TABLE OF CONTENTS Overhead Meters D726 Consumer Service Pole for Mobile Home Park D727 Temporary Service 3-wire Single Phase D731.1 Overhead Meter Installation - Single Phase D731.2 Connection Diagram - Single Phase D731.3 Connection Diagram – Single Phase D732 Meter Installation for Self-contained, Poly-phase Meter D732.2 Meter Installation for Self-contained, 3-phase Meter D732.3 Service Entrance and Outdoor Metering Installation Above 200A D732.4 480V Consumer Service Pole D733 Consumer Service Pole -200 Ampere Maximum per Meter Underground Services U701 Underground Service - Recommend Sizes U702 Customers Bus Entrance for Transformer vaults U704 Underground Service - Preferred Routing and Point of Service Underground Meters U762 Multiple Meter Installation - 200 Amperes Per Position -Single Phase, Self-contained U762.1 Connection Diagram for Multiple Meter Installation -Single Phase, Self-contained U762.3 Connection Diagram -Single Phase - 200 Ampere U762.4 Connection Diagram Single Phase - 320 Ampere Maximum U762.9 Connection Diagram for Three Phase 320A Maximum U765 Meter Installation for Current Transformer Metering Single or Three Phase 1200A Max. U765.1 Connection Diagram for Three Phase CT Meter Installation U771 Temporary Service – 3 Wire, Single Phase 240/120 Volts U772 Meter Installation - Self-contained, 3-phase or Single Phase, 200 Ampere Max. U772.2 Connection Diagram - Self-contained 3 Phase 4 wire meter 208Y/120 or 240Delta /120 volt 200-Amp Max U773.3 Group Meter Installation - Self-contained, 3-phase, 200A per Position, 120/240 or 120/208Y Volts U773.6 CT Metering Components Installation Instructions One Customer and CT's in Transformer U773.7 Meter Installation for Self Contained Single Phase Meter 240/120 Volts 200A Max. U773.8 Meter Installation for self-contained meters 240/480Delta, 480Y/277 or 480-volt Two-wire 200-Amp Max. U773.9 Connection Diagram for Self-Contained single phase 480-volt Two-Wire Service 200-Amp Max © OG&E Electric Services Overhead Signatures on File APPROVED SUPERSEDES FEB 2007 ISSUE 7 5-ft minimum 48 to 66-inches Furnished by Item Meter base 100A 281047 200A 281065 60-inches preferred 24 30-in 5 Notes: Schedule A. No distinction shall be made 6 40 PVC between a mobile home that has or better its wheels removed or one that is 2 still mobile by virtue of being on a wheeled chassis 4 B. The service equipment shall be installed adjacent to the mobile 9 home in all cases C. Meter pole location to be approved by OGE 3 D. Total length of pole is to be a minimum of 20 feet and diameter 10 See note D of pole at ground line is to be a minimum of 7-inches. E. 12-ft over areas restricted to pedestrians or other traffic less than 8-ft in height. 16-ft over areas subject to any traffic greater than 8ft. in height For swimming pools see D262.4 or D262.6. 11 For other situations see D262, D262.1, D262.3 or D262.5 1 12-ft minimum or greater as required to comply with note E 8 no. D726 DISTRIBUTION STANDARD DEC 2007 Installed by Description O.G.E. Consumer O.G.E. Consumer 1 Service head X X 2 Service pole See note D X X 3 Service equipment X X 4 Meter base 5 Service entrance conductor X X 6 Service raceway X X 7 Service drop bracket X 8 Service drop X X 9 Meter X X 10 11 See note D © See note E for minimum clearance to bottom of drip loop and service drop cables (open wire service may require greater clearances). The following is a suggested configuration for meter bases for overhead and underground meters in residential and commercial applications. OG&E Energy Corp., its subsidiaries and affiliates disclaim any liability for the construction or maintenance practices relating to such suggested configuration. OG&E Electric Services Grounding electrode Conductor Grounding electrode X X X X X X X Pressure treated southern yellow pine CONSUMER SERVICE POLE FOR MOBILE HOME PARK 200-AMPERE MAXIMUM PER METER ® D727 © DISTRIBUTION STANDARD AUG 2007 6-inch (min) To OG&E pole TOP VIEW 7 24-inch Lead 4 5 Metal or Nonmetallic conduit (Schedule 40PVC or Better) 6 Install 2 x 4 (min) Pole Brace if Required by OG&E Meter Base 100A 281047 200A 281065 1 Cross Braces 2 x 4 (min) 48 to 66-inches 60-inch Preferred 2 11 3 8 Stakes 2 x 4 (min) Preferred Pole Size 20-Ft with a 7-inch min. Diameter at Ground Line 9 4-Ft (min) See note A for minimum to Drip Loop and service drop cables (open wire services may require greater clearance) * NOTE: A. 12-ft over areas restricted to pedestrians or other traffic less than 8-ft in height. 16-ft over areas subject to any traffic greater than 8ft. in height. For swimming pools see D262.4 or D262.6. For other situations see D262, D262.1, D262.3 or D262.5. 10 * Refusal to attach service to inadequate structure is determined by OG&E installer based on but not limited to pole size and type, bracing, and attachment height. SUPERSEDES FEB 2007 ISSUE APPROVED Signatures on File The following is a suggested configuration for meter bases for overhead and underground meters in residential and commercial applications. OG&E Energy Corp., its subsidiaries and affiliates disclaim any liability for the construction or maintenance practices relating to such suggested configuration. OG&E Electric Services FURNISHED BY ITEM NO. DESCRIPTION 1 METER BASE O.G.& E. CONSUMER INSTALLED BY O.G.& E. X 2 METER 3 SERVICE EQUIPMENT 4 *SERVICE DROP X 5 SERVICE DROP BRACKET X CONSUMER X X X X X X X 6 SERVICE RACEWAY X X 7 SERVICE ENTRANCE CONDUCTOR X X 8 CONSTRUCTION POLE X X 9 GROUNDING ELECTRODE CONDUCTOR X X 10 GROUNDING ELECTRODE X X 11 POLE BRACES X X TEMPORARY SERVICE 3 WIRE SINGLE-PHASE 240/120-VOLTS ® © 3 2 2 8 if roof is not readily accessible) 8 5 4 1 D.Steel conduit (2-in for 200 ampere or 1-1/2-in for 100 ampere) required for service entrance extending through roof. E. Service head not to extend more than 42-in above roof without special approval from OGE. F. 12-ft over areas restricted to pedestrians or other traffic less than 8-ft in height. 