COUPLING DECOUPLING NETWORKS FOR IEC / EN 61000-4-6

advertisement
COUPLING DECOUPLING NETWORKS
FOR IEC / EN 61000-4-6
IEC / EN 61000-4-6 specifies the design and performance of a range of coupling / decoupling
networks (CDNs). Each CDN is specific to the type of cable and the intended signal carried on
the cable. Teseq offers an extensive range of CDNs which fully comply with the requirements
of the standard and provide a simple and reliable method of injecting RF energy into the
equipment under test (EUT). Each CDN is also useable for emission testing, special types are
meet the requirements of CISPR 15, CISPR 16-1-2, CISPR 22, CISPR 32, CISPR 35, NAMUR NE
21 and IEC / EN 61326‑3‑2.
CISPR 15*
CDN method
CISPR 16-1-2* / 22* / 32*: 150 kHz to 30 MHz
Draft CISPR 35*, noise test: 150 kHz to 30 MHz
Namur and IEC / EN 61326-3-2: 10 kHz to 80 MHz
IEC / EN 61000-4-6: 150 kHz to 80 (230) MHz
0.01
0.1
1
0.15
10
100
Frequency in MHz
Emissions testing,
Immunity testing, Extended range
* Standard contains additional requirements for the CDN.
IEC / EN 61000-4-6: Rules for selecting the injection method
Yes
Are
Are CDNs
CDNs
applicable?
suitable?
No
Can the
requirements
be met ?
Screened cable?
Use CDN injection
No
Yes
Use CDN
Use
CDN
S types
Sxxx-types
Yes
Are
cable
Are the
the cable
screened?
sceened?
No
Can the
Is EM clamp
or current
requirements
clamp injection
applicable?
be met ?
Yes
No
Use CDN
Use
CDN
M types
Mxxx-types
Yes
Are
Are the
the cable
cable
power
power supply
supply lines?
lines?
Use
Usedirect
injection
Sxxx
Check the following
requirements
I. 150 Ω AE impedance
II. Test setup can meet Figure 5
III. AE sufficiently immune
No
Use CDN
Use
CDN
T types
Txxx-types
Yes
lines
Are the lines
balanced?
Yes
Can
Can the
requirements
requirements
be met?
No
be met ?
No
Use CDN
Use
CDN
A types
Axxx-types
Yes
Are
lines
Are the
the lines
multi-wire
multi-wire
non-balanced?
Use clamp or
Use EM clamp or
current
current
Injection
injection
subclause 7.3
Use EM clamp or
Use clamp or
current injection
current
with monitoring
Injection
probe and current
subclause 7.4
limitation
300
230
Cable type
CDN type
Application
Product range
M type
Used for unscreened AC or DC power supply
M1 for one line, M2 for two lines, M2/3 switchable for two
applications.
or three lines, M3 for three lines, M4 for lines and M5 for
five lines
"-10 types" for frequency range 10 kHz to 80 MHz,
"-3L and -3LN types" for connections without PE
"-750V, -760V, -1000V types" for higher EUT voltages
AF type
Used for all unscreened, unbalanced lines, carry-
Types with 4 mm banana sockets:
ing low current.
AF2 for two lines, AF3 for three lines, AF4 for lines, AF5 for
five lines, AF7 for 7 lines and AF8 for 8 lines
Types with D-Sub connector:
AF8 for 8 lines, AF12 for 12 lines and AF15 for 15 lines
"-10 types" for frequency range 10 kHz to 80 MHz
CAN bus type
Specially designed to test the unscreened CAN
Types with D-Sub connector for unscreened four or five
bus.
lines
"-10 types" for frequency range 10 kHz to 80 MHz
S type
Used for screened cables.
Types with D-Sub connector for screened lines with up to
25 lines:
"-10 types" for frequency range 10 kHz to 80 MHz
Type with DIN connector
S type coaxial
Used for coaxial cables.
Types with coaxial connector:
See also product range Impedance Stabilization Networks
for ISN S501A, S502A, S751 and S752.
S type for USB and
HDMI
Specially designed to test the USB and HDMI
CDN USB/c, USB/p, CDN USB3.0, CDN HDMI
ST type
Used for testing screened, balanced lines for
CDN ST08A
telecommunication ports on ITE equipment.
See also product range Impedance Stabilization Networks
for ISN ST08.
T type
Used for unscreened, balanced lines for tele-
CDN T2-10, T210A...T246AS, T4-10, T411A...T4AS
communication ports on ITE equipment.
CDN T8, T8-10
See also product range Impedance Stabilization Networks
for ISN T2A, T4A, ISN T8 and ISN T8-CAT6.
