America’s Boiler Company Firetube Boilers and Accessories Contents PRODUCT PAGE Series 3 Packaged Firetube Boiler..................................................................................................................3 Series 3 Shock Proof Boiler...........................................................................................................................9 Series 3 Packaged Firetube Boiler “Ohio Special”.........................................................................................11 Anticipated Efficiencies.................................................................................................................................13 Wetback vs. Hard Refractory Dryback Design..............................................................................................15 Series 4S 4-Pass Wetback Scotch Boiler.....................................................................................................17 Low Nox Boiler............................................................................................................................................21 Series 4F Forced Draft Firebox Boiler...........................................................................................................23 Series 4F-40 ................................................................................................................................................27 Series 4F-45 ................................................................................................................................................29 Series 4F-50 ................................................................................................................................................31 Series 4F Forced Draft Firetube Boiler “Ohio Special” .................................................................................33 Series 4N Natural Draft Firebox Boiler .........................................................................................................35 Series 4NP Natural Draft Firebox Boiler .......................................................................................................43 C Series Compact Package Boiler ................................................................................................................45 Component Summary Information ..............................................................................................................49 Chemical Feed System ................................................................................................................................52 Bypass and Shot Feed Systems ..................................................................................................................54 Boiler Feedwater System ............................................................................................................................ 56 Condensate Return System ........................................................................................................................ 57 Blowdown Heat Recovery System ...............................................................................................................58 Bottom Blowdown Tank ..............................................................................................................................60 Flash Separator ...........................................................................................................................................62 Bottom Blowdown Separator ......................................................................................................................64 Conductivity Controller ...............................................................................................................................66 Water Softener Systems BS & BP ...............................................................................................................68 Horizontal and Integral Deaerators ..............................................................................................................70 Engineering and Application Data Index ......................................................................................................73 Series 3 Packaged Firetube Boiler Series 3 - Packaged Firetube Boiler Save Thousands Of Dollars Over The Life Of Your Boiler Long-term energy and maintenance efficiencies are the focus of Burnham quality engineering. When choosing a boiler, it’s a good idea to select a product with these features in order to reduce enormous hidden costs down the road. Review our wetback versus dryback literature for cost savings. Boiler Costs Is Not Jus A First Year Proposition With any ordinary boiler, expenses such as fuel, maintenance, and repair costs can escalate as the years go on. Burnham packaged boilers are designed to diminish these significant expenditures. Burnham’s High Life-Cycle Efficiency While most competitive boilers can give fuel-to-steam efficiencies of 80% or over—when they’re new—how consistently can they be expected to maintain this level of operation? Burnham wetback boiler performance will not drop due to deteriorating rear refractory, leaking door baffles and seals, and heat-stressed rear tube sheet as can happen with some drybacks. Easy access is a necessity for those with heavy refractory, since they need frequent and expert maintenance. The Burnham Wetback Saves Big Money On Maintenance Over the life of a dryback, brittle refractory baffling and rear door gasketing will require continuous monitoring, maintenance, and replacement, costing thousands upon thousands of dollars. These built-in maintenance costs can eventually equal or exceed the original cost of the boiler. As refractory deteriorates, leaking hot gas causes boiler efficiency to drop until the condition is noticed and the repairs can be made. Expensive flue temperature alarms are offered with some drybacks to monitor this dangerous and costly potentiality. The rear door itself can become heat-distorted, requiring an expensive replacement. In addition, boiler downtime during repairs can mean crippling losses. This waste of time and money is eliminated with the Burnham Wetback. The actively functional water jacket eliminates the need for: refractory wall, rear door, rear door inspection and sealing, door swing space, and flue temperature alarm. These costly maintenance headaches are gone, while boiler performance is increased. Burnham has only a small, inexpensive refractory area in the burner area, for burner mounting. The rear access door liner is a ceramic fiber insert that contains no refractory. The furnace and rear turnaround area are cool running, fully wetbacked radiant heat transfer surfaces. They promote good internal water circulation and rapid heat absorption. There is no need for the forced internal circulation pumps often specified to cool the rear tube-sheets and drybacks. The Burnham Wetback Is Built To Last Typical dryback boilers have a common rear tubesheet that expands and contracts at different rates adjacent to each tube pass, stressing tube ends and increasing the likelihood of leaks. Additionally, the heavy refractory used in some drybacks reflects intense heat to the rear tube ends and tube sheet, accelerating their deterioration. In attempts to stop leaking, the rear ends of tubes have sometimes been welded. Cleaning or tube replacement involves opening both the front and rear covers and resealing them when the job is done. Usually, if tubes have been welded at the ends, the welds must be burned out, the tube sheet repaired (or a new segment welded in) and the new tubes welded. These costly expenditures are not an issue with the Burnham Scotch Marine: separate rear tube sheets from each pass to expand and contract at its own rate without tube-to-sheet stress. Tubes are rolled and flared in low-pressure units; and rolled, flared and beaded in high-pressure units. No welding of tubes is permitted, nor is it necessary. Any eventual tube replacement is simply a mechanical operation, no welding involved. The end result is less cost and less headache. Series 3 - Ratings and Data Gross Output Heating Surface Net Rating Firing Rate Boiler Model Shell Diam. BHP MBH LBS/ HR Steam MBH Steam Sq. Ft. Water, MBH Sq. Ft. F.S. Sq. Ft. W.S. Gas, MBH Oil, GPH* 40 48 40 1,339 1,380 1,011 4,211 1,164 200 220 1,674 12/11 50 48 50 1,674 1,725 1,290 5,376 1,456 250 280 2,093 60 48 60 2,009 2,070 1,560 6,499 1,747 300 335 70 54 70 2,343 2,415 1,819 7,580 2,037 350 80 54 80 2,678 2,760 2,079 8,663 2,329 90 54 90 3,013 3,105 2,339 9,747 100 54 100 3,348 3,450 2,599 125 66 125 4,184 4,313 150 66 150 5,021 175 66 175 200 66 250 Furn. Vol., Cu. Ft. Water Content Approx. Wt. Dry, Lbs. Lbs. Steam Lbs. Water 15-30 PSI 150 PSI 14.8 1,760 2,185 3,700 4,200 15/14 17.1 2,303 2.701 4,200 4,700 2,500 18/17 19.3 2,765 3,235 4,700 5,200 390 2,930 21/20 27.8 3,285 4,160 5,500 6,200 400 445 3,348 24/23 30.2 3,672 4,641 5,900 6,700 2,620 450 500 3,766 27/25 33.0 4,060 5,143 6,400 7,200 10,830 2,911 500 555 4,185 30/28 35.8 4,523 5,711 6,900 7,700 3,248 13,535 3,638 625 695 5,230 38/25 41.9 5,585 6,673 8,700 9,500 5,175 3,898 16,243 4,366 750 835 6,276 45/42 47.7 6,660 7,947 9,700 10,600 5,858 6,040 4,548 18,950 5,094 875 970 7,333 52/49 53.1 7,758 9,245 10,900 11,600 200 6,695 6,900 5,198 21,658 5,822 1,000 1,110 8,369 60/56 58.8 8,829 10,519 12,300 13,300 78 250 8,369 8,625 6,498 27,074 7,277 1,250 1,360 10,461 75/70 86.6 11,174 13,983 15,400 18,600 300 78 300 10,043 10,350 7,797 32,489 8,733 1,500 1,630 12,500 90/84 99.1 12,315 16,649 18,100 21,400 350 90 350 11,716 12,075 9,096 37,901 10,188 1,750 1,900 14,645 105/98 113.5 15,392 19,340 21,000 23,700 400 90 400 13,390 13,800 10,396 43,317 11,643 2,000 2,175 16,738 120/112 124.7 16,765 22,125 23,200 26,100 500 102 500 16,738 17,250 12,995 54,147 14,555 2,500 2,715 20,923 150/140 152.0 18,515 23,788 27,400 30,600 600 102 600 30,085 20,700 15,594 64,957 17,465 3,000 3,260 25,106 180/168 174.3 22,128 28,381 31,500 35,500 700 102 700 23,433 24,150 18,193 75,805 20,377 3,500 3,805 29,319 210/196 195.8 25,767 33,005 35,700 39,700 800 108 800 26,780 27,600 20,792 86,633 23,287 4,000 4,349 33,475 240/224 302.3 33,945 43,762 43,900 52,900 900 114 900 30,128 33,217 23,500 97,615 N/A 4,500 4,905 37,660 269/252 278 40,893 N/A 47,800 56,600 1000 144 1,000 33,476 34,500 25,990 108,294 N/A 5,000 5,430 41,846 300/280 309 45,437 N/A 51,600 102,200 Note: Dimensions and Data are Not for Construction Purposes and are Subject to Change without Notice • Large, fully waterbacked furnace tube assures complete combustion and heat absorption without flame impingement. • Three gas passes extract maximum usable heat from the fuel while maintaining optimum flow for forced draft firing. • Fully waterbacked reversing chamber effectively absorbs radiant heat into the water, keeping tube ends and rear of boiler cooler than those of hot-running drybacks. • Ready access to tubes through rugged front door and rear covers makes routine cleaning easier and less costly than with drybacks. • Burner does not have to be disturbed. • No inner air baffle door to contend with. • No delicate expensive baffle tiles or door seals to replace. Front View • Unlike dryback boilers, securing the doors on a Burnham wetback boiler requires no specialized skills or expensive repair materials. It is a simple process which can be done with in-house personnel and performed with minimal downtime. Rear View It All Adds Up To Significant Cost-Performance Advantage. What do all these features and specifications mean? More savings for you! Our Packaged Wetback Firetube boilers are designed for long-term efficiency and economical operation, making Burnham your cost-performance leader! • Forced-draft firing with oil (No. 2, 4, 5, or 6), • Low or high pressure steam or water The Series 3 matches burner to boiler, providing a fuelefficient, low-maintenance package. Maintenance costs can be further controlled in your boiler room with optional accessories. Such options include state-of-the-art annunciator systems, custom-designed to monitor all boiler and burner interlocks vital to your specific installation. They provide instant readouts of both normal and abnormal operating conditions. These features will pinpoint the cause of unscheduled shutdowns; reducing maintenance time and skill required. • Highly efficient three-pass design • Fully waterbacked primary heating surfaces • Separate rear tube sheets for longer service life • Wetback design allows easy front and rear access gas or combination gas/oil • No expensive refractory or door replacement as with some drybacks. Series 3 — Standard Equipment Boiler: Three pass full wetback, packaged firetube type, constructed in accordance with requirements of the ASME Code Section IV for 30 psi and 125 psi water or 15 psi steam; Section I for higher pressure steam. All units are registered with the National Board. Boiler tubes are expanded and flared in low pressure boilers; expanded and beaded in high pressure boilers. Turbulator baffles are not used in tubes. Separate second and third pass rear tube sheets allow safe expansion and contraction. Waterbacked rear turnaround promotes rapid internal circulation and reduces gas temperatures at entrance to second pass, reducing tube end stress. Easy opening hinged, insulated front flue doors with lightweight closure provide full access to all tubes. A 16inch diameter bolted rear access door with observation port provides access to the boiler furnace. Rear tube access is provided by removing light weight gasketed door(s) installed in the rear smokebox. No elaborate seals are used. A manhole is furnished as standard on water and low pressure steam boilers sizes 3-125 and larger; on high pressure steam boilers sizes 3-70 and larger. Handhole washouts are provided for easy inspection and cleaning of waterside surfaces. All steam boilers provided with a dry pan to ensure dry steam. A feedwater diffuser is provided on high pressure boilers. All water boilers are equipped with a dip tube at supply outlet and diffuser at return inlet. The round flanged vertical smoke outlet is equipped with a locking quadrant damper. All boilers are provided with an enameled steel jacket over 2 inches of fiberglass insulation, and lifting lugs. The boiler is mounted on a heavy duty structural steel base with extended skid and burner platform for protection of the burner during shipment and rigging. Standard Trim and Controls: Steam: 157 pump control/low water cut-off with alarm contacts–piped with quick opening blowoff valve. Gauge glass set with hand-operated and try cocks. Steam pressure gauge—4 1/2 inch dial on sizes 100 hp and smaller, 6 inch dial on larger sizes. L404C manual reset high limit pressuretrol and appropriate firing rate control when required. Manual reset probe auxiliary low water cut-off. ASME side outlet safety valve(s). Water: 63M manual reset low water cut-off with 30 psi units, 150 low water cut-off with higher pressure units–piped with quick opening blowoff valve. Combination pressure/ temperature gauge–3 1/2 inch dial on 100 hp and smaller. On larger sizes a 6 inch combination pressure/altitude gauge and 5 inch dial temperature gauge. L4006A operating aquastat and L4006E manual reset high limit aquastat and appropriate firing rate control when required. Burner Equipment: Burner mounts to front head of boiler with no elaborate seals. Factory packaged units available with forced draft burners for all commonly used fuels–gas, all grades of oil–No. 2 through No. 6–and combination gas/oil. Choice of pressure or air atomizing burners for No. 2 oil–air atomizing on heavy oil. Gas burners are available for either natural or LP gas. Refer to burner data sheets for standard burner equipment and operating sequence. Accessories and Optional Equipment: Accessories and optional equipment available at extra cost, including, but not limited to: • Solid-state annunciators • Alternate or additional water level controls or low water cut-offs • Built-in tankless heater coils—low-pressure boilers only • Motorized or pneumatic feed valves • Surface skimmers and blowoff valves • Bottom blowdown valves and drain valves • Feed stop and check valves • Sequence draft controls • Lead/lag sequencing systems • Boiler Feed systems • Low NOx burners • Deaerators • Water Softeners • Chemical Feed systems • Blowdown systems • Sample Coolers ©2009 Burnham Commercial - Lancaster, PA Phone: 1-888-791-3790 www.burnhamcommercial.com ASME side outlet safety valve(s). Series 3 Shock Proof Boiler Eliminate any thermal shock concerns with a Series 3-SP Shock Proof hot water boiler package. Our low pressure, 15 psi steam boiler is equipped with a full capacity coil type heat exchanger capable of 125 psi maximum water pressure. Eliminate Thermal Shock… Eliminate any thermal shock concerns with our Series 3-SP Shock Proof hot water boiler package. This boiler design uses our reliable Series 3 that incorporates a high steam space volume that can easily accommodate the industries largest full capacity coil. The Series 3 wetback design and low volumetric furnace release rates allow easy firing and a prolonged boiler life. When properly commissioned and maintained, your shock -proof packaged boiler will last for many years. Shock Proof Benefits • No steam side water make up, no steam side accessories are required. • There is only one initial steam side water treatment required. Since the steam side is sealed, expensive maintenance hours, auxiliary equipment and chemicals are eliminated. A clean steam side will make your boiler run more efficiently. • The hot system water flows only through the tubes of the heat exchanger eliminating thermal stresses and hot water maintenance issues on the boiler side. Shock Proof Features • Specially designed heat exchanger tubes which are highly resistant to corrosion and erosion. • Specially constructed head • Flanged supply and return • Coil trim package included, consists of inlet and outlet pressure gauges, inlet and outlet thermometers and coil side safety valves. • Equipped with a full capacity coil type heat exchanger designed for 125 psi maximum water pressure. Ratings and Data Model Number Output @ Coil Nozzle, MBH, GPM @ 20°F Delta T/180°F/200°F 3L125SP 3L150SP 3L200SP 3L250SP 3L300SP 3L350SP 3L400SP 3L500SP 3L600SP 3L800SP 4,184 5,021 6,695 8,369 10,043 11,716 13,390 16,738 20,085 26,780 420 503 670 840 1,008 1,180 1,340 1,680 2,015 2,755 Delta P thru coil at above flow rate, PSI 5 5 5 5 5 5 5 5 5 5 Head Flange Size, 150# ANSI 4” 4” 5” 6” 6” 6” 8” 8” 8” 8” Performance criteria based on 10 psi boiler operating pressure Flanges orientation may be horizontal, as illustrated, or vertical. Consult factory. Lancaster, PA 17601 Phone: 888-791-3790 www.burnhamcommercial.com 10 Series 3 Packaged Firetube Boiler — “Ohio Special” Three pass full wetback, packaged firetube, constructed in accordance with requirements of the ASME code, section IV for 15-psi steam; Section 1 for higher pressure steam. All units are registered with the National Board. Boiler tubes are expanded and flared in low-pressure boilers; expanded and beaded in high pressure boilers. Separate second and third pass rear tube sheets allow safe expansion and contraction. Waterbacked rear turnaround promotes rapid internal circulation and reduces gas temperatures at entrance to second pass, reducing tube end stress. Easy opening hinged, insulated front flue doors with bolted closure provide full access to all tubes. A 16-inch diameter bolted rear access door with observation port provides access to the boiler furnace. Removing lightweight gasketed door(s) installed on the rear smokebox provides rear tube access. No elaborate seals are used. A manhole is furnished as standard on all Ohio Special Boilers, 100 through 225 hp. Handhole washouts are provided for easy inspection and cleaning of waterside surfaces. The boiler is mounted on a heavy-duty structural steel base with extended skid and burner platform for protection of the burner during shipment and rigging. Standard Trim and Controls All steam boilers are provided with a dry pan to ensure drysteam. A feedwater diffuser is provided on high-pressure boilers. 