SERIES CL - CK - Contactors
Contactors Series CL
�
�
�
�
�
A=AC
D=DC
E=DC/AC with electronic module
�
�
Type
identification
�
�
➀ Contactor (see K.11)
➁ Auxiliary contacts side-mounted (see K.15)
➂ Mechanical interlock (see K.15)
➃ Auxiliary contacts front-mounted (see K.15)
➄ Electronic timer block (see K.16)
➅ Transient voltage suppressor block (see ie K.16)
➆ Mechanical latch block (see K.15)
➇ Pneumatic timer block (see K.15)
➈ Thermal overload relay (see K.22)
�
C
Housing
00 05
01 06
02 07
25 08
03 09
04 10
45
Auxiliary
contacts NO
Auxiliary
contacts NC
Control voltage
L
3 = 3-pole
4 = 4-pole NO
B = 4-pole 2NO + 2NC
T = screw terminal
M = double clamp
terminal
Contactors Series CK
Type
identification
C
A=AC
E=DC/AC with electronic module
Housing
07 10
75 11
08 12
85 13
09
95
Auxiliary
contacts NO
Auxiliary
contacts NC
Control voltage
K
Version
(B, C)
3 = 3-pole
4 = 4-pole (4NO)
Thermal overload relay RT
Type
identification
R
Setting range (A...W)
T
Housing
2
= class 10A (RT1)
class 10 (RT2, RT3, RT4, RT5, RT6)
= class 20 (RT1. RT2. RT3)
L
= class 30
–
(RT4, RT5, RT6)
K
5
SERIES CK - Contactors
Three- and four-pole
contactors
– Control circuit:
Alternating current up to 690V
Direct current up to 500V
– Power circuit up to 1000V AC
– Degree of protection: IP00
– CK07...CK13: auxiliary and coil terminals
originally protected against accidental contacts.
Protection for power contacts on request
(see accessories).
– CK...E with electronic module suitable for DC
and AC (50/60 Hz)
CK08CA...
CK09BE...
Three-pole contactors from 150 to 825A (AC3)
Maximum operating
current
Noninductive
load
Admissible power
AC3
Electrical Control Aux.
endurance circuit cont
AC1
Motors
220V 380V 415V 440V 500V
≤ 440V, 230V 400V
3-phase
50/60 Hz
AC3
AC3
A
A
kW
kW kW
kW
kW
250
150
45
75
80
100 1.7 x 106
80
•4 •2
# ops.
100 100 110 1.2 x 106
185
55
90
315
205
65
110 125 125 132 1.7 x 106
315
450
600
700
1000
1250
250
309
420
550
700
825
75
90
125
160
220
250
132
160
220
280
375
450
132
185
230
315
425
450
160
200
300
400
480
500
Pack Weight
• 3 •1
250
132
160
230
315
400
450
Cat. no.(1)
1.5 x 106
1.1 x 106
1 x 106
0.8 x 106
0.7 x 106
0.7 x 106
AC/DC(2)
AC/DC(3)
AC/DC(2)
AC/DC(3)
AC/DC(2)
AC/DC(3)
AC/DC(3)
AC/DC(3)
AC/DC(3)
AC/DC(3)
AC/DC(3)
AC/DC(2)
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
CK75CA311
CK75CE311
CK08CA311
CK08CE311
CK85BA311
CK85BE311
CK09BE311
CK95BE311
CK10CE311
CK11CE311
CK12BE311
CK13BA311
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
1
1
1
1
1
1
1
1
1
1
1
1
3.4
3.5
3.4
3.5
5.9
6.1
6.2
6.3
11
11
18
35
Four-pole contactors from 200 to 1250A (AC1)
Electrical Control Aux. Cat. no.(1)
endurance circuit cont.
Max. oper. Admissible power
current
AC3
AC1
Noninductive
load
AC1
380V
400V
220V 380V 415V 440V 500V
230V 400V
A
kW
A
200
55
105 76
(2) (3)
• 3 •1
•4 •2
AC1
kW
kW
kW
kW
kW # ops.
131 143 151 173 1 x 106
CK12BE...