2 CDN selection chart by Teseq® May 2016
CDN M1-10
CDN M132
CDN M210B
AE Port
CDN M1-10
EUT Port
AE Port
CDN M132
EUT Port
AE Port
CDN M210B
EUT Port
AE Port
10 A
CDN M216
CDN M216
EUT Port
AE Port
CDN M 1
4 mm safety banana
80 MHz
1 PE line
sockets
150 kHz to
CDN M 1
4 mm safety banana
230 (300) MHz
1 PE line
sockets
150 kHz to
CDN M2
AE: IEC 60320 C14
230 (300) MHz
2 power lines (L+N or DC+ / DC-)
EUT: CEE 7 / 17
Emission testing CISPR 22 / 32 (ISN / AAN)
Emission testing CISPR 15 (CDN method)
Immunity testing 10 kHz to 80 MHz
Immunity testing IEC / EN 61000-4-6
3 dB bandwidth (sinusoidal)
10 kHz to
1
Max. RF voltage V
sockets
Max. EUT voltage in V AC* [DC]*
4 mm safety banana
1 PE line
Max. EUT current in A (50 / 60 Hz)
CDN M 1
230 (300) MHz
CDN case size
EUT / AE connector type
150 kHz to
Number of lines
CDN M116
EUT Port
CDN type and application
Frequency range
Drawing
Product
CDN M116
1
16
—
20
—
(1)
1
1
16
—
20
—
—
20
—
250
30
—
30
—
30
—
30
—
30
—
30
—
30
—
30
—
30
—
30
—
30
—
(0.3)
1
1
32
(1)
1
2
10
(433)
[800]
150 kHz to
CDN M2
4 mm safety banana
230 (300) MHz
2 power lines (L+N or DC+ / DC-)
sockets
1
2
16
250
(433)
[800]
CDN M216-10
CDN M216-10
EUT Port
AE Port
10 kHz to
CDN M2
4 mm safety banana
80 MHz
2 power lines (L+N or DC+ / DC-)
sockets
1
2
16
250
(433)
[800]
CDN M2161000V
CDN M216-1000V
EUT Port
AE Port
150 kHz to
CDN M2
4 mm safety banana
230 (300) MHz
2 power lines (L+N or DC+ / DC-)
sockets
1
2
16
500
(1000)
[2000]
CDN M232
CDN M232
EUT Port
AE Port
150 kHz to
CDN M2
4 mm safety banana
230 MHz
2 power lines (L+N or DC+ / DC-)
sockets
4
2
32
300
(520)
[600]
CDN M232-10
CDN M232-10
EUT Port
AE Port
10 kHz to
CDN M2
4 mm safety banana
80 MHz
2 power lines (L+N or DC+ / DC-)
sockets
4
2
32
300
(520)
[600]
CDN M2321000V
CDN M232-1000V
EUT Port
AE Port
150 kHz to
CDN M2
4 mm safety banana
230 MHz
2 power lines (L+N or DC+ / DC-)
sockets
4
2
32
500
(1000)
new in 2016 new in 2016 new in 2016
[2000]
CDN M232760V-10
CDN M232-760V-10
EUT Port
AE Port
10 kHz to
CDN M2
4 mm safety banana
80 MHz
2 power lines (L+N or DC+ / DC-)
sockets
4
2
32
500
(760)
[1000]
CDN M2-100
CDN M2-100750V
CDN M016
CDN M2-100
EUT Port
AE Port
CDN M2-100-750V
EUT Port
AE Port
CDN M016
EUT Port
AE Port
150 kHz to
CDN M2
Terminal block, wire
80 MHz
2 power lines (L+N or DC+ / DC-)
cross section max.
5
2
(520)
25 mm2
[600]
CDN M2
Terminal block, wire
80 MHz
2 power lines (L+N or DC+ / DC-)
cross section max.
(750)
25 mm2
[1000]
CDN M2 / 3 switchable 2 / 3
4 mm safety banana
230 (300) MHz
power lines (L+N or L+N+PE)
sockets
2
1
2 / 3
100
300
150 kHz to
150 kHz to
5
100
16
750
250
(433)
[800]
*) Line to ground voltage, in round brackets line to line AC voltage, in square brackets line to line DC voltage
CDN selection chart by Teseq® May 2016 3
1
Emission testing CISPR 22 / 32 (ISN / AAN)
Emission testing CISPR 15 (CDN method)
Immunity testing 10 kHz to 80 MHz
Immunity testing IEC / EN 61000-4-6
3
10
CDN M316
EUT Port
AE Port
250
30
—
30
—
30
—
30
—
30
—
30
—
30
—
30
—
30
—
30
—
30
—
30
—
30
—
30
—
(433)
10 A
CDN M316
3 dB bandwidth (sinusoidal)
EUT: Schuko CEE 7 / 4
Max. RF voltage V
AE: IEC 60320 C14
3 power lines (L+N+PE)
Max. EUT current in A (50 / 60 Hz)
CDN M3
230 (300) MHz
CDN case size
EUT / AE connector type
150 kHz to
Max. EUT voltage in V AC* [DC]*
AE Port
Number of lines
CDN M310B
EUT Port
CDN type and application
Frequency range
Drawing
Product
CDN M310B
[800]
150 kHz to
CDN M3
4 mm safety banana
230 (300) MHz
3 power lines (L+N+PE)
sockets
1
3
16
250
(433)
[800]
CDN M316-10
CDN M316-10
EUT Port
AE Port
10 kHz to
CDN M3
4 mm safety banana
80 MHz
3 power lines (L+N+PE)
sockets
1
3
16
250
(433)
[800]
CDN M3161000V
CDN M316-1000V
EUT Port
AE Port
150 kHz to
CDN M3
4 mm safety banana
230 MHz
3 power lines (L+N+PE)
sockets
1
3
16
500
(1000)
[2000]
CDN M316-3L
CDN M316-3L
EUT Port
AE Port
150 kHz to
CDN M3
4 mm safety banana
230 (300) MHz
3 power lines (3L)
sockets
1
3
16
250
(433)
[800]
CDN M3163L-10
CDN M316-3L-10
EUT Port
AE Port
10 kHz to
CDN M3
4 mm safety banana
80 MHz
3 power lines (3L)
sockets
1
3
16
250
(433)
[800]
CDN M316B
CDN M316B
EUT Port
AE Port
16 A
CDN M332
CDN M332
EUT Port
AE Port
150 kHz to
CDN M3
AE: IEC 60320 C20
230 (300) MHz
3 power lines (L+N+PE)
EUT: 4 mm safety
(433)
banana sockets
[800]
150 kHz to
CDN M3
4 mm safety banana
230 MHz
3 power lines (L+N+PE)
sockets
1
4
3
3
16
32
250
300
(520)
[600]
CDN M332-10
CDN M332-10
EUT Port
AE Port
10 kHz to
CDN M3
4 mm safety banana
80 MHz
3 power lines (L+N+PE)
sockets
4
3
32
300
(520)
[600]
CDN M3321000V
CDN M332-1000V
EUT Port
AE Port
150 kHz to
CDN M3
4 mm safety banana
80 MHz
3 power lines (L+N+PE)
sockets
4
3
32
500
(1000)
new in 2016
[2000]
CDN M332760V-10
CDN M332-760V-10
EUT Port
AE Port
10 kHz to
CDN M3
4 mm safety banana
80 MHz
3 power lines (L+N+PE)
sockets
4
3
32
500
(760)
[1000]
CDN M332-3L
CDN M332-3L
EUT Port
AE Port
150 kHz to
CDN M3
4 mm safety banana
230 MHz
3 power lines (3L)
sockets
4
3
32
300
(520)
[600]
CDN M332-3L1000V
CDN M332-3L-1000V
EUT Port
AE Port
150 kHz to
CDN M3
4 mm safety banana
80 MHz
3 power lines (3L)
sockets
4
3
32
500
(1000)
new in 2016
[2000]
CDN M332-3L760V-10
CDN M332-3L-760V-10
EUT Port
AE Port
10 kHz to
CDN M3
4 mm safety banana
80 MHz
3 power lines (3L)
sockets
4
3
32
500
(760)
[1000]
4 CDN selection chart by Teseq® May 2016
CDN M416A
CDN M3-100-3L
EUT Port
AE Port
CDN M3-100-750V
EUT Port
AE Port
CDN M3-100-3L-750V
EUT Port
AE Port
CDN M416A
EUT Port
AE Port
Number of lines
Max. EUT current in A (50 / 60 Hz)
Emission testing CISPR 22 / 32 (ISN / AAN)
Emission testing CISPR 15 (CDN method)
Immunity testing 10 kHz to 80 MHz
Immunity testing IEC / EN 61000-4-6
EUT / AE connector type
CDN type and application
CDN case size
5
3
100
3 dB bandwidth (sinusoidal)
CDN M3-1003L-750V
AE Port
Max. RF voltage V
CDN M3-100750V
CDN M3-100
EUT Port
Max. EUT voltage in V AC* [DC]*
CDN M3-1003L
Frequency range
Drawing
Product
new in 2016 new in 2016 new in 2016 new in 2016
CDN M3-100
300
30
—
30
—
30
—
30
—
30
—
30
—
30
—
30
—
30
—
30
—
30
—
30
—
30
—
30
—
150 kHz to
CDN M3
Terminal block, wire
80 MHz
3 power lines (L+N+PE)
cross section max.
