materials specification

advertisement

MATERIALS SPECIFICATION

Lanko Grout 180 ECO

(1) MATERIALS

A. Acceptable Manufacturer

ParexGroup Pte Ltd

28, Tuas South Ave 8, Singapore 637648

Tel: 65 68610632

Fax: 65 68623915

Email: sales@parexgroup.com.sg

B. Proprietary Products

The non shrink grout to be used shall be Lanko Grout 180 ECO – a cementitious non shrink grout which is specially formulated to have a lower embodied carbon foot print.

C. Rate of Application

General:

Yield per bag :

Approx. 0.013m

3

1

(2) EXAMINATION

A.

B.

Site Visit:

Prior to installation, arrange visit to project site with the authorized representative to inspect and certify that concrete surfaces are in acceptable condition.

Verification of Substrates:

Verify that concrete surfaces are sound and clean. Ensure that concrete surface has not been treated with wax based curing compounds and does not have residues from formwork release agents left on the surface as they can cause loss of adhesion. Steel trowel finished concrete must be wire brushed prior to tiling

(3) MIXING & APPLICATION

Surface Preparation

All surfaces must be cleaned and free of oil, dust, paint, curing compound etc. Thoroughly damp all surfaces before starting and keep in a moist condition during placing.

Mixing

Damp the grout mixer with water prior to mixing the initial batch of Lanko Grout 180 ECO.

Ensure that the mixer is free of standing water. Add the pre-measured quantity of water. Slowly add the Lanko Grout 180 ECO, mixing continuously for at least 3 to 5 minutes until a homogeneous consistent grout is achieved.

Water Required

Application

Underplate:

4.5 – 5 litres/ bag for flowable consistency

3.0-3.2 litres/bag for pasty consistency

Check that the formwork is sealed against grout leakage and that a minimum hydrostatic head of

100mm can be maintained. Ensure sufficient material is available to complete the work and obtain a continuous fill. Pour from one side only to avoid air entrapment, keeping a head on the grout to promote flow.

Do not vibrate, but rods, straps and chains can be used to aid complete filling.

Preplaced Aggregate Grout:

Grout should be pumped or poured into place. Compressive strength development and ultimate strength of the concrete are reduced slightly compared with flowing grouts.

2

Grouting Large Volumes:

For grouting thickness greater than 75mm, the addition of clean well-graded 10mm aggregates is recommended to reduce temperature rise. Use a maximum of one part aggregate to 2.5 part of grout by weight. Conventional concrete pan mixers and pumps can be used for mixing and placement.

Curing

Immediately after finishing, exposed area are should be thoroughly cured with water or curing compound.

(4) MATERIAL TECHNICAL PERFORMANCE

LANKO Grout 180 ECO or equivalent

Appearance Grey Powder

Consistency

Filler

Shrinkage

Fluid or flowing

Graded Sand

No shrinkage

>40 N/mm 2 Compressive Strength

ASTM C939

ASTM C940

ASTM C942

Setting Time Initial: approx. 5-8hours

Final: approx. 6-9 hours

ASTM C953

Specifications and results stated above are typical but reflect test procedures used.

Actual field performance will depend on installation method and site conditions.

(5) CLEANING AND PROTECTION

Cleaning:

Clean spillage and soiling from adjacent surfaces using appropriate cleaning agents and procedures.

Protection:

Take measures to protect completed area. Do not permit traffic for at least 1 day.

3

(6) WARRANTY

Manufacturer’s Warranty:

Manufacturer shall provide standard product warranty executed by authorized company official. Term of warranty shall be [specify term] years from the Date of Substantial

Completion.

Applicator’s Warranty:

Applicator shall warrant the tile installation against defects caused by faulty workmanship or materials for a period [specify term] years from the Date of Substantial

Completion. The warranty will cover the surfaces treated and will bind the applicator to repair, at the expense of the applicator, any and all leaks through the treated surfaces which are not due to structural weakness or other causes beyond applicator’s control such as fire, earthquake, tornado and hurricane. The warranty shall read as follows:

Warranty: The applicator warrants that, upon the completion of work, surfaces tiled with

Lanko Grout 180 ECO will be and will remain free from any defect, due workmanship or materials for a period of [specify term] years from Date of Substantial Completion. In the event of any defects occurring within the warranty period from such causes, the applicator shall, at his sole expense, repair, replace or otherwise correct such defective workmanship or materials. Applicator shall not be liable for consequential damages and applicator’s liability shall be limited to repair, replacement or corrected of defective workmanship or materials. Applicator shall have no responsibility with respect to defects caused by structural failure or movement of the structure, or any other causes beyond the applicator’s control.

4