Series CK Three and four pole contactors 150 to 825A (AC3) 200 to 1250A (AC1) Contactors • Control circuit: Alternating current up to 690V Direct current up to 500V • Degree of protection IP00 (IPxxB with accessories) • CK07...CK13: auxiliary and coil terminals originally protected against accidental contacts. Protection for power contacts on request (see accessories) • Terminals protected against accidental contacts according to VDE 0106 T.100, VBG4. • CK_ _E_with electronic module suitable for DC and AC. (50/60Hz) • CK contactors always provided with one auxiliary contact block BCLL11 (1NO+1NC) Intro A B Standards IEC/EN 60947-1 IEC/EN 60947-4-1 IEC/EN 60947-5-1 EN 50005 UL 508 NEMA ICS 1 BS 5424 & 775 Standard voltages CSA 22.2/14 CENELEC HD 419 NFC 63-110 ASE 1025 UNE 20109 VDE 0660/102 To complete the catalogue number, replace the symbol © by the code corresponding to the voltage and frequency of the control circuit. Alternating current (V) Three-pole contactors: Four-pole contactors: © C D F CK75CA3..., CK08CA3..., CK85BA3... CK07BA4..., CK08BA4... G H I 24 42 48 50Hz J K M 110 127 N 230 C Approvals/Marking (1) 60Hz 24 48 110 120 Three-pole contactors: Four-pole contactors: CE © 1 50/60Hz 24 E 220 277 Lloyd’s Register T U V 380 W 2 3 6 400 240 380 480 440 13 Bureau Veritas RINA © J N U CK13BA3... CK13BA4... Y Z J N U 50Hz 110 220 380 230 400 50/60Hz 110 220 380 480 600 240 440 500 660 G Control circuit with rectifier bridge © 60Hz 120 240 480 Direct current (V). With electronic module (0.7 ... 1.3 x Us) H (Contact GE for details) Three-pole contactors: CK75CE3...., CK08CE3..... © WD WE WF WH WJ WN Voltage 24 33 48 72 110 220 I Alternating c. / Direct c. (V). With electronic module (0.8 ... 1.10 x Us) Three-pole & four-pole contactors: CK ....... E...... J/X A.62 Order codes ! Aux. contact blocks ! Accessories & Spares ! Technical data ! Dimensions ! pg. A.63 pg. A.64 pg. A.65 pg. A.102 pg. A.118 © D F J N U Y Voltage 24 42 110 220 380 440 28 48 127 250 415 500 (1) CK13 not UL Y 600 48 110 230 400 Three-pole contactors: Four-pole contactors: X Z 415 440 500 660 690 CK75CA3..., CK08CA3..., CK85BA3... CK07BA4..., CK08BA4... Alternating current (V) F S Alternating current (V). Dual-frequency coil D cULus R 220 240 Series CK Three pole contactors Max.oper.current Noninductive loads AC1 A Admissible power AC3 Motors <440V, 220V 380V 415V 440V 500V 230V 400V 440V 3~ 50/60Hz kW kW kW kW kW AC3 HP HP HP HP HP A Electrical endurance Cat. AC3 Operations Control circuit: Alternating current Cat. no. (1) Control circuit: A.C. / D.C. Pack Ref. no. see bottom Cat. no. (1) Pack Ref. no. see bottom 150 45 60 75 80 80 100 100 108 108 135 1.7x106 CK75CA311 © 1 CK75CE311 © 1 250 185 55 75 90 100 100 110 125 135 135 150 1.2x106 CK08CA311 © 1 CK08CE311 © 1 315 205 65 88 110 125 125 132 150 170 170 180 1.7x106 CK85BA311 © 1 CK85BE311 © 1 315 250 75 132 132 132 160 100 180 180 180 220 1.5x106 - CK09BE311 © 1 450 309 