(520)
25 mm2
[600]
150 kHz to
CDN M3
Terminal block, wire
80 MHz
3 power lines (3L)
cross section max.
5
(520)
25 mm2
[600]
5
3
CDN M3
Terminal block, wire
80 MHz
3 power lines (L+N+PE)
cross section max.
(750)
25 mm2
[1000]
CDN M3
Terminal block, wire
80 MHz
3 power lines (3L)
cross section max.
(750)
25 mm2
[1000]
CDN M4
4 mm safety banana
230 MHz
4 power lines (3L+PE)
sockets
1
4
100
750
150 kHz to
150 kHz to
3
100
300
150 kHz to
5
3
100
16
750
300
(520)
[600]
CDN M416A3LN
CDN M416A-3LN
EUT Port
AE Port
150 kHz to
CDN M4
4 mm safety banana
230 MHz
4 power lines (3L+N)
sockets
1
4
16
300
(520)
[600]
CDN M432
CDN M432
EUT Port
AE Port
150 kHz to
CDN M4
4 mm safety banana
230 MHz
4 power lines (3L+PE)
sockets
4
4
32
300
(520)
[600]
CDN M432-10
CDN M432-10
EUT Port
AE Port
10 kHz to
CDN M4
4 mm safety banana
80 MHz
4 power lines (3L+PE)
sockets
4
4
32
300
(520)
[600]
CDN M4321000V
CDN M432-1000V
EUT Port
AE Port
150 kHz to
CDN M4
4 mm safety banana
80 MHz
4 power lines (3L+PE)
sockets
4
4
32
500
(1000)
new in 2016
[2000]
CDN M432760V-10
CDN M432-760V-10
EUT Port
AE Port
10 kHz to
CDN M4
4 mm safety banana
80 MHz 4 power lines (3L+PE)
sockets
4
4
32
500
(760)
[1000]
CDN M432-3LN
CDN M432-3LN
EUT Port
AE Port
150 kHz to
CDN M4
4 mm safety banana
230 MHz 4 power lines (3L+N)
sockets
4
4
32
300
(520)
[600]
CDN M4323LN-10
CDN M432-3LN-10
EUT Port
AE Port
10 kHz to
CDN M4
4 mm safety banana
80 MHz
4 power lines (3L+N)
sockets
4
4
32
300
(520)
[600]
CDN M4323LN-1000V
CDN M432-3LN-1000V
EUT Port
AE Port
150 kHz to
CDN M4
4 mm safety banana
80 MHz
4 power lines (3L+N)
sockets
4
4
32
500
(1000)
new in 2016
[2000]
CDN M4323LN-760V-10
CDN M432-3LN-760V-10
EUT Port
AE Port
10 kHz to
CDN M4
4 mm safety banana
80 MHz
4 power lines (3L+N)
sockets
4
4
32
500
(760)
[1000]
CDN selection chart by Teseq® May 2016 5
CDN M516A
CDN M4-100-3LN
EUT Port
AE Port
CDN M4-100-750V
EUT Port
AE Port
CDN M4-100-3LN-750V
EUT Port
AE Port
CDN M516A
EUT Port
AE Port
Number of lines
Max. EUT current in A (50 / 60 Hz)
Emission testing CISPR 22 / 32 (ISN / AAN)
Emission testing CISPR 15 (CDN method)
Immunity testing 10 kHz to 80 MHz
Immunity testing IEC / EN 61000-4-6
EUT / AE connector type
CDN type and application
CDN case size
5
4
100
3 dB bandwidth (sinusoidal)
CDN M4-1003LN-750V
AE Port
Max. RF voltage V
CDN M4-100750V
CDN M4-100
EUT Port
Max. EUT voltage in V AC* [DC]*
CDN M4-1003LN
Frequency range
Drawing
Product
new in 2016 new in 2016 new in 2016 new in 2016
CDN M4-100
300
30
—
30
—
30
—
30
—
30
—
30
—
30
—
30
—
30
—
30
—
30
—
150 kHz to
CDN M4
Terminal block, wire
80 MHz
4 power lines (3L+PE)
cross section max.
(520)
25 mm2
[600]
150 kHz to
CDN M4
Terminal block, wire
80 MHz
4 power lines (3L+N)
cross section max.
5
(520)
25 mm2
[600]
5
4
CDN M4
Terminal block, wire
80 MHz
4 power lines (3L+PE)
cross section max.
