SERIES CL - CK - Contactors Contactors Series CL � � � � � A=AC D=DC E=DC/AC with electronic module � � Type identification � � ➀ Contactor (see K.11) ➁ Auxiliary contacts side-mounted (see K.15) ➂ Mechanical interlock (see K.15) ➃ Auxiliary contacts front-mounted (see K.15) ➄ Electronic timer block (see K.16) ➅ Transient voltage suppressor block (see ie K.16) ➆ Mechanical latch block (see K.15) ➇ Pneumatic timer block (see K.15) ➈ Thermal overload relay (see K.22) � C Housing 00 05 01 06 02 07 25 08 03 09 04 10 45 Auxiliary contacts NO Auxiliary contacts NC Control voltage L 3 = 3-pole 4 = 4-pole NO B = 4-pole 2NO + 2NC T = screw terminal M = double clamp terminal Contactors Series CK Type identification C A=AC E=DC/AC with electronic module Housing 07 10 75 11 08 12 85 13 09 95 Auxiliary contacts NO Auxiliary contacts NC Control voltage K Version (B, C) 3 = 3-pole 4 = 4-pole (4NO) Thermal overload relay RT Type identification R Setting range (A...W) T Housing 2 = class 10A (RT1) class 10 (RT2, RT3, RT4, RT5, RT6) = class 20 (RT1. RT2. RT3) L = class 30 – (RT4, RT5, RT6) K 5 SERIES CK - Contactors Three- and four-pole contactors – Control circuit: Alternating current up to 690V Direct current up to 500V – Power circuit up to 1000V AC – Degree of protection: IP00 – CK07...CK13: auxiliary and coil terminals originally protected against accidental contacts. Protection for power contacts on request (see accessories). – CK...E with electronic module suitable for DC and AC (50/60 Hz) CK08CA... CK09BE... Three-pole contactors from 150 to 825A (AC3) Maximum operating current Noninductive load Admissible power AC3 Electrical Control Aux. endurance circuit cont AC1 Motors 220V 380V 415V 440V 500V ≤ 440V, 230V 400V 3-phase 50/60 Hz AC3 AC3 A A kW kW kW kW kW 250 150 45 75 80 100 1.7 x 106 80 •4 •2 # ops. 100 100 110 1.2 x 106 185 55 90 315 205 65 110 125 125 132 1.7 x 106 315 450 600 700 1000 1250 250 309 420 550 700 825 75 90 125 160 220 250 132 160 220 280 375 450 132 185 230 315 425 450 160 200 300 400 480 500 Pack Weight • 3 •1 250 132 160 230 315 400 450 Cat. no.(1) 1.5 x 106 1.1 x 106 1 x 106 0.8 x 106 0.7 x 106 0.7 x 106 AC/DC(2) AC/DC(3) AC/DC(2) AC/DC(3) AC/DC(2) AC/DC(3) AC/DC(3) AC/DC(3) AC/DC(3) AC/DC(3) AC/DC(3) AC/DC(2) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 CK75CA311 CK75CE311 CK08CA311 CK08CE311 CK85BA311 CK85BE311 CK09BE311 CK95BE311 CK10CE311 CK11CE311 CK12BE311 CK13BA311 ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ 1 1 1 1 1 1 1 1 1 1 1 1 3.4 3.5 3.4 3.5 5.9 6.1 6.2 6.3 11 11 18 35 Four-pole contactors from 200 to 1250A (AC1) Electrical Control Aux. Cat. no.