Surion Distributed by Electro-Stock, Inc. sales@electrostock.com 630-682-1542 Fax 630-682-1562 http://www.electrostock.com Thermal and magnetic protection Motor protection devices GPS1B Standards/Approvals Characteristics B IEC 60947-1, 60947-2, 60947-4-1 DIN VDE 0660T 100/101/102 UL508/CSA - UL508/cULus Shipping approvals: C RINA • Rocker and rotary handle operator • Thermal and magnetic protection • Standard and high breaking capacity Icu = 100kA G Ics = 100% Icu Icu < 100kA G Ics min. 75% Icu • Clear identification of the operation state (ON-OFF-tripped) • Ambient temperature compensation • Phase failure protection A Bureau Veritas Lloyd’s Register Germanischer Lloyd D cULus E CE Auxiliaries F G H Technical performances I X Accessories Auxiliaries ! pg. B.16 Busbar system ! pg. B.19 Technical data Dimensions Fuseless starters Coordination tables ! ! ! ! pg. B.22 pg. B.28 pg. D.2 pg. D.5 Rated current In Rated operational current Ie (A) Rated power at 400Vac Utilisation category IEC 60947-2 (circuit breaker) IEC 60947-4-1 (MMS) Tripping class IEC 60947-4-1 Magnetic release Ie max. Mechanical/electrical endurance (A) (kW) (A) 0.1-32 0.1-32 0.02-15 A AC-3 10 x13 100,000 Surion GPS1B - Standard breaking capacity CLASS 10 Rated power Rated current Thermal Instantaneous Rated service Rated current short-circuit short-circuit ultimate setting range release breaking short-circuit capacity at breaking 400V capacity at 400V (A) (A) Ics (kA) Icu (kA) In (1) (kW) (A) 0.02 0.06 0.09 0.12/0.18 0.25 0.37/0.55 0.75 1.5 2.2 3/4 5.5 7.5 10 11 15 0.16 0.25 0.4 0.63 1 1.6 2.5 4 6.3 10 13 16 20 25 32 0.1 - 0.16 0.16 - 0.25 0.25 - 0.4 0.4 - 0.63 0.63 - 1 1 - 1.6 1.6 - 2.5 2.5 - 4 4 - 6.3 6.3 - 10 9 - 13 11 - 16 14 - 20 19 - 25 24 - 32 2.1 3.3 5.2 8.2 13 20.8 32.5 52 81.9 130 169 208 260 325 416 100 100 100 100 100 100 100 100 100 100 50 25 25 25 25 0.02 0.06 0.09 0.12/0.18 0.25 0.37/0.55 0.75 1.5 2.2 3/4 5.5 7.5 10 11 15 0.16 0.25 0.4 0.63 1 1.6 2.5 4 6.3 10 13 16 20 25 32 0.1 - 0.16 0.16 - 0.25 0.25 - 0.4 0.4 - 0.63 0.63 - 1 1 - 1.6 1.6 - 2.5 2.5 - 4 4 - 6.3 6.3 - 10 9 - 13 11 - 16 14 - 20 19 - 25 24 - 32 2.1 3.3 5.2 8.2 13 20.8 32.5 52 81.9 130 169 208 260 325 416 100 100 100 100 100 100 100 100 100 100 50 25 25 25 25 Cat. no. Ref. no. Pack. 100 100 100 100 100 100 100 100 100 100 38 19 19 19 19 GPS1BSAA GPS1BSAB GPS1BSAC GPS1BSAD GPS1BSAE GPS1BSAF GPS1BSAG GPS1BSAH GPS1BSAJ GPS1BSAK GPS1BSAL GPS1BSAM GPS1BSAN GPS1BSAP GPS1BSAR 101211 101212 101213 101214 101215 101216 101217 101218 101219 101220 101221 101222 101223 101224 101225 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 100 100 100 100 100 100 100 100 100 100 38 19 19 19 19 GPS1BSAAMP GPS1BSABMP GPS1BSACMP GPS1BSADMP GPS1BSAEMP GPS1BSAFMP GPS1BSAGMP GPS1BSAHMP GPS1BSAJMP GPS1BSAKMP GPS1BSALMP GPS1BSAMMP GPS1BSANMP GPS1BSAPMP GPS1BSARMP 101195 101196 101197 101198 101199 101200 101201 101202 101203 101204 101205 101206 101207 101208 101209 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 (1) Rated current: highest thermal current setting range value. 3 phase motors at 400Vac Pn Rated current In (1) (kW) (A) 0.02 0.06 0.09 0.12/0.18 0.25 0.37/0.55 0.75 1.5 2.2 3/4 5.5 7.5 10 11 15 0.16 0.25 0.4 0.63 1 1.6 2.5 4 6.3 10 13 16 20 25 32 2.1 3.3 5.2 8.2 13 20.8 32.5 52 81.9 130 169 208 260 325 416 B D Thermal Rated Instantaneous Rated service current ultimate short-circuit short-circuit setting range short-circuit release breaking breaking capacity at capacity at 400V 400V (A) (A) Icu (kA) Ics (kA) 0.1 - 0.16 0.16 - 0.25 0.25 - 0.4 0.4 - 0.63 0.63 - 1 1 - 1.6 1.6 - 2.5 2.5 - 4 4 - 6.3 6.3 - 10 9 - 13 11 - 16 14 - 20 19 - 25 24 - 32 A C GPS1B - High breaking capacity. CLASS 10 Rated power Manual motor starter 3 phase motors at 400Vac Pn 100 100 100 100 100 100 100 100 100 100 100 50 50 50 50 100 100 100 100 100 100 100 100 100 100 100 38 38 38 38 Cat. no. Ref. no. Pack. E GPS1BHAA GPS1BHAB GPS1BHAC GPS1BHAD GPS1BHAE GPS1BHAF GPS1BHAG GPS1BHAH GPS1BHAJ GPS1BHAK GPS1BHAL GPS1BHAM GPS1BHAN GPS1BHAP GPS1BHAR 101234 101235 101236 101237 101238 101239 101240 101241 101242 101243 101244 101245 101246 101247 101248 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 F G H I (1) Rated current: highest thermal current setting range value. X Distributed by Electro-Stock, Inc. sales@electrostock.com 630-682-1542 Fax 630-682-1562 http://www.electrostock.com Surion Distributed by Electro-Stock, Inc. sales@electrostock.com 630-682-1542 Fax 630-682-1562 http://www.electrostock.com Thermal and magnetic protection Motor protection devices GPS2B Standards/Approvals Characteristics B IEC 60947-1, 60947-2, 60947-4-1 DIN VDE 0660T 100/101/102 UL508/CSA - UL508/cULus Shipping approvals: C RINA • Rotary handle operator • Thermal and magnetic protection • Standard and high breaking capacity Icu = 100kA G Ics = 100% Icu Icu < 100kA G Ics min. 75% Icu • Clear identification of the operation state (ON-OFF-tripped) • Ambient temperature compensation • Phase