(750)
25 mm2
[1000]
CDN M4
Terminal block, wire
80 MHz
4 power lines (3L+N)
cross section max.
(750)
25 mm2
[1000]
CDN M5
4 mm safety banana
230 MHz
5 power lines (3L+N+PE)
sockets
1
5
100
750
150 kHz to
150 kHz to
4
100
300
150 kHz to
5
4
100
16
750
300
(520)
[600]
CDN M532
CDN M532
EUT Port
AE Port
150 kHz to
CDN M5
4 mm safety banana
230 MHz
5 power lines (3L+N+PE)
sockets
4
5
32
300
(520)
[600]
CDN M532-10
CDN M532-10
EUT Port
AE Port
10 kHz to
CDN M5
4 mm safety banana
80 MHz
5 power lines (3L+N+PE)
sockets
4
5
32
300
(520)
[600]
CDN
M532-1000V
CDN M532-1000V
EUT Port
AE Port
150 kHz to
CDN M5
4 mm safety banana
80 MHz
5 power lines (3L+N+PE)
sockets
4
5
32
500
(1000)
new in 2016 new in 2016 new in 2016
[2000]
CDN
M532-760V-10
CDN M532-760V-10
EUT Port
10 kHz to
CDN M5
4 mm safety banana
80 MHz
5 power lines (3L+N+PE)
sockets
4
5
32
500
(760)
[1000]
CDN M5-100
CDN M5-100750V
CDN A201A
CDN M5-100
EUT Port
CDN A201A50V
AE Port
CDN M5-100-750V
EUT Port
AE Port
CDN A201A
EUT Port
new in 2016
AE Port
AE Port
CDN A201A-50V
EUT Port
AE Port
150 kHz to
CDN M5
Terminal block, wire
80 MHz
5 power lines (3L+N+PE)
cross section max.
5
(520)
25 mm2
[600]
CDN M5
Terminal block, wire
5 power lines (3L+N+PE)
cross section max.
(750)
25 mm2
[1000]
CDN AF2 for unscreened unbal-
4 mm safety banana
anced 2 lines application
sockets
150 kHz to
CDN AF2 for unscreened unbal-
4 mm safety banana
230 (300) MHz
anced 2 lines application, no
sockets
1
2
100
300
80 MHz
230 (300) MHz
5
100
150 kHz to
150 kHz to
5
5
4
750
250
30
[300]
1
2
4
50
20
kHz
30
[50]
20
kHz
resistors against ground
CDN
A201A-10
CDN A201A-10
EUT Port
AE Port
10 kHz to
CDN AF2 for unscreened unbal-
4 mm safety banana
80 MHz
anced 2 lines application
sockets
6 CDN selection chart by Teseq® May 2016
1
2
4
250
[300]
30
20
kHz
new in 2016
CDN A301A-50V
EUT Port
AE Port
150 kHz to
CDN AF3 for unscreened unbal-
4 mm safety banana
230 (300) MHz
anced 3 lines application, no
sockets
1
4
250
30
[300]
1
3
4
50
3 dB bandwidth (sinusoidal)
Emission testing CISPR 22 / 32 (ISN / AAN)
Emission testing CISPR 15 (CDN method)
Immunity testing 10 kHz to 80 MHz
Immunity testing IEC / EN 61000-4-6
3
Max. RF voltage V
sockets
Max. EUT voltage in V AC* [DC]*
4 mm safety banana
anced 3 lines application
Max. EUT current in A (50 / 60 Hz)
CDN AF3 for unscreened unbal-
230 (300) MHz
CDN case size
EUT / AE connector type
CDN type and application
150 kHz to
20
kHz
30
[50]
20
kHz
resistors against ground
CDN A301A10
CDN A401A
CDN A301A-10
EUT Port
CDN A401A50V
AE Port
CDN A401A
EUT Port
new in 2016
AE Port
Number of lines
CDN A301A
EUT Port
CDN A301A50V
Frequency range
Drawing
Product
CDN A301A
AE Port
CDN A401A-50V
EUT Port
AE Port
10 kHz to
CDN AF3 for unscreened unbal-
4 mm safety banana
80 MHz
anced 3 lines application
sockets
150 kHz to
CDN AF4 for unscreened unbal-
4 mm safety banana
230 (300) MHz
anced 4 lines application
sockets
150 kHz to
CDN AF4 for unscreened unbal-
4 mm safety banana
230 (300) MHz
anced 4 lines application, no
sockets
1
3
4
250
30
[300]
1
4
4
250
30
[300]
1
4
4
50
20
kHz
20
kHz
30
[50]
20
kHz
resistors against ground
CDN A401A-10
CDN A401A-10
EUT Port
CDN A501
CDN A501
EUT Port
CDN A501-10
CDN A801
AE Port
CDN A801
AE Port
CDN A801-10
EUT Port
CDN A120
AE Port
CDN A800-10
EUT Port
EUT Port
CDN A801-10
AE Port
CDN A800
EUT Port
CDN A80010
AE Port
CDN A701
EUT Port
CDN A800
AE Port
CDN A501-10
EUT Port
CDN A701
AE Port
AE Port
CDN A120
EUT Port
AE Port
10 kHz to
CDN AF4 for unscreened unbal-
4 mm safety banana
80 MHz
anced 4 lines application
sockets
150 kHz to
CDN AF5 for unscreened unbal-
4 mm safety banana
230 (300) MHz
anced 5 lines application
sockets
10 kHz to
CDN AF5 for unscreened unbal-
4 mm safety banana
80 MHz
anced 5 lines application
sockets
150 kHz to
CDN AF7 for unscreened unbal-
4 mm banana sockets
230 (300) MHz
anced 7 lines application
150 kHz to
CDN AF8 for unscreened unbal-
230 (300) MHz
anced 8 lines application
10 kHz to
CDN AF8 for unscreened unbal-
80 MHz
anced 8 lines application
150 kHz to
CDN AF8 for unscreened unbal-
230 (300) MHz
anced 8 lines application
10 kHz to
CDN AF8 for unscreened unbal-
80 MHz
anced 8 lines application
150 kHz to
CDN AF12 for unscreened un-
230 (300) MHz
balanced 12 lines application
1
4
4
250
30
[300]
1
5
4
160
30
[250]
1
5
4
160
7
2
160
30
1
8
0.2
63
30
1
8
0.2
63
15
1
8
2
160
15
1
8
2
160
30
1
12
0.2
63
[100]
20
kHz
15
[100]
25 pin D-sub female
20
kHz
[100]
25 pin D-sub female
20
kHz
[100]
4 mm banana sockets
20
kHz
[100]
25 pin D-sub female
20
kHz
[250]