(1) endurance circuit cont. Max. oper. Admissible power current AC3 AC1 Noninductive load AC1 380V 400V 220V 380V 415V 440V 500V 230V 400V A kW A 200 55 105 76 (2) (3) • 3 •1 •4 •2 AC1 kW kW kW kW kW # ops. 131 143 151 173 1 x 106 CK12BE... 325 100 185 123 214 233 247 281 0.6 x 106 400 500 600 700 1000 1250 132 160 220 280 375 450 250 309 408 530 680 800 152 191 228 266 381 476 263 329 395 460 658 822 287 359 431 503 719 898 304 380 456 533 762 952 Pack Weight 346 415 519 606 866 1082 0.6 x 106 0.6 x 106 0.5 x 106 0.4 x 106 0.4 x 106 0.6 x 106 AC/DC(2) AC/DC(3) AC /DC(2) AC/DC(3) AC/DC(3) AC/DC(3) AC/DC(3) AC/DC(3) AC/DC(3) AC/DC(2) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 CK07BA411 CK07BE411 CK08BA411 CK08BE411 CK09BE411 CK95BE411 CK10CE411 CK11CE411 CK12BE411 CK13BA411 CK13BA... ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ 1 1 1 1 1 1 1 1 1 1 4.7 4.8 14.8 14.9 15.1 15.3 22.3 22.8 23.3 44 Available coil voltages Alternating current (V). For contactors types CK75CA... to CK85BA... ◆ C 50 Hz 60 Hz D 24 24 F 42 48 G 48 H I J K 110 127 110 120 M N R S T U V W X Y Z 220 240 380 415 440 500 660 230 400 690 220 277 240 380 480 440 600 Alternating current / direct current with electronic module (V). (for types CK...E) (0.80 ... 1.10 x Us) Direct current with electronic module. For types CK75CE... and CK08CE... (0.70 ... 1.30 x Us) (4) ◆ ◆ 50/60 Hz D 24 28 F J N U Y 42 110 220 380 440 48 127 250 415 500 Voltage WD WE WF WH WJ WN 24 33 48 72 110 220 Alternating current (V). For contactors type CK13BA... Spare coils, see K.20 Thermal overload relays, see K.23 Technical specifications, see K.47 Dimensions, see K.53 (1) To complete the catalogue number, replace the symbol ◆ by the corresponding code. (2) CK...A only for AC control. (3) CK...E with electronic module: AC (50/60 Hz) and DC control. (4) Maximum number of auxiliary contacts : four ◆ 50 Hz 60 HZ J N U 110 220 380 240 440 SERIES CK - Accessories BCLL Side mounted auxiliary contact blocks – – – – Terminals protected against accidental contacts in accordance with VDE 0106 T.100, VBG4: IP2x. Terminal numbering in accordance with EN 50005 CK-contactors always provided with one auxiliary contact block 1 NO + 1 NC Up to four side mounted auxiliary contact blocks and combinations (2 on the left + 2 on the right) for max. eight contacts. Mounting Aux. contacts •3 •4 Side (left or right) Side, combinations of more than 2 blocks K/RC-24 2 1 2 1 Cat. no. Pack Weight •1 •2 0 1 0 1 BCLL20 BCLL11 BRLL20 BRLL11 10 10 10 10 0.048 0.048 0.048 0.048 Transient voltage suppressor Directly connected parallel to the coil terminals A1-A2 For use with CK75...CK08... CK 85...CK13... BEKVA Ue 24V-48V AC 50V - 127V AC 130V - 240V AC 227V - 500V AC 24V AC 260V AC 415V AC Cat. no. Pack Weight BSLR3G 10 0.020 BSLR3K 10 0.020 BSLR3R 10 0.020 BSLV3U 10 0.050 K/RC-24 10 0.050 K/RC-48/260 10 0.050 K/RC-380/415 10 0.050 Mounting Horizontal Vertical Vertical Vertical Cat. no. BEKH BEKVS BEKVA BEKV Pack Weight Cat. no. (1) CM1CA5F C09476 C09479 Pack Weight Mechanical interlock For use with CK07B...CK12... CK07B...CK95... CK10C...CK12B... CK13... 1 1 1 1 0.350 0.800 0.900 1.200 Pole terminal protection IPxxB For use with CK75C... – CK08C... CK85B.3. – CK12B.3. CK85B.4. – CK12B.4. (1) Under development Mounting Single pole VDE0106 Single pole VDE0106 Single pole VDE0106 1 6 8 0.150 0.250 0.300 SERIES CK - Accessories Alternating current without electronic module Coils KB5E◆ + KM5E◆ CK...A For use with CK75CA3...CK08CA3... CK85BA3...CK07BA4... CK08BA4... CK13BA3...CK13BA4... Cat. no.