16-ft over areas subject to any traffic greater than 8ft. in height. For swimming pools see D262.4 or D262.6. For other situations see D262, D262.1, D262.3 or D262.5. For possible reduced clearance requirements for RESIDENTIAL SINGLE STORY buildings see NESC Table 232-1 footnotes 7 and 8. 24 7 1 Schedule 40 PVC or Better 4 Furnished Installed by Item no. Description 1 Service raceway X X 2 Service entrance conductor X X X X Service head 3 4 OG&E Meter base 100A (281057), 200A (281065) 5 Service equipment 6 Service Drop OG&E Consumer X X X X 7 Service drop bracket X 8 Meter X ® Consumer X X X X OVERHEAD METER INSTALLATION SINGLE PHASE Point of attachment 12-ft or greater as required to ensure service drop cables and drip loop comply with note F. (open wire services may require greater clearances) 1 6 48 to 66-inches 60-inches preferred B. If more than 6-ft of service drop overhangs the roof then a 36-in min distance between the service drop and the roof must be maintained for the service drop outside a 6-ft radius from the service raceway. (applies only 8 Point of attachment 12-ft or greater as required to ensure service drop cables and drip loop comply with note F. (open wire services may require greater clearances) 18-in (min) to service conductor including messenger attachment point and drip loop see notes A & B 7 not readily accessible) C.Service entrance location to be approved by OGE before setting breaker box. f 6 See note E Notes: A. Service raceway must be within 4-ft horizontally of roof edge, otherwise this dimension must be 36-in min. (applies only if roof is Roo 3 24 The following is a suggested configuration for meter bases for overhead and underground meters in residential and commercial applications. OG&E Energy Corp., its subsidiaries and affiliates disclaim any liability for the construction or maintenance practices relating to such suggested configuration. OG&E Electric Services 200-AMPERE MAXIMUM SUPERSEDES NOV 2006 ISSUE APPROVED Signatures on File D731.1 DISTRIBUTION STANDARD FEB 2007 © D731.2 DISTRIBUTION STANDARD JUN 2005 Service entrance raceway furnished and installed by consumer. Leave 24-inches (min) of wire for connection to service. (Furnished and installed by consumer.) Source side of meter base. Service entrance conductors (furnished, installed and connected by consumer) Meter Base 100A 281047 (Furnished by OG&E, installed by Consumer.) Refer to D731.3 for Meter Base 200A 281065 Load side of meter base. (Furnished, installed And connected by consumer.) Signatures on File APPROVED SUPERSEDES DEC 2001 ISSUE The following is a suggested configuration for meter bases for overhead and underground meters in residential and commercial applications. OG&E Energy Corp., its subsidiaries and affiliates disclaim any liability for the construction or maintenance practices relating to such suggested configuration. OG&E Electric Services CONNECTION DIAGRAM SINGLE PHASE 200 AMPERE MAXIMUM ® Leave 24-inches (min) of wire for connection to service. (Furnished and installed by consumer.) Service entrance raceway furnished and installed by consumer. Service lateral conductors (furnished, installed and connected by consumer.) Meter Base, 281065, (underground application), furnished by OG&E, installed by consumer Service entrance conductors (furnished, installed and connected by consumer) CONNECTION DIAGRAM ® SINGLE PHASE 200 AMPERE MINIMUM and commercial applications. OG&E Energy Corp., its subsidiaries and affiliates disclaim any liability for the construction or maintenance practices relating to such suggested configuration. OG&E Electric Services ISSUE SUPERSEDES JUN 2005 ISSUE Signatures on File APPROVED The following is a suggested configuration for meter bases for overhead and underground meters in residential D731.3 © DISTRIBUTION STANDARD AUG 2005 OG&E Electric Services © D732 DISTRIBUTION STANDARD FEB 2007 3 Point of Attachment 12-ft or greater above ground or platform as required to ensure service drop cables and drip loop comply with note A. (open wire services may require greater clearances) APPROVED Signatures on File SUPERSEDES NOV 2006 ISSUE 24 2 18-in (min) to service conductor including messenger attachment point and drip loop 8-inches 2 1 2-inches (min) Steel Conduit 24-inches 5 48 to 66-inches 60-inches preferred 8 1-½-inch (min) Metal or nonmetallic (schedule 40 PVC or better) conduit 7 5 Approved steel conduit (1-½-in min) 8 6 Meter Base 200A 281086 400A 1010183 600A 1007617 7 5 Note: Where metering equipment is exposed to vehicular traffic a protective pipe should be installed 4-ft in front of meter equipment. 9 Point of attachment 12-ft or greater as required to ensure service drop cables and drip loop comply with note A. (open wire services may require greater clearances) 3 8 1 See D731.1 Notes A and B for application of this clearance 4 12-ft or greater as required to ensure service drop cables and drip loop comply with note A. (open wire services may require greater clearances) The following is a suggested configuration for meter bases for overhead and underground meters in residential and commercial applications. OG&E Energy Corp., its subsidiaries and affiliates disclaim any liability for the construction or maintenance practices relating to such suggested configuration. 4 10 NOTE: A. 12-ft over areas restricted to pedestrians or other traffic less than 8-ft in height. 16-ft over areas subject to any traffic greater than 8ft. in height. For swimming pools see D262.4 or D262.6. For other situations see D262, D262.1, D262.4 or D262.5. For possible reduced clearance requirements for RESIDENTIAL SINGLE STORY buildings see NESC Table 232-1 footnotes 7 and 8. FURNISHED BY INSTALLED BY ITEM NO. DESCRIPTION 1 SERVICE DROP X 2 SERVICE DROP BRACKET X 3 SERVICE ENTRANCE CONDUCTOR X X 4 SERVICE HEAD X X 5 SERVICE RACEWAY X X 6 SERVICE EQUIPMENT X X 7 METER BASE X 8 SELF-CONTAINED METER X 9 GROUNDING ELECTRODE CONDUCTOR X X 10 GROUNDING ELECTRODE X X O.G.& E. CONSUMER O.G.