the set point. Greenstar FS CDi Regular 230V Mains Voltage L = Live L L N N = Neutral E E = Earth N NS LS LR LZ NZ Double Pole Fused Spur Earth to Wiring Centre L N E Neutral Feed to Wiring Centre Live Feed to Wiring Centre Switch Live from Wiring Centre FR FS NP LP Frost Stat L N E E External Pump Page 64 Worcester wiring guide Greenstar gas-fired boilers Greenstar HF CDi combi 2 x Heating Zones The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N = Neutral N E = Earth E 230V Mains Voltage Double Pole Fused Spur Greenstar HF CDi L N NS LS LR = Live L L N N = Neutral E E = Earth L N E 230V HW interface ‘Installer Module’ M Room T/Stat Zone 1 Safety isolation N E Room T/Stat Zone 2 N NC L N E HW ON 4 5 6 CH Zone 2 ON E CH Zone 1 ON N N L Heating Zone 1 Valve N L ~ N 7 8 9 10 M ~ N E L Heating Zone 2 Valve L Time Controller 3 Channel Worcester wiring guide Greenstar gas-fired boilers Page 65 Greenstar HF CDi combi Zoned Radiator & Underfloor Heating The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N = Neutral N E E = Earth 230V Mains Voltage Double Pole Fused Spur Greenstar HF CDi L N NS LS LR = Live L L N N = Neutral E E = Earth L N E 230V HW interface ‘Installer Module’ M Room T/Stat Radiators Zone Safety isolation N ~ N E L N NC Radiators Zone Valve N E L N E 4 5 CH Rads ON HW Heat Bank ON L N 6 7 8 9 10 L N E L N E Demand Underfloor Controls Wiring Centre L Time Controller Page 66 Worcester wiring guide Greenstar gas-fired boilers Greenstar HF CDi combi separate Time Controller & Room Thermostat The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral 230V Mains Voltage Double Pole Fused Spur E E = Earth Greenstar HF CDi L N NS LS LR L N E Room T/Stat 230V HW interface ‘Installer Module’ Safety isolation N Series Connector Not supplied. Once wired in make connector safe in electrical cover. HW Heat Bank ON CH ON NC Time Controller Worcester wiring guide Greenstar gas-fired boilers Page 67 Greenstar HF CDi combi Programmable Thermostat The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth Programmable Thermostat 230V Mains Voltage Double Pole Fused Spur Greenstar HF CDi L N NS LS LR N L C NC NO L N E 230V HW interface ‘Installer Module’ Safety isolation N HW Heat Bank ON NC The Link between the Live (L) and Common (C) may already be fitted as part of the Programmable Thermostat, if not then a link must be wired in. Time Controller Hot Water Heat Bank Page 68 Worcester wiring guide Greenstar gas-fired boilers Greenstar HF CDi combi Large heating circuit with low loss header The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth If the heating system requires a larger pump to circulate the water, then a header can be used to prevent the boiler and system pump from conflicting with each other. NOTE The system pump is wired with the heating demand so it will only activate when the heating is called for. Size the system pump according to system design specifications and water content. HEADER LIMIT THERMOSTAT This cuts the Demand to the boiler in the event of excessive temperature within the header due to lack of circulation. Ideally this should be set to 90ºC. 230V Mains Voltage = Live L L N N = Neutral E E Room T/Stat = Earth Greenstar HF CDi Double Pole Fused Spur L N NS LS LR C Header Limit Thermostat N L N E N C O 230V HW interface ‘Installer Module’ Safety isolation L N N E 4 5 6 7 8 9 10 NC HW Heat Bank ON CH ON E Time Controller Worcester wiring guide Greenstar gas-fired boilers L N E E System Pump Page 69 Greenstar HF CDi combi Frost Protection The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth The boiler has inbuilt frost protection. When the primary temperature drops below 8°C the pump is switched on. When then temperature rises above 9°C the pump switches off after a 3 minute pump overrun. If the primary temperature drops below 5°C, a central heating demand is activated until the primary temperature rises above 12 °C. The demand switches off followed by the pump after a 3 minute overrun. The boiler has the facility to connect an external frost protection device to protect in “at risk areas” (terminal block ST6, contacts FS and FR). This is used if the boiler is not