157 pump control/low water cut-off with alarm, contactspiped with quick opening blowoff valve. Gauge glass set with hand operated gauge and tri-cocks. Steam pressure gauge: 4-1/2 inch dial on 100 HP, 6 inch dial on larger sizes. L404A operating pressuretrol, L404C manual reset high limit pressuretrol and appropriate firing rate control when required. Manual reset probe auxiliary low water cut-off. ASME side outlet safety valve(s). The round-flanged vertical smoke outlet is equipped with a locking quadrant damper. All boilers are provided with an enameled steel jacket over 2 inches of fiberglass insulation and lifting lugs. Ratings and Data 100X 125X 150X 175X 200X 225X Shell Diameter Ratings Gross Output - BHP Gross Output - MBH Gross Output - LBS/HR Net Rating - MBH Net Rating - Sq. Ft. 54 100 3,348 3,450 2,599 10,829 54 125 4,184 4,312 3,249 13,536 54 150 5,021 5,175 3,898 16,244 54 175 5,858 6,037 4,548 18,951 54 200 6,695 6,900 5,198 21,658 54 225 7,532 7,762 5,848 24,366 Safety Valve Safety Valve 3,450 3,906 4,312 4,882 5,175 5,858 6,037 6,834 6,900 7,811 7,762 8,787 358 383 358 383 358 383 358 383 358 383 358 383 (15 PSIG) - LBS/HR (150 PSIG) - LBS/HR Heating Surface - Sq. Ft. Fireside Waterside Firetubes Number Diameter - Inches 46 2.5 46 2.5 46 2.5 46 2.5 46 2.5 46 2.5 Furnace Volume - Cu. Ft. Diameter - Inches 30.5 25 30.5 25 30.5 25 30.5 25 30.5 25 30.5 25 Firing Rate 100 BTU Gas - MBH 140 MBTU/Gal. Oil - GPH 150 MBTU/Gal. Oil - GPH 4,184 29.9 27.9 5,230 37.4 34.9 6,277 44.8 41.8 7,323 52.3 48.8 8,369 59.8 55.8 9,415 67.2 62.8 11 Dimensions (in inches) 100X 125X 150X 175X 200X 225X A - Base Width B - Furnace Center C - Overall High Pressure Supply Connection Overall Low Pressure Supply Connection 38 33-5/16 76-5/8 76-5/8 38 33-5/16 76-5/8 76-5/8 38 33-5/16 76-5/8 76-5/8 38 33-5/16 76-5/8 76-5/8 38 33-5/16 76-5/8 76-5/8 38 33-5/16 76-5/8 76-5/8 D - Width over Trim E - Width over Jacket F - Base to N.W.L. G - Overall Length 69-1/4 59-1/4 59-3/4 190-1/2 69-1/4 59-1/4 59-3/4 190-1/2 69-1/4 59-1/4 59-3/4 190-1/2 69-1/4 59-1/4 59-3/4 192-1/2 69-1/4 59-1/4 59-3/4 192-1/2 69-1/4 59-1/4 59-3/4 194-1/2 H - Base Length J - Front to High Pressure Feed Connection K - Base Extension L - Flue Door Clearance 159-3/4 93-1/8 35-3/4 29-1/2 159-3/4 93-1/8 35-3/4 29-1/2 159-3/4 93-1/8 35-3/4 29-1/2 159-3/4 93-1/8 35-3/4 29-1/2 159-3/4 93-1/8 35-3/4 29-1/2 159-3/4 93-1/8 35-3/4 30-3/4 M - Tube Removal Space N - High Pressure Supply Size Low Pressure Supply Size P - Shell Length over Flue Outlet 125 4” flg 8” flg 154-3/4 125 4” flg 8” flg 154-3/4 125 4” flg 8” flg 154-3/4 125 6” flg 8” flg 156-3/4 125 6” flg 8” flg 156-3/4 125 6” flg 8” flg 158-3/4 Q - Front to Supply R - High Pressure Supply to Manway Low Pressure Supply to Manway S - Flue Outlet Flange Diameter 60-1/8 33 33 17 60-1/8 33 33 17 60-1/8 33 33 17 60-1/8 33 33 17 60-1/8 33 33 17 60-1/8 33 33 17 T - Flue Inside Diameter U - Outside Flange to Center V - Floor to Flue Outlet Flange 13-3/8 8-1/2 74-3/8 13-3/8 8-1/2 74-3/8 13-3/8 8-1/2 74-3/8 15-1/2 9-1/2 74-3/8 15-1/2 9-1/2 74-3/8 17-1/2 9-1/2 74-3/8 W - Floor to High Pressure Feed Connection X - Feed Connection Size 43-5/16 1-1/4 43-5/16 1-1/4 43-5/16 1-1/4 43-5/16 1-1/2 43-5/16 1-1/2 43-5/16 1-1/2 5,536 664 5,536 664 5,536 664 5,536 664 5,536 664 5,536 664 7,000 12,450 8,100 13,550 7,050 12,450 8,150 13,550 7,100 12,500 8,200 13,600 7,500 12,950 8,600 14,050 7,650 13,050 8,750 14,150 7,650 13,050 8,750 14,150 Water Content LBS Gallons Approximate Shipping Weight Low Pressure (Dry) - LBS Low Pressure (Wet, N.W.L) - LBS High Pressure (Dry) - LBS High Pressure (Wet, N.W.L.) - LBS © 2006 Burnham Commercial - Lancaster, PA Phone: 1-888-791-3790 www.burnhamcommercial.com 12 Anticipated Efficiencies Natural Gas 125% 50% 75% 100% BOILER SIZE 10 # 125 # 10 # 125 # 10 # 125 # 10 # 125 # 100 125 150 200 82.50 81.00 82.00 82.50 78.50 77.00 78.00 79.00 83.50 82.00 83.00 83.50 80.50 79.00 80.00 80.50 83.50 82.00 83.00 83.50 81.00 79.50 80.50 81.00 83.50 82.00 83.00 83.50 81.00 79.50 80.50 81.50 250 300 350 400 500 600 81.50 82.00 82.50 82.00 82.50 83.00 78.00 78.50 78.50 78.00 79.00 79.50 82.00 82.50 83.00 83.00 84.00 84.00 79.50 80.00 80.50 80.00 81.00 81.00 82.00 82.50 83.00 83.00 84.00 84.50 80.00 80.50 81.00 80.50 81.50 82.00 82.00 82.50 83.00 83.00 84.00 84.50 80.00 80.50 81.00 80.50 81.50 82.00 700 800 1000 83.00 83.50 83.50 79.50 80.00 80.00 84.50 84.50 84.50 81.50 81.50 81.50 84.50 84.50 84.50 82.00 82.00 82.00 84.50 84.50 84.50 82.00 82.00 82.00 #2 Oil 125% 50% 75% 100% BOILER SIZE 10 # 125 # 10 # 125 # 10 # 125 # 10 # 125 # 100 125 150 200 85.50 84.00 85.00 86.00 81.50 80.00 81.00 82.00 86.50 85.00 86.00 87.00 83.50 82.00 83.00 84.00 86.50 85.50 86.50 87.00 84.00 82.50 83.50 84.50 86.50 85.50 86.50 87.00 84.00 82.50 83.50 84.50 250 300 350 400 500 600 85.00 85.50 85.50 85.00 86.00 86.00 81.50 81.50 82.00 81.50 82.00 82.50 85.50 86.00 86.50 86.00 87.00 87.50 83.00 83.50 84.00 83.50 84.00 84.50 85.50 86.00 86.50 86.50 87.50 87.50 83.00 83.50 84.50 84.00 85.00 85.00 85.50 86.00 86.50 86.50 87.50 87.50 83.00 83.50 84.50 84.00 85.00 85.00 700 800 1000 86.50 87.00 87.00 82.50 83.00 83.00 87.50 88.00 88.00 84.50 85.00 85.00 88.00 88.00 88.00 85.50 85.50 85.50 88.00 88.00 88.00 85.50 85.50 85.50 13 Thermal Efficiency The effectiveness of the boiler as a heat exchanger. It is the ability of the boiler to exchange heat through tubes and furnace, by radiation, conduction and convection, to the transfer medium (water). A few of the factors affecting thermal efficiency are heating surface, tube number and diameter, furnace tube length and diameter. Combustion Efficiency This is a measure of the ability of the burner to effectively and completely burn the fuel, coupled with the thermal efficiency of the boiler. Burners requiring high amounts of excess air to provide flame stability will be less efficient. Combustion efficiency does not take into account heat loss to the surrounding air through the boiler jacket and piping. Fuel to Steam Efficiency Sometimes referred to as overall efficiency. This is a ratio of heat output to heat input. This includes boiler jacket and piping losses to the surrounding environment. It is the percent of useable heat in the steam (or hot water) compared to the heat input supplied by the burner. It is also defined as the combustion efficiency less boiler jacket and piping loss (radiation and convection losses). Since fuel-to-steam efficiency reflects the portion of actual usable heat supplied to the system, it is most useful when comparing performance of similar equipment, or when doing fuel savings analysis. BOILER RATINGS Ratings may be expressed in the following units: BHP = Boiler Horsepower. One BHP is the evaporation of 34.5 lbs of 212°F water per hour into dry saturated steam at the same temperature. BTUh BHP = 33,475 BTUh/BHP BTU = British Thermal Units: that quantity of heat required to raise one (1) lb. of water one (1) degree on the Fahrenheit scale. BTUh = BTU/hr. MBH =1000 BTUh PPH = Pounds of steam per hour MBH PPH = 0.9703 MBH/PPH Gross Rating – The full output of a boiler actually available to the heating or process system at the outlet nozzle. The Commercial Steel Boiler Industry catalogs gross output as 80% of input. Net Ratings – The net connected design load that can be supplied with heat by a boiler of given output, allowing for normal system piping losses and pickup from a cold start. Since steam system piping losses may be expected to be larger than for water systems, and steam boilers require greater heat input from a cold start than water boilers before heat flows to the system, steam net ratings for automatic fired boilers are slightly lower in relation to gross output than water net ratings. Hand fired net water and steam ratings are equal and are lower in relation to gross output in order to provide ample allowance for rapid pickup from a banked fire. MBH net water = Gross MBH x 0.87 MBH net steam = Gross MBH x 0.776 Square Foot Ratings – Net ratings based on a heat emission rate of 240 BTUh per square foot of radiation for steam, and 150 BTUh per square foot for water. Square Feet Net Steam = Steam Net MBH Square Feet Net Water = 0.24 MBH / sq. ft. 14 Water net MBH 0.15 MBH / sq. ft. Wetback Design vs. Hard Refractory Dryback Design Why is a Wetback design better? Burnham’s three-pass wetback design has a rear water wall, which separates the primary heating surface of the combustion chamber from the rear tube sheet. The water jacket eliminates the need for a refractory wall and rear door swing space behind the boiler, as well as costly refractory maintenance. The rear water wall eliminates the need for gasketing, which is vulnerable to the temperature generated in the rear of the turnaround area. A wetback design boiler not only overcomes these expensive deficiencies, but it has great overall efficiency and virtually maintenance-free construction. A Burnham boiler will cost you less over the lifetime of the boiler because it is better by design! Some Points to Remember: Wetback Advantages • • • • • • Wetback boilers have separate tube sheets between all major temperature changes. The rear access door is constructed of lightweight ceramic fiber The rear doors require no cool-down period and can be opened immediately No space consuming area required for the swing door The split rear flue doors are easily removed Efficiency is readily maintainable because the design of the boiler promotes complete and even circulation of flue gases Dryback Disadvantages • • • • • Flue gas temperature differential of 1300F-1600F between the second and third passes creates damaging stresses on the single tube sheet. The cost of rear door refractory replacement (approximately every three years) will drastically increase operating costs, as well as the costs associated with yearly rear door gasket replacement. Opening and resealing the rear door is time consuming and requires a 24-hour cool down period prior to opening The heavy refractory may sag on the davit and must be rigged back into place. Heavy jacks or expensive rigging may be required just to open and close the rear doors Exposing the refractory to hot flue gases can cause erosion and destroy the baffle; resulting in the uneven circulation of flue gases and lower efficiency Rear refractory walls radiate unabsorbed heat, leading to external heat loss 15 WHAT IS FUEL-TO-STEAM EFFICIENCY AND IS IT IMPORTANT? Fuel-to-steam efficiency is very important because it is the only true measure of overall packaged boiler operational efficiency. True fuel-to-steam efficiency takes into account radiation and convection heat losses, which less reputable manufacturers may ignore. We suggest purchasing your boiler from a manufacturer who guarantees fuel-to-steam efficiency in the performance of your entire packaged boiler. Be wary of misleading efficiency terms, such as “thermal efficiency” or “combustion efficiency”. Contact your local Burnham Commercial sales representative for further definition. MAINTAINABLE EFFICIENCY VS. ATTAINABLE EFFICIENCY When looking at efficiency as criteria for purchasing a boiler, especially fuel-to-steam efficiency, the manufacturer’s design efficiency sets theoretical fuel costs while operation efficiency determines actual fuel costs. There is a difference between attainable efficiency and maintainable efficiency. Correct burner adjustments are the key to maintainable efficiency. It is a compromise between the optimum and the practical. Good burner tuning is achievable only with a good burner design and a good burner/boiler package. WILL A DRYBACK BOILER COST MORE TO OWN? The answer is simple…Yes! The high cost of maintenance is the biggest consideration in overall efficiency in a dryback design. Consider this example: an average 300 HP boiler operating under normal conditions with a conservative lifespan of 25 years. Our surveys have shown that during this boiler’s lifetime the rear door refractory would be replaced about 8 times (roughly every three years). Also, assuming the boiler is opened only once a year for inspection, regasketing of the rear door would occur 25 times. How much cheaper is the hard refractory backed boiler? So, somebody is offering a hard refractory backed boiler design for less money than a wetback design! While it may make your initial capital investment costs look great, what does it do to your pocketbook in the long run? Let’s take a look.... Average cost for replacing rear door hard refractory: $6,000 Average cost of regasketing the rear door: $500 Apply these costs to the average lifespan of the boiler: $6,000 X 8 = $48,000 $500 X 25 = $12,500 Compare the costs of replacing the rear door gasket of your wetback design: $30 X 25 = $750 The difference between the hard refractory dry back maintenance and the wetback maintenance is $60,500 - $750 = $59,750. Now comes the shocking part...for the same amount of money spent in dryback maintenance: YOU COULD HAVE PURCHASED A NEW BURNRHAM WETBACK BOILER! 16 Series 4S 4-Pass Wetback Scotch Boiler 17 4-Pass Wetback Scotch Boiler America’s Boiler Company The Burnham Commercial Series 4S four-pass wetback scotch boiler was designed using our 140+ years of boiler experience and is sold and serviced through the largest and most experienced network of sales representatives in the country. With a complete commercial product offering and unmatched sales and technical support, it’s no wonder why we are America’s Boiler Company! Why Choose the Series 4S? • The design incorporates positive water flow circulation and maximum heat transfer to maximize ratings. • The handhole clean-outs are placed for ease of servicing. • The heavy steel base provides adequate stability along with shipping and rigging protection. • • It is completely packaged and ready for “same day” installation. The 5 sq.ft./hp rated design does not use turbulators or welded tube ends. • The multitude of QC checkpoints and stringent final inspection assures you of a quality product. • There are no proprietary parts or gaskets on the boiler trim or the burner. Latest Design Techniques • All external trim piping is designed and installed in accordance with the ASME Code and is certified by an independent inspection agency for compliance. The Series 4S uses the very latest design techniques and standards. Its furnace, the workhorse of the boiler, is designed for low volumetric release rates of no more than 136,000 btu/hr/cu.ft. The lower the release rates, the “easier” your boiler works. As your boiler works easier, less stress is put upon the steel, tube ends, refractory, etc., resulting in a longer lasting boiler. In addition to longevity, a larger furnace makes for ease in firing using any selected burner vendor. The Series 4S is also easily converted to a low NOx product when needed. • The fiberglass insulated steel jacket is finish painted with high gloss Burnham blue enamel. Higher Efficiency • The access door is constructed of durable, lightweight vacuum formed ceramic fiber—the door liner weighs less than 40 pounds! • The front and rear full-sized hinged access doors are standard and secured with non-corrosive brass nuts. • The UL approved packaged burners are trimmed and wired to assembled gas trains. The Burnham Series 4S design produces a higher efficiency due to the larger furnace and higher heat transfer design. To determine the efficiency of your next job, contact your local Burnham representative. 