failure protection A Bureau Veritas Lloyd’s Register Germanischer Lloyd D cULus E CE Technical performances Auxiliaries Rated current In Rated operational current Ie Rated power at 400Vac Utilisation category IEC 60947-2 (circuit breaker) IEC 60947-4-1 (MMS) Tripping class IEC 60947-4-1 Magnetic release Ie max. Mechanical/electrical endurance F G H I X Accessories Auxiliaries ! pg. B.16 Busbar system ! pg. B.19 Technical data Dimensions Fuseless starters Coordination tables ! ! ! ! pg. B.22 pg. B.28 pg. D.2 pg. D.5 (A) (A) (kW) (A) 10-63 10-63 4-30 A AC-3 10 x13 50,000/25,000 Surion GPS2B - Standard breaking capacity CLASS 10 Rated current In (1) (kW) (A) 3/4 5.5 7.5 10 11 15 18.5 22 30 10 13 16 20 25 32 40 50 63 Thermal Instantaneous Rated Rated service current short-circuit ultimate short-circuit setting range release short-circuit breaking breaking capacity at capacity at 400V 400V (A) (A) Icu (kA) Ics (kA) 6.3 - 10 9 - 13 11 -16 14 - 20 19 - 25 24 - 32 28 - 40 35 - 50 45 - 63 130 169 208 260 325 416 520 650 819 100 50 25 25 25 25 25 25 25 100 38 19 19 19 19 19 19 19 Cat. no. Ref. no. Pack. GPS2BSAK GPS2BSAL GPS2BSAM GPS2BSAN GPS2BSAP GPS2BSAR GPS2BSAS GPS2BSAT GPS2BSAU 101226 107119 101227 101228 101229 101230 101231 101232 101233 1 1 1 1 1 1 1 1 1 Cat. no. Ref. no. Pack. (1) Rated current: highest thermal current setting range value. GPS2B - High breaking capacity CLASS 10 Rated power 3 phase motors at 400Vac Pn Rated current In (1) Thermal Instantaneous Short-circuit Short-circuit breaking current breaking short-circuit capacity at setting range capacity at release 400V 400V (kW) (A) (A) (A) Icu (kA) Ics (kA) 3/4 5.5 7.5 10 11 15 18.5 22 30 10 13 16 20 25 32 40 50 63 6.3 - 10 9 - 13 11 -16 14 - 20 19 - 25 24 - 32 28 - 40 35 - 50 45 - 63 130 169 208 260 325 416 520 650 819 100 100 50 50 50 50 50 50 50 100 100 38 38 38 38 38 38 38 Manual motor starter Rated power 3 phase motors at 400Vac Pn A B GPS2BHAK GPS2BHAL GPS2BHAM GPS2BHAN GPS2BHAP GPS2BHAR GPS2BHAS GPS2BHAT GPS2BHAU 101249 107120 101250 101251 101252 101253 101254 101255 101256 1 1 1 1 1 1 1 1 1 C D E (1) Rated current: highest thermal current setting range value. F G H I X Distributed by Electro-Stock, Inc. sales@electrostock.com 630-682-1542 Fax 630-682-1562 http://www.electrostock.com Surion Distributed by Electro-Stock, Inc. sales@electrostock.com 630-682-1542 Fax 630-682-1562 http://www.electrostock.com Magnetic protection Motor protection devices GPS1M Standards/Approvals Characteristics B IEC 60947-1, 60947-2, 60947-4-1 DIN VDE 0660T 100/101/102 UL508/CSA - UL508/cULus Shipping approvals: C RINA • Short-circuit protection for starters • Rocker and rotary handle operator • Magnetic protection • Standard and high breaking capacity Icu = 100kA G Ics = 100% Icu Icu < 100kA G Ics min. 75% Icu • Clear identification of the operation state (ON-OFF-tripped) A Bureau Veritas Lloyd’s Register Germanischer Lloyd D cULus CE E F Auxiliaries G H I X Accessories Auxiliaries ! pg. B.16 Busbar system ! pg. B.19 Technical data Dimensions Fuseless starters Coordination tables ! ! ! ! pg. B.22 pg. B.28 pg. D.2 pg. D.5 Technical performances Rated current In Rated operational current Ie Utilisation category IEC 60947-2 (circuit breaker) Magnetic release Ie max. Mechanical/electrical endurance (A) (A) 0.1-32 0.1-32 (A) A x13 100.000 Surion GPS1M - Standard breaking capacity Rated current In (kW) (A) 0.02 0.06 0.09 0.12/0.18 0.25 0.37/0.55 0.75 1.5 2.2 3/4 5.5 7.5 10 11 15 0.16 0.25 0.4 0.63 1 1.6 2.5 4 6.3 10 13 16 20 25 32 Thermal Instantaneous Rated Rated service current short-circuit ultimate short-circuit setting range release short-circuit breaking (1) breaking capacity at capacity at 400V 400V (A) (A) Icu (kA) Ics (kA) - 2.1 3.3 5.2 8.2 13 20.8 32.5 52 81.9 130 169 208 260 325 416 100 100 100 100 100 100 100 100 100 100 50 25 25 25 25 100 100 100 100 100 100 100 100 100 100 38 19 19 19 19 Cat. no. Ref. no. Pack. GPS1MSAA GPS1MSAB GPS1MSAC GPS1MSAD GPS1MSAE GPS1MSAF GPS1MSAG GPS1MSAH GPS1MSAJ GPS1MSAK GPS1MSAL GPS1MSAM GPS1MSAN GPS1MSAP GPS1MSAR 101257 101258 101259 101260 101261 101262 101263 101264 101265 101266 101267 101268 101269 101270 101271 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Cat. no. Ref. no. Pack. (1) Select appropriate thermal overload relay for the starter. See chapter C pages C.62 - C.68. GPS1M - High breaking capacity Thermal Instantaneous Rated Rated service Rated power Rated current In current short-circuit ultimate short-circuit 3 phase setting range release short-circuit breaking motors at (1) breaking capacity at 400Vac Pn capacity at 400V 400V (A) (A) (A) Icu (kA) Ics (kA) (kW) 0.02 0.06 0.09 0.12/0.18 0.25 0.37/0.55 0.75 1.5 2.2 3/4 5.5 7.5 10 11 15 0.16 0.25 0.4 0.63 1 1.6 2.5 4 6.3 10 13 16 20 25 32 - 2.1 3.3 5.2 8.2 13 20.8 32.5 52 81.9 130 169 208 260 325 416 100 100 100 100 100 100 100 100 100 100 100 50 50 50 50 100 100 100 100 100 100 100 100 100 100 100 38 38 38 38 Manual motor