325
100 185 123 214 233 247 281 0.6 x 106
400
500
600
700
1000
1250
132
160
220
280
375
450
250
309
408
530
680
800
152
191
228
266
381
476
263
329
395
460
658
822
287
359
431
503
719
898
304
380
456
533
762
952
Pack Weight
346
415
519
606
866
1082
0.6 x 106
0.6 x 106
0.5 x 106
0.4 x 106
0.4 x 106
0.6 x 106
AC/DC(2)
AC/DC(3)
AC /DC(2)
AC/DC(3)
AC/DC(3)
AC/DC(3)
AC/DC(3)
AC/DC(3)
AC/DC(3)
AC/DC(2)
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
CK07BA411
CK07BE411
CK08BA411
CK08BE411
CK09BE411
CK95BE411
CK10CE411
CK11CE411
CK12BE411
CK13BA411
CK13BA...
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
1
1
1
1
1
1
1
1
1
1
4.7
4.8
14.8
14.9
15.1
15.3
22.3
22.8
23.3
44
Available coil voltages
Alternating current (V). For contactors types CK75CA... to CK85BA...
◆
C
50 Hz
60 Hz
D
24
24
F
42
48
G
48
H
I
J
K
110 127
110 120
M
N
R
S
T
U
V W X
Y
Z
220 240
380
415 440 500 660
230
400
690
220 277
240 380
480 440
600
Alternating current / direct current with
electronic module (V). (for types CK...E)
(0.80 ... 1.10 x Us)
Direct current with electronic module.
For types CK75CE... and CK08CE...
(0.70 ... 1.30 x Us) (4)
◆
◆
50/60 Hz
D
24
28
F
J
N
U
Y
42 110 220 380 440
48 127 250 415 500
Voltage
WD WE WF WH WJ WN
24 33 48 72 110 220
Alternating current (V). For contactors
type CK13BA...
Spare coils, see K.20
Thermal overload relays, see K.23
Technical specifications, see K.47
Dimensions, see K.53
(1) To complete the catalogue number, replace the
symbol ◆ by the corresponding code.
(2) CK...A only for AC control.
(3) CK...E with electronic module: AC (50/60 Hz)
and DC control.
(4) Maximum number of auxiliary contacts : four
◆
50 Hz
60 HZ
J
N
U
110 220 380
240 440
SERIES CK - Accessories
BCLL
Side mounted auxiliary contact blocks
–
–
–
–
Terminals protected against accidental contacts in accordance with VDE 0106 T.100, VBG4: IP2x.
Terminal numbering in accordance with EN 50005
CK-contactors always provided with one auxiliary contact block 1 NO + 1 NC
Up to four side mounted auxiliary contact blocks and combinations (2 on the left + 2 on the right) for
max. eight contacts.
Mounting
Aux. contacts
•3
•4
Side (left or right)
Side, combinations of
more than 2 blocks
K/RC-24
2
1
2
1
Cat. no.
Pack Weight
•1
•2
0
1
0
1
BCLL20
BCLL11
BRLL20
BRLL11
10
10
10
10
0.048
0.048
0.048
0.048
Transient voltage suppressor
Directly connected parallel to the coil terminals A1-A2
For use with
CK75...CK08...
CK 85...CK13...
BEKVA
Ue
24V-48V AC
50V - 127V AC
130V - 240V AC
227V - 500V AC
24V AC
260V AC
415V AC
Cat. no.
Pack Weight
BSLR3G
10 0.020
BSLR3K
10 0.020
BSLR3R
10 0.020
BSLV3U
10 0.050
K/RC-24
10 0.050
K/RC-48/260
10 0.050
K/RC-380/415 10 0.050
Mounting
Horizontal
Vertical
Vertical
Vertical
Cat. no.
BEKH
BEKVS
BEKVA
BEKV
Pack Weight
Cat. no. (1)
CM1CA5F
C09476
C09479
Pack Weight
Mechanical interlock
For use with
CK07B...CK12...
CK07B...CK95...
CK10C...CK12B...
CK13...
1
1
1
1
0.350
0.800
0.900
1.200
Pole terminal protection IPxxB
For use with
CK75C... – CK08C...
CK85B.3. – CK12B.3.
CK85B.4. – CK12B.4.
(1) Under development
Mounting
Single pole VDE0106
Single pole VDE0106
Single pole VDE0106
1
6
8
0.150
0.250
0.300
SERIES CK - Accessories
Alternating current without electronic module
Coils
KB5E◆
+ KM5E◆
CK...A
For use with
CK75CA3...CK08CA3...
CK85BA3...CK07BA4...
CK08BA4...
CK13BA3...CK13BA4...