(1) Pack Weight C12168 ◆ 1 0.415 1 0.450 C04255 ◆ 1 1.540 C04787 ◆ 1 1.200 C08998 ◆ Available coil voltages (V) ◆ C D F G 24 42 48 24 48 50 Hz 60 Hz H I J K M N S T 110 127 220 230 110 120 220 277 240 380 U V W X Y Z 380 415 450 550 660 400 690 480 440 600 Control circuit with incorporated rectifier bridge CK...A For use with CK13BA3...CK13BA4... Cat. no.(1) Pack Weight C09120 ◆ 1 0.800 Available coil voltages (V) ◆ 50 Hz 60 Hz J N U 110 220 380 230 400 120 240 480 Direct current or alternating current 50/60 Hz, with electronic module CK...E Coil Electronic module For use with CK75CE3...CK08CE3... CK85BE3...CK09BE3...CK95BE3... CK07BE4... CK12BE3... CK08BE4...CK09BE4...CK95BE4...CK12BE4... Cat. no.(1) Pack Weight KB4E ◆ 1 0.415 1 0.470 KB5E ◆ KB6E ◆ 1 0.470 CK10CE3...CK11CE3... CK10CE4...CK11CE4... CK75CE3...CK08CE3... CK85BE3...CK09BE3...CK95BE3... CK07BE4... CK12BE3... CK08BE4...CK09BE4...CK95BE4...CK12BE4... KB7E ◆ 1 0.470 KM4E ◆ KM5E ◆ 1 1 0.140 0.140 KM6E ◆ 1 0.140 CK10CE3...CK11CE3... CK10CE4...CK11CE4... KM7E ◆ 1 0.140 Available coil voltages (V) AC/DC ◆ Voltage Contact kits V1107BA D F J N U Y 24 42 110 220 380 440 28 48 127 250 415 500 For use with CK07B... CK75C... CK08C... CK08B...(4 pole) CK85B... CK09B... CK09B...(4 pole) CK95B... CK10C... CK11C... CK12B... CK13B... Number of sets 1 1 1 1 1 1 1 1 1 1 1 1 (1)To complete the catalogue number, replace the symbol ◆ by the code corresponding to the voltage and frequency of the control circuit. Type NO NO NO NO NO NO NO NO NO NO NO NO Cat. no. (2) V1107BA V1175CA V1108CA V1108B4 V1185BA V1109BA V1109B4 V1195BA V1110CE V1111CE V1112BA V1113BA Pack Weight 1 1 1 1 1 1 1 1 1 1 1 1 0.144 0.160 0.160 0.160 0.360 0.360 0.360 0.400 0.650 0.650 1.400 2.500 (2)One set consists of two fixed contacts, one moving con tact and accessory parts. When contact replacement is needed, it is recommended to replace all the contacts at the same time. SERIES CK - Technical data General Conformity to standards IEC 947-1 CENELEC HD 419 CEI EN 60947-4-1 UL 508 EN 50005 IEC 947-4-1 NF C 63-110 ASE 1025 CSA 22.2/14 UNE 20109 Terminal capacity and tightening torque BS 5424 & 775 NEMA ICS 1 VDE 0660/102 Approvals UL CSA RINA NOM FI Lloyds’ Register of Shipping Bureau Veritas Solid Finely stranded with end sleeve Finely stranded without end sleeve Stranded AWG wires Tightening torque CK07B (mm2) 1.5...95 (mm2) 2...35 (mm2) 2...50 (mm2) 1.5...95 (mm2) 16...00 8 Nm 70 Lb x in Ambient conditions Storage temperature Operation temperature Operating altitude up to 3,000 m Operating altitude from 3,000 to 4,000 m Operating altitude from 4,000 to 5,000 m – 55°C to + 80°C – 40°C to + 60°C Nominal values 90 % Ie 80 % Ue 80 % Ie 75 % Ue CK07B Climatic resistance IEC 68-2 Continuous tests Cold – Temperature – Time Dry heat – Temperature – Relative humidity – Time Humid heat – Temperature – Relative humidity – Time 40/125/56 Cyclical tests First half-cycle – 40°C – Low temperature + 25°C 72 h – Relative humidity 93 % – Time 12 h + 125°C Second half-cycle ≤ 50 % – Low temperature + 55 % 96 h – Relative humidity 95 % – Time 12 h + 40°C Number of consecutive cycles 6 95 % 56 days Mounting positions Finely stranded with end sleeve AWG wires with end sleeve Busbars Tightening torque Finely stranded with end sleeve AWG wires with end sleeve Busbars Tightening torque With the same pick-up and drop-out voltages With the same rated power CK75C to CK13B (mm2) (mm2) (Nm) (Lb x in) CK75C CK08C 1 x 120 2 x 95 1 x 300 2 x 107 2 (25 x 5) 8 70 CK11C (mm2) 2 x 240 (mm2) 2 x 500 2 (35 x 10) (Nm) 31.5 (Lb x in) 275 CK08B to CK10C CK95B 1 x 240 2 x 185 2 x 150 1 x 500 2 x 350 2 x 300 2 (25 x 5) 2 (35 x 10) 23 31.5 200 275 CK12B – CK13B – – 2 (35 x 10) 31.5 275 – 2 (60 x 10) 31.5 275 SERIES CK - Technical data Power circuit Three-pole contactors Rated thermal current Ith at θ ≤ 40°C Rated operational current Ie AC3 Rated operational voltage Ue Rated insulation voltage Ui Maximum continuous current AC1 Frequency limits Making capacity (RMS) Breaking capacity (RMS) Ue ≤ 400V Ue = 500V Ue = 690V Ue = 1000V Short-time current 1 sec. 5 sec. 10 sec. 30 sec. 1 min. 3 min. Recovery time Short-circuit protection with fuse Coordination type "2" aM gl-gG Impedance per pole Power dissipation per pole AC1 AC3 Insulation resistance Between adjacent poles Between poles and earth Between input and output CK75C 250 150 1000 1000 250 25...400 1850 CK08C 250 185 1000 1000 250 25...40 1850 CK85B 315 205 1000 1000 315 25...400 2500 CK09B 315 250 1000 1000 315 25...400 2500 CK95B 450 309 1000 1000 450 25...400 3700 CK10C 600 420 1000 1000 600 25...400 6500 CK11C 700 550 1000 1000 700 25...400 6500 CK12B 1000 700 1000 1000 1000 25...400 8400 CK13B 1250 825 1000 1000 1250 25...400 8250 (A) (A) (A) (A) 1600 1600 1000 350 1600 1600 1000 350 2000 2000 1660 850 3500 3500 2200 1100 3500 3500 2200 1100 5600 5600 3500 2000 5600 5600 3500 2000 7300 7000 6700 3500 6600 6600 6000 3500 (A) (A) (A) (A) (A) (A) (min.) 2500 2500 2300 1250 900 600 10 2500 2500 2300 1250 900 600 10 4000 3200 2400 1400 1000 750 10 5500 3500 2500 1600 1200 900 10 5500 3500 2500 1600 1200 900 10 7500 5200 4000 2800 1800 1200 10 7500 5200 4000 2800 1800 1200 10 9700 7700 6100 4400 3500 2300 10 11600 8800 7350 5300 4500 2800 10 (A) (A) (mΩ) 160 250 0.30 200 250 0.30 250 315 0.28 250 400 0.28 315 500 0.28 400 630 0.15 500 800 0.13 630 1000 0.14 1000 1250 0.11 19 6.8 19 10.3 27.7 11.7 27.7 17.5 56.7 26.7 54.3 26.5 63.7 45.3 140 68.6 171.8 74.8 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 (A) (A) (V) (V) (A) (Hz) (A) (W) (W) (MΩ) (MΩ) (MΩ) Four-pole contactors Rated thermal current Ith at θ ≤ 40°C Rated operational voltage Ue Rated insulation voltage Ui Maximum continuous current AC1 Frquency limits Making capacity (RMS) Breaking capacity (RMS) Ue ≤ 400V Ue = 500V Ue = 690V Ue = 1000V