COUPLING DECOUPLING NETWORKS FOR IEC / EN 61000-4-6 IEC / EN 61000-4-6 specifies the design and performance of a range of coupling / decoupling networks (CDNs). Each CDN is specific to the type of cable and the intended signal carried on the cable. Teseq offers an extensive range of CDNs which fully comply with the requirements of the standard and provide a simple and reliable method of injecting RF energy into the equipment under test (EUT). Each CDN is also useable for emission testing, special types are meet the requirements of CISPR 15, CISPR 16-1-2, CISPR 22, CISPR 32, CISPR 35, NAMUR NE 21 and IEC / EN 61326‑3‑2. CISPR 15* CDN method CISPR 16-1-2* / 22* / 32*: 150 kHz to 30 MHz Draft CISPR 35*, noise test: 150 kHz to 30 MHz Namur and IEC / EN 61326-3-2: 10 kHz to 80 MHz IEC / EN 61000-4-6: 150 kHz to 80 (230) MHz 0.01 0.1 1 0.15 10 100 Frequency in MHz Emissions testing, Immunity testing, Extended range * Standard contains additional requirements for the CDN. IEC / EN 61000-4-6: Rules for selecting the injection method Yes Are Are CDNs CDNs applicable? suitable? No Can the requirements be met ? Screened cable? Use CDN injection No Yes Use CDN Use CDN S types Sxxx-types Yes Are cable Are the the cable screened? sceened? No Can the Is EM clamp or current requirements clamp injection applicable? be met ? Yes No Use CDN Use CDN M types Mxxx-types Yes Are Are the the cable cable power power supply supply lines? lines? Use Usedirect injection Sxxx Check the following requirements I. 150 Ω AE impedance II. Test setup can meet Figure 5 III. AE sufficiently immune No Use CDN Use CDN T types Txxx-types Yes lines Are the lines balanced? Yes Can Can the requirements requirements be met? No be met ? No Use CDN Use CDN A types Axxx-types Yes Are lines Are the the lines multi-wire multi-wire non-balanced? Use clamp or Use EM clamp or current current Injection injection subclause 7.3 Use EM clamp or Use clamp or current injection current with monitoring Injection probe and current subclause 7.4 limitation 300 230 Cable type CDN type Application Product range M type Used for unscreened AC or DC power supply M1 for one line, M2 for two lines, M2/3 switchable for two applications. or three lines, M3 for three lines, M4 for lines and M5 for five lines "-10 types" for frequency range 10 kHz to 80 MHz, "-3L and -3LN types" for connections without PE "-750V, -760V, -1000V types" for higher EUT voltages AF type Used for all unscreened, unbalanced lines, carry- Types with 4 mm banana sockets: ing low current. AF2 for two lines, AF3 for three lines, AF4 for lines, AF5 for five lines, AF7 for 7 lines and AF8 for 8 lines Types with D-Sub connector: AF8 for 8 lines, AF12 for 12 lines and AF15 for 15 lines "-10 types" for frequency range 10 kHz to 80 MHz CAN bus type Specially designed to test the unscreened CAN Types with D-Sub connector for unscreened four or five bus. lines "-10 types" for frequency range 10 kHz to 80 MHz S type Used for screened cables. Types with D-Sub connector for screened lines with up to 25 lines: "-10 types" for frequency range 10 kHz to 80 MHz Type with DIN connector S type coaxial Used for coaxial cables. Types with coaxial connector: See also product range Impedance Stabilization Networks for ISN S501A, S502A, S751 and S752. S type for USB and HDMI Specially designed to test the USB and HDMI CDN USB/c, USB/p, CDN USB3.0, CDN HDMI ST type Used for testing screened, balanced lines for CDN ST08A telecommunication ports on ITE equipment. See also product range Impedance Stabilization Networks for ISN ST08. T type Used for unscreened, balanced lines for tele- CDN T2-10, T210A...T246AS, T4-10, T411A...T4AS communication ports on ITE equipment. CDN T8, T8-10 See also product range Impedance Stabilization Networks for ISN T2A, T4A, ISN T8 and ISN T8-CAT6. 