Cat. no.(1) Pack Weight
C12168 ◆
1 0.415
1 0.450
C04255 ◆
1 1.540
C04787 ◆
1 1.200
C08998 ◆
Available coil voltages (V)
◆
C
D F G
24 42 48
24
48
50 Hz
60 Hz
H
I
J K M N S T
110 127
220
230
110 120
220 277 240 380
U V W X Y Z
380
415 450 550 660
400
690
480 440
600
Control circuit with incorporated rectifier bridge
CK...A
For use with
CK13BA3...CK13BA4...
Cat. no.(1) Pack Weight
C09120 ◆ 1 0.800
Available coil voltages (V)
◆
50 Hz
60 Hz
J N U
110 220 380
230 400
120 240 480
Direct current or alternating current 50/60 Hz, with electronic module
CK...E
Coil
Electronic
module
For use with
CK75CE3...CK08CE3...
CK85BE3...CK09BE3...CK95BE3...
CK07BE4...
CK12BE3...
CK08BE4...CK09BE4...CK95BE4...CK12BE4...
Cat. no.(1) Pack Weight
KB4E ◆
1 0.415
1 0.470
KB5E ◆
KB6E ◆
1
0.470
CK10CE3...CK11CE3...
CK10CE4...CK11CE4...
CK75CE3...CK08CE3...
CK85BE3...CK09BE3...CK95BE3...
CK07BE4...
CK12BE3...
CK08BE4...CK09BE4...CK95BE4...CK12BE4...
KB7E ◆
1
0.470
KM4E ◆
KM5E ◆
1
1
0.140
0.140
KM6E ◆
1
0.140
CK10CE3...CK11CE3...
CK10CE4...CK11CE4...
KM7E ◆
1
0.140
Available coil voltages (V) AC/DC
◆
Voltage
Contact kits
V1107BA
D F J N U Y
24 42 110 220 380 440
28 48 127 250 415 500
For use with
CK07B...
CK75C...
CK08C...
CK08B...(4 pole)
CK85B...
CK09B...
CK09B...(4 pole)
CK95B...
CK10C...
CK11C...
CK12B...
CK13B...
Number of sets
1
1
1
1
1
1
1
1
1
1
1
1
(1)To complete the catalogue number, replace the symbol ◆ by the code
corresponding to the
voltage and frequency of
the control circuit.
Type
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
Cat. no. (2)
V1107BA
V1175CA
V1108CA
V1108B4
V1185BA
V1109BA
V1109B4
V1195BA
V1110CE
V1111CE
V1112BA
V1113BA
Pack Weight
1
1
1
1
1
1
1
1
1
1
1
1
0.144
0.160
0.160
0.160
0.360
0.360
0.360
0.400
0.650
0.650
1.400
2.500
(2)One set consists of two fixed
contacts, one moving con
tact and accessory parts.
When contact replacement
is needed, it is recommended to replace all the
contacts at the same time.
SERIES CK - Technical data
General
Conformity to standards
IEC 947-1
CENELEC HD 419
CEI EN 60947-4-1
UL 508
EN 50005
IEC 947-4-1
NF C 63-110
ASE 1025
CSA 22.2/14
UNE 20109
Terminal capacity and tightening torque
BS 5424 & 775
NEMA ICS 1
VDE 0660/102
Approvals
UL
CSA
RINA
NOM
FI
Lloyds’ Register of Shipping
Bureau Veritas
Solid
Finely stranded with
end sleeve
Finely stranded without
end sleeve
Stranded
AWG wires
Tightening torque
CK07B
(mm2) 1.5...95
(mm2) 2...35
(mm2) 2...50
(mm2) 1.5...95
(mm2) 16...00
8 Nm
70 Lb x in
Ambient conditions
Storage temperature
Operation temperature
Operating altitude up to 3,000 m
Operating altitude from 3,000 to 4,000 m
Operating altitude from 4,000 to 5,000 m
– 55°C to + 80°C
– 40°C to + 60°C
Nominal values
90 % Ie 80 % Ue
80 % Ie 75 % Ue
CK07B
Climatic resistance IEC 68-2
Continuous tests
Cold
– Temperature
– Time
Dry heat
– Temperature
– Relative humidity
– Time
Humid heat
– Temperature
– Relative humidity
– Time
40/125/56 Cyclical tests
First half-cycle
– 40°C – Low temperature
+ 25°C
72 h – Relative humidity
