Genesis WG4 High-Candela Speaker-Strobe Installation Sheet Number Description WG4WN-SVMHC Outdoor-rated wall/ceiling speaker-strobe (25/70 V), white without marking, 102/123/147/161 cd, clear lens [1] Only indoor strobes with a clear lens comply with the latest requirements of UL 1971 Signaling Devices for the Hearing Impaired. Table 2: Accessories Number Description WG4WTS [1] Outdoor-rated surface skirt, white - for Genesis WG4 speaker or speaker/strobe WG4RTS [1] Outdoor-rated surface skirt, red - for Genesis WG4 speaker or speaker/strobe WGRGSKT Appliance replacement gasket [1] The trim skirt is outdoor-rated when used with the 449 weatherproof box. Description The Genesis WG4 High-Candela Speaker-Strobe is a fire alarm and mass notification and emergency communication (MNEC) appliance designed for indoor or outdoor wet location use on ceilings or walls. See Table 1 below for a list of models and Table 2 for a list of accessories. Synchronized operation requires a separately installed synchronization control module. See Table 3 on page 3 for a list of compatible synchronization sources. Installation The speaker-strobe includes field-configurable switches for setting speaker and strobe output levels. The settings are visible after final installation. Install this appliance in accordance with the latest edition of NFPA 72 and the local authority having jurisdiction. Table 1: Models Number Description WG4RF-SVMHC Outdoor-rated wall/ceiling speaker-strobe (25/70 V), multi-tap, red with FIRE marking, 102/123/147/161 cd, clear lens WG4RN-SVMHC Outdoor-rated wall/ceiling speaker-strobe (25/70 V), multi-tap, red without marking, 102/123/147/161 cd, clear lens WARNING: Electrocution hazard. To avoid personal injury or death from electrocution, remove all sources of power and allow stored energy to discharge before installing or removing equipment. Caution: Electrical supervision requires the wire run to be broken at each terminal. Do not loop the signaling circuit field wires around the terminals. WG4WA-SVMHA [1] Outdoor-rated wall/ceiling speaker-clear-strobe (25/70 V), multi-tap, white with ALERT marking, 84/101/125/130 cd, Amber lens WG4WA-SVMHC Outdoor-rated wall/ceiling speaker-strobe (25/70 V), multi-tap, white with ALERT marking, 102/123/147/161 cd, clear lens WG4WF-SVMHC Outdoor-rated wall/ceiling speaker- strobe (25/70 V), multi-tap, white with FIRE marking, 102/123/147/161 cd, clear lens Note: The Genesis WG4 High-Candela Speaker-Strobe may be ceiling-mounted or wall-mounted and may be placed in one of four positions (strobe above, strobe below, and strobe to either side); place the electrical box accordingly. See Figure 4. To install the speaker-strobe: WG4WN-SVMHA [1] Outdoor-rated wall/ceiling speaker-strobe (25/70 V), multi-tap, white without marking, 84/101/125/130 cd, amber lens © 2011 UTC Fire & Security. All rights reserved. 1/4 1. Remove the cover from the speaker-strobe by first removing the six cover screws. See Figure 1 on page 2. 2. If desired, place the optional trim skirt over the electrical box. See “Specifications” for a list of compatible boxes. P/N 3101853 • REV 2.0 • ISS 21MAR11 3. Remove the gasket that comes with the 449 weatherproof box and replace it with the gasket that comes with the WG4 speaker-strobe. 4. Place the gasket over the backplate, and then feed the field wiring through the wire slots on the gasket and the backplate. See Figure 5, item 3. 5. Secure the backplate to the electrical box with four screws. 6. Connect the wiring to the terminal strip. 7. Connect the speaker to the audio NAC and the strobe to the strobe NAC. Observe polarity. See Figure 5. 8. If temporal strobe (private mode) operation is desired, cut jumper JP1. See Figure 5, item 5. 9. Set the speaker voltage. Figure 2: Protective cap 1 The default speaker voltage is 70 V. For 25 V, reposition the speaker voltage-setting switch S3. See Figure 5, item 4. 1. Protective cap Figure 3: Assembled 10. Set the candela output. The default candela setting is D. To select a different candela output, align the S2 indicator to the desired candela output. See Table 5 and Figure 5, item 1. 