starter Rated power 3 phase motors at 400Vac Pn A B GPS1MHAA GPS1MHAB GPS1MHAC GPS1MHAD GPS1MHAE GPS1MHAF GPS1MHAG GPS1MHAH GPS1MHAJ GPS1MHAK GPS1MHAL GPS1MHAM GPS1MHAN GPS1MHAP GPS1MHAR 101280 101281 101282 101283 101284 101285 101286 101287 101288 101289 101290 101291 101292 101293 101294 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 (1) Select appropriate thermal overload relay for the starter. See chapter C pages C.62 - C.68. C D E F G H I X Distributed by Electro-Stock, Inc. sales@electrostock.com 630-682-1542 Fax 630-682-1562 http://www.electrostock.com Surion Distributed by Electro-Stock, Inc. sales@electrostock.com 630-682-1542 Fax 630-682-1562 http://www.electrostock.com Magnetic protection Motor protection devices GPS2M Standards/Approvals Characteristics B IEC 60947-1, 60947-2, 60947-4-1 DIN VDE 0660T 100/101/102 UL508/CSA - UL508/cULus Shipping approvals: C RINA • Short-circuit protection for starters • Rotary handle operator • Magnetic protection • Standard and high breaking capacity Icu = 100kA G Ics = 100% Icu Icu < 100kA G Ics min. 75% Icu • Clear identification of the operation state (ON-OFF-tripped) A Bureau Veritas Lloyd’s Register Germanischer Lloyd D CE Technical performances E Auxiliaries Rated current In Rated operational current Ie Utilisation category IEC 60947-2 (circuit breaker) Magnetic release Ie max. Mechanical/electrical endurance F G H I X Accessories Auxiliaries ! pg. B.16 Busbar system ! pg. B.19 Technical data Dimensions Fuseless starters Coordination tables ! ! ! ! pg. B.22 pg. B.28 pg. D.2 pg. D.5 (A) (A) 10-63 10-63 (A) A x13 50,000/25,000 Surion GPS2M - Standard breaking capacity Rated current In (kW) (A) 4 5.5 7.5 10 11 15 18.5 22 30 10 13 16 20 25 32 40 50 63 Thermal Instantaneous Rated Rated service ultimate current short-circuit short-circuit short-circuit setting range breaking release (1) breaking capacity at capacity at 400V 400V (A) Icu (kA) Ics (kA) (A) - 130 169 208 260 325 416 520 650 819 100 50 25 25 25 25 25 25 25 100 38 19 19 19 19 19 19 19 Cat. no. Ref. no. Pack. GPS2MSAK GPS2MSAL GPS2MSAM GPS2MSAN GPS2MSAP GPS2MSAR GPS2MSAS GPS2MSAT GPS2MSAU 101272 107121 101273 101274 101275 101276 101277 101278 101279 1 1 1 1 1 1 1 1 1 Cat. no. Ref. no. Pack. (1) Select appropriate thermal overload relay for the starter. See chapter C pages C.64 - C.68. GPS2M - High breaking capacity Rated power 3 phase motors at 400Vac Pn Rated current In (kW) (A) 4 5.5 7.5 10 11 15 18.5 22 30 10 13 16 20 25 32 40 50 63 Instantaneous Thermal Rated Rated service short-circuit current ultimate short-circuit release setting range short-circuit breaking (1) breaking capacity at capacity at 400V 400V (A) (A) Icu (kA) Ics (kA) - 130 169 208 260 325 416 520 650 819 100 100 50 50 50 50 50 50 50 100 100 38 38 38 38 38 38 38 Manual motor starter Rated power 3 phase motors at 400Vac Pn A B GPS2MHAK GPS2MHAL GPS2MHAM GPS2MHAN GPS2MHAP GPS2MHAR GPS2MHAS GPS2MHAT GPS2MHAU 101295 107122 101296 101297 101298 101299 101300 101301 101302 1 1 1 1 1 1 1 1 1 C D E (1) Select appropriate thermal overload relay for the starter. See chapter C pages C.63 - C.68. F G H I X Distributed by Electro-Stock, Inc. sales@electrostock.com 630-682-1542 Fax 630-682-1562 http://www.electrostock.com Surion Distributed by Electro-Stock, Inc. sales@electrostock.com 630-682-1542 Fax 630-682-1562 http://www.electrostock.com Motor protection devices Auxiliaries Standards/Approvals Product range B IEC 60947-1, 60947-2, 60947-4-1 DIN VDE 0660T 100/101/102 UL508/CSA - UL508/cULus Shipping approvals: C RINA • Auxiliary contacts (frontal & lateral) • Alarm contact block • Auxiliary and alarm contact block • Short-circuit alarm contact block • Shunt trip • Undervoltage release • Undervoltage release with 2NO early make contacts • External handle operator • Terminal protector • Busbar system A Bureau Veritas Lloyd’s Register Germanischer Lloyd D cULus CE E Auxiliaries F G H I X Technical performances Accessories Auxiliaries ! pg. B.16 Busbar system ! pg. B.19 Technical data Dimensions Fuseless starters Coordination tables ! ! ! ! pg. B.22 pg. B.28 pg. D.2 pg. D.5 • All auxiliaries can be mounted and changed easily, without any tools • Both frames GPS1 and GPS2 uses same auxiliaries • All terminals are capable for 2 cables (0.5mm2 - 2.5mm2) • Side auxiliary contacts are rated to A600, P300 duty • Frontal auxiliary contacts are rated to B300, Q300 duty • Minimum operational contact 5mA, 17Vdc • All terminal screwhead are Pozidriv 2 and slotted combination Surion Auxiliary contact blocks Description For use with Type Cat. no. Ref. no. Pack. Maximum 2 auxiliary contact blocks per manual motor starter GPS1... and GPS2... GPS1... and GPS2... 1 NO 1 NC GPAC10FBA GPAC01FBA 101303 101304 10 10 Lateral Two contacts Side mounting on the left GPS1... and GPS2... GPS1... and GPS2... GPS1... and GPS2... 1 NO + 1 NC 2 NO 2 NC GPAC11LLA GPAC20LLA GPAC02LLA 101305 101306 101307 10 10 10 Two contacts Side mounting on the right GPS1... and GPS2... GPS1... and GPS2... GPS1... and GPS2... 