Trident® TRN SERIES Three-Phase Systems - 40 - 120KVA Catalog Number Comments FEATURES Application The Trident TRN Series offers quiet reliable operation for commercial office applications yet is rugged enough for manufacturing environments. The ability to support three-phase AC power improves load efficiency, allows output load balancing and easy building electrical system integration. Precisely controlled system output is suitable for any lighting or critical life safety load up to the full rated output capacity. Technical support is available from a nationwide network of factory-trained technicians. Operation AC output provides full lumen output for emergency lighting loads in commercial or industrial applications. Uninterruptible “no break” transfer provides seamless switching from normal to emergency AC power. “Double conversion” design completely isolates the line from the load, eliminating the impact of line disturbances and providing more precise output load regulation. Construction Electronics and battery cabinets constructed of heavy duty steel, with a black powder coat painted finish. All bolt-on cabinets are equipped with casters and leveling feet. All necessary power cables and control wiring harness are included. Front access battery trays provided for easy maintenance. Top and bottom cable entry provided. Compliances UL Listed to Standard 924 (Emergency Lighting) NFPA 101 (Life Safety Code) NFPA 70 (National Electrical Code) Warranty Unit: 1 Year Batteries: 10 Years (1 year full, 9 year pro-rata) Factory start-up supplied standard with all TRN series inverters. ORDERING GUIDE TRN Model Input Voltage 208¹208VAC 480480VAC 1 Only available with 208VAC output voltage. Input Conductor Capacity 3 3 Wire 4040KVA/36KW 6060KVA/54KW 8080KVA/72KW 100100KVA/90KW 120120KVA/108KW Output Voltage 208208VAC 480480VAC Options IRB RSP SFK EXP FTR OWC 485 Intel Slot Relay Board Remote Status Panel Seismic Floor Kit Export Package Certified Factory Test Report Open Communications Web Card Open Communications 485 Card Trident® TRN SERIES Three-Phase Systems - 40 - 120KVA SPECIFICATIONS Input Voltage: 208 or 480VAC, 3-wire plus ground Voltage Distortion: For linear loads, 1% THD. Less than 5% THD for 100% nonlinear loads without kVA/kW derating Voltage Range: +15%, -20% of nominal without derating Phasing Balance: 120° ±0.5° for balanced load; 120° ±1° for 100% unbalanced load Frequency Range: 60Hz., +6,-3Hz Frequency Regulation: ±0.05% Current Distortion: < 3% maximum reflected THD at full load Load Power Factor Range: 0.70 lagging to 1.0 leading without derating Current Limit: 140% of nominal AC input current maximum Overload: 125% of full load for 10 minutes; 150% for one minute, with true sinusoidal waveform Power Factor Range: > 0.99 lagging at full load. > 0.98 lagging at half load. General Operating Temperature Range: Electrical Cabinet: 0°C to 40°C (32°F to 104°F) Battery Cabinet: 20°C to 30°C (68°F to 86°F) Protective Circuitry: Transient surge (IEC 61000-4-5), LVD, short circuit, current limiting, overload and brown-out Output Voltage: 120/208, 277/480VAC, 3-wire plus ground or 4-wire plus ground Voltage Adjustment Range: ±5% Relative Humidity: 0-95% non-condensing Operating Altitude: Up to 6,600 ft. (2,000m) without derating Voltage Regulation: ±1.0% for balanced load, ±2.0% for 100% unbalanced load Acoustical Noise: Less than 63 dBA typical Dynamic Regulation: ±5.0% deviation for 100% load step; ±1% for loss or return of AC input Transient Response Time: Recover to ±2% of steady state within 1 cycle SITE PLANNING DATA Battery UPS AC AC Input Rating Voltage Current Nom. Max. kVA kW Input Output Nom. Max. OCPD VDC Discharge Current Nom. Rec. OCPD 40 36 480 208/120 48 60 80 480 106 111 150 4 A 142.2x38.8x78.7 11.244 15,000 40 36 480 480/277 48 60 80 480 106 48 60 4 A 142.2x38.8x78.7 11,233 15,200 40 36 208 208/120 114 142 200 480 106 111 150 5 B 164.7x38.8x78.7 12,547 19,400 60 54 480 208/120 71 89 125 480 157 167 225 4 A 142.2x38.8x78.7 