located in the area needing protection i.e. boiler in kitchen but pipe work in the garage that needs frost protection. If external frost thermostat is calling, i.e. temperature within frost thermostat below the set point, but the primary temperature of the boiler is above 5°C, the pump will run until the temperature within the frost thermostat rises above the set point. If external frost thermostat is calling and the primary temperature is below 5°C, a central heating demand is activated until primary temperature is above 12 °C. If the frost thermostat is still calling the pump will run until the temperature within the frost thermostat location rises above the set point. Greenstar HF CDi L Frost T/Stat N NS LS LR 230V Mains Voltage Double Pole Fused Spur L N E 230V HW interface ‘Installer Module’ Safety isolation N NC FR FS NP LP Page 70 Worcester wiring guide Greenstar gas-fired boilers Greenstar Si Combi 2 x 2 Port Valves (S Plan) The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth Greenstar Si Combi L N N = Neutral E E = Earth M Room T/Stat E L N E L Cylinder T/Stat Heating Zone Valve C N NS LS LR 1 230V Mains Voltage Double Pole Fused Spur ~ N N L = Live L L N E L N E 4 5 6 7 2 8 9 10 HW ON CH ON M N ~ N E L Cylinder Zone Valve L Time Controller Worcester wiring guide Greenstar gas-fired boilers Page 71 Greenstar Si Combi Mid Position Valve (Y Plan) The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth = Live L L N N = Neutral E E Mid Position Valve = Earth N Greenstar Si Combi Room T/Stat E Green/Yellow Blue White Grey Orange Cylinder T/Stat N C L N E L N E 4 CH ON L N E 1 5 6 7 2 8 9 10 HW OFF 230V Mains Voltage Double Pole Fused Spur N NS LS LR HW ON L N L Time Controller Page 72 Worcester wiring guide Greenstar gas-fired boilers Greenstar Si Combi 3 x 2 Port Valves (S Plan Plus) The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth Greenstar Si Combi = Live L L N N = Neutral E E = Earth M Room T/Stat Zone 1 E Heating Zone 1 Valve C N NS LS LR 1 L N E L N E L N E 4 CH Zone 1 ON HW ON 5 6 7 2 8 9 10 M CH Zone 2 ON 230V Mains Voltage Double Pole Fused Spur L Cylinder T/Stat N L ~ N ~ N E L Cylinder Zone Valve N M ~ N L E Time Controller 3 Channel N L Heating Zone 2 Valve Room T/Stat Zone 2 Worcester wiring guide Greenstar gas-fired boilers Page 73 Greenstar Si Combi 2 x Heating Zones The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth Greenstar Si Combi = Live L L N N = Neutral E E = Earth M Room T/Stat Zone 1 E Room T/Stat Zone 2 N L N E L N E 4 5 6 CH Zone 2 ON L N E N NS LS LR CH Zone 1 ON 230V Mains Voltage Double Pole Fused Spur N L Heating Zone 1 Valve N L ~ N 7 8 9 10 M ~ N E L Heating Zone 2 Valve L Time Controller Page 74 Worcester wiring guide Greenstar gas-fired boilers Greenstar Si Combi 2 x 2 Port Valves & Underfloor Heating The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth = Live L L N N = Neutral E E = Earth Room T/Stat Zone 1 Greenstar Si Combi M ~ N N E L Cylinder T/Stat L 2 1 N E L N E 4 5 6 7 8 9 10 M ~ N HW ON L N E L CH Zone 1 ON 230V Mains Voltage Double Pole Fused Spur Heating Zone 1 Valve C N NS LS LR E L Cylinder Zone Valve N L N E L N E L Time Controller Twin Channel Demand Underfloor Controls Wiring Centre Worcester wiring guide Greenstar gas-fired boilers Page 75 Greenstar Si Combi Zoned Radiator & Underfloor Heating The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral Greenstar Si Combi E E = Earth = Live L L N N = Neutral E E = Earth M Room T/Stat Radiators Zone ~ N E L N L 230V Mains Voltage Double Pole Fused Spur Radiators Zone Valve N NS LS LR L N E L N E 4 5 6 7 8 9 10 CH ON L N E L N E L N E N L Time Controller Single Channel Page 76 Demand Underfloor Controls Wiring Centre Worcester wiring guide Greenstar gas-fired boilers Greenstar Si Combi separate Time Controller & Room Thermostat The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N = Neutral N E E = Earth Series Connector Not supplied. Once wired in, make connector safe in electrical cover. Room T/Stat Greenstar Si Combi N NS LS LR 230V Mains Voltage Double Pole Fused Spur CH ON L L N E Time Controller Worcester wiring guide Greenstar gas-fired boilers Page 77 Greenstar