90 160 160 185 200 125 220 220 250 270 1,1x106 - CK95BE311 © 1 600 420 125 220 230 230 300 170 300 312 312 405 1x106 - CK10CE311 © 1 700 550 160 280 315 315 400 220 380 425 425 540 0.8x106 - CK11CE311 © 1 1000 700 220 375 400 425 480 300 510 540 650 0.7x106 - CK12BE311 © 1 1250 825 250 450 450 450 500 340 610 610 610 680 0.7x106 (2) CK13BA311 © 1 - 1 1 1 1 - Order codes 250 Intro A Spare coil CK75CA3 ... CK08CA3 CK85BA3 CK13BA3 Control circuit with incorporated rectifier bridge CK13BA3 Coil Electronic module CK75CE3 ... CK08CE3 CK85BE3 ... CK95BE3 CK12BE3 CK10CE3 ... CK11CE3 CK75CE3 ... CK08CE3 CK85BE3 ... CK95BE3 CK12BE3 CK10CE3 ... CK11CE3 C12168 © C04255 © C08998 © C09120 © - KB4E © KB5E © KB6E © KB7E © KM4E © KM5E © KM6E © KM7E © B 1 1 1 1 1 1 1 1 (1) To complete the catalogue number, replace the symbol © by the code corresponding to the voltage and frequency of the control circuit (see A.62). (2) CK13 non alow the aux. block in right side. C D E F G H I J/X For reference numbers, see chapter X, pg. X.5 A.63 Series CK Mounting positions Conformity to standards IEC/EN 60947-1 NF C 63-110 BS 5424 & 775 IEC/EN 60947-4-1 ASE 1025 NEMA ICS 1 CENELEC HD 419 CSA 22.2/14 VDE 0660/102 UL 508 UNE 20109 EN 50005 Approvals cULus RINA NOM FI Lloyd’s Register Bureau Veritas CE With the same pick-up and drop-out voltage With the same rated power Contactors Ambient conditions Intro A B C Storage temperature Operation temperature -40ºC to +60ºC Altitude up to 3000m from 3000 up to 4000m from 4000 up to 5000m -55ºC to +80ºC Nominal values 90%Ie 80%Ue 80%Ie 75%Ue Climatic resistance (IEC 68-2) Continuous tests 40 / 125 / 56 Cold (72h) Temperature Dry heat (96h) Temperature Relative humidity Humid heat (56 days) Temperature Relative humidity Cyclical test First half-cycle (12h) Low temperature Relative humidity Second half-cycle (12h) Low temperature Relative humidity Number of consecutive cycles -40ºC +125ºC < 50% +40ºC 95% +25ºC 93% +55ºC 95% 6 Terminal capacity and tightening torque CK07B D E F G H I J/X A.102 Solid (mm2) Finely stranded w/end sleeve (mm2) Finely stranded w/o end sleeve (mm2) Stranded (mm2) AWG wires (mm2) Tightening torque (Nm) (Lb x in) Finely stranded w/end sleeve (mm2) AWG wires with end sleeve (mm2) Busbars Tightening torque (Nm) (Lb x in) CK75C CK08C CK08B CK95B CK10C CK11C CK12B CK13B 1 x 120 2 x 95 1 x 300 2 x 107 2 (25 x 5) 8 70 1 x 240 2 x 150 1 x 500 2 x 300 2 (25 x 5) 23 200 2 x 185 2 x 240 – – 2 x 500 2 (35 x 10) 31.5 275 – 2 (35 x 10) 31.5 275 – 2 (60 x 10) 31.5 275 1.5...95 2...35 2...50 1.5...95 16...00 8 70 2 x 350 2 (35 x 10) 31.5 275 Series CK Power circuit CK75C CK08C CK85B CK09B CK95B CK10C CK11C CK12B CK13B 250 150 1000 1000 250 25...400 1850 250 185 1000 1000 250 25...400 2200 315 205 1000 1000 315 25...400 2500 315 250 1000 1000 315 25...400 2500 450 309 1000 1000 450 25...400 3700 600 420 1000 1000 600 25...400 6500 700 550 1000 1000 700 25...400 6500 1000 700 1000 