AT TACHMENTS C15 / C18 Integral and Sub-Base Fuel Tanks US Sourced Diesel Generator Set 320 – 600 kW 60 Hz Image shown may not reflect actual package. FEATURES • UL listed for United States (UL 142) and Canada (ULC S601) • Compliant with NFPA 30, 37 & 110 and CSA C282-09 & B139-09 standards. • Dual wall • Lockable fuel fill cap, 4” (101.6mm) NPT • Fuel fill drop tube with in 6” (152mm) from bottom of tank • Low fuel level warning standard, customer configurable warning or shutdown • Primary tank leak detection switch in containment basin • Tank design provides capacity for thermal expansion of fuel • Fuel supply dip tube is positioned so as not to pick up fuel sediment • Fuel return and supply dip tube is separated by an internal baffle to prevent immediate re-supply of heated return fuel • Pressure washed with an iron phosphate solution • Interior tank surfaces coated with a solvent-based thin-film rust preventative • Heavy guage steel gussets with internal lifting rings • Primary and secondary tanks are leak tested at 20.7 kPa (3 psi) minimum • Compatible with open packages and enclosures • Gloss black polyester alkyd enamel exterior paint • Welded steel containment basin (minimum of 110% of primary tank capacity) • Direct reading fuel gauge with variable electrical output • Emergency vents on primary and secondary tanks are sized in accordance with NFPA 30 LEHE0467-01 DESCRIPTION – Sub Base The sub-base fuel tank mounts below the generator set wide base • DESCRIPTION – Integral • • Integral diesel fuel tank is incorporated into the generator set base frame Robust base design includes linear vibtration isolators between tank base and engine generator OPTIONS • Audio/visual fuel level alarm panel • 5 gal (18.9 L ) spill containment • Overfill prevention valve AT TACHMENTS INTEGRAL & SUB-BASE FUEL TANK BASE USEABLE CAPACITIES with Fuel Tank Dimensions & Weights Integral – Width (W) 2014 mm (79.3 in) Sub-base – Width (W) 2056 mm (81 in) OPEN SET & WEATHER PROTECTIVE ENCLOSURE C15 Tank Design Feature Code Total Capacity Useable Capacity TANK ONLY Liter Gallon Liter Gallon kg lb mm in mm in mm in mm in Integral FTDW002 1261 333 1215 321 1015 2,237 635 25 3814 150.1 2426 95.5 3200 126.0 Dry Weight Height ‘H’ TANK AND PACKAGE Length ‘L’ Open Pgs Height Enc. Pgs Height Sub-Base FTDW0010 2763 730 2498 660 1468 3,236 635 25 3810 150.0 2766 108.9 3537 139.3 Sub-Base FTDW005 3921 1036 3793 1002 1659 3,657 635 25 5550 218.5 2766 108.9 3537 139.3 Sub-Base FTDW006 7192 1900 7022 1855 2228 4,912 889 35 6184 243.5 3020 118.9 3793 149.3 C18 Tank Design Feature Code Liter Gallon Liter Gallon kg lb mm in mm in mm in mm in Integral FTDW004 1457 385 1400 370 1060 2,337 635 25 3814 150.1 2400 94.5 3200 126.0 Total Capacity Useable Capacity TANK ONLY Dry Weight Height ‘H’ TANK AND PACKAGE Length ‘L’ Open Pgs Height Enc. Pgs Height Sub-Base FTDW0010 2763 730 2498 660 1468 3,236 635 25 3810 150.0 2740 107.9 3537 139.3 Sub-Base FTDW005 3922 1036 3793 1002 1659 3,657 635 25 5550 218.5 2740 107.9 3537 139.3 Sub-Base FTDW007 8384 2215 8176 2160 2150 4,134 889 35 7073 278.5 2994 117.9 3793 149.3 INTEGRAL & SUB-BASE FUEL TANK BASE USEABLE CAPACITIES