DTAV40VM Series Defrost Timer Project: DTAV40VM Series Location: Auto-Voltage Defrost Timer with Voltage Monitoring and Short Cycle Product Type: The Grässlin DTAV40VM Series Auto Voltage Defrost Timer with Voltage monitoring is applicable to air defrost (compressor shutdown) and electric or hot gas defrost systems where defrost is terminated by the timer. If the coil is frost free, the timers can also be terminated by temperature or pressure switches before the programmed defrost termination time has been reached. The time termination functions as a fail-safe and terminates the defrost cycle if the temperature or pressure switch fails to do so. With built in voltage monitoring and short cycle delay options the DTAV40VM further increases system life by protecting the compressor. Model #: Contact/Phone: Features • Voltage monitoring protects against low voltage conditions (Brown outs) • DTAV40VM replaces over 40 competitive models • Adjustable short cycle delay helps extend compressor life • Auto-Voltage adjusts for 120-240 VAC • Mounts in existing enclosures, no tools required • Captive trippers cannot be lost • UL Type 3R outdoor enclosure • Moisture resistant conformal coated board • LED indicators for defrost and refrigeration cycles • Defrost cycles are programmed independently • "Real-time" clock face for quick, easy and accurate setting • Min ON/OFF time: 15 minutes • Max ON/OFF time: 23 hours, 45 minutes DTAV40VM Inside Ratings Input Voltage: Auto-Voltage 120-240 VAC, 60 Hz Electrical Ratings: 40 Amp Resistive, 120-240 VAC 1 HP, 120 VAC 2 HP, 240 VAC Operating Temperature: -40º F to 104º F (-40ºC to 40ºC) Operating Humidity: 0-95% RH, non-condensing Enclosure: UL Type 3R Min ON/OFF: 15 minutes Max ON/OFF: 23 hours, 45 minutes Short cycle Delay:0, 6 second, 30 second, 1, 2, 4, 6, 8, 10 minute Voltage Protection:< 95 VAC for 120 VAC & <190 VAC for 240 VAC (+/- 2 VAC) Electrical Life: 50,000 Operations at full load Wire Size: AWG #8 Shipping Weight: 1.95 lbs. Warranty: Limited 1 year DTAV40VM HVACR #E10694 Energy Controls DTAV40 Series Model Number Voltage Enclosure Timing DTAV40VM 120-240 VAC UL Type 3R Raintight plastic 24-Hour, 15-minute Intervals Specification Furnish and install a Grässlin___________defrost control, which will automatically adjusts between 120 VAC and 240 VAC operation. The defrost timer shall have defrost initiation times settable in 15-minute intervals with captive trippers. The defrost timer shall incorporate voltage monitoring to protect against low voltage conditions. The defrost timer shall also incorporate a short cycle delay adjustable from 0sec (off), 6sec. minimum to 10min. max to prevent rapid compressor cycling. The defrost timer shall be housed in a UL Type 3R indoor/outdoor plastic enclosure. The relay output shall be rated for 40A Resistive, 2 HP @ 240 VAC. Defrost termination to be by time (or by a remote temperature or pressure switch). Diagrams Energy Controls 6.61" [16.79 cm] 5.73" [14.55 cm] 8143 Replacement CONTROL POWER TERMINATE INPUT 8.88" [22.56 cm] 1 3 N 2 4 X 8143 LABEL L1 LINE FAN HOT GAS VALVE TERMINATION THERMOSTAT W/FAN DELAY CONNECT ACROSS COMPRESSOR THERMOSTAT L2 3" [7.62 cm] 8145 Replacement Mode A - No Label Required 8045 Replacement CONTROL POWER F 3 1-N L1 2 4 THERMOSTAT DEFROST HEATER LINE COMPRESSOR OR SOLENOID VALVE OR CONTACTOR COIL TERMINATE INPUT X CONTROL TERMINATE POWER INPUT 8045 LABEL F 2 4 N X THERMOSTAT DEFROST HEATER LINE TERMINATION THERMOSTAT W/FAN DELAY FAN MOTOR COMPRESSOR OR SOLENOID VALVE OR CONTACTOR COIL L2 8041 Replacement N 1 3 L1 2 LINE DEFROST HEATER 8141 Replacement Mode A with 8141 Terminal Block Label Applied CONTROL TERMINATE POWER INPUT 4 THERMOSTAT L2 1 L1 FAN MOTOR L2 FAN 3 COMPRESSOR OR SOLENOID VALVE OR CONTACTOR COIL X CONTROL POWER 8041 LABEL N 1 3 2 4 X TERMINATE INPUT 8141 LABEL THERMOSTAT L1 FAN LINE L2 www.intermatic.com DEFROST HEATER COMPRESSOR OR SOLENOID VALVE OR CONTACTOR COIL TERMINATION THERMOSTAT W/FAN DELAY