EWC485 Range Test

advertisement
EWC485 Range Test
Stronger Signal
Less Interference
1
The processor MUST have this sticker to
use the wireless communicator.
Firmware version 6.11 or later.
WIRELESS
communicator
Compatible
2 Screw antennas on TIGHT.
WIRE
com
LESS
mu
Compnicator
atible
Loose antennas will affect the signal strength!
3 Unlock the units and open doors.
4 Set both units to TEST MODE.
ONLY test 2 units at a time, turn ALL other units OFF!
5 Set one unit to LOCAL connection and the other to REMOTE connection. The “LOCAL
More Interference
Weak Signal
connection” unit is near the telephone entry system.
6 Temporarily stick the supplied battery packs on the outside of each unit with the double stick
tape. Feed the wires through an existing hole on back of the unit. It is VERY important that BOTH
battery packs produce 12 Vdc, weak batteries will produce undependable test results.
If a continuous tone is NOT heard during the range test:
7 Both units must be set to the same FACILITY FREQUENCY. If they are not the same,
follow Step 55 on the manual to set the frequencies on both units.
Make sure the antennas are screwed on tight.
8 Connect the battery wires to the removable power connector. When BOTH
Try moving the remote unit 15-20 feet in several directions, away from metal surfaces or any obstructions.
units have been powered up, a CONTINUOUS tone will be heard from both
units indicating strong signals are being transmitted
and received.
Try moving the local unit 15-20 feet in several directions.
Try raising the units up, above the rooftops if necessary to clear any obstacles. The higher the units, the
less interference they will encounter. Keep antenna clear from metal surfaces or any obstructions that can
weaken the signal strength.
9 Close and lock the units placing the LOCAL unit in
its final position near the telephone entry system.
Recommend minimum 8 feet above ground.
10 Take the REMOTE unit to the desired remote access
Test the battery packs with a voltmeter for 12 Vdc. Weak batteries will produce undependable test results.
Part Number 41A6082
Try changing the FACILITY FREQUENCY of the units. Follow Step 55
5 on the manual. Both units MUST be
set to the same frequency.
point and place it in its final position.
A continuous tone should be heard indicating that the range is OK.
The units can now be permanently installed in their current
positions.
Use the supplied transformer for permanent power. Discard battery pack.
If a continuous tone is not achieved after all previous suggestions have been tried,
call for toll free technical support: 1-800-582-2806
11 Set the units back to OPERATING MODE.
4
5
EWC485 Installation
Optional Antenna Cover
Protects against vandalism.
Part Number 41A6083
Daisy Chain RS485 Devices Together
To Next
RS485 Device
Use Separate Transformer
12 Vac, 20VA
+ – Gnd
POWER INPUT
SURGE SUPPRESSOR
®
Elite Entry Phone
RS485
eliteentryphone.com
SURGE SUPPRESSOR
POWER INPUT
SURGE SUPPRESSOR
P/N: TAPISS
14“
OUT
RS-485 (+)
IN
BROWN: RS-485 (+)
RS-485 (-)
BLUE: RS-485 (-)
RS-485 GND
YELLOW: RS-485 GND
GREEN: CHASSIS GND
7“
+ – Gnd
3.25“
Sample Mountings
12 AWG Wire
Use Provided
Transformer
12 Vac, 20VA
1.8“
4.25“
Wiring 1 RS485 Device
Back View
Use Separate Transformer
12 Vac, 20VA
Suggestion:
Seal holes of box
with sealant when
finished wiring.
Do not share
transformer with any
other devices.
POWER INPUT
SURGE SUPPRESSOR
®
Elite Entry Phone
RS485
22 AWG
Shielded Wire
eliteentryphone.com
SURGE SUPPRESSOR
POWER INPUT
SURGE SUPPRESSOR
P/N: TAPISS
OUT
+
–
Gnd
RS-485 (+)
IN
BROWN: RS-485 (+)
RS-485 (-)
BLUE: RS-485 (-)
RS-485 GND
YELLOW: RS-485 GND
GREEN: CHASSIS GND
Mounting Bolt Clearance
RS485 Wire Run
BUILT-IN
SURGE PROTECTION
.66“
12 AWG Wire
3 Feet Max.
WIRELESS
communicator
Compatible
WIRE
com
LESS
mun
Com
icat
patibleor
12 AWG Wire
Processor MUST have this sticker to use the wireless communicator.
Firmware version 6.11 or later.
3“
Side View
The earth ground rod must be
located within 3 feet from the
wireless communicator.
Make sure the unit is set
to OPERATING MODE.
114A2969B
Call for toll free technical support: 1-800-582-2806
© 2011 The Chamberlain Group, Inc.
All Rights Reserved
845 Larch Avenue Elmhurst, Illinois 60126-1196
Download