& E. CONSUMER X X X X METER INSTALLATION FOR SELF-CONTAINED POLY-PHASE METER 208Y/120 OR 240-delta/120-VOLTS 200,400,600-AMPERE ® OG&E Electric Services © Point of attachment 12-ft or greater above ground or platform as required to ensure service drop cables and drip loop comply with note A. (open wire services may require greater clearances) 4 3 8-inches 2 4 3 24 1 8 5 1-½-inch (min) Metal or nonmetallic (schedule 40 PVC or better) conduit 5 8 7 6 Meter Base 200A 281086 8 10 60-inches preferred 48 to 66-inches (min) 5 7 5 Point of attachment 12-ft or greater as required to ensure service drop cables and drip loop comply with note A. (open wire services may require greater clearances) 24-inches 72-inches (max) 12-ft or greater as required to ensure service drop cables and drip loop comply with note A. (open wire services may require greater clearances) See D731.1 Notes A and B for application of this clearance 6 Source 18-in (min) to service conductor including messenger attachment point and drip loop 2 1 APPROVED Signatures on File SUPERSEDES NOV 2006 ISSUE The following is a suggested configuration for meter bases for overhead and underground meters in residential and commercial applications. OG&E Energy Corp., its subsidiaries and affiliates disclaim any liability for the construction or maintenance practices relating to such suggested configuration. D732.2 DISTRIBUTION STANDARD FEB 2007 9 Load Break Disconnect (No Fuses) kWH Meter Service Equipment Load One-line diagram Note: 1. Disconnect cabinet to be locked by OG&E. 11 NOTE: A. 12-ft over areas restricted to pedestrians or other traffic less than 8-ft in height. 16-ft over areas subject to any traffic greater than 8ft. in height. For swimming pools see D262.4 or D262.6. For other situations see D262, D262.1, D262.4 or D262.5. ITEM NO. DESCRIPTION FURNISHED BY O.G.E. 1 Service drop X 2 Service drop bracket X 3 Service entrance conductor Consumer INSTALLED BY O.G.E. Consumer X X X X 4 Service head X X 5 Service raceway X X 6 Disconnect Switch X X 7 Meter base X 8 Self-contained meter X 9 Grounding electrode conductor X X 10 Service Equipment X X 11 Ground Electrode X X X X METER INSTALLATION FOR SELF-CONTAINED THREE-PHASE METER 480 OR 480Y/277-VOLTS 200 AMPERE MAXIMUM ® © Point of Attachment 12-ft above ground or platform as required to ensure service drop cables and drip loop comply with note A. (open wire services may require greater clearances) 24 To Consumer’s Service Equipment 8 Neutral 7 9 Service Drop 1 Point of Delivery See D731.1 Notes A and B for application of this clearance 2 5 2 Use Spiral Wrap 3 4 48 to 66-inches 60-inches preferred Approved Steel Conduit (1-½-inch min) Point of attachment 12-ft or greater as required to ensure service drop cables and drip loop comply with note A. (open wire services may require greater clearances) 6 Metering Raceway 1-in (min) Metal or Non-Metallic Conduit Schedule 40 PVC or Better Meter Base (max) 25-ft from Ct’s Notes: 1. Where metering equipment is exposed to vehicular traffic, a protective pipe should be installed in concrete 4-ft in front of meter equipment. 8 NOTE: A. 12-ft over areas restricted to pedestrians or other traffic less than 8-ft in height. 16-ft over areas subject to any traffic greater than 8ft. in height. For swimming pools see D262.4 or D262.6. For other situations see D262, D262.1, D262.4 or D262.5. ITEM NO. DESCRIPTION 3 O.G.& E. SERVICE HEAD 1 2 FURNISHED BY CURRENT TRANSFORMERS AND MOUNTING BRACKET METERING RACEWAY AND WEATHERHEAD O.G.& E. X X X X 5 METER WIRING X 6 SERVICE ENTRANCE CONDUCTOR 7 SERVICE DROP BRACKET X 8 METER X 9 2 CLAMPS X CONSUMER X X METER BASE 4 CONSUMER INSTALLED BY X X X X X X X X SERVICE ENTRANCE AND OUTDOOR METERING INSTALLATION ABOVE 200-AMPERES 4 WIRE, POLY-PHASE, 240-delta/120, 208Y/120 OR 480/277-VOLTS ® SUPERSEDES NOV 2006 ISSUE APPROVED Signatures on File 18-in (min) to service conductor including messenger attachment point, CT bracket, and drip loop OG&E Electric Services The following is a suggested configuration for meter bases for overhead and underground meters in residential and commercial applications. OG&E Energy Corp., its subsidiaries and affiliates disclaim any liability for the construction or maintenance practices relating to such suggested configuration. D732.3 DISTRIBUTION STANDARD FEB 2007 OG&E Electric Services © D732.4 DISTRIBUTION STANDARD FEB 2009 Signatures on File APPROVED SUPERSEDES FEB 2007 ISSUE 7 Source 1 24 5 Schedule 40 PVC or better Load Break Disconnect (No Fuses) 6 12 See note 2 Meter Service Equipment Load 3 10 See note 1 2 30-in 5-ft minimum 9 48 to 66-inches 4 See note 1 kWH Meter base 100A 281047 200A 281065 60-inches preferred See note A for minimum to drip loop and service drop cables. (open wire services may require greater clearances) The following is a suggested configuration for meter bases for overhead and underground meters in residential and commercial applications. OG&E Energy Corp., its subsidiaries and affiliates disclaim any liability for the construction or maintenance practices relating to such suggested configuration. 8 11 One-line diagram Notes: 1 Total length of pole is to be a minimum of 18 feet and diameter of pole at ground line is to be a minimum of 7-inches. 2. Disconnect cabinet to be locked by OG&E. NOTE: A. 12-ft over areas restricted to pedestrians or other traffic less than 8-ft in height. 16-ft over areas subject to any traffic greater than 8ft. in height. For swimming pools see D262.4 or D262.6. For other situations see D262, D262.1, D262.4 or D262.5. Item no. Furnished by DESCRIPTION O.G.E. Installed by Consumer O.G.E. Consumer 1 Service head X X 2 Service pole See note A X X 3 Service equipment X X 4 Meter base 5 Service entrance conductor X X 6 Service raceway X X 7 Service drop bracket X 8 Service drop X X 9 Meter X X 10 Grounding electrode Conductor X X 11 Grounding electrode X X 12 Disconnect Switch X X X X X Pressure treated southern yellow pine 480V CONSUMER SERVICE POLE ® © D733 DISTRIBUTION STANDARD FEB 2009 OG&E Electric Services 4 7 10 Signatures on File APPROVED SUPERSEDES FEB 2007 ISSUE 9 Source Load Point of Attachment 12-ft above ground or platform as required to ensure service drop cables and drip loop comply with note C. (open wire services may require greater clearances) 24 5 3 Schedule 40 PVC or Better 8 2 See note A 1 Meter Base 100A 281047 200A 281065 11 Consumer to furnish and install conduit and cable if underground service is desired See note B 30-inches 48 to 66-inches 60-inches preferred See note C for minimum to drip loop and service drop cables. (open wire services may require greater clearances) 24 5-ft (min) The following is a suggested configuration for meter bases for overhead and underground meters in residential and commercial applications. OG&E Energy Corp., its subsidiaries and affiliates disclaim any liability for the construction or maintenance practices relating to such suggested configuration. 6 12 Note: A. Source and load conductors in separate conduits for overhead service B. Diameter of pole at ground line is to be a minimum of 7-inches. C. 12-ft over areas restricted to pedestrians or other traffic less than 8-ft in height. 16-ft over areas subject to any traffic greater than 8ft. in height. For swimming pools see D262.4 or D262.6. For other situations see D262, D262.1, D262.4 or D262.5. ITEM NO. FURNISHED BY DESCRIPTION O.G.E. 1 Meter base X 2 Meter X CONSUMER INSTALLED BY O.G.E. CONSUMER X X ‡3 Service pole X X 4 Service head X X 5 Service entrance conductor X X 6 Service drop X 7 Service drop bracket X 8 Service raceway X X 9 Service wires X X X X 10 Service wiring bracket X X 11 Grounding electrode Conductor X X 12 Grounding electrode X X ‡ Pressure treated southern yellow pine CONSUMER SERVICE POLE 200-AMPERE MAXIMUM PER METER ® OG&E Electric Services © UG Services © APPROVED SUPERSEDES JAN 1978 ISSUE The following is a suggested configuration for meter bases for overhead and underground meters in residential and commercial applications. OG&E Energy Corp., its subsidiaries and affiliates disclaim any liability for the construction or maintenance practices relating to such suggested configuration. Signatures on File U701 UNDERGROUND STANDARD JAN 1997 OG&E Electric Services The following sizes of services are recommended for all normal applications. It is not intended to preclude the use of larger sizes where justified by special conditions of load, voltage drop or voltage flicker. These service sizes are based on the ampacities of the various conductors direct buried and/or in conduit (PVC direct buried). Consider cable direct buried if no part of the cable run is in conduit longer than 20 feet. For conduit sizes refer to U27. Size residential services for 80% of the electrical breaker panel as per NEC. Example: 200-AMP panel x 80% = 160 AMPS. Therefore, a 0AL (stock number 185150) should be used for the service. CUSTOMER'S ESTIMATED DEMAND CABLE DIRECT BURIED CUSTOMER'S ESTIMATED DEMAND CABLE IN PVC, DIRECT BURIED CONDUCTOR SIZE SINGLE PHASE LF = 75% AMPS THREE PHASE LF = 100% AMPS SINGLE PHASE LF = 75% AMPS THREE PHASE LF = 100% AMPS 260 220 162 155 382 321 245 232 448 374 305 286 546 456 370 346 702 572 538 482 2-350AL 2-0000AL 838 680 650 580 2-500AL 2-0000AL PHASE 0AL 185150 0000AL 185151 350AL 185152 500AL 185157 NEUTRAL 2AL 00AL 0000AL 0000AL *Aluminum conductors shall be insulated NOTE: These ampacities were calculated using CYME (CYMCAP PROG) and verified where possible against IEEE STD>835-1994 CRITERIA: Load factor - 75% and 100% Earth RHO - 90º (C-CM)/W Earth ambient temp - 25ºC Conductor temp - 90ºC UNDERGROUND SERVICE RECOMMENDED SIZES ® © APPROVED FIRST ISSUE Customers bus to switchgear See note 2 A B See note 3 N C Vault wall 8 See note 4 12 12 12 1/4 1/4 1/4 1-3/4 1 1¾ 1 1¼ 1¾ 1¾ 1¼ 5¼ 4 5 8 6 8 1-1/8 1-3/4 1-1/8 The following is a suggested configuration for meter bases for overhead and underground meters in residential and commercial applications. OG&E Energy Corp., its subsidiaries and affiliates disclaim any liability for the construction or maintenance practices relating to such suggested configuration. Signatures on File U702 UNDERGROUND STANDARD FEB 1965 OG&E Electric Services Four 9/16 inch holes Six 9/16-inches holes Drilling for 4 x 1/4-inch bar Drilling for 6 x 1/4-inch bar NOTES 1. Electrical contractor shall specify number of bars and size. 2. Phase sequence shall be ABC with A phase on the North or East. 3. The neutral bar may be located at either side of phase bars. 4. The bottom of the bars shall be located a minimum of 6'6 above the vault floor. CUSTOMERS BUS ENTRANCE FOR TRANSFORMER VAULTS ® OG&E Electric Services Riser or pedestal Utility easement 60’ Preferred service route (See note A) Property line 200’ 110’ Lot width+lot depth-building setback+5 Example (60’+110’-25’+5’=150) 300’ Point of service (see note B) Building Setback Line 25’ Residence Example 1/2 acre lot or larger SUPERSEDES APR 1976 ISSUE APPROVED U704 UNDERGROUND STANDARD FEB 2007 Property line The following is a suggested configuration for meter bases for overhead and underground meters in residential and commercial applications. OG&E Energy Corp., its subsidiaries and affiliates disclaim any liability for the construction or maintenance practices relating to such suggested configuration. Signatures on File © Example Typical city size lot NOTES: A. Service route to each consumer should be in the easement and on the consumer's property who will receive service. Service route should not cross other private property unless permanent obstructions prevent installation along preferred route. B. OG&E will supply service to a point on the side of the residence nearest the electricity supply system. If, for good reason, the contractor or builder needs to place the service entrance elsewhere the OG&E company should be notified and the alternate location approved before the service entrance is installed. UNDERGROUND SERVICES PREFERRED ROUTING AND POINT OF SERVICE ® OG&E Electric Services © Underground APPROVED Signatures on File SUPERSEDES JAN 2005 ISSUE © U762 UNDERGROUND STANDARD SEP 2006 Two position meter base 