HMSP® with Prismetal ® High Mast Luminaires dd AFTER INSTALLATION DELIVER THIS MANUAL TO OWNER IMPORTANT SAFETY INSTRUCTIONS WARNING – READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL OR MAINTAIN THIS FIXTURE. WORK MUST BE DONE BY QUALIFIED PERSONNEL. WARNING – BE CERTAIN THAT ALL ELECTRICAL POWER IS DISCONNECTED FROM THE FIXTURE BEFORE INSTALLING OR MAINTAINING THE FIXTURE. WARNING – FOLLOW LAMP MANUFACTURER’S OPERATING AND MAINTENANCE INSTRUCTIONS. Installation and Maintenance Manual 1.2 Alternate Information Sources. If additional questions arise relative to these luminaires that this document or your supplier cannot answer, please refer them to: Holophane Field Service Department P.O. Box 3004 Newark, OH 43058-3004 (866) 759-1577 2 INSTALLATION 2.1 Tools and Materials Required. Flat Screwdriver Adjustable Wrench 2.2 Luminaire Installation. 2.2.1 Mount the housing assembly to the mounting arm (2” nominal pipe). For installation of photocontrol option see section 2.4. Level the assembly across the top of the housing and tighten the two slipfitter bracket bolts (18-22 ft. lbs.). See Figure 1. FAILURE TO FOLLOW THESE WARNINGS MAY RESULT IN DEATH, INJURY OR SIGNIFICANT PROPERTY DAMAGE. Figure 1 GR482 1 INTRODUCTION GR1021A 1.1 Equipment Description The HMSP® Series luminaire has been listed to applicable U.S. & Canadian safety standards by Underwriters Laboratories Inc. They are suitable for use in wet locations, and ambient temperatures up to 40 degrees Celsius. • • • The luminaire design allows permanent installation of the reflector and housing while still providing easy maintenance and repair of internal components. The lamp and optical glass are directly accessible through the bottom of the reflector. The ballast assembly can be detached for repair by removing four screws and unplugging two electrical connectors. 2.2.2 Route the electrical supply wires from the end of the mounting arm through the notch in wall of the wiring chamber, and connect to the terminal block or fusible disconnect. NOTE Fusible Disconnect Option: With factory installed fusible disconnect for 120 volt, 240 and 277 volt line-to-neutral system, fuse only the line side and connect line side incoming lead to the fusible disconnect. Then attach the white lead to the incoming neutral lead using the supplied wire nut. For 208 volt and 240 volt line-to-line and 480 volt, fuse both line sides and connect both incoming leads to the fusible disconnect. Fuse Kit Accessory: When in-line fusing is specified, see fuse kit instruction sheet. IM-170-C WARNING DO NOT FUSE THE GROUNDING CONDUCTOR. FAILURE TO FOLLOW THIS WARNING MAY RESULT IN INJURY OR DEATH. Figure 3 2.2.3 Make electrical connections to the ballast assembly by joining color-coded plugs and connectors. 2.2.4 Attach the cover (ballast assembly) to the housing using the four screws. Tighten evenly and securely. CAUTION BE CERTAIN THAT NO WIRING IS PINCHED BETWEEN THE COVER AND HOUSING. 2.2.5 Install the correct lamp and energize the luminaire to check for proper operation. ASYMMETRIC DISTRIBUTION 2.3 Optics Orientation The HMSP® Series luminaire produces either Type I Long & Narrow, Asymmetric or Type V Square light patterns. Care must be taken in orienting the light pattern. GR1247 Figure 4 2.3.1 Locate the orientation label located on the reflector. See Figure 2, 3 and 4. 2.3.2 Loosen the three reflector screws only enough to allow the reflector to rotate. 2.3.3 Rotate the reflector to the correct orientation relative to layout requirements and tighten the three screws to 70-80 in-lbs. WARNING RETIGHTEN THE THREE REFLECTOR SCREWS TO THE TORQUE INDICATED. FAILURE TO FOLLOW THIS WARNING MAY RESULT IN INJURY OR DEATH. Figure 2 TYPE V SQUARE DISTRIBUTION GR1022A 2.4 Photocontrol Option The photocontrol receptacle is shipped partially assembled to the housing assembly. If equipped with the photocontrol option, perform the following: 2.4.1 Loosen one of the conduit nuts securing the photocontrol receptacle to the electrical housing. 2.4.2 Rotate the photocontrol receptacle assembly to the position TYPE I LONG & NARROW DISTRIBUTION GR1186 where the receptacle will point straight up after the luminaire is installed. 2.4.3 Securely tighten the nuts to prevent rotation by the wind or vibration. 2.4.4 Loosen the nut securing the receptacle to the elbow and rotate the receptacle to point the arrow marked “N” in a direction that is generally North but not pointing directly toward a nearby luminaire. Securely retighten the nut. 2.4.5 Install a twist-lock type photocontrol into the receptacle. 3 MAINTENANCE 3.1 Relamping and Cleaning. 3.1.1 Disconnect electrical power to the luminaire. 3.1.2 Wipe off the exterior of the luminaire to remove dirt or debris. 3.1.3 Remove the lamp and dispose of it in a safe and legal manner. 3.1.4 Install the correct lamp type and wattage into the lamp socket. 3.1.5 Wipe the inside of the reflector with a soft, dry cloth. The refractor may be washed with water and detergent, if needed. IM-170-C 3.2 Electrical Component Replacement 4 Limited Warranty and Limitation of Liability 3.3 The Holophane limited warranty and limitation of liability is published in the "Terms and Conditions" section of the current Holophane buyer's guide, and is available from your local Holophane sales representative. Electrical components mounted on the ballast assembly can be replaced as follows: (refer to Figure 5) Figure 5 ® Acuity Lighting Group, Inc. 214 Oakwood Ave., Newark, OH 43055 IM-170-C 1/07 ©2002 Acuity Brands Inc. Visit our web site at www.holophane.com Printed in USA GR260A 3.4 3.5 Disconnect electrical power to the luminaire. Wipe off the exterior of the luminaire to remove dirt or debris that could enter when the assembly is removed. 3.6 Remove the screws that secure the cover (ballast assembly) assembly to the housing and tip the cover up. Unplug the electrical connectors. Move the assembly to a horizontal work surface for repair. 3.7 Tag electrical leads for use when installing the new components and note the color-coded plugs and connectors. 3.8 Break electrical connections or cut wires as necessary. 3.9 Remove the attaching hardware and retain for reuse. 3.10 Remove the electrical component. 3.11 Place the new component into position assuring that the locating bosses properly position it. 3.12 Install the attaching hardware. Tighten the fasteners securely. 3.13 Make electrical connections in accordance with wire tags and proper wiring practices. 3.14 Check the interior of the housing and ballast assembly for evidence of damage or potentially hazardous conditions. 3.15 Set the ballast assembly on the housing assembly and make the electrical connections by joining the proper color-coded plugs and connectors. 3.16 Attach the cover (ballast assembly) to the housing using the four screws. Tighten evenly and securely. Be certain that no wiring is pinched between the cover and housing. 3.17 Connect electrical power to the luminaire and check for proper operation. IM-170-C