codes
•
•
•
•
•
UL Listed to Standard 924
NFPA 101 (National Life Safety Code)
NEC 70 (National Electric Code)
OSHA illumination standards.
Suitable for damp, wet, dusty or dirty
environments
construction
• Corrosion resistant wet location type sealed and
gasketed enclosure.
• Unit is industrial gray polycarbonate with clear
polycarbonate cover.
• EXIT lettering is 6” lettering with ¾” stroke.
• Removable direction arrows sized to meet UL
visibility requirements.
installation
• Units are designed for installation to wall surfaces
by means of four through holes provided in the
enclosure housing.
• Knockouts are provided on both sides of the
enclosure for attachment to surface wiring or
conduit.
electronics
• Lead Calcium emergency units utilize a battery
charger that is fully automatic, temperature
compensating, and variable rate type charger.
• Nickel Cadmium emergency units utilize a battery
charger that is fully automatic, temperature
compensating, and constant current type charger.
• Surge protected with solid state circuitry.
Charging systems are complete with low voltage
battery disconnect and AC lockout
• Momentary test switch and LED AC on indicator
light.
• 120/277VAC, 60Hz.
• Power Consumption: 120V 4.8 W; 277V 4.6W.
Power Factor on all models: 0.85 lagging
• Operating Temperature Range: Nickel Cadmium
emergency unit with no remote capacity: 32°F
(0°F) to 104°F (40°C). All other models AC and
Emergency: 68°F (20°C) to 86°F (30°C).
CH-40550
• Optional Self-Diagnostic Circuit – SX option
automatically cycles the emergency lighting
unit every 25-30 days. The SX circuit checks
for battery charging and over charging, battery
capacity and reports any system malfunction. By
design the SX does not activate the lighting heads,
thus avoiding substantial lamp life reduction.
rev. 1,
Industrial Exit Signs
VNL Series
Economical Wet Location
Exit Combo
lamps
• Exit face illumination is provided by a special high
intensity indirect red or green LED panel. Letter
brightness and illumination uniformity exceed UL
requirements.
• High output incandescent lamps maximize
illumination characteristics through a specially
designed reflector and glass lens assembly that
provides glare free trapezoidal light distribution.
• Lamps are incandescent wedge base Par36 sealed
beam.
• Lamp heads are impact resistant, UV stable, flame
rated thermoplastic housings.
• Lamp heads have a matching gray finish.
• Lamp heads are sealed, gasketed, fully adjustable,
and feature lockable swivels.
battery
• Choice of 6V maintenance free sealed lead
calcium battery with a service life of 5 to 7 years.
OR
• 6V maintenance free nickel cadmium battery with
a service life of 8 to 10 years.
• Both provide a minimum of 90 minutes
emergency illumination.
Specifier’s Reference
Project
Type
Model No.
Comments
remote capacity
• Total lamp Wattage cannot exceed total fixture
wattage.
warranty
• Five full year warranty on electronics and unit
(excluding lamps).
Green Product Choice:VNL-R
–
–
Letter Color
Options
R – Red
G – Green
SX – Self-Diagnostic Circuit2
DEH – Two Side-Mounted 7.2W Lighting Heads
(VNLCL,VNLCN models only)2
IA – Audible Intermittent Alarm
(emergency models only)2
IV – Visual Intermittent Alarm
(emergency models only)2
FI – Fire Alarm Panel Interface3
TD1 – 15 Minute Retransfer Delay (120VAC)
TD2 – 15 Minute Retransfer Delay (277VAC)
TC1 – Two Circuit Input (120VAC)
TC2 – Two Circuit Input (277VAC)
Family
VNL – AC-Only Exit - 120/277VAC
input
VNLN – Exit w/Nickel Cadmium
Battery (no remote capacity)
VNLCL – Exit or combo unit w/Heavy
Duty Lead Calcium Battery
(with 24W remote capacity)
VNLCN – Exit or combo unit w/Heavy
Duty Nickel Cadmium Battery
(with 24W remote capacity)
© 2013 Koninklijke Philips Electronics N.V. All rights reserved.
Specifications are subject to change without notice.
CH-40550 03/13 Accessories (Order Separately)
1
PG-5 – Wire Guard (exits without lighting heads)
PG-10 – Wire Guard (exits with lighting heads)
Footnote
Some options may impact UL listing. Consult factory
DEX, SX, IA, IV, and FA options not available for
specification with VNLN models.
1
2
CH-40550
VNL Series Economical Wet Location Exit Combo
rev. 1,
dimensions
7-1/2"
(19.1cm)
Max.
22"
(55.9cm)
4-3/4"
(12.1cm)
11-7/8"
(30.2cm)
Square
6-7/8"
(17.5cm)
Some luminaires use fluorescent or high intensity discharge (HID)
lamps that contain small amounts of mercury. Such lamps are labeled,
“Contain Mercury” and/or the symbol “HG”. Lamps that contain
mercury must be disposed of in accordance with local requirements.
Information regarding lamp recycling and disposal can be found at
www.lamprecycle.org
© 2013 Koninklijke Philips Electronics N.V. All rights reserved.
Specifications are subject to change without notice.
Philips Lighting Company
200 Franklin Square Drive
Somerset, NJ 08873
Phone: 855-486-2216
Philips Lighting Company
281 Hillmount Road
Markham ON, Canada L6C 2S3
Phone: 800-668-9008
CH-40550 03/13 www.philips.com/luminaires