4 Pass Wetback Scotch Boiler—To learn more about wetback versus dryback, please refer to our wetback literature 18 Dimensions and Ratings A 100 125 150 175 200 250 300 350 400 500 600 700 800 68 68 76 76 76 86 86 94 94 104 104 114 114 B 84 85 93 93 93 103 103 111 111 121 121 131 131 C 150 176 169 188 207 207 235 240 263 264 300 282 311 Dimensions are approximate, see detailed drawings for more specific dimensions. Rating Data Boiler Size, HP 100 125 150 175 200 250 300 350 400 500 600 700 800 Shell Diameter 62 62 70 70 70 70 78 88 88 98 98 108 108 Gross Output, BHP 100 125 150 175 200 250 300 350 400 500 600 700 800 Gross Output, MBH 3348 4184 5021 5858 6695 8369 10,043 11,716 13,390 16,738 20,085 23.433 26,780 Gross Ouput, Lbs./Hr. 3450 4312.5 5175 6037.5 6900 8625 10,350 12,075 13,800 17,250 20,700 24,150 27,600 Heating Surface, FS Sq. Ft. Firing Rate - Gas Gas - MBH Oil - GPH (140 MBTU/Gal.) 500 625 750 875 1000 1250 1500 1750 2000 2500 3000 3500 4000 4184 29.9 5230 37.4 6277 44.8 7323 52.3 8369 59.8 10,461 74.7 12,553 89.7 14,645 104.6 16,738 119.6 20,922 149.4 25,106 179.3 29,291 2092 33,475 239.1 39 46 58 66 73 93 108 133 149 177 206 219 246 Furnace Volume - Cu. Ft. Heat Releases Rate BTU/Hr./Cu. Ft. Water Content Flooded - Gal. NWL - Gal. Shipping Weight - Lbs. 15/30 psi 125/150 psi 107,618 112,686 108,471 111,565 114,003 112,617 116,193 110,011 112,491 118,528 121,670 133,559 136,013 875 779 1,115 995 1,187 1,019 1,391 1,187 1,606 1,367 1,750 1,487 2,110 1,786 2,661 2,266 3,045 2,601 3,536 2,818 4,256 3,405 4,747 3,932 5,431 4,507 8,000 8,900 9,940 10,400 10,500 11,700 12,000 13,200 13,200 14,400 15,600 19,000 18,300 21,600 22,300 21,600 24,500 27,600 28,900 32,300 33,200 37,100 38,300 45,100 42.500 50,000 19 Series 4S Standard Equipment Boiler: Four-pass full wetback firetube type, constructed in accordance with requirements of the ASME Code, Section IV for 30 PSI and 125 PSI water or 15 PSI steam; Section I for higher-pressure steam. All units are registered with the National Board. Water: 63M manual reset low water cut-off with 30 PSI units, 150M low water cut-off with higher-pressure units—piped with quick opening blowoff valve. Combination pressure/ temperature gauge—3 ½ inch dial on 125 HP and smaller. On larger sizes a 6-inch combination pressure/altitude gauge and 5-inch dial temperature gauge. L4006A operating aquastat and L4006E manual reset high limit aquastat and appropriate firing rate control when required. ASME side outlet relief valve(s). Turbulator baffles are not used in tubes. Separate rear tube sheets allow safe expansion and contraction. Waterbacked rear turnaround promotes rapid internal circulation and reduces gas temperatures at the entrance to the second pass, reducing tube end stress. Burner Equipment: Easy opening hinged, insulated front flue doors with light weight non-refractory closure provide full access to all tubes. A light weight 16-inch diameter bolted rear access door with observation port provides access to the boiler furnace. Rear tube access is provided by removing lightweight gasketed doors(s) installed on the rear smokebox. No elaborate seals are used. Burner mounts directly to the front head of the boiler with no elaborate seals. Factory packaged units available with forced draft burners for all commonly used fuels—gas, all grades of oil—No. 2 through No. 6—a combination gas/oil. Choice of pressure or air atomizing burners for No. 2 oil—air-atomizing burners for No. 2 oil—air atomizing on heavy oil. Gas burners are available for either natural or LP gas. A manhole is furnished as standard. Handhole washouts are provided for easy inspection and cleaning of waterside surfaces. Refer to burner data sheets for standard burner equipment and operating sequence. All steam boilers are provided with a dry pan to ensure dry steam. A feedwater diffuser is provided on high-pressure boilers. All water boilers are equipped with a dip tube at supply outlet and diffuser at return inlet. Accessories and Optional Equipment: Accessories and optional equipment available at extra cost, including, but not limited to: • Alternate or additional water level controls or low water cut-offs • Built-in tankless heater coils—low-pressure boilers only • Motorized or pneumatic feed valves • Surface skimmers and blowoff valves • Bottom blowdown valves and drain valves • Feed stop and check valves • Sequence draft controls • Lead/lag sequencing systems • Boiler Feed systems • Low NOx burners • Deaerators • Water Softeners • Chemical Feed systems • Blowdown systems • Sample Coolers The round-flanged vertical smoke outlet is equipped with a quadrant damper. All boilers are provided with an enameled steel jacket installed over 2 inches of fiberglass insulation and lifting lugs. The boiler is mounted on a heavy-duty structural steel base with extended skid and burner platform for protection of the burner during shipment and rigging. Standard Trim and Controls: Steam: 157 pump control/low water cut-off with alarm contacts—piped with quick opening blowoff valve. Gauge glass set with hand-operated gauge and try cocks. Steam pressure gauge—4 ½-inch dial on sizes 125 HP and smaller, 6-inch dial on larger sizes. L404A operating pressuretrol, L404C manual reset high limit pressuretrol and appropriate firing rate control when required. Manual reset probe auxiliary low water cut-off. ASME side outlet safety valve(s). Lancaster, PA 17601 Phone: 888-791-3790 www.burnhamcommercial.com 20 Low NOx 21 Low NOx America’s Boiler Company Combining these three features contribute to an ideal low NOx package application. Burnham Commercial has been designing and producing boilers for 140+ years, and we sell and service through the largest and most experienced network of sales representatives in the country. Our representatives are capable of providing technical assistance, competent pricing, start-up, and long term servicing. It’s no wonder we are America’s Boiler Company! Our firebox design provides the largest furnace possible in a firetube, and our scotch boilers have some of the largest furnaces available in our market—meaning we can meet all your Low NOx needs. Important Design Considerations Low NOx Needs Our proven designs use the very latest low NOx techniques and standards. Our furnace, the workhorse of the boiler, is designed for low volumetric heat release. The lower the release rates, the “easier” your boiler works. As your boiler works easier, less stress is put upon the steel, tube ends, refractory, etc., resulting in a longer lasting boiler. In addition to longevity, a larger boiler makes for ease in firing using any selected burner vendor. Being America’s Boiler Company, we know what burner vendors are looking for in boiler designs when it comes to reduced NOx combustion levels—large furnaces, high heat transfer, and low draft losses: • Large furnaces mean low volumetric release rates. • High heat transfer for the most efficient boiler for your application. • Less burner motor horsepower so less energy is used to operate your boiler. Smaller furnaces are extremely susceptible to erratic flame patterns. Deformed flame patterns cause uneven heat distribution, uneven absorption and localized hot spots, which can lead to overheating and over stressing. Our selections give the customer the choice of any of the major low NOx burner manufacturers. Because we have so many proven product design selections to choose from, we can custom fit any of our products to your boiler room. Burnham Commercial can offer you firebox, threepass or four-pass wetback scotch. We are the only manufacturer who can offer their packages complete with flue gas recirculation piping, when necessary. That eliminates extra design responsibility and field installation costs. Proven Product Applications Unlike any other manufacturer, every Burnham Commercial Low NOx package is design application approved by our own Engineering Department and our burner vendors’ Engineering and Applications Design Groups. Our 140+ years successful track record assures you that our products, and our vendor selection, are the best available. Lancaster, PA 17601 Phone: 888-791-3790 www.burnhamcommercial.com 22 Series 4F Forced Draft Firebox Boiler 23 Series 4F Forced Draft Firebox Boiler The Versatile Boiler The Burnham Commercial 4F forced draft steel firebox boiler is a consistent sales leader in the heating industry. Its compact and constructive design saves on installation, operation, and maintenance. 4F Saves on Installation The 4F is a compact boiler that fits where other designs of similar capacity cannot. Available for 15 psi steam and 30 or 60 psi water*, the 4F can serve perfectly as the heart of almost any system. As a factory assembled, forced-draft fired boiler, this packaged unit does not require a tall, expensive vent stack or excessive jobsite time and labor. 4F Saves in Operation • The furnace surrounds the flame with highly efficient waterbacked primary heat absorbing surfaces. This large combustion chamber is easy to fire and accommodates many forced-draft burners without flame impingement or other critical firing problems. • Forced draft firing makes the 4F inherently more efficient than boilers using outmoded atmospheric burners and gives you a feature that atmospheric units cannot offer: the option of burning gas or oil. • A dual fired burner allows you to burn the more economical fuel or the most readily available fuel at the flip of a switch and affords you leverage in negotiating fuel prices. • The 4F is an economical heat source, whether used singly or in multiples. In fact, 4F’s with modulating burners may be sequenced to operate in a step-fired system more cost effectively than a large number of space saver boilers when ongoing maintenance costs are considered. 4F Saves on Maintenance • Superior design makes the 4F easy to clean and maintain — requiring no special tools, materials, or skills. • Opening the front flue door allows firetubes to be brushed out quickly, unlike the watertubes used in some boilers which can be virtually impossible to clean. • Elaborate or expensive proprietary seals are not required to re-close the doors as with some boilers. • As a wetback boiler, there is no delicate or expensive rear refractory to maintain. *60-psi water boiler - consult factory for available sizes. 24 Series 4F — Models 63 - 675 Dimensions (in Inches) 4F Boiler Models 63 78 92 107 A - Boiler Width 31 31 31 31 32 39 B - Boiler Length 127 154 180 209 240 277 311 36-3/8 36-3/8 36-3/8 36-3/8 45-1/8 45-1/8 45-1/8 45-1/2 52-1/2 44-1/2 53 61 70 57 65 72-1/2 C - Boiler Height 55-1/4 55-1/4 55-1/4 55-1/4 63-5/8 63-5/8 63-5/8 63-5/8 70-5/8 70-5/8 70-5/8 D - Base Width 33-1/4 33-1/4 33-1/4 33-1/4 38-5/8 38-5/8 38-5/8 38-5/8 47-3/8 47-3/8 47-3/8 E - Base Length 47-1/2 54-1/2 65 72 64 72-1/2 80-1/2 92-1/2 79-1/2 87-1/2 95 345 360 450 45-1/8 52-3/4 52-3/4 563 675 56-1/2 56-1/2 80 80-3/4 93-1/4 104-3/8 122-1/4 70-5/8 82-7/16 82-7/16 85-3/16 85-3/16 47-3/8 53-1/8 53-1/8 57 57 102-1/2 107-1/2 124 135-1/8 153 F - Base Extension 15-1/2 15-1/2 19-1/2 19-1/2 19-1/2 19-1/2 19-1/2 22-1/2 22-1/2 22-1/2 22-1/2 22-1/2 26-3/4 30-3/4 G - Front Smoke Box Height 27-5/16 27-5/16 27-5/16 27-5/16 29-7/16 29-7/16 29-7/16 29-7/16 35-1/8 35-1/8 35-1/8 35-1/8 38-1/2 38-1/2 41-9/16 41-9/16 H - Front Smoke Box Depth 30-3/4 30-3/4 5-1/2 5-1/2 5-1/2 5-1/2 6-1/2 6-1/2 6-1/2 6-1/2 7-1/2 7-1/2 7-1/2 7-1/2 6-1/2 6-1/2 7-1/2 7-1/2 J - Supply Location 13 13 13 13 16 16 16 16 19 19 19 19 28 28 28 28 *K - Supply Size 4 4 4 4 6 6 6 6 6 8 8 8 8 10 10 10 *L - Return Size - Steam 3 3 3 3 4 4 4 4 4 4 4 4 4 4 4 4 6-1/2 6-1/2 6-1/2 6-1/2 7 7 7 7 7 7 7 7 7-3/8 7-3/8 7-3/8 7-3/8 7 7 7 7 10 10 10 10 12 12 12 12 — — — — — — — — 14 14 18 18 M - Return Location N - Top Vent Collar Dia. P - Rear Vent Collar Dia. — — — — Q - Rear Vent Collar Height 38 38 38 38 9 9 9 9 R - Smoke Box Depth T - Top Vent Collar Height U - Tube Pull Space V - Supply Fitting Height 46-1/2 46-1/2 46-1/2 46-1/2 12 12 12 12 — — — — 52 52 52 52 14 14 14 42-1/2 42-1/2 42-1/2 42-1/2 52-1/2 52-1/2 52-1/2 52-1/2 59-1/4 59-1/4 59-1/4 32 39 1-1/2 1-1/2 45-1/2 52-1/2 44-1/2 1-1/2 1-1/2 3-1/4 58-13/16 58-13/16 59-5/8 59-5/8 14 16 59-1/4 66-5/16 81-1/2 16 53 61 70 57 65 72-1/2 80 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-3/8 3-3/8 58 58 58 58 69-3/16 69-3/16 W - Normal Water Line Height 43-3/4 43-3/4 43-3/4 43-3/4 51-1/2 51-1/2 51-1/2 51-1/2 *3” and 4” are IPS female thread, 6” and larger are flanged. 150# bolt pattern. Specifications, Dimensions Data Subject to Change without Notice 25 20 20 66-5/16 69-1/8 69-1/8 94 105 123 3-7/16 3-7/16 72 72 Series 4F — Models 827 - 3075 The Complete Boiler Room Supplier Dimensions (in Inches) 4F Boiler Models 827 993 1157 1323 1654 1985 2315 2645 A - Boiler Width 64 64 70 70 76 82 82 82 3075 96 B - Boiler Length 106-1/4 129 116-1/2 136 130-1/2 128 148 163 163 C - Boiler Height 151-1/2 95-3/16 95-3/16 106-3/4 106-3/4 122-3/8 142-3/8 142-3/8 142-3/8 D - Base Width 61 61 67 67 73 79 79 79 93 E - Base Length 138-1/4 161 158-1/2 178 172-1/2 170 190 205 213 F - Base Extension 30 30 40 40 40 40 40 40 48 G - Front Smoke Box Height 29-1/8 29-1/8 33-11/16 33-11/16 41-7/8 55-1/8 55-1/8 55-1/8 69-3/4 H - Front Smoke Box Depth 12-3/4 12-3/4 13-1/2 13-1/2 14-1/2 15-1/2 15-1/2 15-1/2 16-1/2 J - Supply Location 22 22 22 22 22 22 22 22 68 *K - Supply Size 8 8 8 8 10 12 12 12 12 *L - Return Size - Steam 4 4 4 6 6 6 6 6 6 Return Size - Water 6 6 6 8 8 8 8 8 8 M - Return Location 10-1/4 10-1/4 11-1/8 11-1/8 11-1/8 11-1/2 11-1/2 11-1/2 10-1/2 N - Rear Smoke Box Depth 19-3/8 19-3/8 19-3/8 19-3/8 21-3/8 23-3/8 23-3/8 23-3/8 23-3/8 20 20 22 22 24 28 28 28 30 66-3/16 66-3/16 76-13/16 76-13/16 90-11/16 106-5/16 106-5/16 106-5/16 110-1/2 R - Top Vent Collar Width 22 22 26 26 28 34 34 34 44 S - Top Vent Collar Depth 16 16 16 16 18 20 20 20 20 T - Top Vent Collar Height 76-1/8 76-1/8 87-3/ 87-3/4 102-5/8 120-1/4 120-1/4 120-1/4 123-15/16 108 131 118-1/2 138 132-1/2 130 150 165 165 78-1/4 78-1/4 89-3/4 89-3/4 104-1/2 118-1/2 118-1/2 118-1/2 126 P - Rear Vent Collar Dia. Q - Rear Vent Collar Height U - Tube Pull Space W - Normal Water Line Height *4” are IPS female thread, 6” and larger are flanged. 150# bolt pattern. Specifications, Dimensions Data Subject to Change without Notice © 2008 Burnham Commercial - Lancaster, PA Phone: 1-888-791-3790 www.burnhamcommercial.com 26 Series 4F-40 Forced Draft Firebox Generator Ratings and Data 63 78 92 107 127 154 180 209 240 277 311 345 360A 450A 563A 675A Gross Output MBH BHP Lbs. Stm/Hr 527 15.7 543 653 19.5 673 770 23.0 794 896 26.8 923 1,063 31.8 1,096 1,289 38.5 1,328 1,506 45.0 1,553 1,749 52.2 1,803 2,009 60.9 2,070 2,318 69.2 2,389 2,603 77.8 2,683 2,887 86.2 2,975 3,015 90.1 3,108 3,770 112.6 3,885 4,720 141.0 4,864 5,657 169.0 5,832 Net Rating - Steam MBH Sq. Ft. 409 1,705 507 2,115 598 2,490 695 2,895 825 3,445 1,000 4,165 1,169 4,870 1,357 5,655 1,559 6,495 1,799 7,495 2,020 8,415 2,240 9,335 2,340 2,926 3,663 4,390 9,750 12,190 15,265 18,295 Net Rating - Water MBH 458 568 670 780 925 1,121 1,310 1,522 1,748 2,017 2,265 2,512 2,623 3,280 4,106 4,922 Firing Rate - Gas MBH Firing Rate - Light Oil GPH* Heavy Oil GPH* 659 4.7 — 816 5.8 — 963 6.9 — 1120 8.0 — 1329 9.5 — 1,611 11.5 — 1,883 13.5 — 2,186 15.6 — 2,511 17.9 — 2,898 20.7 — 3,254 23.2 — 3,609 25.8 — 3,769 26.9 25.1 4,713 33.7 31.4 5,900 42.1 39.3 7,071 50.5 47.1 Heating Surface Sq. Ft. Fireside Waterside 59 63 73 78 86 92 101 107 120 127 145 154 168 180 194 209 224 240 257 277 289 311 320 345 360 398 450 497 563 622 675 746 Furnace Volume Cu. Ft. 8.8 10.7 12.6 14.6 18.3 21.9 25.3 29.1 34.7 39.7 44.4 49.1 58.9 68.0 89.3 104.7 Heat Release MBH/Cu. Ft. 74.9 76.3 76.4 76.7 72.6 73.6 74.4 75.1 72.4 73.0 73.3 73.5 64.0 69.3 66.1 67.5 65 90 81 112 94 132 110 153 133 168 145 196 172 232 198 268 214 288 245 329 274 369 302 408 470 569 551 666 663 881 788 951 Approx. Dry Weight Lbs. 1,700 1,900 2,100 2,600 2,700 3,100 3,300 3,600 4,200 4,400 5,300 5,600 6,710 8,700 Approx. Full Weight Lbs. Steam Water 2,240 2,450 2,570 2,835 3,090 3,195 3,510 3,870 3,800 4,095 4,300 4,735 4,730 5,235 5,250 5,830 5,980 6,595 6,435 7,140 7,575 8,365 8,110 10,615 13,290 14,825 16,970 8,995 11,495 14,255 15,975 18,325 4F - 40 Boiler Models Water Content Gal. Steam Water Ratings based on 4 square feet of heating surface per boiler horsepower * Light oil—140,000 BTU/GAL ** Heavy oil,—150,000 BTU/GAL Instantaneous Hot Water Heating Coils Rated Capacity — Gallons Heated 40° to 140°F Boiler Water Temp. 108°F 180°F 212°F GPM GPH GPH 3.5 210 325 Coil Number INA-210 *For Use in the Following Boiler Sizes Subject to Capacity Limitation of Boiler All sizes INA-300 All except 4F-63 5.0 300 466 INA-360 All sizes 6.0 360 560 INA-450 All except 4F-63 7.5 450 700 INA-600 4F-154 and larger, also 4F-107 10.0 600 933 INA-750 4F-154 and larger, also 4F-107 12.5 750 1,165 INA-900 4F-92 and larger 15.0 900 1,400 INA-1125 4F-154 and larger 18.7 1,125 1,750 INA-1350 4F-277 and larger, also 4F-209 22.5 1,350 2,100 INA-1500 4F-345 and larger 25.0 1,500 2,330 *Two coils of any size or combination of sizes may be installed in 4F-1157 and larger 27 9,300 10,400 Series 4F-40 Standard Equipment Boiler: Water Trim: Jacket: The following trims are shipped loose for field mounting: 3 ½” theraltimeter (on models 4FW63 through 4FW675) or 5” thermometer and 6” pressure/altitude gauge (on models 4FW827 and larger) and loose ASME side outlet relief valve(s). The boilers are a three pass design constructed and stamped in accordance with ASME Section IV of the ASME Code for 15 psig steam or 30 psig water on any size boiler or 60 psig water on sizes 4FW63 through 4FW993. They are the sealed forced draft firing