93 %
– Time
12 h
+ 125°C Second half-cycle
≤ 50 % – Low temperature
+ 55 %
96 h – Relative humidity
95 %
– Time
12 h
+ 40°C Number of consecutive cycles
6
95 %
56 days
Mounting positions
Finely stranded with
end sleeve
AWG wires with
end sleeve
Busbars
Tightening torque
Finely stranded with
end sleeve
AWG wires with
end sleeve
Busbars
Tightening torque
With the same pick-up
and drop-out voltages
With the same rated power
CK75C to CK13B
(mm2)
(mm2)
(Nm)
(Lb x in)
CK75C
CK08C
1 x 120
2 x 95
1 x 300
2 x 107
2 (25 x 5)
8
70
CK11C
(mm2) 2 x 240
(mm2) 2 x 500
2 (35 x 10)
(Nm) 31.5
(Lb x in) 275
CK08B to CK10C
CK95B
1 x 240
2 x 185
2 x 150
1 x 500
2 x 350
2 x 300
2 (25 x 5) 2 (35 x 10)
23
31.5
200
275
CK12B
–
CK13B
–
–
2 (35 x 10)
31.5
275
–
2 (60 x 10)
31.5
275
SERIES CK - Technical data
Power circuit
Three-pole contactors
Rated thermal current Ith at θ ≤ 40°C
Rated operational current Ie AC3
Rated operational voltage Ue
Rated insulation voltage Ui
Maximum continuous current AC1
Frequency limits
Making capacity (RMS)
Breaking capacity (RMS)
Ue ≤ 400V
Ue = 500V
Ue = 690V
Ue = 1000V
Short-time current
1 sec.
5 sec.
10 sec.
30 sec.
1 min.
3 min.
Recovery time
Short-circuit protection with fuse
Coordination type "2"
aM
gl-gG
Impedance per pole
Power dissipation per pole
AC1
AC3
Insulation resistance
Between adjacent poles
Between poles and earth
Between input and output
CK75C
250
150
1000
1000
250
25...400
1850
CK08C
250
185
1000
1000
250
25...40
1850
CK85B
315
205
1000
1000
315
25...400
2500
CK09B
315
250
1000
1000
315
25...400
2500
CK95B
450
309
1000
1000
450
25...400
3700
CK10C
600
420
1000
1000
600
25...400
6500
CK11C
700
550
1000
1000
700
25...400
6500
CK12B
1000
700
1000
1000
1000
25...400
8400
CK13B
1250
825
1000
1000
1250
25...400
8250
(A)
(A)
(A)
(A)
1600
1600
1000
350
1600
1600
1000
350
2000
2000
1660
850
3500
3500
2200
1100
3500
3500
2200
1100
5600
5600
3500
2000
5600
5600
3500
2000
7300
7000
6700
3500
6600
6600
6000
3500
(A)
(A)
(A)
(A)
(A)
(A)
(min.)
2500
2500
2300
1250
900
600
10
2500
2500
2300
1250
900
600
10
4000
3200
2400
1400
1000
750
10
5500
3500
2500
1600
1200
900
10
5500
3500
2500
1600
1200
900
10
7500
5200
4000
2800
1800
1200
10
7500
5200
4000
2800
1800
1200
10
9700
7700
6100
4400
3500
2300
10
11600
8800
7350
5300
4500
2800
10
(A)
(A)
(mΩ)
160
250
0.30
200
250
0.30
250
315
0.28
250
400
0.28
315
500
0.28
400
630
0.15
500
800
0.13
630
1000
0.14
1000
1250
0.11
19
6.8
19
10.3
27.7
11.7
27.7
17.5
56.7
26.7
54.3
26.5
63.7
45.3
140
68.6
171.8
74.8
> 10
> 10
> 10
> 10
> 10
> 10
> 10
> 10
> 10
> 10
> 10
> 10
> 10
> 10
> 10
> 10
> 10
> 10
> 10
> 10
> 10
> 10
> 10
> 10
> 10
> 10
> 10
(A)
(A)
(V)
(V)
(A)
(Hz)
(A)
(W)
(W)
(MΩ)
(MΩ)
(MΩ)
Four-pole contactors
Rated thermal current Ith at θ ≤ 40°C
Rated operational voltage Ue
Rated insulation voltage Ui
Maximum continuous current AC1
Frquency limits
Making capacity (RMS)
Breaking capacity (RMS)
Ue ≤ 400V
Ue = 500V
Ue = 690V
Ue = 1000V
Short-time current
1 sec.
5 sec.
10 sec.
30 sec.
1 min.
3 min.
