EB-50GU-A STANDARD PACKAGE
• EB-50GU-A Centralized Controller
•
•
PAC-SC51KUA Power Supply
Monitoring Annual and Weekly Scheduling,
Sending Error Email, Online Maintenance Tool,
Interlock Control and Data Monitoring
OPTIONAL SOFTWARE
• SW-Charge: Tenant Billing
- Calculates per tenant CITY MULTI® energy usage based
on the refrigerant capacity used of the outdoor unit(s) divided
among the associated indoor units
- Requires TG-2000 software Ver. 6.40 or later installed on a
dedicated, networked PC connected to a RS-485 watt hour
meter (WHM)
• SW-PWeb: Online Personal Browser
- Allows individual users (up to 50) to control their respective
zone conditions via personal networked PC with or without
local remote controllers installed in the space
EB-50GU-A CENTRALIZED CONTROLLER
SPECIFICATIONS
• Manages up to 50 Indoor Units individually, in a group or in a
collective batch operation
• Supports dual set point functionality
(connected model dependent)
• Displays:
- CITY MULTI® compressor speed and hi/low pressure
- Advanced HVAC Controller (DC-A2IO) input/output status
- Indoor unit free contact input/output status
- Space Temperature and Humidity
(from Smart ME or AI controller)
- Error code
- Unoccupied setback up temperature range
• Functions
- Hold function (temporarily disables schedules indoor unit model dependent)
- Initial setting
- Operation data back-up
• Permits or prohibits remote controller functions:
- On/Off
- Change Operation Mode
- Change Set point Temperature
- Filter Status
- Change Fan Speed
- Change Air Direction
Specifications are subject to change without notice.
© 2013 Mitsubishi Electric US, Inc.
Date:
• External input/output signals can be used for batch operations
such as Start/Stop and Emergency Stop
(Requires PAC-YG10HA)
• Temperature set point range limits can be set for local remote
controllers
• User defined indoor unit functions:
- On/Off
- Monitoring and Operation
- Operation mode:
○○Auto* (Dual or Single set point)
○○Cool
○○ Heat
○○ Fan
○○ Drying
○○Setback*
Note: *R2 Series only (connected equipment dependent)
-- Temperature Setting
-- Fan Speed
-- Airflow Direction
• Monitoring and Control:
- CITY MULTI® indoor units
- M & P Series units (Requires M-Net adapter)
- Lossnay units
- PWFY hydronic heat pump units
- DIDO controllers
- CITY MULTI® DOAS
- Interlock setting enables integration of general equipment inputs/outputs and indoor units
• Scheduling
- Daily
- Annually
- Five pattern weekly seasonal schedule
• Twenty four scheduled events per day, indoor unit model
dependent:
- ON/OFF
- Mode
- Temperature Setting
- Vane Direction
- Fan
- Speed
- Operation Prohibits
• Trend data:
- Fan operation time
- Thermo-on time
- Set temperature
- Room temperature
- AI Controller temperature and humidity
(Requires PAC-YG63 MCA, 2 inputs total for each controller)
EB-50GU-A - System Configuration
4. System configuration
Models:
The figure below only shows the transmission cable connections. Power cables are omitted.
Power (24 VDC)
Power supply unit
PAC-SC51KUA
(sold separately)
M-NET
outdoor unit (Y)
Indoor unit
Centralized controller
EB-50
[000]
AHC
Group 2
[004]
TB7
[005]
[001]
[002]
[003]
MA
BC controller
Group 3
[057]
TB3
[006]
ME
[007]
[11]
[009]
[010]
AHC [201]
Mr. Slim/M- and P-Series
outdoor unit
[12]
M-NET adapter
Group 4
MA
14
Specifications are subject to change without notice.
© 2013 Mitsubishi Electric US, Inc.
LOSSNAY
[008]
[106]
Mr. Slim/M- and P-Series
outdoor unit
MA
Numbers in the parentheses indicate
address numbers.