with Fuel Tank Dimensions & Weights Integral – Width (W) 2014 mm (79.3 in) Sub-base – Width (W) 2056 mm (81 in) SOUND ATTENUATED ENCLOSURE C15 Tank Design Feature Code Liter Gallon Liter Gallon kg lb mm in mm in mm in mm in Integral FTDW001 1261 333 1215 321 1015 2,237 635 25 4753 187.1 NA NA 2619 103.1 Sub-Base FTDW0011 2763 730 2498 660 1468 3,236 635 25 4743 186.7 NA NA 2955 116.3 Sub-Base FTDW005 3922 1036 3793 1002 1659 3,657 635 25 5550 218.5 NA NA 2955 116.3 Sub-Base FTDW006 7192 1900 7022 1855 2228 4,912 889 35 6184 243.5 NA NA 3209 126.3 C18 Tank Design Feature Code Liter Gallon Liter Gallon kg lb mm in mm in mm in mm in Integral FTDW003 1457 385 1400 370 1060 2,337 635 25 4753 187.1 NA NA 2557 100.7 Sub-Base FTDW0011 2763 730 2498 660 1468 3,236 635 25 4743 186.7 NA NA 2897 114.1 Sub-Base FTDW005 3921 1036 3793 1002 1659 3,657 635 25 5550 218.5 NA NA 2897 114.1 Sub-Base FTDW007 8384 2215 8176 2160 2150 4,740 889 35 7073 278.5 NA NA 3155 124.2 LEHE0467-01 Total Capacity Useable Capacity TANK ONLY Dry Weight Total Capacity Useable Capacity Height ‘H’ TANK AND PACKAGE Length ‘L’ TANK ONLY Dry Weight 2 Height ‘H’ Open Pgs Height Enc. Pgs Height TANK AND PACKAGE Length ‘L’ Open Pgs Height Enc. Pgs Height AT TACHMENTS The heights listed above do not include lumber used during manufacturing and shipping. ESTIMATED RUN TIMES (HOURS) AT 100% LOAD C15 Tank Design Feature Code Standby Ratings (ekW) 500 450 Prime Ratings (ekW) 400 350 455 410 365 320 Integral FTDW001/2 9 9 10 11 10 10 11 12 Sub-Base FTDW0010/11 18 19 21 23 20 20 23 25 Sub-Base FTDW005 27 29 31 35 30 31 34 37 Sub-Base FTDW006 51 53 58 65 56 57 63 69 C18 Tank Design Feature Code Standby Ratings (ekW) 600 Prime Ratings (ekW) 550 545 500 Integral FTDW003/4 9 9 9 10 Sub-Base FTDW0010/11 15 17 17 18 Sub-Base FTDW005 23.5 25 25 27 Sub-Base FTDW007 51 54 54 59 Tanks with full electrical stub-up area include removable end channel. Tanks with RH/LH stub-up include stub-up area directly below the circuit breaker or power terminal strips. Dimensions include weather-protective enclosure exhaust system. Dual wall sub-base tanks are UL listed and constructed in accordance with Underwriters Laboratories Standard UL142 “Steel Aboveground Tanks for Flammable and Combustible Liquids” and Canada ULC S601 “Shop Fabricated Steel Aboveground Tanks for Flammable and Combustible Liquids.” Fuel tanks comply with the following United States NFPA Codes: NFPA 30 – Flammable and Combustible Liquids Code NFPA 37 – Standard for Installation and Use of Stationary Combustible Engine NFPA 110 – Standard for Emergency and Standby Power Systems Fuel tanks comply with the following Canadian Codes: CSA C282-09 – Emergency Electrical Power Supply for Buildings CSA B139-09 – Installation Code for Oil-Burning Equipment www.Cat-ElectricPower.com © 2014 Caterpillar All rights reserved. Materials and specifications are subject to change without notice. The International System of Units (SI) is used in this publication. LEHE0467-01 (07/14) CAT, CATERPILLAR, their respective logos, “Caterpillar Yellow,” the “Power Edge” trade dress, as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission.