ilux Digital User instructions Contents ilux Digital Shower and Bath – controller key Page 04 ilux Digital Shower – manual operation Page 05 ilux Digital Shower – pre-set operation Page 06 ilux Digital Shower – remote control Page 08 ilux Digital Bath – manual operation Page 09 ilux Digital Bath – pre-set operation Page 10 ilux Digital Bath – remote control Page 12 ilux Digital Shower with diverter & Bath with diverter – controller key Page 13 ilux Digital Shower with diverter – manual operation Page 14 ilux Digital Shower with diverter – pre-set operation Page 15 ilux Digital Shower with diverter – remote control Page 17 ilux Digital Bath with diverter – manual operation Page 18 ilux Digital Bath with diverter – pre-set operation Page 19 ilux Digital Bath with diverter – remote control Page 21 Cleaning and maintenance Page 22 Remote control battery change Page 22 03 ilux Digital Shower & Bath – controller key Digital Shower control 1. Start/Stop button with Rotary temperature control 1 2. Shower pre-set buttons 3. Rotary flow control and Pause button 2 Digital Bath control 3 1. Start/Stop button with Rotary temperature control 2. Bath pre-set buttons 3. Child safety Lock/Unlock buttons 4. Rotary flow control 1 04 2 3 4 ilux Digital Shower control – manual operation Digital Shower control The shower can be operated either manually or once set, via the pre-set buttons. To operate the shower manually follow the procedure below. 1. Press the Start/Stop button. 2. Rotate the temperature control to the desired position. The small red or blue temperature LEDs will flash while adjusting, the white LEDs remain solid, with more or less illuminating, to indicate the selected temperature position set by the rotary temperature control dial. 3. Rotate the flow control to the desired position. The LEDs will remain constantly lit, with more or less lights illuminating depending on where the flow rate is positioned. On a lesser flow rate, less lights will illuminate, on a greater flow rate more lights will illuminate. The green LED will illuminate when set to ‘ECO’ flow rate. 4. If required, the shower may be paused during operation. Press the Pause button. The LEDs will blink whilst the controller is in Pause mode. Press the Pause button again to resume showering. The shower will remain in Pause mode for 1 minute. If showering is not resumed within 1 minute, the controller will turn itself off. 5. Press the Start/Stop button to finish showering. 05 ilux Digital Shower control – pre-set operation Shower pre-set control To store the pre-set button settings follow the procedure below: 1. Press the Start/Stop button. 2. Select the desired temperature setting. 3. Select the desired flow rate. 4. Press and hold the desired pre-set button for 3 seconds. The selected pre-set button will remain constantly lit to indicate the controller has accepted the desired pre-set temperature and flow rate settings. 5. Press the Start/Stop button to finish showering. 06 ilux Digital Shower control – pre-set operation 6. Repeat the above procedure to store the remaining pre-set buttons. 7. Once set, the shower pre-set buttons may be erased and re-recorded by following the procedure above as required. To operate the shower using the pre-set buttons 1. Press the desired pre-set button. The shower will begin to operate to your pre-defined temperature and flow rate. 2. Press the Start/Stop button to finish showering. 3. The temperature and flow rate settings can be overridden and the pause feature will be active when the shower is operating in pre-set mode. 4. The shower can be operated manually or via the memory pre-set buttons. Due to performance characteristics of combination boilers, inlet temperature change may cause the following symptoms to be experienced during shower operation: Temperature LEDs may flash; this is not necessarily changing the outlet temperature. The shower flow rate may vary. Seasonal inlet temperature change may not offer a significant increase in shower flow rate. The operation of the Pause button will cause the combination boiler flow switch to cut out. It may take a few moments to reach the desired temperature once showering is resumed. 07 ilux Digital Shower remote control ilux Digital Shower remote control ilux Digital shower remote control is fully mobile and can be removed from the fixing cradle to a more convenient location, operating up to 10m from the Digital shower control. The remote control is water resistant though full submersion in water should be avoided. 1. To operate the shower in manual mode, press the Start/Stop button on the remote. 2. Once set at the controller, start the shower using the pre-set buttons by pressing the desired pre-set. The shower will start in the pre-set flow and temperature. When the remote battery power is running low, the green Eco flow setting LED on the shower control will glow red. 08 ilux Digital Bath control – manual operation The bath can be operated either manually or once set, via the pre-set buttons. To operate the bath manually follow the procedure below. 1. Press the Start/Stop button. 2. Rotate the temperature control to the desired position. The small red or blue temperature LEDs will flash while adjusting, the white LEDs remain solid, with more or less illuminating, to indicate the selected temperature position set by the rotary temperature control dial. 3. Rotate the flow control to the desired position. The LEDs will remain constantly lit, with more or less lights illuminating depending on where the flow rate is positioned. On a lesser flow rate, less lights will illuminate, on a greater flow rate more lights will illuminate. The green LED will illuminate when set to ‘ECO’ flow rate. 4. Put the plug in. 5. Press the Start/Stop button to finish bath fill. 09 ilux Digital Bath control – pre-set operation The bath controller features a child Safety Lock to disable the bath controls if a child is in the bathroom. 6. Once bath fill has been completed, press and hold the two Lock/Unlock buttons simultaneously for 3 seconds to activate the child Safety Lock feature. The padlock icon button will remain illuminated to indicate the controller is in child Safety Lock mode. 7. Press and hold the two Lock/Unlock buttons simultaneously for 3 seconds to unlock the bath controller. We do not recommend leaving a child unattended within a bathroom at any time. Bath pre-set control To store the pre-set button settings follow the procedure below: 1. Press the Start/Stop button. 2. Select the desired temperature setting. 3. Select the desired flow rate. 4. Put the plug in. 10 ilux Digital Bath control – pre-set operation 5. Press and hold the desired pre-set button for 3 seconds. The selected pre-set button will continue to flash to indicate the controller is in pre-set recording mode. The temperature and flow control functions will be disabled whilst the bath controller is in pre-set mode. 6. When the bath water is at the desired depth, press the Start/Stop button to complete the recording of bath fill depth and temperature. Differing user body mass will affect the overall depth of the bath. Care should be taken to ensure the bath does not overflow. 7. Repeat the above procedure to store the remaining pre-set buttons. 8. Once set, the bath pre-set buttons may be erased and re-recorded by following the procedure above as required. To operate the bath using the pre-set buttons 9. Put the plug in and press the desired pre-set button. The bath will start at the pre-defined temperature and flow rate. Consideration should be given to the length of time the plumbing system requires to reach the desired bath temperature and factored into the bath pre-set. 10. The temperature and flow rate settings can be overridden when the bath is operating in pre-set mode. To prevent accidental overfilling, once a bath has been filled using the pre-set function, the controller pre-set buttons will be disabled for 1 minute. The controls will still operate manually if required. 11. The bath fill can be operated manually or via the memory pre-set buttons. Due to performance characteristics of combination boilers, inlet temperature change may cause the following symptoms to be experienced during bath operation: The temperature LEDs may flash; this is not necessarily changing the outlet temperature. 11 ilux Digital Bath remote control Seasonal inlet temperature change may not offer a significant increase in bath flow rate. Bath flow rate may vary, therefore affecting bath pre-set depth. Consideration should be given to Winter and Summer flow rates. ilux Digital Bath remote control ilux Digital bath remote control is fully mobile and can be removed from the fixing cradle to a more convenient location, operating up to 10m from the Digital bath control. The remote control is water resistant though full submersion in water should be avoided. 1. Ensure the plug is engaged. 2. To operate the bath in manual mode, press the Start/Stop button on the remote. 3. Once set at the controller, start the bath using the pre-set buttons by pressing the desired pre-set. To prevent accidental overfilling, once a bath has been filled using the pre-set function the controller pre-set buttons will be disabled for 1 minute. The controls will still operate manually if required. 4. Whilst bathing, press the Hot Top Up button to provide a top up of maximum temperature at minimum flow of blended water, this will run for 1 minute before shutting off automatically. 5. Alternatively, press the Start/Stop button to finish the Hot Top Up flow. When the remote battery power is running low, the green Eco flow setting LED on the bath control will glow red. 12 ilux Digital Shower with diverter & Bath with diverter – controller key Digital Shower control 1. Start/Stop and divert button with Rotary temperature control 2. Shower pre-set buttons 1 3. Rotary flow control and Pause button 2 Digital Bath control 3 1. Start/Stop and divert button with Rotary temperature control 2. Bath pre-set buttons 3. Child safety Lock/Unlock buttons 4. Rotary flow control 1 2 3 4 13 ilux Digital Shower with diverter – manual operation Digital Shower control The shower can be operated either manually or once set, via the pre-set buttons. To operate the shower manually follow the procedure below. 1. Press the Start/Stop button, the shower will start in default outlet with flow and temperature as per previous use. To divert to alternative outlet, while showering, push and hold for 1.5 seconds to operate alternative outlet. Push and hold again to revert back. 2. Rotate the temperature control to the desired position. The small red or blue temperature LEDs will flash while adjusting, the white LEDs remain solid, with more or less illuminating, to indicate the selected temperature position set by the rotary temperature control dial. 3. Rotate the flow control to the desired position. The LEDs will remain constantly lit, with more or less lights illuminating depending on where the flow rate is positioned. On a lesser flow rate, less lights will illuminate, on a greater flow rate more lights will illuminate. The green LED will illuminate when set to ‘ECO’ flow rate. 4. If required, the shower may be paused during operation. Press the Pause button. The LEDs will blink whilst the controller is in Pause mode. Press the Pause button again to resume showering. The shower will remain in Pause mode for 1 minute. If showering is not resumed within 1 minute, the controller will turn itself off. 5. Press the Start/Stop button to finish showering. 14 ilux Digital Shower with diverter– pre-set operation Shower pre-set control To store the pre-set button settings, follow the procedure below: 1. Press the Start/Stop button. 2. Press and hold to select the desired outlet. 3. Select the desired temperature setting. 4. Select the desired flow rate. 5. Press and hold the desired pre-set button for 3 seconds. The selected pre-set button will remain constantly lit to indicate the controller has accepted the desired pre-set outlet, temperature and flow rate settings. 6. Press the Start/Stop button to finish showering. 15 ilux Digital Shower with diverter – pre-set operation 7. Repeat the above procedure to store the remaining pre-set buttons. 8. Once set, the shower pre-set buttons may be erased and re-recorded by following the procedure above as required. To operate the shower using the pre-set buttons 1. Press the desired pre-set button. The shower will begin to operate to your pre-defined outlet, temperature and flow rate. 2. Press the Start/Stop button to finish showering. 3. The temperature and flow rate settings can be overridden and the pause feature will be active when the shower is operating in pre-set mode. 4. The shower can be operated manually or via the memory pre-set buttons. Due to performance characteristics of combination boilers, inlet temperature change may cause the following symptoms to be experienced during shower operation: Temperature LEDs may flash; this is not necessarily changing the outlet temperature. The shower flow rate may vary. Seasonal inlet temperature change may not offer a significant increase in shower flow rate. The operation of the Pause button will cause the combination boiler flow switch to cut out. It may take a few moments to reach the desired temperature once showering is resumed. 16 ilux Digital Shower with diverter remote control ilux Digital Shower remote control ilux Digital shower remote control is fully mobile and can be removed from the fixing cradle to a more convenient location, operating up to 10m from the Digital bath control. The remote control is water resistant though full submersion in water should be avoided. 1. To operate the shower in manual mode, press the Start/Stop button on the remote, the shower will start in the last used flow and temperature setting with water coming from the default outlet as set on commissioning. To switch to an alternative outlet, press and hold the Start/Stop button. 2. Once set at the controller, start the shower using the pre-set buttons by pressing the desired pre-set. The shower will start in the pre-set outlet, flow and temperature. When the remote battery power is running low, the green Eco flow setting LED on the shower control will glow red. 17 ilux Digital Bath with diverter – manual operation The bath can be operated either manually or once set, via the pre-set buttons. To operate the bath manually follow the procedure below. 1. Press the Start/Stop button, the bath will start in the default outlet with flow and temperature as per previous use. To divert to alternative outlet while bathing, push and hold for 1.5 seconds to operate alternative outlet. Push and hold again to revert back. 2. Rotate the temperature control to the desired position. The small red or blue temperature LEDs will flash while adjusting, the white LEDs remain solid, with more or less illuminating, to indicate the selected temperature position set by the rotary temperature control dial. 3. Rotate the flow control to the desired position. The LEDs will remain constantly lit, with more or less lights illuminating depending on where the flow rate is positioned. On a lesser flow rate, less lights will illuminate, on a greater flow rate more lights will illuminate. The green LED will illuminate when set to ‘ECO’ flow rate. 4. Put the plug in. 5. Press the Start/Stop button to finish bath fill. 18 ilux Digital Bath with diverter – pre-set operation The bath controller features a child Safety Lock to disable the bath controls if a child is in the bathroom. 6. Once bath fill has been completed, press and hold the two Lock/Unlock buttons simultaneously for 3 seconds to activate the child Safety Lock feature. The padlock icon button will remain illuminated to indicate the controller is in child Safety Lock mode. 7. Press and hold the two Lock/Unlock buttons simultaneously for 3 seconds to unlock the bath controller. We do not recommend leaving a child unattended within a bathroom at any time. Bath pre-set control To store the pre-set button settings follow the procedure below: 1. Press the Start/Stop button. 2. Press and hold to select the desired outlet. 3. Select the desired temperature setting. 4. Select the desired flow rate. 5. Put the plug in. 19 ilux Digital Bath with diverter – pre-set operation 6. Press and hold the desired pre-set button for 3 seconds. The selected pre-set button will continue to flash to indicate the controller is in pre-set recording mode. The temperature and flow control functions will be disabled whilst the bath controller is in pre-set mode. 7. When the bath water is at the desired depth, press the Start/Stop button to complete the recording of bath fill depth and temperature. Differing user body mass will affect the overall depth of the bath. Care should be taken to ensure the bath does not overflow. 8. Repeat the above procedure to store the remaining pre-set buttons. 9. Once set, the bath pre-set buttons may be erased and re-recorded by following the procedure above as required. To operate the bath using the pre-set buttons 10. Put the plug in and press the desired pre-set button. The bath will start at the pre-defined outlet, temperature and flow rate. Consideration should be given to the length of time the plumbing system requires to reach the desired bath temperature and factored into the bath pre-set. 11. The temperature and flow rate settings can be overridden when the bath is operating in pre-set mode. To prevent accidental overfilling, once a bath has been filled using the pre-set function, the controller pre-set buttons will be disabled for 1 minute. The controls will still operate manually if required. 12. The bath fill can be operated manually or via the memory pre-set buttons. Due to performance characteristics of combination boilers, inlet temperature change may cause the following symptoms to be experienced during bath operation: The temperature LEDs may flash; this is not necessarily changing the outlet temperature. 20 ilux Digital Bath with diverter remote control Seasonal inlet temperature change may not offer a significant increase in bath flow rate. Bath flow rate may vary, therefore affecting bath pre-set depth. Consideration should be given to Winter and Summer flow rates. ilux Digital Bath remote control ilux Digital Bath remote control is fully mobile and can be removed from the fixing cradle to a more convenient location, operating up to 10m from the Digital bath control. The remote control is water resistant though full submersion in water should be avoided. 1. Ensure the plug is engaged. 2. To operate the bath in manual mode, press the Start/Stop button on the remote. 3. Once set at the controller, start the bath using the pre-set buttons by pressing the desired pre-set. To prevent accidental overfilling, once a bath has been filled using the pre-set function the controller pre-set buttons will be disabled for 1 minute. The controls will still operate manually if required. 4. Whilst bathing, press the Hot Top Up button to provide a top up of maximum temperature at minimum flow of blended water, this will run for 1 minute before shutting off automatically. 5. Alternatively, press the Start/Stop button to finish the Hot Top Up flow. When the remote battery power is running low, the green Eco flow setting LED on the bath control will glow red. 21 Cleaning and maintenance Cleaning Your ilux Digital product should be cleaned using only a soft cloth and washing up liquid. DO NOT USE ABRASIVE CLEANERS. To reduce the need for chemical descaling in hard water areas, ilux Digital shower heads incorporate a ‘clear flow’ system whereby any scale build up can be broken down by gently rubbing the flexible tips of the jets during use. This should be carried out as often as once a week in hard water areas, as scale build-up can affect the spray pattern and cause the shower to perform poorly. Failure to descale the shower head can affect the internal seals and may affect the warranty. Should chemical descaling of the shower head ever become necessary, simply remove the shower head from the shower hose and soak it in a mild proprietary descalent. Remote control battery change instructions: 1. Using a small posidrive screwdriver, carefully undo the 3 fixing screws and remove the battery cover. 2. Remove the battery and wait for 2 minutes to decharge the capacitors. Replace the battery with a CR2032 battery, available from Aqualisa customer service on 01959 560010 part number, 489501. 3. Ensuring the battery seal is in the correct position to create a water tight seal, replace the battery cover and secure using the fixing screws. Incorrect fitting of the battery seal will mean the remote control is no longer waterproof. Any product problems arising from incorrect battery replacement, or if any other replacement battery is used, will not be covered by our terms of guarantee. 22 Notes 23 Aqualisa Products Limited The Flyer’s Way Westerham Kent TN16 1DE Customer helpline: 01959 560010 Brochure Hotline: 0800 652 3669 Website: www.aqualisa.co.uk Email: enquiries@aqualisa.co.uk Republic of Ireland Sales enquiries: 01-864-3363 Service enquiries: 01-844-3212 Part No:700540 Issue 01 Nov 12 Please note that calls may be recorded for training and quality purposes The company reserves the right to alter, change or modify the product specifications without prior warning ® Registered Trademark Aqualisa Products Limited