Si Combi Programmable Thermostat The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth Greenstar Si Combi L N NS LS LR Programmable Thermostat N L C NC NO 230V Mains Voltage Double Pole Fused Spur L N E Page 78 The Link between the Live (L) and Common (C) may already be fitted as part of the Programmable Thermostat, if not then a link must be wired in. Worcester wiring guide Greenstar gas-fired boilers Greenstar Si Combi Smartfit Control Pack The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth Greenstar Si Combi L N NS LS LR SMARTFIT ROOM UNIT 230V Mains Voltage Double Pole Fused Spur MAINS L N E Smartfit Layout: Example shown S Plan configuration N SMARTFIT FROST PROTECTION ROOM UNIT A L BOILER L SL S PLAN Y PLAN PL N PUMP N L HW VALVE (S) CH VALVE (S) 3 PORT VALVE (Y) POLARITY FREE ACCESSORY PORT CYLINDER SENSOR HW VALVE (S) CH VALVE (S) Worcester wiring guide Greenstar gas-fired boilers CYLINDER T/STAT Page 79 Greenstar Si Combi Cascaded boilers with low loss header The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth HEADER LIMIT THERMOSTAT This cuts the Demand to the boilers in the event of excessive temperature within the Header due to lack of circulation. Ideally this should be set to 90º C. Wiring from Zone/s Controls IMPORTANT NOTE: The Relay should be mounted within a suitable electrically safe housing. Junction Box/Wiring Centre L N Switched Live/ Demand E NO NC C Header Limit Thermostat C N O N C 230V AC Double Pole Relay C N NS LS LR NO C Coil Coil Live Neutral Example relay shown is a Double Pole Mains Voltage Relay. This isolates the Boilers electrically in case of a fault condition. C Greenstar Si Combi Greenstar Si Combi L NC L N NS LS LR 230V Mains Voltage Double Pole Fused Spur L N E Page 80 Worcester wiring guide Greenstar gas-fired boilers Greenstar Si Combi Frost Protection The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth The boiler has inbuilt frost protection. When the primary temperature drops below 8°C the pump is switched on. When then temperature rises above 9°C the pump switches off after a 3 minute pump overrun. If the primary temperature drops below 5°C, a central heating demand is activated until the primary temperature rises above 12 °C. The demand switches off followed by the pump after a 3 minute overrun. The boiler has the facility to connect an external frost protection device to protect in “at risk areas” (terminal block ST6, contacts FS and FR). This is used if the boiler is not located in the area needing protection i.e. boiler in kitchen but pipe work in the garage that needs frost protection. If external frost thermostat is calling, i.e. temperature within frost thermostat below the set point, but the primary temperature of the boiler is above 5°C, the pump will run until the temperature within the frost thermostat rises above the set point. If external frost thermostat is calling and the primary temperature is below 5°C, a central heating demand is activated until primary temperature is above 12 °C. If the frost thermostat is still calling the pump will run until the temperature within the frost thermostat location rises above the set point. Frost T/Stat Greenstar Si Combi FR FS NP LP L N NS LS LR 230V Mains Voltage Double Pole Fused Spur L N E Worcester wiring guide Greenstar gas-fired boilers Page 81 Greenstar i Junior Combi 2 x 2 Port Valves (S Plan) The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth Greenstar i Jnr Combi L N N = Neutral E E = Earth M Room T/Stat E L N E L Cylinder T/Stat Heating Zone Valve C N NS LS LR 1 230V Mains Voltage Double Pole Fused Spur ~ N N L = Live L L N E L N E 4 5 6 7 2 8 9 10 HW ON CH ON M N ~ N E L Cylinder Zone Valve L Time Controller Page 82 Worcester wiring guide Greenstar gas-fired boilers Greenstar i Junior Combi Mid Position Valve (Y Plan) The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth = Live L L N N = Neutral E E Mid Position Valve = Earth N Greenstar i Jnr Combi Room T/Stat E Green/Yellow Blue White Grey Orange Cylinder T/Stat N C L N E L N E 4 CH ON L N E 1 5 6 7 2 8 9 10 HW OFF 230V Mains Voltage Double Pole Fused Spur N NS LS LR HW ON L N L Time Controller Worcester