Recovery time
Short-circuit protection with fuse
Coordination type "2"
gL-gG
Impedance per pole
Power dissipation per pole
AC1
Insulation resistance
Between adjacent poles
Between poles and earth
Between input and output
CK07B
200
690
1000
200
25...400
1150
CK08B
325
1000
1000
325
25...4000
1850
CK09B
400
1000
1000
400
25...400
2500
CK95B
500
1000
1000
500
25...400
3700
CK10C
600
1000
1000
600
25...400
6500
CK11C
700
1000
1000
700
25...400
6500
CK12B
1000
1000
1000
1000
25...400
6700
CK13B
1250
1000
1000
1250
25...400
8250
950
950
800
–
1600
1600
1000
350
3500
3500
2200
1100
3500
3500
2200
1100
5600
5600
5000
300
5600
5600
5000
300
6700
6700
6000
3500
6600
6600
6000
3500
(A)
(A)
(A)
(A)
(A)
(A)
(min.)
2100
1500
1150
750
550
350
10
2500
2500
2300
1250
900
600
10
5500
3500
2500
1600
1200
900
10
5500
3500
2500
1600
1200
800
10
7500
5200
4000
2800
1800
1200
10
7500
5200
4000
2800
1800
1200
10
9700
7700
6100
4400
3500
2300
10
11600
8800
7350
5300
4500
2800
10
(A)
(mΩ)
250
0.45
400
0.32
500
0.28
500
0.28
630
0.15
800
0.13
1000
0.14
1250
0.11
18
33.8
44.8
56.7
61.2
68.6
140
171.8
> 10
> 10
> 10
> 10
> 10
> 10
> 10
> 10
> 10
> 10
> 10
> 10
> 10
> 10
> 10
> 10
> 10
> 10
> 10
> 10
> 10
> 10
> 10
> 10
(A)
(V)
(V)
(A)
(Hz)
(A)
(A)
(A)
(A)
(A)
(W)
(MΩ)
(MΩ)
(MΩ)
SERIES CK - Technical data
Control circuit
Three-pole contactors
Alternating current
Rated insulation voltage Ui
(V)
Standard voltages Us (50/60 Hz)
(V)
Operating limits
Switch-on
xUs
Switch-off
xUs
Consumption
Seal
(VA)
Pick-up
(VA)
Power dissipation
(W)
Power factor
Seal
(cos ϕ)
Pick-up
(cos ϕ)
Opening and closing times at Us
Making time at excitation (NO contacts) (ms)
Breaking time at desexcitation (NO contacts) (ms)
Mechanical endurance
106 ops.
Maximum rate
No load
ops./h
AC1/AC3 at rated power
ops./h
AC2 at rated power
ops./h
AC4 at rated power
ops./h
Direct current
Rated insulation voltage Ui
(V)
Standard voltages Us (50/60 Hz)
(V)
Operating limits
Operating
xUs
Drop-out
xUs
Consumption
Seal
(W)
Pick-up
(W)
Opening and closing times at Us
Making time at excitation (NO contacts)
(ms)
Breaking time at desexcitation (NO contacts) (ms)
Mechanical endurance
106 ops.
Maximum rate
No load
ops./h
AC3 at rated power
ops./h
AC4 at rated power
ops./h
CK75C
1000
24...690
CK08C
1000
24...690
CK85B
1000
24...690
CK09B
1000
24...690
CK95B
1000
24...690
CK10C
1000
24...690
CK11C
1000
24...690
CK12B
1000
24...690
CK13B
1000
24...440
0.8...1.1
0.5...0.6
0.8...1.1
0.5...0.6
0.8...1.1
0.5...0.6
0.8...1.1
0.4...0.6
0.8...1.1
0.4...0.6
0.8...1.1
0.4...0.6
0.8...1.1
0.4...0.6
0.8...1.1
0.4...0.6
0.8...1.1
0.2...0.4
32
400
13
32
400
13
60
830
22.2
60
830
3.5
13
340
3.5
23
680
4
23
680
4
25
750
4.5
6
2760
6
0.4
0.6
0.4
0.6
0.37
0.6
-
-
-
-
-
approx. 1
approx. 1
20...25
10...13
10
20...25
10...13
10
36...40
10...15
10
60...70
13...17
10
60...70
13...17
10
80...90
40...50
10
80...90
40...50
10
70...80
70...80
10
50...55
115...130
3
2400
600
250
150
2400
600
250
150
2400
600
250
150
1200
600
250
150
1200
600
250
150
900
300
200
120