25 pin D-sub female
20
kHz
[250]
1
20
kHz
20
kHz
15
20
kHz
CDN selection chart by Teseq® May 2016 7
CDN CANU4-10
CDN CANU5
CDN S501A
CDN CAN
EUT Port
new in 2016
CDN S900-10
CDN S900m
AE Port
AE Port
AE Port
Audio
'XLR'
AE Port
miniatur socket
5-Pole (DIN)
AE Port
AE Port
CDN S900m
EUT Port
with 4 lines
150 kHz to
CDN for unscreened CAN bus
230 MHz
with 5 lines
150 kHz to
CDN S1 for coaxial line 50 Ω
63
15
[100]
9 pin D-sub female
1
4
3 / 0.5 48
1
4
3 / 0.5 48
20
1
5
3 / 0.5 48
20
1
1
0.25
250
30
MHz
20
[48]
BNC 50 Ω, female
30
MHz
[48]
9 pin D-sub female
20
kHz
[48]
9 pin D-sub female
3 dB bandwidth (sinusoidal)
Emission testing CISPR 22 / 32 (ISN / AAN)
Emission testing CISPR 15 (CDN method)
Immunity testing 10 kHz to 80 MHz
Immunity testing IEC / EN 61000-4-6
CDN case size
0.2
Max. RF voltage V
CDN for unscreened CAN bus
80 MHz
15
Max. EUT voltage in V AC* [DC]*
10 kHz to
Max. EUT current in A (50 / 60 Hz)
with 4 lines
EUT / AE connector type
CDN type and application
CDN for unscreened CAN bus
230 MHz
1
30
MHz
20
230 MHz
2
GHz
10 kHz to
CDN S1 for coaxial line 50 Ω
BNC 50 Ω, female
1
1
0.25
250
20
80 MHz
2
GHz
150 kHz to
CDN S1 for coaxial line 50 Ω,
230 MHz
double screened
150 kHz to
CDN S1 for coaxial line 75 Ω
N 50 Ω, female
1
1
0.25
250
20
2
GHz
BNC 75 Ω, female
1
1
0.25
250
20
230 MHz
2
GHz
150 kHz to
CDN S1 for coaxial line 75 Ω,
230 MHz
double screened
150 kHz to
CDN S2 for 2 wires, screened
230 MHz
line
150 kHz to
CDN S4 for 4 wires, screened
230 MHz
line
150 kHz to
CDN S9 for 9 wires, screened
230 MHz
line
10 kHz to
CDN S9 for 9 wires, screened
80 MHz
line
150 kHz to
CDN S9 for 9 wires, screened
230 MHz
line
N 75 Ω, female
3
1
0.25
250
20
2
GHz
N, 75 Ω
CDN S900-10
EUT Port
150 kHz to
25 pin D-sub female
BNC, 75 Ω
CDN S900
EUT Port
balanced 15 lines application
N, 50 Ω
CDN S400
EUT Port
miniatur socket
5-Pole (DIN)
CDN S900
AE Port
CDN S200
EUT Port
CDN AF15 for unscreened un-
230 (300) MHz
BNC, 50 Ω
CDN S752A
EUT Port
Audio
'XLR'
CDN S400
AE Port
CDN S751A
EUT Port
150 kHz to
BNC, 50 Ω
CDN S502A
EUT Port
N, 75 Ω
CDN S200
AE Port
CDN S501-10
EUT Port
BNC, 75 Ω
CDN S752A
AE Port
CDN S501A
EUT Port
N, 50 Ω
CDN S751A
AE Port
CDN CAN
EUT Port
BNC, 50 Ω
CDN S502A
AE Port
CDN CAN
EUT Port
BNC, 50 Ω
CDN S501-10
AE Port
Number of lines
CDN A150
EUT Port
CDN CANU4
Frequency range
Drawing
Product
CDN A150
AE Port
8 CDN selection chart by Teseq® May 2016
XLR, female
1
2
0.25
150
20
20
kHz
5 pin DIN socket
1
4
0.25
34
20
20
kHz
9 pin D-sub female
1
9
0.25
150
20
20
kHz
9 pin D-sub female
1
9
0.25
150
20
20
kHz
9 pin D-sub male
1
9
0.25
150
20
20
kHz
CDN S250
CDN S250-10
CDN ST08A
CDN S250
EUT Port
AE Port
CDN S250-10
EUT Port
AE Port
CDN ST08A
EUT Port
AE Port
RJ45
RJ45
line
150 kHz to
CDN S25 for 25 wires, screened
230 MHz
line
10 kHz to
CDN S25 for 25 wires, screened
80 MHz
line
150 kHz to
CDN for screened and balanced
230 MHz
telecommunication lines, Ether-
1
15
0.25
150
20
3 dB bandwidth (sinusoidal)
Emission testing CISPR 22 / 32 (ISN / AAN)
Emission testing CISPR 15 (CDN method)
Immunity testing 10 kHz to 80 MHz
Immunity testing IEC / EN 61000-4-6
CDN case size
EUT / AE connector type
15 pin D-sub female
Max. RF voltage V
CDN S15 for 15 wires, screened
230 MHz
Max. EUT voltage in V AC* [DC]*
150 kHz to
Max. EUT current in A (50 / 60 Hz)
AE Port
Number of lines
CDN S150
EUT Port
CDN type and application
Frequency range
Drawing
Product
CDN S150
20
kHz
25 pin D-sub female
1
25
0.25
150
20
20
kHz
25 pin D-sub female
1
25
0.25
150
20
20
kHz
RJ45 socket
1
8
1
100
20
250
MHz
net 10BaseT, 100BaseT, 1000BaseT, 10GBaseT and others
CDN ST08-10
CDN ST08-10
EUT Port
AE Port
RJ45
RJ45
10 kHz to
CDN for screened and balanced
80 MHz
telecommunication lines, Ether-
RJ45 socket
1
8
1
100
20
250
MHz
net 10BaseT, 100BaseT, 1000BaseT, 10GBaseT and others
CDN USB/C
CDN USB/c
EUT Port
USB (B-type)
CDN
USB/C-10
CDN USB/P
USB (B-type)
CDN USB3.0
USB (A-type)
AE Port
AE Port
EUT: USB "B"type
10 kHz to
CDN USB for central devices,
AE: USB "A"type
80 MHz
USB up to 2.0
EUT: USB "B"type
150 kHz to
CDN USB for peripheral devices,
AE: USB "B"type
230 MHz
USB up to 2.0
EUT: USB "A"type
10 kHz to
CDN USB for peripheral devices,
AE: USB "B"type
80 MHz
USB up to 2.0
EUT: USB "A"type
150 kHz to
CDN USB, up to 3.0
AE: USB "A"type
1
4
1
100
20
80
MHz
1
4
1
100
20
80
MHz
1
4
1
100
20
80
MHz
1
4
1
100
20
80
MHz
USB (B-type)
AE Port
230 MHz
1
9
1
100
20
-
HDMI socket
3
19
-
100
20
-
1 mm banana sockets
2
2
0.4
63
20
EUT: USB "A"type
USB (A-type)
CDN HDMI
EUT Port
AE: USB "A"type
USB up to 2.0