1 NO + 1 NC 2 NO 2 NC GPAC11LRA GPAC20LRA GPAC02LRA 101308 101309 101310 10 10 10 A Alarm contact block Description Frontal mounting on the right Single contact Manual motor starter Frontal For use with Type Cat. no. Ref. no. Pack. GPS1... and GPS2... GPS1... and GPS2... 1 NO 1 NC GPAL10FRA GPAL01FRA 101311 101312 10 10 B C D Auxiliary / alarm contact block Description Side mounting on the left (front alarm contact block can not be used at the same time) Two contacts For use with Type Cat. no. Ref. no. Pack. E GPS1... and GPS2... GPS1... and GPS2... GPS1... and GPS2... GPS1... and GPS2... 1 NO(Alarm)+1 NO(Aux.) 1 NO(Alarm)+1 NC(Aux.) 1 NC(Alarm)+1 NO(Aux.) 1 NC(Alarm)+1 NC(Aux.) GPAD1010LLA GPAD1001LLA GPAD0110LLA GPAD0101LLA 101313 101314 101315 101316 10 10 10 10 F G H Short-circuit alarm contact block Description Side mounting on the left Two contacts NO + NC Mechanical indication marking For use with Type Cat. no. Ref. no. Pack. GPS1... and GPS2... 1 NO + 1 NC GPAE11LLA 101317 10 I X Distributed by Electro-Stock, Inc. sales@electrostock.com 630-682-1542 Fax 630-682-1562 http://www.electrostock.com Surion Shunt trip device Description Motor protection devices Side mounting on the right Can not be used together with the undervoltage trip device For use with Coil voltage Ref. no. Pack. 101318 101319 101320 101321 101322 101323 101324 101325 101326 101327 101328 101329 101194 5 5 5 5 5 5 5 5 5 5 5 5 5 Ref. no. Pack. 101330 101331 101332 101333 101334 101335 101336 101337 101338 101339 101340 102625 10 10 10 10 10 10 10 10 10 10 10 10 24V 50Hz GPAU20LTAAD 24V 60Hz GPAU20LTAAC 48V 50Hz GPAU20LTAAG 48V 60Hz GPAU20LTAAF 110/127V 50Hz / 120V 60Hz GPAU20LTAAJ 208V 60Hz GPAU20LTAAM 220/230V 50Hz / 240/260V 60Hz GPAU20LTAAN 240V 50Hz / 277V 60Hz GPAU20LTAAR 380/400V 50Hz GPAU20LTAAU 415/440V 50Hz / 460/480V 60Hz GPAU20LTAAW 500V 50Hz / 600V 60Hz GPAU20LTAAY 100V 50/60Hz GPAU20LTAA11 101341 101342 101343 101344 101345 101346 101347 101348 101349 101350 101351 110360 10 10 10 10 10 10 10 10 10 10 10 10 24V 50Hz GPS1*H and GPS2... GPAU20LCAAD 24V 60Hz GPS1*H and GPS2... GPAU20LCAAC 48V 50Hz GPS1*H and GPS2... GPAU20LCAAG 48V 60Hz GPS1*H and GPS2... GPAU20LCAAF GPS1*H and GPS2... 110/127V 50Hz / 120V 60Hz GPAU20LCAAJ 208V 60Hz GPS1*H and GPS2... GPAU20LCAAM GPS1*H and GPS2... 220/230V 50Hz / 240/260V 60Hz GPAU20LCAAN GPAU20LCAAR GPS1*H and GPS2... 240V 50Hz / 277V 60Hz 380/400V 50Hz GPAU20LCAAU GPS1*H and GPS2... GPS1*H and GPS2... 415/440V 50Hz / 460/480V 60Hz GPAU20LCAAW GPAU20LCAAY GPS1*H and GPS2... 500V 50Hz / 600V 60Hz 100V 50/60Hz GPAU20LCAA11 GPS1*H and GPS2... 101352 101353 101354 101355 101356 101357 101358 101359 101360 101361 101362 112185 10 10 10 10 10 10 10 10 10 10 10 10 Cat. no. GPS1... and GPS2... 24V 50/60Hz GPASLRAA1 GPS1... and GPS2... 48V 60Hz GPASLRAAF 48V 50Hz / 60V 60Hz GPASLRAAG GPS1... and GPS2... GPS1... and GPS2... 110/127V 50Hz / 120V 60Hz GPASLRAAJ 208V 60Hz GPASLRAAM GPS1... and GPS2... GPS1... and GPS2... 220/230V 50Hz / 240/260V 60Hz GPASLRAAN 240V 50Hz / 277V 60Hz GPASLRAAR GPS1... and GPS2... 380/400V 50Hz GPASLRAAU GPS1... and GPS2... GPS1... and GPS2... 415/440V 50Hz / 460/480V 60Hz GPASLRAAW 500V 50Hz / 600V 60Hz GPASLRAAY GPS1... and GPS2... 24 to 60Vdc GPASLRADD GPS1... and GPS2... 110 to 240Vdc GPASLRADJ GPS1... and GPS2... 100V 50/60Hz GPASLRAA11 GPS1... and GPS2... Undervoltage trip device Description Side mounting on the right Can not be used together with the shunt trip device A B With 2NO early make auxiliary contacts Side mounting on the right Can not be used together with the shunt trip device With 2NO early make auxiliary contacts Side mounting on the right Can not be used together with the shunt trip device C D E F G H For use with Coil voltage Cat. no. GPS1... and GPS2... 24V 50Hz GPAULRAAD GPS1... and GPS2... 24V 60Hz GPAULRAAC GPS1... and GPS2... 48V 50Hz GPAULRAAG GPS1... and GPS2... 48V 60Hz GPAULRAAF GPS1... and GPS2... 110/127V 50Hz / 120V 60Hz GPAULRAAJ GPS1... and GPS2... 208V 60Hz GPAULRAAM GPS1... and GPS2... 220/230V 50Hz / 240/260V 60Hz GPAULRAAN GPS1... and GPS2... 240V 50Hz / 277V 60Hz GPAULRAAR GPS1... and GPS2... 380/400V 50Hz GPAULRAAU GPS1... and GPS2... 415/440V 50Hz / 460/480V 60Hz GPAULRAAW GPS1... and GPS2... 500V 50Hz / 600V 60Hz GPAULRAAY GPS1... and GPS2... 