2 CDN selection chart by Teseq® May 2016 CDN M1-10 CDN M132 CDN M210B AE Port CDN M1-10 EUT Port AE Port CDN M132 EUT Port AE Port CDN M210B EUT Port AE Port 10 A CDN M216 CDN M216 EUT Port AE Port CDN M 1 4 mm safety banana 80 MHz 1 PE line sockets 150 kHz to CDN M 1 4 mm safety banana 230 (300) MHz 1 PE line sockets 150 kHz to CDN M2 AE: IEC 60320 C14 230 (300) MHz 2 power lines (L+N or DC+ / DC-) EUT: CEE 7 / 17 Emission testing CISPR 22 / 32 (ISN / AAN) Emission testing CISPR 15 (CDN method) Immunity testing 10 kHz to 80 MHz Immunity testing IEC / EN 61000-4-6 3 dB bandwidth (sinusoidal) 10 kHz to 1 Max. RF voltage V sockets Max. EUT voltage in V AC* [DC]* 4 mm safety banana 1 PE line Max. EUT current in A (50 / 60 Hz) CDN M 1 230 (300) MHz CDN case size EUT / AE connector type 150 kHz to Number of lines CDN M116 EUT Port CDN type and application Frequency range Drawing Product CDN M116 1 16 — 20 — (1) 1 1 16 — 20 — — 20 — 250 30 — 30 — 30 — 30 — 30 — 30 — 30 — 30 — 30 — 30 — 30 — (0.3) 1 1 32 (1) 1 2 10 (433) [800] 150 kHz to CDN M2 4 mm safety banana 230 (300) MHz 2 power lines (L+N or DC+ / DC-) sockets 1 2 16 250 (433) [800] CDN M216-10 CDN M216-10 EUT Port AE Port 10 kHz to CDN M2 4 mm safety banana 80 MHz 2 power lines (L+N or DC+ / DC-) sockets 1 2 16 250 (433) [800] CDN M2161000V CDN M216-1000V EUT Port AE Port 150 kHz to CDN M2 4 mm safety banana 230 (300) MHz 2 power lines (L+N or DC+ / DC-) sockets 1 2 16 500 (1000) [2000] CDN M232 CDN M232 EUT Port AE Port 150 kHz to CDN M2 4 mm safety banana 230 MHz 2 power lines (L+N or DC+ / DC-) sockets 4 2 32 300 (520) [600] CDN M232-10 CDN M232-10 EUT Port AE Port 10 kHz to CDN M2 4 mm safety banana 80 MHz 2 power lines (L+N or DC+ / DC-) sockets 4 2 32 300 (520) [600] CDN M2321000V CDN M232-1000V EUT Port AE Port 150 kHz to CDN M2 4 mm safety banana 230 MHz 2 power lines (L+N or DC+ / DC-) sockets 4 2 32 500 (1000) new in 2016 new in 2016 new in 2016 [2000] CDN M232760V-10 CDN M232-760V-10 EUT Port AE Port 10 kHz to CDN M2 4 mm safety banana 80 MHz 2 power lines (L+N or DC+ / DC-) sockets 4 2 32 500 (760) [1000] CDN M2-100 CDN M2-100750V CDN M016 CDN M2-100 EUT Port AE Port CDN M2-100-750V EUT Port AE Port CDN M016 EUT Port AE Port 150 kHz to CDN M2 Terminal block, wire 80 MHz 2 power lines (L+N or DC+ / DC-) cross section max. 5 2 (520) 25 mm2 [600] CDN M2 Terminal block, wire 80 MHz 2 power lines (L+N or DC+ / DC-) cross section max. (750) 25 mm2 [1000] CDN M2 / 3 switchable 2 / 3 4 mm safety banana 230 (300) MHz power lines (L+N or L+N+PE) sockets 2 1 2 / 3 100 300 150 kHz to 150 kHz to 5 100 16 750 250 (433) [800] *) Line to ground voltage, in round brackets line to line AC voltage, in square brackets line to line DC voltage CDN selection chart by Teseq® May 2016 3 1 Emission testing CISPR 22 / 32 (ISN / AAN) Emission testing CISPR 15 (CDN method) Immunity testing 10 kHz to 80 MHz Immunity testing IEC / EN 61000-4-6 3 10 CDN M316 EUT Port AE Port 250 30 — 30 — 30 — 30 — 30 — 30 — 30 — 30 — 30 — 30 — 30 — 30 — 30 — 30 — (433) 10 A CDN M316 3 dB bandwidth (sinusoidal) EUT: Schuko CEE 7 / 4 Max. RF voltage V AE: IEC 60320 C14 3 power lines (L+N+PE) Max. EUT current in A (50 / 60 Hz) CDN M3 230 (300) MHz CDN case size EUT / AE connector type 150 kHz to Max. EUT voltage in V AC* [DC]* AE Port Number of lines CDN M310B EUT Port CDN type and application Frequency range Drawing Product CDN M310B [800] 150 kHz to CDN M3 4 mm safety banana 230 (300) MHz 3 power lines (L+N+PE) sockets 1 3 16 250 (433) [800] CDN M316-10 CDN M316-10 EUT Port AE Port 10 kHz to CDN M3 4 mm safety banana 80 MHz 3 power lines (L+N+PE) sockets 1 3 16 250 (433) [800] CDN M3161000V CDN M316-1000V EUT Port AE Port 150 kHz to CDN M3 4 mm safety banana 230 MHz 3 power lines (L+N+PE) sockets 1 3 16 500 (1000) [2000] CDN M316-3L CDN M316-3L EUT Port AE Port 150 kHz to CDN M3 4 mm safety banana 230 (300) MHz 3 power lines (3L) sockets 1 3 16 250 (433) [800] CDN M3163L-10 CDN M316-3L-10 EUT Port AE Port 10 kHz to CDN M3 4 mm safety banana 80 MHz 3 power lines (3L) sockets 1 3 16 250 (433) [800] CDN M316B CDN M316B EUT Port AE Port 16 A CDN M332 CDN M332 EUT Port AE Port 150 kHz to CDN M3 AE: IEC 60320 C20 230 (300) MHz 3 power lines (L+N+PE) EUT: 4 mm safety (433) banana sockets [800] 150 kHz to CDN M3 4 mm safety banana 230 MHz 3 power lines (L+N+PE) sockets 1 4 3 3 16 32 250 300 (520) [600] CDN M332-10 CDN M332-10 EUT Port AE Port 10 kHz to CDN M3 4 mm safety banana 80 MHz 3 power lines (L+N+PE) sockets 4 3 32 300 (520) [600] CDN M3321000V CDN M332-1000V EUT Port AE Port 150 kHz to CDN M3 4 mm safety banana 80 MHz 3 power lines (L+N+PE) sockets 4 3 32 500 (1000) new in 2016 [2000] CDN M332760V-10 CDN M332-760V-10 EUT Port AE Port 10 kHz to CDN M3 4 mm safety