13,324 19,600 AC Output Mechanical Data No. of Cabinets Cabinet Config. Dimensions - WxDxH inches Weight Ibs. Heat Dis BTU/hr 60 54 480 480/277 71 89 125 480 157 72 100 4 A 142.2x38.8x78.7 11,313 20,100 60 54 208 208/120 168 210 300 480 157 167 225 5 B 164.7x38.8x78.7 14,627 26,300 80 72 480 208/120 94 118 150 480 208 222 300 5 C 188.8x38.8x78.7 18,306 28,000 80 72 480 480/277 94 118 150 480 208 96 125 5 C 188.8x38.8x78.7 18,295 28,100 80 72 208 208/120 222 277 350 480 208 222 300 6 D 211.3x38.8x78.7 19,609 38,500 100 90 480 208/120 117 147 200 480 258 278 350 6 E 235.4x38.8x78.7 23,960 29,500 100 90 480 480/277 117 147 200 480 258 120 150 6 E 235.4x38.8x78.7 23,940 29,950 100 90 208 208/120 278 348 450 480 258 278 350 7 F 257.9x38.8x78.7 25,316 39,400 120 108 480 208/120 140 175 225 480 307 333 450 6 E 235.4x38.8x78.7 24,440 36,450 120 108 480 480/277 140 175 225 480 307 144 200 6 E 235.4x38.8x78.7 24,420 36,600 416 600 480 307 333 450 7 F 257.9x38.8x78.7 25,796 50,800 120 108 280 208/120 333 NOTES FOR SITE PLANNING DATA: 1. Input and bypass cables must be run in separate conduit from output cables. 2. Minimum-sized grounding conductors to be per NEC 250-122. Parity-sized ground conductors are recommended. Neutral conductors to be sized for full capacity per NEC 310-15(B)(4). References are per NEC 2008. 3. Wiring requirements: AC Input: 3-phase, 3-wire plus ground AC Output: 3-phase, 3-wire plus ground or 3-phase, 4-wire plus ground 4. All wiring is to be in accordance with national and local electrical codes. 5. Minimum cabinet access clearance: 3 ft. (0.9m) front, 12” (343mm) overhead. 6. Top or bottom cable entry through removable access plates. Punch plate to suit conduit size then replace. 7. Control wiring and power wiring must be run in separate conduit. 8. Output voltage is from BDC output. 9. Dimensions are system dimensions including UPS, BDC and battery cabinets; BDCs are front access with single output breaker. !"#$%&'()"#*+* 10. 11. 12. 13. Weights are system weights including UPS, BDC and battery cabinets; BDCs are front access with single output breaker. Heat dissipation includes UPS and BDC transformer cabinet. Standard OCPD device in 208Vout BDCs is 450A (100-120kVA) and 300A (40-80kVA) Recommended AC input external overcurrent protection is based on 80% rated devices and maximum input current limit settings. 012*!(34#56*!"#$%& ADDITIONAL NOTES: 012*!(34#56*!"#$%&'()"#* • If site configuration includes a back-up emergency generator, it is recommended that the engine generator set be properly !"#$%&'()"#*+* !"#$%&'()"#*!* !"#$%&'()"#*,* sized and equipped for a UPS application. Generator options would typically include an isochronous governor (generator frequency regulation) and a UPS compatible regulator (generator voltage regulation). Consult generator manufacturer for required generator options and sizing. • If site configuration includes an automatic transfer switch, refer to the Power Line titled “Criteria for Application of Automatic Transfer Switches (ATS) with Uninterruptible Power Supply (UPS) Systems” publication 91K-PLT-48-02. It is also recommended that the transfer switch be equipped with auxiliary contacts for the unit’s “on generator“ current limit. Consult transfer switch manufacturer for required transfer switch options and sizing. !"#$%&'()"#*,* 012*!(34#56*!"#$%&'()"#* 34#56*!"#$%&'()"#* Cabinet Configurations Configuration A !"#$%&'()"#*+* !"#$%&'()"#*,* !"#$%&'()"#*,* Configuration B !"#$%&'()"#*!* !"#$%&'()"#*-* !"#$%&'()"#*-* !"#$%&'()"#*.* Configuration E !"#$%&'()"#*!* Configuration C !"#$%&'()"#*.* !"#$%&'()"#*/* Configuration F !"#$%&'()"#*-* Configuration D !"#$%&'()"#*.* !"#$%&'()"#*/* !"#$%&'()"#*/* Dual-Lite • www.dual-lite.com A Hubbell Lighting, Inc. brand with representatives’ offices in principal cities throughout North America. Copyright © Hubbell Lighting, Inc., All Rights Reserved • Specifications subject to change without notice. • Printed in U.S.A. 0601862D 8/16 !"#$%