100V 50/60Hz GPAULRAA11 GPS1*S... GPS1*S... GPS1*S... GPS1*S... GPS1*S... GPS1*S... GPS1*S... GPS1*S... GPS1*S... GPS1*S... GPS1*S... GPS1*S... Terminal protector I Description For use with Cat. no. Ref. no. Pack. Snap-in tabs for screw mounting (set of 10) IP20 terminal covers GPS1* GPAKS1A 101509 1 GPS2* GPAPTP2A 107182 50 GPS1* / GPS2* GPS1* / GPS2* GPVDA GPVPA 101514 101515 2 2 DIN rail vibration clamps Panel vibration clamps X 101509 107182 Increases vibration resistance of GPS1* from 5G to 8G (5-150 Hz) in all directions. One clamp must be mounted on each side which increases total mounting width by 22 mm (0.87”). For vibration resistance of GPS2*, contact customers service. Distributed by Electro-Stock, Inc. sales@electrostock.com 630-682-1542 Fax 630-682-1562 http://www.electrostock.com Surion External handle operator Description For use with Type Cat. no. Ref. no. Used for distance mounting on a panel Lockable with 1, 2 or 3 padlocks diameter 4 to 8 mm Two types: standard and emergency applications ON/OFF/TRIPPING position marking Protection degree: IP54 Shaft mounting depths: 139.8 - 289.8 mm for GPA1HAB, GPA1HAR 161 - 311.1 mm for GPA2HAB, GPA2HAR Package parts and quantities: 1 handle unit 1 shaft 1 shaft guide 1 latch (screws) 4 mounting screws GPS1*H... GPS1*H ... GPS2... GPS2 ... Standard (black) Emergency (red/yellow) Standard (black) Emergency (red/yellow) GPA1HAB GPA1HAR GPA2HAB GPA2HAR 101363 101364 101502 101503 For use with Connection Cat. no. Ref. no. Pack. GPS1... Terminal capacity: 25 mm2 Pin Terminal capacity: 50 mm2 Pin GPB1FA 107186 10 GPB2FA 107187 10 Pack. 5 5 5 5 Description 3-phase feed-in terminals Main feeding terminal Upper connection GPS2... Main busbar 63A max. 125A max. Terminal cover type E A GPS1... Terminal capacity: 25mm2 SFVB8 254537 1 Modular spacing 45 mm for 2 GPS1... + frontal auxiliaries for 3 GPS1... + frontal auxiliaries for 4 GPS1... + frontal auxiliaries for 5 GPS1... + frontal auxiliaries Fork Pin Pin Pin Pin GPB1B02A GPB1B03A GPB1B04A GPB1B05A 101390 101391 101392 101393 5 5 5 5 B Modular spacing 54 mm for 2 GPS1... + 9mm lateral aux. for 3 GPS1... + 9mm lateral aux. for 4 GPS1... + 9mm lateral aux. for 5 GPS1... + 9mm lateral aux. Pin Pin Pin Pin GPB1B12A GPB1B13A GPB1B14A GPB1B15A 101394 101395 101396 101397 5 5 5 5 C Modular spacing 63 mm for 2 GPS1... + 18mm lateral aux. or 2 x 9mm lateral auxiliary for 4 GPS1... + 18mm lateral aux. or 2 x 9mm lateral auxiliary Fork GPB1B22A 101398 10 Fork GPB1B24A 101399 10 D Modular spacing 55 mm for 2 GPS2... + frontal auxiliaries for 3 GPS2... + frontal auxiliaries for 4 GPS2... + frontal auxiliaries Pin Pin Pin GPB2B02A GPB2B03A GPB2B04A 101400 101401 101402 1 1 1 Modular spacing 64 mm for 2 GPS2... + 9mm lateral aux. for 3 GPS2... + 9mm lateral aux. for 4 GPS2... + 9mm lateral aux. Pin Pin Pin GPB2B12A GPB2B13A GPB2B14A 101403 101404 101405 1 1 1 for 2 GPS2... + 18mm lateral aux. or 2 x 9mm lateral auxiliary for 4 GPS2... + 18mm lateral aux. or 2 x 9mm lateral auxiliary Pin GPB2B22A 101406 1 Pin GPB2B24A 101407 1 GPS1... GPS1... GPS2... Pin Fork Pin GPB1GA GPB1GAF GPB2GA 101408 101511 101409 10 1 10 GPS1...H - GPAPT1E 107315 1 Modular spacing 73 mm Busbar cover Manual motor starter Busbar system Touch guard for non used space For compliance UL508E When using a Surion GPS1*BH as a manual self-protected combination motor starter (Type E). Cover enables compliance with NEC Section 430-52, 1” over air creepage and over surface clearance, phase to phase on the line side. Distributed by Electro-Stock, Inc. sales@electrostock.com 630-682-1542 Fax 630-682-1562 http://www.electrostock.com E F G H I X Surion Motor protection devices Enclosures for manual motor starters A B C D Product range • Surface and flush mounting plastic enclosures (IP41 and IP55) • Neutral and ground connection • Three different types of push-buttons - Mushroom with impulse function - Mushroom self latching, unlatching by turning - Mushroom self latching, unlatching with a key • Indicator lamps • Padlocking device for three padlocks • Conversion kit IP41 to IP55 E Technical performances F G • Used with GPS1*S manual motor starters • Protection degree IP41 or IP55 • Possibility to mount frontal/lateral auxiliary contact blocks with an undervoltage release (without or with 2NO early make auxiliary contacts) inside the enclosures H I X Distributed by Electro-Stock, Inc. sales@electrostock.com 630-682-1542 Fax 630-682-1562 http://www.electrostock.com Surion Enclosures for only GPS 1*S Ref. no. Pack. Plastic enclosures Surface mounting IP41 Surface mounting IP55 GPES41A GPES55A 101365 101366 1 1 Flush mounting IP41 Flush mounting IP55 GPEF41A GPEF55A 101367 101368 1 1 Cat. no. Ref. no. Pack. To be used inside the enclosure GPENA 101369 1 For enclosures used with GPS1*S and undervoltage release with 2 NO auxiliary contacts GPEUTA 107097 1 For three padlocks with max. 8 mm shackle diameter Not to be used with emergency stop handle GPEPA 101370 1 Mounting accessories for all enclosures Description Neutral connection Adaptor set Manual motor starter Cat. no. Description A Padlocking device B C Conversion kit IP41 to IP55 GPECA 101371 1 D E Mushroom push-button Mushroom spring return Mushroom self latching, turn to release Mushroom self latching, release with a key GPEPMA GPEPLA GPEPKA 101372 101373 101374 1 1 1 F G Indicator lamps Green 110/120V Green 220/240V Green 380/440V Green 480/500V Green 600V Red 110/120V Red 220/240V Red 380/440V Red 480/500V Red 600V Transparent 110/120V Transparent 220/240V