Model: EB-50GU-A Standard Package Job Name: Schedule Reference: EB-50GU-A STANDARD PACKAGE • EB-50GU-A Centralized Controller • • PAC-SC51KUA Power Supply Monitoring Annual and Weekly Scheduling, Sending Error Email, Online Maintenance Tool, Interlock Control and Data Monitoring OPTIONAL SOFTWARE • SW-Charge: Tenant Billing - Calculates per tenant CITY MULTI® energy usage based on the refrigerant capacity used of the outdoor unit(s) divided among the associated indoor units - Requires TG-2000 software Ver. 6.40 or later installed on a dedicated, networked PC connected to a RS-485 watt hour meter (WHM) • SW-PWeb: Online Personal Browser - Allows individual users (up to 50) to control their respective zone conditions via personal networked PC with or without local remote controllers installed in the space EB-50GU-A CENTRALIZED CONTROLLER SPECIFICATIONS • Manages up to 50 Indoor Units individually, in a group or in a collective batch operation • Supports dual set point functionality (connected model dependent) • Displays: - CITY MULTI® compressor speed and hi/low pressure - Advanced HVAC Controller (DC-A2IO) input/output status - Indoor unit free contact input/output status - Space Temperature and Humidity (from Smart ME or AI controller) - Error code - Unoccupied setback up temperature range • Functions - Hold function (temporarily disables schedules indoor unit model dependent) - Initial setting - Operation data back-up • Permits or prohibits remote controller functions: - On/Off - Change Operation Mode - Change Set point Temperature - Filter Status - Change Fan Speed - Change Air Direction Specifications are subject to change without notice. © 2013 Mitsubishi Electric US, Inc. Date: • External input/output signals can be used for batch operations such as Start/Stop and Emergency Stop (Requires PAC-YG10HA) • Temperature set point range limits can be set for local remote controllers • User defined indoor unit functions: - On/Off - Monitoring and Operation - Operation mode: ○○Auto* (Dual or Single set point) ○○Cool ○○ Heat ○○ Fan ○○ Drying ○○Setback* Note: *R2 Series only (connected equipment dependent) -- Temperature Setting -- Fan Speed -- Airflow Direction • Monitoring and Control: - CITY MULTI® indoor units - M & P Series units (Requires M-Net adapter) - Lossnay units - PWFY hydronic heat pump units - DIDO controllers - CITY MULTI® DOAS - Interlock setting enables integration of general equipment inputs/outputs and indoor units • Scheduling - Daily - Annually - Five pattern weekly seasonal schedule • Twenty four scheduled events per day, indoor unit model dependent: - ON/OFF - Mode - Temperature Setting - Vane Direction - Fan - Speed - Operation Prohibits • Trend data: - Fan operation time - Thermo-on time - Set temperature - Room temperature - AI Controller temperature and humidity (Requires PAC-YG63 MCA, 2 inputs total for each controller) EB-50GU-A - System Configuration 4. System configuration Models: The figure below only shows the transmission cable connections. Power cables are omitted. Power (24 VDC) Power supply unit PAC-SC51KUA (sold separately) M-NET outdoor unit (Y) Indoor unit Centralized controller EB-50 [000] AHC Group 2 [004] TB7 [005] [001] [002] [003] MA BC controller Group 3 [057] TB3 [006] ME [007] [11] [009] [010] AHC [201] Mr. Slim/M- and P-Series outdoor unit [12] M-NET adapter Group 4 MA 14 Specifications are subject to change without notice. © 2013 Mitsubishi Electric US, Inc. LOSSNAY [008] [106] Mr. Slim/M- and