384604 4 7 7 3 Secondary connection box, 428962, refer to U762.1 for connections 4 48 to 66-in 60-in preferred 6-in (min) 5 6 30-in (min) 48 to 66-in 60-in preferred The following is a suggested configuration for meter bases for overhead and underground meters in residential and commercial applications. OG&E Energy Corp., its subsidiaries and affiliates disclaim any liability for the construction or maintenance practices relating to such suggested configuration. OG&E Electric Services Two position meter base 384604 1 1 2 2 NOTE: A. Connection box size 30 X 36 X 14. B. Use Schedule 40 PVC or better. C. Refer to U16, notes 5, 6 and 8. D. Connection Box to be bonded to neutral block with #6-AWG copper wire. FURNISHED BY INSTALLED BY ITEM number DESCRIPTION 1 Service Lateral Raceway 2 Service Lateral X 3 Secondary Connection Box X X 4 Meter Base X X 5 Service Raceway X X 6 Service Entrance Conductor X X 7 Meter O.G. & E. CONSUMER O.G. & E. CONSUMER X X X X X MULTIPLE METER INSTALLATION 200 - AMPERE PER POSITION SINGLE PHASE SELF CONTAINED ® Meter Base (furnished by OG&E, installed and connected by consumer.) Service raceway (furnished, installed and connected by consumer.) Secondary Connection box (30 X 36 X 14) 428962 (furnished by OG&E, installed by consumer.) Raintight fitting Service entrance conductors (furnished and installed by consumer, connected 350-kcmil (maximum) See note 6 Connector Blocks 264359 with covers. See note 5. (Furnished, installed and connected by OG&E.) Place instructions as to where service is coming from. Service lateral conductors (furnished and installed by OG&E.) Service lateral raceway (furnished and installed by consumer.) See note 2 NOTES: 1. Consumer to install service entrance conductors and make connections at meter enclosure. 2. Plastic bushing required for steel conduit to protect cable. 3. Connection box and blocks to be furnished by OG&E. 4. Refer to U16 notes 5, 6 and 8. 5. Connection Box to be bonded to neutral block with #6-AWG copper wire 6. Place identifying tag on service conductors with information relating to where service is coming from (pedestal, transformer, pipe or no pipe under driveway.) Refer to U16. CONNECTION DIAGRAM ® FOR MULTIPLE METER INSTALLATION SINGLE PHASE SELF CONTAINED METERS The following is a suggested configuration for meter bases for overhead and underground meters in residential and commercial applications. OG&E Energy Corp., its subsidiaries and affiliates disclaim any liability for the construction or maintenance practices relating to such suggested configuration. OG&E Electric Services SUPERSEDES SEP 2006 ISSUE Signatures on File APPROVED U762.1 © UNDERGROUND STANDARD SEP 2007 Service lateral conductors (furnished, installed and connected by OG&E) Meter Base, 281065, (underground application), furnished by OG&E, installed by consumer See note 1 Place instructions as to where service is coming from. Service entrance conductors (furnished, installed and connected by consumer) Plastic bushing required for steel conduit to protect cable 3-in Serv ice lateral raceway furnished and installed by consumer Service laterals furnished and installed by OG&E Notes: 1. Place identifying tag on service conductors with information relating to where service is coming from (pedestal, transformer, pipe or no pipe under driveway.) Refer to U16. ® CONNECTION SINGLE PHASE DIAGRAM 200-AMPERES MAXIMUM The following is a suggested configuration for meter bases for overhead and underground meters in residential and commercial applications. OG&E Energy Corp., its subsidiaries and affiliates disclaim any liability for the construction or maintenance practices relating to such suggested configuration. OG&E Electric Services SUPERSEDES JUN 2005 ISSUE APPROVED Signatures on File U762.3 © UNDERGROUND STANDARD MAR 2006 © UNDERGROUND STANDARD SEP 2007 Service lateral conductors (furnished, installed and connected by OG&E) APPROVED Signatures on File SUPERSEDES MAR 2006 ISSUE The following is a suggested configuration for meter bases for overhead and underground meters in residential and commercial applications. OG&E Energy Corp., its subsidiaries and affiliates disclaim any liability for the construction or maintenance practices relating to such suggested configuration. OG&E Electric Services U762.4 Service entrance conductors (furnished and installed by consumer, connected by consumer) See note 2 Place instructions as to where service is coming from. Meter Base 281109 Furnished by OG&E Installed by Consumer 3-in Schedule 40 PVC or better Furnished and Installed by Consumer Plastic bushing required for steel conduit to protect cable Notes: 1. When installing for 120/208-Volts the 5th terminal, 1030978, is required. 2. Place identifying tag on service conductors with information relating to where service is coming from (pedestal, transformer, pipe or no pipe under driveway.) Refer to U16. CONNECTION DIAGRAM SINGLE PHASE 320-AMPERES MAXIMUM ® OG&E Electric Services The following is a suggested configuration for meter bases for overhead and underground meters in residentialand commercial applications. OG&E Energy Corp., its subsidiaries and affiliates disclaim any liability for theconstruction or maintenance practices relating to such suggested configuration. U762.9 © UNDERGROUND STANDARD FEB 2012 Meter Base 1010183 Furnished by OG&E Installed by Consumer Service lateral conductors (furnished, installed and connected by OG&E) Service entrance conductors (furnished and installed by consumer, connected by OG&E) See note 2 Plastic bushing required for steel conduit to protect cable 3-in Schedule 40 PVC or better Furnished and Installed by Consumer Notes: 1. For 277/480 refer to U765 and U765.1 for installation 2. Place identifying tag on service conductors with information relating to where service is coming from (pedestal, transformer, pipe or no pipe under driveway.) Refer to U16. CONNECTION DIAGRAM THREE PHASE 320 AMPERE MAXIMUM SERVICE VOLTAGE 120/240 AND 120/208-Volts SUPERSEDES SEP 2007 ISSUE APPROVED Signatures on File Place instructions as to where service is coming from. © APPROVED SUPERSEDES AUG 1998 ISSUE Meter Base 281074 7 4 5 4 60-in preferred 66-in (max) 30-in 2 1 Schedule 40 PVC 2 or better 3 * 4 INSTALLED BY DESCRIPTION O.G.