banana 80 MHz 3 power lines (L+N+PE) sockets 4 3 32 500 (760) [1000] CDN M332-3L CDN M332-3L EUT Port AE Port 150 kHz to CDN M3 4 mm safety banana 230 MHz 3 power lines (3L) sockets 4 3 32 300 (520) [600] CDN M332-3L1000V CDN M332-3L-1000V EUT Port AE Port 150 kHz to CDN M3 4 mm safety banana 80 MHz 3 power lines (3L) sockets 4 3 32 500 (1000) new in 2016 [2000] CDN M332-3L760V-10 CDN M332-3L-760V-10 EUT Port AE Port 10 kHz to CDN M3 4 mm safety banana 80 MHz 3 power lines (3L) sockets 4 3 32 500 (760) [1000] 4 CDN selection chart by Teseq® May 2016 CDN M416A CDN M3-100-3L EUT Port AE Port CDN M3-100-750V EUT Port AE Port CDN M3-100-3L-750V EUT Port AE Port CDN M416A EUT Port AE Port Number of lines Max. EUT current in A (50 / 60 Hz) Emission testing CISPR 22 / 32 (ISN / AAN) Emission testing CISPR 15 (CDN method) Immunity testing 10 kHz to 80 MHz Immunity testing IEC / EN 61000-4-6 EUT / AE connector type CDN type and application CDN case size 5 3 100 3 dB bandwidth (sinusoidal) CDN M3-1003L-750V AE Port Max. RF voltage V CDN M3-100750V CDN M3-100 EUT Port Max. EUT voltage in V AC* [DC]* CDN M3-1003L Frequency range Drawing Product new in 2016 new in 2016 new in 2016 new in 2016 CDN M3-100 300 30 — 30 — 30 — 30 — 30 — 30 — 30 — 30 — 30 — 30 — 30 — 30 — 30 — 30 — 150 kHz to CDN M3 Terminal block, wire 80 MHz 3 power lines (L+N+PE) cross section max. (520) 25 mm2 [600] 150 kHz to CDN M3 Terminal block, wire 80 MHz 3 power lines (3L) cross section max. 5 (520) 25 mm2 [600] 5 3 CDN M3 Terminal block, wire 80 MHz 3 power lines (L+N+PE) cross section max. (750) 25 mm2 [1000] CDN M3 Terminal block, wire 80 MHz 3 power lines (3L) cross section max. (750) 25 mm2 [1000] CDN M4 4 mm safety banana 230 MHz 4 power lines (3L+PE) sockets 1 4 100 750 150 kHz to 150 kHz to 3 100 300 150 kHz to 5 3 100 16 750 300 (520) [600] CDN M416A3LN CDN M416A-3LN EUT Port AE Port 150 kHz to CDN M4 4 mm safety banana 230 MHz 4 power lines (3L+N) sockets 1 4 16 300 (520) [600] CDN M432 CDN M432 EUT Port AE Port 150 kHz to CDN M4 4 mm safety banana 230 MHz 4 power lines (3L+PE) sockets 4 4 32 300 (520) [600] CDN M432-10 CDN M432-10 EUT Port AE Port 10 kHz to CDN M4 4 mm safety banana 80 MHz 4 power lines (3L+PE) sockets 4 4 32 300 (520) [600] CDN M4321000V CDN M432-1000V EUT Port AE Port 150 kHz to CDN M4 4 mm safety banana 80 MHz 4 power lines (3L+PE) sockets 4 4 32 500 (1000) new in 2016 [2000] CDN M432760V-10 CDN M432-760V-10 EUT Port AE Port 10 kHz to CDN M4 4 mm safety banana 80 MHz 4 power lines (3L+PE) sockets 4 4 32 500 (760) [1000] CDN M432-3LN CDN M432-3LN EUT Port AE Port 150 kHz to CDN M4 4 mm safety banana 230 MHz 4 power lines (3L+N) sockets 4 4 32 300 (520) [600] CDN M4323LN-10 CDN M432-3LN-10 EUT Port AE Port 10 kHz to CDN M4 4 mm safety banana 80 MHz 4 power lines (3L+N) sockets 4 4 32 300 (520) [600] CDN M4323LN-1000V CDN M432-3LN-1000V EUT Port AE Port 150 kHz to CDN M4 4 mm safety banana 80 MHz 4 power lines (3L+N) sockets 4 4 32 500 (1000) new in 2016 [2000] CDN M4323LN-760V-10 CDN M432-3LN-760V-10 EUT Port AE Port 10 kHz to CDN M4 4 mm safety banana 80 MHz 4 power lines (3L+N) sockets 4 4 32 500 (760) [1000] CDN selection chart by Teseq® May 2016 5 CDN M516A CDN M4-100-3LN EUT Port AE Port CDN M4-100-750V EUT Port AE Port CDN M4-100-3LN-750V EUT Port AE Port CDN M516A EUT Port AE Port Number of lines Max. EUT current in A (50 / 60 Hz) Emission testing CISPR 22 / 32 (ISN / AAN) Emission testing CISPR 15 (CDN method) Immunity testing 10 kHz to 80 MHz Immunity testing IEC / EN 61000-4-6 EUT / AE connector type CDN type and application CDN case size 5 4 100 3 dB bandwidth (sinusoidal) CDN M4-1003LN-750V AE Port Max. RF voltage V CDN M4-100750V CDN M4-100 EUT Port Max. EUT voltage in V AC* [DC]* CDN M4-1003LN Frequency range Drawing Product new in 2016 new in 2016 new in 2016 new in 2016 CDN M4-100 300 30 — 30 — 30 — 30 — 30 — 30 — 30 — 30 — 30 — 30 — 30 — 150 kHz to CDN M4 Terminal block, wire 80 MHz 4 power lines (3L+PE) cross section max. (520) 25 mm2 [600] 150 kHz to CDN M4 Terminal block, wire 80 MHz 4 power lines (3L+N) cross section max. 5 (520) 25 mm2 [600] 5 4 CDN M4 Terminal block, wire 80 MHz 4 power lines (3L+PE) cross section max. (750) 25 mm2 [1000] CDN M4 Terminal block, wire 80 MHz 4 power lines (3L+N) cross section max. (750) 25 mm2 [1000] CDN M5 4 mm safety banana 230 MHz 5 power lines (3L+N+PE) sockets 1 5 100 750 150 kHz to 150 kHz to 4 100 300 150 kHz to 5 4 100 16 750 300 (520) [600] CDN M532 CDN M532 EUT Port AE Port 150 kHz to CDN M5 4 mm safety banana 230 MHz 5 power lines (3L+N+PE) sockets 4 5 32 300 (520) [600] CDN M532-10 CDN M532-10 EUT Port AE Port 10 kHz to CDN M5 4 mm safety banana 80 MHz 5 power lines (3L+N+PE) sockets 4 5 32 300 (520) [600] CDN M532-1000V CDN M532-1000V EUT Port AE Port 150 kHz to CDN M5 4 mm safety banana 80 MHz 5 power lines (3L+N+PE) sockets 4 5 32 500 (1000) new in 2016 new in 2016 new in 2016 [2000] CDN M532-760V-10 CDN M532-760V-10 EUT Port 10 kHz to CDN M5 4 mm safety banana 80 MHz 5 power lines (3L+N+PE) sockets 4 5 32 500 (760) [1000] CDN M5-100 CDN M5-100750V CDN A201A CDN M5-100 EUT Port CDN A201A50V AE Port CDN M5-100-750V EUT Port AE Port CDN A201A EUT Port new in 2016 AE Port AE Port CDN A201A-50V EUT Port AE Port 150 kHz to CDN M5 Terminal block, wire 80 MHz 5 power lines (3L+N+PE) cross section max. 5 (520) 25 mm2 [600] CDN M5 Terminal block, wire 5 power lines (3L+N+PE) cross section max. (750) 25 mm2 [1000] CDN AF2 for unscreened unbal- 4 mm safety banana anced 2 lines application sockets 150 kHz to CDN AF2 for unscreened unbal- 4 mm safety banana 230 (300) MHz anced 2 lines application, no sockets 1 2 100 300 80 MHz 230 (300) MHz 5 100 150 kHz to 150 kHz to 5 5 4 750 250 30 [300] 1 2 4 50 20 kHz 30 [50] 20 kHz resistors against ground CDN A201A-10 CDN A201A-10 EUT Port AE Port 10 kHz to CDN AF2 for unscreened unbal- 4 mm safety banana 80 MHz anced 2 lines application sockets 6 CDN selection chart by Teseq® May 2016 1 2 4 250 [300] 30 20 kHz new in 2016 CDN A301A-50V EUT Port AE Port 150 kHz to CDN AF3 for unscreened unbal- 4 mm safety banana 230 (300) MHz anced 3 lines application, no sockets 1 4 250 30 [300] 1 3 4 50 3 dB bandwidth (sinusoidal) Emission testing CISPR 22 / 32 (ISN / AAN) Emission testing CISPR 15 (CDN method) Immunity testing 10 kHz to 80 MHz Immunity testing IEC / EN 61000-4-6 3 Max. RF voltage V sockets Max. EUT voltage in V AC* [DC]* 4 mm safety banana anced 3 lines application Max. EUT current in A (50 / 60 Hz) CDN AF3 for unscreened unbal- 230 (300) MHz CDN case size EUT / AE connector type CDN type and application 150 kHz to 20 kHz 30 [50] 20 kHz resistors against ground CDN A301A10 CDN A401A CDN A301A-10 EUT Port CDN A401A50V AE Port CDN A401A EUT Port new in 2016 AE Port Number of lines CDN A301A EUT Port CDN A301A50V Frequency range Drawing Product CDN A301A AE Port CDN A401A-50V EUT Port AE Port 10 kHz to CDN AF3 for unscreened unbal- 4 mm safety banana 80 MHz anced 3 lines application sockets 150 kHz to CDN AF4 for unscreened unbal- 4 mm safety banana 230 (300) MHz anced 4 lines application sockets 150 kHz to CDN AF4 for unscreened unbal- 4 mm safety banana 230 (300) MHz anced 4 lines application, no sockets 1 3 4 250 30 [300] 1 4 4 250 30 [300] 1 4 4 50 20 kHz 20 kHz 30 [50] 20 kHz resistors against ground CDN A401A-10 CDN A401A-10 EUT Port CDN A501 CDN A501 EUT Port CDN A501-10 CDN A801 AE Port CDN A801 AE Port CDN A801-10 EUT Port CDN A120 AE Port CDN A800-10 EUT Port EUT Port CDN A801-10 AE Port CDN A800 EUT Port CDN A80010 AE Port CDN A701 EUT Port CDN A800 AE Port CDN A501-10 EUT Port CDN A701 AE Port AE Port CDN A120 EUT Port AE Port 10 kHz to CDN AF4 for unscreened unbal- 4 mm safety banana 80 MHz anced 4 lines application sockets 150 kHz to CDN AF5 for unscreened unbal- 4 mm safety banana 230 (300) MHz anced 5 lines application sockets 10 kHz to CDN AF5 for unscreened unbal- 4 mm safety banana 80 MHz anced 5 lines application sockets 150 kHz to CDN AF7 for unscreened unbal- 4 mm banana sockets 230 (300) MHz anced 7 lines application 150 kHz to CDN AF8 for unscreened unbal- 230 (300) MHz anced 8 lines application 10 kHz to CDN AF8 for unscreened unbal- 80 MHz anced 8 lines application 150 kHz to CDN AF8 for unscreened unbal- 230 (300) MHz anced 8 lines application 10 kHz to CDN AF8 for unscreened unbal- 80 MHz anced 8 lines application 150 kHz to CDN AF12 for unscreened un- 230 (300) MHz balanced 12 lines application 1 4 4 250 30 [300] 1 5 4 160 30 [250] 1 5 4 160 7 2 160 30 1 8 0.2 63 30 1 8 0.2 63 15 1 8 2 160 15 1 8 2 160 30 1 12 0.2 63 [100] 20 kHz 15 [100] 25 pin D-sub female 20 kHz [100] 25 pin D-sub female 20 kHz [100] 4 mm banana sockets 20 kHz [100] 25 pin D-sub female 20 kHz [250] 25 pin D-sub female 20 kHz [250] 1 20 kHz 20 kHz 15 20 kHz CDN selection chart by Teseq® May 2016 7 CDN CANU4-10 CDN CANU5 CDN S501A CDN CAN EUT Port new in 2016 CDN S900-10 CDN S900m AE Port AE Port AE Port Audio 'XLR' AE Port miniatur socket 5-Pole (DIN) AE Port AE Port CDN S900m EUT Port with 4 lines 150 kHz to CDN for unscreened CAN bus 230 MHz with 5 lines 150 kHz to CDN S1 for coaxial line 50 Ω 63 15 [100] 9 pin D-sub female 1 4 3 / 0.5 48 1 4 3 / 0.5 48 20 1 5 3 / 0.5 48 20 1 1 0.25 250 30 MHz 20 [48] BNC 50 Ω, female 30 MHz [48] 9 pin D-sub female 20 kHz [48] 9 pin D-sub female 3 dB bandwidth (sinusoidal) Emission testing CISPR 22 / 32 (ISN / AAN) Emission testing CISPR 15 (CDN method) Immunity testing 10 kHz to 80 MHz Immunity testing IEC / EN 61000-4-6 CDN case size 0.2 Max. RF voltage V CDN for unscreened CAN bus 80 MHz 15 Max. EUT voltage in V AC* [DC]* 10 kHz to Max. EUT current in A (50 / 60 Hz) with 4 lines EUT / AE connector type CDN type and application CDN for unscreened CAN bus 230 MHz 1 30 MHz 20 230 MHz 2 GHz 10 kHz to CDN S1 for coaxial line 50 Ω BNC 50 Ω, female 1 1 0.25 250 20 80 MHz 2 GHz 150 kHz to CDN S1 for coaxial line 50 Ω, 230 MHz double screened 150 kHz to CDN S1 for coaxial line 75 Ω N 50 Ω, female 1 1 0.25 250 20 2 GHz BNC 75 Ω, female 1 1 0.25 250 20 230 MHz 2 GHz 150 kHz to CDN S1 for coaxial line 75 Ω, 230 MHz double screened 150 kHz to CDN S2 for 2 wires, screened 230 MHz line 150 kHz to CDN S4 for 4 wires, screened 230 MHz line 150 kHz to CDN S9 for 9 wires, screened 230 MHz line 10 kHz to CDN S9 for 9 wires, screened 80 MHz line 150 kHz to CDN S9 for 9 wires, screened 230 MHz line N 75 Ω, female 3 1 0.25 250 20 2 GHz N, 75 Ω CDN S900-10 EUT Port 150 kHz to 25 pin D-sub female BNC, 75 Ω CDN S900 EUT Port balanced 15 lines application N, 50 Ω CDN S400 EUT Port miniatur socket 5-Pole (DIN) CDN S900 AE Port CDN S200 EUT Port CDN AF15 for unscreened un- 230 (300) MHz BNC, 50 Ω CDN S752A EUT Port Audio 'XLR' CDN S400 AE Port CDN S751A EUT Port 150 kHz to BNC, 50 Ω CDN S502A EUT Port N, 75 Ω CDN S200 AE Port CDN S501-10 EUT Port BNC, 75 Ω CDN S752A AE Port CDN S501A EUT Port N, 50 Ω CDN S751A AE Port CDN CAN EUT Port BNC, 50 Ω CDN S502A AE Port CDN CAN EUT Port BNC, 50 Ω CDN S501-10 AE Port Number of lines CDN A150 EUT Port CDN CANU4 Frequency range Drawing Product CDN A150 AE Port 8 CDN selection chart by Teseq® May 2016 XLR, female 1 2 0.25 150 20 20 kHz 5 pin DIN socket 1 4 0.25 34 20 20 kHz 9 pin D-sub female 1 9 0.25 150 20 20 kHz 9 pin D-sub female 1 9 0.25 150 20 20 kHz 9 pin D-sub male 1 9 0.25 150 20 20 kHz CDN S250 CDN S250-10 CDN ST08A CDN S250 EUT Port AE Port CDN S250-10 EUT Port AE Port CDN ST08A EUT Port AE Port RJ45 RJ45 line 150 kHz to CDN S25 for 25 wires, screened 230 MHz line 10 kHz to CDN S25 for 25 wires, screened 80 MHz line 150 kHz to CDN for screened and balanced 230 MHz telecommunication lines, Ether- 1 15 0.25 150 20 3 dB bandwidth (sinusoidal) Emission testing CISPR 22 / 32 (ISN / AAN) Emission testing CISPR 15 (CDN method) Immunity testing 10 kHz to 80 MHz Immunity testing IEC / EN 61000-4-6 CDN case size EUT / AE connector type 15 pin D-sub female Max. RF voltage V CDN S15 for 15 wires, screened 230 MHz Max. EUT voltage in V AC* [DC]* 150 kHz to Max. EUT current in A (50 / 60 Hz) AE Port Number of lines CDN S150 EUT Port CDN type and application Frequency range Drawing Product CDN S150 20 kHz 25 pin D-sub female 1 25 0.25 150 20 20 kHz 25 pin D-sub female 1 25 0.25 150 20 20 kHz RJ45 socket 1 8 1 100 20 250 MHz net 10BaseT, 100BaseT, 1000BaseT, 10GBaseT and others CDN ST08-10 CDN ST08-10 EUT Port AE Port RJ45 RJ45 10 kHz to CDN for screened and balanced 80 MHz telecommunication lines, Ether- RJ45 socket 1 8 1 100 20 250 MHz net 10BaseT, 100BaseT, 1000BaseT, 10GBaseT and others CDN USB/C CDN USB/c EUT Port USB (B-type) CDN USB/C-10 CDN USB/P USB (B-type) CDN USB3.0 USB (A-type) AE Port AE Port EUT: USB "B"type 10 kHz to CDN USB for central devices, AE: USB "A"type 80 MHz USB up to 2.0 EUT: USB "B"type 150 kHz to CDN USB for peripheral devices, AE: USB "B"type 230 MHz USB up to 2.0 EUT: USB "A"type 10 kHz to