P-Series outdoor unit MA Numbers in the parentheses indicate address numbers. Group 1 MA [056] Advanced HVAC CONTROLLER M-NET transmission cable MA remote controller cable TB3 M-NET outdoor unit (R2) Local remote controller M-NET [051] TB7 LAN Group 5 Fig. 4-1 Model: EB-50GU-A - Specifications EB-50GU-A Centralized Controller Power Supply Item Environmental Conditions Weight Dimensions (W x H x D) Controller Drive Temperature Humidity Specifications 24VDC ± 5% *Power Supply: PAC-SC51KUA Operating Range -10° C – +55° C [+14° F – +131° F] Non-operating Range -20° C – +60° C [-4° F – +140° F] 30-90% RH (No condensation) 2 lbs. (0.7 kg) 6-1/2 × 4-3/4 × 1-13/16 in. (165 × 120 × 46 mm) Web Browser Requirements Item CPU Memory Screen Resolution Compatible Browser Windows® Macintosh Onboard LAN Port or LAN Card Other Requirements 1 GHz or faster 512 MB or more 1024 x 768 or higher recommended Microsoft® Internet Explorer 8.0 Microsoft® Internet Explorer 9.0 * Java execution environment is required. (Oracle® Java Plug-in Ver. 1.7.0_11) * Install Oracle® Java Plug-in that is appropriate for your operating system. When using a 64-bit Internet Explorer, install a 64-bit Java Plug-in. * The version of the Oracle® Java Plug-in can be verified by clicking [Java] in the Control Panel. Safari 6 * Java execution environment is required. (Oracle® Java Plug-in Ver. 1.7.0_11) * The version of the Oracle® Java Plug-in can be verified by clicking [Help]-[Installed Plug-ins] on the Safari browser. One connector (100BASE-TX) Pointing device such as a mouse. Specifications are subject to change without notice. © 2013 Mitsubishi Electric US, Inc. Model: EB-50GU-A - Dimensions External dimension Unit:mm[in.] 225 (8-7/8) 205 (8-3/32) 46 (1-13/16) L-fitting 30 (1-3/16) 20 (13/16) Notes: Specifications are subject to change without notice. © 2013 Mitsubishi Electric US, Inc. 36 (1-7/16) 20 (13/16) 4.5 (3/16) 10 (13/32) 4.5 (3/16) 120 (4-3/4) 50 (1-31/32) 60 (2-3/8) 20 (13/16) 165 (6-1/2) Model: PAC-SC51KUA POWER SUPPLY (PAC-SC51KUA) SPECIFICATIONS • • • • • • Rated input voltage and current: 100 - 240VAC ±10 %; 0.8A – 0.4A; 50Hz/60Hz single-phase. Fuse: 6.3A time delay type. Output voltage/current: M-NET: 23.0 – 32.0VDC; DC power supply: 24VDC ±5% 0 - 0.75A. Dimensions: (H x W x D) 6-11/16 x 10-11/16 x 2-7/8”. Weight: 3-1/8 lbs. Indoor installation in field-supplied control panel or surface mount attachment (sold separately). Item Source Power Requirements Output Voltage / Current Load Capacity Environmental Conditions Dimensions (H x W x D) Weight Installation Environment Specifications Rated Input Voltage / 100 - 240VAC ±10%; 0.8A - 0.4A, 50/60Hz Current single phase Fuse: 6.3 time delay type (IEC127-2 S.S.5) M-NET 23.0 - 32.0VDC DC Power Supply 24VDC ±5%; 0 - 0.75A One EB-50GU-A Centralized Controller Operating Range 14° - 131°F (-10° - +55°C) Temperature -4° - +140°F (-20° Storage Range +60°C) Humidity 30-90% RH (no condensation) 6-11/16 x 10-11/16 x 2-7/8" (169 x 271 x 72mm) 3-1/8 lbs. (1.4kg) Indoor installation in field-supplied control panel or surface mount attachment (sold separately). PAC-SC51KUA POWER SUPPLY DIMENSIONS 169 (6-11/ 16) 155 (6-1/ 8) 72 (2-7/ 8) 130 (5-1/ 8) 271 (10-11/16) 90 (3-9/16) T TB2,TB3 TB1 1340 Satellite Boulevard FORM# EB-50GU-A Standard Package - 201311 Specifications are subject to change without notice. © 2013 Mitsubishi Electric US, Inc. Suwanee, GA 30024 Tele: 678-376-2900 • Fax: 800-889-9904 Toll Free: 800-433-4822 www.mehvac.com