&E. ‡ 2 3 FURNISHED BY ITEM Number 1 6 (min) 6-in Refer to U765.1 Table 1 for cabinet size and other details 7 (min) 48-in 3 (min) The following is a suggested configuration for meter bases for overhead and underground meters in residential and commercial applications. OG&E Energy Corp., its subsidiaries and affiliates disclaim any liability for the construction or maintenance practices relating to such suggested configuration. Signatures on File U765 UNDERGROUND STANDARD FEB 2010 OG&E Electric Services Service Lateral CONSUMER X Service Lateral Raceway Current Transformer Enclosure Transformer rated Meter Base O.G.&E. CONSUMER X X X X X X X 5 Service Equipment X X 6 Metering Conduit 1-inch X X 7 Meter X X * Alternate location is shown dotted ‡ Size and number of conduits as specified by OG&E NOTES: (1) Where metering equipment is exposed to vehicular traffic a protective pipe should be installed in concrete 4-ft in front of metering equipment. (2) Wiring from CTs to meter is not to exceed 20 feet in total length. METER INSTALLATION FOR CURRENT TRANSFORMER METERING SINGLE OR THREE PHASE 1200-AMPERES MAXIMUM ® © Secondary Connection Blocks furnished by OG&E (See Table 2) CT Meter CT polarity to face OG&E entrance A B C Optional Self-contained, 200 amp, three phase meter A B N C “A” phase + Customer service cables “B” phase + “C” phase See note 4 + + + + Alternate mounting direction for Ct’s. Place instructions as to where service is coming from. Customer cables to terminate in secondary connection blocks (parallel cable if necessary) See note 5 Place instructions as to where service is coming from. Neutral by OG&E OG&E entrance and customer exit should always be on opposite sides to provide proper wire spacing NOTES: 1. Current transformers to be installed in the position that provides the best spacing for line and load conductors. 2. Service and metering connections made by OG&E. 3. Verify that customer has established a driven ground at their main switch panels. 4. Position supply cable to center of connector block. 5. Place identifying tag on service conductors with information relating to where service is coming from (pedestal, transformer, pipe or no pipe under driveway.) Refer to U16. 6. Wiring from CTs to CT meter is not to exceed 20 feet in total length. CONNECTOR BLOCKS TABLE 1 428962 30 x 36 x 14 ‡ 1009107 42 x 48 x 14 ‡ Stock Account 1009107 is for 1200 amp applications ONLY! TABLE 2 264358 2 6-AWG thru 350-KCMIL 2 6-AWG thru 350-KCMIL 600 264195 2 6-AWG thru 500-KCMIL 4 6-AWG thru 500-KCMIL 800 1019876 2 0-AWG thru 750-KCMIL 4 0-AWG thru 750-KCMIL 1200 CONNECTION DIAGRAM ® THREE PHASE CT METER INSTALLATION WITH OPTIONAL SELF-CONTAINED METER The following is a suggested configuration for meter bases for overhead and underground meters in residential and commercial applications. OG&E Energy Corp., its subsidiaries and affiliates disclaim any liability for the construction or maintenance practices relating to such suggested configuration. CT cabinet shown with two 4-in conduits and parallel cables (See Table 1 for cabinet sizes) OG&E Electric Services SUPERSEDES JUL 2009 ISSUE APPROVED Signatures on File U765.1 UNDERGROUND STANDARD FEB 2010 © APPROVED SUPERSEDES MAY 1992 ISSUE NOTES: A. Consumer shall leave 6-ft of cable beyond point Z B. Use Schedule 40 PVC or better 7 6 C. Refer to U748 and U748.1 for details on terminations in pedestal D. Conduit should extend a minimum of 18-inches below grade 4 30 to 66-in 60-in preferred 9 3 5 12 C 3-ft (min) A B 24-in (min) 2 D 3-ft (min) The following is a suggested configuration for meter bases for overhead and underground meters in residential and commercial applications. OG&E Energy Corp., its subsidiaries and affiliates disclaim any liability for the construction or maintenance practices relating to such suggested configuration. Signatures on File U771 UNDERGROUND STANDARD AUG 1998 OG&E Electric Services Z 1 8 ITEM NUMBER FURNISHED BY DESCRIPTION O.G.&E. CONSUMER INSTALLED BY O.G.&E. CONSUMER 1 Temporary Service Lateral X X 2 Service Lateral Raceway X X 3 Meter Base X 4 Meter X X 5 Service Pedestal X X 6 Service Equipment X X 7 Treated Support X X 8 Grounding Electrode X X 9 Grounding Electrode Conductor X X X TEMPORARY SERVICE 3-WIRE, SINGLE-PHASE 240/120-VOLTS ® © The following is a suggested configuration for meter bases for overhead and underground meters in residentialand commercial applications. OG&E Energy Corp., its subsidiaries and affiliates disclaim any liability for theconstruction or maintenance practices relating to such suggested configuration. U772 UNDERGROUND STANDARD DEC 2011 OG&E Electric Services Meter Base 200A 1Ø 281065 3Ø 281086 3 5 4 2 Schedule 40 PVC or better (3-inch conduit for 200-Ampere Meter Base) 7 48 to 66-in 60-in preferred 6 30-in (min) See note 1 1 FURNISHED BY Signatures on File APPROVED SUPERSEDES JUL 2010 ISSUE ITEM NUMBER DESCRIPTION O.G.& E. INSTALLED BY CONSUMER O.G.