CDN USB for peripheral devices, AE: USB "B"type 80 MHz USB up to 2.0 EUT: USB "A"type 150 kHz to CDN USB, up to 3.0 AE: USB "A"type 1 4 1 100 20 80 MHz 1 4 1 100 20 80 MHz 1 4 1 100 20 80 MHz 1 4 1 100 20 80 MHz USB (B-type) AE Port 230 MHz 1 9 1 100 20 - HDMI socket 3 19 - 100 20 - 1 mm banana sockets 2 2 0.4 63 20 EUT: USB "A"type USB (A-type) CDN HDMI EUT Port AE: USB "A"type USB up to 2.0 USB (B-type) CDN USB3.0 EUT Port CDN USB for central devices, 230 MHz USB (A-type) CDN USB/P-10 EUT Port USB (A-type) CDN HDMI AE Port CDN USB/p EUT Port 150 kHz to USB (A-type) CDN USB/C-10 EUT Port USB (A-type) CDN USB/P-10 AE Port AE Port 150 kHz to CDN for high speed HDMI with 230 MHz HDCP, HEC (Ethernet), ARC and DSC CDN T2-10 CDN T2-10 EUT Port CDN T210A CDN T200A EUT Port CDN T240A AE Port AE Port CDN T200A EUT Port AE Port 10 kHz to T2 for 1 unscreened balanced 300 MHz wire pair 150 kHz to T2 for 1 unscreened balanced 25 pin D-sub female 80 MHz wire pair, pin arrangement with adapter to RJ11: customer specific ADR T210 150 kHz to T2 for 1 unscreened balanced 25 pin D-sub female 80 MHz wire pair, pin arrangement with adapter to RJ45: customer specific ADR T240 100 MHz 2 2 0.4 63 15 100 MHz 2 2 0.4 63 15 100 MHz CDN selection chart by Teseq® May 2016 9 CDN T4-10 AE Port CDN T4-10 EUT Port CDN T410A AE Port CDN T400A EUT Port CDN T411A AE Port CDN T400A EUT Port CDN T440A AE Port CDN T400A EUT Port CDN T442A AE Port CDN T400A EUT Port CDN T443A AE Port CDN T400A EUT Port CDN T444A AE Port CDN T400A EUT Port CDN T445A AE Port CDN T400A EUT Port AE Port Siemens, UP0 ADR T246 10 kHz to T4 for 2 unscreened balanced 1 mm banana sockets 300 MHz wire pairs 150 kHz to T4 for up to 2 unscreened bal- 25 pin D-sub female 80 MHz anced wire pairs, pin arrange- with adapter to RJ11: ment customer specific ADR T410 150 kHz to T4 for up to 2 unscreened 25 pin D-sub female 80 MHz balanced wire pairs, German with adapter to RJ11: Telecom, US standard ADR T411 150 kHz to T4 for up to 2 unscreened bal- 25 pin D-sub female 80 MHz anced wire pairs, pin arrange- with adapter to RJ45: ment customer specific ADR T440 150 kHz to T4 for up to 2 unscreened 25 pin D-sub female 80 MHz balanced wire pairs, ISDN basic with adapter to RJ45: rate access S0 ADR T442 150 kHz to T4 for up to 2 unscreened bal- 25 pin D-sub female 80 MHz anced wire pairs, ISDN primary with adapter to RJ45: rate access (2Mbps) ADR T443 150 kHz to T4 for up to 2 unscreened bal- 25 pin D-sub female 80 MHz anced wire pairs, Ethernet with adapter to RJ45: 10BaseT, 100BaseT ADR T444 150 kHz to T4 for up to 2 unscreened bal- 25 pin D-sub female 80 MHz anced wire pairs, ATM, FDDI with adapter to RJ45: 2 0.4 63 15 3 dB bandwidth (sinusoidal) Emission testing CISPR 22 / 32 (ISN / AAN) Emission testing CISPR 15 (CDN method) Immunity testing 10 kHz to 80 MHz 2 Max. RF voltage V with adapter to RJ45: Max. EUT voltage in V AC* [DC]* 25 pin D-sub female wire pair, German Telecom, Max. EUT current in A (50 / 60 Hz) T2 for 1 unscreened balanced 80 MHz Immunity testing IEC / EN 61000-4-6 CDN case size EUT / AE connector type 150 kHz to Number of lines CDN T200A EUT Port CDN type and application Frequency range Drawing Product CDN T246A 100 MHz 2 4 0.4 63 20 100 MHz 2 2 0.4 63 15 4 2 2 0.4 63 15 4 2 0.4 63 15 4 0.4 63 15 4 0.4 63 15 4 100 MHz 2 0.4 63 15 4 2 100 MHz 2 2 100 MHz 2 2 100 MHz 2 2 100 MHz 100 MHz 2 0.4 63 15 4 100 MHz ADR T445 CDN T4A CDN T400A EUT Port AE Port 150 kHz to T4 for up to 2 unscreened bal- 25 pin D-sub female 80 MHz anced wire pairs with 5 adapter with adapter to RJxx: sets ADR T411, T442, T443, 2 2 0.4 63 15 4 100 MHz T444, T445 CDN T8-10 CDN T8-10 CDN T8 EUT Port AE Port RJ45 RJ45 CDN T800 EUT Port AE Port 10 kHz to T8 for 4 unscreened balanced 230 MHz wire pairs, Ethernet 1000BaseT RJ45 socket 2 8 150 kHz to T8 for up to 4 unscreened bal- 25 pin D-sub female 80 MHz anced wire pairs with 2 adapter with adapter to RJxx: 4 sets, Ethernet 10BaseT, 100Ba- ADR T811, T800 6 0.4 63 15 100 MHz 2 2 seT, 1000BaseT and others 0.4 63 15 100 MHz 8 CDN case size L2 CDN H AE Port EUT Port L1 10 CDN selection chart by Teseq® May 2016 CDN dimensions in mm CDN case size 1 e.g. CDN M016 CDN case size 2 e.g. CDN T CDN case size 3 e.g. CDN HDMI CDN case size 4 e.g. CDN Mx 32A CDN case size 