900
300
200
120
900
300
200
120
600
120
120
120
CK75C
1000
24...500
CK08C
1000
24...500
CK85B
1000
24...500
CK09B
1000
24...500
CK95B
1000
24...500
CK10C
1000
24...500
CK11C
1000
24...500
CK12B
1000
24...500
0.75...1.1 0.75...1.1 0.75...1.1 0.8...1.1
0.35...0.5 0.35...0.5 0.35...0.5 0.4...0.6
0.8...1.1
0.4...0.6
0.8...1.1
0.4...0.6
0.8...1.1
0.4...0.6
0.8...1.1
0.4...0.6
2
135
2
135
3.5
350
3.5
350
3.5
350
4
600
4
600
4.5
650
60...70
13...17
10
60...70
13...17
10
60...70
13...17
10
60...70
13...17
10
60...70
13...17
10
80...90
40...50
10
80...90
40...50
10
70...80
40...50
10
1200
600
150
1200
600
150
1200
600
150
1200
600
150
1200
600
150
900
300
120
900
300
120
900
300
120
SERIES CK - Technical data
Four-pole contactors
Alternating current
Rated insulation voltage Ui
(V)
Standard voltages Us (50/60 Hz)
(V)
Operating limits
Switch-on
xUs
Switch-off
xUs
Consumption
Seal
(VA)
Pick-up
(VA)
Power dissipation
(W)
Power factor
Seal
(cos ϕ)
Pick-up
(cos ϕ)
Opening and closing times at Us
Making time at excitation (NO contacts) (ms)
Breaking time at desexcitation (NO contacts) (ms)
Mechanical endurance
106 ops.
Maximum rate
No load
ops./h
AC1/AC3 at rated power
ops./h
Direct current
Rated insulation voltage Ui
(V)
Standard voltages Us
(V)
Operating limits
Switch-on
xUs
Switch-off
xUs
Consumption
Seal
(W)
Pick-up
(W)
Opening and closing times at Us
Making time at excitation (NO contacts) (ms)
Breaking time at desexcitation (NO contacts) (ms)
Mechanical endurance
106 ops.
Maximum rate
No load
ops./h
AC3 at rated power
ops./h
CK07B
1000
24...690
CK08B
1000
24...690
CK09B
1000
24...690
CK95B
1000
24...690
CK10C
1000
24...690
CK11C
1000
24...690
CK12B
1000
24...690
CK13B
1000
110...440
0.8...1.1
0.5...0.6
0.8...1.1
0.5...0.6
0.8...1.1
0.4...0.6
0.8...1.1
0.4...0.6
0.8...1.1
0.4...0.6
0.8...1.1
0.4...0.6
0.8...1.1
0.4...0.6
0.8...1.1
0.2...0.6
60
830
22.2
130
2860
18
25
750
4.5
25
750
4.5
25
750
4.5
23
680
4
25
750
4.5
25
2760
6
0.37
0.6
0.37
0.6
-
-
-
-
-
approx. 1
approx. 1
36...40
10...15
10
60...70
13...17
10
70...80
70...80
10
70...80
70...80
10
110...115 80...90
70...80
40...50
10
10
110...115 50...55
70...80
70...80
10
3
2400
600
900
600
900
600
900
600
900
300
900
300
900
300
CK07B
1000
24...500
CK08B
1000
24...500
CK09B
1000
24...500
CK95B
1000
24...500
CK10C
1000
24...500
CK11C
1000
24...500
CK12B
1000
24...500
0.75...1.1 0.8...1.1
0.35...0.5 0.4...0.6
0.8...1.1
0.4...0.6
0.8...1.1
0.4...0.6
0.8...1.1
0.4...0.6
0.8...1.1
0.4...0.6
0.8...1.1
0.4...0.6
3.5
350
4.5
650
4.5
650
4.5
650
4.5
650
4.5
650
4.5
650
60...70
13...17
10
70...80
70...80
10
70...80
70...80
10
70...80
70...80
10
80...90
40...50
10
80...90
40...50
10
110...115
70...80
10
1200
600
900
600
900
600
900
600
900
600
900
300
900
300
600
120
SERIES CK - Dimensional drawings
Three-pole contactors
CK75C
CK08C
CK85B
CK09B
CK95B
CK10C
CK11C
CK12B
CK13B
SERIES CK - Dimensional drawings
Four-pole contactors
CK07B
CK08B
CK09B
CK95B
CK10C
CK11C
CK12B
CK13
Mechanical interlock
BEKH
BEKV
A
BEKVS 550
BEKVA 350
A