& E. X CONSUMER 1 Service Lateral X 2 Service Lateral Raceway 3 Meter Base 4 Service Raceway X X 5 Service Equipment X X 6 Meter 7 Service lateral raceway clamp, (1) minumum X X X X X X X X NOTE: 1. When foundation obstructions exist, the use of schedule 40 (minimum) conduit with (2) 45-degree elbows to clear obstructions is permissible. The top 45-degree elbow is to be at or below ground level. METER INSTALLATION FOR SELF-CONTAINED SINGLE PHASE OR THREE PHASE METER 208Y/120 OR 240D /120 OR 240/120 VOLTS 200-AMPERES MAXIMUM © UNDERGROUND STANDARD SEP 2007 The following is a suggested configuration for meter bases for overhead and underground meters in residentialand commercial applications. OG&E Energy Corp., its subsidiaries and affiliates disclaim any liability for theconstruction or maintenance practices relating to such suggested configuration. OG&E Electric Services U772.2 Conductor having highest voltage to ground in 4-wire delta system must be connected to the right hand terminal and marked with orange tape at the pedestal and in the meter base. See note 1 Place instructions as to where service is coming from. Meter Base 281086 SUPERSEDES JUN 2005 ISSUE APPROVED Signatures on File Plastic bushing required for steel conduit to protect cable. Schedule 40 PVC or better Furnished and Installed by Consumer. Service laterals furnished and installed by OG&E. NOTES: 1. Place identifying tag on service conductors with information relating to where service is coming from (pedestal, transformer, pipe or no pipe under driveway.) Refer to U16 CONNECTION DIAGRAM FOR SELF-CONTAINED THREE PHASE FOUR WIRE METER 208Y/120 OR 240Δ/120 VOLT 200-AMPERE MAXIMUM © The following is a suggested configuration for meter bases for overhead and underground meters in residentialand commercial applications. OG&E Energy Corp., its subsidiaries and affiliates disclaim any liability for theconstruction or maintenance practices relating to such suggested configuration. U773.2 UNDERGROUND STANDARD JAN 2011 OG&E Electric Services Meter shall be installed on load side of load Break disconnect LOAD 4 6 Meter Base 2 KWH METER Load break Disconnect (no fuses) Schedule 40 PVC or 1 better (3-in conduit for 200-ampere meter base) 30-in (min) 66-in (m ax) 60-in preferred 3 ONE-LINE DIAGRAM (min) 30-in SOURCE 5 FURNISHED BY SUPERSEDES AUG 1998 ISSUE APPROVED Signatures on File ITEM NO. DESCRIPTION O.G. & E. CONSUMER INSTALLED BY O.G. & E. 1 Service Lateral Raceway 2 Load-Break Disconnect 3 Meter Base X 4 Self-Contained Meter X X 5 Service Lateral X X 6 Service Raceway See Note 1 CONSUMER X X X X X X NOTE: 1. OG&E to furnish Load-Break Disconnect for 480-volt service in Arkansas METER INSTALLATION FOR SELF-CONTAINED METER 480 OR 480Y/277-VOLTS 200-AMPERES MAXIMUM X 4 Refer to U762.1 for connection box and neutral block bonding connection 30-in (min) 6-in (min) 3 2 1 FURNISHED BY Item Number 1 DESCRIPTION Service Lateral O.G.&E. O.G.&E. X ‡ 2 Service Lateral Raceway ** 3 Secondary Connection Box X Meter Base X 4 CONSUMER INSTALLED BY CONSUMER X X X X X *5 Service Equipment X X *6 Service Entrance Conductor X X 7 Meter X X ‡ Size and Number of conduits as specified by OG&E * Not Shown ** Secondary Connection Box shall be bonded to neutral block GROUP METER INSTALLATION ® The following is a suggested configuration for meter bases for overhead and underground meters in residential and commercial applications. OG&E Energy Corp., its subsidiaries and affiliates disclaim any liability for the construction or maintenance practices relating to such suggested configuration. 7 © 200-AMPERE PER POSITION 120/240D-120/208Y SELF CONTAINED-THREE PHASE SUPERSEDES FEB 1993 ISSUE APPROVED Signatures on File Meter Base 281086 OG&E Electric Services 48-in to 66-in 60-in preferred U773.3 UNDERGROUND STANDARD AUG 1998 © U773.4 UNDERGROUND STANDARD AUG 1998 OG&E Electric Services Signatures on File APPROVED SUPERSEDES JAN 1993 ISSUE 7 4 5 LOAD 48-in to 66-in 60-in preferred KWH Meter Disconnect Refer to U762.1 Load Break for connection box (No Fuses) and neutral block bonding connection 30-in (min) 3 6-in (min) The following is a suggested configuration for meter bases for overhead and underground meters in residential and commercial applications. OG&E Energy Corp., its subsidiaries and affiliates disclaim any liability for the construction or maintenance practices relating to such suggested configuration. Meter Base 281086 2 SOURCE ONE-LINE- DIAGRAM 1 FURNISHED BY Item Number 1 DESCRIPTION Service Lateral O.G.&E. CONSUMER INSTALLED BY O.G.&E. X CONSUMER X ‡ 2 Service Lateral Raceway ** 3 Secondary Connection Box X 4 Meter Base X 5 Service Equipment X X Service Entrance Conductor X X *6 7 Meter X X X X X X ‡ Size and Number of conduits as specified by OG&E * Not Shown ** Secondary Connection Box shall be bonded to neutral block GROUP METER INSTALLATION 200-AMPERE PER POSITION 480D OR 480Y/277-VOLTS SELF CONTAINED-THREE PHASE ® 7 Pipe Cap Face meter 90 degrees to Transformer 3 7 9 5 5 9 9 8 9 4 6 60” Preferred 66” Maximum 6 12345 9 6 9 8 6 30” Min. 9 2 Galvanized pipe is to be concreted into ground at a depth of 2.5ft with 6 inches of concrete surrounding pole. 6” Min. 2 Maximum see note 1 FURNISHED BY ITEM Number 1 INSTALLED BY DESCRIPTION O.G.&E. ‡ 2 6 Service Lateral CONSUMER O.G.&E. X CONSUMER X Service Lateral Raceway X X 3 CT Meter Base X X 4 Transformer X 5 3-inch Galvanized Pipe set in concrete X X 6 Metering Conduit 1-inch sch 40 X X 7 Meter X 8 CT Cabinet X 9 1 5/8-inch Kindorf X X X X X ‡ Size and number of conduits as specified by OG&E Notes Wiring from CTs to meter is not to exceed 20 feet in total length. 1. 2. Place Cap on Support to keep moisture from inside of pipe to prevent deterioration. 3. Pole to be galvanized 3- inch pipe. Pole to be set at a depth of 30-inches with a minimum of 6-inches of concrete surrounding pole. 4. When two customers are to be served from one transformer or the CT Box and meter cannot be on a building, place two poles with using 1-5/8-inch Kindorf between poles to attach equipment. 5. CT boxes on double support option could be fastened to back side of supports when needed. 6. Refer to U562.* For CT Installations. CT METERING COMPONENTS ® The following is a suggested configuration for meter bases for overhead and underground meters in residential and commercial applications. OG&E Energy Corp., its subsidiaries and affiliates disclaim any liability for the construction or maintenance practices relating to such suggested configuration. 3 OG&E Electric Services INSTALLATION INSTRUCTIONS WHEN MORE THAN ONE CUSTOMER IS SERVED FROM TRANSFORMER SUPERSEDES MAY 2005 ISSUE APPROVED Signatures on file U773.5 © UNDERGROUND STANDARD FEB 2010 © U773.6 UNDERGROUND STANDARD FEB 2010 Face meter 90 degrees to transformer Galvanized 3” pipe Mount unistrut across top & bottom of CT meter base, 281074. Use unistrut clamps to secure CT meter base to galvanized 3” pipe. 2 5 60” Preferred 66” Maximum 12345 3 4 30” Min. 24” Min. 1 Galvanized 3” pipe is to be concreted into ground at a minimum depth of 24 inches with 6” of concrete surrounding pipe. 6” Min. Maximum see note 1 FURNISHED BY ITEM Number INSTALLED BY DESCRIPTION O.G.