design with skid base and floor insulation. The flue outlet is a top outlet on sizes 4F63 through 4F345 and a rear outlet on sizes 4F450 and larger. Optional outlets are available on all sizes. The boiler comes complete with a gas tight front flue cleanout door, rear observation port on sizes 4F63 through 4F345, or rear access door and observation port on sizes 4F450 and larger and lifting lugs on sizes 4F127 and larger. Optional access doors and lifting lugs are available for all sizes. Rectangular type 1” fiberglass insulated jacket on sizes 4F63 through 4F345, 2” fiberglass insulated rectangular jacket on sizes 4F450 through 4F675 and 2” fiberglass wrap around jacket on sizes 4F827 and larger. Steam Trim: The following trim is shop mounted and wired: MM157 combination pump control and LWCO with alarm contacts and quick opening blowoff valves, probe type manual reset auxiliary LWCO, L404A operating pressuretrol, L404C manual reset high limit pressuretrol and appropriate firing rate control when required. The following trims are shop mounted and wired: probe type LWCO (on 30 psig models 4FW63 through 4FW675) or MM63M manual reset LWCO with quick opening blowoff valve (on 30 psig models 4FW827 and larger) or probe type LWCO (on 60 psi models 4FW63 through 4FW675) or MM150M manual reset LWCO with quick opening blowoff valve (on all 60 psi boilers on models 4FW827 and larger) or L4006A operating aquastat, L4006E manual reset high limit aquastat and appropriate firing rate control when required. Burner: As selected for the fuel to be burned, mounted and wired. Refer to burner data sheets for details of burner equipment. Burners available for gas, No. 2 oil, No. 4 oil, No. 5 oil, No. 6 oil, combination gas/No. 2 oil, gas/No. 4 oil, gas/No. 5 oil, gas/No. 6 oil, combination gas/No. 2 oil, gas/No. 4 oil, gas/No. 5 oil, and gas/No. 6 oil. The following trim is shipped loose for field mounting: 3 ½” steam pressure gauge (on models 4FL63 through 4F675), 6” steam pressure gauge (on models 4F827 and larger), ASME side outlet safety valve(s) and gauge glass set. © 2006 Burnham Commercial - Lancaster, PA Phone: 1-888-791-3790 www.burnhamcommercial.com 28 Series 4F-45 Forced Draft Firebox Generator Ratings and Data 4F - 45 Boiler Models 63 78 92 107 127 154 180 209 240 277 311 345 360A 450A 563A 675A Gross Output MBH BHP Lbs. Stm/Hr 469 14 483 579 17.3 597 683 20.4 704 797 23.8 821 944 28.2 973 1,145 34.2 1,180 1,339 40.0 1,380 1,553 46.4 1,601 1,784 53.3 1,839 2,062 61.6 2,125 2,313 69.1 2,384 2,568 76.7 2,646 2,678 80.0 2,760 3,348 100.0 3,450 4,251 127.0 4,380 5,055 151.0 5,210 364 1,515 449 1,870 530 2,210 618 2,575 733 3,055 889 3,705 1,039 4,340 1,205 5,020 1,384 5,765 1,600 6,665 1,795 7,480 1,993 8,305 2,078 2,598 3,299 3,923 8,660 10,825 13,745 16,345 Net Rating - Water MBH 403 504 594 693 821 996 1,165 1,351 1,552 1,794 2,012 2,234 2,350 2,913 3,698 4,398 Firing Rate - Gas MBH Firing Rate - Light Oil GPH Heavy Oil GPH 586 4.2 — 724 5.2 — 854 6.1 — 996 7.1 — 1,180 8.4 — 1,431 10.2 — 1,674 12.0 — 1,941 13.9 — 2,230 15.9 — 2,578 18.4 — 2,891 20.7 — 3,210 22.9 — 3,348 23.9 22.3 4,185 29.9 27.9 5,314 38.0 35.4 6,319 45.1 42.1 Heating Surface Sq. Ft. Fireside Waterside 59 63 73 78 86 92 101 107 120 127 145 154 168 180 194 209 224 240 257 277 289 311 320 345 360 398 450 497 563 622 675 746 Furnace Volume Cu. Ft. 8.8 10.7 12.6 14.6 18.3 21.9 25.3 29.1 34.7 39.7 44.4 49.1 58.9 68.0 89.3 104.7 Heat Release MBH/Cu. Ft. 66.6 67.7 67.8 68.2 64.5 65.3 66.2 66.7 64.3 64.9 65.1 65.4 56.8 61.5 59.5 60.4 65 90 81 112 94 132 110 153 133 168 145 196 172 232 198 268 214 288 245 329 274 369 302 408 470 569 551 666 663 801 788 951 Approx. Dry Weight Lbs. 1,700 1,900 2,100 2,600 2,700 3,100 3,300 3,600 4,200 4,600 5,300 5,600 6,900 8,700 Approx. Full Weight Lbs. Steam Water 2,240 2,450 2,570 2,835 3,090 3,195 3,510 3,870 3,800 4,095 4,300 4,735 4,730 5,235 5,250 5,830 5,980 6,595 6,435 7,140 7,575 8,365 8,110 10,615 13,290 14,825 16,970 8,995 11,495 14,255 15,975 18,325 Net Rating - Steam MBH Sq. Ft. Water Content Gal. Steam Water 9,300 10,400 360A-3 450-A 563A-3 675A-3 827 993 1157 1323 1654 1985 2315 Gross Output MBH BHP Lbs. Stm/Hr 2,953 88.2 3,044 3,445 102.9 3,550 4,188 125.1 4,316 4,924 147.1 5,075 6,126 183.0 6,315 7,388 220.7 7,617 8,606 257.1 8,872 9,842 294.0 10,146 12,302 367.5 12,682 14,766 441.1 15,223 17,220 514.4 17,753 Net Rating - Steam MBH Sq. Ft. 2,292 9,550 2,673 11,140 3,250 13,540 3,821 15,920 4,754 19,810 5,733 23,890 6,885 28,690 7,873 32,805 9,546 39,775 11,458 47,740 13,363 55,680 Net Rating - Water MBH 2,569 2,997 3,644 4,284 5,330 6,428 7,487 8,563 10,703 12,846 14,981 Firing Rate - Gas MBH Firing Rate - Light Oil GPH Heavy Oil GPH 3,691 26.4 24.6 4,306 30.8 28.7 5,235 37.4 34.9 6,155 44.0 41.0 7,658 54.7 51.0 9,235 66.0 61.6 10,758 76.8 71.7 12,303 87.9 82.0 15,378 110.0 102.7 18,458 132.0 123.2 21,525 154.0 143.7 Heating Surface Sq. Ft. Fireside Waterside 397 429 463 500 563 608 662 715 827 893 993 1,072 1,157 1,250 1,323 1,429 1,654 1,786 1,985 2,143 2,315 2,500 Furnace Volume Cu. Ft. 58.9 68.0 89.3 104.7 115.6 139.2 160.7 186.5 234.0 301.6 348.6 Heat Release MBH/Cu. Ft. 62.7 63.3 58.6 58.8 66.2 66.3 66.9 66.0 65.7 61.2 61.7 Water Content Gal. Steam Water 421 519 492 676 602 740 712 875 761 1,003 925 1,220 1,050 1,330 1,227 1,554 1,443 1,826 1,720 2,147 1,979 2,473 Approx. Dry Weight Lbs. 6,900 8,800 9,300 12,400 13,200 14,800 18,300 19,200 23,000 28,000 34,500 Approx. Full Weight Lbs. Steam Water 10,405 11,225 12,900 14,430 14,315 15,465 16,930 18,290 18,970 20,325 22,500 24,950 27,040 28,675 29,415 32,140 35,010 38,200 42,320 45,870 50,970 55,085 4F - 45 Boiler Models Ratings based on 4.5 square feet of heating surface per boiler horsepower 29 Series 4F Standard Equipment Boiler: The boilers are a three pass design constructed and stamped in accordance with ASME Section IV of the ASME Code for 15 psig steam or 30 psig water on any size boiler or 60 psig water on sizes 4FW63 through 4FW993. They are the sealed forced draft firing design with skid base and floor insulation. The flue outlet is a top outlet on sizes 4F63 through 4F345 and a rear outlet on sizes 4F450 and larger. Optional outlets are available on all sizes. The boiler comes complete with a gas tight front flue cleanout door, rear observation port on sizes 4F63 through 4F345, or rear access door and observation port on sizes 4F450 and larger and lifting lugs on sizes 4F127 and larger. Optional access doors and lifting lugs are available for all sizes. Jacket: Rectangular type 1” fiberglass insulated jacket on sizes 4F63 through 4F345, 2” fiberglass insulated rectangular jacket on sizes 4F450 through 4F675 and 2” fiberglass wrap around jacket on sizes 4F827 and larger. Steam Trim: The following trim is shop mounted and wired: MM157 combination pump control and LWCO with alarm contacts and quick opening blowoff valves, probe type manual reset auxiliary LWCO, L404A operating pressuretrol, L404C manual reset high limit pressuretrol and appropriate firing rate control when required. The following trim is shipped loose for field mounting: 3 ½” steam pressure gauge (on models 4FL63 through 4F675), 6” steam pressure gauge (on models 4F827 and larger), ASME side outlet safety valve(s) and gauge glass set. Water Trim: The following trims are shop mounted and wired: probe type LWCO (on 30 psig models 4FW63 through 4FW675) or MM63M manual reset LWCO with quick opening blowoff valve (on 30 psig models 4FW827 and larger) or probe type LWCO (on 60 psi models 4FW63 through 4FW675) or MM150M manual reset LWCO with quick opening blowoff valve (on all 60 psi boilers on models 4FW827 and larger) or L4006A operating aquastat, L4006E manual reset high limit aquastat and appropriate firing rate control when required. The following trims are shipped loose for field mounting: 3 ½” theraltimeter (on models 4FW63 through 4FW675) or 5” thermometer and 6” pressure/altitude gauge (on models 4FW827 and larger) and loose ASME side outlet relief valve(s). Burner: As selected for the fuel to be burned, mounted and wired. Refer to burner data sheets for details of burner equipment. Burners available for gas, No. 2 oil, No. 4 oil, No. 5 oil, No. 6 oil, combination gas/No. 2 oil, gas/No. 4 oil, gas/No. 5 oil, gas/No. 6 oil, combination gas/No. 2 oil, gas/No. 4 oil, gas/No. 5 oil, and gas/No. 6 oil. Instantaneous Hot Water Heating Coils *For Use in the Following Boiler Sizes Subject to Capacity Limitation of Boiler Coil Number Rated Capacity — Gallons Heated 40° to 140°F Boiler Water Temp. 108°F 180°F 212°F GPM GPH GPH INA-210 All sizes 3.5 210 325 INA-300 All except 4F-63 5.0 300 466 INA-360 All sizes 6.0 360 560 INA-450 All except 4F-63 7.5 450 700 INA-600 4F-154 and larger, also 4F-107 10.0 600 933 INA-750 4F-154 and larger, also 4F-107 12.5 750 1,165 INA-900 4F-92 and larger 15.0 900 1,400 INA-1125 4F-154 and larger 18.7 1,125 1,750 INA-1350 4F-277 and larger, also 4F-209 22.5 1,350 2,100 INA-1500 4F-345 and larger 25.0 1,500 2,330 *Two coils of any size or combination of sizes may be installed in 4F-1157 and larger © 2006 Burnham Commercial - Lancaster, PA Phone: 1-888-791-3790 www.burnhamcommercial.com 30 Series 4F-50 Forced Draft Firebox Generator Ratings and Data 63 78 92 107 127 154 180 209 240 277 311 345 360A 450A 563A 675A Gross Output MBH BHP Lbs. Stm/Hr 422 12.6 435 522 15.6 538 616 18.4 635 716 21.4 738 850 25.4 876 1,031 30.8 1,063 1,205 36.0 1,242 1,400 41.8 1,442 1,607 48.0 1,656 1,855 55.4 1,911 2,082 62.2 2,146 2,310 69.0 2,381 2,410 72.0 2,484 3,015 90.0 3,108 3,770 112.6 3,885 4,520 135.0 4,660 Net Rating - Steam MBH Sq. Ft. 327 1,365 405 1,690 478 1,990 556 2,315 660 2,750 800 3,335 935 3,895 1,086 4,525 1,247 5,195 1,439 5,995 1,616 6,735 1,793 7,470 1,870 7,790 2,340 2,926 3,508 9,750 12,190 14,615 Net Rating - Water MBH 367 454 536 623 740 897 1,048 1,218 1,398 1,614 1,811 2,010 2,097 2,623 3,280 3,932 Firing Rate - Gas MBH Firing Rate - Light Oil GPH Heavy Oil GPH 528 3.8 — 653 4.7 — 770 5.5 — 895 6.4 — 1,063 7.6 — 1,289 9.2 — 1,506 10.8 — 1,750 12.5 — 2,009 14.4 — 2,319 16.6 — 2,603 18.6 — 2,888 20.6 — 3,013 21.5 20.1 3,769 27.0 25.2 4,713 33.6 31.4 5,650 40.4 37.7 Heating Surface Sq. Ft. Fireside Waterside 59 63 73 78 86 92 101 107 120 127 145 154 168 180 194 209 224 240 257 277 289 311 320 345 360 398 450 497 563 622 675 746 Furnace Volume Cu. Ft. 8.8 10.7 12.6 14.6 18.3 21.9 25.3 29.1 34.7 39.7 44.4 49.1 58.9 68.0 89.3 104.7 Heat Release MBH/Cu. Ft. 60.0 61.0 61.1 61.3 58.1 58.8 59.5 60.1 57.9 58.4 58.6 58.8 51.2 55.4 52.8 53.9 65 90 81 112 94 132 110 153 133 168 145 196 172 232 198 268 214 288 245 329 274 369 302 408 470 569 537 666 683 801 788 951 Approx. Dry Weight Lbs. 1,700 1,900 2,100 2,600 2,700 3,100 3,300 3,600 4,200 4,400 5,300 5,600 6,700 8,700 Approx. Full Weight Lbs. Steam Water 2,240 2,450 2,570 2,835 3,090 3,195 3,510 3,870 3,800 4,095 4,300 4,735 4,730 5,235 5,250 5,830 5,980 6,595 6,435 7,140 7,575 8,365 8,110 10,615 13,290 14,825 16,970 8,995 11,495 14,255 15,975 18,325 4F - 50 Boiler Models 360A-3 450-A 563A-3 675A-3 827 993 1157 1323 1654 1985 2315 2645 3075 Gross Output MBH BHP Lbs. Stm/Hr 2,658 79.4 2,739 3,100 92.6 3,195 3,769 112.6 3,885 4,432 132.4 4,568 5,537 165.0 5,706 6,648 199.0 6,852 7,746 231.0 7,983 8,857 265.0 9,129 11,074 331.0 11,413 13,290 397.0 13,697 15,499 463.00 15,974 17,708 529.0 18,252 20,587 615.0 21,217 Net Rating - Steam MBH Sq. Ft. 2,063 8,596 2,406 10,025 2,925 12,188 3,439 14,329 4,299 17,910 5,161 21,505 6,014 25,060 6,877 28,655 8,598 35,825 10,318 42,995 12,033 50,140 13,748 57,285 15,976 66,525 Net Rating - Water MBH 2,312 2,697 3,279 3,856 4,817 5,784 6,739 7,706 9,634 11,562 13,484 15,406 17,911 Firing Rate - Gas MBH Firing Rate - Light Oil GPH Heavy Oil GPH 3,323 23.7 22.2 3,875 27.7 25.8 4,711 33.7 31.4 5,540 39.6 36.9 6,921 49.9 46.6 8,310 60.0 56.0 9,683 70.0 65.3 11,071 80.0 74.7 13,843 99.0 92.4 16,613 119.0 110.7 19,374 139.0 129.3 22,135 158.0 148.0 25,734 184.0 172.0 Heating Surface Sq. Ft. Fireside Waterside 397 429 463 500 563 608 662 715 827 893 993 1,072 1,157 1,250 1,323 1,429 1,654 1,786 1,985 2,143 2,315 2,500 2,645 2,857 3,075 3,321 Furnace Volume Cu. Ft. 58.9 68.0 89.3 104.7 115.6 139.2 160.7 186.5 234.0 301.6 348.6 383.8 505.6 Heat Release MBH/Cu. Ft. 56.4 57.0 52.8 52.9 59.9 59.7 60.3 59.4 59.2 55.1 55.6 63.5 50.9 Water Content Gal. Steam Water 421 519 492 676 602 740 712 875 761 1,003 925 1,220 1,050 1,330 1,227 1,554 1,443 1,826 1,720 2,147 1,979 2,473 2,173 2,718 2,814 3,665 Approx. Dry Weight Lbs. 6,900 8,800 11,000 12,400 14,800 18,300 19,200 19,800 23,000 28,000 34,500 38,200 49,000 Approx. Full Weight Lbs. Steam Water 10,450 11,225 12,900 14,430 14,315 15,465 16,930 18,290 18,970 20,325 22,500 24,950 27,040 29,375 29,415 32,140 35,010 38,200 42,320 45,870 50,970 55,085 56,290 60,820 72,430 79,510 4F - 50 Boiler Models Water Content Gal. Steam Water Ratings based on 5 square feet of heating surface per boiler horsepower 31 9,300 10,400 Series 4F Standard Equipment Boiler: The boilers are a three pass design constructed and stamped in accordance with ASME Section IV of the ASME Code for 15 psig steam or 30 psig water on any size boiler or 60 psig water on sizes 4FW63 through 4FW993. They are the sealed forced draft firing design with skid base and floor insulation. The flue outlet is a top outlet on sizes 4F63 through 4F345 and a rear outlet on sizes 4F450 and larger. Optional outlets are available on all sizes. The boiler comes complete with a gas tight front flue cleanout door, rear observation port on sizes 4F63 through 4F345, or rear access door and observation port on sizes 4F450 and larger and lifting lugs on sizes 4F127 and larger. Optional access doors and lifting lugs are available for all sizes. Jacket: Rectangular type 1” fiberglass insulated jacket on sizes 4F63 through 4F345, 2” fiberglass insulated rectangular jacket on sizes 4F450 through 4F675 and 2” fiberglass wrap around jacket on sizes 4F827 and larger. Steam Trim: The following trim is shop mounted and wired: MM157 combination pump control and LWCO with alarm contacts and quick opening blowoff valves, probe type manual reset auxiliary LWCO, L404A operating pressuretrol, L404C manual reset high limit pressuretrol and appropriate firing rate control when required. The following trim is shipped loose for field mounting: 3 ½” steam pressure gauge (on models 4FL63 through 4F675), 6” steam pressure gauge (on models 4F827 and larger), ASME side outlet safety valve(s) and gauge glass set. Water Trim: The following trims are shop mounted and wired: probe type LWCO (on 30 psig models 4FW63 through 4FW675) or MM63M manual reset LWCO with quick opening blowoff valve (on 30 psig models 4FW827 and larger) or probe type LWCO (on 60 psi models 4FW63 through 4FW675) or MM150M manual reset LWCO with quick opening blowoff valve (on all 60 psi boilers on models 4FW827 and larger) or L4006A operating aquastat, L4006E manual reset high limit aquastat and appropriate firing rate control when required. The following trims are shipped loose for field mounting: 3 ½” theraltimeter (on models 4FW63 through 4FW675) or 5” thermometer and 6” pressure/altitude gauge (on models 4FW827 and larger) and loose ASME side outlet relief valve(s). Burner: As selected for the fuel to be burned, mounted and wired. Refer to burner data sheets for details of burner equipment. Burners available for gas, No. 2 oil, No. 4 oil, No. 5 oil, No. 6 oil, combination gas/No. 2 oil, gas/No. 4 oil, gas/No. 5 oil, gas/No. 6 oil, combination gas/No. 2 oil, gas/No. 4 oil, gas/No. 5 oil, and gas/No. 6 oil. Instantaneous Hot Water Heating Coils Coil Number *For Use in the Following Boiler Sizes Subject to Capacity Limitation of Boiler Rated Capacity — Gallons Heated 40° to 140°F Boiler Water Temp. 108°F 180°F 212°F GPM GPH GPH INA-210 All sizes 3.5 210 325 INA-300 All except 4F-63 5.0 300 466 INA-360 All sizes 6.0 360 560 INA-450 All except 4F-63 7.5 450 700 INA-600 4F-154 and larger, also 4F-107 10.0 600 933 INA-750 4F-154 and larger, also 4F-107 12.5 750 1,165 INA-900 4F-92 and larger 15.0 900 1,400 INA-1125 4F-154 and larger 18.7 1,125 1,750 INA-1350 4F-277 and larger, also 4F-209 22.5 1,350 2,100 INA-1500 4F-345 and larger 25.0 1,500 2,330 *Two coils of any size or combination of sizes may be installed in 4F-1157 and larger © 2006 Burnham Commercial - Lancaster, PA Phone: 1-888-791-3790 www.burnhamcommercial.com 32 Series 4F Forced Draft Firetube Boiler “Ohio Special” Series 4F Ohio Special Boiler Features: • Three pass full wetback, packaged firetube type, constructed in accordance with requirements of the ASME Boiler and Pressure Vessel Code, Section IV for 15-psi steam. All units are registered with the National Board. • Sealed forced draft firing design. • Boiler tubes are expanded and flared. Separate second and third pass rear tube sheets allow safe expansion and contraction. • Waterback rear turnaround promotes rapid internal circulation and reduces gas temperatures at entrance to second pass, reducing tube and stress. • Easy opening, insulated front flue doors with bolted closure provide full access to all tubes. A 16-inch diameter bolted rear access door with observation port provides access to the boiler furnace. • Handhole washouts are provided for easy inspection and cleaning of waterside surfaces. • The round horizontal smoke outlet is standard. Vertical smokebox outlet and quadrant dampers are optional. • All steam boilers provided with a dry pan to ensure dry steam. • All boilers are provided with an enameled steel jacket over 2 inches of fiberglass insulation and lifting lugs. • The boiler is mounted on a heavy-duty steel base with extended skid and burner platform for protection of the burner during shipment and rigging. 