1000 1000 25...400 8400 1250 825 1000 1000 1250 25...400 8250 1600 1600 1000 350 2500 2500 2300 1250 900 600 10 1850 1850 1200 350 2500 2500 2300 1250 900 600 10 2000 2000 1660 850 4000 3200 2400 1400 1000 750 10 3500 3500 2200 1100 5500 3500 2500 1600 1200 900 10 3500 3500 2200 1100 5500 3500 2500 1600 1200 900 10 5600 5600 5000 3000 7500 5200 4000 2800 1800 1200 10 5600 5600 5000 3000 7500 5200 4000 2800 1800 1200 10 7300 7000 6700 3500 9700 7700 6100 4400 3500 2300 10 6600 6600 6000 3500 11600 8800 7350 5300 4500 2800 10 355 250 200 0.30 19 6.8 355 250 200 0.30 19 10.3 500 315 250 0.28 27.7 11.7 500 400 315 0.28 27.7 17.5 630 500 425 0.28 56.7 26.7 1250 630 500 0.15 54.3 26.5 1250 800 630 0.13 63.7 45.3 1250 1000 800 0.14 140 68.6 2x800 1250 1000 0.11 171.8 74.8 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 CK07B CK08B CK09B CK95B CK10C CK11C CK12B CK13B Three pole contactors Technical data Rated thermal current Ith at e ) 40ºC (A) Rated operational current Ie AC-3 (A) Rated operational voltage Ue (V) Rated insulation voltage Ui (V) Maximum continuous current AC-1 (A) Frequency limits (Hz) Making capacity (RMS) (IEC 947) (A) Breaking capacity (RMS) (IEC 947) Ue ) 400V (A) Ue = 500V (A) Ue = 690V (A) Ue = 1000V (A) Short-time current 1 sec. (A) 5 sec. (A) 10 sec. (A) 30 sec. (A) 1 min. (A) 3 min. (A) Short-time current (min.) Protec. against short-circuit with fuses without TOR Coord. type “1” gL/gG (A) Coord. type "2" gL/gG (A) Without welding gL/gG (A) Impedance per pole (m1) Power dissipation AC-1 (W) per pole AC-3 (W) Insulation resistance Between adjacent poles (m1) Between poles and earth (m1) Between input and output (m1) Intro A B Four pole contactors Rated thermal current Ith at e ) 40ºC (A) Rated operational voltage Ue (V) Rated insulation voltage Ui (V) Maximum continuous current AC-1 (A) Frequency limits (Hz) Making capacity (RMS) (IEC 947) (A) Breaking capacity (RMS) (IEC 947) Ue ) 400V (A) Ue = 500V (A) Ue = 690V (A) Ue = 1000V (A) Short-time current 1 sec. (A) 5 sec. (A) 10 sec. (A) 30 sec. (A) 1 min. (A) 3 min. (A) Recovery time min. Short-circuit protection with fuse without TOR Coord. type "1" gL/gG (A) Coord. type “2” gL/gG (A) Without welding gL/gG (A) Impedance per pole (m1) Power dissipation per pole AC-1 (W) Insulation resistance Between adjacent poles (m1) Between poles and earth (m1) Between input and output (m1) 200 690 1000 200 25...400 1150 325 1000 1000 325 25...4000 1850 400 1000 1000 400 25...400 2500 500 1000 1000 500 25...400 3700 600 1000 1000 600 25...400 6500 700 1000 1000 700 25...400 6500 1000 1000 1000 1000 25...400 6700 1250 1000 1000 1250 25...400 8250 950 950 800 – 2100 1500 1150 750 550 350 10 1600 1600 1000 350 2500 2500 2300 1250 900 600 10 3500 3500 2200 1100 5500 3500 2500 1600 1200 900 10 3500 3500 2200 1100 5500 3500 2500 1600 1200 900 10 5600 5600 3500 2000 7500 5200 4000 2800 1800 1200 10 5600 5600 3500 2000 7500 5200 4000 2800 1800 1200 