Short-time current 1 sec. 5 sec. 10 sec. 30 sec. 1 min. 3 min. Recovery time Short-circuit protection with fuse Coordination type "2" gL-gG Impedance per pole Power dissipation per pole AC1 Insulation resistance Between adjacent poles Between poles and earth Between input and output CK07B 200 690 1000 200 25...400 1150 CK08B 325 1000 1000 325 25...4000 1850 CK09B 400 1000 1000 400 25...400 2500 CK95B 500 1000 1000 500 25...400 3700 CK10C 600 1000 1000 600 25...400 6500 CK11C 700 1000 1000 700 25...400 6500 CK12B 1000 1000 1000 1000 25...400 6700 CK13B 1250 1000 1000 1250 25...400 8250 950 950 800 – 1600 1600 1000 350 3500 3500 2200 1100 3500 3500 2200 1100 5600 5600 5000 300 5600 5600 5000 300 6700 6700 6000 3500 6600 6600 6000 3500 (A) (A) (A) (A) (A) (A) (min.) 2100 1500 1150 750 550 350 10 2500 2500 2300 1250 900 600 10 5500 3500 2500 1600 1200 900 10 5500 3500 2500 1600 1200 800 10 7500 5200 4000 2800 1800 1200 10 7500 5200 4000 2800 1800 1200 10 9700 7700 6100 4400 3500 2300 10 11600 8800 7350 5300 4500 2800 10 (A) (mΩ) 250 0.45 400 0.32 500 0.28 500 0.28 630 0.15 800 0.13 1000 0.14 1250 0.11 18 33.8 44.8 56.7 61.2 68.6 140 171.8 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 > 10 (A) (V) (V) (A) (Hz) (A) (A) (A) (A) (A) (W) (MΩ) (MΩ) (MΩ) SERIES CK - Technical data Control circuit Three-pole contactors Alternating current Rated insulation voltage Ui (V) Standard voltages Us (50/60 Hz) (V) Operating limits Switch-on xUs Switch-off xUs Consumption Seal (VA) Pick-up (VA) Power dissipation (W) Power factor Seal (cos ϕ) Pick-up (cos ϕ) Opening and closing times at Us Making time at excitation (NO contacts) (ms) Breaking time at desexcitation (NO contacts) (ms) Mechanical endurance 106 ops. Maximum rate No load ops./h AC1/AC3 at rated power ops./h AC2 at rated power ops./h AC4 at rated power ops./h Direct current Rated insulation voltage Ui (V) Standard voltages Us (50/60 Hz) (V) Operating limits Operating xUs Drop-out xUs Consumption Seal (W) Pick-up (W) Opening and closing times at Us Making time at excitation (NO contacts) (ms) Breaking time at desexcitation (NO contacts) (ms) Mechanical endurance 106 ops. Maximum rate No load ops./h AC3 at rated power ops./h AC4 at rated power ops./h CK75C 1000 24...690 CK08C 1000 24...690 CK85B 1000 24...690 CK09B 1000 24...690 CK95B 1000 24...690 CK10C 1000 24...690 CK11C 1000 24...690 CK12B 1000 24...690 CK13B 1000 24...440 0.8...1.1 0.5...0.6 0.8...1.1 0.5...0.6 0.8...1.1 0.5...0.6 0.8...1.1 0.4...0.6 0.8...1.1 0.4...0.6 0.8...1.1 0.4...0.6 0.8...1.1 0.4...0.6 0.8...1.1 0.4...0.6 0.8...1.1 0.2...0.4 32 400 13 32 400 13 60 830 22.2 60 830 3.5 13 340 3.5 23 680 4 23 680 4 25 750 4.5 6 2760 6 0.4 0.6 0.4 0.6 0.37 0.6 - - - - - approx. 1 approx. 