33 Standard Trim and Controls • Steam pressure gauge — 3 ½ • 157 combination pump control • L404 operating pressuretrol • LWCO with alarm contacts • Gauge glass set • L404C manual reset high limit pressuretrol and appropriate firing rate control when required. Manual reset probe auxiliary LWCO. Dimensions (in Inches) Ratings and Data • quick opening blowoff valves 4F360-OS Boiler Model 4F360-OS Boiler Model 4F360-OS Gross Output MBH BHP Lb. Stm./Hr. 3,015 90.1 3,108 Net Rating - Steam MBH Sq. Ft. 2,340 9,750 107-1/2 Net Rating - Water MBH 2,623 F - Base Extension 26-3/4 Firing Rate G - Front Smoke Box Height 36-3/4 H - Front Smoke Box Depth 6-1/2 Gas - MBH Oil - GPH Light Oil (140,000 BTU/Gal.) Heavy Oil (150,000 BTU/Gal.) A - Boiler Width 52-1/4 B - Boiler Length 80-3/4 C - Boiler Height 82-3/8 D - Base Width 53-1/8 E - Base Length J - Supply Location 26 K - Supply Size - Flanged 8 L - Return Size - Threaded M - Return Location 4 7-3/8 N - Smoke Box Depth - Rear Vent 8 P - Vent Collar Diameter 14 Q - Rear Vent Collar Height R - Smoke Box Depth - Top Vent T - Top Vent Collar Height U - Tube Pull Space 3,769 — 26.9 25.1 Heating Surface - Sq. Ft. Fireside Waterside 358 396 Furnace Volume Cu. Ft. 58.9 Heat Release MBH/Cu. Ft. 64 Water Content - Gal. Steam Flooded 470 569 58-3/4 Approx. Dry Weight - Lbs. 16 Approx. Full Weight - Lbs. 66-1/4 6,710 Steam Flooded 10,615 11,495 81 V - Supply Fitting Height 3-1/2 W - Normal Water Line Height 69-1/4 34 © 2006 Burnham Commercial - Lancaster, PA Phone: 1-888-791-3790 www.burnhamcommercial.com Series 4N Natural Draft Firebox Boiler 35 Series 4N Natural Draft Firebox Boiler Ratings for Oil, Gas or Stoker Firing 4N Boiler Models 63 78 92 107 127 154 180 209 240 277 311 345 397 Gross Output MBH BHP Lbs.Stm./Hr. 245 7.3 253 299 8.9 308 348 10.4 359 403 12.0 415 522 15.6 538 626 18.7 645 724 21.6 746 870 26.0 897 996 29.8 1,027 1,142 34.1 1,177 1,278 38.2 1,317 1,414 42.2 1,457 21,60 65 2,226 Net Rating Steam MBH Sq. Ft. 190 790 232 970 270 1,125 313 1,305 405 1,690 486 2,025 562 2,340 675 2,815 773 3,220 887 3,695 992 4,235 1,098 4,570 1,667 6,990 Net Rating Water MBH 213 260 303 351 454 545 630 757 867 994 1,112 1,230 1,878 Firing Rate - Gas MBH Light Oil (140,000 BTU/Gal.) Heavy Oil (150,000 BTU/Gal.) 306 2.2 — 374 2.7 — 435 3.1 — 504 3.6 — 653 4.7 — 783 5.6 — 905 6.5 — 1,088 7.8 — 1,245 8.9 — 1,428 10.2 — 1,598 11.4 — 1,768 12.6 — 2,700 19.3 18.0 Coal (Stoker) Lbs./Hr. 25 31 36 41 54 64 74 89 102 117 131 145 222 Heating Surface Sq. Ft. Fireside Waterside 45 47 55 57 64 67 74 77 96 100 115 120 133 139 153 160 183 193 210 221 235 247 260 274 397 429 Furnace Volume Cu. Ft. * 8.8 10.7 12.6 14.6 18.3 21.9 25.3 29.1 34.7 39.7 44.4 49.1 58.9 Heat Release MBH/Cu. Ft. 34.8 35.0 34.5 34.5 35.7 35.8 35.8 37.4 35.9 36.0 36.0 36.0 45.8 67 92 83 114 96 134 113 156 133 168 149 200 171 231 197 267 209 283 239 323 267 362 295 401 421 520 1,500 1,700 1,900 2,200 2,500 2,800 3,100 3,400 3,900 4,300 4,900 5,200 6,500 Water 2,055 2,265 2,390 2,650 2,700 3,020 3,140 3,500 3,605 3,895 4,040 4,465 4,525 5,025 5,040 5,620 5,635 6,250 6,285 6,985 7,120 7,910 7,650 8,535 10,005 10,830 463 563 662 827 993 1157 1323 1654 1985 2315 2645 3075 Gross Output MBH BHP Lbs.Stm./Hr. 2,519 75 2,596 3,063 92 3,156 3,601 108 3,712 4,499 134 4,636 5,402 161 5,567 6,294 188 6,484 7,197 215 7,417 8,998 269 9,273 10,798 323 11,129 12,594 376 12,979 14,389 430 14,829 16,738 500 17,250 Net Rating Steam MBH Sq. Ft. 1,956 8,150 2,378 9,910 2,796 11,650 3,493 14,555 4,194 17,475 4,887 20,360 5,588 23,280 6,986 29,110 8,384 34,930 9,778 40,740 11,172 46,550 12,989 54,120 Net Rating Water MBH 2,190 2,663 3,131 3,912 4,697 5,473 6,258 7,824 9,390 10,951 12,512 14,554 3,149 22.5 21.0 3,829 27.3 25.5 4,501 32.1 30.0 5,624 40.2 37.5 6,753 48.2 45.0 7,868 56.2 52.5 8,996 64.3 60.0 11,248 80.3 75.0 13,498 96.4 90.0 15,743 112.5 104.9 17,986 128.5 120.0 20,923 149.5 139.5 Water Content Gals. Steam Water Approx. Dry Weight Lbs. Lbs. Approx. Weight FullSteam 4N Boiler Models Firing Rate - Gas MBH Light Oil (140,000 BTU/Gal.) Heavy Oil (150,000 BTU/Gal.) Coal (Stoker) Lbs./Hr. 258 314 369 461 554 646 738 923 1,108 1,292 1,476 1,717 Heating Surface Sq. Ft. Fireside Waterside 463 500 563 608 662 715 827 893 993 1,072 1,157 1,250 1,323 1,429 1,654 1,786 1,985 2,143 2,315 2,500 2,645 2,857 3,075 3,321 Furnace Volume Cu. Ft. * 68.0 89.3 104.7 115.6 139.2 160.7 186.5 234.0 301.6 348.6 383.8 505.6 Heat Release MBH/Cu. Ft. 46.3 42.9 43.0 48.7 48.5 49.0 48.2 48.1 44.8 45.2 46.9 41.4 492 607 602 740 712 875 761 1,003 925 1,220 1,050 1,330 1,227 1,554 1,443 1,826 1,720 2,147 1,979 2,473 2,173 2,718 2,814 3,665 Approx. Dry Weight Lbs. 8,000 8,500 10,100 12,300 13,300 16,600 18,600 21,700 26,500 32,800 37,500 48,200 Approx. Weight Full Lbs. Steam Water 12,100 13,055 13,515 14,665 16,030 17,390 18,630 20,645 21,005 23,455 25,340 27,675 28,815 31,540 33,710 36,900 40,815 44,370 49,270 53,385 55,590 60,120 71,630 78,710 Water Content Gals. Steam Water All models have 3 inch diameter tubes—except 3075 has 2-1/2 inch tubes * = deos not include base volume 36 Series 4N — Models 63 - 662 Dimensions (Inches) 4N Boiler Models A - Boiler Width B - Boiler Length 63 78 92 107 127 154 180 209 240 277 311 345 397 463 30-1/4 30-1/4 30-1/4 30-1/4 35-7/8 35-7/8 35-7/8 35-7/8 44-5/8 44-5/8 44-5/8 44-5/8 52-1/4 52-1/4 30 37 43-1/2 50-1/2 42-1/2 51 59 68 55 63 70-1/2 78 563 662 56 56 76-3/4 89-1/4 100-3/8 118-1/4 C - Boiler Height 52-1/8 52-1/8 52-1/8 52-1/8 60-1/2 60-1/2 60-1/2 60-1/2 67-1/2 67-1/2 67-1/2 67-1/2 79-1/4 79-1/4 82 82 D - Base Width 29-3/4 29-3/4 29-3/4 29-3/4 35-1/8 35-1/8 35-1/8 35-1/8 43-7/8 43-7/8 43-7/8 43-7/8 50-1/8 50-1/8 54 54 E - Base Length 30-1/2 37-1/2 *F - Base Height 15 15 44 51 43 15 15 18 51-1/2 59-1/2 68-1/2 55-1/2 63-1/2 18 18 18 18 18 71 18 78-1/2 78-1/8 90-5/8 101-3/4 119-5/8 18 18 18 18 18 G - Front Smoke Box Height 22-3/4 22-3/4 22-3/4 22-3/4 24-7/8 24-7/8 24-7/8 24-7/8 30-5/8 30-5/8 30-5/8 30-5/8 33-5/8 33-5/8 36-3/4 36-3/4 H - Front Smoke Box Depth 6-1/2 6-1/2 6-1/2 6-1/2 7-1/2 7-1/2 7-1/2 7-1/2 8-1/2 8-1/2 8-1/2 8-1/4 8-1/4 8-1/4 9-3/4 9-3/4 12 12 12 12 15 15 15 15 18 18 18 18 26 26 26 26 4 4 4 4 6 6 6 6 6 8 8 8 8 10 10 10 J - Supply Location **K - Supply Size L - Return Size 3 3 3 3 4 4 4 4 4 4 4 4 4 4 4 4 M - Return Location 3-1/2 3-1/2 3-1/2 3-1/2 4 4 4 4 4 4 4 4 4-3/8 4-3/8 4-3/8 4-3/8 N - Smoke Box Depth - Top Rear 8 8 8 8 9 9 9 9 10 10 10 10 16-1/2 16-1/2 16-1/2 16-1/2 20-1/2 20-1/2 20-1/2 20-1/2 22-1/2 22-1/2 22-1/2 22-1/2 16 16 16 16 16 16 16 16 20 24 26 28 P - Vent Collar Diameter Q - Rear Vent Collar Height 14 14 14 14 33-7/8 33-7/8 33-7/8 33-7/8 18 18 18 18 20 20 20 20 40 40 40 40 46 46 46 46 51-1/2 51-1/2 52-3/8 52-3/8 35-1/4 35-1/4 42-1/2 42-1/2 R - Smoke Box Collar Width Top Vent — — — — — — — — — — — — S - Smoke Box Collar Depth Top Vent — — — — — — — — — — — — 10 13 T - Top Vent Collar Height U - Tube Pull Space 41-7/8 41-7/8 41-7/8 41-7/8 49-1/8 49-1/8 49-1/8 49-1/8 57 57 57 57 64 64 61 70 57 65 72-1/2 80 81 94 105 23 3-3/8 3-3/8 3-3/8 3-3/8 3-3/8 3-3/8 3-3/8 3-1/2 3-1/2 3-5/8 3-5/8 55 55 55 55 69 69 39 45-1/2 52-1/2 44-1/2 V - Supply Fitting Height 1-5/8 1-5/8 W - Normal Water Line Height 40-3/4 40-3/4 40-3/4 40-3/4 48-1/2 48-1/2 48-1/2 48-1/2 1-5/8 *Oil, Gas, Stoker Only - See note below rating table for hand-fired boilers. **4” is IPS female thread, 6” and larger are flanged Specifications, dimensions data subject to change without notice. 3-3/8 13 53 32 1-5/8 12 37 66-3/16 66-3/16 66-7/8 66-7/8 4N — Models 827 - 3075 TheSeries Complete Boiler Room Supplier The Complete Boiler Room Supplier Dimensions (Inches) 4N Boiler Models 827 993 1157 1323 1654 1985 2315 2645 3075 A - Boiler Width 64 64 70 70 76 82 82 82 96 B - Boiler Length 106-1/4 129 116-1/2 136 130-1/2 128 148 162 163 *C - Boiler Height 91 91 102-1/2 102-1/2 118-1/8 138-1/8 138-1/8 138-1/8 148 D - Base Width 61-1/2 61-1/2 67-1/2 67-1/2 73-1/2 79-1/2 79-1/2 79-1/2 93-1/2 E - Base Length 107-1/4 130 117-1/2 137 131-1/2 129 149 164 164 F - Base Height 18 18 18 18 18 18 18 18 18 G - Front Smoke Box Door Height 29-5/16 29-5/16 35-7/16 35-7/16 40-3/8 52-1/8 52-1/8 52-1/8 65-7/8 H - Front Smoke Box Depth 12-3/4 12-3/4 13-3/4 13-3/4 14-3/4 15-3/4 15-3/4 15-3/4 16-1/2 J - Supply Location 22 22 22 22 22 22 22 22 68 **K - Supply Size 8 8 8 8 10 12 12 12 12 **L - Return Size - Steam 4 4 4 6 6 6 6 6 6 **L - Return Size - Water 6 6 6 8 8 8 8 8 8 M - Return Location N - Smoke Box Depth Rear P - Rear Vent Collar Diameter 6 6 6-7/8 6-7/8 6-7/8 7-1/4 7-1/4 7-1/4 7 20-3/4 20-3/4 22-3/4 22-3/4 22-3/4 24-3/4 24-3/4 24-3/4 26 28 32 32 35 38 44 44 44 46 71-1/2 71-1/2 81-1/2 81-1/2 94-5/8 110-5/8 110-5/8 110-5/8 119 R - Top Vent Collar Width 48 48 51 51 55 72 72 72 84 S - Top Vent Collar Depth 14 17 16 19 16 18 18 18 22 T - Top Vent Collar Height Q - Rear Vent Collar Height 87-3/4 87-3/4 99-1/4 99-1/4 113-7/8 132-7/8 132-7/8 132-7/8 142 U - Tube Pull Space 108 131 118-1/2 138 132-1/2 130 150 165 165 W - Normal Water Line Height 74 74 85-1/2 85-1/2 100-1/4 114-1/4 114-1/4 114-1/4 122-1/2 *Oil, Gas, Stoker Only - See note below rating table for hand-fired boilers. **4” is IPS female thread, 6” and larger are flanged Specifications, dimensions data subject to change without notice. 38 Series 4N Ratings • 15 psi steam, 30 psi water • Compact, efficient three-pass firebox design • Applications firing solid fuel, gas or oil • Ample firebox assures non-critical combustion, high efficiency Ratings for Hand Firing 4N Boiler Models 63 78 92 107 127 154 180 209 240 277 311 345 158 660 1,055 192 800 1,280 225 935 1,500 259 1,080 1,725 337 1,405 2,245 404 1,685 2,695 468 1,950 3,120 538 2,240 3,590 649 2,700 4,330 744 3,100 4,960 831 3,460 5,540 922 3,840 6,150 Fireside Waterside 45 47 55 57 64 67 74 77 96 100 115 120 133 139 153 160 183 193 210 221 235 247 260 274 Grate Area Sq. Ft. 4.0 5.1 6.1 7.2 7.2 8.8 10.3 12.0 12.6 12.6 13.4 14.5 Furnace Volume Cu. Ft. 8.8 10.7 12.6 14.6 18.3 21.9 25.3 29.1 34.7 39.7 44.4 49.1 Heat Release MBH/Cu. Ft. 39.9 40.1 39.2 39.2 40.5 41.0 41.1 42.9 41.2 41.3 41.0 41.0 Water Content - Gals. Steam Water 67 92 83 114 96 134 113 156 133 168 149 200 171 231 197 267 209 283 239 323 267 362 295 401 1,900 2,200 2,500 2,900 3,200 3,700 4,100 4,600 5,150 5,550 6,250 6,650 Steam Water 2,455 2,665 2,900 3,160 3,310 3,630 3,860 4,220 4,325 4,615 4,920 5,905 5,555 6,055 6,240 6,820 6,895 7,510 7,545 8,245 8,460 9,250 9,100 9,985 397 463 563 662 827 993 1157 1323 1654 1985 2315 2645 Net Rating - Steam or Water Net Rating - Steam Net Rating - Water MBH Sq. Ft. Sq. Ft. 1,408 5,865 9,391 1,724 7,185 11,500 2,188 9,115 14,595 2,572 10,715 17,155 3,214 13,390 21,435 3,859 16,080 25,740 4,496 18,730 29,990 5,141 21,420 34,290 6,427 26,780 42,870 7,713 32,135 51,445 8,996 37,485 60,005 10,278 42,825 68,555 Heating Surface - Sq. Ft. Fireside Waterside 397 429 463 500 563 608 662 715 827 893 993 1,072 1,157 1,250 1,323 1,429 1,654 1,786 1,985 2,143 2,315 2,500 2,645 2,857 Grate Area Sq. Ft. 16.4 18.1 20.5 22.5 25.6 28.4 30.9 33.2 37.4 41.2 44.7 48.0 Furnace Volume Cu. Ft. 58.9 68.0 89.3 104.7 115.6 139.2 160.7 186.5 234.0 301.6 348.6 383.8 Heat Release MBH/Cu. Ft. 52.3 53.0 49.1 49.2 55.6 55.5 56.0 55.1 55.0 51.2 51.6 53.6 Water Content - Gals. Steam Water 421 520 492 607 602 740 712 875 761 1,003 925 1,220 1,050 1,330 1,227 1,554 1,443 1,826 1,720 2,147 1,979 2,473 2,173 2,718 8,150 9,800 10,550 12,350 14,850 16,150 19,700 21,900 25,450 30,600 37,250 42,300 11,645 12,470 13,910 14,865 15,565 16,715 18,280 19,640 21,190 23,200 23,845 26,295 28,480 30,715 32,132 34,860 37,450 40,640 44,935 48,490 53,740 57,855 60,400 64,920 Net Rating - Steam or Water Net Rating - Steam Net Rating - Water MBH Sq. Ft. Sq. Ft. Heating Surface - Sq. Ft. Approx. Dry Weight - Lbs. Approx. Full Weight - Lbs. 4N Boiler Models Approx. Dry Weight - Lbs. Approx. Full Weight - Lbs. Steam Water Grates for hand firing are not supplied by Burnham Commercial Select boiler on net rating to match building heat loss or installed radiation. See additional note regarding heat value of coal on back page 39 Series 4NThe — Biomass/Wood Complete BoilerRatings Room Supplier Model 4NP-68 Gross Ratings Boiler Model MBH HP Steam Lbs./Hr. Firing Rate Lbs./Hr. Fireside Heating Surface Sq. Ft. Furnace Volume Cu. Ft. Water Content-Gallons Water Steam Dry Weight Lbs. 4NP625-68 3,077 92 3,171 653 625 148.5 941 764 16,211 4NP925-68 4,554 136 4,693 967 925 186.6 1,195 1,006 19,675 4NP1250-68 6,153 184 6,342 1,306 1,250 238.0 1,486 1,888 24,562 4NP1538-68 7,571 226 7,803 1,607 1,538 315.7 1,789 1,450 27,390 4NP1850-68 9,107 272 9,386 1,934 1,850 407.7 2,118 1,681 32,595 4NP2153-68 10,599 317 10,923 2,250 2,153 471.9 2,609 2,056 39,030 4NP2500-68 12,307 368 12,684 2,613 2,500 521.3 2,820 2,209 40,190 4NP3075-68 15,138 452 15,601 3,214 3,075 500.4 3,406 2,586 46,370 4NP3690-68 18,165 543 18,721 3,857 3,690 574.1 3,842 2,901 55,000 4NP4305-68 21,193 633 21,842 4,499 4,305 716.2 4,465 3,381 61,996 Model 4NL/W-68 Gross Ratings Boiler Model Firing Rate Lbs./Hr. Fireside Heating Surface Sq. Ft. MBH HP Steam Lbs./Hr. 4NL/W63-68 222 6.6 228 47 47 4NL/W78-68 271 8.1 279 57 55 Furnace Volume Cu. Ft. Water Content-Gallons Water Steam 8.8 2,265 2,055 10.7 2,650 2,390 4NL/W92-68 315 9.4 325 67 64 12.6 3,020 2,700 4NL/W107-68 364 10.9 375 77 74 14.6 3,500 3,140 4NL/W127-68 473 14.1 487 100 96 18.3 2,895 3,605 4NL/W154-68 566 16.9 583 120 115 21.9 4,465 4,040 4NL/W180-68 655 19.6 675 139 133 25.3 5,025 4,525 4NL/W209-68 753 22.5 776 160 153 29.1 5,620 5,040 4NL/W240-68 901 26.9 928 191 183 34.7 6,250 5,635 4NL/W277-68 1,034 30.9 1,065 219 210 39.7 6,985 6,285 4NL/W311-68 1,157 34.6 1,192 246 235 44.4 7,910 7,120 4NL/W345-68 1,280 38.2 1,319 272 260 49.1 8,535 7,650 4NL/W397-68 1,954 58.4 2,014 415 397 58.9 10,830 10,005 4NL/W463-68 2,279 68.1 2,349 484 463 68.0 13,055 12,100 4NL/W563-68 2,772 82.8 2,856 588 563 89.3 14,665 13,515 4NL/W662-68 3,259 97.4 3,359 692 662 104.7 17,390 16,030 4NL/W827-68 4,071 121.6 4,196 864 827 115.6 20,645 18,630 4NL/W993-68 4,888 146.0 5,038 1,038 993 139.2 23,455 21,005 4NL/W1157-68 5,696 170.1 5,870 1,209 1,157 160.7 27,675 25,340 4NL/W1323-68 6,513 194.6 6,712 1,383 1,323 186.5 31,540 28,815 4NL/W1654-68 8,142 243.2 8,392 1,729 1,654 234.0 36,900 33,710 4NL/W1985-68 9,772 291.9 10,071 2,075 1,985 301.6 44,370 40,815 4NL/W2315-68 11,396 340.4 11,745 2,420 2,315 348.6 53,385 49,270 4NL/W2645-68 13,021 389.0 13,419 2,764 2,645 383.8 60,120 55,590 4NL/W3075-68 10,215 305.1 10,528 2,169 2,075 505.6 78,710 71,630 NOTES: 1. Boiler model suffix “68” indicates 6.8 SQ.FT.F.S.H.S./HP 2. Firing rate based on biomass/wood fuel at 6000 BTU/LB and 78.5% operating efficiency 3. Furnace volume is measured from the bottom of the boiler mudleg 40 Series 4N Natural Draft Firebox Boiler Hand Fired Boilers — Rating Adjustment for Heating Value of Coal Jacket: Wrap-around type, with fiberglass insulation—installed. Hand fired ratings are based on coal having a heat value of 13,000 btu per pound. For coal of lesser heat value per pound, multiply the net load by the factor shown in the table before selecting boiler size: Heat Value of Coal - BTU/Lb. 12,500 12,000 11,500 11,000 10,500 10,000 9,500 9,000 Factor 1.04 1.08 1.13 1.18 1.24 1.30 1.37 1.44 Steam Trim: Steam pressure gauge (3-1/2 inch 63A through 662A; 6 inch 827 and larger), gauge glass set for mounting on boiler with 63A through 345A, cast iron water column with gauge glass set and tricocks 397A and larger, and ASME safety valve(s). Trim not installed. Water Trim: Theraltimeter (3-1/2 inch) 63A through 662A, pressure/altitude gauge (6 inch) and thermometer, (6 inch) 827 and larger, ASME relief vavle(s). Trim not installed. Additional Equipment Oil & Gas Fired Boilers - Burner opening in front head (base refractory or combustion equipment is not supplied by Burnham Commercial). Standard Equipment Boiler: Three-pass boiler constructed and stamped in accordance with Section IV of the ASME Boiler and Pressure Vessel Code for 15 psi steam and 30 psi water with separate base, rear smoke outlet (top outlet available when specified), gas tight front flue cleanout door, rear observation port 63A through 345A, rear access door with observation port 397A and larger, lifting lugs 127A and larger. Stoker Fired Boilers - Firedoor(s) in front head; hinged flue door, all sizes; ashpit door in base (Stoker not supplied by Burnham Commercial). Hand Fired Boilers - Same as stoker fired (Grate sets not supplied by Burnham Commercial). Instantaneous Hot Water Heating Coils Rated Capacity—Gallons Heated 40° to 140°F Boiler Water Temp. Coil Number *For Use in the Following Boiler Sizes Subject to Capacity Limitation of Boiler 108°F GPM 180°F GPH 212°F GPH INA-210 All sizes 3.5 210 325 INA-300 All except 4N-63A 5.0 300 466 INA-360 All sizes 6.0 360 560 INA-450 All except 4N-63A 7.5 450 700 INA-600 4N-154A and larger, also 4N-107A 10.0 600 933 INA-750 4N-154A and larger, also 4N-107A 12.5 750 1165 INA-900 4N-92A and larger 15.0 900 1400 INA-1125 4N-154A and larger 18.7 1125 1750 INA-1350 4N-277AS and larger, also 4N-209A 22.5 1350 2100 INA-1500 4N-345A and larger 25.0 1500 2330 *Two coils of any size or combination of sizes may be installed in 4N-1157 and larger 41 Series 4N Natural Draft Firebox Boiler Lancaster, PA 17601 Phone: 888-791-3790 www.burnhamcommercial.com 42 Series 4NP Natural Draft Firebox Boiler 4NP Boiler Models 625 925 1250 1538 A - Boiler Length 141 152 164 165 169 177 192 191 214 243 B - Boiler Supply Height 95 103 113 127 145 151 151 151 151 151 C - Base Length at Mudleg 125 136 142 143 143 151 166 161 184 213 D - Boiler Width at Mudleg 62 68 74 80 86 92 92 104 104 110 1850 2153 2500 3075 3690 4305 E - Firebox Width 48 54 60 66 72 78 78 90 90 96 F - Firebox Length 112 123 129 130 130 138 153 148 171 200 G - Firebox Height 40 42 46 54 66 66 66 54 54 54 H - Supply Location 65 71 75 75 77 79 87 86 98 112 J - Supply Nozzle Size (300lb. Flg.) 4 6 6 6 8 8 8 8 10 10 K - Return Connection Location 31-1/2 31-1/2 31-1/2 31-1/2 31-1/2 31-1/2 31-1/2 31-1/2 31-1/2 31-1/2 M - Return Connection Size 1-1/2 1-1/2 1-1/2 2 2 2-1/2 3 3 3 3 N - Front Smokebox Depth 10 10 12 12 14 14 14 16 16 16 P - Tube Removal Space 117 128 132 133 131 139 154 147 170 199 39 45 Q - Rear Flue Outlet Diameter 27 32 45 45 48 48 48 51 R - Base to Flue Centerline 67-3/4 73-1/4 81-15/16 91-5/8 109-9/16 112-9/16 112-9/16 107-7/16 107-7/16 107-7/16 S - Normal Water Line 92-5/16 104-1/4 76-1/2 83-7/8 121-1/4 125-13/16 125-13/16 122-3/8 122-3/8 122-3/8 AA - Width Over Columns 81 87 93 99 105 111 111 123 123 123 BB - Front and Rear Column Location 17 17 17 17 17 17 17 17 17 17 CC - Middle Column Location 46 54 54 55 55 61 69 64 78 85 Approximate Dry Weight (Lbs.) 16,211 19,675 24,562 27,390 32,595 39,030 40,190 46,370 55,000 61,996 Approximate Weight, Full (Lbs.) 22,575 28,055 34,458 39,469 46,598 56,156 58,591 67,911 79,165 90,160 All specifications, dimensions and data subject to change without notice. Dimensions shown are measured in inches. 