5 e.g. CDN Mx 100A Length L1 240 110 285 470 470 Length L2 180 102 235 420 420 Width 100 105 100 160 200 Height 100 55 100 160 200 COUPLING DECOUPLING NETWORK FOR EMISSION MEASUREMENT (CDNE) CISPR 16-2-1’s most recent edition 3.0 specifies a new test method which allows the use of a coupling / decoupling network for emission measurement (CDNE) to measure disturbance voltages in the 30 to 300 MHz frequency range. This method enables EUTs to be connected directly to the CDNE, allowing a single conducted emission measurement to replace a lengthy radiated emission test. Product standards may use this fast, convenient and economical alternative. CISPR 15 offers an independent method for measurement of radio disturbance characteristics of electrical lighting equipment. This method specifies the use of a coupling / decoupling network (CDN) as defined in IEC 61000-4-6 with an extended frequency range 30 to 300 MHz. Using a CDNE as described in CISPR 16-1-2 instead of CDN offers improved measurement reproducibility due to standard’s requirements for more restrictive limits of asymmetrical impedance, phase angle, symmetrical impedance and internal attenuation. CDNE M310 CDNE M310 EUT Port CDNE M310USJP AE Port AE Port 30 MHz to 30 MHz to EUT Port 300 MHz 10 M3, L, N, PE 4 mm safety banana AE: IEC C14 EUT: NEMA 5-15 20 (520) - 3 10 sockets M3, L, N, PE 300 Internal attenuator 2 Transducer factor in dB Emission testing draft CISPR 16-1-2 Emission testing CISPR 15 Immunity testing - Max. EUT voltage in V for AC* 4 mm safety banana sockets 300 MHz CDNE M310-USJP AE Port M2, L, N or DC 300 MHz Max. EUT current in A 30 MHz to Number of lines CDNE M210 EUT Port EUT / AE connector type Frequency range Drawing CDNE M210 CDN type and application The Teseq CDNEs are compliant with the actual versions of CSIPR 16-1-2, CISPR 16-2-1 and CISPR 15’s CDN method. 300 20 (520) - 3 10 125 20 (125) *) Line to ground voltage, in brackets line to line voltage CDN selection chart by Teseq® May 2016 11 IMPEDANCE STABILIZATION NETWORK (ISN), ASYMMETRIC ARTIFICIAL NETWORK (AAN) Impedance stabilization networks (ISN, or with CISPR 16-1-2 called AAN: asymmetric artificial network) are defined for measuring of conducted common mode disturbances at information technology equipment (ITE) as required in CISPR 22 and CISPR 32. The ISN is placed between the equipment under test (EUT) and auxiliary equipment (AE) or load which are necessary for the operation of the EUT. The ISN establishes the common-mode termination impedance for the EUT’s telecommunications port during measurement and emulates the unsymmetrical contribution (longitudinal conversion loss, LCL) of the connected line. Different ISNs are available in relation to the line category, line numbers and pin-arrangement. The ISN must not affect the normal quality of the wanted symmetrical signal. The CISPR 16-1-2 gives additional requirements and provides examples and measurements for the networks. The ITU-T recommendations G.117 and O.9 offers the background knowledge for measurements on symmetrical telecommunication lines. Further the ISNs (with exception ISN T8) can be used as coupling / decoupling network as defined in IEC / EN 61000-4-6 „Immunity to conducted disturbances, induced by radio frequency fields”. Cable type Number of pairs Refers to figure in CISPR 32 Measurement type Product Balanced unscreened 1 (2 wire) 2 (4 wire) 3 (6 wire) 4 (8 wire) Figure G.1 to Figure G.3 Figure G.2 to Figure G.3 Figure G.3 Figure G.3 Voltage ISN T Balanced unscreened >4 Voltage and current CVP, CSP Screened or coaxial n / a Voltage ISN S ISN ST Screened or coaxial n / a Voltage or current CVP, CSP Unbalanced n / a Voltage and current CVP, CSP AC Mains n / a Voltage NNB 12 CDN selection chart by Teseq® May 2016 Figure G.9 for coaxial Figure G11 for multiconductor AMN CISPR 16-1-2:2003 Figure 4 and Figure 5 ISN T216A AE Port ISN T200A EUT Port AE Port 150 kHz to T2 for 1 unscreened balanced pair, RJ11 30 (80) MHz UP0 with RJ11, with adapter 0.6 65 / 50 G.2 2 55 / 40 63 / 15 100 0.6 65 / 50 63 / 3 dB bandwidth (sinusoidal) Changeable adapter wiring Emission testing CISPR 22 / 32 55 / 40 Max. RF voltage in V 1 mm 2 Max. EUT voltage in V for AC / DC T2X0 G.2 Max. EUT current in A (per wire) RJ45 LCL values RJ11 with