Group 1
MA
[056]
Advanced HVAC CONTROLLER
M-NET transmission cable
MA remote controller cable
TB3
M-NET
outdoor unit (R2)
Local remote controller
M-NET
[051]
TB7
LAN
Group 5
Fig. 4-1
Model:
EB-50GU-A - Specifications
EB-50GU-A Centralized Controller
Power Supply
Item
Environmental Conditions
Weight
Dimensions (W x H x D)
Controller Drive
Temperature
Humidity
Specifications
24VDC ± 5%
*Power Supply: PAC-SC51KUA
Operating Range
-10° C – +55° C [+14° F – +131° F]
Non-operating Range
-20° C – +60° C [-4° F – +140° F]
30-90% RH (No condensation)
2 lbs. (0.7 kg)
6-1/2 × 4-3/4 × 1-13/16 in. (165 × 120 × 46 mm)
Web Browser Requirements
Item
CPU
Memory
Screen Resolution
Compatible
Browser
Windows®
Macintosh
Onboard LAN Port or LAN Card
Other
Requirements
1 GHz or faster
512 MB or more
1024 x 768 or higher recommended
Microsoft® Internet Explorer 8.0
Microsoft® Internet Explorer 9.0
* Java execution environment is required.
(Oracle® Java Plug-in Ver. 1.7.0_11)
* Install Oracle® Java Plug-in that is appropriate for your operating system.
When using a 64-bit Internet Explorer, install a 64-bit Java Plug-in.
* The version of the Oracle® Java Plug-in can be verified by clicking [Java] in the Control Panel.
Safari 6
* Java execution environment is required.
(Oracle® Java Plug-in Ver. 1.7.0_11)
* The version of the Oracle® Java Plug-in can be verified by clicking [Help]-[Installed Plug-ins] on the Safari
browser.
One connector (100BASE-TX)
Pointing device such as a mouse.
Specifications are subject to change without notice.
© 2013 Mitsubishi Electric US, Inc.
Model:
EB-50GU-A - Dimensions
External dimension
Unit:mm[in.]
225 (8-7/8)
205 (8-3/32)
46 (1-13/16)
L-fitting
30 (1-3/16)
20 (13/16)
Notes:
Specifications are subject to change without notice.
© 2013 Mitsubishi Electric US, Inc.
36 (1-7/16)
20 (13/16)
4.5 (3/16)
10 (13/32)
4.5 (3/16)
120 (4-3/4)
50 (1-31/32)
60 (2-3/8)
20 (13/16)
165 (6-1/2)
Model:
PAC-SC51KUA
POWER SUPPLY (PAC-SC51KUA) SPECIFICATIONS
•
•
•
•
•
•
Rated input voltage and current: 100 - 240VAC ±10 %; 0.8A – 0.4A; 50Hz/60Hz single-phase.
Fuse: 6.3A time delay type.
Output voltage/current: M-NET: 23.0 – 32.0VDC; DC power supply: 24VDC ±5% 0 - 0.75A.
Dimensions: (H x W x D) 6-11/16 x 10-11/16 x 2-7/8”.
Weight: 3-1/8 lbs.
Indoor installation in field-supplied control panel or surface mount attachment (sold separately).
Item
Source Power Requirements
Output Voltage / Current
Load Capacity
Environmental Conditions
Dimensions (H x W x D)
Weight
Installation Environment
Specifications
Rated Input Voltage /
100 - 240VAC ±10%; 0.8A - 0.4A, 50/60Hz
Current
single phase
Fuse: 6.3 time delay type (IEC127-2 S.S.5)
M-NET
23.0 - 32.0VDC
DC Power Supply
24VDC ±5%; 0 - 0.75A
One EB-50GU-A Centralized Controller
Operating Range
14° - 131°F (-10° - +55°C)
Temperature
-4° - +140°F (-20° Storage Range
+60°C)
Humidity
30-90% RH (no condensation)
6-11/16 x 10-11/16 x 2-7/8" (169 x 271 x 72mm)
3-1/8 lbs. (1.4kg)
Indoor installation in field-supplied control panel or surface mount attachment
(sold separately).
PAC-SC51KUA POWER SUPPLY DIMENSIONS
169 (6-11/ 16)
155 (6-1/ 8)
72 (2-7/ 8)
130 (5-1/ 8)
271 (10-11/16)
90 (3-9/16)
T
TB2,TB3
TB1
1340 Satellite Boulevard
FORM# EB-50GU-A Standard Package - 201311
Specifications are subject to change without notice.
© 2013 Mitsubishi Electric US, Inc.
Suwanee, GA 30024
Tele: 678-376-2900 • Fax: 800-889-9904
Toll Free: 800-433-4822
www.mehvac.com
Download