43 The Complete Complete Boiler Boiler Room Room Supplier Supplier The Series 4NP GROSS RATINGS NET RATINGS MAX. FIRING RATE - SINGLE FUEL HEATING SURFACE SQ. FT. FURNACE VOLUME. CU. FT. WATER CONTENT GALLONS (STEAM) 148.5 764 BOILER MODEL MBH HP LBS. STM./ HR. STEAM MBH SQ. FT. STEAM GAS MBH #2 OIL GPH #6 OIL GPH #LBS/ HR. COAL* FIRE SIDE 4NP625-62 3,348 100 3,450 2,598 10,825 4,185 30.3 27.9 328* 625 4NP925-62 5,021 150 5,175 3,896 16,233 6,276 45.5 41.8 492* 925 186.6 1,006 4NP1250-62 6,695 200 6,900 5,195 21,646 8,369 60.6 55.8 656* 1,250 238.0 1,188 4NP1538-62 8,369 250 8,625 6,494 27,058 10,461 75.8 69.7 820* 1,538 315.7 1,450 4NP1850-62 10,043 300 10,350 7,793 32,471 12,554 91.0 83.7 984* 1,850 407.7 1,681 4NP2153-62 11,716 350 12,075 9,092 37,883 14,645 106.1 97.6 1148* 2,153 471.9 2,056 4NP2500-62 13,390 400 13,800 10,391 43,296 16,738 121.3 111.6 1312* 2,500 521.3 2,209 4NP3075-62 16,738 500 17,250 12,989 54,121 20,923 151.6 139.5 1,640* 3,075 500.42 2,586 4NP3690-62 20,085 600 20,700 15,586 64,942 25,106 181.9 167.4 1,968* 3,690 574.05 2,901 4NP4305-62 23,433 700 24,150 18,184 75,767 29,291 212.3 195.3 2,296* 4,305 716.22 3,381 4NP625-50 4,184 125 4,312 3,247 13,529 5,230 37.9 34.9 282** 625 148.5 764 4NP925-50 6,193 185 6,383 4,806 20,025 7,741 56.1 51.6 417** 925 186.6 1,006 4NP1250-50 8,369 250 8,625 6,494 27,058 10,461 75.8 69.7 563** 1,250 238.0 1,188 4NP1538-50 10,043 300 10,350 7,793 32,471 12,554 91.0 83.7 676** 1,538 315.7 1.450 4NP1850-50 12,386 370 12,765 9,612 40,050 15,483 112.2 103.2 834** 1,850 407.7 1,681 4NP2153-50 14,394 430 14,835 11,170 46,542 17,993 130.4 119.9 969** 2,153 471.9 2,056 4NP2500-50 16,738 500 17,250 12,989 54,121 20,923 151.6 139.5 1,127** 2,500 521.3 2,209 4NP3075-50 20,085 600 20,700 15,586 64,942 25,106 181.9 167.4 1,352** 3,075 500.42 2,586 4NP3690-50 23,433 700 24,150 18,184 75,767 29,291 212.3 195.3 1,577** 3,690 574.05 2,901 4NP4305-50 28,454 850 29,325 22,080 92,001 35,568 257.7 237.1 1915** 4,305 716.22 3,381 NOTES: 1. Boiler model suffix “62” indicates 6.15 sq. ft. F.S.H.S. /HP and “50” indicates 5 sq. ft. F.S.H.S./HP 2. Firing rate based on: Natural gas @ 1000 BTU/cu. ft. and 80% heat transfer efficiency #2 oil @ 138 MBH/gal. and 80% heat transfer efficiency #6 oil @ 150 MBH/gal. and 80% heat transfer efficiency * 100% coal input @ 13,000 BTU/pound and 78.5% heat transfer efficiency (6.15 rating) ** Coal input @ 13,000 BTU/pound limited to 70% of input in order to develop 5 sq. ft. rating. 3. Furnace volume is measured from the bottom of the boiler mud leg (no deduction for bridgewall) 4. Approximate dry weight includes H columns and base casing. Lancaster, PA 17601 888-791-3790 www.burnhamcommercial.com 44 C Series Compact Package Boiler 45 C Series Compact Packaged Boiler America’s Boiler Company FRONT REAR The Burnham Commercial C Series compact packaged boiler was designed using our 140+ years of boiler experience and is sold and serviced through the largest and most experienced network of sales representatives in the country. With a complete commercial product offering and unmatched sales and technical support, it’s no wonder why we are America’s Boiler Company! Packaged Boilers That Can Actually Fit Through A Door! The C Series Firetube boiler is fully packaged and designed to provide maximum cost and energy efficiency. The C Series boiler fits through any standard 36” x 80” doorway, eliminating the need for any costly building alterations or difficult site assemblies. This convenient size allows for easier and less expensive retrofit or upgrade of an existing boiler room. and extra heavy tube sheets assure the continued airtight conditions necessary for efficient combustion. Opening the front flue door allows convenient access to the firetubes. By brushing out all of the firetubes, the original efficiency of the boiler is restored in a matter of minutes. All tube ends are rolled in accordance with the ASME code and are inspected for hydraulic tightness by an independent insurance inspector, prior to shipping. These installation, operation and maintenance features add up to real savings for you. Factory testing assures you that the boiler will deliver clean, quiet and reliable heat from the day it’s installed. A forced-draft unit, the C Series avoids the expense of a tall stack and is much more economical to operate and install than atmospheric-fired boilers. The forced draft creates a more controlled combustion, and a more thorough mixture of fuel and air is acheived resulting in optimum efficiency. Other design features help maintain this durability and economy over the years. While the original efficiency of some other boilers can decrease when outer wrappers develop air leaks and tubes cannot be cleaned thoroughly, the C Series overcomes these problems. Built to ASME standards, its outer shell of heavy welded steel boilerplate 46 Efficiencies and Features C Series Anticipated Efficiencies NATURAL GAS 25% 50% 75% 100% Boiler HP 10 psig 180°F Water 10 psig 180°F Water 10 psig 180°F Water 10 psig 180°F Water 20 83.2 85.3 83.5 85.3 83.2 84.8 82.6 84.1 30 83.7 85.7 83.8 85.4 83.4 84.9 82.7 84.1 40 83.9 85.8 83.9 85.5 83.4 84.9 82.7 84.1 50 84.1 86.0 84.1 85.7 83.7 85.1 83.0 84.4 60 84.3 86.1 84.3 85.9 84.0 85.4 83.4 84.8 70 84.4 86.1 84.3 85.8 83.9 85.3 83.3 84.7 80 84.4 86.2 84.3 85.9 83.9 85.4 83.3 84.7 90 84.6 86.3 84.6 86.1 84.3 85.7 83.8 85.2 100 84.7 86.4 84.8 86.3 84.6 86.0 84.2 85.6 #2 OIL 25% 50% 75% 100% Boiler HP 10 psig 180°F Water 10 psig 180°F Water 10 psig 180°F Water 10 psig 180°F Water 20 86.0 88.2 86.2 87.9 86.0 87.5 85.4 86.9 30 86.7 88.6 86.7 88.3 86.4 87.8 85.8 87.2 40 86.8 88.7 86.8 88.3 86.4 87.9 85.9 87.3 50 87.2 89.0 87.1 88.6 86.8 88.2 86.3 87.7 60 87.4 89.2 87.4 88.9 87.1 88.6 86.7 88.1 70 87.5 89.2 87.3 88.9 87.1 88.5 86.6 88.0 80 87.5 89.3 87.4 88.9 87.1 88.5 86.7 88.0 90 87.8 89.5 87.8 89.3 87.6 89.0 87.2 88.6 100 88.0 89.7 88.0 89.6 87.9 89.3 87.6 89.0 C Series Features Boiler: an enameled steel jacket installed over fiberglass insulation. The boiler is mounted on a heavy-duty structural steel base with extended skid and burner platform for protection of the burner during shipment and rigging. Three-pass firetube type, constructed with heavy steel, in accordance with requirements of the ASME Code. All units are registered with the National Board. Water cooled sidewalls in the rear turnaround promote rapid internal circulation and reduce gas temperatures at the entrance to the second pass, reducing tube end stress. All tube ends are rolled and flared. Standard Trim and Controls: Steam: 157 pump control/low water cut-off with alarm con- tacts—piped with quick opening blowoff valve. Gauge glass set with hand-operated gauge and try cocks. Steam pressure gauge—4 ½-inch dial. L404A operating pressuretrol, L404C manual reset high limit pressuretrol and appropriate firing rate control when required. Manual reset probe auxiliary low water cut-off. ASME side outlet safety valve(s). Easy-opening insulated front and rear flue doors with light weight non-refractory closure provide full access to all tubes. No elaborate seals are used. The C Series oversized furnace easily accommodates any burner. Washouts are provided for easy inspection and cleaning of waterside surfaces. All steam boilers are provided with a dry pan to ensure dry steam. A feedwater diffuser is provided on steam boilers. All water boilers are equipped with a dip tube at supply outlet and diffuser at return inlet. The round vertical smoke outlet has room for an optional quadrant damper. All boilers are provided with lifting holes and 47 Water: 63M manual reset low water cut-off—piped with quick opening blowoff valve. Combination pressure/temperature gauge—3 ½ inch dial. L4006A operating aquastat and L4006E manual reset high limit aquastat and appropriate firing rate control when required. ASME side outlet relief valve(s). C-Series Ratings & Dimensions C Series Ratings BHP A B C Gross Output MBH Gross Output Lbs/Hr Net Rating Water MBH Net Rating Steam MBH Sq Ft Net Steam Firing Rate MBH - Gas Firing Rate GPH #2 Oil 20 30 66-3/8 75-5/8 670 690 582 520 2,166 816 5.7 30 30 66-3/8 82-5/8 1,004 1,035 873 780 3,249 1,225 8.5 40 34-1/2 73-7/8 90-1/8 1,339 1,380 1,164 1,040 4,332 1,633 11.4 50 34-1/2 75-3/8 100-5/8 1,674 1,725 1,455 1,299 5,415 2,041 14.2 60 34-1/2 75-3/8 113-1/8 2,009 2,070 1,747 1,559 6,497 2,449 17.1 70 34-1/2 78-1/2 114-5/8 2,009 2,415 2,038 1,819 7,580 2,858 19.9 80 34-1/2 78-1/2 125-1/8 2,678 2,760 2,329 2,079 8,663 3,266 22.8 90 34-1/2 78-1/2 135-1/8 3,013 3,105 2,620 2,339 9,746 3,674 25.6 100 34-1/2 78-1/2 145-1/8 3,348 3,450 2,911 2,599 10,829 4,082 28.5 C A OVER SKID OVERALL WIDTH PLAN VIEW B MAX. HEIGHT FRONT VIEW SIDE VIEW ©2005 Burnham Commercial Lancaster, PA 17603 Phone: 888-791-3790 www.burnhamcommercial.com 48 Component Summary Information A boiler is not only a significant plant expenditure, but it is the most important element of any mechanical heating/process system. The continued reliability of the boiler is heavily dependent upon the quality and chemistry of the water within the system. Burnham Commercial features a complete line of boiler room accessory products designed to match the performance needs of your Burnham Commercial boiler. Proper use and installation of this equipment can significantly improve system efficiency and boiler longevity. Burnham Deaerator Systems are designed to protect your Burnham boiler and steam system from the corrosion caused by the presence of non-condensable gases. A solution of oxygen in water is very corrosive to metals widely used in stem systems. Use of deaerator systems pay for themselves in fewer downtime hours, less chemical additives and reduced maintenance to the entire steam system. Burnham Water Softener Systems are designed to produce conditioned water to reduce the minerals which produce detrimental scale formation on the heat transfer surfaces in the boiler. Use of a water softener reduces the need for other chemical scale control additives. Burnham Chemical Feed Systems enable treatment of boiler feedwater with chemicals that protect against boiler scaling and corrosion. Amount and type of chemical treatment will vary depending upon the individual application. Burnham Boiler Feedwater Systems are designed to efficiently store and return hot condensate in combination with make-up water to automatically meet boiler water demands. Use of boiler feedwater systems can account for significant fuel savings and lower total chemical treatment costs. Burnham Condensate Return Systems are complete systems designed to increase the energy/water saving circuit for steam heating or process systems and minimize difficulties from boiler encrustation by recycling previously-treated system water. Burnham Blow Down Systems are designed to eliminate mineral build-up from dissolved solids that would cause scale and boiler corrosion. They are available in two basic types: Bottom Blow Down designed for forceful removal of bottom residue and Surface Blow Down/Heat Recovery which is an ongoing process that removes dissolved solids from the top level of water in the boiler while providing a heat recovery function as well. 49 Typical Steam System Layout Condensate Return System Water Softener System Boiler Feedwater System Boiler Surge System Surface Blow Down/Heat Recovery System Chemical Feed System Deaerator System Bottom Blow Down 50 Boiler Accessories 51 Chemical Feed System Continuous Run & On-Off Boiler Feedwater Pump Applications • Equipment to dose chemicals to treat boiler feedwater. • Introduces chemicals to the boiler or boiler feedwater piping. • Vertical 50 gallon polyethylene tank on stand with lid (other size tanks and tank materials available). • 5/8” piston pump, adjustable from 0 to 6.2 gallons per hour (GPH) (other size and capacity of piston and diaphragm pumps available). • Piston pump to 1000 psig (various stainless steel heads available as an option). • Modular configuration to meet customer requirements includes: tank with lid on stand, piston pump, factor suction piping and agitator Continuous Run only: control panel and make-up water meter. • Can be custom configured to meet customer • Agitator: angle or clamp mounted, 1/4 HP TENV, requirements. 115/1/60 volt motor standard (50 hertz and many other motor options available). • More than one pump may be mounted under a • Pump control via make-up water meter signal to 50 gallon tank. • 1/4 HP, totally enclosed non-ventilated (TENV), 115/1/60 volt motor standard (50 hertz and many other motor options available). • Factory suction piping includes: strainer and safety relief valve. panel-mounted timer. • Continuous Run - NEMA 12 control panel includes: mixer and pump switches, motor relays, fuses, terminal strip and timer. • On-Off - Control panel and water meter available as options. 52 Chemical Feed System (Continuous Run & On-off Boiler Feedwater Pump Applications) Specifications Dimensions Capacity in Gallons Wall A B C D Part Number Tank and Lid only 30 1/8” 18 30 12 49 103 030 55 1/8” 22 34 17 60 305 050 100 1/4” 28 42 18 70 310 0100 150 1/4” 31 47 18 75 315 0150 200 1/4” 36 48 20 77 320 0200 275 1/4” 42 48 20 77 327 0275 360 1/4” 48 48 20 77 336 0360 500 5/16” 54 60 20 89 350 0500 © 2006 Burnham Commercial - Lancaster, PA Phone: 1-888-791-3790 www.burnhamcommercial.com 53 Bypass and Shot Feed Systems For applications requiring bulk feeding of chemicals to a pressure system Bypass Chemical Feeders • Bypass chemical feeders include: tank, gauge glass, control and sample valves and funnel. Shot Feeders funnel. • Used in applications where a continuous supply of chemical is needed in a closed loop or low makeup system. • Flow adjustments of chemicals are made manually with the flow regulator. • Shot feeders include: tank, sample valve and • Used to add a slug of chemicals into a low makeup or closed loop systems. • Shot feeders are constructed of steel and have a rated working pressure of 125 psig. 54 Bypass and Shot Feed Systems Bypass Feeder Item Description Qty. 1 Tank 1 2 Funnel 1 3 Petcocks 2 4 1” Pipe Nipple 2 5 1” Valve 2 6 Gauge Valve 2 7 Sight Glass 1 8 Glass Guards 9 1” x 3/8” Reducer Bushing Dimensions in Inches Tank Size (gallons) A (Dia.) B (Lht.) 2 1 6 10 1 1-1/2 6 12 10 3’8” Pipe Nipple 3 2 8 10 11 3’8” Union 1 2-1/2 8 12 12 Flow Control Valve 1 5 10 15 13 3/8” valve 1 10 10 29 14 32 18 28 14 1/2” Coupling 3 18 15 1” Coupling 2 25 NOTE: 5 gallon and larger feeders have 12" legs. All dimensions are approximate 3/4 Gallon Item Description Qty. 1 Tank 1 2 Funnel 1 3 1/2” Pipe Nipple 4 4 1” x 1/2” Reducer Bushing 1 5 Petcocks 2 6 1/2” Valve 2 7 1/2” Tee 1 8 1/2” Coupling 4 1 - 25 Gallon Dimensions in Inches Item Tank Size (gallons) A (Dia.) B (Lht.) 1 6 10 1-1/2 6 12 2 8 10 2-1/2 8 12 5 10 15 10 10 29 18 14 32 25 18 28 NOTE: 1. All dimensions are approximate 2. All dimensions are in inches 55 Description Qty. 1 Tank 1 2 Funnel 1 3 1” Pipe Nipple 3 4 Petcocks 2 5 1” Valve 2 6 1/2” Coupling 3 7 1” Coupling 2 © 2006 Burnham Commercial - Lancaster, PA Phone: 1-888-791-3790 www.burnhamcommercial.com Boiler Feedwater Systems Boiler Feedwater System Features • Complete system including: vessel, pump(s), stand, trim, and control panel BHFS • Acts as a reservoir for condensate return, make-up water, and boiler feedwater • Horizontal, stand-mounted, atmospheric configuration. Vessel unbolts from stand for ease of replacement and installations • Dished head, factory pressure tested, non-code stamped vessel–standard. ASME, Section VIII Code stamped vessels, corrosion resistant vessels available • Model range: 43 gallon through 1,285 gallon BHTS • Water storage to full overflow: 15 minutes • Factory piped pump re-circulation • Oversize pump suction lines • Additional opening for future applications • Auxiliary relief vent(s) • Can be custom configured to meet customer requirements • Factory insulation and jacketing available • Option to pre-heat boiler feedwater 56 Condensate Return System Condensate Return System Features • Many motor and voltage options available. • Many trim, electrical and control panel options available. • Modular configuration to meet customer requirements includes: tank, pump(s), float control/alternator, control panel and trim options. • Pump options: - 1750 RPM - 1/4 HP/1.5 GPM at 1 0 psig through 3 HP/75 GPM at 20 psig - 345 0 RPM - 1/3 HP/1.5 GPM at 1 0 psig through 10 HP/150 GPM at 60 psig • Inexpensive/efficient mechanism for the capture and return of condensed steam. Units may be converted to act as a small boiler feedwater units. • “NO OPTION/QUICK SHIP” units available (15 to 21 gallon cast iron tank, 10 and 16 gallon steel tank, simplex or duplex, single phase with float switch, NO ALTERNATOR; 6 gallon cast iron • Available in either rectangular steel tank (16-20 gallon) or rectangular cast iron tank (15-110 gallon). 