adapter ADS T246 and ADS Number of lines T2 for 1 unscreened balanced pair 30 (80) MHz Immunity testing IEC / EN 61000-4-6 EUT / AE connector type 150 kHz to Regarding figure in CISPR 32 ISN T200A EUT Port CDN type and application Frequency range Drawing ISN T2A 100 MHz 15 100 100 MHz ADS T216 ISN T246A ISN T200A EUT Port AE Port 150 kHz to T2 for 1 unscreened balanced pair, 30 (80) MHz UP0 with RJ45, with adapter ADS RJ45 G.2 2 55 / 40 0.6 65 / 50 63 / 15 100 100 MHz T246 ISN T4A ISN T400A EUT Port ISN T411A AE Port ISN T400A EUT Port AE Port 150 kHz to T4 for up to 2 unscreened bal- RJ11 30 (80) MHz anced pairs, with adapter ADS RJ45 T411, T442, T443, T444 and T4x0 1 mm 150 kHz to T4 for up to 2 unscreened bal- RJ11 30 (80) MHz anced pairs, German Telecom, US G.2 G.2 2 55 / 40 4 65 / 50 2 55 / 40 4 65 / 50 2 55 / 40 4 65 / 50 2 55 / 40 4 65 / 50 2 55 / 40 4 65 / 50 2 55 / 40 4 65 / 50 0.6 63 / 15 100 0.6 63 / 100 MHz 15 100 100 MHz standard, with adapter ADS T411 ISN T442A ISN T400A EUT Port AE Port 150 kHz to T4 for up to 2 unscreened bal- 30 (80) MHz anced pairs, ISDN basic rate access RJ45 G.2 0.6 63 / 15 100 100 MHz S0, with adapter ADS T442 ISN T443A ISN T400A EUT Port AE Port 150 kHz to T4 for up to 2 unscreened bal- 30 (80) MHz anced pairs, ISDN primary rate RJ45 G.2 0.6 63 / 15 100 100 MHz access (2Mbps), with ADS T443 ISN T444A ISN T400A EUT Port AE Port 150 kHz to T4 for up to 2 unscreened bal- 30 (80) MHz anced pairs, Ethernet 10BaseT, RJ45 G.2 0.6 63 / 15 100 100 MHz 100BaseT, with adapter ADS T444 ISN T4X0A ISN T400A EUT Port ISN T8 AE Port ISN T800 EUT Port AE Port 150 kHz to T4 for up to 2 unscreened bal- RJ11 30 (80) MHz anced pairs, with changeable RJ45 G.2 adapter ADS T4X0 1 mm 150 kHz to T8 for up to 4 unscreened bal- RJ11 2 55 / 40 30 MHz anced pairs, Ethernet 10BaseT, RJ45 4 65 / 50 100BaseT, 1000 BaseT and others, 1 mm 6 G.3 with adapter ADS T800 and T8X0 ISN T8-Cat6 ISN T8-Cat6 EUT Port AE Port 0.6 63 / 15 100 0.6 100 MHz 63 / 100 100 MHz 8 150 kHz to T8 for up to 4 unscreened bal- 30 (80) MHz anced pairs, Ethernet 10BaseT, RJ45 G.3 2 4 100BaseT, 1000 BaseT and others 6 75 / 60 0.6 63 / 100 15 250 MHz 8 FIX ISN: Option for ISN T series The magnetic fixture for ISNs (Impedance Stabilization Network) improves the earth connection to steel surfaces as typical used for Faraday cages. Its design provides a constant and stable pressure of the ISN enclosure against the ground plane. The standard CISPR 22/ 32 allows to place the ISNs also to a vertical ground plane which can be done easily with the use of FIX ISN. CDN selection chart by Teseq® May 2016 13 AE Port RJ45 RJ45 telecommunication lines, Ethernet RJ45 1.2 100 20 3 dB bandwidth (sinusoidal) LCL values Changeable adapter wiring Number of lines Emission testing CISPR 22 / 32 Immunity testing IEC / EN 61000-4-6 Regarding figure in CISPR 32 G.11 8 Max. RF voltage in V For screened and balanced 230 MHz Max. EUT voltage in V for AC / DC 150 kHz to Max. EUT current in A (per wire) ISN ST08 EUT Port EUT / AE connector type CDN type and application Frequency range Drawing ISN ST08 250 MHz 10BaseT, 100BaseT, 1000BaseT, 10GBaseT and others ISN S501A ISN S501A EUT Port BNC, 50 Ω ISN S502A N, 50 Ω BNC, 75 Ω ISN S752 AE Port AE Port N, 75 Ω lines with 50 Ω 150 kHz to For coaxial telecommunication 230 MHz lines with 50 Ω, double screened 150 kHz to For coaxial telecommunication 230 MHz lines with 75 Ω 150 kHz to For coaxial telecommunication 230 MHz lines with 75 Ω, double screened BNC G.9 1 0.25 250 20 2 GHz N G.9 1 0.25 250 20 2 GHz BNC G.9 1 0.25 250 20 2 GHz N G.9 1 0.25 250 20 2 GHz BNC, 75 Ω ISN S752 EUT Port For coaxial telecommunication 230 MHz N, 50 Ω ISN S751 EUT Port 150 kHz to BNC, 50 Ω ISN S502A EUT Port ISN S751 AE Port AE Port N, 75 Ω Teseq GmbH Landsberger Str. 255 · 12623 Berlin · Germany T + 49 30 56 59 88 35 F + 49 30 56 59 88 34 deinfo.teseq@ametek.com www.teseq.com © May 2016 Teseq ® Specifications subject to change without notice. Teseq ® is an ISO-registered company. Its products are designed and manufactured under the strict quality and environmental requirements of the ISO 9001. This document has been carefully checked. However, Teseq® does not assume any liability for errors or inaccuracies. CDN selection chart by Teseq® May 2016