Transparent 380/440V Transparent 480/500V Transparent 600V GPELGAJ GPELGAN GPELGAU GPELGAX GPELGAY GPELRAJ GPELRAN GPELRAU GPELRAX GPELRAY GPELCAJ GPELCAN GPELCAU GPELCAX GPELCAY 101375 101376 101377 101378 101379 101380 101381 101382 101383 101384 101385 101386 101387 101388 101389 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Distributed by Electro-Stock, Inc. sales@electrostock.com 630-682-1542 Fax 630-682-1562 http://www.electrostock.com H I X Surion Distributed by Electro-Stock, Inc. sales@electrostock.com 630-682-1542 Fax 630-682-1562 http://www.electrostock.com Technical data General data GPS1 GPS2 690V 690V ac 6kV 50/60Hz 0.16 to 25A 7W 32A 8.5W Cat. A AC3 1000V 690V ac 8kV 50/60Hz up to 32A 11W 40A to 50A 15W 63A 17W Cat. A AC3 100,000 (70,000 for 32A) 100,000 (70,000 for 32A) 25 50,000 25,000 25 -40°C to +80°C -25°C to +60°C -20°C to +60°C yes -40°C to +80°C -25°C to +60°C -20°C to +60°C yes up to 2000m 30g (width 20ms) 8g (5 to 150Hz) up to 2000m 30g (width 20ms) 8g (5 to 150Hz) Shock -hazard prot. (acc.DIN VDE 0106) Protection degree (acc.to IEC529) fingerproof IP20 fingerproof IP10 (IP20 with acc GPAPTP2A) Rated current Ie Overload protection up to 32A IEC 947-4-1 up to 63A IEC 947-4-1 Phase failure protection Tripping class Magnetic release (factory set) Test trip button yes 10 13 x Iemax yes yes 10 13 x Iemax yes Standards & Approvals IEC 947-1 / -2 / -4-1 DIN VDE 0660T 100 / 101 / 102 UL508 UL508 type E CE cULus D / S / N / Fi Shipping approvals yes yes yes Only GPS1*H yes yes In process yes yes yes yes yes yes yes yes 1 x 1...10 mm2 2 x 1...6 mm2 1 or 2 x 1...6 mm2 1 x 18…8 / 2 x 18…10 3.5 to 4.5 1 or 2 x 1...25 mm2 1 x 1…25 mm2 / 2 x 1…16 mm2 1 x 18…2 / 2 x 18…4 3.5 to 4.5 screw 2 Nm / 18Lb.in Pz2 / slotted combination box 5 Nm / 45 Lb.in Pz2 / slotted combination yes no yes yes 30° 90° 180° 30° 90° 180° Rocker level / Rotary Rotary 45 90 (GPS1*S) 75 / 92.5 (GPS1*H) 55 120 107.5 Motor protection devices Frame size A B C D E F G H I X Rated insolation voltage Ui Rated operating voltage Ue Rated impulse withstand strength Uimp Rated frequency Total power loss P (W) Utilisation category: IEC 947-2 (Circuit breaker) IEC 947-4-1 (Motor starter) Mechanical operational performance Electrical operational performance Max.operations per hour (motor start-up) Ambient conditions: Storage temperature Operation temperature Temperature compensation Ambient temperature compensation Operational altitude Shock resistance (IEC 68) Vibration resistance Mounting data Terminal capacity: Solid or stranded without end sleeve Stranded with end sleeve AWG Operating mechanism lockable in OFF position diameter (mm) Terminal type Tightening torque Screwdriver Mounting: DIN-rail Screws Operating position: turning to the front turning to the back turning to both sides Handle operation Dimensions width (mm) height (mm) depth (mm) Surion Distributed by Electro-Stock, Inc. sales@electrostock.com 630-682-1542 Fax 630-682-1562 http://www.electrostock.com Ultimate short-circuit breaking capacity (Icu) in kA For ranges GPS1BSA* / GPS1MSA* Rated current (A) 220/230V 400/415V 440V 500/525V 600V 690V A 1.6 100 100 100 100 100 100 B 0.25 100 100 100 100 100 100 C 0.4 100 100 100 100 100 100 D 0.63 100 100 100 100 100 100 E 1 100 100 100 100 100 100 F 1.6 100 100 100 100 100 100 G 2.5 100 100 100 100 3 3 H 4 100 100 100 100 3 3 J 6.3 100 100 50 50 3 3 K 10 100 100 15 10 3 3 L 13 100 50 10 6 3 3 M 16 100 25 10 6 3 3 P 25 50 25 10 6 3 3 R 32 50 25 10 6 3 3 S 40 - T 50 - U 63 - 100 50 35 10 4 4 100 50 35 10 4 4 100 50 35 10 4 4 100 50 35 10 4 4 - - - 100 25 10 6 4 4 50 25 10 6 4 4 50 25 10 6 4 4 50 25 10 6 4 4 50 25 10 5 4 4 50 25 10 5 4 4 50 25 10 5 4 4 100 50 50 12 5 5 100 50 35 12 5 5 100 50 35 10 5 5 100 50 35 10 5 5 100 50 35 10 5 5 100 50 35 10 5 5 For ranges GPS1BHA* / GPS1MHA* 220/230V 400/415V 440V 500/525V 600V 690V 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 8 8 100 100 100 100 8 8 100 100 100 100 6 6 100 100 50 50 6 6 100 100 50 42 6 6 For ranges GPS2BSA* / GPS2MSA* 220/230V 400/415V 440V 500/525V 600V 690V - - - - - - - - - 100 100 15 10 4 4 100 50 10 6 4 4 Manual motor starter N 20 50 25 10 6 3 3 For ranges GPS2BHA* / GPS2MHA* 220/230V 400/415V 440V 500/525V 600V 690V - - - - - - - - - 100 100 50 50 6 6 100 100 50 42 6 6 100 50 50 12 5 5 Short-circuit proof with an Icu = 100kA or 50kA A B C Rated service short-circuit breaking capacity (Ics) in kA For ranges GPS1BSA* / GPS1MSA* Rated current (A) 220/230V 400/415V 440V 500/525V 600V 690V A 1.6 100 100 100 100 100 100 B 0.25 100 100 100 100 100 100 C 0.4 100 100 100 100 100 100 D 0.63 100 100 100 100 100 100 E 1 100 100 100 100 100 100 F 1.6 100 100 100 100 100 100 G 2.5 100 100 100 100 3 3 H 4 100 100 100 100 3 3 J 6.3 100 100 38 38 3 3 K 10 100 100 11 8 3 3 L 13 100 38 8 5 3 3 M 16 100 19 8 5 3 3 N 20 38 19 8 5 3 3 P 25 38 19 8 5 3 3 R 32 38 19 8 5 3 3 S 40 - T 50 - U 63 - 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 