USB (B-type)
CDN USB3.0
EUT Port
CDN USB for central devices,
230 MHz
USB (A-type)
CDN USB/P-10
EUT Port
USB (A-type)
CDN HDMI
AE Port
CDN USB/p
EUT Port
150 kHz to
USB (A-type)
CDN USB/C-10
EUT Port
USB (A-type)
CDN
USB/P-10
AE Port
AE Port
150 kHz to
CDN for high speed HDMI with
230 MHz
HDCP, HEC (Ethernet), ARC and
DSC
CDN T2-10
CDN T2-10
EUT Port
CDN T210A
CDN T200A
EUT Port
CDN T240A
AE Port
AE Port
CDN T200A
EUT Port
AE Port
10 kHz to
T2 for 1 unscreened balanced
300 MHz
wire pair
150 kHz to
T2 for 1 unscreened balanced
25 pin D-sub female
80 MHz
wire pair, pin arrangement
with adapter to RJ11:
customer specific
ADR T210
150 kHz to
T2 for 1 unscreened balanced
25 pin D-sub female
80 MHz
wire pair, pin arrangement
with adapter to RJ45:
customer specific
ADR T240
100
MHz
2
2
0.4
63
15
100
MHz
2
2
0.4
63
15
100
MHz
CDN selection chart by Teseq® May 2016 9
CDN T4-10
AE Port
CDN T4-10
EUT Port
CDN T410A
AE Port
CDN T400A
EUT Port
CDN T411A
AE Port
CDN T400A
EUT Port
CDN T440A
AE Port
CDN T400A
EUT Port
CDN T442A
AE Port
CDN T400A
EUT Port
CDN T443A
AE Port
CDN T400A
EUT Port
CDN T444A
AE Port
CDN T400A
EUT Port
CDN T445A
AE Port
CDN T400A
EUT Port
AE Port
Siemens, UP0
ADR T246
10 kHz to
T4 for 2 unscreened balanced
1 mm banana sockets
300 MHz
wire pairs
150 kHz to
T4 for up to 2 unscreened bal-
25 pin D-sub female
80 MHz
anced wire pairs, pin arrange-
with adapter to RJ11:
ment customer specific
ADR T410
150 kHz to
T4 for up to 2 unscreened
25 pin D-sub female
80 MHz
balanced wire pairs, German
with adapter to RJ11:
Telecom, US standard
ADR T411
150 kHz to
T4 for up to 2 unscreened bal-
25 pin D-sub female
80 MHz
anced wire pairs, pin arrange-
with adapter to RJ45:
ment customer specific
ADR T440
150 kHz to
T4 for up to 2 unscreened
25 pin D-sub female
80 MHz
balanced wire pairs, ISDN basic
with adapter to RJ45:
rate access S0
ADR T442
150 kHz to
T4 for up to 2 unscreened bal-
25 pin D-sub female
80 MHz
anced wire pairs, ISDN primary
with adapter to RJ45:
rate access (2Mbps)
ADR T443
150 kHz to
T4 for up to 2 unscreened bal-
25 pin D-sub female
80 MHz
anced wire pairs, Ethernet
with adapter to RJ45:
10BaseT, 100BaseT
ADR T444
150 kHz to
T4 for up to 2 unscreened bal-
25 pin D-sub female
80 MHz
anced wire pairs, ATM, FDDI
with adapter to RJ45:
2
0.4
63
15
3 dB bandwidth (sinusoidal)
Emission testing CISPR 22 / 32 (ISN / AAN)
Emission testing CISPR 15 (CDN method)
Immunity testing 10 kHz to 80 MHz
2
Max. RF voltage V
with adapter to RJ45:
Max. EUT voltage in V AC* [DC]*
25 pin D-sub female
wire pair, German Telecom,
Max. EUT current in A (50 / 60 Hz)
T2 for 1 unscreened balanced
80 MHz Immunity testing IEC / EN 61000-4-6
CDN case size
EUT / AE connector type
150 kHz to
Number of lines
CDN T200A
EUT Port
CDN type and application
Frequency range
Drawing
Product
CDN T246A
100
MHz
2
4
0.4
63
20
100
MHz
2
2
0.4
63
15
4
2
2
0.4
63
15
4
2
0.4
63
15
4
0.4
63
15
4
0.4
63
15
4
100
MHz
2
0.4
63
15
4
2
100
MHz
2
2
100
MHz
2
2
100
MHz
2
2
100
MHz
100
MHz
2
0.4
63
15
4
100
MHz
ADR T445
CDN T4A
CDN T400A
EUT Port
AE Port
150 kHz to
T4 for up to 2 unscreened bal-
25 pin D-sub female
80 MHz anced wire pairs with 5 adapter
with adapter to RJxx:
sets
ADR T411, T442, T443,
2
2
0.4
63
15
4
100
MHz
T444, T445
CDN T8-10
CDN T8-10
CDN T8
EUT Port
AE Port
RJ45
RJ45
CDN T800
EUT Port
AE Port
10 kHz to
T8 for 4 unscreened balanced
230 MHz wire pairs, Ethernet 1000BaseT
RJ45 socket
2
8
150 kHz to
T8 for up to 4 unscreened bal-
25 pin D-sub female
80 MHz anced wire pairs with 2 adapter
with adapter to RJxx:
4
sets, Ethernet 10BaseT, 100Ba-
ADR T811, T800
6
0.4
63
15
100
MHz
2
2
seT, 1000BaseT and others
0.4
63
15
100
MHz
8
CDN case size
L2
CDN
H
AE Port
EUT Port
L1
10 CDN selection chart by Teseq® May 2016
CDN dimensions in mm
CDN case size 1
e.g. CDN M016
CDN case size 2
e.g. CDN T
CDN case size 3
e.g. CDN HDMI
CDN case size 4
e.g. CDN Mx 32A
CDN case size 5
e.g. CDN Mx 100A
Length L1
240
110
285
470
470
Length L2
180
102
235
420
420
Width
100
105
100
160
200
Height
100
55
100
160
200
COUPLING DECOUPLING NETWORK FOR
EMISSION MEASUREMENT (CDNE)
CISPR 16-2-1’s most recent edition 3.0 specifies a new test method which allows the use of
a coupling / decoupling network for emission measurement (CDNE) to measure disturbance
voltages in the 30 to 300 MHz frequency range. This method enables EUTs to be connected directly to the CDNE, allowing a single conducted emission measurement to replace a
lengthy radiated emission test. Product standards may use this fast, convenient and economical alternative.
CISPR 15 offers an independent method for measurement of radio disturbance characteristics of electrical lighting equipment. This method specifies the use of a coupling / decoupling
network (CDN) as defined in IEC 61000-4-6 with an extended frequency range 30 to 300 MHz.
Using a CDNE as described in CISPR 16-1-2 instead of CDN offers improved measurement
reproducibility due to standard’s requirements for more restrictive limits of asymmetrical
impedance, phase angle, symmetrical impedance and internal attenuation.
CDNE M310
CDNE M310
EUT Port
CDNE M310USJP
AE Port
AE Port
30 MHz to
30 MHz to
EUT Port
300 MHz
10
M3, L, N, PE
4 mm safety banana
AE: IEC C14
EUT: NEMA 5-15
20
(520)
-
3
10
sockets
M3, L, N, PE
300
Internal attenuator
2
Transducer factor in dB
Emission testing draft CISPR 16-1-2
Emission testing CISPR 15
Immunity testing
-
Max. EUT voltage in V for AC*
4 mm safety banana
sockets
300 MHz
CDNE M310-USJP
AE Port
M2, L, N or DC
300 MHz
Max. EUT current in A
30 MHz to
Number of lines
CDNE M210
EUT Port
EUT / AE connector type
Frequency range
Drawing
CDNE M210
CDN type and application
The Teseq CDNEs are compliant with the actual versions of CSIPR 16-1-2, CISPR 16-2-1 and
CISPR 15’s CDN method.
300
20
(520)
-
3
10
125
20
(125)
*) Line to ground voltage, in brackets line to line voltage
CDN selection chart by Teseq® May 2016 11
IMPEDANCE STABILIZATION NETWORK (ISN),
ASYMMETRIC ARTIFICIAL NETWORK (AAN)
Impedance stabilization networks (ISN, or with CISPR 16-1-2 called AAN: asymmetric artificial
network) are defined for measuring of conducted common mode disturbances at information technology equipment (ITE) as required in CISPR 22 and CISPR 32. The ISN is placed
between the equipment under test (EUT) and auxiliary equipment (AE) or load which are
necessary for the operation of the EUT. The ISN establishes the common-mode termination
impedance for the EUT’s telecommunications port during measurement and emulates the
unsymmetrical contribution (longitudinal conversion loss, LCL) of the connected line. Different ISNs are available in relation to the line category, line numbers and pin-arrangement. The
ISN must not affect the normal quality of the wanted symmetrical signal.
The CISPR 16-1-2 gives additional requirements and provides examples and measurements
for the networks. The ITU-T recommendations G.117 and O.9 offers the background knowledge for measurements on symmetrical telecommunication lines.
Further the ISNs (with exception ISN T8) can be used as coupling / decoupling network as
defined in IEC / EN 61000-4-6 „Immunity to conducted disturbances, induced by radio frequency fields”.