&E. APPROVED Signatures on File SUPERSEDES MAY 2007 ISSUE The following is a suggested configuration for meter bases for overhead and underground meters in residentialand commercial applications. OG&E Energy Corp., its subsidiaries and affiliates disclaim any liability for theconstruction or maintenance practices relating to such suggested configuration. OG&E Electric Services 1 Transformer X 2 CT Meter Base X 3 Galvanized 3” pipe 4 Metering Conduit 1-inch sch 40 or rigid 5 Meter CONSUMER O.G.&E. CONSUMER X X X X X X X X Notes 1. Wiring from CTs to meter is not to exceed 20 feet in total length. 2. For one customer and CT’s in transformer, galvanized 3 inch pipe set in concrete, a minimum of 24 inches deep. CT METERING COMPONENTS INSTALLATION INSTRUCTIONS ONE CUSTOMER AND CT’S IN TRANSFORMER OG&E Electric Services © 4 5 36” Pipe Caps 6 3 8 8 3 6 4 60” Preferred 66” Maximum 3 2 6 ed Fus nnect co Dis witch S 6 7 2 7 5 1 30” Min. Groundline 2 7 6 Load Source 6” Min. Galvanized 3” pipe is to be concreted into ground at a minimum depth of 30 inches with 6” of concrete surrounding pipe. Load 1 2 Source FURNISHED BY O.G.&E. 1 ‡ 2 INSTALLED BY DESCRIPTION CONSUMER O.G.&E. X Service Lateral CONSUMER X X Service Lateral Raceway & 90 Bend 3 3-inch Galvanized Pipe set in concrete 4 Meter X 5 Meter Base X 6 1 5/8-inch Kindorf 7 Conduit and wire X X 8 200 Amp Fused Disconnect Switch X X X X X X X X ‡ Size and number of conduits as specified by OG&E Notes 1. Place Cap on Support to keep moisture from inside of pipe to prevent deterioration. 2. Pole to be galvanized 3-inch pipe. Pole to be set at a depth of 30-inches with a minimum of 6-inches of concrete surrounding pole. 3. When meter cannot be mounted on a building, place two poles 36-inches apart with 1-5/8-inch Kindorf between poles to attach equipment. METER INSTALLATION ® FOR SELF-CONTAINED SINGLE PHASE METER 240/120 VOLTS 200-AMPERES MAXIMUM SUPERSEDES JAN 2011 ISSUE APPROVED Signatures on File ITEM Number 7 The following is a suggested configuration for meter bases for overhead and underground meters in residential and commercial applications. OG&E Energy Corp., its subsidiaries and affiliates disclaim any liability for the construction or maintenance practices relating to such suggested configuration. U773.7 UNDERGROUND STANDARD MAY 2011 © U773.8 UNDERGROUND STANDARD MAR 2012 5 4 8 42” 6 Pipe Caps 3 8 6 60” Preferred 66” Maximum 4 9 6 5 d use ct n-F No conne Dis witch S 3 6 See e not 6 2 7 3 12” 6” 6 9 30” Min. Groundline 7 1 2 2 ed Fus nnect co Dis witch S 6 Load 6” Min. Source Galvanized 3” pipe is to be concreted into ground at a minimum depth of 30 inches with 6” of concrete surrounding pipe. 2 Source 7 Load FURNISHED BY ITEM Number ‡ 2 INSTALLED BY DESCRIPTION O.G.&E. 1 APPROVED Signatures on File SUPERSEDES MAY 2011 ISSUE The following is a suggested configuration for meter bases for overhead and underground meters in residentialand commercial applications. OG&E Energy Corp., its subsidiaries and affiliates disclaim any liability for theconstruction or maintenance practices relating to such suggested configuration. OG&E Electric Services CONSUMER O.G.&E. X Service Lateral CONSUMER X X Service Lateral Raceway & 90 Bend 3 3-inch Galvanized Pipe set in concrete 4 Meter X 5 Meter Base, 281086 X 6 1 5/8-inch Kindorf X X 7 Conduit and wire X X 8 200 Amp Non-Fused Disconnect X X 9 200 Amp Fused Disconnect X X X X X X ‡ Size and number of conduits as specified by OG&E Notes 1. Place Cap on Support to keep moisture from inside of pipe to prevent deterioration. 2. Pole to be galvanized 3-inch pipe. Pole to be set at a depth of 30-inches with a minimum of 6-inches of concrete surrounding pole. 3. When meter cannot be mounted on a building, place two poles 42-inches apart with 1-5/8-inch Kindorf between poles to attach equipment. 4. The use of a disconnect ahead of the meter is required for 480 volt applications. 5. Refer to U773.9 for 480 volt two-wire wiring details. 6. For all 480V applications install sticker, 302228, on meter base. METER INSTALLATION FOR SELF-CONTAINED METERS 240/480Δ, 480Y/277, 480Δ, OR 480-VOLT TWO-WIRE 200-AMPERES MAXIMUM 1 Service entrance conductors (Furnished, installed, and connected by consumer.) Meter Base, 281086 (Furnished by OG&E, installed by consumer.) N A Line 16S Fitzall TM Load Note: Requires CL200 FM16S Meter. Notify Meter Department to program as a FM1S 2-wire 480-volt meter. Identifying tag, see note 1 Service load conductors (Furnished, installed, and connected by consumer to fused disconnect switch.) Place instructions as to where service is coming from. Plastic bushing required for steel conduit to protect cable. Service raceway, schedule 40 PVC or better (Furnished and Installed by Consumer.) Load Break Disconnect OK - Furnished and installed by consumer AR - Furnished by OG&E and installed by consumer Non-Fused Disconnect Switch Service lateral raceway, schedule 40 PVC or better (Furnished and Installed by Consumer.) Service lateral (Furnished and installed by OG&E.) NOTES: 1. Place identifying tag on service conductors with information relating to where service is coming from (pedestal, transformer, pipe or no pipe under driveway.) Refer to U16. CONNECTION DIAGRAM FOR SELF-CONTAINED SINGLE PHASE 480-VOLT TWO-WIRE SERVICE 200-AMPERE MAXIMUM PREVIOUSLY ISSUED AS U772.2 MAY 2011 Signatures on File The following is a suggested configuration for meter bases for overhead and underground meters in residentialand commercial applications. OG&E Energy Corp., its subsidiaries and affiliates disclaim any liability for theconstruction or maintenance practices relating to such suggested configuration. OG&E Electric Services APPROVED U773.9 © UNDERGROUND STANDARD MAR 2012