6 6 100 100 100 100 6 6 100 100 100 100 5 5 100 100 38 38 5 5 100 100 38 32 5 5 100 38 25 8 3 3 100 38 25 8 3 3 100 38 25 8 3 3 100 38 25 8 3 3 - - - - - - - - - - - - 100 100 12 8 3 3 100 32 8 5 3 3 100 19 8 5 3 3 38 19 8 5 3 3 38 19 8 5 3 3 38 19 8 5 3 3 38 19 8 4 3 3 38 19 8 4 3 3 38 19 8 4 3 3 - - - - - - - - - 100 100 38 38 5 5 100 100 38 32 5 5 Back-up fuses are necessary in case of possibility of a short-circuit current higher than 100kA or 50kA at the installation point of the device (on request) Ics = 100%Icu when Icu = 100kA Ics = 75%Icu when Icu < 100kA 100 38 38 9 4 4 I X For ranges GPS2BHA* / GPS2MHA* 220/230V 400/415V 440V 500/525V 600V 690V G H For ranges GPS2BSA* / GPS2MSA* 220/230V 400/415V 440V 500/525V 600V 690V E F For ranges GPS1BHA* / GPS1MHA* 220/230V 400/415V 440V 500/525V 600V 690V D 100 38 38 9 4 4 100 38 25 9 4 4 100 38 25 8 4 4 100 38 25 8 4 4 100 38 25 8 4 4 100 38 25 8 4 4 Surion Distributed by Electro-Stock, Inc. sales@electrostock.com 630-682-1542 Fax 630-682-1562 http://www.electrostock.com Back-up gl/gG fuses only if Ics > Icu (kA) Motor protection devices For ranges GPS1BSA* / GPS1MSA* gl/gG fuses (A) 230V 400V 440V 500V 600V 690V A 1.6 # # # # # # B 0.25 # # # # # # C 0.4 # # # # # # D 0.63 # # # # # # E 1 # # # # # # F 1.6 # # # # # # G 2.5 # # # # 20 20 # # # # # # J 6.3 # # 50 50 40 40 K 10 # # 63 50 50 50 L 13 # 80 63 63 63 50 M 16 # 100 80 63 63 63 N 20 100 100 80 63 63 63 P 25 100 100 80 80 80 63 R 32 100 100 80 80 80 63 S 40 - T 50 - U 63 - # 100 80 80 63 63 # 125 80 80 63 63 # 125 100 80 80 63 # 125 100 80 80 63 - - - # 100 80 80 63 63 125 125 80 80 63 63 125 125 100 80 80 63 125 125 100 80 80 63 125 125 125 100 100 63 125 125 125 100 100 80 160 160 125 125 100 100 # 125 80 80 63 63 # 125 100 80 80 63 # 125 100 80 80 63 # 125 125 100 100 63 # 125 125 100 100 80 # 160 125 125 100 100 For ranges GPS1BHA* / GPS1MHA* GPS1*H 230V 400V 440V 500V 600V 690V H 4 # # # # 32 32 # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # 25 25 # # # # 40 40 # # # # 50 50 # # 63 50 50 50 # # 63 63 63 63 For ranges GPS2BSA* / GPS2MSA* 230V 400V 440V 500V 600V 690V - - - - - - - - - # # 63 63 63 63 # 80 63 63 63 63 For ranges GPS2BHA* / GPS2MHA* A B 230V 400V 440V 500V 600V 690V - - - - - - - - - # # 63 63 80 80 # # 63 63 63 63 # 100 80 80 63 63 C Back-up gl/gG fuses only if Ics > Icu (kA) D E F G H I X Manual motor starter: GPS1... Manual motor starter: GPS2... Surion Distributed by Electro-Stock, Inc. sales@electrostock.com 630-682-1542 Fax 630-682-1562 http://www.electrostock.com Specific let-through energy at Ue = 400/415 V Manual motor starter: GPS1... Manual motor starter: GPS2... Manual motor starter A B C Peak current limitation at Ue = 400/415 V Manual motor starter: GPS1... Manual motor starter: GPS2... D E F G H I X Surion Motor protection devices Mounting possibilities of the auxiliaries Wiring diagram Frontal auxiliaries Type Description Auxiliary contact block 1NO or 1NC Two frontal auxiliary contact blocks can be installed at the same time maintaining the overall width of the manual motor starter. Alarm contact block 1NO or 1NC Installed on the frontal right side. Can be mounted in combination with the frontal auxiliary block. The overall width of the manual motor starter is maintained. Auxiliary contact block 2NO 1NO + 1NC 2NC Different catalogue numbers for left or right mounting. Maximum number of auxiliary contact blocks mounted on each side: 2. Total number of auxiliary contacts in combination frontal and lateral: 8. Width of each lateral auxiliary contact block: 9 mm. GPS1 rated at 32A allows maximum 2 auxiliary contact blocks (4 contacts). Auxiliary/alarm contact block 1NO (alarm) + 1NO (auxiliary) 1NO (alarm) + 1NC (auxiliary) 1NC (alarm) + 1NO (auxiliary) 1NC (alarm) + 1NC (auxiliary) Installed on the left side. Maximum number of blocks per manual motor starter: 1. Can be fitted together with one lateral auxiliary contact block or one shortcircuit alarm block mounted on the left side. Width of each lateral alarm/auxiliary contact block: 9 mm. Short-circuit alarm contact block 1NO + 1NC A Lateral auxiliaries B C D E F G Installed on the left side. Tripping in case of short-circuit only. Can be fitted together with one lateral auxiliary contact block or one auxiliary/ alarm block mounted on the left side. Width of each short-circuit alarm contact block: 9 mm. Shunt trip Installed on the right side. Can not be mounted together with the undervoltage release or any lateral block mounted on the same side. Width of each shunt trip: 18 mm. Undervoltage trip Installed on the right side. Can not be mounted together with a shunt trip device or any lateral block mounted on the same side. Width of each undervoltage trip: 18 mm Undervoltage trip with 2NO early make auxiliary contacts Installed on the right side. Two different types, one for the GPS1*S.. and another for the GPS1*H..and GPS2.. Can not be mounted together with a shunt trip device