10 6700 6700 6000 3500 9700 7700 6100 4400 3500 2300 10 6600 6600 6000 3500 11600 8800 7350 5300 4500 2800 10 315 250 200 0.45 500 400 315 0.32 500 400 315 0.28 630 500 425 0.28 1250 630 500 0.15 1250 800 630 0.13 1250 1000 800 0.14 2x800 1250 1000 0.11 18 33.8 44.8 56.7 61.2 68.6 140 171.8 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 C D E F G H I J/X A.103 Series CK Electrical endurance Mixed category AC4 / AC3 Electrical endurance for mixed category (AC-3/AC-4) is calculated with the following formula: Electrical endurance (AC-3/AC-4) Electrical endurance (AC-3) = 1+ Contactors Category AC1 Number of operations Intro A Ic=Ie for all voltages B C D Category AC2 Number of operations E F G H J/X A.104 . I Rated motor power (Ic = 2.5 Ie) % oper AC-4 100 X (AC-3) -1 ) ( Elec.endur. Elec.endur.(AC-4) Series CK Electrical endurance (continued) Category AC3 Number of operations . Technical data Rated motor power (Ic = Ie) Intro A B Category AC4 C D Number of operations E F G . H Rated motor power (Ic = 6 Ie) I J/X A.105 Series CK Three pole contactors. Control circuit Contactors Alternating current Intro A B C Rated insulation voltage Ui (V) Standard voltages Us (50/60 Hz) (V) Operating limits Switch-on xUs Switch-off xUs Consumption. Monofrequency coils Magnetic circuit CK....A (VA) closed CK....E (VA) Magnetic circuit CK....A (VA) open CK....E (VA) Power CK....A (W) dissipation CK....E (W) Consumption. Bifrequency coils Magnetic circuit 50Hz (VA) closed (CK....A) 60Hz (VA Magnetic circuit 50Hz (VA) open (CK....A) 60Hz (VA) Power 50Hz (W) dissipation (CK....A) 60Hz (W Power factor Magnetic circuit CK....A (cos ) closed CK....E (cos ) Magnetic circuit CK....A (cos ) open CK....E (cos ) Opening and closing times at Us Making time (ms) at excitation (NO) Breaking time (ms) at de-energisation (NO) 106 ops Mechanical endurance (1) Maximum rate No load ops./h AC-1/AC-3 at rated power ops./h AC-2 at rated power ops./h AC-4 at rated power ops./h CK75CA CK08CA CK85BA CK85BE CK09BE CK95BE CK10CE CK11CE CK12BE CK12BE CK13BA 1000 24...690 1000 24...690 1000 24...690 1000 24...690 1000 24...690 1000 24...690 1000 24...690 1000 24...72 1000 100...690 1000 24...440 0.8...1.1 0.2...0.75 0.8...1,1 0.2...0.75 0.85...1.1 0.2...0.75 0.85...1,1 0.2...0.75 0.85...1.1 0.2...0.75 0.85...1.1 0.2...0.75 0.85...1.1 0.2...0.75 0.85...1.1 0.2...0.75 0.85...1.1 0.2...0.75 0.8...1.1 0.25...0.55 42 500 21 - 42 500 21 - 46 20 830 425 17 3.5 20 425 3.5 20 425 3.5 23 680 4 23 680 4 25 750 4.5 25 750 4.5 6 2760 5 - 46 38.3 568 473 23 19.1 46 38.3 568 473 23 19.1 60 50 1082 901 22.2 18.5 - - - - - - - 0.4 0.6 - 0.4 0.6 - 0.37 0.6 - - - - - - - approx. 1 approx. 