Franklin Electric Application/Installation Data No. 1/2013 Franklin Electric submersible motors are offered in either DOL or Star-Delta version. Today’s Franklin AID will show the differences between the two and characteristics of the Star-Delta connection. Depending on the geographical location in which the submersible motor is to be installed, the local energy provider gives technical connection guidelines that have to be kept for the operation of electrical drives. One of these guidelines implements reduced start-up current for submersible motors for certain drive capacities which differ from region to region. The Star-Delta drive of subPHUVLEOHPRWRUVLVDFRVWHI¿FLHQWSRVVLELOLW\WRDGKHUHWRWKHVHJXLGHOLQHV Risks and details of the Star – Delta start will be highlighted in our next FE-AID edition. Picture 1: DOL (Direct Online) Motor Picture 2: Star-Delta Motor Europa GmbH D-54516 Wittlich / Germany HPDLO¿HOGVHUYLFH#IUDQNOLQHOHFWULFGH ZZZIUDQNOLQHOHFWULFHX 7HO )D[ Direct-on-line (DOL) starting motors only require adequate motor protection, whereas star-delta starting implies a more complex circuitry composed of several relays and contactors. The following two images demonstrate the different possibilities for electrical connection: Picture 3: DOL Picture 4: Star-Delta Europa GmbH D-54516 Wittlich / Germany HPDLO¿HOGVHUYLFH#IUDQNOLQHOHFWULFGH ZZZIUDQNOLQHOHFWULFHX 7HO )D[ The following images show the electrical circuitry of the three motor windings and their phase voltages: Picture 5: STAR connection of the motor windings Picture 6: DELTA connection of the motor windings Europa GmbH D-54516 Wittlich / Germany HPDLO¿HOGVHUYLFH#IUDQNOLQHOHFWULFGH ZZZIUDQNOLQHOHFWULFHX 7HO )D[ As shown in Pic. 5 and 6, the difference in connections is not just limited to the different circuitries, but also in the resulting voltages of the windings..Whereas in the DOL connection the windings are supplied by the voltage they are designed for permanently, the STAR connection is operated at a YROWDJHUHGXFHGE\WKHIDFWRU¥)ROORZLQJSULQFLSOHVUHVXOWIURPWKLVZKLFKKDYHWREHUHVSHFWHG by all means for a continuous operation of a STAR-DELTA motor: The motor-current (Amps) of a STAR-DELTA motor during start (IԚ) is reduced roughly by factor 0,58; a motor with a nominal starting current of 400A will consume only 232 A in STAR – connection. 7KLVIXOO¿OOVWKHUHTXLUHPHQWRIDFXUUHQWUHGXFHGVWDUW (PԚ), the available mechanical performance on the shaft to drive the pump, is also reduced to 1/3 of the nominal performance. To avoid an overloading of t he motor, it is necessary to observe the power demand of the pump during startup in comparison with the start current of the motor. The available shaft torque (MԚ) also reduces while start to 1/3 of the nominal torque. This also raises the necessity, to compare the demanded starting torque of the pump to the available torque of the motor, and – to do the right selection. For deeper questions/explanations please consult your Field Service Engineer or the technical staff of FEE. Europa GmbH D-54516 Wittlich / Germany HPDLO¿HOGVHUYLFH#IUDQNOLQHOHFWULFGH ZZZIUDQNOLQHOHFWULFHX 7HO )D[ Seminars in FRANKLIN TECH TRAINING CENTER 2013 Please visit our website:http://www.franklin-electric.de and sign up. Upon request we also offer in 2013 seminars tailored to your requirements. Europa GmbH D-54516 Wittlich / Germany HPDLO¿HOGVHUYLFH#IUDQNOLQHOHFWULFGH ZZZIUDQNOLQHOHFWULFHX 7HO )D[