Heavy-Duty Commercial Gas Tankless Water Heaters TANKLESS HEAVY-DUTY COMMERICAL MODELS Fully modulating, gas-fired, tankless water heaters specifically designed for heavy-duty commercial applications. Can be installed either outdoors, indoors, or direct vented. Capable of supplying domestic hot water systems and/or combined domestic and heating applications (local codes dictate proper compliance). Multiple units can be combined in a system of water heaters to provide for larger applications such as hotels, large restaurants and apartment complexes. FEATURES PRIMARY HEAT EXCHANGER IS CONSTRUCTED OF HRS35 COMMERCIALGRADE COPPER ■ Stronger than standard copper and more resilient against erostion CONTINUOUS MAXIMUM FLOW RATES UP TO 9.0 GPM EASY-LINK UP TO 4 UNITS ■ Multi-link up to 20 units with TM-MC01 (no multiple controller needed) COMBINED INDOOR/OUTDOOR MODELS AVAILABLE IN NATURAL GAS OR PROPANE (LP) ASME MODELS AVAILABLE LOW NOx EMISSIONS COMPLIES WITH LEAD FREE STANDARDS SAFETY FEATURES: ■ ■ ■ ■ ■ ■ ■ ATIO-710-N ATIO-710-P ATIO-710-AN ATIO-710-AP Built in Freeze Protection Manual Reset Hi Limit (Set at 194°F Overheat Cutoff Fuse Inlet, Outlet & Mixing Thermistors for Constant Temperature Monitoring Air Fuel Ratio Rod GFI Fuse & Surge Absorber Power Supply Connection VENTING AND COMBUSTION ■ ■ ■ ■ ■ ■ 4” Category III Stainless Steel Vertical or Horizontal Installation 50’ Max Length, 5 elbows max (90° elbows=5’ equivalent length) Power Vent Electronic Ignition - No Pilot Light 4” Combustion Air Intake (with optional kit) ANSI Z21.10.3 CSA 4.3 OPTIONAL ACCESSORIES ■ ■ ■ ■ ■ ■ Multi-Unit Controller (Multi-Unit System) Remote Temperature Controller Direct Vent Conversion Kit Pipe Cover Vent Cap Backflow Prentor WARRANTY ■ 10-year limited warranty on heat exchanger in commercial applications ■ 5-year warranty on all parts Page 1 of 2 Revised February 2013 254188_AOSCG14000.indd 1 AOSCG14000 2/15/13 1:08 PM Heavy-Duty Commercial Gas Tankless Water Heaters TANKLESS HEAVY-DUTY COMMERICAL MODELS GAS CONSUMPTION INPUT MODEL NUMBER INLET GAS PRESSURE FUEL TYPE MIN. BTU/H MAX. BTU/H THERMAL MIN. MAX. EFFICIENCY W.C. W.C. ATIO-710-N Natural 24,000 240,000 82% 5.0 ATIO-710-P Propane 24,000 240,000 84% DIMENSIONS (INCHES) INTAKE HOT/COLD FLUE*** (OPTIONAL) GAS CONN. APPROX. SHIPPING WEIGHT (LBS) GPM** HEIGHT WIDTH DEPTH VOLT AMP 10.5 0.5 - 9.0 23-5/8 18-1/2 8-7/8 120 0.94 4” O.D. 4” O.D. 3/4” NPT 66 8.0 14.0 0.5 - 9.0 23-5/8 18-1/2 8-7/8 120 0.94 4” O.D. 4” O.D. 3/4 ” NPT 66 ATIO-710-AN* Natural 24,000 240,000 82% 5.0 10.5 0.5 - 9.0 23-5/8 18-1/2 8-7/8 120 0.94 4” O.D. 4” O.D. 3/4 ” NPT 66 ATIO-710-AP* Propane 24,000 240,000 84% 8.0 14.0 0.5 - 9.0 23-5/8 18-1/2 8-7/8 120 0.94 4” O.D. 4” O.D. 3/4 ” NPT 66 All dimensions in inches. 15-150 psi water pressure. 40 psi or above recommended for maximum flow. * ASME models **Current numbers based on factory testing, 0.4 GPM required for continuous fire after initial ignition. ***Category III required Pressure only relief valve requires (Min. 240,000 BTUs. 150 PSI). Min 40 PSI or above recommended for maximum flow. CLEARANCES: INDOOR: Top 12”, Bottom 12”, Front 24”, Back 1”, Sides 2” OUTDOOR: Top 36”, Bottom 12”, Front 24”, Back 1”, Sides 2” Flow Rate Vs. Temperature Rise 10.0 9.0 Flow Rate (gpm) 8.0 18-1/2” (470mm) 15-3/4” (399mm) 7” (179mm) 7.0 8-7/8” (226mm) 6.0 5.0 4-1/2” (114mm) 4.0 3.0 2.0 1.0 0.0 0 20 40 60 80 100 120 140 Temperature Rise (°F) Pressure Drop 60 25 50 20 40 15 30 10 20 5 10 0 0 0.0 2.0 4.0 6.0 8.0 10.0 Flow Rate (gpm) Set temperature of 145° or lower Set temperature of 150° or higher Head Feet Pressure Loss (psi) 30 24-5/8” (626mm) Set temperature of 150° or higher 23-5/8” (600mm) Set temperature of 145° or Lower Above shown rate is based on single unit only 1-1/8” (27.8mm) 3-1/8” (80.8mm) 4-5/8” (118.3mm) 6-1/4” (159mm) 1-5/8” (42mm) 120v 1-1/2” (40.9mm) COLD 5-7/8” (149mm) HOT 5-7/8” (147mm) GAS Specification Water heater(s) shall be Model _________________ as manufactured by A. O. Smith. The water heater(s) shall be a copper coil integral fin and tube construction with quick release brass or bronze waterways. Heater(s) will be factory assembled and tested. The heater shall be vented with 4” Stainless steel Category III vent pipe a distance not to exceed 50’ (equivalent) feet terminating vertically or horizontally as prescribed. Intake air with optional direct vent kit may be of such material as PVC not to exceed a total of 50’ (equivalent). The heater(s) shall be controlled by onboard solid state printed circuit board monitoring incoming and outgoing temperatures with factory-installed thermistors, sensing and controlling flow rate to set point temperature with control both air and gas mixture inputs to maintain thermal combustion efficiency. Unit also consists of ground fault interrupter, inline fusing, spark ignition and sensor system, aluminized stainless steel burners, air-fuel ratio rod, Hi limit switch, modulating and proportional gas valves, freeze protection sensor and heating block and overhead cutoff fuses. The water heater(s) shall be CSA listed, meets the energy efficiency requirements of ASHRAE 90. 1b-1992 and complies with SCAQMD rule 1146.2 and other air quality management districts with similar requirements for low NOx emissions. For Technical Information call 1-877-737-2840. A. O. Smith Corporation reserves the right to make product changes or improvements without prior notice. Revised February 2013 www.hotwater.com 254188_AOSCG14000.indd 2 Page 2 of 2 AOSCG14000 2/15/13 1:08 PM