PATIO POOL/ MECH F4,B3,W2 POOL VEST. 5 OS MEN F2,B2,W1,W3 ELEV. LOBBY F1,B1,W2 520 SQ. FT. BAG STOR. PANTRY J ENG./ MAINT J 3 JACUZZI 81 S.F. OS GREAT ROOM J ELEC. Da Db Dc LV BREAKFAST GUEST LAUNDRY F2,B2,W1 Dd 2 OS 11 ELEC F1,B1,W1 8 9 1/11/2016 10 3 J l J OS OS MARKET STOR. OS FITNESS F1,B3,W1 11 ELEV. #1 OS STORAGE J 3 LV POOL 450 S.F. ELEV. #2 J De J WOMEN F2,B2,W1,W3 J MEETING 345 S.F. MECH. / FIRE f OS g J 7 FITNESS VEST. LV 1 SALES Dm 4 MARKET F2,B4,W1 STAIR #1 F1,F3,B3,W1 OS LV LAUNDRY KING F1,B1,W1 ADA KING F1,B1,W1 KING F1,B1,W1 #124 #122 #120 BUSINESS CENTER k 672 S.F. ADA KING F1,B1,W1 J KING F1,B1,W1 h,Dj J WORK AREA STAIR #2 F1,F3,B3,W1 LV CONF. ROOM F1,B3,W1 OS 11 Inn Code ROWMH, Location # 17987 MILITARY HEIGHTS DRIVE ROSWELL, NM 88201 LOBBY OS SERVER #116 #118 CONF. STOR. 128 S.F. LV GEN. MNGR. 12 BREAK AREA CHECK-IN 6 VESTIBULE F2,B2,W1 A. MULTIPLE GROUPINGS OF DEVICES SHALL BE GANGED UNDER THE SAME COVERPLATE. SEPARATE PLATES ARE UNACCEPTABLE EXCEPT IN CASES OF DIMMER SWITCHES ADJACENT TO OTHER LIGHT SWITCHES. IN THAT CASE, PLATES SHALL BE AS CLOSE TOGETHER AS POSSIBLE, PLUMB TRUE FOR A NEAT AND COMPACT ORGANIZED APPEARANCE. B. CONTRACTOR SHALL PROVIDE ADDITIONAL UNSWITCHED PHASE CONDUCTORS FOR LIGHTING NOT CONTROLLED BY LIGHTING CONTROL PANEL. C. REFER TO SHEETS 'E-704' AND 'E-705' FOR LIGHT FIXTURE SCHEDULE. D. REFER TO SHEET 'E-706' FOR LIGHTING CONTROL PANEL SCHEDULE. 9. PHOTO SENSOR. LOCATE ON ROOF DIRECTLY ABOVE ELECTRICAL ROOM, FACE NORTH AND AVOID PLACING NEAR OR AIMING TOWARDS LUMINAIRES. PROVIDE MOUNTING MEANS. * This document (whether in hard copy or electronic file formats) is the property of Design 2 Function, LLC and is part of our instruments of service. The information contained in this drawing shall not be used for any purpose other than for the construction of the referenced project. Any other use, reuse or modification of the prints or electronic files without our prior written consent is expressly prohibited and, if done so, will be at the recipient's sole risk and without liability or legal exposure to Design 2 Function. * Due to variation in printing techniques, only printed dimension shall be used. Contractor(s) shall verify all layouts, dimensions and other related information prior to bidding or construction. 10. INTERLOCK PHOTO SENSOR WITH 'LCP'. DRAWING ISSUE DATES: 12/14/15 - 100% REVIEW SET 1/11/16 - BID / PERMIT SET 11. 4-BUTTON FADER STATION. 12. LOW VOLTAGE WALL SWITCH, WALL OCCUPANCY SENSOR, CEILING OCCUPANCY SENSOR AND POWER PACK SIMILAR TO 'DOUGLAS LIGHTING CONTROLS - DIVERSA SERIES', TYPICAL. PROJECT MANAGER: NICK PIRKL DRAWN BY: JEFF LOPEZ SHEET TITLE: 1 LIGHTING PLAN FIRST FLOOR Scale: 1/8" = 1'-0" Engineers Planners Construction Services 0 2 4 1/8" = 1'-0" 8 16 24 8102 Menaul Blvd. NE, Suite D, Albuquerque, NM 87110 tele: 505.255.7802 PROJECT #15-047 www.abqeng.com LIGHTING PLAN FIRST FLOOR E-107 SHEET: 110 OF 127