57 Blowdown Heat Recovery System Flash Economizer • Reduces dissolved solids from the top level of water in the boiler. • Recovers heat from surface blowdown to heat boiler feed or make-up water. • ASME Section VIII code-stamped flash separator and coil. • Separator is sized to accommodate a given percent surface blowdown/flow rate from boiler operating pressure to a given vent psig. • Coil is sized to accommodate make-up flow rate at between 8 and 18 psig pressure drop. • Model Range: HR-39 (3 GPM blowdown/9 GPM make-up) through HR-30150 (30 GPM blowdown/150 GPM make-up). • Complete system configured to include: flash separator mounted above and flanged to a stainless steel or copper coil on stainless steel stand with trap, ball valve, gauge glass, safety valve, 3 thermometers and factory piping. • Stainless steel striking plate standard. • Openings to facilitate cleaning and inspection standard. • Options include multiple boiler manifold and mounting of conductivity controller. • Flash separator flanged to coil section for ease or removal for cleaning. 58 Blowdown Heat Recovery System (Flash Economizer) Specifications Model Blowdown Capacity GPM Make-up Capacity GPM Pressure Drop* A B C D E F G H HR-39 3 9 9 psi 97 50 36 10 1 2-1/2 1 1 HR-315 3 15 9 psi 96 44 44-1/4 8 1 2-1/2 1 3/4 HR-612 6 12 8 psi 111 53 46 12 1-1/2 3 1 1-1/4 HR-630 6 30 10 psi 110 49 50 10 1-1/2 3 1 3/4 HR-1020 10 20 13 psi 106 50 44 16 1-1/2 4 2 1-1/2 HR-1050 10 50 10 psi 100 44 42 16 1-1/2 4 2 1-1/4 HR-2040 20 40 18 psi 140 67 62 18 1-1/2 6 2 2 HR-20100 20 100 10 psi 140 67 62 18 1-1/2 6 2 1-1/2 HR-3060 30 60 15 psi 172 76 85 18 1-1/2 6-8 2 1-1/2 HR-30150 30 150 18 psi 132-1/2 67 53-1/4 24 1-1/2 6-8 2 2-1/2 * Across water coil at maximum flow Constructed in accordance with ASME Code, Secion VIII, Division 1, for MAWP of 150 PSIG. Hydrostatic tested at 225 PSIG. Safety Relief Valve set at 150 PSIG. © 2006 Burnham Commercial - Lancaster, PA Phone: 1-888-791-3790 www.burnhamcommercial.com 59 Bottom Blowdown Tank • Eliminate precipitated solids from the bottom of the boiler. • Cools blowdown to 140°F or below before dumping to drain by storing one entire blowdown in a reservoir and using it to cool the next blowdown. • ASME Section VIII code-stamped tank. • Sized either to accommodate one complete boiler blowdown or to satisfy New Jersey regulations. • Model Range: 18” diameter x 24” height through 72” diameter x 92” height • Modular configuration to meet customer requirements includes: tank, legs, gauge glass and pressure gauge. • Can be custom configured to meet customer requirements. • Stainless steel striking plate standard. • Openings to facilitate cleaning and inspection standard. • Safety valve and thermometer may be included as options. 60 • General - All Blowdown Tanks, whether of the closed or vented type should be of the following dimensions in relation to the boiler rating, and must have approved openings for cleaning and inspections: Boiler Blow-off Pressure Line Pipe Vent Pipe Outlet Diameter PSIG Size Size Pipe Size of Tank New Jersey Regulations for Blowdown Tanks 100 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 2-1/2” 3” 3-1/2” 4” 5” 6” 3” 3” 4” 5” 6” 6” 20” 24” 30” 42” 48” 54” 3’6” 4’0” 4’2” 4’0” 4’6” 6’0” 150 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 3” 3-1/2” 4” 5” 6” 8” 3 3-1/2” 4” 5” 6” 8” 20” 24” 36” 42” 54” 60” 3’6” 5’0” 5’0” 5’0” 5’6” 6’0” 200 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 3” 4” 5” 6” 8” 8” 3” 4” 5” 6” 8” 8” 20” 30” 36” 42” 48” 60” 4’3” 4’6” 5’0” 6’0” 7’3” 7’0” 250 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 3-1/2” 4” 5” 6” 8” 10” 3” 4” 5” 6” 8” 10” 24” 30” 42” 48” 54” 60” 4’0” 4’6” 4’6” 5’0” 7’0” 7’2” 300 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 3-1/2” 5” 6” 8” 8” 10” 3-1/2” 5” 6” 8” 8” 10” 24” 30” 42” 48” 60” 66” 4’6” 5’6” 5’0” 5’6” 6’3” 7’8” 350 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 4” 5” 6” 8” 10” 10” 4” 5” 6” 8” 8” 10” 24” 30” 42” 48” 60” 72” 5’0” 5’6” 5’6” 6’2” 6’10” 7’0” 400 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 4” 5” 6” 8” 10” 10” 4” 5” 6” 8” 8” 10” 24” 30” 42” 48” 66” 72” 5’6” 6’0” 6’0” 6’4” 6’0” 8’0” • Closed or Pressure Type - A Blowdown Tank subjected to the maximum steam boiler pressure must be constructed for such pressure and stamped with either New Jersey, National Board or ASME Standard. • When the blowdown from any steam boiler is disposed in a sewer or other interconnected system, a Blowdown Tank must be placed between the boiler and the sewer or system. • The minimum metal thickness of Blowdown Tanks, whether pressure or atmospheric, must not be less than 5/16”. • Atmospheric or Vented Type - The outlet from the Blowdown Tank shall be twice the area of the boiler blowdown pipe and made to extend internally within 6” from the bottom of the tank. • A vent pipe, at least twice the diameter to the inlet, shall lead to the outside atmosphere. • Vents shall be as direct as possible to the outside of the atmosphere and discharge at a point not less than seven feet above the adjacent walkway or areas without a valve or other possible obstruction such as a water pocket. © 2006 Burnham Commercial - Lancaster, PA Phone: 1-888-791-3790 www.burnhamcommercial.com 61 Height of Tank Boiler Rating HP Cu. Ft. Minimum Size Tank Gallons 2 - 20 3.5 18” diameter x 24” 26.4 21 - 50 7.7 24” diameter x 30” 59 51 - 100 14.7 30” diameter x 36” 110 101 - 200 21.6 36” diameter x 36” 160 201 - 400 24.8 36” diameter x 42” 185 401 - 800 39.5 42” diameter x 48” 288 801 - 1000 63.0 48” diameter x 60” 470 Flash Separator • Reduces steam pressure or vents process steam directly to atmosphere. • Eliminates moisture from process steam (cyclonic spinning mechanism permits the use of smaller tanks to completely separate flash steam from condensate). • ASME Section VIII “UE” stamped separator standard up to model BFS-16-56. • ASME Section VIII “U” stamped separator standard for models BFS-16-56 and above. • Sized to accommodate a given #/hour flow rate of steam from a given source psig to a given vent psig. • Model Range: 6” diameter x 34” high through 36” diameter x 108” high. • Modular configuration to meet customer requirements includes a flash separator and the following options: trap, check valve, ball valve, safety relief valve and gauge glass. • Can be custom configured to meet customer requirements. • Stainless steel striking plate standard. 62 Pressure From... Pressure To... 700 600 500 400 300 200 100 50 30 15 7 0.0 800 2.5 5.2 7.9 10.8 14.1 18.0 23.1 26.9 29.0 31.1 32.6 34.3 700 600 500 400 300 200 100 75 50 25 2.7 5.5 8.5 11.9 15.8 21.0 24.9 27.0 29.2 30.7 32.4 2.9 6.0 9.4 13.5 18.8 22.7 24.9 27.1 28.6 30.4 3.2 6.7 10.9 16.3 20.4 22.6 24.8 26.4 28.2 3.7 7.9 13.5 17.6 19.9 22.2 23.8 25.6 4.4 10.2 14.4 16.7 19.0 20.7 22.5 6.0 10.4 12.8 15.2 16.9 18.7 4.6 7.1 9.6 11.3 13.3 2.5 5.1 7.6 9.4 11.9 2.6 5.2 7.0 9.0 1.8 3.7 5.8 Follow the “Pressure From...” down vertically on the chart at left to the “Pressure To...”. Example: 75 PSIG condensate flashed to low pressure heating system at 15 PSIG gives 7.6% condensate flashed into system. After determining the percent of flash from the chart above, determine the size of Flash Separator from the chart below. Example: Referring back to the chart above, you have a 7.6% flash, If you have 30,000 #/hour condensate at 75PSIG, 2,280 #/hour steam (30,000 x .076). Locate 30,000 in the left column below, go across to 2,280 #/hour flash steam column (3,000). You would use a 56” high x 18” diameter Flash Separator with a 3” draft and 5” vent. #/Hour Condensate 100,000 90,000 80,000 70,000 60,000 50,000 40,000 30,000 20,000 10,000 5,000 3,000 2,000 1,000 500 Height Diameter Drain Vent Height Diameter Drain Vent Height Diameter Drain Vent Height Diameter Drain Vent Height Diameter Drain Vent Height Diameter Drain Vent Height Diameter Drain Vent Height Diameter Drain Vent Height Diameter Drain Vent Height Diameter Drain Vent Height Diameter Drain Vent Height Diameter Drain Vent Height Diameter Drain Vent Height Diameter Drain Vent Height Diameter Drain Vent 100 108 30 5 2 96 30 5 2 96 24 5 2 72 24 4 2 56 24 4 2 72 20 4 2 56 20 4 2 56 18 3 2 56 14 2-1/2 2 34 14 2 2 34 10 1-1/2 2 34 10 1-1/4 2 34 8 1-1/4 2 34 6 1 2 34 6 1 2 500 108 30 5 2 96 30 5 2 96 24 5 2 72 24 4 2 56 24 4 2 72 20 4 2 56 20 4 2 56 18 3 2 56 14 2-1/2 2 34 14 2 2 34 10 1-1/2 2 34 10 1-1/4 2 34 8 1-1/4 2 34 8 1 2 34 6 1 2 700 108 30 5 2-1/2 96 30 5 2-1/2 96 24 5 2-1/2 72 24 4 2-1/2 56 24 4 2-1/2 72 20 4 2-1/2 56 20 4 2-1/2 56 18 3 2-1/2 56 14 2-1/2 2-1/2 34 14 2 2-1/2 34 10 1-1/2 2-1/2 34 10 1-1/4 2-1/2 34 8 1 2-1/2 34 8 1 2-1/2 1,000 108 30 5 3 96 30 5 3 96 24 5 3 72 24 4 3 56 24 4 3 72 20 4 3 56 20 4 3 56 18 3 3 56 16 2-1/2 3 34 14 2 3 34 10 1-1/2 3 34 10 1-1/4 3 34 10 1 3 2,000 108 30 54 4 96 30 5 4 96 24 5 4 72 24 4 4 56 24 4 4 72 20 4 4 56 20 4 4 56 18 3 4 56 16 2-1/2 4 34 14 2 4 34 14 1-1/2 4 34 14 1-1/4 4 3,000 108 30 5 5 96 30 5 5 96 24 5 5 72 24 4 5 56 24 4 5 72 20 4 5 56 20 4 5 56 18 3 5 56 16 2-1/2 5 34 14 2 5 34 14 1-1/2 5 #/Hour Flash Steam 4,000 8,000 108 108 30 30 5 5 6 8 96 96 30 30 5 5 6 8 96 96 24 24 5 5 6 8 72 72 24 24 4 4 6 8 56 56 24 24 4 4 6 8 72 72 20 20 4 4 6 8 56 56 20 20 4 4 6 8 56 56 18 18 3 3 6 8 56 56 16 16 2-1/2 2-1/2 6 8 34 34 14 16 2 1-1/2 6 8 34 14 1-1/4 6 12,000 108 30 50 10 96 30 5 10 96 24 4 10 72 24 4 10 56 24 4 10 72 20 4 10 56 20 3 10 56 20 3 10 56 20 2 10 18,000 108 30 5 12 96 30 5 12 96 24 4 12 72 24 4 12 56 24 4 12 72 24 4 12 56 24 3 12 56 24 2-1/2 12 21,000 108 30 5 14 96 30 4 14 96 30 4 14 72 30 4 14 56 30 4 14 72 30 3 14 56 30 3 14 25,000 108 36 5 16 96 36 4 16 96 36 4 16 72 36 4 16 56 36 4 16 72 36 3 16 35,000 108 36 4 18 96 36 4 18 96 36 4 18 72 36 4 18 *Flash Separators over 18” diameter, cleanout will be 2” NPT coupling. Dimension Chart Model BFS Inlet - Specify inlet to match your return line or blowoff line I 34 56 72 96 108 H 6 8 10 14 16 18 20 24 30 36 Dia. 1 1-1/4 1-1/2 2 2-1/2 3 4 5 D 2 2-1/2 3 4 5 6 8 10 12 14 V PL 5/16 3/8 © 2006 Burnham Commercial - Lancaster, PA Phone: 1-888-791-3790 www.burnhamcommercial.com 63 16 18 Bottom Blowdown Separator • Eliminate precipitated solids from the bottom of the boiler. • Cools blowdown to 140°F or below before dumping to drain by introducing cooling water via an aftercooler. • ASME Section VIII “UE” stamped separator. (“U” stamp available as option) • Sized to accommodate flow based on boiler blowdown line size and boiler operating pressure. • Model Range: 14” diameter x 22” through 56” in height for standard boilers (10” diameter x 14” high option available for boilers under 1000 #/hour) • Modular configuration to meet customer requirements includes: separator, legs (or wall bracket), aftercooler, temperature regulating valve and thermometer • Can be custom configured to meet customer requirements. • Stainless steel striking plate standard and • Multiple separators with manifold for high internal steel restrictor plates standard. pressure applications available. 64 Chart A — Boiler Blowdown Separators Blowdown Valve Size Separator H Dimensions Boiler Operating Pressure 0 - 15 14 16 - 50 20 51 - 100 20 101 - 125 34 126 - 150 34 151 - 175 34 176 - 200 34 201 - 225 34 **226 - 300 56 I * 1” D 1 1 1 1 1 1 1 1 1 2 2 3 3 3 3 3 4 4 1¼” 1½” 2” 2½” 3” V H I D V H I D V H I D V H I D V H I D V 2½ 2½ 2½ 3 3 4 4 4 4 20 20 34 34 34 34 34 56 56 1¼ 1¼ 1¼ 1¼ 1¼ 1¼ 1¼ 1¼ 1¼ 3 3 4 4 4 4 4 4 4 4 4 4 4 4 4 5 5 5 20 34 34 34 34 34 56 56 56 1½ 1½ 1½ 1½ 1½ 1½ 1½ 1½ 1½ 3 3 4 4 4 4 5 5 5 4 4 4 4 5 5 5 5 6 20 34 34 34 56 56 56 56 56 2 2 2 2 2 2 2 2 2 4 4 5 5 5 5 6 6 6 5 5 5 5 6 6 6 6 6 34 34 34 56 56 56 56 56 56 2½ 2½ 2½ 2½ 2½ 2½ 2½ 2½ 2½ 5 5 6 6 6 6 6 8 8 6 6 6 6 6 8 8 8 8 34 34 34 — — — — — — 3 3 3 — — — — — — 6 6 8 — — — — — — 5 5 6 — — — — — — *Minature Boilers: ½” - 1” Blowdown Valve up to 1000 #/hr. Blowdown use 14” high, 1” Inlet, 2” Drain, 2½” Vent. ** 251 - 300 PSIG required. U Symbol Construction and Stamping. See price sheet for adder. Chart B — Cooling Water Line and Valve Size Separator Inlet Size Cooling Water Pressure (PSI) Boiler Operating Pressure 0 - 50 51 - 100 101 - 125 Use for 50 - 70°F 126 - 175 Cooling Water Temperature 176 - 225 226 - 250 251 - 300 0 - 50 51 - 100 101 - 125 Use for 71 - 80°F 126 - 175 Cooling Water Temperature 176 - 225 226 - 250 251 - 300 40# 1” 60# 80# 40# 1¼” 60# 80# 40# 1½” 60# 80# 40# 2” 60# 80# 40# 2½” 60# 80# 40# 3” 60# 80# ½ 1 1 1 1 1¼ 1¼ ¾ 1 1 1 1 1¼ 1¼ ½ ¾ ¾ 1 1 1¼ 1¼ ½ ¾ 1 1 1 1¼ 1¼ ½ ¾ ¾ 1 1 1 1 ½ ¾ ¾ 1 1 1 1¼ 1 1 1¼ 1¼ 1¼ 1¼ 1¼ 1 1¼ 1¼ 1¼ 1¼ 1¼ 1½ 1 1 1 1¼ 1¼ 1¼ 1¼ 1 1 1¼ 1¼ 1¼ 1¼ 1¼ ¾ 1 1 1 1¼ 1¼ 1¼ 1 1 1 1¼ 1¼ 1¼ 1 1¼ 1¼ 1¼ 1¼ 1½ 1½ 1½ 1 1¼ 1¼ 1¼ 1¼ 1¼ 1½ 1 1¼ 1¼ 1¼ 1¼ 1¼ 1¼ 1 1¼ 1¼ 1¼ 1¼ 1¼ 1½ 1 1 1¼ 1¼ 1¼ 1¼ 1¼ 1 1¼ 1¼ 1¼ 1¼ 1¼ 1½ 1¼ 1½ 2 2 2 2 2 1¼ 2 2 2 2 2½ 2½ 1¼ 1¼ 1½ 2 2 2 2 1¼ 1½ 2 2 2 2 2 1¼ 1¼ 1¼ 1½ 2 2 2 1¼ 1¼ 1½ 2 2 2 2 1½ 2 2 2½ 2½ 2½ 2½ 2 2 2½ 2½ 2½ 2½ 2½ 1½ 2 2 2 2 2 2½ 1½ 2 2 2 2½ 2½ 2½ 1¼ 2 2 2 2 2 2 1½ 2 2 2 2 2 2½ 2 2½ 2½ 2½ 3 3 3 2½ 2½ 2½ 3 4 4 4 2 2½ 2½ 2½ 2½ 2½ 3 2 2½ 2½ 2½ 3 3 3 2 2 2½ 2½ 2½ 2½ 2½ 2 2 2½ 2½ 2½ 2½ 2½ © 2006 Burnham Commercial - Lancaster, PA Phone: 1-888-791-3790 www.burnhamcommercial.com 65 Conductivity Controller Surface Blowdown Solid State Intermittent Sampling • Controls boiler total dissolved solids (TDS) using conductivity measurement and automatic surface blowdown via intermittent sampling. • Adjustable interval timer (1/4 - 3 hours) periodically opens an electric valve to sample boiler water conductivity. • If the sample is below the micromhos set point • Adjustable sample duration timer (12 - 10 • Complete system includes: enclosure, on the potentiometer, blowdown is not required and the valve will close. If the sample is above the micromhos set point on the potentiometer, blowdown is required, and the valve will remain open. minutes) again samples to determine if sample is below the micromhos set point on the potentiometer to permit the valve to close. potentiometer, two timers and LED lights. • 120 VAC, 50/60 HZ, 15 amp • Solid state electronics • Valve assemblies purchased separately include: solenoid or motor-operated factory-piped valve with probe, tee assembly and orifice kit. • NEMA 4X enclosure 66 Conductivity Controller (Surface blowdown solid state intermittent sampling) Conductivity Range 0 - 7,000 Microsiemens/cm. Sample Timers Interval: 15 Minutes to 3 Hours / Duration: 30 Seconds to 10 Minutes Display LED Indicators: Power, Blowdown and Conductivity Calibration Accuracy +/-400 Microsiemens Drift Less than 0.25% Per Month Input Power 115 VAC, 50/60 HZ, 10 Amps Output/Control 115 VAC, 50/60 HZ, 10 Amps. Maximum Combined Load / Pre-wired for 2 or 4 Wire Blowdown Valve Environment Ambient Temperature: 40°F to 140°F (4°C to 60°C) Humidity: 1-100% R.H. Non-condensing Enclosure Nema 4X Weatherproof. See through Door with Padlockable Hasp. (3) 7/8” Diameter Holes Provided for 1/2” Conduit Connections: Blowdown Valve, AC Power, Probe and Optional Electrical Device. Dimensions H. 10” x W. 8” x D. 4” (25 x 20 x 10 cm) Net Weight 5.89 Lbs. (2.67 Kgs.) / 7.43 Lbs (3.48 Kgs.) - With Flow through Plumbing Assembly Note: Specifications subject to change without prior notice. © 2006 Burnham Commercial - Lancaster, PA Phone: 1-888-791-3790 www.burnhamcommercial.com 67 Water Softener Systems BS & BP Steel Tanks Electronic Demand Controller Features • Exchanges "soft" sodium ions for "hard" calcium and magnesium ions. • BS - Model range: 30-3/4 through BS-1200-3, twin or single (30,000 grain at 8 GPM through 1,200,000 grain at 280 GPM). • BP - Model range: 30-3/4 through BP-600-3, twin or single (30,000 grain at 8 GPM through 600,000 grain at 240 GPM). • Available in alternating "twin" configuration with flow meter and VIP computer demand controller or "single" configuration with time clock regeneration. Alternating twin system may be run in parallel twin mode. • Modular configuration to meet customer requirements for alternating system includes: resin tanks, resin, gravel, brine tank, control valve, blocking valves, flow meter and VIP computer demand controller. • VIP computer demand controller standard. • BS - Resin tanks: Steel "polybond" lined and primed, pressure- tested to 100 psig, non-code stamped (code stamped resin tanks available). • BP - Resin tanks: fiberglass reinforced polyester, pressure-tested, non-code stamped (code stamped resin tanks NOT available). • Provided with industry standard 30,000 grain per cubic foot resin. • Fleck control valve standard. • BS - Skid mounting (pre-piped/pre-wired) available as option. • BP - Skid mounting NOT available. 