1 - 20...25 20...25 36...40 60...70 60...80 80...90 80...90 150...170 70...80 50...55 10...13 10...13 60...80 60...80 60...80 60...80 60...90 60...90 60...90 115...130 10 10 6.5 6.5 6.5 7.5 7.5 3.5 3.5 3 2400 600 150 150 2400 600 150 150 2400 600 150 150 1200 600 150 150 1200 600 150 150 900 300 120 120 900 300 120 120 900 300 120 120 900 300 120 120 600 120 120 120 (1) Mechanical endurance for e-module is 1 Million operations D E F G H I J/X A.106 Direct current Rated insulation voltage Ui (V) Standard voltages Us (50/60 Hz) (V) Operating limits Switch-on xUs Switch-off xUs Consumption Magnetic circuit closed (W) Magnetic circuit open (W) Opening and closing times at Us Making time (ms) at excitation (NO contacts) Breaking time (ms) at de-energisation (NO contacts) Mechanical endurance 106 ops. Maximum rate No load ops./h AC-3 at rated power ops./h AC-4 at rated power ops./h CK75CE CK08CE CK85BE CK09BE CK95BE CK10CE CK11CE CK12BE CK12BE 1000 24...500 1000 24...500 1000 24...500 1000 24...500 1000 24...500 1000 24...500 1000 24...500 1000 24...72 1000 110...500 0.8...1.1 0.2...0.75 0.8...1.1 0.2...0.75 0.8...1.1 0.2...0.75 0.8...1.1 0.2...0.75 0.8...1.1 0.2...0.75 0.8...1.1 0.2...0.75 0.8...1,1 0.2...0.75 0.8...1.1 0.2...0.75 0.8...1.1 0.2...0.75 10 225 10 225 10 350 10 350 10 350 10 500 10 500 10 650 10 650 60...70 60...70 60...70 60...70 60...70 80...90 80...90 150...170 70...80 40...50 40...50 60...80 60...80 60...80 60...80 60...80 60...90 60...90 10 10 6.5 6.5 6.5 7.5 7.5 3.5 3.5 1200 600 150 1200 600 150 1200 600 150 1200 600 150 1200 600 150 900 300 120 900 300 120 900 300 120 900 300 120 (1) Mechanical endurance for e-module is 1 Million operations Series CK Four pole contactors. Control circuit Alternating current CK08BA CK08BE CK09BE CK95BE CK10CE CK11CE CK12BE CK12BE CK13BA 1000 24...690 1000 24...690 1000 24...690 1000 24...690 1000 24...690 1000 24...690 1000 24...72 1000 100...690 1000 110...440 0.85...1.1 0.2...0.75 0.85...1.1 0.2...0.75 0.85...1.1 0.2...0.75 0.85...1.1 0.2...0.75 0.85...1.1 0.2...0.75 0.85...1.1 0.2...0.6 0.85...1.1 0.2...0.75 0.85...1.1 0.2...0.75 0.85...1.1 0.2...0.75 46 20 830 425 17 3.5 130 25 2860 750 53 4.5 25 750 4.5 25 750 4.5 23 680 4 23 680 4 25 750 4.5 25 750 4.5 6 2760 5 - 60 50 1082 901 22.2 18.5 159.3 132.7 3509 2924 65.3 54.4 - - - - - - - 0.37 0.6 - 0.37 0.6 - - - - - - - approx. 1 approx. 1 - 36...40 60...70 70...80 70...80 110...115 80...90 150...170 110...115 50...55 10...15 13...17 70...80 70...80 70...80 70...80 70...80 70...80 70...80 10 6.5 6.5 6.5 6.5 6.5 3.5 3.5 3 2400 600 900 600 900 600 900 600 900 300 900 300 900 300 900 300 600 120 (1) Mechanical endurance for e-module is 1 Million operations Technical data Rated insulation voltage Ui (V) Standard voltages Us (50/60 Hz) (V) Operating limits Switch-on xUs Switch-off xUs Consumption. Monofrequency coils Magnetic circuit CK....A (VA) closed CK....E (VA) Magnetic circuit CK....A (VA) open CK....E (VA) Power CK....A (W) dissipation CK....E (W) Consumption. Bifrequency coils Magnetic circuit 50Hz (VA) closed (CK....A) 60Hz (VA) Magnetic circuit 50Hz (VA) open (CK....A) 60Hz (VA) Power 50Hz (W) dissipation (CK....A) 60Hz (W) Power factor Magnetic circuit CK....A (cos ) closed CK....E (cos ) Magnetic circuit CK....A (cos ) open CK....E (cos ) Opening and closing times at Us Making time (ms) at excitation (NO) Breaking time (ms) at de-energisation (NO) Mechanical endurance 106 ops. Maximum rate No load ops./h AC-1/AC-3 at rated power ops./h CK07BA CK07BE Intro A B C D Direct current - Electronic module Rated insulation voltage Ui (V) Standard voltages Us (V) Operating limits Switch-on xUs Switch-off xUs Consumption Magnetic circuit closed (W) Magnetic circuit open (W) Opening and closing times at Us Making time (ms) at excitation (NO contacts) Breaking time (ms) at de-energisation (NO contacts) Mechanical endurance 106 ops. Maximum rate No load ops./h AC-3 at rated power ops./h CK07BE CK08BE CK08BE CK95BE CK10CE CK11CE CK12BE CK12BE 1000 24...500 1000 24...500 1000 24...500 1000 24...500 1000 24...500 1000 24...500 1000 24...72 1000 110...500 0.75...1.1 0.2...0.75 0.8...1.1 0.2...0.75 0.8...1.1 0.2...0.75 0.8...1.1 0.2...0.75 0.8...1.1 0.2...0.75 0.8...1.1 0.2...0.75 0.8...1.1 0.2...0.75 0.8...1.1 0.2...0.75 10 350 10 650 10 650 10 650 10 650 10 650 10 650 10 650 60...70 70...80 70...80 70...80 80...90 80...90 150...170 110...115 40...50 70...80 70...80 70...80 60...80 60...80 60...90 60...90 10 6.5 6.5 6.5 6.5 6.5 3.5 3.5 1200 600 900 600 900 600 900 600 900 600 900 300 900 300 900 300 (1) Mechanical endurance for e-module is 1 Million operations E F G H I J/X A.107 Series CK Contact sequence Basic contactor Auxiliary contact blocks Lateral mounted BCLL 20 BRLL 20 Three-pole CK75C... contactors CK08C... 3 NO 0 CK85B... CK09B... CK95B... 0 10.4 14 0 CK10C... CK11C... 0 12 17 0 3.5 CK12B... CK13B... 0 12.6 17.5 0 3.5 CK07B... 0 7.7 10.7 0 CK08B... CK09B... CK95B... 0 10.4 14 0 CK10C... CK11C... 0 12 17 0 3.5 CK12B... CK13B... 0 12.6 17.5 0 3.5 7.3 10.4 0 3.5 BCLL 11 BRLL 11 10.4 0 14 0 17 0 3.5 10.4 1,8 3.5 3.5 14 1,8 3.5 17 Contactors 1.8 17.5 0 3.5 17.5 1.8 3.5 10.7 0 3.5 10.7 3.5 14 1.8 Intro 3.5 14 0 17 0 1.8 3.5 17 1.8 A 17.5 0 3.5 17.5 1.8 B Numbering of the terminals C D Three pole contactors Four pole contactors CK75C_ _3_ ... CK13B _ _3_ CK07B_ _4_ ... CK13B _ _4_ Auxiliary contact blocks. Lateral mounting Voltage suppressor block BCLL20 BCLL11 K/RC... BRLL20 BRLL11 E F G H I J/X A.108 Mechanical interlock BEKV, BEKVA1, BEKVS1, BEKVH Series CK Dimensional drawings Three pole contactors CK75C CK08C 3.500 kg 3.500 kg . . . . . Contactors . CK85B CK09B CK95B 6.100 kg 6.200 kg 6.300 kg CK10C CK11C 11.00 kg 11.00 kg Intro A B C D CK12B 18.00 kg E F G H I J/X A.118 CK13B 35.00 kg Series CK Four pole contactors CK07B Mechanical interlock . 4.700 kg BEKH 0.350 kg CK75C3... - CK08C3... CK85B3... - CK95B3... CK10C3... - CK11C3... CK12B3... Dimensions CK08B CK09B CK95B A 55 55 33 75 14.90 kg 15.10 kg 15.30 kg A CK10C CK11C BEKVA1 BEKVS1 22.30 kg 22.80 kg Intro 550 0.900 kg 350 0.800 kg A B C CK12B D 23.30 kg E BEKV 1.200 kg F G CK13B H 44.00 kg I J/X . . A.119