or any lateral block mounted on the same side. Width of each undervoltage trip: 18 mm. H I X Shunt trip, undervoltage trip and undervoltage with 2NO contacts can be mounted together with any frontal block or left lateral block with above mentioned restrictions Distributed by Electro-Stock, Inc. sales@electrostock.com 630-682-1542 Fax 630-682-1562 http://www.electrostock.com Surion Auxiliaries Catalogue reference Cont. cap. contacts class (UL508) Back-up fuses gG, gl GPAC*F.. Aux. frontal block GPAC*L.. Aux. lateral block GPAL.. Alarm frontal block GPAD.. Alarm/aux. lateral block GPAE.. Short-circuit alarm block B300 / Q300 A600 / P300 B300 / Q300 A600 / P300 A600 / P300 6A 10A 6A 10A 10A Utilization category AC-15 Rated operating voltage Ue (Vac) 48 125 230 48 125 230 400 500 690 48 125 230 48 125 230 400 500 690 48 125 230 400 500 690 Rated operational current (A) 5 3 1.5 6 4 4 2.2 1.5 0.6 5 3 1.5 6 4 4 2.2 1.5 0.6 6 4 4 2.2 1.5 0.6 Mounting side Front Terminals capacity: Solid or stranded without end sleeve 2x0.5…2.5 mm2 AWG 2x18…14 Terminal type screw Tightening torque 0.8Nm Screwdriver Pz2/Slotted Dimensions width (mm) Maintain same width 48 5 110 1.3 220 0.5 Utilization category DC-13 48 110 220 48 110 1.38 0.55 0.27 5 1.3 Mounting data Frontal right Left or right 2 2 220 0.5 48 5 110 1.3 Left 220 0.5 Left 2 2x0.5…2.5 mm 2x18…14 screw 0.8Nm Pz2/Slotted 2x0.5…2.5 mm 2x18…14 screw 0.8Nm Pz2/Slotted 2x0.5…2.5 mm 2x18…14 screw 0.8Nm Pz2/Slotted 2x0.5…2.5 mm2 2x18…14 screw 0.8Nm Pz2/Slotted Increase width 9 mm Maintain same width Increase width 9 mm Increase width 9 mm Manual motor starter Rated operating voltage Ue (Vdc) 48 110 220 Rated operational current (A) 1.38 0.55 0.27 Detailed dimensions see page B.29 A Auxiliaries Catalogue reference Power consuption: Pick-up (VA/W) Hold (VA/W) Operating voltage Tripping (V) Pick-up (V) Max. operation supply (ms) Rated operating voltage Ue Contacts class (UL508) Back-up fuses (gG,gI) GPAU Undervoltage trip GPAS Shunt trip 21/12 8/1.2 21/12 - 0.35Ve-0.7Ve 0.85Ve-1.1Ve - 0.7Ve-1.1Ve 5(DC) 24V 50Hz 24V 60Hz 48V 50Hz 48V 60Hz 110/127V 50Hz / 120V 60Hz 208V 60Hz 220/230V 50Hz / 240/260V 60Hz 240V 50Hz / 277V 60Hz 380/400V 50Hz 415/440V 50Hz / 460/480V 60Hz 500V 50Hz / 600V 60Hz 24V 50/60Hz 48V 60Hz 48V 50Hz / 60V 60Hz 110/127V 50Hz / 120V 60Hz 208V 60Hz 220/230V 50Hz / 240/260V 60Hz 240V 50Hz / 277V 60Hz 380/400V 50Hz 415/440V 50Hz / 460/480V 60Hz 500V 50Hz / 600V 60Hz 24 to 60Vdc 110 to 240Vdc 10A 10A Dimensions width (mm) C D E F G Mounting data Mounting side Terminals capacity: Solid or stranded without end sleeve AWG Terminal type Tightening torque Screwdriver B Right Right 2x0.5…2.5 mm 2x18…14 Screw 0.8Nm Pz2/Slotted 2x0.5…2.5 mm2 2x18…14 Screw 0.8Nm Pz2/Slotted Increase width 18 mm Increase width 18 mm 2 H I X Distributed by Electro-Stock, Inc. sales@electrostock.com 630-682-1542 Fax 630-682-1562 http://www.electrostock.com Surion Distributed by Electro-Stock, Inc. sales@electrostock.com 630-682-1542 Fax 630-682-1562 http://www.electrostock.com Dimensional drawings Motor protection devices Manual Motor Starter - GPS1 rocker A Manual Motor Starter - GPS1 rotary B C D E F Manual Motor Starter - GPS2 G H I X Surion Distributed by Electro-Stock, Inc. sales@electrostock.com 630-682-1542 Fax 630-682-1562 http://www.electrostock.com Auxiliary contact blocks Frontal Auxiliary contact blocks Lateral Manual motor starter Alarm contact blocks Frontal Alarm contact blocks Lateral A B C D E F Shunt and undervoltage trip devices Short-circuit contact block G H I X Surion Distributed by Electro-Stock, Inc. sales@electrostock.com 630-682-1542 Fax 630-682-1562 http://www.electrostock.com Dimensional drawings Motor protection devices GPS1 rocker + Undervoltage trip device with 2NO contacts GPS1 rocker + Auxiliaries A B C GPS1 rotary + Auxiliaries D E F G H I X GPS2 + Auxiliaries Surion External handle operator Manual motor starter Load side A B Type Applicable frame C D E F G H I X Distributed by Electro-Stock, Inc. sales@electrostock.com 630-682-1542 Fax 630-682-1562 http://www.electrostock.com Surion Distributed by Electro-Stock, Inc. sales@electrostock.com 630-682-1542 Fax 630-682-1562 http://www.electrostock.com Dimensional drawings Motor protection devices Enclosure for GPS1 - Surface mounting A B C D Enclosure for GPS1 - Surface mounting with padlocking device Padlocking device E locked F G H I X unlocked Surion Enclosure for GPS1 - Surface mounting with emergency push-button Manual motor starter A B C D E F G H I X Distributed by Electro-Stock, Inc. sales@electrostock.com 630-682-1542 Fax 630-682-1562 http://www.electrostock.com Surion Distributed by Electro-Stock, Inc. sales@electrostock.com 630-682-1542 Fax 630-682-1562 http://www.electrostock.com Dimensional drawings Motor protection devices Enclosure for GPS1 - Flush mounting A B C Enclosure for GPS1 - Flush mounting with padlocking device D Padlocking device locked E F G H I X unlocked