NEW Tamper proof for Industrial Safety •Category B4 endorsement •Positively guided/mechanically linked contacts •SUVA third party certification •Front mounted auxiliary contact •Protective cover to prevent manual operation •Red contact housing for easy identification •AC and DC operated coils •Double break contacts A.B.N. 84 004 304 812 CAS 7 CSS 7 Safety Contactors Safety Control Relays Added features for contactors and relays Safety Contactors (3 pole contacts) Ratings @ 400/415 Volts Auxiliary contacts are 1 N/O, 4 N/C standard 4) AC 3 Amps 9 12 16 23 30 37 43 60 72 85 Notes: AC 3 kW 4 5.5 7.5 11 15 18.5 22 30 37 45 ) ) 3 ) 4 ) 1 2 AC Coil Cat. No. 1) 3) CAS 7-9-14C…VAC CAS 7-12-14C…VAC CAS 7-16-14C…VAC CAS 7-23-14C…VAC CAS 7-30-14C…VAC CAS 7-37-14C…VAC CAS 7-43-14C…VAC CAS 7-60-14C…VAC CAS 7-72-14C…VAC CAS 7-85-14C…VAC CAS 7 safety contactors and CSS 7 safety control relays feature mechanically linked/positively guided contacts, which are required for monitoring circuits in today’s safety applications. The inter-locking of all contacts, whether they be normally open or closed, makes it impossible for any contacts to change state if a contact becomes welded or stuck. This ensures true representation of systems operation and status. DC Coil Cat. No. 2) 3) CAS 7-9D-14C…VDC CAS 7-12D-14C…VDC CAS 7-16D-14C…VDC CAS 7-23D-14C…VDC CAS 7-30D-14C…VDC CAS 7-37D-14C…VDC CAS 7-43D-14C…VDC CAS 7-60D-14C…VDC CAS 7-72D-14C…VDC CAS 7-85D-14C…VDC 240 V 50 Hz and 110 V 50 Hz as standard. 24 V DC with integrated diode as standard. Other control voltages are available on request. Other contact configurations are available on request. • • • • • • • • • Tamper proof design Compact design Vibration resistant Reversible coil terminals Suitable for “Type 2 co-ordination” Compatible with the entire range of CA 7 / CS 7 accessories Fixed auxiliary block that is vibration resistant Protective cover to prevent manual operation Features the IEC 60947-5-1 “mechanically linked symbol” Safety relay CSS 7 with AC/DC control AC 15 Amps 230/240 V 5 5 5 5 400/415 V 2.5 2.5 2.5 2.5 AC 12 Amps 40 °C 10 10 10 10 Auxiliary contacts N/O N/C 6 2 5 3 4 4 3 5 AC Coil Cat. No. CSS 7-62EC…VAC CSS 7-53EC…VAC CSS 7-44EC…VAC CSS 7-35EC…VAC DC Coil Cat. No. CSS 7D-62EC…VDC CSS 7D-53EC…VDC CSS 7D-44EC…VDC CSS 7D-35EC…VDC Notes: Standard coil voltage 110 V 50 Hz AC, 240 V 50 Hz AC and 24 V DC. Other voltages available on request. Base unit contacts have a AC 15 rating of 10 Amps at 240 V 50 Hz. www.nhp.com.au Melbourne Sydney Newcastle Brisbane Townsville Rockhampton Toowoomba Cairns Adelaide Perth A.B.N. 84 004 304 812 Darwin Hobart PH: +61 3 9429 2999 +61 2 9748 3444 +61 2 4960 2220 +61 7 3891 6008 +61 7 4779 0700 +61 7 4927 2277 +61 7 4634 4799 +61 7 4035 6888 +61 8 8297 9055 +61 8 9277 1777 +61 8 8947 2666 +61 3 6228 9575 FAX: +61 3 9429 1075 +61 2 9648 4353 +61 2 4960 2203 +61 7 3891 6139 +61 7 4775 1457 +61 7 4922 2947 +61 7 4633 1796 +61 7 4035 6999 +61 8 8371 0962 +61 8 9277 1700 +61 8 8947 2049 +61 3 6228 9757 Version 6 FLYER CAS7-F CAS7-F 11/02 14M