Technichal Description AS-Interface Z Plug Article No. AI001 Content 1. 2. 3. 4. General............................................................................................................... 1 Block Diagram..................................................................................................... 2 Use of the Z Plug................................................................................................. 2 Technical Data.................................................................................................... 4 4.1 AS-Interface................................................................................................... 4 4.2 M12 pin out................................................................................................... 4 4.3 LED Display.................................................................................................... 4 4.4 Mechanical and Environmental Data................................................................. 5 5. Standards........................................................................................................... 5 1. General The AS-Interface Z Plug AI001 is a passive component of the fieldbus system ASInterface without an own address. It serves as network extension utility for networks with up to 200m length without repeaters. Previously only 100m network lengths were possible. The AS-Interface Z Plug AI001 can furthermore be used as indicator for undervoltage detection. If the AS-Interface supply voltage is within the specified level the green indicator LED will light up. If the supply voltage drops below the lower limit of the specified voltage range it will start flashing. Rev. 6, 27.02.2006 Page 1 of 5 ICS Industrial Communication Solutions GmbH D-88069 Tettnang Germany All rights reserved. Changes without prior notice Technical Description AS-Interface Z Plug Article No. AI001 2. Block Diagram Block Diagram of the AS-Interface Z Plug 3. Use of the Z Plug The AS-Interface Z Plug AI001 can be utilised to extend AS-Interface networks beyond the limit of 100m. With it's help it is possible to double network length to up to 200m without repeaters. In standard networks, where signal quality is below average due to full load or use of non standard network cable it may be possible to reduce telegram error rates with the insertion of the Z Plug. Furthermore the Z Plug has an integrated undervoltage detection circuit that signals a voltage within the specification via a green LED. A voltage below the lower specification limit is signalled via the green LED flashing. Use to extend network length If the AS-Interface Z Plug AI001 is to be used to extend network length, the following installation rule has to be observed: • The Z Plug is to be installed at the point in the network that has the longest distance to the AS-Interface power supply unit. It is not necessary to hit this point exactly, a deviation of ±10m is tolerable. Only one Z Plug per network shall be installed. Page 2 of 5 Rev. 6, 27.02.2006 ICS Industrial Communication Solutions GmbH D-88069 Tettnang Germany All rights reserved. Changes without prior notice Technichal Description AS-Interface Z Plug Article No. AI001 If repeaters are used, one Z Plug per network segment is needed, if it is longer than 100m. Due to longer signal delay times in networks with more than 100m length it is not possible to install two repeaters in series. The possibility to extend AS-Interface networks as described above also exists for networks where AS-Interface Safety at Work products are installed. The properties of AS-Interface networks without and with Z Plug are summarised in the following table: criterion without Z Plug with Z Plug 62 62 max. number of slaves possible network structures star, ring, line, line with taps, tree max. distance Master-Slave without (with) repeaters max. distance Slave-Slave without (with) repeaters star, ring, line, line with taps, tree 100m (300m with two repeaters in series) 200m (400m with one repeater) 100m (500m) 200m (600m) use for AS-Interface signal quality improvement If in networks with up to 100m length the telegram error rate is higher than tolerable and if this high telegram error rate is due to a high load of the network and/or a non standard cable in use then the installation of a Z Plug may improve the network communication significantly. This is also true for networks where Safety at Work products are connected. The same installation rules as above apply. use for undervoltage detection At the most distant point in the network the probability is highest that the voltage drop along the line is such that the supply voltage level drops below the lower specified limit. This is particularly the case in networks with a length of up to 200m. The ASInterface Z Plug AI001, therefore, is equipped with an undervoltage detection circuit that signals a supply voltage below the specified limit with a flashing green LED. The detection circuit is designed in such a way that even short undervoltage drops (e.g. in case a high power actuator changes it's state) are detected and displayed clearly. Rev. 6, 27.02.2006 Page 3 of 5 ICS Industrial Communication Solutions GmbH D-88069 Tettnang Germany All rights reserved. Changes without prior notice Technical Description AS-Interface Z Plug Article No. AI001 4. Technical Data 4.1 AS-Interface AS-Interface Profile: reverse voltage protection: Display "Power": Display "Fault": AS-Interface operating voltage range: AS-Interface undervoltage: max. current consumption: power on delay time: AS-Interface Specification: AS-Interface IC AS-Interface certificate: --yes LED (green) --26,5...31,6 V (LED green steady state) approx. 15V...26,5V (LED green flashes) ≤ 10 mA <1s V3.0 --will be applied for 4.2 M12 pin out Pin 1: Pin 3: A+ A- For the installation of the Z-Plug on the AS-Interface flat cable an accessory flat cable connector (ICS Art. No. ZS006) is available. 4.3 LED Display supply voltage AS-Interface Display "AS-Interface voltage ok" LED green steady state Display "AS-Interface voltage below lower limit" LED green flashes with approx. 1Hz change over voltage at RT: 25,8V ±0,5V change over voltage within the operating temperature range: 25,8V ±1V Minimum duration of an undervoltage dip: 1ms Page 4 of 5 Rev. 6, 27.02.2006 ICS Industrial Communication Solutions GmbH D-88069 Tettnang Germany All rights reserved. Changes without prior notice Technichal Description AS-Interface Z Plug Minimum off-time of the LED: Article No. AI001 300ms 4.4 Mechanical and Environmental Data ambient operating temperature range: protection rating: max. vibration level (temporarily): max. shock: -25 ... 70 °C IP67 1,5mm Amplitude (10..55Hz) 10g LED All dimensions in mm M12 plug according to type JM (IEC 61076-2-101) 5. Standards IEC 62026-2:2000 This product is designed and manufactured for industrial applications and is not suitable for sale to the general public. Rev. 6, 27.02.2006 Page 5 of 5 ICS Industrial Communication Solutions GmbH D-88069 Tettnang Germany All rights reserved. Changes without prior notice