Cable type
Number of pairs
Refers to figure in CISPR 32
Measurement type
Product
Balanced
unscreened
1 (2 wire)
2 (4 wire)
3 (6 wire)
4 (8 wire)
Figure G.1 to Figure G.3
Figure G.2 to Figure G.3
Figure G.3
Figure G.3
Voltage
ISN T
Balanced
unscreened
>4
Voltage and current
CVP, CSP
Screened or
coaxial
n / a
Voltage
ISN S
ISN ST
Screened or
coaxial
n / a
Voltage or current
CVP, CSP
Unbalanced
n / a
Voltage and current
CVP, CSP
AC Mains
n / a
Voltage
NNB
12 CDN selection chart by Teseq® May 2016
Figure G.9 for coaxial
Figure G11 for multiconductor
AMN
CISPR 16-1-2:2003
Figure 4 and Figure 5
ISN T216A
AE Port
ISN T200A
EUT Port
AE Port
150 kHz to
T2 for 1 unscreened balanced pair,
RJ11
30 (80) MHz
UP0 with RJ11, with adapter
0.6
65 / 50
G.2
2
55 / 40
63 / 15
100
0.6
65 / 50
63 / 3 dB bandwidth (sinusoidal)
Changeable adapter wiring
Emission testing CISPR 22 / 32
55 / 40
Max. RF voltage in V
1 mm
2
Max. EUT voltage in V for AC / DC
T2X0
G.2
Max. EUT current in A (per wire)
RJ45
LCL values
RJ11
with adapter ADS T246 and ADS
Number of lines
T2 for 1 unscreened balanced pair
30 (80) MHz
Immunity testing IEC / EN 61000-4-6
EUT / AE connector type
150 kHz to
Regarding figure in CISPR 32
ISN T200A
EUT Port
CDN type and application
Frequency range
Drawing
ISN T2A
100
MHz
15
100
100
MHz
ADS T216
ISN T246A
ISN T200A
EUT Port
AE Port
150 kHz to
T2 for 1 unscreened balanced pair,
30 (80) MHz UP0 with RJ45, with adapter ADS
RJ45
G.2
2
55 / 40
0.6
65 / 50
63 / 15
100
100
MHz
T246
ISN T4A
ISN T400A
EUT Port
ISN T411A
AE Port
ISN T400A
EUT Port
AE Port
150 kHz to
T4 for up to 2 unscreened bal-
RJ11
30 (80) MHz
anced pairs, with adapter ADS
RJ45
T411, T442, T443, T444 and T4x0
1 mm
150 kHz to
T4 for up to 2 unscreened bal-
RJ11
30 (80) MHz
anced pairs, German Telecom, US
G.2
G.2
2
55 / 40
4
65 / 50
2
55 / 40
4
65 / 50
2
55 / 40
4
65 / 50
2
55 / 40
4
65 / 50
2
55 / 40
4
65 / 50
2
55 / 40
4
65 / 50
0.6
63 / 15
100
0.6
63 / 100
MHz
15
100
100
MHz
standard, with adapter ADS T411
ISN T442A
ISN T400A
EUT Port
AE Port
150 kHz to
T4 for up to 2 unscreened bal-
30 (80) MHz
anced pairs, ISDN basic rate access
RJ45
G.2
0.6
63 / 15
100
100
MHz
S0, with adapter ADS T442
ISN T443A
ISN T400A
EUT Port
AE Port
150 kHz to
T4 for up to 2 unscreened bal-
30 (80) MHz
anced pairs, ISDN primary rate
RJ45
G.2
0.6
63 / 15
100
100
MHz
access (2Mbps), with ADS T443
ISN T444A
ISN T400A
EUT Port
AE Port
150 kHz to
T4 for up to 2 unscreened bal-
30 (80) MHz
anced pairs, Ethernet 10BaseT,
RJ45
G.2
0.6
63 / 15
100
100
MHz
100BaseT, with adapter ADS T444
ISN T4X0A
ISN T400A
EUT Port
ISN T8
AE Port
ISN T800
EUT Port
AE Port
150 kHz to
T4 for up to 2 unscreened bal-
RJ11
30 (80) MHz
anced pairs, with changeable
RJ45
G.2
adapter ADS T4X0
1 mm
150 kHz to
T8 for up to 4 unscreened bal-
RJ11
2
55 / 40
30 MHz
anced pairs, Ethernet 10BaseT,
RJ45
4
65 / 50
100BaseT, 1000 BaseT and others,
1 mm
6
G.3
with adapter ADS T800 and T8X0
ISN T8-Cat6
ISN T8-Cat6
EUT Port
AE Port
0.6
63 / 15
100
0.6
100
MHz
63 / 100
100
MHz
8
150 kHz to
T8 for up to 4 unscreened bal-
30 (80) MHz
anced pairs, Ethernet 10BaseT,
RJ45
G.3
2
4
100BaseT, 1000 BaseT and others
6
75 / 60
0.6
63 / 100
15
250
MHz
8
FIX ISN: Option for ISN T series
The magnetic fixture for ISNs (Impedance Stabilization Network) improves the earth connection to steel surfaces as typical used for Faraday cages. Its design provides a constant and stable pressure of the ISN enclosure against the ground
plane. The standard CISPR 22/ 32 allows to place the ISNs also to a vertical ground plane which can be done easily with
the use of FIX ISN.
CDN selection chart by Teseq® May 2016 13
AE Port
RJ45
RJ45
telecommunication lines, Ethernet
RJ45
1.2
100
20
3 dB bandwidth (sinusoidal)
LCL values
Changeable adapter wiring
Number of lines
Emission testing CISPR 22 / 32
Immunity testing IEC / EN 61000-4-6
Regarding figure in CISPR 32
G.11 8
Max. RF voltage in V
For screened and balanced
230 MHz
Max. EUT voltage in V for AC / DC
150 kHz to
Max. EUT current in A (per wire)
ISN ST08
EUT Port
EUT / AE connector type
CDN type and application
Frequency range
Drawing
ISN ST08
250
MHz
10BaseT, 100BaseT, 1000BaseT,
10GBaseT and others
ISN S501A
ISN S501A
EUT Port
BNC, 50 Ω
ISN S502A
N, 50 Ω
BNC, 75 Ω
ISN S752
AE Port
AE Port
N, 75 Ω
lines with 50 Ω
150 kHz to
For coaxial telecommunication
230 MHz
lines with 50 Ω, double screened
150 kHz to
For coaxial telecommunication
230 MHz
lines with 75 Ω
150 kHz to
For coaxial telecommunication
230 MHz
lines with 75 Ω, double screened
BNC
G.9
1
0.25
250
20
2 GHz
N
G.9
1
0.25
250
20
2 GHz
BNC
G.9
1
0.25
250
20
2 GHz
N
G.9
1
0.25
250
20
2 GHz
BNC, 75 Ω
ISN S752
EUT Port
For coaxial telecommunication
230 MHz
N, 50 Ω
ISN S751
EUT Port
150 kHz to
BNC, 50 Ω
ISN S502A
EUT Port
ISN S751
AE Port
AE Port
N, 75 Ω
Teseq GmbH
Landsberger Str. 255 · 12623 Berlin · Germany
T + 49 30 56 59 88 35 F + 49 30 56 59 88 34
deinfo.teseq@ametek.com www.teseq.com
© May 2016 Teseq ®
Specifications subject to change without notice.
Teseq ® is an ISO-registered company. Its products
are designed and manufactured under the strict
quality and environmental requirements of the ISO
9001. This document has been carefully checked.
However, Teseq® does not assume any liability for
errors or inaccuracies.
CDN selection chart by Teseq® May 2016