wiring guide Greenstar gas-fired boilers Page 83 Greenstar i Junior Combi 3 x 2 Port Valves (S Plan Plus) The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth Greenstar i Jnr Combi = Live L L N N = Neutral E E = Earth M Room T/Stat Zone 1 E Heating Zone 1 Valve C N NS LS LR 1 L N E L N E L N E 4 5 6 7 2 8 CH Zone 1 ON HW ON 9 10 M CH Zone 2 ON 230V Mains Voltage Double Pole Fused Spur L Cylinder T/Stat N L ~ N ~ N E L Cylinder Zone Valve N M ~ N L E Time Controller 3 Channel N L Heating Zone 2 Valve Room T/Stat Zone 2 Page 84 Worcester wiring guide Greenstar gas-fired boilers Greenstar i Junior Combi 2 x Heating Zones The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth Greenstar i Jnr Combi = Live L L N N = Neutral E E = Earth M Room T/Stat Zone 1 E Room T/Stat Zone 2 N L N E L N E 4 5 6 CH Zone 2 ON L N E N NS LS LR CH Zone 1 ON 230V Mains Voltage Double Pole Fused Spur N L Heating Zone 1 Valve N L ~ N 7 8 9 10 M ~ N E L Heating Zone 2 Valve L Time Controller Worcester wiring guide Greenstar gas-fired boilers Page 85 Greenstar i Junior Combi 2 x 2 Port Valves & Underfloor Heating The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth = Live L L N N = Neurtal E E = Earth Room T/Stat Zone 1 Greenstar i Jnr Combi M ~ N N E L Cylinder T/Stat L 2 1 N E L N E 4 5 6 7 8 9 10 M ~ N HW ON L N E L CH Zone 1 ON 230V Mains Voltage Double Pole Fused Spur Heating Zone 1 Valve C N NS LS LR E L Cylinder Zone Valve N L N E L N E L Time Controller Twin Channel Demand Underfloor Controls Wiring Centre Page 86 Worcester wiring guide Greenstar gas-fired boilers Greenstar i Junior Combi Zoned Radiator & Underfloor Heating The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral Greenstar i Jnr Combi E E = Earth = Live L L N N = Neutral E E = Earth M Room T/Stat Radiators Zone ~ N E L N L 230V Mains Voltage Double Pole Fused Spur Radiators Zone Valve N NS LS LR L N E L N E 4 5 6 7 8 9 10 CH ON L N E L N E L N E N L Time Controller Single Channel Worcester wiring guide Greenstar gas-fired boilers Demand Underfloor Controls Wiring Centre Page 87 Greenstar i Junior Combi separate Time Controller & Room Thermostat The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N = Neutral N E E = Earth Series Connector Not supplied. Once wired in, make connector safe in electrical cover. Room T/Stat Greenstar i Jnr Combi 230V Mains Voltage Double Pole Fused Spur N NS LS LR CH ON L L N E Time Controller Page 88 Worcester wiring guide Greenstar gas-fired boilers Greenstar i Junior Combi Programmable Thermostat The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth Greenstar i Jnr Combi L N NS LS LR Programmable Thermostat N L C NC NO 230V Mains Voltage Double Pole Fused Spur L N E Worcester wiring guide Greenstar gas-fired boilers The Link between the Live (L) and Common (C) may already be fitted as part of the Programmable Thermostat, if not then a link must be wired in. Page 89 Greenstar i Junior combi Smartfit Control Pack The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth Greenstar i Jnr Combi L N NS LS LR SMARTFIT ROOM UNIT 230V Mains Voltage Smartfit Layout: Example shown S Plan configuration Double Pole Fused Spur MAINS L N E N SMARTFIT FROST PROTECTION ROOM UNIT A L BOILER L SL S PLAN Y PLAN PL N PUMP N L HW VALVE (S) CH VALVE (S) 3 PORT VALVE (Y) POLARITY FREE ACCESSORY PORT CYLINDER SENSOR HW VALVE (S) CH VALVE (S) Page 90 CYLINDER T/STAT Worcester wiring guide Greenstar gas-fired boilers Greenstar i Junior combi Cascade boilers with low loss header The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth HEADER LIMIT THERMOSTAT This cuts the Demand to the boilers in the event of excessive temperature within the Header due to lack of circulation. Ideally this should be set to 90º C. Wiring from Zone/s Controls IMPORTANT NOTE: The Relay should be mounted within a suitable electrically safe housing. Junction Box/Wiring Centre L N Switched Live/ Demand E NO NC C Header Limit Thermostat C N O N C 230V AC Double Pole Relay C N NS LS LR NO C Coil Coil Live Neutral Example relay shown is a Double Pole Mains Voltage Relay. This isolates the Boilers electrically in case of a fault condition. C Greenstar i Jnr Combi Greenstar i jnr Combi L NC L N NS LS LR 230V Mains Voltage Double Pole Fused Spur L N E Worcester wiring guide Greenstar gas-fired boilers Page 91 Greenstar i Junior combi Frost Protection The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth The boiler has inbuilt frost protection. When the primary temperature drops below 8°C the pump is switched on. When then temperature rises above 9°C the pump switches off after a 3 minute pump overrun. If the primary temperature drops below 5°C, a central heating demand is activated until the primary temperature rises above 12 °C. The demand switches off followed by the pump after a 3 minute overrun. The boiler has the facility to connect an external frost protection device to protect in “at risk areas” (terminal block ST6, contacts FS and FR). This is used if the boiler is not located in the area needing protection i.e. boiler in kitchen but pipe work in the garage that needs frost protection. If external frost thermostat is calling, i.e. temperature within frost thermostat below the set point, but the primary temperature of the boiler is above 5°C, the pump will run until the temperature within the frost thermostat rises above the set point. If external frost thermostat is calling and the primary temperature is below 5°C, a central heating demand is activated until primary temperature is above 12 °C. If the frost thermostat is still calling the pump will run until the temperature within the frost thermostat location rises above the set point. Frost T/Stat Greenstar i Jnr Combi FR FS NP LP L N NS LS LR 230V Mains Voltage Double Pole Fused Spur L N E Page 92 Worcester wiring guide Greenstar gas-fired boilers Greenstar i System 2 x 2 Port Valves (S Plan) The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth = Live L L N N = Neutral E E Greenstar i System = Earth M Room T/Stat E L N E Heating Zone Valve C N NS LS LR 1 230V Mains Voltage Double Pole Fused Spur L Cylinder T/Stat N L ~ N L N E L N E 4 5 6 7 2 8 9 10 HW ON CH ON M N ~ N E L Cylinder Zone Valve L Time Controller Worcester wiring guide Greenstar gas-fired boilers Page 93 Greenstar i System Mid Position Valve (Y Plan) The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth = Live L L N N = Neutral E E = Earth Mid Position Valve N Greenstar i System Room T/Stat E Green/Yellow Blue White Grey Orange Cylinder T/Stat N C L N E L N E 4 CH ON L N E 1 5 6 7 2 8 9 10 HW OFF 230V Mains Voltage Double Pole Fused Spur N NS LS LR HW ON L N L Time Controller Page 94 Worcester wiring guide Greenstar gas-fired boilers Greenstar i System 3 x 2 Port Valves (S Plan Plus) The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth Greenstar i System = Live L L N N = Neutral E E = Earth M Room T/Stat Zone 1 E Heating Zone 1 Valve C N NS LS LR 1 L N E L N E L N E 4 CH Zone 1 ON HW ON 5 6 7 2 8 9 10 M CH Zone 2 ON 230V Mains Voltage Double Pole Fused Spur L Cylinder T/Stat N L ~ N ~ N E L Cylinder Zone Valve N M ~ N L E Time Controller 3 Channel N L Heating Zone 2 Valve Room T/Stat Zone 2 Worcester wiring guide Greenstar gas-fired boilers Page 95 Greenstar i System 2 x Heating Zones The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth Greenstar i System = Live L L N N = Neutral E E = Earth M Room T/Stat Zone 1 E Room T/Stat Zone 2 N L N E L N E 4 5 6 CH Zone 2 ON L N E N NS LS LR CH Zone 1 ON 230V Mains Voltage Double Pole Fused Spur N L Heating Zone 1 Valve N L ~ N 7 8 9 10 M ~ N E L Heating Zone 2 Valve L Time Controller Page 96 Worcester wiring guide Greenstar gas-fired boilers Greenstar i System 2 x 2 Port Valves & Underfloor Heating The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth Greenstar i System = Live L L N N = Neutral E E = Earth M Room T/Stat Zone 1 E N NS LS LR 2 N E L N E 4 5 6 7 8 9 10 M ~ N HW ON L CH Zone 1 ON L N E Heating Zone 1 Valve C 1 230V Mains Voltage Double Pole Fused Spur L Cylinder T/Stat N L ~ N E L Cylinder Zone Valve N L N E L N E L Time Controller Twin Channel Demand Underfloor Controls Wiring Centre Worcester wiring guide Greenstar gas-fired boilers Page 97 Greenstar i System Zoned Radiator & Underfloor Heating The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral Greenstar i System E E = Earth = Live L L N N = Neutral E E = Earth M Room T/Stat Radiators Zone ~ N E L N 230V Mains Voltage Double Pole Fused Spur L N E L = Live L N E L N E 4 5 6 CH ON L Radiators Zone Valve N NS LS LR N L Time Controller Single Channel Page 98 7 8 9 10 L N E L N E N = Neurtal E = Earth Demand Underfloor Controls Wiring Centre Worcester wiring guide Greenstar gas-fired boilers Greenstar i System Single Hot Water Zone (Vented Cylinder) The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N = Neutral N E E = Earth = Live L L N N = Neutral E E = Earth Cylinder T/Stat Greenstar i System C 2 1 L N NS LS LR 230V Mains Voltage Double Pole Fused Spur L N E L N E L N E 4 5 6 7 8 9 10 N L Time Controller Single Channel Worcester wiring guide Greenstar gas-fired boilers Page 99 Greenstar i System Single Heating Zone The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N = Neutral N E E = Earth L N N = Neutral E E 230V Mains Voltage Double Pole Fused Spur L N E = Earth Room T/Stat Greenstar i System L = Live L N N NS LS LR L N E L N E 4 5 6 7 8 9 10 N L Time Controller Single Channel Page 100 Worcester wiring guide Greenstar gas-fired boilers Greenstar i System Smartfit Control Pack The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth Greenstar i System L N NS LS LR SMARTFIT ROOM UNIT 230V Mains Voltage Double Pole Fused Spur MAINS L N E Smartfit Layout: Example shown S Plan configuration N SMARTFIT FROST PROTECTION ROOM UNIT A L BOILER L SL S PLAN POLARITY FREE Y PLAN PL N PUMP N L HW VALVE (S) CH VALVE (S) 3 PORT VALVE (Y) ACCESSORY PORT CYLINDER SENSOR HW VALVE (S) CH VALVE (S) Worcester wiring guide Greenstar gas-fired boilers CYLINDER T/STAT Page 101 Greenstar i System Internal Diverter Valve with Worcester Controls & Unvented Cylinder The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth There is a unclarity within the Industry that in order to protect an Unvented Hot Water Cylinder from potentially dangerous high temperatures from the boiler circuit, a 2-port motorised valve must be installed. This is not the case, although it is the most common interpretation and approach. FURTHER DETAILS Building Regulation Approved Document G3, paragraph 3.6 states '…the non-self-resetting thermal cut out should be wired to a motorised valve or some other suitable device to shut off the flow to the primary heater…'. The latter part of this sentence can be interpreted to mean as long as we, as responsible Manufacturer's, are confident our method provides an equal amount of protection to the common approach, we may instruct installers of our equipment to follow a different approach. A summary is provided below. G The installer will use the cylinder sensor supplied with the Integral Diverter Valve kit to control the hot water temperature. G The installer, therefore, will NOT need to use the hot water control thermostat of the cylinder's dual thermostat. G The installer may have to alter the wiring of the dual thermostat (depending on cylinder and thermostat manufacturer) to only use the high limit thermal cut-out of the dual thermostat. G The high limit thermal cut out of the dual thermostat MUST be wired to interrupt the permanent live to the Greenstar CDi System Boiler. G The 2-port valve supplied with the unvented cylinder will NOT be used. If it is already physically installed in the pipe work is should be removed and electrically disconnected from the wiring centre. Below you will find an electrical diagram for this arrangement. Optional: Third Party Room Thermostat: Using the Worcester Internal DT20 Timer an External Third Party Room Thermostat must be connected to the boiler on the External Controls section of ST10 (NS, LS & LR). DUAL THERMOSTAT 230V MAINS SUPPLY SAFETY LIMIT THERMOSTAT N E L Brown OPTIONAL: THIRD PARTY ROOM THERMOSTAT COM (made safe) CYLINDER THERMOSTAT Brown Blue CALL Connector Block Green\Yellow N ST8 9 8 LR LS NS N L FR FS NP LP ST10 7 NOTE: Leave the link if using Worcester Internal Digital RF units. ST6 Pump Harness Fan Harness FR FS NP LP L N NS LS LR 9 8 7 S11 2.5 A 230 V AC DIVERTER VALVE MOTOR PLUG Main Harness S12 0.5 A S13 1.6 A Code Plug Page 102 Worcester wiring guide Greenstar gas-fired boilers Greenstar i System Cascade boilers with low loss header The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth HEADER LIMIT THERMOSTAT This cuts the Demand to the boilers in the event of excessive temperature within the Header due to lack of circulation. Ideally this should be set to 90º C. Wiring from Zone/s Controls IMPORTANT NOTE: The Relay should be mounted within a suitable electrically safe housing. Junction Box/Wiring Centre L N Switched Live/ Demand E N C 230V AC Double Pole Relay C N NS LS LR NC NO C Coil Coil Live Neutral Example relay shown is a Double Pole Mains Voltage Relay. This isolates the Boilers electrically in case of a fault condition. C Greenstar i System L NC C Header Limit Thermostat C N O NO Greenstar i System L N NS LS LR 230V Mains Voltage Double Pole Fused Spur L N E Worcester wiring guide Greenstar gas-fired boilers Page 103 Greenstar i System Frost Protection The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth The boiler has inbuilt frost protection. When the primary temperature drops below 8°C the pump is switched on. When then temperature rises above 9°C the pump switches off after a 3 minute pump overrun. If the primary temperature drops below 5°C, a central heating demand is activated until the primary temperature rises above 12 °C. The demand switches off followed by the pump after a 3 minute overrun. The boiler has the facility to connect an external frost protection device to protect in “at risk areas” (terminal block ST6, contacts FS and FR). This is used if the boiler is not located in the area needing protection i.e. boiler in kitchen but pipe work in the garage that needs frost protection. If external frost thermostat is calling, i.e. temperature within frost thermostat below the set point, but the primary temperature of the boiler is above 5°C, the pump will run until the temperature within the frost thermostat rises above the set point. If external frost thermostat is calling and the primary temperature is below 5°C, a central heating demand is activated until primary temperature is above 12 °C. If the frost thermostat is still calling the pump will run until the temperature within the frost thermostat location rises above the set point. Frost T/Stat Greenstar i System FR FS NP LP L 230V Mains Voltage Double Pole Fused Spur L N E Page 104 N NS LS LR Earth to Wiring Centre Neutral Feed to Wiring Centre Live Feed to Wiring Centre Switch Live from Wiring Centre Worcester wiring guide Greenstar gas-fired boilers Worcester wiring guide Greenstar gas-fired boilers Page 105 Worcester wiring guide Greenstar gas-fired boilers Page 106 Useful Numbers The generic Live, Neutral and Earth feed/s to equipment must return to the respective connection on the wiring centre. These connections are denoted as follows: L L = Live N N = Neutral E E = Earth Sales Tel: 01905 752640 Contracts Tel: 0844 892 2332 sales.mailbox@uk.bosch.com service-contract.worcester@uk.bosch.com Spare Parts Tel: 01905 752576 Contact Centre Tel: 0844 892 3000 spares.mailbox@uk.bosch.com general.worcester@uk.bosch.com Training Tel: 01905 752526 Monday – Friday 7.00am – 8.00pm Saturday 8.00am – 5.00pm Sunday 9.00am – 12 noon training@uk.bosch.com Literature Tel: 0844 892 9800 literature@uk.bosch.com or download instantly from our website Technical Support Tel: 0844 892 3366 technical.enquiries@uk.bosch.com Monday – Friday 7.00am – 8.00pm Saturday 8.30am – 4.00pm www.worcester-bosch.co.uk Calls to the listed 0844 numbers are charged at up to 3 pence per minute from BT landlines. Calls from mobiles and some networks may vary. Calls to and from Bosch Thermotechnology Ltd. may be recorded for training and quality assurance purposes. Worcester, Bosch Group is a brand name of Bosch Thermotechnology Ltd. This is leaflet is accurate at the date of printing, buy may be superseded and should be disregarded if specification and/or appearances are changed in the interest of continued improvement. The statutory rights of the consumer are not affected. 6 720 646 965 Issue A (09/11) Worcester, Bosch Group, Cotswold Way, Warndon, Worcester, WR4 9SW. Tel: 0844 892 9900