3 4 11. The default wattage setting is Z, corresponding to 1/4 watt. To select a different wattage, align the S1 indicator to the desired wattage setting. See Table 4 and Figure 5, item 2. 2 1 12. Remove the strobe protective cover. See Figure 2. 13. Position the cover over the backplate and secure with the six cover screws. 14. Test the unit for proper operation. Figure 1: Exploded view of assembly 1. 2. 1 Optional skirt Backplate 3. 4. Front cover Cover screws (6X) Figure 4: Mounting positions 2 3 4 5 6 1. 2. 3. 2/4 Cover screws (6X) Front cover Backplate 4. 5. 6. Optional skirt Gasket Electrical box P/N 3101853 • REV 2.0 • ISS 21MAR11 Figure 5: Wiring, JP1, and switch locations SPKR SPKR + STROBE STROBE + SPKR SPKR + STROBE STROBE + 5 1 2 4 Detail A 3 1. 2. 3. Wire slot. S1 wattage-setting switch (see Table 4). S2 candela-setting switch (see Table 5). 4. 5. JP1 strobe temporal mode selection jumper. S3 speaker voltage-setting switch. UP position is 70 V (default); DOWN position is 25 V. Note: Polarity shown in alarm condition Maintenance Table 3: Compatible synchronization sources models This unit is not serviceable or repairable. Should the unit fail to operate, contact the supplier for replacement. Perform a visual inspection and an operational test twice a year or as directed by the local authority having jurisdiction. Name Number Auto-Sync Output Module SIGA-CC1S GSA-MCC1S GSA-CC1S SIGA-CC2A SIGA-MCC1S SIGA-MCC2A Genesis Signal Master Remote Mount ADTG1M-RM MG1M-RM G1M-RM EG1M-RM Caution: Do not change the factory-applied finish. Table 4: Sound level output (dBA) Specifications Wattage Setting 25 V 70 V 2W T 90.0 89.7 Operating voltage Speaker Default Strobe 1W X 87.1 86.9 25 VRMS or 70 VRMS, switch selectable 70 VRMS 24 VDC, 24 VFWR nominal 1/2 W Y 84.0 83.9 1/4 W Z 80.8 80.8 Supervisory voltage 30 V max. dBA = Decibels, A-weighted. Sound level output See Table 4 Speaker response 400 to 4,000 Hz UL 1480: Sound level output at 10 ft. (3.05 m) measured in a reverberant room using 400 to 4,000 Hz band-limited pink noise. Strobe operating current See Table 8 Table 5: Indoor strobe output (cd) Light output Table 5, Table 6, and Figure 6 Lens Wire size 12 to 18 AWG (0.75 to 2.50 mm²) Clear UL 1971 102 123 147 161 Amber UL 1638 84 101 125 130 Compatible electrical box Wet Dry Model 449 4 in. square by 1-1/2 in. deep box Operating environment Temperature Relative humidity Wet −31 to 151°F (−35 to 66°C) 0 to 95% noncondensing P/N 3101853 • REV 2.0 • ISS 21MAR11 Standard D C B A 3/4 Regulatory information Table 6: Outdoor strobe output (cd) Lens Standard D C B A Clear UL 1638 41 50 60 65 Amber UL 1638 34 41 51 52 Table 7: UL 1638 outdoor light output Lens Manufacturer Edwards, A Division of UTC Fire & Security Americas Corporation, Inc. 8985 Town Center Parkway, Bradenton, FL 34202, USA Year of manufacture The first two digits of the DATE MFG number (located on the product identification label) are the year of manufacture. Rating (cd) Clear 233 nominal, 65 cd at −35°C Amber 188 nominal, 52 cd at −35°C Table 8: Strobe operating current in RMS (A) Setting D C B A VDC 324 390 494 495 VFWR 412 487 607 646 UL rating Regulated 24 DC, Regulated 24 FWR Synchronization Meets: UL 1971 requirements [1] North American standards Meets: UL 1971 [1], UL1638, UL1480 Follow: NFPA 72 FCC compliance This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Industry Canada compliance This Class A digital apparatus complies with Canadian ICES-003 Figure 6: UL 1971 minimum light output (% of rating vs. angle) 1 - 25 - 20 - 15 - 10 - 5180 - 30 0 - 35 - 40 - 55 - 60 - 65 - 70 10 15 20 [1] Only models with a clear lens meet UL 1971. 25 35 40 140 - 45 - 50 5 30 160 Contact information 45 120 50 55 100 For contact information see: www.utcfireandsecurity.com. 60 80 65 70 60 - 75 75 40 - 80 - 85 80 20 85 - 90 90 2 1. 2. Angle Percentage of rated output Note: Horizontal plot 4/4 P/N 3101853 • REV 2.0 • ISS 21MAR11