68 Twin Drawing Number Single Drawing Number 900225-1 900225-3 Cap. Max Grains (1,000) Cu. Ft. Continuous per GPM PSI Max. Min. Tank Flow Drop Peak PSI Drop Drain Flow Max 12 7 24 20 15 29 9 36 32 12 5 40 120 6 210 140 BS-240-1.5 240 272B BS-270-1.5 900253-8 302B 900227-1 900254-1 900227-2 Tank Dimensions Regeneration Resin Brine Salt Cap. Lbs. 2 10 x 52 18 x 38 400 15 6 3 12 x 52 18 x 38 400 30 12 25 5 14 x 66 18 x 38 400 45 18 16 5 14 x 66 18 x 38 400 45 18 48 22 7 18 x 66 21 x 43 450 60 24 13 58 25 7 18 x 66 21 x 43 450 75 30 42 15 59 25 10 18 x 66 27 x 51 1000 90 36 7 45 15 60 25 10 24 x 66 27 x 51 1000 105 42 160 8 45 15 60 25 10 24 x 66 27 x 51 1000 120 48 270 180 9 45 15 60 25 10 24 x 66 27 x 51 1000 135 54 BS-300-1.5 300 200 10 45 15 60 25 15 24 x 66 27 x 51 1000 150 60 122C BS-120-2 120 80 4 32 7 48 12 15 18 x 66 27 x 51 450 60 24 900254-2 152C BS-150-2 150 100 5 40 6 60 11 15 18 x 66 27 x 51 450 75 30 900227-3 900254-3 182C BS-180-2 180 120 6 48 9 72 15 15 18 x 66 27 x 51 1000 90 36 900227-4 900254-4 212C BS-210-2 210 140 7 58 8 84 15 15 24 x 66 27 x 51 1000 105 42 900227-5 900254-5 242C BS-240-2 240 160 8 64 11 96 20 15 24 x 66 27 x 51 1000 120 48 900227-6 900254-6 272C BS-270-2 270 180 9 72 13 108 25 15 24 x 66 27 x 51 1000 135 54 900227-7 900254-7 302C BS-300-2 300 200 10 78 15 108 25 15 24 x 66 27 x 51 1000 150 60 900227-8 900254-8 452C BS-450-2 450 300 15 87 15 118 25 20 30 x 66 32 x 51 1500 225 90 900227-9 900254-9 602C BS-600-2 600 400 20 94 15 125 25 25 36 x 71 42 x 51 2500 300 120 900228-1 900255-1 602E BS-600-3 600 400 20 160 15 240 25 30 36 x 71 42 x 51 2500 300 120 900228-2 900255-2 902E BS-900-3 900 600 30 200 15 270 25 40 42 x 71 42 x 51 2500 450 180 900228-3 900225-3 1202E BS-1200-3 1200 800 40 210 15 280 25 50 48 x 71 52 x 60 4500 600 240 Model Type Model Number 900252-1 32Z BS-30-.75 30 20 1 8 4 900252-3 62A BS-60-1 60 40 2 17 15 900225-4 900252-4 92A BS-90-1 90 60 3 21 900226-1 900253-1 92B BS-90-1.5 90 60 3 24 900226-2 900253-2 122B BS-120-1.5 120 80 4 900226-3 900253-3 152B BS-150-1.5 150 100 900226-4 900253-4 182B BS-180-1.5 180 900226-5 900253-5 212B BS-210-1.5 900226-6 900253-6 242B 900226-7 900253-7 900226-8 GPM Flow Max. Lbs. Min. Lbs. NOTE: Some flow rates are shown at a rate less than the standard 15 PSI drop for continuous and 25 PSI drop for decreased softening capacity as these flows are exceeded. Cap. Max Grains (1,000) Continuous Cu. Ft. per GPM PSI Tank Flow Drop Twin Drawing Number Single Drawing Number Model Type Model Number Max. Min. 900245-1 900232-1 31Z BP-30-.75 30 20 1 8 900245-3 900232-3 61A BP-60-1 60 40 2 900245-4 900232-4 91A BP-90-1 90 60 3 900246-1 900233-1 91B BP-90-1.5 90 60 3 900246-2 900233-2 121B BP-120-1.5 120 80 4 900246-3 900233-3 151B BP-150-1.5 150 100 900246-4 900233-4 181B BP-180-1.5 180 900246-5 900233-5 211B BP-210-1.5 210 900246-6 900233-6 241B BP-240-1.5 900246-7 900233-7 271B BP-270-1.5 900246-8 900233-8 301B 900247-1 900234-1 900247-2 900234-2 900247-3 900247-4 Peak GPM Flow PSI Drop Drain Flow Max 4 12 7 16 10 24 21 15 29 24 9 32 11 5 36 120 6 140 7 240 160 270 180 BP-300-1.5 300 121C BP-120-2 151C BP-150-2 900234-3 181C 900234-4 211C 900247-5 900234-5 900247-6 900247-7 Tank Dimensions Resin Brine Salt Cap. Lbs. 2 9 x 48 18 x 38 20 3 12 x 52 25 5 14 x 65 36 16 5 48 20 7 15 52 25 38 15 56 45 15 60 8 45 15 9 45 15 200 10 45 120 80 4 150 100 5 BP-180-2 180 120 BP-210-2 210 140 241C BP-240-2 240 160 900234-6 271C BP-270-2 270 900234-7 301C BP-300-2 300 900247-8 900234-8 451C BP-450-2 900247-9 900234-9 601C BP-600-2 900248-1 900235-1 601E BP-600-3 Regeneration Max. Lbs. Min. Lbs. 400 15 6 18 x 38 400 30 12 18 x 38 400 45 18 14 x 65 18 x 38 400 45 18 17 x 58 21 x 43 450 60 24 7 17 x 72 21 x 43 450 75 30 25 7 17 x 72 27 x 51 1000 90 36 25 15 24 x 71 27 x 51 1000 105 42 60 25 15 24 x 71 27 x 51 1000 120 48 60 25 15 24 x 71 27 x 51 1000 135 54 15 60 25 15 24 x 71 27 x 51 1000 150 60 32 6 48 10 7 17 x 58 21 x 43 450 60 24 40 10 60 16 7 17 x 72 21 x 43 450 75 30 6 48 9 72 23 7 17 x 72 27 x 51 1000 90 36 7 56 8 84 15 15 24 x 71 27 x 51 1000 105 42 8 64 11 96 20 15 24 x 71 27 x 51 1000 120 48 180 9 72 13 108 25 15 24 x 71 27 x 51 1000 135 54 200 10 78 15 108 25 15 24 x 71 27 x 51 1000 150 60 450 300 15 87 15 118 25 20 30 x 72 32 x 51 1500 225 90 600 400 20 94 15 125 25 25 36 x 72 42 x 51 2500 300 120 600 400 20 160 14 240 24 25 36 x 72 42 x 51 2500 300 120 NOTE: Some flow rates are shown at a rate less than the standard 15 PSI drop for continuous and 25 PSI drop for decreased softening capacity as these flows are exceeded. © 2006 Burnham Commercial - Lancaster, PA Phone: 1-888-791-3790 www.burnhamcommercial.com 69 Horizontal and Integral Deaerators The spray type deaerator is rated for oxygen removal to .005cc/I (7PPB) and CO 2 to zero measurable across its entire operating range. With its all stainless steel spring-loaded spray valve and second stage steam scrubber, the spray type deaerator is a good choice for all deaerator applications. Units are available with a complete range of boiler feedpumps and control options making them a total deaerator package with minimal amount of field assembly. Performance Features • Oxygen removal to .005 cc/I (7PPB) • CO2 removal to 0% measurable • Reduce chemical costs • Reduce boiler and system corrosion • Improve boiler efficiency • Pre-heat boiler feedwater • Quick equipment payback compared to chemical oxygen removal Construction Features • Constructed to ASME Section VIII, Division 1 for 50 PSIG • Easily accessible manway • Standard ten minute deaerator storage • Internal vent condenser for minimum steam loss • Self-adjusting spring-loaded stainless steel spray valve • Structural steel stand/pump platform • Two-stage deaeration • Available as completely packaged unit including pumps and control panel Horizontal Tank Design Integral Tank Design 70 Horizontal and Integral Deaerators Horizontal Tank Design Integral Tank Design 1 High water level control 9 Pump suction 2 Low water level control 10 Pump bypass 3 Make-up water control 11 Chemical port 4 Vacuum breaker 12 Drain 5 Temperature gauge 13 Sample port 6 Pressure gauge 14 High temperature condensate return 7 Overflow trap 15 Gauge glass 8 Vent 16 Manway access opening © 2006 Burnham Commercial - Lancaster, PA Phone: 1-888-791-3790 www.burnhamcommercial.com 71 Engineering & Application Data 72 ENG-3 73 ENG-4 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 TERMS AND CONDITIONS OF SALE FOR BURNHAM COMMERCIAL STEEL BOILERS PRICES AND TERMS OF PAYMENT A. Prices quoted are firm for no more then 30 days from the date of quotation subject to any conditions stated in Seller’s quotation or in an order submitted by Buyer and expressly accepted in writing by Seller. Seller will not be bound by any price sheet or quote other then a price quote signed by an authorized representative of Seller. B. Prices on orders accepted by Seller are firm, to the extent stated in the accepted order, subject to the following: 1. The purchase order must provide for shipment within six months of the date of purchase order. 2. Any shipment made more then six months after such a date is subject to a price adjustment, at Seller’s sole discretion, to the Seller’s price in effect at the time of shipment, which will not exceed 125% of the price on the acknowledged purchase order. 3. Any shipment more then 12 months after the date of purchase order will be invoiced at Seller’s price in effect at the time of shipment. C. On orders having a total price of less then $100,000 payment will be due “net in 30 days” from date of shipment, unless otherwise specifically agreed by Seller. On orders having a total purchase prices of $100,000 or more terms are 10% with order, 45% upon Seller’s receipt of Buyer’s approval of drawings, 45% within 30 days after shipment and 5% at the start-up of the products or within 90 days of shipment, which ever occurs sooner. D. The price of parts, components and other items not manufactured by Seller is subject to adjustments by Seller to reflect price changes by Seller’s suppliers. E. Orders accepted by Seller are subject to credit investigation and approval. If Buyer’s financial condition at any time does not justify the terms specified, Seller may require payment in advance of shipment or, if shipment has been made, recover shipment from the carrier. A service charge of 1-1/2% per month will be added to all accounts 30 days past due. F. Any tax or governmental change now or hereafter levied upon the production, sale, use or shipment of products ordered or sold will be charged to and paid by the Buyer, unless the Buyer has provided Seller with a tax exemption certification acceptable to the applicable taxing authorities. Such taxes are not covered in the selling price unless expressly stated on the quotation form. damages, consequential damages or penalties, whether on account of lost profits, or otherwise, unless specifically agree in writing signed by an authorized representative of Seller. SECURITY INTERESTS Not withstanding transfer of title to Buyer, the Seller retains and the Buyer hereby grants to the Seller a purchase money security interest in all products sold, and Buyer hereby irrevocably appoints Seller as its attorney-in-fact to execute and deliver, in Buyer’s name, any such financing statement of other documents as may be necessary under the Uniform Commercial Code or other applicable laws governing the items sold herein to perfect Seller’s interest therein. COMPLETE AGREEMENT The complete agreement between Seller and Buyer is contained herein and any specifications signed by the Seller, and no additional or different terms or conditions stated by Buyer shall be binding unless agreed to by Seller in writing. Neither course of dealings, not usage of trade shall be relevant to supplement or explain any terms used in this Agreement, and this Agreement may be modified only by a writing signed by both Seller and Buyer. The failure of Seller to insist upon strict performance of any of the terms and conditions stated herein shall not be considered as a continuing waiver of any such terms and conditions or any of Seller’s other rights. Buyer will obtain and maintain insurance against the loss or damage naming Seller as an additional insured in an amount sufficient to protect Seller’s interest in all products until the purchase price has been paid in full. CHANGES, ORDERS AND CANCELLATION Seller may adjust the selling price to cover any requested change in specification or other terms after the receipt of the Buyer’s order. Orders accepted by Burnham Commercial shall not be canceled by the Buyer except at Burnham Commercial’s sole discretion. In the event of any cancellation, Burnham Commercial reserves the right to impose a cancellation charge sufficient to cover all losses and out-of-pocket costs incurred by Seller in connection to such order, including materials and labor charges and cancellation charges from vendors, plus a cancellation charge of 20% of the original face amount of the order to compensate the Seller for its loss in profit. RETURNED GOODS Products may not be returned for refund or credit until after Seller has agreed to accept them. Inspection by a Seller representative may be required before return authorization is granted. A minimum restocking and handling charge of 25% (plus cost of any missing parts or components and inbound freight) will apply to all such returned products. All transportation charges for such products must be paid by Buyer. TRANSPORTATION TERMS AND CLAIMS Unless otherwise stated on Seller’s quotation form, all process are F.O.B Seller’s shipping point. Delivery to the initial carrier shall constitute delivery to the Buyer. Seller’s responsibility ceases and title the goods passes, subject to Seller’s security interests upon delivery in good order to such carrier, and all products are shipped at the Buyer’s risk. The Buyer agrees to examine all deliveries carefully before signing transportation receipts. If products are visibly damaged the Buyer shall require that written confirmation of damage be noted on the carrier’s delivery receipt and confirmed by the driver for the carrier. If damage is discovered after unpacking, the carrier shall be notified at once so that an inspection can be made and the claimed damage substantiated by the carrier. FORCE MAJEURE AND STORAGE A. Seller shall not be liable for any delay or failure in the delivery or shipment of products or for any damages suffered by reason of such delay or failure directly or indirectly, due to fire, flood, other weather conditions, accident, riots, war, embargo, labor stoppages, inadequate transportation facilities, shortage of materials or supplies, regulation by government authority or any cause beyond the Seller’s control. B. Seller reserves the right to allocate available production among its customers in any fair and reasonable manner that it determines is necessary or desirable. C. If delivery is delayed due to any cause beyond the Seller’s control, Buyer shall reimburse Seller for any added costs. Without limiting the foregoing, product on which manufacturer or delivery is delayed due to cause may be placed in storage by Seller, for the Buyers account and risk, and regular charges therefore and expense in connection therewith shall be paid by the Buyer. If, in Seller’s opinion, it is unable to obtain or continue such storage, the Buyer will, on request, provide or arrange for suitable storage facilities and assume all costs and risks in connection therewith. SHORTAGES, VARIANCES AND WEIGHTS No claims for variance from or shortages in orders will be considered unless present within 30 days after receipt of products. Any shipping weights are given or estimated are approximate, for the Buyer’s convenience only, and not guaranteed by Seller. LIMITS OF LIABILITY Any action by Buyer on this contract, must be commenced within one year after the cause of action accrues. Actions on Seller’s Warranties shall be limited as provided therein. Seller shall in no event have any liability for any liquidated PRODUCT CHANGES Seller reserves the right to make changes in products of any kind without prior notice, and to deliver revised designs or models of products against any order. Seller shall have no responsibility whatsoever with respect to changes made by the manufacturer of products sold but not manufactured by it. PATENTS Products manufactured and sold by Seller may be used by the Buyer pursuant to such patent rights as Seller may own or enjoy. Seller shall not liable for any use such products may be put as part of any system, mechanism or process covered by patent rights of others. TESTS Any tests requested by the Buyer to determine the performance of products covered by Seller’s quotation, must utilize procedures acceptable to Seller and the Buyer is responsible for costs thereof. Whenever an order includes start-up or service agreement, Seller shall not be obliged to provide start-up or other service as long as payment to Seller is default. CONFLICTING PROVISIONS OFFERED BY BUYER Any terms and conditions of Buyer’s purchase order which are different, from, in addition to inconsistent with the terms and conditions contained herein, are hereby objected to, and will not be binding on Seller in any manner whatsoever unless accepted by Seller in writing. Seller shall ship products referred to in this document only on the condition that the terms and conditions of sale set forth hereon shall be binding on the Buyer. APPLICABLE LAW Any order or contracts received by Seller from Buyer shall be governed by, construed and enforced by the laws of the Commonwealth of Pennsylvania. CHANGES IN TERMS These terms and conditions of sale are subject to change by Seller from time to time without prior notice. LIMITED WARRANTY LIMITED WARRANTY Subject to the terms and conditions herein, Seller warrants to the original owner at the original installation site that products manufactured by Seller (“Products”) comply, at the time of manufacture, with recognized hydronics industry regulatory agency standards and requirements therein effect and will be free from defects in materials and workmanship for a period of 12 months after the date of start-up or 18 months after the date of shipment, whichever shall be less (the “Warranty Period”) REMEDY A. The sole remedy for breach of this warranty is expressly limited to the repair or replacement of any part found to be defective under conditions of normal use within the Warranty Period. Installation is not included. B. Warranty – The owner must notify the original installer of the Product and Seller (Attention: Burnham Commercial, PO Box 3939, Lancaster, PA 17604) in writing, within the Warranty Period, providing a detailed description of all claimed defects. Transportation to a factory or other designated facility for repairs or any products or alleged defective shall, in all events, be the responsibility and at the cost of the owner. EXCLUSIONS Seller shall have no liability for: A. Incidental, special or consequential damages, such as loss of the use of products, facilities or production, inconvenience, loss of time or labor expense involved in the repairing or replacing of the alleged defective product. B. The performance of any Product under conditions varying materially from those under such Products is usually tested under industry standards as of the shipment time. C. Any damage to the Product due to abrasion, erosion, corrosion, deterioration, abnormal temperatures or the influence of foreign matter or energy. D. The design or operation of owner’s plant or equipment or of any facility or system of which any Product may be made a part. E. The suitability of any Product for any particular application. F. Any failure resulting from misuse, modification, not authorized by Seller in writing, improper installation or lack of proper maintenance. G. Equipment furnished by the owner, either mounted or unmounted, or when contracted for by owner to be installed or handled. Seller’s liability under this warranty shall not in any case exceed the amount paid for the Product found defective. THIRD-PARTY WARRANTIES For goods or components not manufactured by Seller, the warranty obligations or Seller shall, in all respects, conform and be limited to the warranty actually extended to Seller by its vendors. SEVERABILITY To the extent that any provisions of this warranty would be void or prohibited under applicable law, such provisions shall be limited in effect to the minimum extent necessary to render the remaining provisions hereof enforceable. 93 NO OTHER WARRANTIES Seller makes no implied warranty of merchantability or fitness for a particular purpose, or other warranties with respect to any products or services except as expressly set forth in this limited warranty. Form No. PL8146561001 - 4/04