1 20...25 10...13 10 20...25 10...13 10 36...40 10...15 10 60...70 13...17 10 60...70 13...17 10 80...90 40...50 10 80...90 40...50 10 70...80 70...80 10 50...55 115...130 3 2400 600 250 150 2400 600 250 150 2400 600 250 150 1200 600 250 150 1200 600 250 150 900 300 200 120 900 300 200 120 900 300 200 120 600 120 120 120 CK75C 1000 24...500 CK08C 1000 24...500 CK85B 1000 24...500 CK09B 1000 24...500 CK95B 1000 24...500 CK10C 1000 24...500 CK11C 1000 24...500 CK12B 1000 24...500 0.75...1.1 0.75...1.1 0.75...1.1 0.8...1.1 0.35...0.5 0.35...0.5 0.35...0.5 0.4...0.6 0.8...1.1 0.4...0.6 0.8...1.1 0.4...0.6 0.8...1.1 0.4...0.6 0.8...1.1 0.4...0.6 2 135 2 135 3.5 350 3.5 350 3.5 350 4 600 4 600 4.5 650 60...70 13...17 10 60...70 13...17 10 60...70 13...17 10 60...70 13...17 10 60...70 13...17 10 80...90 40...50 10 80...90 40...50 10 70...80 40...50 10 1200 600 150 1200 600 150 1200 600 150 1200 600 150 1200 600 150 900 300 120 900 300 120 900 300 120 SERIES CK - Technical data Four-pole contactors Alternating current Rated insulation voltage Ui (V) Standard voltages Us (50/60 Hz) (V) Operating limits Switch-on xUs Switch-off xUs Consumption Seal (VA) Pick-up (VA) Power dissipation (W) Power factor Seal (cos ϕ) Pick-up (cos ϕ) Opening and closing times at Us Making time at excitation (NO contacts) (ms) Breaking time at desexcitation (NO contacts) (ms) Mechanical endurance 106 ops. Maximum rate No load ops./h AC1/AC3 at rated power ops./h Direct current Rated insulation voltage Ui (V) Standard voltages Us (V) Operating limits Switch-on xUs Switch-off xUs Consumption Seal (W) Pick-up (W) Opening and closing times at Us Making time at excitation (NO contacts) (ms) Breaking time at desexcitation (NO contacts) (ms) Mechanical endurance 106 ops. Maximum rate No load ops./h AC3 at rated power ops./h CK07B 1000 24...690 CK08B 1000 24...690 CK09B 1000 24...690 CK95B 1000 24...690 CK10C 1000 24...690 CK11C 1000 24...690 CK12B 1000 24...690 CK13B 1000 110...440 0.8...1.1 0.5...0.6 0.8...1.1 0.5...0.6 0.8...1.1 0.4...0.6 0.8...1.1 0.4...0.6 0.8...1.1 0.4...0.6 0.8...1.1 0.4...0.6 0.8...1.1 0.4...0.6 0.8...1.1 0.2...0.6 60 830 22.2 130 2860 18 25 750 4.5 25 750 4.5 25 750 4.5 23 680 4 25 750 4.5 25 2760 6 0.37 0.6 0.37 0.6 - - - - - approx. 1 approx. 1 36...40 10...15 10 60...70 13...17 10 70...80 70...80 10 70...80 70...80 10 110...115 80...90 70...80 40...50 10 10 110...115 50...55 70...80 70...80 10 3 2400 600 900 600 900 600 900 600 900 300 900 300 900 300 CK07B 1000 24...500 CK08B 1000 24...500 CK09B 1000 24...500 CK95B 1000 24...500 CK10C 1000 24...500 CK11C 1000 24...500 CK12B 1000 24...500 0.75...1.1 0.8...1.1 0.35...0.5 0.4...0.6 0.8...1.1 0.4...0.6 0.8...1.1 0.4...0.6 0.8...1.1 0.4...0.6 0.8...1.1 0.4...0.6 0.8...1.1 0.4...0.6 3.5 350 4.5 650 4.5 650 4.5 650 4.5 650 4.5 650 4.5 650 60...70 13...17 10 70...80 70...80 10 70...80 70...80 10 70...80 70...80 10 80...90 40...50 10 80...90 40...50 10 110...115 70...80 10 1200 600 900 600 900 600 900 600 900 600 900 300 900 300 600 120 SERIES CK - Dimensional drawings Three-pole contactors CK75C CK08C CK85B CK09B CK95B CK10C CK11C CK12B CK13B SERIES CK - Dimensional drawings Four-pole contactors CK07B CK08B CK09B CK95B CK10C CK11C CK12B CK13 Mechanical interlock BEKH BEKV A BEKVS 550 BEKVA 350 A