BECLED Series Combination LED Exit Signs with

advertisement
JOB NAME:
TYPE NO.:
CATALOG NO.:
BECLED Series Combination LED
Exit Signs with Incandescent Heads
ORDERING INFORMATION
Catalog Number: Example: BECLED1RWKR9
MODEL
NUMBER
BECLED -Emergency
LED Combo
Unit
R
1
BECLED
NUMBER
OF FACES
1 -Single Face
LETTER
COLOR
R - Red
HOUSING
COLOR
W-White
B -Black
OPTIONS
see below
N
Housing: Exit housings are constructed of 20-gauge steel finished in baked-on
Construction powder paint providing scratch and corrosion resistance.
Lighting Heads: Impact resistant, UV stable, UL-94-5VA flame rated thermoplastic.
Heads and swivels are fully adjustable with lockable swivels.
Installation
Mounting hardware is provided and units designed for attachment to most
standard 31/2” and 4” electrical boxes in wall, ceiling or end mount applications.
Exit Face
Letter Size: 8” letters with 3/4” stroke meet NYC code. All models utilize acrylic
exit panels with screened on letters. Panels are supplied with red letters and a
choice of white or mirrored mylar backgrounds. Universal applique directional arrow chevrons meet UL visibility requirements.
Illumination
Normal AC and emergency exit face illumination is provided by a special high
intensity red LED lighting bar. Letter brightness and illumination uniformity
exceed UL requirements. Three lighting heads with 6V, 12W tungsten lamps
are provided for emergency illumination.
Electronics
• Dual input 120/277VAC, 60 Hz
• AC Lockout protection
• AC-On indicator light and test switch • Low voltage battery disconnect
• Automatic charger and transfer circuit Approv
ty
SPECIFICATIONS
York Ci
(1) Other options available.
(2) Some options may impact UL listing.
ed
ew
OPTIONS (1)(2)
KR9 6V, 9W Krypton Lamps
UL Damp
Location Listed!
PRODUCT FEATURES
• Emergency combination exit/emergency lighting units
• 20-gauge steel enclosure with scratch resistant white or
black finish
• For wall surface mounting applications
• Universal directional knockout chevrons
• High output long life LED lamps
• NYC approved 8” red exit letters
• Universal 120/277VAC field selectable input
• Supplied with three 6V, 12W tungsten lighting heads
• 90 minutes of emergency lighting
• Fully automatic, temperature compensated charger
• Long life lead calcium battery
• Automatic low voltage disconnect
• AC Lockout feature reduces installation time
• Momentary test switch and AC-On LED indicator
• UL operating range 32ºF to 104ºF (0ºC to 40ºC)
• Meets NFPA Life Safety Code 101, NEC, OSHA and
New York City requirements
• UL924 listed
• UL Listed for use in damp locations
DIMENSIONS
Power
Normal Input Power: 5W (max) Regardless of AC input voltage.
Consumption Emergency models will draw up to 15W (max.) during charge cycles.
Battery
Sealed lead calcium long life maintenance free battery.
Optimum operating temperature range: 32ºF to 104ºF (0ºC to 40ºC). Provides a minimum of 90 minutes of full output emergency illumination.
Code Compliance
All models are UL Damp Location Listed. Emergency models are UL924 listed.
Meets NFPA Life Safety Code 101, NEC, OSHA and NewYork City requirements.
Warranty
Limited 3-year warranty. 3-year sealed lead calcium pro-rata battery warranty.
6”
15.2cm
161/2”
41.9cm
101/2”
26.7cm
141/2”
Specifications are subject to change without notice. Consult website for latest version of this spec sheet.
Crescent/Stonco • 200 Franklin Square Drive • Somerset, NJ 08873 • 908-964-7000 • www.crescentlighting.com
Crescent is a Philips company
4”
36.8cm
10.1cm
NOTE: Dimensions and specifications subject to change without notice.
Form 1196A 04/12 © 2006 Philips group